Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_663985_3Tender No
8925/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Material and labour for precast PCC 1:3:6 Type C1 using 20 mm graded aggregate solid block masonry exceeding 10 Cm width(with plain or interlocking joints as directed), built in cement mortar 1:6 all as specified and as directed.
2
-
-
Material and labour for 150mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floors including necessary form work all as specified and as directed.
8
-
-
Material and labour for 15mm thick rendering on brick/concrete surfaces in CM 1:4, finished even and smooth without using extra cement complete all as specified and as directed.
8
-
-
Material and labour preparation of newly plastered wall surfaces and applying two coats of exterior emulsion (weather coat) paint over a coat of primer complete all as specified and as directed.
8
-
-
Supply and fix powder coated aluminium frame for doors/windows/ventilators minimum thickness of powder coating is 50 micron with one or more rebats etc as in wodows/ ventilatores including necessary joining cleat, glazing clips, rubber neoprene packing, handle 2 Nos in doors, hinges, snap beading etc complete all as specified and as directed. Note ACP shall be paid separately under relevant items.
5
-
-
Material and labour ACP sheet clading with PVDF colour coated exterior grade aluminium composite panel of panel of 3 mm thick using high quality adhesive tape, filling the joint with high quality sealant and fixed over structural steel frame work all as specified and as directed.
4.5
-
-
Returning, filling in soil including spreading leveling, watering and well ramming in layers n.exc.25cm thick complete all as specified and as directed.
16.5
-
-
Removing excavated material / soil to a distance n.exc 50m away and depositing where as directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed.
3.5
-
-
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 70 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
75
-
-
Supply and fix single pole and neutral enclouser with a two pin and earth plug and socket complete with and including one MCB single pole 20 Amps complete all as specified and directed.
3
-
-
Supply and fix triple pole and neutral enclouser with a three pin and earth plug and socket complete with and including one MCB TPN 63 Amps complete all as specified and directed.
1
-
-
Material and labour for Sub main wiring using two runs of single core PVC insulated cable (FR) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size non metallic rigid PVC conduit not less than 25mm dia with accessories including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 3 run of 6 sq mm PVC copper wire and One run of PVC conduit shall be measured and paid as one unit.
30
-
-
Material and labour for Sub main wiring using four runs of single core PVC insulated cable(FRLS) 6 sqmm copper conductor multi stranded and two runs of 6 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including non metallic PVC conduit pipe ISI marked of size 32 mm including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 6 run of 6 sq mm PVC copper wire and One run of PVC conduit shall be measured and paid as one unit.
10
-
-
Supply and fix VTPN 6 way distribution board, with 200 Amps bus bar,double door flush type, with IP-54 protection, isolated neutral bars, door earthing, suitable for 4P MCCB of rating 250 A as incomer (frame F1) complete with all accessories all as specified and directed by Engineer-in Charge.
1
-
-
Supply & Fix MCCB 250 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed.
1
-
-
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth Lead earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron steel protected by GI pipe 15mm bore light grade and watering pipe 20mm bore GI pipe medium grade all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
2
-
-
Material and labour for point wiring with PVC insulated unsheathed, multistranded FRLS copper conductor colour coded in and including suitable size PVC conduts with cable 4Sqmm size, 1100 volts grade, confirming to IS:694 , including single core stranded FRLS copper conductor 4 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same PVC casing and caping for one 3 pin socket outlet of 16 Amp on independent board for air conditioner point complete all as specified and directed.
4
-
-
Supply and fix Modular switch socket combination 6 pin 16A, 3 Module complete all as specified and as directed.
4
-
-
Supply and fix MCB SP 6-32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed.
10
-
-
Supply and fix MCB SPN 40 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
4
-
-
Supply and Fix Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 4 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer Double door, flush to wall complete all as specified and as directed. NOTE: MCB shall be measured and paid separately.
2
-
-
Supply and install hi-wall split type AC unit indoor/ outdoor complete with cordless remort control unit and with in built air ioniser and plasma filter for better indoor air quality with with inverter AC single phase with all accessories of capacity 2 TR, 5 star rating as per BEE norms and fixed with necessary copper pipe and MS bracket duly painted with two coats of synthetic enamel paint over a coat of primer for fixing external compressor unit all as specified and as directed.
7
-
-
Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed input supply between 170 to 250V with output stabilizer supply at 230 V with accuracy ± 2.5% of capacity 5KVA all as specified and as directed.
5
-
-
M & L for point wiring using 4 Sqmm ISI marked 1.1 KV grade single core FR LS flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors, conforming.to IS: 8130-1984 and insulation conforming to IS: 5831-1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including in PVC casing & caping, including factory made sunken, galvanized, not less than 1.00 mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction,conforming to IS: 14772- 2000 and suitable for modular cover-plates complete all as specified in IS: 732-1989 and directed.
2
-
-
Supply and install hi-wall split type AC unit indoor/ outdoor complete with cordless remort control unit and with in built air ioniser and plasma filter for better indoor air quality with with inverter AC single phase with all accessories of capacity 1.5 TR, 5 star rating as per BEE norms and fixed with necessary copper pipe and MS bracket duly painted with two coats of synthetic enamel paint over a coat of primer for fixing external compressor unit all as specified and as directed.
1
-
-
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and as directed.
1
-
-
Supply and install , testing of electric storage water heater vertical type 25 Lit 240 volts, 5 star rated with digital display, remote control with all necessary supports for fixing and accessories including connecting to electrical/plumbing connection required at site complete all specified and directed.
16
-
-
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer Double door, flush to wall complete all as specified and directed .
1
-
-
Material and labour for Sub main wiring using two runs of single core PVC insulated cable (FRLS) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 3 run of 6 sq mm PVC copper wire and One run of PVC casing caping shall be measured and paid as one unit.
40
-
-
Supply and fix energy efficient BEE 6.00, 5 star rated high speed BLDC ceiling fan with remote, air delivery 210 CFM, 1200mm sweep, including motor-blade set, downrod, shackle, assembly kit, canopy , remote etc, Operating voltage 230 volt single phase complete all as specified and as directed.
84
-
-
Supply and fix Exhaust Fan of size 450 mm sweep with louvers, with metal body AC 230 V, 50 Hz, 1400 RPM and connecting to ceiling rose terminals with 23/.0076 flexible cable and making good the disturbed surface to match with existing finishes complete all specified and directed.
2
-
-
Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set as per specification, motor TEFC type, 2880 RPM, 415 V, 50 Hz, 3 phase, class 'F' insulation, IP55 protection, 3 HP, starting on suitable DOL/Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller(as per manufacturer), carbon steel shaft with common base frame (fabricated, mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation bolts, nuts etc. complete with antivibrator pad as required capable of discharging discharging not less than 200 LPM at 30 mtr head inclusive of suitable rated three phase starter as recommented by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer- in-charge.
2
-
-
Supply , install, testing and commissioning of outdoor compact Substation with CRT Type transformer, 11000/433 volts, 50 Hz, 3 phase, 4 wire, copper wound distribution transformer, 100 KVA capacity, vector DYn11, off load taping from +5% to -5% in step of 2.55, Class "F" insulation, Impulse withstand voltage (HV) is 75KV (Peak), Power frequency withstand voltage (HV/LV) 28kV(rms), earthing terminals including HV and LV side cable box suitable for XLPE cable with WTI scanner and limit switch for all hinged doors complete power/ control wiring all other standard fittings and accessories conforming to IS:2026/ IS 11171, % impedence : As per IS and all as specified and as directed. Including following switchgears : HT side : 11KV load break and fault make switch, 630Amps 26.3 kA for 1 sec with interlock between SFU & earth switch. Interconnection between HT switchgear and transformer shall be using 1Cx 3x 95 Sqmm . Aluminium unarmoured XLPE
1
-
-
LT side: PANEL -400 Amps Aluminium Busbar (For phase and neutral 100 % , Incomer: 250 Amps 433V 4P, 35KA MCCB with microprocessor release including O/C, S/C & E/F protection, LED type indicating lamps- R,Y, B Phase and ON-OFF-TRIP, multifunctional Meter with Class - 0.5 accuracy. Outgoing: 160 Amps 415 Volts 4p 25 KA molded case Circuit Breaker (MCCB) with adjustable Thermal and magnetic Based over current & short circuit fault Protection - 01 No, 100 Amps 415V 4P 25 KA molded case circuit Breaker(MCCB) with adjustable Thermal and magnetic Based over current 7 short circuit fault protection - 02 Nos. NOTE : (i) Necessary foundation for installation of the transformer shall be provided as per manufacturer recommendation.
(ii) Loading, unloading shifting of the transformer carefully from factory to the site by means of truck/ crane is the responsibility of the contractor. Alteration If any required in the existing structure/ route of shifting to install the transformer at site shall be caried out by the contractor, the same will be making good so as to match with the existing structure and surface and the cost deemed to be included in the items rate quoted.
-
-
-
Supply , installation , testing & commissioning of 11KV RMU, 630A, 21kA, Motor operated, Compact, Outdoor, Both side Extensible, Non drownout type, +Dc (01 No. direct switch as incomer and 1no. Load Break switch (OD) as outgoing) SAFEPLUS compact gas insulated Ring main Unit, all live parts enclosed in a robotically welded stainless steel tank of IP 67 class of protection with battery, Battery Charger and 1No. FPI, complete all as specified and as directed.
1
-
-
Supply ,fabrication and asembling of cubicle type, floor mouting totally enclosed outdoor weather proof powder coated CRCA sheet steel enclosure for Metering panel with provision for mounting 3 no. 11KV Resin cast Indoor type single phase CTs, 1No 11KV/110KV resin cast indoor type three phase PT, Provision for receiving 3 core 185 Sqmm 11 KV Cable, provision for mounting HT TOD Meter, test terminal blocks, space heater with thermostat, necessary control wiring etc without TOD meter. CT-PT Unit & fixing frame). complete all as specified and as directed.
1
-
-
Supply of 11KV Indoor Resin cast CT-PT Unit as per the KSEB specification 3 No. 11KV CTs of ratio : 10/5A, Class 0.2s, burden : 10VA and 1No. PT of ratio 11KV/110V, Class 0.2. burden 25VA (Make : ELPOWER) complete all as specified and as directed.
1
-
-
Supply and fixing of DLMS Trivector compatible TOD meter, 3phase 4wire 110v base mounting 0.2s class as per latest KSEB specification, complete all as specified and as directed
1
-
-
Supply, laying or passing through pipe HT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 11000 Volts grade of size 95 Sqmm 3.0 core including connecting/testing after taking out from trenches/ pole unserviceable HT UG cable complete all as specified and directed.
75
-
-
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
100
-
-
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm with all accessories complete all as specified and directed.
3
-
-
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm with all accessories complete all as specified and directed.
1
-
-
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to and including GI earth strip 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanized iron steel protected by GI pipe 15mm bore light grade and watering pipe 20mm bore GI pipe medium grade all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
10
-
-
Supply and fixing galvanised steel water tubing medium grade 50 mm bore including all necessary fittings such as bends, L bows, short piece connections, backnuts, caps plugs, unions couplings, flanges, sockets etc, laid in trenches including inter connection between buildings/pumps/pump houses and taking out old existing GI tubing complete all as specified and as directed.
18
-
-
Material and Labour for laying 75 mm dia HDPE double wall corrugated(DWC) pipe for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc complete all as specified and directed.
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%