Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 19,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681661_1Tender No
8980/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
(c) One 3 pin socket outlet 5 Amps on Independent board
12
-
-
(d) One 3 pin socket outlet 5 Amps on same board
5
-
-
(e) One bell point controlled by one bell push
4
-
-
All as per Item No. 2 above but with 4 sq mm PVC insulated copper conductor cable(FRLS) including 4 sq mm PVC copper conductor used as earth wire for power point on independent board for One 3 pin socket outlet, 15 Amps.
15
-
-
Supply and fix in repairs Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed.
30
-
-
Supply and fix in repairs Switch Socket Combination 2 in 1, 5pin 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
12
-
-
Supply and fix in repairs Switch Socket Combination 2 in 1, 5 Amps /16 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
15
-
-
Supply and fix in repairs Socket outlet 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
5
-
-
Supply and fix in repairs electronic fan regulator, 450W 250V stepped type, flush type complete all as specified and as directed.
5
-
-
Supply and fix in repairs Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed.
8
-
-
Supply and fix in repairs Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed.
4
-
-
Attending internal/ external electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in internal electric wiring/circuit, LT panels/ meter panel, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge.
Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid.
(b) The spares required for the rectification of fault shall be measured under relevent items of BOQ.
(c) Five(05) numbers of complaint shall be measured as one unit(Each Job)
240
-
-
Supply only Switch piano, flush type, single pole, one way 5 Amps, 230 volt AC with ISI marked complete all as specified and directed.
40
-
-
Supply only Socket outlet 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
40
-
-
Supply only Socket Combination 2 in 1, 5 Amps /16 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
30
-
-
Supply only Bell electric ding dong 230 V complete all as specified and directed.
10
-
-
Supply only Bell push 5 Amps one way complete all as specified and directed.
10
-
-
Supply only Electronic fan regulator 230 volts, step type,socket type, hum free 120 watt ISI Marked complete all as specified and directed.
30
-
-
Supply only Ceiling rose in poly carbonate 3 phases flush type 6 Amps, 230 volts AC complete all as specified and directed.
15
-
-
Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fitting complete all as specified and directed.
10
-
-
Supply only of Modular switch, one way, 6Amps complete all as specified and directed.
25
-
-
Supply only Modular switch, one way, 16Amps complete all as specified and directed.
20
-
-
Supply only Modular switch, two way, 6 Amps complete all as specified and directed.
6
-
-
Supply only Modular socket outlet, 6 Amps, 2 and 3 pin combined complete all as specified and directed.
20
-
-
Supply only Modular socket outlet, 6 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed.
20
-
-
Supply only Modular fan regulator step type, 120 Watt complete all as specified and directed.
15
-
-
Supply only Modular Bell push, 6 Amps complete all as specified and directed.
10
-
-
Supply only Modular switch socket combination 16 A 6 pin 3 Module complete all as specified and directed.
10
-
-
Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed.
Make: Cat No QHPCWC5002X5 of Havells or equivalent in L&T/Surya
40
-
-
Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed.
Make: Cat No QHPCWC5004X0 of Havells or equivalent in L&T/Surya
25
-
-
Supply only in replacemet LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Make: Bajaj / Havells/Philips/Crompton Greaves.
85
-
-
Supply only in replacement of LED bulb 9 watts, 230 volt, provides upto 4 Hrs backup 2200 mAh Li-On Battery for Longer Product Life,Protection Shield : Overcharge, Deep Discharge & Short Circuit Protection 100 Lumens Per Watt Surge Protection Upto 4Kv Voltage Protection upto 440V complete all as specified and directed. Make: Crompton Cat part No. LED9WDFINVNB4DCDL or equivalent in Philips/Bajaj/Havells.
50
-
-
Supply only MCB single pole & neutral 240 volt C curve 10 KA 40 Amps capacity IP 20 transparent lebel holder fully insulated safety shutters complete including suitable size copper lugs complete all as specified and directed.
14
-
-
All as per ser item No 32 above but MCB TPN 415 volt C curve 10 KA 40 Amps capacity complete all as specified and directed.
10
-
-
All as per ser item No 32 here-in-before but MCB single pole, 6 to 32 Amp 240 volt B curve 10 KA complete all as specified and directed.
30
-
-
Supply only energy efficient LED building security light fitting 35W on existing brackets including connection with twin core flexible pvc 0.5 sqmm cable complete all as specified and as directed.
Make: Crompton/Philips/Bajaj/Havells.
12
-
-
Material and labour for Sub main wiring using two runs of single core PVC insulated cable (FR) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC Casing and Caping including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 3 run of 6 sq mm PVC copper wire and One run of PVC casing caping shall be measured and paid as one unit.
70
-
-
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 415 volts, MCBs used as incommer Double door, flush to wall complete all as specified and directed .
2
-
-
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 4 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed.
5
-
-
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed.
5
-
-
Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with one MCB single pole 20 Amps complete all as specified and directed.
12
-
-
Taking down ceiling fan of any type and size, cable ends, dimantling blades and removing fan and balde to store yard and Hanging/ fixing only repaired/ reconditioned Fan of any type and size and connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed.
60
-
-
Collecting unserviceable ceiling fan 1200/1400mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceable winding from fan stater & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed.
Note : (i) Taking down and refixing after repair work shall be measured and paid under Item No.42 above.
(ii) Spare such as Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps etc shall be measured & paid separatetly under item Nos.49 to 56.
40
-
-
All as per item No 42 above but exhaust fan 300 mm sweep
10
-
-
All as per item No 42 above but exhaust fan 250 mm sweep
5
-
-
All as per item No 42 above but wall fan 450 mm sweep
5
-
-
Material and labour for Scraping down old paint of ceiling fan of any size sweep complete body & blade including down rod filling the cavities with filler and making smooth surface by applying two coats of synthetic enamel paint over a coat of primer after prepation with sand paper by means spray gun/brush with all as specified and as directed.
30
-
-
Supply only only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL
20
-
-
Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample
20
-
-
Supply only Gun metal bush for ceiling fan complete all as specified and directed.
15
-
-
Supply only Down rod 300 mm long of size 20 mm dia ISI marked complete all as specified and directed.
4
-
-
Supply and fixing Oscillating mechanism suitable for wall mounting fan any make and type all as directed by Engineer-in-charge.
2
-
-
Supply and fixing in repair of Exhaust fan Motor of 300mm sweep heavy duty complete as per sample complete all as specified and as directed.
3
-
-
All as per item No 52 above but for 250mm sweep.
3
-
-
Supply and fix in repairs LED recess suitable for false ceiling 2 ft X2 ft, 40 watts , 240 volts AC supply complete all as specified and directed. Make : Cat part No CLLC-RMLSS-40 of CELS or or Equivalent in Crompton Greaves / Havells.
18
-
-
M&L for servicing incl cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for split type AC of any make/ capacity after taking down the whole unit and refixing at the existing location or any other new location after servicing all as specified and directed by Engr- in- Charge . (Note: S&F spare parts will be measured and paid separately under relevant item.)
17
-
-
Supply and fix in replacement of Printed Circuit Board suitable for 1.5/2TR Capacity Split Unit Air Conditioners including remote, etc. Make LG/equivalent as approved by GE
4
-
-
Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer. Make : LG/ Voltas/ Samsung complete all as specified and directed.
2
-
-
M&L for Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer.
2
-
-
Supply and fix in repairs AC blower fan motor for AC suitable for 1.5 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed.
3
-
-
Supply and fix in repairs AC blower fan motor for AC suitable for 2 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed.
3
-
-
Supply and fix in replacement of Capacitor 45 MFD complete all as specified and as directed.
Make : Cat Part No QHLIDC545006 in Havells or equivalent in L&T/Surya
6
-
-
Supply and fix in replacement of Capacitor 50 MFD complete all as specified and as directed.
Make : Cat Part No QHLIDC550006 in Havells or equivalent in L&T/Surya
6
-
-
Supply and fix of insulation Nytrile foam insulation suitable for 5/8 inch copper tube as per site requirement of approved make all as specified and directed .
10
-
-
Supply and fix of insulation Nytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved make all as specified and directed .
10
-
-
Supply and fix in replacement of Copper tube 5/8 inch size as per site requirement of approved make all as specified and as directed.
10
-
-
Supply and fix in replacement of Copper tube 1/4 inch size of approved make all as specified and directed .
10
-
-
Supply and fix in replacement of Evaporator unit (indoor unit ) complete suitable for 1.5TR Capacity Split type Air Conditioners all as specified and as directed. Make : LG/ Voltas/Goderj
3
-
-
Supply and fix in replacement of Condensing (Out door) unit complete including compressor, etc. Suitable for 1.5TR Capcity Air conditioners all as specified and as directed. Make : LG/Voltas/Goderj/Total line/Techmesh
2
-
-
Supply and charging R-134A/ R-410A gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces complete all as specified and as directed.
20
-
-
Taking down carefully geyser of any make and capacity 25/50ltrs, dismantling the geyser for inspection, cleaning of tank, repalcement of defective part such as heating element, thermostat switch, spacer ring, safety plug, glass wool, neon lamp, head assembly, rubber gasket, top and bottom cover, inspection plate, copper cable 3 core, 3 pin Top plug, element holding clamp, welding of studs for head assembly, defective inner and outer shell reassembling the geysers with one coat of milky white synthetic enamel spray paint of approved quality after cleaning of all dust rust etc and writing of MES No on the geyser using black paint, Reinstallation of geysers to its original postion complete all as specified. Note : Spare parts such as heating element thermostat switch, spacer ring, heon lamp, head assembly, glass wool, safety plug rubber, gasket, copper cable, top & bottom cover, inspection plate, CP & PVC connection, Plug Top, Outer & Inner shell element holding clamps etc shall be measured & paid for seperately in respective items here in after.
10
-
-
Supply only heating element any type (i.e; Cup,thread or triangular) 1.5 KW, 220/230 volts ISI marked complete all as specified and directed.
5
-
-
Supply only Thermostat ISI marked complete all as specified and complete all as specified and as directed .
3
-
-
Supply only Head Assy "Brass" 8 to 9 holes suitable for 25 ltrs capacity all complete all as specified and as directed .
3
-
-
Supply only geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity all as specified and complete all as specified and as directed .
3
-
-
Supply and fixing in repairs non return brass valve of 15mm bore, ISI marked complete all as specified and as directed .
3
-
-
Supply only PVC connections 15mm size for Hot and cold water connection with rubber washer & brass nuts, ISI marked of length 450mm complete all as specified and directed.
2
-
-
Supply and fixing in repairs Plug top 3 Pin 15 Amps 230 volts complete all as specified and as directed .
5
-
-
Schedule of Credit (Minus) Rs.26614.00 NOTE: Bidder shall insert credit amount of Rs. 26614.00 as rate in Green field under Col-13.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%