Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 28,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_664802_1Bid Award Id
ViewTender No
8194/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender documents Including Special Conditions, Particular Specifications and Schedule of credit
BOQ Items
All as per SI item No. 2.00 here-in-before, but for one bell point controlled by one way switch complete all as specified and directed.
4
-
-
All as per SI item No. 2.00 here-in-before, One 3/5 pin 5 Amps socket outlet on independent board complete all as specified and directed.
42
-
-
All as per SI item No. 2.00 here-in-before, One 3/5 pin 5 Amps socket outlet on same board complete all as specified and directed.
23
-
-
All as per SI item No. 2.00 here-in-before, One light point controlled by two way switch complete all as specified and directed.
2
-
-
All as per SI item No. 2.00 here-in-before but with using copper conductor of 2.5 Sqmm for one 3/5 pin socket outlet 15 Amps on independent and using 1.5 Sqmm copper conductor as earth continuty cable compete all as specified and directed.
25
-
-
S&Fswitch piano, flush type single pole, one way 5/6 Amp complete all as specified and directed.
372
-
-
S&F Bell push, flush type, 5 Amp, single pole 230 volts one way complete all as specified and directed.
4
-
-
S&F switch flush type 5 Amps two way complete all as specified and directed.
4
-
-
S&F socket outlet with safety shutter 5 pin 5 Amps flush type all as specified and directed.
65
-
-
S&F switch piano flush type one way 15 Amps, Single Pole complete all as specified and directed
25
-
-
S&F socket outlet polycarbonate 2 in 1 , 3 pin 5 / 15 Amps flush type complete all as specified and directed.
25
-
-
S&F Bell Ding Dong musical AC 230 Volt complete all as specified and directed.
4
-
-
S&F for lamp holder insulated body of PVC / polycarbonate type with back plate suitable for Angle/ batten fittings complete all as specified and directed.
40
-
-
S&F ceiling rose 3 terminals PVC / Polycarbonate insulated body 65mmx 50mm size complete all as spcified and directed.
267
-
-
S&F stepped type electronics fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
42
-
-
S&F in replacement of self ballast LED batten light fittings extruded theremoplastic body with PC diffuser 120 degree wide distribution, 4 feet 20 W LED batten 4 feet 20 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified make - Bajaj cat Pt No BCLSB 20 W WH or equivalent make of Philips/Jaguar/Wipro/Osram/GE/Havells/HPL/Halonix
225
-
-
S&F in replacement of self ballast LED batten light fittings extruded theremoplastic body with PC diffuser 120 degree wide distribution, 4 feet 18 W LED batten 4 feet 20 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified and directed. Make - Bajaj Cat Pt No BCLSB 18W WH or equivalent make of Philips/Jaguar/Wipro/Osram/GE/Havells/HPL/Halonix
80
-
-
S&F in replacement of self ballast LED batten light fittings extruded theremoplastic body with PC diffuser in unique square shape 120 degree wide distribution, 2 feet 10 W of LED batten 2 feet 9 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified and directed. Make - Bajaj cat Pt No BCLSB 10 W WH or equivalent make of Philips/Jaguar/Wipro/Osram/GE/Havells/HPL/Halonix
55
-
-
S&F in replacement of LED light fitting 1x10 Watt bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete and all as specified and directed.
46
-
-
S&F in replacement bracket for street light fitting made out of 40 mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by Engineer-in-charge and fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishiung coat with alumminium paint complete all as specified and directed.
8
-
-
S&F in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
12
-
-
S&F in replacement of Recessed/Surface mounting 36W LED luminaire, prewired with white powder coated CRCA housing with LEDs and fully window acrylic diffuser, suitable for 600x600mm E-grid/POP/ false ceiling complete with all accessories making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
11
-
-
S&F in replacement submain wiring with using two single core 6.0 SQmm copper multy stranded conductor PVC insulated and unsheathed (FRLS) cable and one single core 6.0 Sqmm copper multistandred conductor PVC insulated and unsheathed (FRLS) Earth wire using ISI Marked IS 694 1100 volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade concealed PVC conduit ISI marked not less than 25 mm dia including conduit fitting and accessories complete including cutting cheses in existing wall of any descirption built in cement mortar and making good the disturbed surfaces in cement mortor (1:4) and finishing the surfaces to match with existing surfaces and finish termonatioin with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partition including clamping arrangement as required complete all as sepcified and directed .
Note:- Two Run of 6.0 Sqmm cable and one run of 6.0 sqmm earth wire in and including conduit of suuitable size shall be measured as one unit.
270
-
-
S&F in replacement of MCB SP 6-32 Amps breaking capacity 10 KA 'B' series 240 volts 50 Hz complete all as specified and directed.
65
-
-
S&F in repacement of MCB SPN 40 to 63 Amps breaking capacity 10 KA 'B' series 240 volts 50 Hz complete all as specified and directed.
15
-
-
S&F in replacement of MCB TPN 63 Amps breaking capacity 10 KA 'B' series 415 volts 50 Hz complete all as specified and directed.
8
-
-
S&F in replacement of double door MCB distribution board with steel sheet powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 8 Ways complete including and making good the distrubed surfaces of walls, floors filling up of holes, plastering, whitewashing/distembering etc matching to the existing all as specified and directed.
6
-
-
S&F in replacement of double door MCB distribution board with steel sheet powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single pole and neutral confirms to IS 13032- 1991 of 12 Ways complete including and making good the distrubed surfaces of walls, floors filling up of holes, plastering, whitewashing/distembering etc matching to the existing all as specified and directed.
2
-
-
S&F in replacemnt of TPN sheet steel, distribution board, Double Door, 4 ways confirming to IS 13032-1991 complete including and making good the distrubed surfaces of walls, floors filling up of holes, plastering, whitewashing/distembering etc matching to the existing all as specified and directed.
8
-
-
S&F in replacement of LED Lamp 15 Watt complete all as specified and directed.
40
-
-
S&F in replacement of Modular switch 6 A, 1 module, as per existing make available at site and all as specified and directed.
5
-
-
S & F in replacement of Modular switch 16 A, 1 module, as per existing make available at site and all as specified and directed.
5
-
-
S&F in replacement of modular Bell push 6A 1 module, as per existing make available at site and all as specified and directed.
3
-
-
S & F in replacement of Modular Socket 6A - 2/3 pin combined 2 module, as per existing make available at site and all as specified and directed.
5
-
-
S & F in replacement of Modular socket 6A/16A - 2/3 pin combined, 2 module, as per existing make available at site and all as specified and directed.
3
-
-
S & F in replacement of Modular ceiling fan regulator as per existing make available at site and all as specified and directed.
2
-
-
S&F in replacement and providing new Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one double pole MCB of 20 Amp ,240 Volt, 10KA complete all as specified and as directed.
3
-
-
S&F in replacement of old unserviceable and providing new Syphon assembly of 06 holes / 09 holes (ISI Marked) made out of brass of 25/35 ltr capacity geyser including necessary studs, screws and rubber gasket/washers Complete all as specified and directed.
5
-
-
S&F in replacement of old unserviceable safety valve (ISI Marked) suitable for 25 to 50 Ltrs capacity geysers Complete all as specified and directed.
6
-
-
S&F in replacement of old unserviceable heating element titanium coated of rating 1.5 Kw suitable for water heater storage type any make and type as required at site including rubber washers (ISI marked) Complete all as specified and directed.
12
-
-
S&F in replacement of old unserviceable and providing new heating element titanium coated of rating 2.0 Kw suitable for water heater storage type any make and type as required at site including rubber washers (ISI marked) Complete all as specified and directed.
11
-
-
S&F in replacement old unserviceable stainless steel water tank 1.8 mm thick with 0.7 Mpa bar pressure, suitable for geyser 25 ltr capacity complete with rubber gasket, Complete all as specified and directed.
Notes :- (i) The tank shall be tested at site and shall be able to withstand requisite pressure, necessary arragengments for the testing shall be made arranged by the contractor.
(ii) Tank with stud type and round element shall only be provided and trianguluar element shall not be accepetable.
3
-
-
S&F in replacement old unserviceable stainless steel water tank 1.8 mm thick with 0.7 Mpa bar pressure, suitable for geyser 50 ltr capacity complete with rubber gasket, Complete all as specified and directed.
Notes :- (i) The tank shall be tested at site and shall be able to withstand requisite pressure, necessary arragengments for the testing shall be made arranged by the contractor.
(ii) Tank with stud type and round element shall only be provided and trianguluar element shall not be accepetable.
3
-
-
S&F Geyser connections pipes for hot and cold water supply made of stainless steel wire braided conntector with chrome finish heavy duty nuts of 15mm size with suitable lengh including taking down of old unserviceable Geyser connection pipes complete all as specified and directed.
27
-
-
M & L for Replacement of old unserviceable thermal insulation material non hygroscopic, fire resistant, fiber glass wool for 25-50 ltrs capacity geyser complete all as specified and directed.
2
-
-
M & L for preparing the old painted steel surface by rubbing/scraping the old paint with sand paper for 25 ltrs capacity geyser and painting with two coats of synthetic enameled paint white with spray gun including writing MES Nos with black paint , of required size and shape, complete all as specified and directed.
8
-
-
M & L for preparing the old painted steel surface by rubbing/scraping the old paint of 50 ltrs capacity geyser and painting with two coats of synthetic enameled paint white with spray gun including writing MES Nos with black paint, of required size and shape, complete all as specified and directed.
4
-
-
S&F in replacement Indicator lamp (green & red ) with Neon lamps(ISI Marked) indicating automatic working of geyser round/square type suitable for geyser capacity 25/50 ltr AC 230 volt complete all as specified and directed.
3
-
-
S&F anchor bolt of size 12mm dia and 100mm long with washer including drilling holes for fixing anchor bolt and making good to the disturbed surface matching with existing surface complete all as specified and as directed.
16
-
-
M & L for Descaling of geyser of capacity 25litre /50litre from wall after unscrewing nuts/bolts etc and again refixing in position after repair works including strip opening the assembly,de-scalling the syphon assembly, steel tank and incoming and outgoing water connection complete all as specified and as directed.
4
-
-
S&F cable PVC insulated and overall sheathed copper conductor cord flexible wire, multistranded 1100 volt grade of size 2.5 sqmm, 3 core (ISI Marked) complete all as specified and as directed.
78
-
-
M&L for taking down and dismantiling out old unsv ceiling fans from site and removal of burnt winding by cutting, cleaning slots and re-winding of motor for AC celling fan of size 1200mm any make of fan with super enameled copper winding wire of existing gauge, weight above 350 grams per fan, varnishing with E class insulation varnish. threading, including neceassry laith work and connnecting with appropriate size copper conductor cable upto connector block complete all as specified and directed.
Notes:- (i) Motor shall be wound with machine only.
(ii) Rate quoted shall be deemed to be included for dismantling and taking down of any type of fans from site for necessary repair work and refixing in the same location after repair work
100
-
-
M&L for taking down and dismantiling old unsv ceiling fans from site and removal of burnt winding by cutting, cleaning slots and re-winding of motor for AC celling fan of size 1400mm any make of fan with super enameled copper winding wire of existing gauge, weight above 500 grams per fan, varnishing with E class insulation varnish. threading, including neceassry laith work and connnecting with appropriate size copper conductor cable upto connector block complete all as specified and directed.
Notes:- (i) Motor shall be wound with machine only.
(ii) Rate quoted shall be deemed to be included for dismantling and taking down of any type of fans from site for necessary repair work and refixing in the same location after repair work
35
-
-
S&F replacement of old unserviceable capacitor AC 230 volts 2.5 mfd complete all as specified and directed.
250
-
-
S&F in replacement of old unserviceable capacitor AC 230 volts 3.15 mfd complete all as specified and directed.
20
-
-
S&F in replacement of old unserviceable capacitor AC 230 volts 4.00 mfd complete all as specified and directed.
12
-
-
S&F in replacement of old unserviceable ball bearing of bearing No 6200 to 6204 including neceassry lathe grinding and welding work Complete all as specified and directed.
89
-
-
S&F in replacement of old unserviceable shackle assembly kit consist of Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos suitable for ceiling fan of 1200/1400mm sweep Complete all as specified and directed.
35
-
-
S&F in repalcement of old unserviceable mild steel down rod of ceiling fan of dia 20 mm bore "medium grade" complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) in white/brown colour (fully furnished) Complete all as specified and directed.
43
-
-
M&L for Servicing of ceiling fans of 1200/1400mm sweep any type any make including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins (02 Nos), cutter pins(02 Nos), and refixing to the existing site after servicing Complete all as specified and directed.
11
-
-
S&F in replacement of cable PVC insulated and overall sheathed with flexible copper conductor cable of size 0.5 sqmm, 3 core cut to size of approx 0.30 metre from block of fan to ceiling rose Complete all as specified and directed.
150
-
-
M&L for dismantiling and taking out old unsv Exhaust fans from site and removal of burnt winding by cutting, cleaning slots and Re-winding of the motor of exhaust fan/ Table fan/cabin fan, 250-380mm sweep any make with super enameled copper winding wire of exisiting gauge, including cuting and getting out old burnt winding, sleev work , varnish with E class insulation varnish threading, including neceassry lathe grinding and welding work complete and connections with appropriate size copper conductor cable upto connector block Complete all as specified and directed. Note :- (i) Motor shall be wound with machine only. (ii) Copper winding shall be of weight upto 300 gms.
20
-
-
All as per SI item No. 65.00 here-in-before, but for rewinding of motor of exhaust fan/ Table fan/cabin fan, 400mm-450mm sweep complete all as specified and directed.
15
-
-
M&L for Removing old paint by scraping with sand paper to remove old paint including washing and filling cavaties with filler and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray gun using spray gun method painting to ceiling fan of 1200mm sweep at site (complete 03 Nos blades, motor (both sides) including down rod, writing MES No/ Srl No on the ceiling fans Complete all as specified and directed by Engineer-In-Charge.
5
-
-
All as per SI item No. 67.00 here-in-before, but for ceiling fan of 1400mm sweep Complete all as specified and directed by Engineer-In-Charge.
5
-
-
All as per SI item No. 67.00 here-in-before, but for Exhaust fan of 400mm sweep Complete all as specified and directed by Engineer-In-Charge.
8
-
-
All as per SI item No. 67.00 here-in-before, but for Exhaust fan of 300mm sweep Complete all as specified and directed by Engineer-In-Charge.
7
-
-
M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate No-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be re-done by the contractor at no extra cost to Govt) complete all as specified and directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements