Military Engineer Services Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical Cables And Wires
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Jan 2025
Closing Date1 Feb 2025
Tender Amount₹ 37,45,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm.

136.5

-

-

... More
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.

42.5

-

-

... More
M&L for cushioning for protection of cable using dry river sand, free from particles all as specified and directed.

48.3

-

-

... More
M&L for Protection to cable with one layer of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm laid flat butting to each other in such a way that the length of the cable cover is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks/fly ash bricks all as specified and directed by Engr-In-Charge.

1944.4

-

-

... More
M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of poles above ground leve including finishing to exposed concrete surfaces even and fair and provision of form work for rough finished surfaces complete all as specified

1

-

-

... More
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 185 sq mm complete all as specified.

350

-

-

... More
M&L for cable jointing kit 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. (Note : Excavation & earth work, sand cushioning, coverslab for protection if necessary will be measured and paid sepatately)

2

-

-

... More
M&L for cable jointing kit 11 KV (Earthed) grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. (Note : Excavation & earth work, sand cushioning, coverslab for protection if necessary will be measured and paid sepatately)

2

-

-

... More
Supply and lay in trenches/under roads/crossings are fixed to wall/pole, GI tubing light grade of 100 mm dia sizes for protection of UG cables including taking out of old unsv GI pipe. Note : Payment for excavation and earth work shall be paid for separately under relevant items of Schedule.

6

-

-

... More
Material and labour for boring of holes under road,pavement,hard standing by trenchless technology using ultra sound technique and necessary machine including provn of HDPE pipe 110 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by Engr-In-Charge. Note:- Quoted rates deemed to be inclusive of transportation charges of drilling machine,connected accessories ,HDPE pipe,statuatory charges for road cutting.

10

-

-

... More
S&F HT Cable route marker of Cast Iron which dia 150 mm and angle iron of 25 x 25 x 4 mm and 1 ft length including all connecting accessories like nut, bolts and washer and burried in ground with PCC (1:2:4) size 100 x 100 x 150 mm complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Earthing complete with galvanised galvanised steel plate electrode of size 60cm x 60cm x 6 mm thick, buried vertically in a earth pit not less than 2.25 metre deep below ground level with top edge of plate not less than 1.5 metre below normal ground level surrounded by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip of size 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, and earth strip protected by GI protection pipe light grade 40 mm bore connected to main earth lead on control panel board and GI pipe light grade 20mm bore for watering, funnel with wire mesh. PCC chamber in PCC 1:3:6 type C-1,40mm thick precast RCC 1:2:4 type B1 (Design Mix) cover reinforced with 8mm dia TMT bars @ 10cm C/C on both sides and handle complete Excavation and earth work in any type of soil and removal up to 50M complete all as specified and shown in electrical plate No:3 of SSR-I (2009) connecting to earth test point on completion. Note: Earth Resistance shall not exceed more than three ohm.

4

-

-

... More
Supply ,Install TestIing and commissioning of outdoor type HT ,12 KV 630 Amps SF 6 insulated RING MAIN UNIT (RHS EXTENSIBLE) CRCA material duly powder coated RAL 7032 with min 80 Micron Thickness and thckness of material 2 to 2.5 mm thck for load bearing and 1 to 1.6 mm for non load bearing, Degree of protection for Tank-IP 67 (SS Tank Thckness 2mm), Mechanism Chamber IP 2X in Canopy door open condition, cable Chaber IP 3X in Canopy door open condition,Outdoor IP 54 in Canopy door close condition Busbar rating 630 A,STC 21 kA/3s, dielectric withstand 28kV AC/1 minute,Impulse Withstand 75 kVP,Rated Peak Current 52.5kAP,Rated Frequency 50 Hz with 01 No LBS for incomer of capcity 12 kV 3 phase 630 A, 21kA/3s and 03 Nos vaccum circuit breaker of capacity 12 kV 3 phase 400 A 21 kA/3s in single panel, as per manufacturer design and comprising of the followings parameters :- ( Make as per Schneider Electric Varient FBX-E/12-21/M+CT2+T2T2-OUTDOOR MANUAL or Equivalent from make list) Incomer :- Load Break switch 12 kV,21kA/3s 3 pole with 3 pole manual earth switch-01 No Outgoing:- Vaccume circuit breaker 12 kV,21 kA/3s 3 pole with 3 pole manual disconnector, 3 pole manual Earth switch,low energy trip coil, mechanical emergency push button and counterwith current rating of breaker 400 A.- 03 Nos

1

-

-

... More
Voltage presence Indicator:- suitable for 10-24 kV LED type as per IEC 61958. Manometer:- Multiscale to cover 1.3 Bar(absolute ) or 0.3 Bar (relative)@20 deg C.-02 Nos. Cable Boot:- Push on type suitable for XLPE cable Al 1 Rx3C upto 300 Sqmm- 04 Sets. Relay: Base mounted LED display 3 pole overcurrent + earth fault relay with selectable characteristics for breaker feeder with RS 485 port on MODBUS protocol and following setting ranges :- I:0.2 to 2.5,t:0.1-150s in steps of 0.01s&ti:0.01-1.500 in steps of 0.005:I:0.5to 30,t:0.03-20s in steps of 0.01s Ie:0.05 to 2.5,te0.05-150s in steps of 0.01s &tie :0.01-1.500 in steps of 0.005:Ie:0.5 to 15,te:0.04-20s in steps of 0.01s (03 Nos) Indication lamp : All LED lamps . Current Transformer : CT1 Tape Wound Core 1: 50-100/1A,Class:SP10,2.5VA Core 2: 50-100/1A,Class:1.0,2.5VA for protection and metering -03 Sets Current Transformer : CT2 Core 1: 100-200/1A,Class:SP10,2.5VA for metering -01 Set TVM : 3 PH,4Wire,110VAC,1AMP for incoming feeder CT ratio-100-200/1A,PT Ratio-11kV/rt3/110/rt3,Accuracy Class 0.5 base mounted incl RS 485 port on MODBUS protocol-01 No

-

-

-

... More
Digital Ammeter: 96x96 Sqmm,3Phase digital Ammeter with Aux supply :90to 300 V AC accuracy class 1-03 Nos Potential Transformer: 11 kV /rt3/110V/rt3,resin cast PT with fuse on primary,Voltage factor -1.2 cont.&1.9 for 8 Hrs,3Phase,accuracy Class-05 Burden 50 VA-01 No for metering Space Heater: Strip Type 230V AC 80 W-01 No Thermostat: Spring Type 230V AC,Range 30-110 Deg C,10 A,SUN-110-01 No Phase indicating LEDs-63.5V AC(L-N),23 mm dia LEDs-01 Set Ambient temperature -5 to +40 deg GAS Pressure: Operating: 1.3 Bar(Absolute)or 0.3 Bar (Relative) at 20 deg C. Note : RMU Shall be mounted on PCC platform suitable height as per OEM direction inccl necessary grouting arrangements all as specified. Rate quoted by the contractor deemed to be inclusive of PCC platform and all other necessary work for the satisfactory commissioning of RMU with HT supply .

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.