Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 68,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Day To Day Maintenance Repairs To External Water Supply,external Electric Supply, Dg Sets, Lighting Protection System,security Street Lights Etc At Cgae Nedumbassery Under Ge (i) (cg) Kochi
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683312_2Tender No
8985/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for providing dry screened river sand as in sand cushioning to under ground cable including punning down of sand by layer complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
20
-
-
... More
Supply and lay unreinforced precast cable cover size 250X150X40 mm LV1 complete all as specified and as directed.
3500
-
-
... More
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 95 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
200
-
-
... More
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 70 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
150
-
-
... More
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
150
-
-
... More
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size35 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
150
-
-
... More
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 25 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
150
-
-
... More
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 16 Sqmm 4 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
300
-
-
... More
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 10 Sqmm 4 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
300
-
-
... More
Material and Labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
60
-
-
... More
Supply & Fix in replacement of MCCB 63 Amps,4 pole, 415 Volt adjustable type with breaking capacity 16 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed.
Make: Havells/ L&T / Legrand
10
-
-
... More
Supply & Fix in replacement of MCCB 100 Amps,4 pole, 415 Volt adjustable type with breaking capacity 16 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed.
Make: Havells/ L&T / Legrand
10
-
-
... More
Supply & Fix in replacement of MCCB 160 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed.
Make: Havells/ L&T / Legrand
8
-
-
... More
Supply & Fix in replacement of MCCB 200 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed.
Make: Havells/ L&T / Legrand
4
-
-
... More
Supply & Fix in replacement of MCCB 400 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed.
Make: Havells/ L&T / Legrand
4
-
-
... More
Supply and fix in repair aluminium strip 25mmx3mm complete with saddles epoxy base and fixing screws for fitting the strip all as specified and directed.
150
-
-
... More
Supply and fix in repair for earth contunity conductor of size 32x6mm GI strip all as specified and directed.
150
-
-
... More
M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer incl routine testing after filtration for any capacity of transformers/AVR/CT/PT units all as directed. (Note : The contractor shall change the filter assy before starting the filtration of transformer / AVR in presence of Engr In charge)
Note:- (i) Test results before and after filteration shall be submitted on completion in tripilicate. (ii) Necessary electric for filtration plant shall be issued by department,required length of cable/switch etc shall be arranged by the contractor.
300
-
-
... More
Supply and filling of fresh transformer power oil of BDV not less than 60 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration or for replacement complete including removing of old unservicable transformer oil into conservator tank/body tank of transformer as per IS-335 2018 complete all as specified and diredcted.
Note:- 1. The taransformer oil for topping up shall beof Di-electric strength more than 60 KV for 1 miniute at 2.5 mm gap between the two electrodes.
2. Oil shall be supplied at site in sealed barrel.
80
-
-
... More
Taking down existing street light fittings fitted at any type of pole and Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete including connection twin core copper wire drawn through rigid PVC pipe not less than 20 mm dia from junction box to light fitting complete all as specified and directed.
Note :-1. Rate of the LED light fitting includes LED light fitting, conncection twin core copper wire of suitable size, rigid PVC pipe not less than 20 mm dia and all accessories required to fit the light at any type of pole.
2. GI bracket is not included in the quotated rate.
60
-
-
... More
Taking down existing unserviceable terminal box and S & F hot pressed moulded SMC junction/terminal box of internal diemension of 200x140x95 mm and hinged door,including 01 No 4 way connector 415 Volt, 63 Amp, made out of polycorbanate or bakelite and 1 No. MCB of 6 Amp with DIN bar,drilling holes for cable connections connecting incomming and or out going cables by providing cable luggs/glands of suitable size fixed on pole by means of clamps made out of MS flat iron of suitable sizes,duly painted with two coats of red oxide zince primer complete all as specifiedand directed. Make : Sintex/L&T/Havells or equivalent
30
-
-
... More
Supply and fixing in repairs of Omni-directional, elevated,Taxiway edge light with Blue 5Watt LED and blue lens,including electronic convertor, breakable coupling, base plate,secondary lead,set of SS bolt /washer set with suitable lamp and holder and suitable to operate with 2.8 Ampnto 6.6 Amp power source and cable coonnection from transformer to light fitting complete as per FAA L-823, including testing and commissioning all as per ICAO standards and as directed at site. Make:Havells/Polycab/Finolex/ICC/Unistar/NICCO/Asian/CCI/Gloster
20
-
-
... More
Supply and fixing in repairs cable single core 6 Sqmm, 5KV grade , PVC insulated, PVC sheathed, unarmoured stranded copper conductor as per IS-1554 Part-II as amended upto date laid in trenchs/floor/wall/drawn through pipes/conduits etc. complete including testing and commissioning all as per ICAO standards and as directed at site.
Make: Havells/Polycab/Finolex/ICC/Unistar/NICCO/Asian/CCI/Gloster
250
-
-
... More
Supply and fixing in repairs/replacement for series type Isolating Transformer 15W, 6.6/6.6 Amps, 5 KV grade, 50 Hz, moulded with neoprene type rubber with primary and secondary connectors for elecated type light fitting complete including testing and commissioning all as per ICAO standards and as directed at site.
Make: Bildal/Vajra Transformers Pvt Lmt/Truetech Products/Insel Rectifiers India or equivalent
5
-
-
... More
Cleaning and preparation of old painted surface of steel pole 11 mtr long excluding planting depth complete and painting with one coat of aluminium paint and making black and white strips with synthetic enamel paint 30 cm height, each alternative strips ,up to 1.5 mtr height and writing pole Nos and applying one coat of cement base paint on PCC coping complete all as specified and as directed.
30
-
-
... More
M & L for painting the outer surface of the transformer with two coat of greenovoc water based polymer paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 100 KVA to 600 KVA (Indoor/outdoor type).
1
-
-
... More
M & L for painting of HT/LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun all as directed.
6
-
-
... More
Supply and fix LED bollard light with pole 10 watt, 240 volt with aluminium body pressure die cast powder coated housing with PC diffuser IP-65 protection with inbuilt LED chip and driver, accessories prewired and fixing accessories complete all as specified and directed. Make: 824.075L10H.NHG of Jaquar or equivalent in Crompton Greaves/ Havells/Philips.
32
-
-
... More
Supply, fixing, laying & testing galvanised iron water tubing of 25 mm dia, medium grade, ISI marked with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches/floor including taking out unserviceable pipe, complete all as specified and directed:-
400
-
-
... More
Supply, fixing, laying & testing galvanised iron water tubing of 40 mm dia, medium grade, ISI marked with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches/floor including taking out unserviceable pipe, complete all as specified and directed:-
160
-
-
... More
Supply and fixing Unplasticised PVC pipes of pressure rating 10 kg/cm2 fixed complete to walls, trenches or in floors etc. 25 mm bore including taking down old unserviceable pipe complete all as specified and as directed.
300
-
-
... More
Supply and fixing Unplasticised PVC pipes of pressure rating 10 kg/cm2 fixed complete to walls, trenches or in floors etc. 40 mm bore including taking down old unserviceable pipe complete all as specified and as directed.
300
-
-
... More
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed.
20
-
-
... More
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25 mm bore complete all as specified and directed.
20
-
-
... More
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 40 mm bore complete all as specified and directed.
6
-
-
... More
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 50 mm bore complete all as specified and directed.
4
-
-
... More
Taking out old unserviceable Foot valve and supply and fixing new CI Foot valve 50mm dia approved make including jointing complete all as specified and directed at site.
4
-
-
... More
Taking out old unserviceable Foot valve and supply and fixing new CI Foot valve 80mm dia approved make including jointing complete all as specified and directed at site.
4
-
-
... More
Supply and fix in repairs Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 20mm bore complete all as specified and as directed.
25
-
-
... More
Supply and fix in repairs Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 25mm bore complete all as specified and as directed.
25
-
-
... More
Material and Labour for cleaning underground sump of 50000 Ltrs capacity by draining/ pumping out complete water from sump, cleaning with wire brush for removing scales, algae etc from inside and removing silt accumulated at the bottom of the sump, flushing out , washing of inner surface using lime and bleaching powder and clean water with the help of pump or drain out as required, applying a coat of white wash for all surfaces of the UG sump from inside, painting and writing the date of cleaning and capacity etc in bold letters complete all as specified and directed.
2
-
-
... More
Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etc through drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleaned yearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakages of tank of capacity 1000 Ltrs. complete all as directed.
Note: Tank shall be cleaned yearly as directed by Engineer-in-Charge.
14
-
-
... More
Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etc through drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleaned yearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakages of tank of capacity 750 Ltrs. complete all as directed.
Note: Tank shall be cleaned yearly as directed by Engineer-in-Charge.
13
-
-
... More
Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etc through drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleaned yearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakages of tank of capacity 500 Ltrs. complete all as directed.
Note: Tank shall be cleaned yearly as directed by Engineer-in-Charge.
14
-
-
... More
Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etc through drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleaned yearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakages of tank of capacity 250 Ltrs. complete all as directed.
Note: Tank shall be cleaned yearly as directed by Engineer-in-Charge.
4
-
-
... More
Repair works to submersible motorpump set having capacity 7.5HP 3 phase 415 volts, shifting to the civil workshop for removing of burnt windings, bearing etc, including cleaning the slots, rewinding with new stove enamelled copper wire as per existing size, including changing of bearings, etc , and installation, testing complete as per manufacturer's instruction with entire satisfaction of Engr-in-charge. Note- Rate quoted shall be inclusive of cost of spares as required for repair work.
1
-
-
... More
Repair works to submersible motorpump set having capacity 5HP 3 phase 415 volts, shifting to the civil workshop for removing of burnt windings, bearing etc, including cleaning the slots, rewinding with new stove enamelled copper wire as per existing size, including changing of bearings, etc , and installation, testing complete as per manufacturer's instruction with entire satisfaction of Engr-in-charge. Note- Rate quoted shall be inclusive of cost of spares as required for repair work.
1
-
-
... More
M/L for Maintenance and servicing of standby DG Set 100 KVA complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleaner , change air cleaner elements, check coolant level & make up the same ,drain the fuel filter & water separator ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, including M & L for V Belts, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load and record shall be made in respect of RPM , oil pressure ,oil temperature ,coolant temperature, voltage , frequency , load current , battery charging , fuel consumption etc complete all as specified and directed by Engineer in Charge for 100 KVA DG set.Make: Kirloskar. Details of DG sets: (a) 100 KVA DG Set
1
-
-
... More
Note :- 1
(a). Engine oil for refilling will be measured and paid for separately (b). Coolant for make up will be measured & paid for separately
(c). Testing will be carried out in presence of Engineer - in - charge and DHPP consumption will be entered in PRRB. (d). The Make of Fuel filter , Oil Filter , V belt & component will be as per manufactures recommendations ( Rate of fuel filter, oil filter, air filter and V belt shall deem to be included in quoted rate.)
-
-
-
... More
(e) Charges for Major repairs / top overhauling of engine, rewinding of alternator, alternator major overhauling due to normal wear & tear will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of DG set and Control panel shall be deemed to be included in the rate quoted.
(f) U/s spares shall be measured under Schedule of Credit.
-
-
-
... More
M/L for Maintenance and servicing of standby DG Set 400 KVA complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleaner , change air cleaner elements, check coolant level & make up the same ,drain the fuel filter & water separator ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, including M & L for V Belts, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load and record shall be made in respect of RPM , oil pressure ,oil temperature ,coolant temperature, voltage , frequency , load current , battery charging , fuel consumption etc complete all as specified and directed by Engineer in Charge for 400 KVA DG set.Make: Kirloskar. Details of DG sets: (a) 400 KVA DG Set
1
-
-
... More
Note :- 1
(a). Engine oil for refilling will be measured and paid for separately (b). Coolant for make up will be measured & paid for separately
(c). Testing will be carried out in presence of Engineer - in - charge and DHPP consumption will be entered in PRRB. (d). The Make of Fuel filter , Oil Filter , V belt & component will be as per manufactures recommendations ( Rate of fuel filter, oil filter, air filter and V belt shall deem to be included in quoted rate.)
-
-
-
... More
(e) Charges for Major repairs / top overhauling of engine, rewinding of alternator, alternator major overhauling due to normal wear & tear will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of DG set and Control panel shall be deemed to be included in the rate quoted.
(f) U/s spares shall be measured under Schedule of Credit.
-
-
-
... More
Supply only multi-grade 15W40 lubricating oil for DG Sets as per manufacturer’s recommendations, complete all as specified and directed. Make- IOC, Castrol, Hindustan Petroleum
120
-
-
... More
Supply only coolant for radiator as per manufacturer’s recommendations, complete all as specified and directed. Make- Castrol, Servo, Cummins
60
-
-
... More
Supply & fixing Water body,radiator system, with connecting accessories Hose pipe set , Clips of water / coolant cooled radiator system for 100 KVA DG set
1
-
-
... More
Repairs & Overhauling of radiator assembly by dismantling from engine transporting to the workshop and removing the sediments and scales, corrosion etc by means of acid, cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality material for stopping the leakage etc, re-assembling the same with new gaskets and transporting to the site, fixing to the engine with hoses, clips complete to the entire satisfaction of engineer - in - charge as required for 100 KVA DG set.
1
-
-
... More
Repairs & Overhauling of radiator assembly by dismantling from engine transporting to the workshop and removing the sediments and scales, corrosion etc by means of acid, cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality material for stopping the leakage etc, re-assembling the same with new gaskets and transporting to the site, fixing to the engine with hoses, clips complete to the entire satisfaction of engineer - in - charge as required for 400 KVA DG set.
1
-
-
... More
Dismantling the water pump of the DG Set taking out the worn out parts, refixing the water pump in the same position after replacing the worn out parts with new water pump repair kit set for 100 KVA DG set.
1
-
-
... More
Repairs to 12/24V self starter by removing, dismantling and taking it to authorised workshop and replacing unserviceable Armature including field coil tapping re-fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge
2
-
-
... More
Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for Greaves Power cotton curve of capacity 100 to 250 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge. Make : Kirloskar / Cummins/Crompton Greaves.
2
-
-
... More
Supply only Solenoled shut off valve sup and fix new Solenoled shut off valve assembly complete suitable to operate with 12/24 volts DC all as specified and as directed.
2
-
-
... More
Supply only Ignition switch heavy duty with keys for 100 KVA DG set complete all as specified and directed.
1
-
-
... More
Supply only Ignition switch heavy duty with keys for 400 KVA DG set complete all as specified and directed.
1
-
-
... More
Removing the silencer and replace with new gasket and manifold to arrest all exhaust leakage for Genset for 100 KVA DG set complete all as specified and directed.
1
-
-
... More
Supply and replacement of radiator hose of Diesel engine generating sets for 100 KVA DG set complete all as specified and directed.
1
-
-
... More
Supply and replacement of radiator hose of Diesel engine generating sets for 400 KVA DG set complete all as specified and directed.
1
-
-
... More
Supply and repalcement of fuel hose set nylon type of any capacity for 100 KVA DG set complete all as specified and directed.
1
-
-
... More
Supply and repalcement of fuel hose set nylon type of any capacity for 400 KVA DG set complete all as specified and directed.
1
-
-
... More
Supply and replacement of radiator fan belt for 100 KVA DG set complete all as specified and directed.
3
-
-
... More
Supply and replacement of radiator fan belt for 400 KVA DG set complete all as specified and directed.
2
-
-
... More
Supply and fix in repairs control unit for 100 KVA DG set complete all as specified and as directed.
1
-
-
... More
M&L for distilled water to be filled in batteries all as directed by Engr-in-Charge
10
-
-
... More
S& F in replacement of Contactor, 400 Amp, 3 pole,rated operational voltage =690 Voltage AC 50 Hz, with rated making capacity of 4000 Amp at 440 Volt AC for power circuit conformoing to IEC 60947-4-1& rated breaking capacity 3200 A at 440 volt for power circuit conforming to IEC 60947, electrical durability 600000 cycles AC-13 complete all as specified and directed.
2
-
-
... More
Dismatling and removing fuel injection pump (FIP) of capacity of 100 KVA DG Set and taking out it to authorised workshop and replacing unserviceable element, delivery valve, balance wait, lever, bearing after repairing fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge
1
-
-
... More
Dismatling and removing fuel injection pump (FIP) of capacity of 400 KVA DG Set and taking out it to authorised workshop and replacing unserviceable element, delivery valve, balance wait, lever, bearing after repairing fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge
1
-
-
... More
Disconnecting the existing battery of capacity 12V / 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge.
1
-
-
... More
Supply and fix in replacement of Dry cell tubular type 12 V , 110 - 180 AH and initial charging complete including inbuilt charger including required electrolite /distilled water etc and fixing as required at site to the concerned DG Set all as directed.Make : EXIDE
1
-
-
... More
Painting of the 100 KVA capacity DG set after preparing the external surface, apply one coat of spray painting by superior quality enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed.
1
-
-
... More
Painting of the 400 KVA capacity DG set after preparing the external surface, apply one coat of spray painting by superior quality enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed.
1
-
-
... More
Schedule of Credit (Minus) Rs.104260.00 NOTE: Bidder shall insert credit amount of Rs. 104260.00 as rate in Green field under Col-13.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%