Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Nov 2024
Closing Soon25 Dec 2024
Tender Amount₹ 28,00,000
Costs
EMD
₹ 56,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686213_1Tender No
8236/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender documents Including Special Conditions, Particular Specifications and Schedule of credit
BOQ Items
... More
Stretching/ restringing only ACSR conductor in position on LT overhead lines of any size, type, span length with permissible span sag and binding with pin/ shackle insulator with new aluminium binding wire not less than 2mm dia complete all as specified and directed.
1
-
-
... More
M&L for pin type insulator, porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height and 65 mm dia for 1100 volts grade complete all directed.
5
-
-
... More
M&L for loop type insulator, vitreous porcelain, white, brown or green large size, with overall dimensions 90mm x 140mm and clearance of hole 25.5mm complete all as specified and directed.
5
-
-
... More
M&L for preparation old painted surface of cement concrete poles of any size from pole coping to top of pole including struts, cross arms, clamps, etc and painting with two coats of approved colour of aluminium paint on cross-arms over one coat of aluminium red oxide primer and two coats of anti-fungal weather coat paint (apex ultima) on cement poles and numbering of poles as directed with black synthetic enamelled paint complete all as specified and directed.
50
-
-
... More
M&L for preparation old painted panels of any size to this station, top to bottom and left to right complete painting with powder coated siemens grey colour complete all as specified and directed.
20
-
-
... More
M&L for LT UG cable XLPE insulated and screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of cross-sectional area 95 Sq.mm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
100
-
-
... More
M&L for LT UG cable XLPE insulated and screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of cross-sectional area 70 Sqmm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
100
-
-
... More
M&L for LT UG cable XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 50 Sqmm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
100
-
-
... More
M&L for LT UG cable XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 35 Sqmm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
100
-
-
... More
M&L for LT UG cable XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 25 Sqmm, 3.5 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
100
-
-
... More
M&L for LT UG cable XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 16 Sqmm, 4 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
100
-
-
... More
M&L for LT UG cable XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 10 Sqmm, 2 core as per IS 7098 (Part 1) 1988, including taking down old unserviceable LT UG cable complete all as specified and directed.
500
-
-
... More
S&F in repair 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor of size 2 core x 4 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including provision of 4mm dia GI suspension wire, one twin core cable flat or circular complete all as specified and directed.
250
-
-
... More
S&F in repair 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor of size 2 core x 6 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including provision of 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and directed.
250
-
-
... More
S&F in repair 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor of size 2 core x 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including provision of 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and directed.
300
-
-
... More
S&F cable route indicator for LT Cable, cast iron material, 100mm dia, round with 5-6mm thick also paint whole plate with arrow for direction indication and, two hole for mounting (3 mm embossed letter as appropriate) with angle complete all as specified and directed.
10
-
-
... More
M&L for LT Danger notice plate of size 25x15cm, 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bone in signal red colour and fixed with MS clamps, bolts and nuts of approved size complete all as specified and directed.
10
-
-
... More
S&F synthetic rubber insulated mats 2.50 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006 (superseding IS 5424) suitable for electrical shock safety of size 2m x 1 m complete all as specified and directed.
1
-
-
... More
M&L for high density polyethylene pipes (HDPE) of 50 mm bore of pressure rating 6 kgf/cm2 for cable protection laid in trenches complete all as specified and as directed.
500
-
-
... More
M&L for high density polyethylene pipes (HDPE) of 40 mm bore of pressure rating 6 kgf/cm2 for cable protection laid in trenches complete all as specified and as directed.
600
-
-
... More
Supplying, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 400 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm thick CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangements including provision of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. Panel should be above ground level (Location MH near MT) including dismantling existing old unserviceable feeder pillar complete all as specified and as directed. The scope of work includes the following:-
1
-
-
... More
Incoming:
(i) MCCB 4 pole 415 volts AC grade 250 Amp and 25 KA rupturing capacity - 01 No.
(ii) Digital volt meter 0-500 volts square type flush pattern with 3 way selector rotary switch - 01 No.
(iii) Digital ammeter with CT Ratio 400:5 square type with 3 way selector rotary switch - 01 No.
(iv) Indicator LED type RYB set - 01 No. (Three each)
-
-
-
... More
Outgoing:
(i) MCCB 4 pole 415 volts AC grade 160 Amp and 25 KA rupturing capacity -02 Nos
(ii) MCCB 4 pole 415 volts AC grade 100 Amp and 16 KA rupturing capacity -03 Nos
(iii) MCCB 4 pole 415 volts AC grade 63 Amp and 16 KA rupturing capacity -03 Nos
(iv) MCB SPN 63 Amps rating - 01 No. (v) Street light timer - 01 No
-
-
-
... More
Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Note : All out going feeders shall be connected by cable through suitable size gland plate / glands.
-
-
-
... More
Supplying, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 400 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm thick CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangements including provision of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. Panel should be above ground level (Location Bldg No P-284 near LAO gate) including dismantling existing old unserviceable feeder pillar complete all as specified and as directed. The scope of work includes the following:-
1
-
-
... More
Incoming:
(i) MCCB 4 pole 415 volts AC grade 200 Amp and 25 KA rupturing capacity - 01 No.
(ii) Digital volt meter 0-500 volts square type flush pattern with 3 way selector rotary switch - 01 No.
(iii) Digital ammeter with CT Ratio 400:5 square type with 3 way selector rotary switch - 01 No.
(iv) Indicator LED type RYB set - 01 No. (Three each)
-
-
-
... More
Outgoing:
(i) MCCB 4 pole 415 volts AC grade 160 Amp and 16 KA rupturing capacity -02 Nos
(ii) MCCB 4 pole 415 volts AC grade 100 Amp and 16 KA rupturing capacity -03 Nos
(iii) MCCB 4 pole 415 volts AC grade 63 Amp and 16 KA rupturing capacity -02 Nos
(iv) MCB SPN 63 Amps rating - 02 Nos. (v) Street Light timer -01 No
-
-
-
... More
Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Note : All out going feeders shall be connected by cable through suitable size gland plate / glands.
-
-
-
... More
Supplying, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 250 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm thick CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangements including provision of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. Panel should be above ground level (Location near Bldg No P-530) including dismantling existing old unserviceable feeder pillar complete all as specified and as directed. The scope of work includes the following:-
1
-
-
... More
Incoming:
(i) MCCB 4 pole 415 volts AC grade 200 Amp and 25 KA rupturing capacity - 01 No.
(ii) Digital volt meter 0-500 volts square type flush pattern with 3 way selector rotary switch - 01 No.
(iii) Digital ammeter with CT Ratio 400:5 square type with 3 way selector rotary switch - 01 No.
(iv) Indicator LED type RYB set - 01 No. (Three each)
-
-
-
... More
Outgoing:
(i) MCCB 4 pole 415 volts AC grade 63 Amp and 16 KA rupturing capacity -06 Nos
-
-
-
... More
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Note : All out going feeders shall be connected by cable through suitable size gland plate / glands.
-
-
-
... More
Supplying, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 200 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm thick CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangements including provision of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. Panel should be above ground level (Location near main pump house) including dismantling existing old unserviceable feeder pillar complete all as specified and as directed. The scope of work includes the following:-
1
-
-
... More
Incoming:
(i) MCCB 4 pole 415 volts AC grade 160 Amp and 36 KA rupturing capacity - 01 No.
(ii) Digital volt meter 0-500 volts square type flush pattern with 3 way selector rotary switch - 01 No.
(iii) Digital ammeter with CT Ratio 400:5 square type with 3 way selector rotary switch - 01 No.
(iv) Indicator LED type RYB set - 01 No. (Three each)
-
-
-
... More
Outgoing:
(i) MCB three pole 415 volts AC grade 63 Amp capacity -03 Nos
(ii) Star delta starter 15 KW/20HP motor-03 Nos
-
-
-
... More
Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Note : All out going feeders shall be connected by cable through suitable size gland plate / glands.
-
-
-
... More
Supplying, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 400 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm thick CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangement including provision of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. Panel should be above ground level (Gas store location) including dismantling existing old unserviceable feeder pillar complete all as specified and as directed. The scope of work includes the following:-
1
-
-
... More
Incoming:
(i) MCCB 4 pole 415 volts AC grade 250 Amp and 25 KA rupturing capacity - 01 No.
(ii) Digital volt meter 0-500 volts square type flush pattern with 3 way selector rotary switch -01 No.
(iii) Digital ammeter with CT Ratio 400:5 square type with 3 way selector rotary switch - 01 No.
(iv) Indicator LED type RYB set - 01 No (Three each)
-
-
-
... More
Outgoing:
(i) MCCB 4 pole 415 volts AC grade 160 Amp and 16 KA rupturing capacity - 02 Nos
(ii) MCCB 4 pole 415 volts AC grade 100 Amp and 16 KA rupturing capacity - 01 No
(iii) MCB SPN 63 Amps - 04 Nos
-
-
-
... More
Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Note : All out going feeders shall be connected by cable through suitable size gland plate / glands.
-
-
-
... More
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to galvanised earth lead of GI strip of size 32x6mm by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 50mm bore from earth plate to Panel/DBs and water pipe 20mm bore GI medium grade raised up to a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with handle, 20 mm bore GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/ loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed, including taking down existing unserviceable earthing complete all as specified and directed.
15
-
-
... More
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed.
297
-
-
... More
Excavating in trenches, not exceeding 1.5 m wide and exceeding 1.5 meter but not exceeding 3.00 metre depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and getting out in soft/ loose soil complete all as specified and directed.
0.64
-
-
... More
Returning, filling in, riddled soil including spreading leveling, watering and well ramming in layers not exceeding 25cm using soil obtained from excavation after the pipes/ fittings are laid/ fixed jointed and tested complete all as specified and directed.
206
-
-
... More
Removing excavated soil material from site to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr from the starting point complete all as specified and directed.
81.81
-
-
... More
M&L for PCC (1:3:6) type C-2 with using 40mm graded stone aggregate as in foundation of steel tubular poles and stay with necessary form work as required complete all as specified and directed.
5
-
-
... More
M&L for PCC (1:2:4) type B-1 with using 20mm graded stone aggregate as in coping of steel tubular poles with necessary form work as required complete all as specified and directed.
2.8
-
-
... More
S&F in repair to RYB indicator lamp as required in various panel complete all as specified and directed.
2
-
-
... More
S&F in repairs Ammeter/Voltmeter same as per existing, required in various panels complete all as specified and directed.
2
-
-
... More
S&F sintex terminal box for street light connections with 6 Amps MEC, lugs complete all as specified and directed.
32
-
-
... More
Taking down copper/ aluminium point wiring (light, fan, bell socket or power etc) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials from site after accounting in credit schedule and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
237
-
-
... More
Taking down main switches, DBs with sheet metal enclosure 4/ 8 way SPN/ TPN with MCBs, MCCBs, etc complete all as specified and directed.
14
-
-
... More
M&L for point wiring complete for one light point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multistranded, copper conductor through PVC casing and capping 20/ 25 mm size with accessories with modular metal flush boxes of suitable size & modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provision of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade, multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as specified and directed.
NOTE: Cost of modular metal flush boxes concealed in wall with suitable white cover plate for mounting switches/ sockets, regulators, bell push etc and cost of cutting chases & making good to disturbed surface with cement mortar, if required any shall be deemed to be included in the quoted rate.
100
-
-
... More
All as per SI item No. 41.00 here-in-before, but for One fan point controlled by one way switch complete all as specified and directed.
20
-
-
... More
All as per SI item No. 41.00 here-in-before, but for One exhaust fan point controlled by one switch complete all as specified and directed.
12
-
-
... More
All as per SI item No. 41.00 here-in-before, but for One 3 pin socket outlet, 5 Amps, Single pole one way on the same board with other switches including continuous 1.5 Sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly complete all as specified and directed.
15
-
-
... More
All as per SI item No. 41.00 here-in-before, but for one switch socket outlet, 15 Amp on independent board with 4.00 Sqmm unsheathed stranded 1100 Volt grade complete with 2.5 sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly complete all as specified and directed.
20
-
-
... More
All as per SI item No. 41.00 here-in-before, but for One 3 pin socket outlet, 5 Amps, independent complete all as specified and directed.
60
-
-
... More
All as per SI item No. 41.00 here-in-before, but for One bell/ buzzer point controlled by one push button complete all as specified and directed.
10
-
-
... More
S&F switch piano, flush type single pole, one way 6 Amp complete all as specified and directed.
132
-
-
... More
S&F Switch socket combination multi purpose 5 pin, 5 Amp, flush type complete all as specified and directed.
75
-
-
... More
S&F Switch socket combination 2 in 1, 3 pin 6 Amp and 3 pin 16 Amp flush type universal complete all as specified and directed.
20
-
-
... More
S&F Bell push, flush type, 5 Amp, single pole 230 volts one way complete all as specified and directed.
10
-
-
... More
S&F in repairs switch piano, flush type single pole, one way 5/6 Amp complete all as specified and directed.
200
-
-
... More
S&F in repairs bell push, flush type, 5 Amp, single pole, 230 volts one way complete all as specified and directed.
100
-
-
... More
S&F in repairs switch socket combination multi purpose 5 pin, 5/6 Amp, flush type complete all as specified and directed.
150
-
-
... More
S&F in repairs switch socket combination 2 in 1, 3 pin 6 Amp and 3 pin 16 Amp flush type universal complete all as specified and directed.
100
-
-
... More
S&F in repairs socket outlet, multipurpose, 3 pin 6 Amp and 3 pin 16Amp , 2 in 1 modular type complete all as specified and directed.
100
-
-
... More
S & F in repairs modular switch 1 way 16A, 240 volts, 1 module complete all as specified and directed
25
-
-
... More
S&F in repair modular bell push, 6 Amp, 240 Volts, 1 module complete all as specified and directed.
10
-
-
... More
S&F in repairs modular fan step regulator, 120W - 2 module, 240 Volts, 50 Hz suitable for ceiling fan any sweep complete all as specified and directed.
10
-
-
... More
S & F in repair modular socket outlet, 6A, 240 volts, 2/3 pin combined 2 module, flush type all as specified and directed.
20
-
-
... More
S&F in repairs modular socket outlet 6Amp/16Amp, 240 Volts, 2/3 pin combained 2 module flush type complete all as specified and directed.
15
-
-
... More
S&F ceiling fan regulator rotary type 120 watts complete all as specified and directed.
20
-
-
... More
S&F in repairs ceiling fan regulator rotary type 120 watts complete all as specified and directed.
100
-
-
... More
Supply and fix ceiling rose surface backelite three terminal complete all as specified and directed.
50
-
-
... More
S&F calling bell, AC, 230 volts, single pole complete all as specified and directed.
10
-
-
... More
S&F distribution board made out of sheet metal enclosure (CRCA sheet powder coated), dust and vermin proof, double door, for enclosing/ fixing MCCB, TPN 4 way, 415 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urethane (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing complete all as specified and directed.
2
-
-
... More
S&F MCCB, triple pole and neutral (four pole), 100 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and directed.
1
-
-
... More
S&F MCCB, triple pole and neutral (four pole), 63 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and directed.
1
-
-
... More
S&F distribution board made out of sheet metal enclosure (CRCA sheet powder coated) dust and vermin proof, double door, for fixing enclosing/ fixing MCB, SPN 8 way, 415 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urethane (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing complete all as specified and directed.
12
-
-
... More
S&F MCB single pole 6 to 32 Amps current carrying capacity 10 KA rating, 240 volt, C curve with IP-20 protected terminals including contact indication window, IP-20 protection, energy limitation Class-3, airflow channels on both sides, bi-connect terminals etc., complete with connection, testing and commissioning complete all as specified and directed.
72
-
-
... More
S&F MCB single pole and neutral 32 Amps, current carrying capacity 10 KA rating, 240 volt, C curve with IP-20 protected terminals including contact indication window, IP-20 protection, energy limitation Class-3, airflow channels on both sides, bi-connect terminals etc., complete with connection, testing and commissioning complete all as specified and directed.
12
-
-
... More
S&F MCB single pole and neutral 40 to 63 Amps current carrying capacity 10 KA rating, 240 volt, C curve with IP-20 protected terminals including contact indication window, IP-20 protection, energy limitation Class-3, airflow channels on both sides, bi-connect terminals etc., complete with connection, testing and commissioning complete all as specified and directed.
24
-
-
... More
M & L for sub-main wiring with 2 runs of 6 sqmm single core PVC insulated, FRLS, unsheathed cable with stranded copper conductor, 1100 Volts grade drawn through and including PVC conduit with all fitting such as Tees, Bends, Elbows, etc., fixed surface on wall/ ceiling including 6 Sqmm multistranded PVC insulated, FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down old unserviceable sub-main wiring complete all as specified and directed.
NOTE: Two runs of 6.0 sqmm copper cables and one run of 6.0 sq mm copper cable along with white colour PVC conduit with accessories will be measured as one unit length.
80
-
-
... More
Taking down carefully existing serviceable Ceiling fan/ Wall mounted fan including removing cable end connections, etc. and removing the fan for keeping in safe custody, re-hanging the ceiling fan with down rod after rewiring including clamps, hooks, hold fasteners etc and connecting up, including making electric connection from ceiling rose or connector to fan complete all as specified and directed.
20
-
-
... More
Taking down carefully existing serviceable exhaust fan including removing cable end connections, etc. removing the fan for keeping in safe custody, re-fixing the exhaust fan connecting up after rewiring, including making electric connection from ceiling rose/ connector to fan complete all as specified and directed.
12
-
-
... More
S&F 1x 20 Watts smart extruded aluminium LED batten-tube (4ft) with higher efficacy, 220V, AC decorative box type with driver, warm/cool white (as directed by Engr-in-Charge), double sided connection, holder including LED batten tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: Bajaj Cat No. BCLAB 20W LED PS or equivalent make of Philips/Jaquar/Wipro / Osram / GE / Havells / HPL/ Goldmedal
80
-
-
... More
S&F in repairs 1 x 20 Watts LED batten-tube light fittings 220V, AC decorative box type with driver, holder including LED batten tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: Jaquar cat No. LGLZPCX020XC or equivalent in Philips/Bajaj/Wipro/Osram/GE/Havells/HPL/Goldmedal.
223
-
-
... More
S&F 10 watts LED light fitting mirror type with high out put diffuser 2 feet, 220 V, AC decorative type with warm/cool white (as directed by Engr-in-Charge), driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Jaquar cat No. LGLZ01X010XC or equivalent make in Philips / Bajaj / Wipro / Osram / GE / Havells / HPL/Goldmedal
20
-
-
... More
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to galvanised earth lead of GI wire of size 4 mm dia by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth GI wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade raised up to a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with handle, 20 mm dia GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/ loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed, including taking down existing unserviceable earthing complete all as specified and directed.
2
-
-
... More
S & F 4 mm dia galvanised iron or steel wire earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
50
-
-
... More
S&F in repairs sheet steel metal enclosure single pole and neutral with a two pin and earth plug and socket complete including one single pole MCB SP 20 Amp, 10KA, 240 volts complete all as specified and directed.
10
-
-
... More
S&F in repair light fitting 36 watts LED luminair, 600x600 mm size, 220 volt, AC recessed type/ ceiling type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make: Jaquar cat No. LULT02S036XW ULTIMA or equivalent make in Philips / Bajaj / Wipro / Osram / GE / Havells / HPL/Goldmedal
16
-
-
... More
S&F in repair 10 watts metal bulk head light fitting, 220 volts, AC decorative type with driver including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Jaquar cat No. LBLK02X010XN or equivalent make in Philips / Bajaj / Wipro / Osram / GE / Havells / HPL/Goldmedal
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%