Military Engineer Services Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Sep 2024
Closing Date3 Oct 2024
Tender Amount₹ 49,90,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 2 here-in-before but for 5 pin 5 Amps socket outlet point on same board.

70

-

-

... More
All as per item No 2 here-in-before but using 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable and 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable earth wire with terminal box of suitable size complete all as specified.

50

-

-

... More
All as per item No 2 above but with 4 Sqmm copper conductor including 4.0 Sqmm copper cable on earth wire for sheet metal enclosure

30

-

-

... More
S&F switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.

200

-

-

... More
S&F switch piano flush type single pole one way 15 Amp complete all as specified and as directed .

50

-

-

... More
S&F socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed.

120

-

-

... More
S&F socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed.

80

-

-

... More
S&F Ceiling rose surface Bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed.

200

-

-

... More
S&F bell push flush type 5 Amps single pole complete all as specified and as directed.

50

-

-

... More
S&F Electric bell, AC 230 Volt single pole complete all as specified and as directed.

80

-

-

... More
S&F in repair, switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.

600

-

-

... More
S&F in repair, switch piano flush type single pole one way 15 Amp complete all as specified and as directed.

200

-

-

... More
S&F in repair, socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed.

300

-

-

... More
S&F in repair, socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified.

200

-

-

... More
S&F in repair, switch socket combination 5 Amps, 5 pin 2 in 1 , complete all as specified.

300

-

-

... More
S&F in repair, switch socket combination multipurpose 5 & 15 Amps, 5 pin, 2 in 1 complete all as specified.

300

-

-

... More
S&F in repair fan regulator electronic step type 100 W, 250 Volts complete all as specified.

400

-

-

... More
S&F in repair, capacitor 2.5 MFD for ceiling fans complete all as specified.

500

-

-

... More
S&F in repair, lamp holder ,PVC /poly carbonate type with back plate suitable for batten fittings , all as specified.

100

-

-

... More
S&F Ceiling rose surface Bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed.

200

-

-

... More
S&F in repair, Switch socket combination 2 in 1, 3 pin, 5A/16A, 5 in 1 flush type with fuse & neon indicator complete all as specified and as directed.

100

-

-

... More
M&L in repairs sub main wiring with 4 runs of 6 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC Casing & Capping and all accessories, with 1 run of 6 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper/ Emulsions matching to the existing colour/ quality of walls/ floors/ ceiling etc. complete all as specified and directed. Note- Five run of cable and one run of PVC casing and capping shall be measured as one unit.

400

-

-

... More
All as per item No 25 here-in-before but 4 runs of 10 sqmm single core FRLSH copper conductor and 1 run of 10 sqmm conductor for earthing. Note :- 5 runs of 10 Sqmm cable and one run of PVC and capping with accessories shall be measured as one unit.

300

-

-

... More
All as per item No 25 here-in-before but 2 runs of 6 sqmm single core FRLSH copper conductor and 1 run of 6 sqmm conductor for earthing . Note :- 3 runs of 6 Sqmm cable and one run of PVC and capping with accessories shall be measured as one unit.

500

-

-

... More
All as per item No 25 here-in-before but 2 runs of 4 sqmm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing. Note:- 3 runs of 4 Sqmm cable and one run of PVC and capping with accessories shall be measured as one unit.

500

-

-

... More
S&F Sheet Metal Enclosure for MCB DB, TPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.

3

-

-

... More
S&F Sheet Metal Enclosure for MCB DB, TPN, 6 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.

5

-

-

... More
S&F Sheet Metal Enclosure for MCB DB, TPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.

5

-

-

... More
S&F Sheet Metal Enclosure for MCB DB, SPN, 12 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.

3

-

-

... More
S&F Sheet Metal Enclosure for MCB DB, SPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.

10

-

-

... More
S&F Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.

5

-

-

... More
S&F in repair , MCB, TPN, 100 Amps, 415 Volt, b curve, having breaking capacity 10 kA complete all as specified and as directed.

20

-

-

... More
S&F in repair , MCB, TPN, 63 Amps, 415 Volt, b curve, having breaking capacity 10 kA complete all as specified and as directed.

20

-

-

... More
S&F in repair , MCB, TPN, 40 Amps, 415 Volt, b curve, having breaking capacity 10 kA complete all as specified and as directed.

20

-

-

... More
S&F in repair MCB, TP, 100 Amps, 415 Volt, B curve, having breaking capacity 10 kA, complete all as specified.

20

-

-

... More
S&F in repair MCB, TP, 63 Amps, 415 Volt, B curve, having breaking capacity 10 kA, complete all as specified.

20

-

-

... More
S&F in repair MCB, SPN, 63 Amps, 415 Volt, b curve, having breaking capacity 10 kA complete all as specified and as directed.

100

-

-

... More
S&F in repair MCB, SP, 6-32 Amps, 240 Volt, b curve, having breaking capacity 10 KA complete all as specified and as directed.

500

-

-

... More
S&F Sheet metal enclosure Vertical TPN for DB's when MCCB's to be used 4 way with 250 amps bus bar double door IP 43 metal door complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
All as per item No. 42 above but for DB's when MCCB's to be used 6 way complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
All as per item No. 42 above but for DB's when MCCB's to be used 8 way complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
S&F in repair MCCB, 4 Pole, 250 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

6

-

-

... More
S&F in repair MCCB, 4 Pole, 200 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

6

-

-

... More
S&F in repair MCCB, 4 Pole, 160 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

6

-

-

... More
S&F in repair MCCB, 4 Pole, 100 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

6

-

-

... More
S&F in repair MCCB, 4 Pole, 63 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

20

-

-

... More
S&F in repair MCCB, 3 Pole, 250 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

6

-

-

... More
S&F in repair MCCB, 3 Pole, 200 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

6

-

-

... More
S&F in repair MCCB, 3 Pole, 160 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

5

-

-

... More
S&F in repair MCCB, 3 Pole, 100 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

8

-

-

... More
S&F in repair MCCB, 3 Pole, 63 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.

8

-

-

... More
S&F in repair 36 Watt LED Building Security light Industrial with PDC housing having IP 65 protection including taking old light fitting complete all as specified.

60

-

-

... More
S&F in repair Regal Batten for LED tube lights, both side connection type and LED tube rod 1 x 20 Watt, both side connection all as specified and as directed.

800

-

-

... More
S&F in repair LED light fitting 20 W, high performance batten , 220 volt ,50 Hz,6000 k surface mounted high quality extruded polycarbonate ,environmental friendly ,energy efficient , with all connecting accessories ,with suitable connection complete all as specified and directed by Engr-in-Charge. Make:- Havells or equivalent any other manufactures from the approved list

500

-

-

... More
S&F in repair Blaze high bay LED light 100 Watt ,240 volt , All as specified and directed.

80

-

-

... More
S&F in repair 50 Watt LED Flood Light having IP-66 protection, pressure die cast aluminium housing, high luminous efficacy and high power complete all as specified.

40

-

-

... More
S&F in repair 80 Watt LED Flood Light having IP-66 protection, pressure die cast aluminium housing, high luminous efficacy and high power complete all as specified.

4

-

-

... More
S&F in repair 100 Watt LED Flood Light having IP-66 protection, pressure die cast aluminium housing, high luminous efficacy and high power complete all as specified.

4

-

-

... More
S&F in repair 150 Watt LED Flood Light having IP-66 protection, pressure die cast aluminium housing, high luminous efficacy and high power complete all as specified.

4

-

-

... More
S&F in repair LED tube light 1x20 W both side connection type all as specified and directed in repairs of conventional tube rods, ballast etc.

2100

-

-

... More
S&F in repair 18 watt LED PLL lamp by disconnecting and removing the old choke, starter from the existing fitting with necessary internal wiring from holder to terminal box inside the fitting complete all as specified.

40

-

-

... More
S&F in repair 12/15 Watt recessed mounted, round/square shaped LED down lighter with high luminous LED for indoor application with all accessories and connection to the electric circuit including taking down old light fitting complete all as specified.

200

-

-

... More
S&F in repair 12 to 15 watt surface mounted LED Square down lighter with high luminous LED for indoor application with all accessories and connection to the electric circuit including taking down old light fitting complete all as specified.

200

-

-

... More
S&F in repair LED aviation obstruction light luminaires, comprising of aluminium housing LED bulb , with polycarbonate enclosure including taking down old light fitting complete all as specified.

15

-

-

... More
S&F in repair 36 Watt LED recessed mounted panel lights (600x600mm size) luminaires, comprising of aluminium housing with polycarbonate enclosure including taking down old light fitting complete all as specified.

180

-

-

... More
S&F in repair 36 Watt LED surface mounted panel lights (600x600mm size) luminaires, comprising of aluminium housing with polycarbonate enclosure including taking down old light fitting complete all as specified.

30

-

-

... More
M&L in repairs Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron strip 25x3 mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c, 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc. including testing on completion complete all as specified. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50m (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.

20

-

-

... More
M&L in repair aluminium strip 25 x 3 mm with porcelain insulators, saddles and fixing screws etc. for roof conductor and down conductor above ground all as specified and directed.

200

-

-

... More
M&L in repair air termination single pointed aluminium rod 12mm dia and 300mm long all as specified and directed.

30

-

-

... More
M&L for test point terminal block made of gunmetal of size 75x75x25mm drilled and screened including all fixing arrangements with hexagonal headed screws and taking down old ones complete all as specified.

20

-

-

... More
S&F in repairs PVC junction boxes for accommodating test point of lightening arrestor syntex make all as specified and directed.

20

-

-

... More
Equipment and labour for testing of earth resistance of existing earthing of lightening arrestor of building /workshop/hanger /OTM etc. at Naval Base Kochi .

600

-

-

... More
S&F in repairs Modular Bell push 6A, 1module, complete all as specified.

30

-

-

... More
S&F in repairs in repair Fan Regulator, modular electronic rotary, 0-4 steps step type 100Watt, 240 Volt 50 Hz hum free 2 module complete all as specified.

60

-

-

... More
S&F in repairs switch modular 6 Amps 240 Volts one way switch complete all as specified.

20

-

-

... More
S&F in repairs Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type complete all as specified.

20

-

-

... More
S&F in repairs Socket 6A/ 16 Amps 2/3 pin combined AC 240 Volt modular type complete all as specified.

20

-

-

... More
S&F in repairs Switch modular type AC 240 volts 16 Amps one way complete all as specified.

10

-

-

... More
S&F in repair 10 Watt LED Mirror Lamp, 240V, surface mounted decorative mirror optic type with engineered plastic body and including tube rod and connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal including taking down old light fitting complete all as specified.

100

-

-

... More
S&F in repairs, SPN Enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug, complete all as specified and directed.

40

-

-

... More
M&L XLPE insulated heavy duty electric cables 10 sqmm 4 core with aluminium conductor, 1100 volts grade, including taking down old unserviceable cable complete all as specified and directed.

100

-

-

... More
All as per item no.84 hereinbefore but for 16 sqmm 4 core cable.

100

-

-

... More
All as per item no.84 hereinbefore but for 25 sqmm 4 core cable

100

-

-

... More
All as per item no.84 hereinbefore but for 10 Sqmm 2 Core cable

100

-

-

... More
All as per item no.84 hereinbefore but for 16 Sqmm 2 Core cable

100

-

-

... More
All as per item no.84 hereinbefore but for 50 Sqmm 3.5 Core cable

100

-

-

... More
S&F energy efficient ceiling fan of 1200mm sweep, BLDC 230 Volt 50 Hz including all electrical connection complete all as specified and as directed by Engr-in-Charge. make :- Havells or equivalent any other manufactures from the approved list including taking down old unserviceable ceiling fan and depositing with MES Store yard

150

-

-

... More
Taking down existing ceiling fans of 1200 mm sweep of any make and removing to workshop for following repairs and refixing at same location/ other location directed by Engineer-in-Charge:- (a) Opening & Strip cutting the winding of ceiling fans and re-winding with super enamelled copper wire of suitable/ existing size, with sleeves, heating, baking etc. and re-assembling the same. (b) Replacement of Ball bearings of suitable size. (c) Replacement of fan capacitor of suitable capacity. (d) Replacement of split pin, Nickel plated mild steel clamps, nuts, bolts washer suitable for any make & type ceiling fans (e) Rubber real insulator with clamps, bolt, nuts and split pin (f) Screws of suitable size for blades & body

400

-

-

... More
All as per item No. 91 above but for exhaust fan 250 to 450 mm sweep

100

-

-

... More
All as per item No. 91 above but for flame proof exhaust fan of any sweep

40

-

-

... More
All as per item No. 91 above but metal body wall mounted fan of 450 to 600 mm sweep

40

-

-

... More
All as per item No. 91 above but Air circulators 600 to 900mm sweep

40

-

-

... More
Taking down existing PVC body wall mounting fans of any make, type & servicing complete including well cleaning, removing of rust, dust etc. replacing of motor of suitable type & capacity of any make complete and making good in working condition all as specified & directed.

20

-

-

... More
Supply & fix PVC body wall fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in-Charge

40

-

-

... More
S&F in repairs of PVC body exhaust fans complete 200/250mm sweep on the same location or where as directed by Engr-in-Charge.

40

-

-

... More
S&F 450mm sweep, metallic body exhaust fan heavy duty, single phase 230 Volts, complete all as specified and as directed by Engr-in-Charge. Make: Havells Cat Part No. or equivalent any other manufactures from the approved price list. Note : Old fan will be deposited in MES store yard

40

-

-

... More
M&L for repair to existing flame proof tube light fittings & replacement of unserviceable tube rods after opening, removing the existing tube rods, ballasts etc. with LED tube rods of 1x20 Watt complete all as specified and as directed.

40

-

-

... More
S&F in repairs flame proof rotary switch 10 to 16 Amps complete all as specified and as directed.

20

-

-

... More
S&F in repairs flame proof rotary switch 16 to 25 Amps complete all as specified and as directed.

10

-

-

... More
S&F in repairs driver assembly for LED fittings (Indoor or Outdoor type) for light fittings (Street light, High Bay light, Flood light) from 30 to 150 Watt of any make and type with existing type driver assembly all as specified and as directed.

200

-

-

... More
S&F in repairs for driver assembly suitable for 2 feet x 2 feet of 36/40 Watt ceiling fittings surface mounted / recess mounted (Indoor Or Outdoor type) of any make for suitable to the existing light fittings of any.

100

-

-

... More
S&F in repairs surface type LED fittings 5/8 Watt round/ square type of existing make and type

120

-

-

... More
S&F in replacement of LED bulbs of obstruction light at any height complete all as specified and as directed.

50

-

-

... More
M&L for checking of ceiling fan stability / tightness with fan hook for Garuda, SFNA, MO(K) and NAY (K) or other specified areas as directed and make good, re-tightening of split pin / nut, bolt etc., ,loose connection in distribution boards, MCBs all as per site requirement complete all as specified and directed. Note:- (i) The cost of accessories like split pin, nuts, bolts, washers etc. if any required shall be included in the quoted rate. The quoted rate shall inclusive of all labour and plants like ladder etc. complete. (ii) The contractor shall maintain a register showing the location of fan duly signed by the users for the service carried out. This register shall be produced while claiming payment. (iii) The checking of fans shall be carried out once in 6 months. (iv) Checking of 7 fans and 2 DBs of any type at a time is shall be considered as one job.

4800

-

-

... More
Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation) like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration, checking of variation of R Y B phase in LT panel/DBs ,changing of MCBs, small pieces of wires including connections etc. carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like repair of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at Garuda, SFNA, MO(K) and NAY (K) or other specified areas at Naval Base during working hours (0900 hrs morning to 0900 Hrs evening ) on all working days all as specified and directed by Engineer-in-Charge. (Refer Notes)

300

-

-

... More
Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation) like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration, checking of variation of R Y B phase in LT panel/DBs ,changing of MCBs, small pieces of wires including connections etc. carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like repair of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at Garuda, SFNA, MO(K) and NAY (K) or other specified areas at Naval Base during off hours (1700 hrs evening to 0900 Hrs morning ) on all working days all as specified and directed by Engineer-in-Charge. (Refer Notes)

100

-

-

... More
Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation) like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc. carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like replacement of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at Garuda, SFNA, MO(K) and NAY (K) or other specified areas area at Naval base during off days including Sunday and holidays all as specified and directed by Engineer-in-Charge. (Refer Notes)

100

-

-

... More
NOTE for item no. 108 to 110:- (i) The material and labour cost required for taking down existing fitting / fixture and fixing of new item shall be measured and paid separately under relevant item. Additional labour charge required for immediate attendance of complaint only shall be quoted under this item. (ii)The technician employed by the contractor shall available on all working days. The quoted rate shall inclusive of all labour, transportation of material and tools. (iii) The contractor shall display contact number of technicians in 'E' area at Naval Base to register users complaint. (iv) A penal recovery of Rs. 800/hour/complaint shall be effected on contractor beyond 3 hrs. A register shall be maintained by contractor duly countersigned by Concerned JE & AGE with time of occurrence of defect and time of rectification and submitted for claiming payment.. (v) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly including all aspects like labours ,tool, transportation etc

-

-

-

... More
Material, Labour, tools & equipments required for re-fixing / Replacement of repaired light fittings any type, at any location, height exc 7m with the help of Crane etc.in Hangars, Workshops etc. All as directed. Note:- The cost of replacement of light fitting shall be measured and paid separately. The additional labour / accessories cost reqd for working at height more than 7m shall be quoted under this item.

100

-

-

... More
Taking down Exhaust fan of metal body of any type & size and painting by spraying in existing colour (synthetic enamel paint) including louvers and re-fixing as specified and as directed location.

100

-

-

... More
Taking down Wall mounting fan of metal body of any type & size and painting by spraying in existing colour (synthetic enamel paint) including louvers and re-fixing at specified and as directed location.

30

-

-

... More
Taking down Ceiling fans of 1200/1400 mm of metal body of any type & size including down rods and painting by spraying in existing colour (synthetic enamel paint) including louvers and re-fixing at specified and as directed location.

250

-

-

... More
Periodical servicing and maintenance (monthly) of electric operated hangar door comprising of 3 phase, 415V, 5.5 KW/ 3 HP, 50 Hz IP 55 capacity induction motor of Make - Havells,3 HP VFD panel, connected with gearbox through chain, push button for forward/ reverse movement of the doors, relays, limit switches, contactors gear wheels, siren, ammeter and voltmeter, indicating lamps, various capacities of MCBs and suitable connecting cable etc. complete all as specified and directed by Engineer-in-Charge. Location : INAS 550 - 10 Nos motors and connecting items.

12

-

-

... More
Notes for item No.115:- (a) All tools / plants / equipments required for maintenance of Hanger Door shall be provided by the Contractor. (b) Cost of nut, bolt, washers, etc. of suitable size as required shall be included in the quoted rate. (c) Any complaint of the Hanger Door shall be attended within 2 hours from intimation, other wise a penal recovery of Rs. 2000/- per hour shall be effected. (d) Replacement / refilling of gear oil in gear boxes is deemed to be included in the scope of item. The cost of gear oil, grease, cotton waste etc shall be included in the quoted rate.

-

-

-

... More
S&F Electric motor 3 HP, 415 Volt, 50 Hz IP 55 protection suitable for operating Hanger Doors forward and reverse motion of same existing model (of Havells) including taking down old motor complete all as specified and directed

2

-

-

... More
Rewinding of Hangar Door electric motor obtained as per Sl No. 116 above including strip cutting, rewinding of the motor with super enamelled copper conductor of existing size and gauge including heating, baking, replacement of bearings etc. and re-assembling motor complete and testing complete all as specified and as directed.

1

-

-

... More
Taking down existing gear box assembly of Hangar Door motors and removing to workshop for servicing and refixing in the same location complete all as specified and directed.

5

-

-

... More
Taking down existing 4 x 2.5 sqmm flexible wire from control panel to motor and S&F flexible cable 4 x 2.5 sqmm at any height complete all as specified and directed.

300

-

-

... More
S&F in repair of existing size PVC cable runner for smooth running of cable at any height complete all as specified and as directed.

150

-

-

... More
S&F in repair of Contactor 240 Volt complete all as specified and as directed.

5

-

-

... More
S&F in repair of Relay 6 to 10 Amps complete all as specified and as directed.

5

-

-

... More
S&F in repair existing type hooter assembly complete all as specified and as directed.

2

-

-

... More
S&F in repair existing type flash assembly complete all as specified and directed.

2

-

-

... More
S&F in repair existing type emergency switch complete all as specified and directed.

2

-

-

... More
M&L General servicing of 1.5/2.0 TR capacity inverter split type AC indoor unit and outdoor unit, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water at same location, replace the unserviceable parts if any commissioning complete through OEM all as directed.

3

-

-

... More
S&F in repairs, Hermatically sealed compressor unit suitable for Window / split type AC of 1.5 Ton capacity in exchange of the existing unserviceable sealed compressor unit including connecting up complete all as specified & directed. Make:- Samsung/ Toshiba/ Godrej/ Kirloskar/ make as per site requirement.

3

-

-

... More
S&F in repair cooling coil made out of Copper tube suitable for indoor unit of Split Air conditioner of any capacity all as per specified and as directed.

3

-

-

... More
Supply and replace Fan motor 1/5 HP 240 Volt suitable for outdoor unit of split type AC of any capacity, make or model all as specified and as directed.

3

-

-

... More
S&F in repair Fan blade suitable for Outdoor unit of Split type AC of any capacity, make or model all as specified and as directed.

3

-

-

... More
S&F in repair indoor Prime Control Remote Board including sensors and temperature digital display sensor suitable for LLYOD cassette type AC of Model No. LS48SS all as specified as per site requirement.

3

-

-

... More
S&F Refrigerant Gas -R-22 all as specified.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.