Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 4,46,800Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676446_1Tender No
890797ATender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Total amount of Sch 'A' Part-IV (INTERNAL ELECTRIC SUPPLY)
1
-
24934.2
Total amount of Sch 'A' Part-V (EXTERNAL WATER SUPPLY)
1
-
1674817.58
Total amount of Sch 'A' Part-VI (SEWAGE DISPOSAL)
1
-
73957.05
Total amount of Sch 'A' Part-VII (AREA DRAINAGE)
1
-
204347.68
Total amount of Sch 'A' Part-VIII (FENCING/GATE)
1
-
1632622.29
Total amount of Sch 'A' Part- IX (ROAD/ PATH/CULVERT/ HARD STANDING)
1
-
3194478.93
Sch 'A' Part- X (MISCELLANEOUS ITEMS) (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
-
-
-
INTERNAL ELECTRIFICATION:
-
-
-
Point wiring with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked in and including PVC concealed conduit and conduit accessories, concealed in wall/roof/floor etc, ISI marked including 2 mm thick terminal boxes and 3 mm thick plastic laminated sheet cover of suitable colour to match the colour of adjacent surface for mounting of switches , sockets etc and PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S. cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- (NOTE :- Switch and socket to be measured and paid for separately) :-
-
-
-
(a) One light/Ceiling Fan/ Exhaust fan point controlled by one 5/6 amps one way switch.
78
-
-
(b) One Socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin.
21
-
-
Point wiring with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked in and including PVC concealed conduit and conduit accessories, concealed in wall/roof/floor etc, ISI marked including 2 mm thick terminal boxes and 3 mm thick plastic laminated sheet cover for mounting of switches , sockets etc and PVC insulated multi-stranded copper conductor 2.5 Sqmm nominal cross sectional area single core F.R.L.S. cable as earth continuity conductor to common earth and connecting to earth dolly complete for one socket point 15 Amp
21
-
-
Ceiling fan 1200mm sweep copper wound having minimum 5 star rating , including step regulator, down rod suitable height and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from connector to fan, all as specified and as directed.
14
-
-
Exhaust fan 300 mm sweep Heavy duty 1400 rpm metal body,230 Volts AC 50 Hz with copper wound having minimum 5 star rating and including complete all as specified and directed.
4
-
-
LED tube light 1x20 Watt 6000K complete with tube and frame extruded al heat sink with electric driver etc Havells Cat Part No LHEWEBP51N1W020 or equivalent make given in the list of manufactures all as specified and as directed.
42
-
-
Decorative wall light fitting made of polycarbonate suitable for 1X10 Watt suitable for B-22 Base including 1X10 Watt LED Lamp (Make : Havells Cat Part No LHDL02160099 or equivalent make given in the list of manufactures , all as specified and as directed.
4
-
-
Street light fitting pressure die cast aluminium housing heat resistance toughtned glass having IP 66 protection of 25 Watt complete including fixing with GI Bracket made of 32 mm dia medium grade GI Pipe including fixing clamps etc complete. (Make Havells 25W LED IP66 security light Model No.LHETAXU7PA6J025 or equivalent make given in the list of manufactures , all as specified and as directed.
14
-
-
MCB DB SPN 8 way double door 240 Volts with200 Amp bus bar, all asspecified and as directed.
7
-
-
MCB SPN 6 to 32 Amps C curve, all as specified and as directed.
7
-
-
MCB SP 6 to 32 Amps C curve, all as specified and as directed.
28
-
-
Submain wiring with 4 sq mm two single core(for phases and neutral) using multistranded copper conductor PVC (FRLS) insulated unsheathed with and incl 4 sq mm insulated unsheathed PVC insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC concealed conduit ISI marked with accessories (Note: 03 runs of 4 sqmm and one run of PVC concealed conduit shall be measured as one run only
55
-
-
INTERNAL WATER SUPPLY:
-
-
-
Angular stop cock, chromium plated, cast copper alloy, screwed down, screwed for iron pipe 15 mm dia bore. Make Jaquar Code No CON-059KNor equivalent, all as specified and directed.
12
-
-
Bib tap, cast copper alloy, chromium plated, fancy type of size 15mm, long body, with CP cup., all as specified and as directed
8
-
-
Concealed stop cock, chromium plated fancy type with long shank and cup 15 mm dia. Make Jaquar Code No CON-059KNor equivalent all as specified and directed.
4
-
-
Health Faucet with 1 Mtr flexible tube in chrome finish16 mm dia (outer), low density ploythene, suitable for cold water application complete with union and teflone washers and holder to suit 15 mm angle cocks (Make : Jaguar cat part No ALD-IVY-585 or equivalent)., all as specified and directed.
4
-
-
Shower rose 65mm with Shower arm 15 mm size 195 mm long body bend of 45 degree with wall flange SS as directed by Engr in charge, all as specified and directed.
4
-
-
Low density ploythene pipe 16 mm dia (outer), metallic baided, 450 mm long suitable for cold water application complete with brass union on both sides, all as specified and directed.
8
-
-
Pillar taps 15 mm Dia , long neck chromium plated cat pt no CQT -23021 of make Jaquar , all as specified and directed.
4
-
-
Rotational moulded polyethylene water storage tank 250 Ltr capacity hoisted and fixed in position all as specified in SSR part-I, all as specified and directed.
4
-
-
EXTERNAL ELECTRIC SUPPLY:
-
-
-
Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 11000Volts grade of size 3.5 Core 35 Sqmm laid in duct/floor complete all as specified and directed
200
-
-
All as per item No 35 here-in-before but 4 core 16 sqmm
100
-
-
Manufactured sand cushioning for under ground cables complete all as specified and as directed by the Engr-in-Charge.(Note : punned thicknes shall be measured & paid)
19
-
-
Un-reinforced precast concrete cable cover of class LV, Type flat of size 250mmx150mmx40mm laid in trenches for protection of 1100 volt armoudred cable all as specified and directed by the Engr- in- Charge.
1591
-
-
Double compression copper stain less steel gland for fixing armoured cable in panel of 3.5 Core 35 Sqmm
6
-
-
Double compression copper stain less steel gland for fixing armoured cable in panel of 4 Core 16 Sqmm
2
-
-
MCCB 100 Amp 4 ploe breaking capacity 36 KA at 415V with sheet metal enclosure for indoor type.
2
-
-
Out door type feeder pillar box factory made out of 3 mm thick CRCA sheet and 40 x 40 x 6 mm angle iron frame front and back opening complete with locking arrangement, duly painted with two coats of powder coated paint over a coat of anticorrosive primer, grouted on PCC pillar, complete with comprising of the following incoming and out going arrangement :-
(a) MCCB 4 Pole 40 Amps 18 kA - 01 No
2
-
-
Cutting into existing bituminous carpet road/PCC hard standing upto a depth of 30cm for laying of UG cable/GI pipe and making good the disturbed surfaces to match with the existing surface complete all as specified and directed.
20
-
-
EXTERNAL WATER SUPPLY:
-
-
-
Centrifugally cast (spun) ductile iron pipes of 100 mm dia suitable for pressurized water delivery with spigot & socket end, class 'K-9' conforming to IS:8329/2000 (latest version) - blast furnace slag cement with portland cement properties suitable for (push on) rubber gasket jointing with inside cement mortar lining and black bitumen external coating, duly ISI marked in any length including testing and commissioning all as specified and directed.
Note for serial item Nos 43to 46:-The rate quoted shall deemed to be included for material and labour for push on type rubber ring joints required for jointing the pipe and fittings with respective sizes and also for the flanged joints wherever required for pipes,fittings and valves.
150.5
-
-
All as per item No 45 above but of size 150 mm dia complete all as specified and as directed.
29.1
-
-
All as per item No 45 above but of size 200 mm dia complete all as specified and as directed.
7.5
-
-
All as per item No 45 above but of size 250 mm dia complete all as specified and as directed.
148
-
-
Supplying and laying Ductile iron pipes 300mm bore including jointing in standard length with flanged ends ,class" K-9"conforming to IS 8329-2000(latest version) in any length laid in trenches /floor all as specified and as directed.
Note:-The rate quoted shall deemed to be included for material and labour for jointing with ribber packing, nuts, bolts and washers required for jointing the pipe and fittings with respective sizes and all for the flanged joints wherever required for pipes ,fittings and valves.
75
-
-
Constructing of brick masonary valve chamber of internal dimensions 1mtr x1mtr x1.2 mtrs ( bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space) , bottom floor of the pit be constructed in PCC (1:3:6) 15 cms thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 MM thick. The sluice valve and other fittings should be housed in center of the pit. the vertices of the pit should in right angle and champhered .The top cover of the pit will be made out of MS sheet min 5mm thick witth angle iron frame made out of MS angle 50mm x50 mmx 6 mm with galvanised steel hindges two nos ,and locking arrangements duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide.
40
-
-
Ductile iron socketed fittings supplied as per IS: 9523/2000 of class K-12, PN-10 for pressurized water delivery with inside Cement Mortar lining and outside zinc followed by black bitumen coating for size 100 mm dia to 250 mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch,cross collars, caps and plug set including rubber ring push on joints complete as specified and directed.
2772
-
-
All as per item No 51 above heren in above but DI flanged fittings of size 100 mm dia to 250mm dia including material and labour for flanged joints all as specified and as directed.
263
-
-
Centrifugal pumping set electric driven 3 phase, 415 Volts,50 HZ 20 LPS, 45 Mtr Head of minimum capacity 20HP complete mounted on common base frame with necessary cable from starter panel to motor incl provision for priming system complte with fixing in PCC foundation with neccessary fittings ,nut bolt and washers etc complete all as specifiied and as directed.
2
-
-
All as per item No 53 above but 36 LPS, 45 mtr head of minimum capacity 40 HP complete all as specied and as directed
2
-
-
All as per item No 53 above but 12.5 LPS , 45 mtr head of minimum capacity 10HP complete all as specified and as directed
2
-
-
Cast iron Air release valve with two air outlets 100 mm bore and fixing up in cast iron water supply mains all as specified and as directed
5
-
-
All as per item No. 56 here in before but of size 80mm bore, all as specified and as directed.
8
-
-
LT Panel Board indoor type fabricated by 2mm thick CRCA sheet, factory fabricated,from CPRI tested/approved fabrication dust and vermin proof, duly powder coated complete with aluminum bus bar 200 Amps capacity - 4 Nos, colour busbar insulators etc and connections from bus bar to all incoming and outgoing MCCBs comprising the and following accessories :-
(a) MCCB TP 63 Amps - 01 No
(b) MCB TP 32 Amos - 03 Nos
(c) Volt meter 0.500 Volts with selector switch - 01 No
(d) Amps Meter with selector switch for pump set - 02 Nos
(e) Fully automatic Star Delta Starter 10 HP Motor - 3 Nos
(f) Single phase preventor
(g) Phase indicating lamps R,Y, B - 01 set
(h) Cement contrete foundations, filling and mass concree type C2 1:3:6 (40mm graded aggregate)
1
-
-
LT Panel Board indoor type fabricated by 2mm thick CRCA sheet,factory fabricated,from CPRI tested/approved fabrication dust and vermin proof, duly powder coated complete with aluminum bus bar 200 Amps capacity - 4 Nos, colour busbar insulators etc and connections from bus bar to all incoming and outgoing MCCBs and following accessories - (a) MCCB TPN 125 Amps, KA 18 - 01 No
(b) MCB TP 63 Amps - 03 Nos
(c) Volt meter 0.500 Volts with selector switch - 01 No
(d) Amps Meter with selector switch for pump set - 02 Nos
(e) Fully automatic Star Delta Starter 30 HP Motor - 3 Nos
(f) Single phase preventor
(g) Phase indicating lamps R,Y, B - 01 set
(h) Cement conrete foundations, filling and mass concrete type C2 1:3:6 (40mm graded aggregate)
1
-
-
LT Panel Board indoor type fabricated by 2mm thick CRCA sheet,factory fabricated,from CPRI tested/approved fabrication dust and vermin proof, duly powder coated complete with aluminum bus bar 200 Amps capacity - 4 Nos, colour busbar insulators etc and connections from bus bar to all incoming and outgoing MCCBs and following accessories :- (a) MCCB TP 100 Amps 18 KA- 01 No
(b) MCB TP 63 Amps - 03 Nos
(c) Volt meter 0.500 Volts with selector switch - 01 No
(d) Amps Meter with selector switch for pump set - 02 Nos
(e) Fully automatic Star Delta Starter 20-25 HP capacity - 3 Nos
(f) Single phase preventor
(g) Phase indicating lamps R,Y, B - 01 set
(h) Cement contree folndations, filling and mass concrete type C2 1:3:6 (40mm graded aggregate)
1
-
-
LT Panel Board indoor type fabricated by 2mm thick CRCA sheet,factory fabricated,from CPRI tested/approved fabrication dust and vermin proof, duly powder coated complete with aluminum bus bar 200 Amps capacity - 4 Nos, colour busbar insulators etc and connections from bus bar to all incoming and outgoing MCCBs and following accessories - (a) MCCB TPN 160Amps, KA 18 - 01 No
(b) MCB TP 100mps - 03 Nos
(c) Volt meter 0.500 Volts with selector switch - 01 No
(d) Amps Meter with selector switch for pump set - 02 Nos
(e) Fully automatic Star Delta Starter 40 HP Motor - 3 Nos
(f) Single phase preventor
(g) Phase indicating lamps R,Y, B - 01 set
(h) Cement contrete foundations, filling and mass concrete type C2 1:3:6 (40mm graded aggregate) (h) Cement contree folndations, filling and mass concrete type C2 1:3:6 (40mm graded aggregate)
1
-
-
LT Panel Board indoor type fabricated by 2mm thick CRCA sheet,factory fabricated,from CPRI tested/approved fabricationdust and vermin proof, duly powder coated complete with aluminum bus bar 200 Amps capacity - 4 Nos, colour busbar insulators etc and connections from bus bar to all incoming and outgoing MCCBs and following accessories - (a) MCCB TPN 200 Amps, KA 18 - 01 No
(b) MCB TP 100 Amps - 03 Nos
(c) Volt meter 0-500 Volts with selector switch - 01 No
(d) Amps Meter with selector switch for pump set - 02 Nos
(e) Fully automatic Star Delta Starter 55 HP Motor - 3 Nos
(f) Siungle Phase Preventer phase indication lamps R,Y, B - 01 set
(g) Cement concrete foundations, filling and mass concrete type C2 1:3:6 (40mm graded aggregate)type C2 1:3:6 (40mm graded aggregate)
1
-
-
Three layer Rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top )white colour inside hoisted & fixed in position of capacity 500 liters complete all as specified and as directed.
7
-
-
Bore Packing : For Inlet & Out let pipes in any radius. The procedures are as under :-
Preparing the inside surface core and PVC/MS pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Providing neccessary formwork for packing the bore using suitable arrangement (depending upon site conditions). Applying a coat of styrene-butadiene based polymer coating using Nitobond SBR to enhance adhesion between the packing material and other surfaces. Packing the gap using non shrink cement polymer based grout using Conbextra GP2 upto the surface of the bore whilst the Nitobobd SBR is in tacky Tensile strength at 28 day--3.5N/mm2,Flexural strength at 7 day as per BS4551 ---9N/mm2,Bond strength at 7 day ---7N/mm2 and all as specified and directed by Engr-In-Charge. Note:- Make of material FOSROC or equilent and work will be executed by manufacturer's authorized applicator only. and warranty for the work will be given for 5 years from the authrized manufactures from the date of completion of work.
7
-
-
Upgradation of the exisiting SCADA software to incorporate managment and control of New Pump House including develop and add the addiotinal features as described below the Linking of the Automated Pump houses to Main Pump House by altering the exsiting SCADA software including a)Development of libraries and screens for display of the schematic of the remote Pump houses b) Creation of additional soft keys for remote / manual operation of the pumps and motorised valves in the above mentioned pump houses. c) Modification of the Main SCADA screen to create a link to easily navigate to the newly dveleoped PH schemtic screen etc. as required. The scope of work also includes upgradation of the exsiting SCADA software by developing and incorporating the following utilities; a) otnet Based Reporting Software with unlimited no of user configurable reports along with selection of time period, parameters, events, alarms complete with user defined Logo user name, date and time, page no., header and footer. The Report should be in Microsoft Excel format. b) Email and SMS Utility Software user configurable in terms of Phone Book Creation, Database Selection, Message content, enable/ disable time with triggering by Digital and Analog Values , Formulae and Comaparison results. The scope of work also includes establishing communication between the static IP based communication system at the Main Pump House and by altering the exsiting SCADA software.
1
-
-
Programmable Logic Controller based Pump Automation and Protection Panel at (06 Nos motorized valves(provision of additional +02 nos valves) ,04 Nos pumps,04 Nos Pressure Transmitter) . The panel shall be of min size 1000mm x 600mm x 200mm. fabricated from 1.6 mm thick CRCA sheet and properly powder coated to operate the water supply system and act as a user control and audiovisual indication system. It shall be wall mounted / floor mounted The PLC and Panel shall be as specified and the panel shall be provided with the following features:-
(a) Water Level Sensing & Display
(b) Pump On/Off (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Preventor (h) Manual Mode Operation
The panel will comprise of :-
(a) PLC comprising of Main Controller, MMI with display, expansion adaptors, input// output module (b) Selector switch
(c) Indicator lamps
d) Push buttons
e) Relays
f) Audio signal generator
(g) Intenal wiring
1
-
-
Item No.66 (Contd.....) h) Connectors
i) Relay modules
j) Internal wiring
k) Connectors
l) Relay modules
g) Internal wiring
m) Connectors
n) Relay modules
o) Transformers
ake: - RECKTRONIC DEVICES & SYSTEMS (KB main ph)
-
-
-
Programmable Logic Controller based Pump Automation and Protection Panel at (04 Nos motorized valves(provision of additional +04 nos valves) ,02 Nos pumps,02 Nos Pressure Transmitter) . The panel shall be of min size 1000mm x 600mm x 200mm. fabricated from 1.6 mm thick CRCA sheet and properly powder coated to operate the water supply system and act as a user control and audiovisual indication system. It shall be wall mounted / floor mounted The PLC and Panel shall be as specified and the panel shall be provided with the following features:-
(a) Water Level Sensing & Display
(b) Pump On/Off (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Preventor (h) Manual Mode Operation
2
-
-
Item No.68 (Contd.....) The panel will comprise of :-
(a) PLC comprising of Main Controller, MMI with display, expansion adaptors, input// output module (b) Selector switch
(c) Indicator lamps
d) Push buttons
e) Relays
f) Audio signal generator
g) Internal wiring
h) Connectors
-
-
-
Item No.68 (Contd.....) (i) Relay modules
(j) Transformers
(k) PLC..PLC Interface
(l) PLC..modem interface
(m) MCBs (n) Wireless modem, Omni directional antenna, power supply, patch cord, PLC to modem communication cord etc. as required for On Line communication with the centralized SCADA system. Make: - RECKTRONIC DEVICES & SYSTEMS (at 29 CPO & 32 CPO )
-
-
-
Programmable Logic Controller based Pump Automation and Protection Panel at (06 Nos motorized valves(provision of additional +02 nos valves) ,02 Nos pumps,02 Nos Pressure Transmitter) . The panel shall be of min size 1000mm x 600mm x 200mm. fabricated from 1.6 mm thick CRCA sheet and properly powder coated to operate the water supply system and act as a user control and audiovisual indication system. It shall be wall mounted / floor mounted The PLC and Panel shall be as specified and the panel shall be provided with the following features:-
(a) Water Level Sensing & Display
(b) Pump On/Off (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Preventor (h) Manual Mode Operation
The panel will comprise of :-
(a) PLC comprising of Main Controller, MMI with display, expansion adaptors, input// output module (b) Selector switch
(c) Indicator lamps
d) Push buttons
1
-
-
Item No.71 (Contd.....) e) Relays
f) Audio signal generator
g) Internal wiring
h) Connectors
i) Relay modules
j) Transformers
k) PLC..PLC Interface
l) PLC..modem interface
m) MCBs n) Wireless modem, Omni directional antenna, power supply, patch cord, PLC to modem communication cord etc. as required for On Line communication with the centralized SCADA system. Make: - RECKTRONIC DEVICES & SYSTEMS (at DSC Pump house )
-
-
-
Actuator with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure along with wafer type butterfly valve with the following specifications. Valve size: 50 mm dia.
Designed line pressure: 6 kg/sq cm.
Operating Angle: 90 degrees
Disc Material: CI with nylon coating
Limit Switches : 02 Nos.For open and close Mounting : Internal-Splash Proof Make: RITETORK /EMCORK/HASEL HOPEMER
9
-
-
Actuator with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure along with wafer type butterfly valve with the following specifications. Valve size: 100 mm dia.
Designed line pressure: 10 kg/sq cm.
Operating Angle: 90 degrees
Disc Material: CI with nylon coating
Limit Switches : 02 Nos.For open and close Mounting : indirect
Make: RITETORK /EMTORK/HASEL HOFENER
3
-
-
Actuator with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure along with wafer type butterfly valve with the following specifications. Valve size: 200 mm dia.
Designed line pressure: 10 kg/sq cm.
Operating Angle: 90 degrees
Disc Material: CI with nylon coating
Limit Switches : 02 Nos.For open and close Mounting : direct
Make: RITETORK /EMCORK/HASEL HOPEMER
4
-
-
Actuator with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure along with wafer type butterfly valve with the following specifications. Valve size: 100 mm dia.
Designed line pressure: 10kg/sq cm.
Operating Angle: 90 degrees
Disc Material: CI with nylon coating
Limit Switches : 02 Nos.For open and close Mounting : direct
Make: RITETORK /EMCORK/HASEL HOPEMER
3
-
-
Solenoid valve suitable for 25mm GI pipe for priming of pump including suitable bypass with necessary GI fittings with following specifications: Size: 25 mm
Material : SS/ Forged Brass/ Cast Bronze
Pressure rating: 6 kg / sq. cm.
Make: AVCON /EMTORK/HASEL HOFENER
9
-
-
Solenoid valve suitable for 10mm GI pipe for priming of pump including bypass arrangement using 10 mm. gate / ball valve with necessary GI fittings with following specifications: Size: 10 mm
Material : SS/ Forged Brass/ Cast Bronze
Type: Pilot operated, diaphragm type / direct acting type.
Pressure rating: 6 kg / sq. cm.
Normally closed
Make: AVCON /EMTORK/HASEL HOFENER
6
-
-
Pressure transmitter with following specification:
Power supply: 10-36 V DC
Process connection: G ½ “
Enclosure: whether proof IP 65
Process temperature: -30 to 120 celcius
Accuracy: 0.25 %
Make: DANFOSS/ INDFOSS /AVCON /EMTORK/HASEL HOFENER
10
-
-
Sensors with following specifications: rust proof, maintenance free,magnetic float switch, all as specified and as directed.
10
-
-
2 x 1.5 sq.mm. PVC insulated and PVC sheathed armoured coppercable with suitable size of saddles etc complete etc as required fixed on wall drawn through pipe, as specified and as directed. (Two layers will be measured as one length).
400
-
-
25 mm dia class A, G.I pipe as required laid in ground fixed in wall, as specified and as directed.
2
-
-
Interconnection between sintex over head tanks, as specified and as directed.
15
-
-
Indoor type, floor mounted, L.T Panel board suitable for 415 Volts, 3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, indoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 2.00mm thick and 50X50X6mm thick MS angle iron pedestal work. The panel shall be front and back openable and having inner & outer shells. The inner shell duly compartmented for each control gear, chemically treated against corrosion by seven tank process and powder coated with Siemens gray shade RAL 7032, front and rear opening type with locking arrangements and comprising of the following:- (For 32 CPO Pump House)
INCOMING (a) MCCB 100 Amps 25 KA breaking capacity, adjustable Thermal and Magnetic type. - 01 Nos (b) Bus Bar 4 pole 400 Amps - 1 Set (c) Digital AC LED multifunction meter , 3 phase - 01 each (d) Indicating Lamps LED type 1 Set (e) Sliding fuse unit including apropriate capacity HRC fuse 03 Nos - 01 Set OUTGOING (a) MCCB 63 Amps 3 P 25 KA breaking capacity, ajustable Thermal and Magnetic type - 03Nos (01 Spare) (b) MCCB 40 Amps 3 P,18 KA breaking capacity , fixed type - 02Nos (c) MCB SPN 32 Amps 'C'series - 01Nos
1
-
-
Indoor type, floor mounted, L.T Panel board suitable for 415 Volts, 3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, indoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 2.00mm thick and 50X50X6mm thick MS angle iron pedestal work. The panel shall be front and back openable and having inner & outer shells. The inner shell duly compartmented for each control gear, chemically treated against corrosion by seven tank process and powder coated with Siemens gray shade RAL 7032, front and rear opening type with locking arrangements and comprising of the following:- (For DSC Pump House)
INCOMING (a) MCCB 100 Amps 25 KA breaking capacity, adjustable Thermal and Magnetic type - 01 Nos (b) Bus Bar 4 pole 400 Amps - 1 Set (c) Digital AC LED multifunction meter , 3 phase - 01 each (d) Indicating Lamps LED type 1 Set (d) Indicating Lamps LED type 1 Set (e) Sliding fuse unit including apropriate capacity HRC fuse 03 Nos - 01 Set OUTGOING (a) (a) MCCB 40 Amps 3 P,18 KA breaking capacity , fixed type - 05Nos (01 Spare) (b) MCB SPN 32 Amps, 'C'series - 01Nos
1
-
-
Earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized earth strip 32X6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed by Engr-in-Charge.
3
-
-
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in continuity pipe or any other inclicated suitable for loop earthing etc. using 32x6 mm galvanised iron strip.
106
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%