Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 32,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677373_1Bid Award Id
ViewTender No
8967/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
(c) One 3 pin socket outlet 5 Amps on same board
30
-
-
(d) One bell point controlled by one bell push
10
-
-
All as per Item No. 2 above but with 4 sq mm PVC insulated copper conductor cable(FRLS) including 4 sq mm PVC copper conductor used as earth wire for power point on independent board for One 3 pin socket outlet, 15 Amps.
20
-
-
Attending internal/ external electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in internal electric wiring/circuit, LT panels/ meter panel, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge.
Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid.
(b) The spares required for the rectification of fault shall be measured under relevent items of BOQ.
(c) Five(05) numbers of complaint shall be measured as one unit(Each Job)
400
-
-
Supply only Switch piano, flush type, single pole, one way 5 Amps, 230 volt AC with ISI marked complete all as specified and directed.
120
-
-
Supply only Socket outlet 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
90
-
-
Supply only socket outlet, 15 Amps, 3 pin flush type complete all as specified and directed.
50
-
-
Supply only switch Socket Combination 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
60
-
-
Supply only Switch Socket Combination 2 in 1, 5 Amps /16 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
50
-
-
Supply only Bell electric ding dong 230 V complete all as specified and directed.
20
-
-
Supply only Bell push, flush type, 5 Amps one way complete all as specified and directed.
20
-
-
Supply only electronic fan regulator, stepped type, flush type on the existing phenolic laminated sheet etc. complete all as specified and as directed.
30
-
-
Supply only Modular switch one way 6A, 1 Module complete all as specified and as directed.
80
-
-
Supply only Modular Switch 1 way, 16 Amps, 1 module complete all as specified and as directed.
50
-
-
Supply only Modular switch, two way, 6 Amps one module complete all as specified and directed.
15
-
-
Supply only Modular socket 6A 2/3 pin combined 2 module complete all as specified and as directed.
50
-
-
Supply only Modular Socket, 6/16 A- 2/3 pin combined 2 module complete all as specified and as directed.
40
-
-
Supply only Modular fan regulator 120 W one way , 2 Module complete all as specified and as directed.
25
-
-
Supply only Modular Bell push, 6 Amps complete all as specified and directed.
20
-
-
Supply only Modular switch socket combination 16 A 6 pin 3 Module complete all as specified and directed.
30
-
-
Supply only Modular switch socket combination, 3 pin 6A, 3Module complete all as specified and as directed.
30
-
-
Supply only Ceiling rose in poly carbonate 3 phases flush type 6 Amps, 230 volts AC complete all as specified and directed.
40
-
-
Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fitting complete all as specified and directed.
40
-
-
Supply only in replacement of Capacitor 2.5 MFD complete all as specified and as directed.
Make : Havells /L&T/Surya
50
-
-
Supply only LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Make: Bajaj / Havells/Philips/Crompton Greaves.
300
-
-
Supply only in replacement of LED bulb 9 watts, 230 volt, provides upto 4 Hrs backup 2200 mAh Li-On Battery for Longer Product Life,Protection Shield : Overcharge, Deep Discharge & Short Circuit Protection 100 Lumens Per Watt Surge Protection Upto 4Kv Voltage Protection upto 440V complete all as specified and directed. Make: Crompton Cat part No. LED9WDFINVNB4DCDL or equivalent in Philips/Bajaj/Havells.
120
-
-
Supply only LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Make: Crompton Cat part No. TCR-145-36-65-SL-NWH or equivalent in Philips/Bajaj/Havells.
15
-
-
Supply only LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Crompton/Philips/Bajaj/Havells.
20
-
-
Supply only round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Make: Crompton/Philips/Bajaj/Havells.
10
-
-
Supply only round shape12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Make: Crompton/Philips/Bajaj/Havells.
15
-
-
Supply only round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Make: Crompton/Philips/Bajaj/Havells.
15
-
-
Supply only energy efficient LED building security light fitting 35W on existing brackets including connection with twin core flexible pvc 0.5 sqmm cable complete all as specified and as directed.
Make: Crompton/Philips/Bajaj/Havells.
10
-
-
Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with one MCB single pole 20 Amps complete all as specified and directed.
6
-
-
Supply only MCB SP 6-32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed. Make: Crompton/L&T/Bajaj/Havells.
30
-
-
Supply only MCB SPN 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Make: Crompton/L&T/Bajaj/Havells.
5
-
-
Supply only TPN 63 AMP, 415V 10KA 'C' curve miniature circuit breaker (MCB) in the DB complete with connection testing and commissioning all as specified and directed. Make: Crompton/L&T/Bajaj/Havells.
8
-
-
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed.
6
-
-
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 12 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed.
5
-
-
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way, Double door, IP-30 protection (4 + 12 module) TPN MCB, 415 V as incomer, SP/DP/TP/TPN as outgoing complete all as specified and directed .
3
-
-
Material and labour for sub main wiring in replacement with two runs of FRLS single core multistranded copper conductor 4 sqmm, PVC insulated and unsheathed drawn through and including suitable size PVC casing and caping with all accessories fixed to walls/ceiling including one run of 4 Sqmm copper (insulated) cable FRLS as earth continuity conductor including complete all as specified and as directed. Note : 3 runs of 4 Sqmm cable and one run of PVC casing and caping shall be measured one unit length.
40
-
-
Material and labour for sub main wiring in replacement with 2 runs of 6 sqmm FRLS single core multistranded copper conductor PVC insulated and unsheathed drawn through and including PVC casing and caping of suitable size with all accessories such as bends,Tee, junction boxes, elbow etc fixed to walls/ceiling including 1 run of 6 Sqmm copper (insulated) FRLS cable as earth continuity conductor including complete all as specified and as directed. Note : 3 runs of 6 Sqmm copper cable and one run of PVC casing and caping shall be measured one unit length.
40
-
-
Material and Labour for Sub main wiring in replacement using 4 runs of PVC insulated cable(FRLS) 6 sqmm copper conductor multi stranded and 2 runs of 6 sqmm copper conductor insulated cable (FRLS) using as earth wire and drawn in to and including PVC Casing and caping incl all accessories as bend,tee,junction boxes elbows etc complete all as specified and directed.
Note : 6 runs of 6 Sqmm cable and PVC casing and caping shall be measured one unit length.
30
-
-
Taking down ceiling fan of any type and size, cable ends, dimantling blades and removing fan and balde to store yard and Hanging/ fixing only repaired/ reconditioned Fan of any type and size and connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed.
90
-
-
Collection of unserviceable ceiling fan 1200mm/1400mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceable winding from fan state & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed.
Note : Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps shall be measured & paid separatetly.
90
-
-
All as per item No 44 here-in-before but exhaust fan 300 mm sweep
30
-
-
All as per item No 44 here-in-before but exhaust fan 450 mm sweep
5
-
-
All as per item No 44 here-in-before but Wall fan 450 mm sweep
10
-
-
All as per item No 44 here-in-before but pedestal fan 400 mm sweep
10
-
-
Material and labour for Scraping down old paint of ceiling fan of any size sweep complete body & blade including down rod filling the cavities with filler and making smooth surface by applying two coats of synthetic enamel paint over a coat of primer after prepation with sand paper by means spray gun/brush with all as specified and as directed.
90
-
-
M&L for lathe work for proper filling/fixing of bearing/bushes in the top cover of the fan by filling a layer of matter after blazing & bottom cover of fan complete all as specified and directed.
50
-
-
Supply only 12V microcontroller card for BLDC ceiling fan of 1200mm/1400mm sweepcomplete all as specified and as directed.
25
-
-
Supply only BLDC 18 pol stamping for BLDC ceiling fan of 1200mm/1400mm sweepcomplete all as specified and as directed.
15
-
-
Supply only shaft length 152mm for BLDC ceiling fan of 1200mm/1400mm sweepcomplete all as specified and as directed.
15
-
-
Supply only plastic ring for BLDC ceiling fan of 1200mm/1400mm sweepcomplete all as specified and as directed.
25
-
-
Supply only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL
50
-
-
Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample
40
-
-
Supply only Gun metal bush for ceiling fan complete all as specified and directed.
1
-
-
Supply only Shackle type rubber reel,'U' clamps, bolts,split pin & washer complete all as specified and directed.
30
-
-
Supply only Canopy top/bottom suitable for 20 mm dia rod complete all as specified and directed.
20
-
-
Supply only Down rod 300 mm long of size 20 mm dia ISI marked complete all as specified and directed.
20
-
-
Supply only Fan blades suitable for 1200 mm sweep fan make & type as directed by Engr-in-Charge.
30
-
-
Supply only 1.2mm thick mild steel top/bottom cover for ceiling fan any size and make as directed by Engr-in-Charge.
25
-
-
Supply and fixing Exhaust fan blade of 300 mm sweep complete as per sample of the following sizes as directed by Engr-in-Charge.
15
-
-
All as per item No 63 here-in-before but for 450 mm sweep
2
-
-
Supply and fixing Wall mounting fan blade 450 mm sweep and make suitable for fixing and as per sample of existing fan complete all as specified and directed .
5
-
-
Supply and fixing pedestal fan blade 400 mm sweep and make suitable for fixing and as per sample of existing fan complete all as specified and directed .
5
-
-
Supply and fixing Exhaust fan clamps including frame and louvers with ruber bush, etc suitbale for 300 mm sweep complete as per sample as directed by Engr-in-Charge.
10
-
-
All as per item No 67 here-in-before but for 450 mm sweep.
2
-
-
Supply and fixing Oscillating mechanism suitable for wall mounting fan any make and type all as directed by Engineer-in-charge.
10
-
-
Supply and fixing in replacement of Exhaust fan Motor of 300 mm sweep complete as per sample of the following sizes as directed by Engr-in-Charge.
20
-
-
All as per item No 70 here-in-before but for Exhaust fan 450 mm sweep
2
-
-
All as per item No 70 here-in-before but for wall fan 450 mm sweep
10
-
-
All as per item No 70 here-in-before but for pedestal fan 400 mm sweep
5
-
-
Taking down geyser carefully of any make and capacity 25/50ltrs, dismantling the geyser for inspection, cleaning of tank, repalcement of defective part such as heating element, thermostat switch, spacer ring, safety plug, glass wool, neon lamp, head assembly, rubber gasket, top and bottom cover, inspection plate, copper cable 3 core, 3 pin Top plug, element holding clamp, welding of studs for head assembly, defective inner and outer shell reassembling the geysers with one coat of milky white enameled, spray paint of approved quality after cleaning of all dust rust etc and writing of MES No on the geyser using black paint, Reinstallation of geysers to its original postion complete all as specified. Note : Supply only Spare parts such as heating element thermostat switch, spacer ring, heon lamp, head assembly, glass wool, safety plug rubber, gasket, copper cable, top & bottom cover, inspection plate, CP & PVC connection, Plug Top, Outer & Inner shell element holding clamps etc shall be measured & paid for seperately in respective items here in after.
50
-
-
Supply and fixing heating element any type (i.e; Cup,thread or triangular) 1.5 KW, 220/230 volts ISI marked.
12
-
-
Supply and fixing Thermostat ISI marked complete all as specified and directed by Engr-in-Charge.
12
-
-
Supply and fixing Head Assy "Brass" 8 to 9 holes suitable for 25 ltrs capacity all as directed by Engineer-in-charge.
10
-
-
Supply and fixing Safety plug "brass" ISI marked suitable for 25/50 ltrs geyers
10
-
-
Supply and fixing Hot and cold water connection made of brass pipe, chrumium plated upto 18" length complete with rubber washer & brass nuts, ISI marked all as directed by Engineer-in-charge.
20
-
-
Supply and fixing geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity all as specified and directed by Engr-in-Charge.
10
-
-
Supply and fixing bottom cover plate in two halves with self toppiry suitable and as per sample complete all as specified & directed by Engr-in-Charge. Make :Bajaj, Peeco, Recold/DITZ
14
-
-
Supply and fixing phase indicator red colour circular/rectangular shape as suitable and as per sample complete all as specified and directed by Engr-in-Charge.
15
-
-
Supply and fixing non return brass valve of 15mm bore, ISI marked as specified and directed by Engr-in-Charge.
10
-
-
Supply and fixing pressure release brass valve of 15mm bore ISI marked all as specified and directed by Engr-in-Charge.
15
-
-
Supply and fixing PVC connection wire woven with nickel plated brass adopter, both side threaded 45cm long the to suitable size of geysers complete all as specified and directed by Engr-in-Charge
20
-
-
Supply and fixing Plug top 3 Pin 16 Amps 230 volts all as specified and directed by Engr-in-Charge.
20
-
-
M&L for servicing incl cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for split type AC of any make/ capacity after taking down the whole unit and refixing at the existing location or any other new location after servicing all as specified and directed by Engr- in- Charge . (Note: S&F spare parts will be measured and paid separately under relevant item.)
90
-
-
Taking down of Split type Air Conditioner of any capacity 1.5/2 TR from existing location incl removal of outdoor unit by opening all electrical connection and suction & discharge line connection carefully & removing materials to store for keeping in safe custody for reuse at site. Filling the opening of old location with cement mortar, applying white wash on wall with matching with existing colour of the site. Refixing, installation of Split type Air Conditioner of any capacity 1.5/2 TR by filling of refrigerant, fixing of new bracket for installation of outdoor unit, fixing of suction and discharge copper tubes with replacement of insulation of suction & discharge line and making holes for passing of suction & discharge line through brick wall incl well finish with cement mortar, applying white wash, colour wash, distemper etc on wall to match with existing colour of the adjacent surface at new location, etc. complete all as specified and directed by Engineer-in Charge.
10
-
-
M&L for Shifting of water cooler electric driven single phase having any make and capacity from MES yard/existing location by taking it after disconnection of electric and water line and refixing the same in any other new location incl water and electric reconnection complete all as specified and as directed.
2
-
-
Supply and fix in replacement of the swing blade assembly comprises of swing blades and connecting rods used for driving the swing blades to swing synchronously for Split type air conditioner of capacity 2/1.5 TR complete all as specified and directed
10
-
-
Supply and fix in replacement of AC blower fan motor for AC suitable for 1.5/2 TR split type AC suitable operate on 230 Volt AC supply at 50 HZ.
5
-
-
Supply and fix in replacement of AC indoor cooling condenser for Split type air conditioner of capacity 1.5/2 TR complete all as specified and directed. Make: LG/VOLTAS/ AIRCON/ VIDEOCON / SIDWAL or equivalent as approved by GE
5
-
-
Supply and Fix in repair Air filters set of two of 1.5/2.0 Ton split type AC complete all as specified and as directed. (Make:FIL/ UTILITY/ SPENCER/ VOLTAS/ AIRCON/ VIDEOCON / SIDWAL).
10
-
-
Supply and fix in replacement of indoor AC unit back plate for Split type air conditioner of capacity 1.5/2 TR complete all as specified and directed
10
-
-
Supply and fix in replacement of indoor AC blower fan bush for Split type air conditioner capacity 1.5/2 TR complete all as specified and directed.
5
-
-
Supply and fix in replacement of indoor AC swing blades motor for Split type air conditioner of capacity 1.5/2 TR complete all as specified and directed
10
-
-
Supply and fix in replacement of Printed Circuit Board suitable for 2TR Capacity Split Unit Air Conditioners including remote, etc. Make LG/equivalent as approved by GE
6
-
-
Supply and fix in replacement of Printed Circuit Board suitable for 1.5TR Capacity Split Unit Air Conditioners including remote, etc. all as specified and as directed. Make LG/equivalent as approved by GE.
6
-
-
M&L for Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer.
2
-
-
Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer. Make : LG/ Voltas/ Samsung complete all as specified and directed.
2
-
-
M&L for Disconnecting, dismantling and taking out existing burnt out compressor from water cooler of capacity 40 to 80 Ltr per Hour singlephase 230 volts and supply and fixing compressor unit of water cooler of capacity 40 to 60 ltrs as speciifed by Engr-in-charge.
Make : LG/ Voltas/ Samsung complete all as specified and directed.
2
-
-
Supply and fix in replacement of Capacitor 45 MFD complete all as specified and as directed.
Make : Cat Part No QHLIDC545006 in Havells or equivalent in L&T/Surya
20
-
-
supply and fix in replacement of relay contactor 6 pin 220-240V AC completed all as specified and directed
5
-
-
Supply and fix in replacement of Thermostat switch for water cooler/Window AC complete all as specified and as directed.
10
-
-
Supply and fix in replacement of Drier stainer filter suitable for AC/Water cooler/Refrigertor complete all as specified and as directed.
10
-
-
Supply and fix of insulation Nytrile foam insulation suitable for 3/4 inch copper tube as per site requirement of approved make all as specified and directed .
40
-
-
Supply and fix of insulation Nytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved make all as specified and directed .
40
-
-
Supply and fix in replacement of Copper tube 3/4 inch size as per site requirement of approved make all as specified and as directed.
40
-
-
Supply and fix in replacement of Copper tube 1/4 inch size of approved make all as specified and directed .
40
-
-
Supply and fix in replacement of Evaporator unit (indoor unit ) complete suitable for 1.5TR Capacity Split type Air Conditioners all as specified and as directed. Make : LG/ Voltas/Goderj
1
-
-
Supply and fix in replacement of Condensing (Out door) unit complete including compressor, etc. Suitable for 2TR Capcity Air conditioners all as specified and as directed. Make : LG/Voltas/Goderj/Total line/Techmesh
2
-
-
Supply and fix in replacement of Bracket stand suitable for 2TR/1.5TR Capacity Split type AC including Fastners, etc. all as specified and as directed.
5
-
-
Supply and charging R-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling appliances (charging cost incl in this item) all as specified and as directed.
42
-
-
Supply and charging R-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces incl. (charging cost incl in this item) all as specified and as directed.
10
-
-
Schedule of Credit (Minus) Rs.28647.00 NOTE: Bidder shall insert credit amount of Rs. 28647.00 as rate in Green field under Col-13.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements