Military Engineer Services Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Jun 2024
Closing Date3 Sep 2024
Tender Amount₹ 9,20,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and charge following refrigerant gas as suitable for existing AC's/ Refrigerators and water cooler of any size/make including copper strainer and capillary tube etc as per site requirement including testing all as specified and as directed by Engineer in charge . Note: Nitrogen gas test shall be done prior to the filling and leakage if any shall be arrested.

-

-

-

... More
(a) R-32 Gas

68

-

-

... More
(b) R-410 A Gas

40

-

-

... More
Supply only Capacitor 36/45 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron)

18

-

-

... More
Supply only Capacitor 50/60 MFD suitable for 230V 50HZ AC supply all as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron)

19

-

-

... More
Supply only Capacitor 80/100 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron)

17

-

-

... More
Taking out existing burnt fan motor single phase 230 Volt from the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the following all as specified and as directed by Engineer - in - Charge.

-

-

-

... More
Split /window type AC capacity up to 1.5 Ton

11

-

-

... More
Split/ window type AC 2.0 Ton Capacity

16

-

-

... More
Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR

14

-

-

... More
Taking out old unserviceable PCB and replace the same with new PCB at site suitable for Tower AC of capacity 3/4TR ( Indoor/Outdoor) Make : LG/Blue star/Voltas or equivalent.

4

-

-

... More
Taking down unserviceable Window/Split Air Conditioner of any capacity make by un-screwing from base plate after disconnecting all electrical and suction / discharge pipe connections complete and making necessary repairs as required like fixing new compressor (sealed unit) and providing all electrical connections to respective terminals including changing of unserviceable connecting wires as per the existing. Brazing of suction and discharge lines with new compressor and vacuuming the system and testing/ rectification of leakage, fixing cooling coil, charging of refrigerant gas as per requirement to achieve proper cooling effect and testing after refixing in position complete all as specified and directed by Engr-in-Charge. Note:- Compressor (sealed unit), air cooling coil, condenser coil, Refrigerant Gas and spare parts required for replacement for satisfactorily repair shall be paid and measured separately under relevant items.

-

-

-

... More
Supply of factory made rotary type sealed compressor unit same as per existing model for window type AC capacity up to 1.5/2.0 Ton

2

-

-

... More
Supply of factory made rotary type sealed compressor unit same as per existing model for Split type Ac 1.5/2.0 Ton capacity.

3

-

-

... More
Taking out carefully existing defective sealed unit compressor for Refrigerator /Water Cooler and supply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge.

-

-

-

... More
Refrigerator capacity of 165/190/240/285/310 ltrs.

2

-

-

... More
Water cooler capacity of 40/80, 60/120 & 75/150 ltrs.

2

-

-

... More
M & L Sealed compressor unit suitable for 3-4 TR capacity 3 phase ductable split/Tower AC including first filling of refrigerant gas, compressor oil etc. testing and commissioning ,including taking down of old u/s one, all as specified and as directed. .

1

-

-

... More
M&L for removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge.

8

-

-

... More
M & L for refrigerant piping for Split type AC 1.5/2.0 TR and Tower AC 3.0/4.0 TR with nitrle rubber insulation between indoor and outdoor units for split/Tower Ac units exceeding for 3.0 Mtrs complete all as specified and as directed by Engineer in charge.

15

-

-

... More
M & L for PVC drain pipe upto 25mm for connecting to nearest drain lines including chasing, drilling passing through on wall / Terace complete all as specified and as directed by Engineer in charge.

30

-

-

... More
Taking out defective thermostat & supply and fixing new thermostat for refrigerator suitable for capacity of 165 / 286 / 310 Liters complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA.

6

-

-

... More
Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS.

20

-

-

... More
Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS.

23

-

-

... More
Supply only over load protector for window type AC/Split type AC complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL.

11

-

-

... More
Suply only split type AC indoor unit oscilation motor complete all as directed by Engineer - in - Charge.

7

-

-

... More
Supply only thermostat for split/Window type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA.

12

-

-

... More
Supply and fix replacement 240V 20 Amp single pole and earth enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp SP All as directed EIC .Make: Legrand , Equivalent in L & T/Indo Asian/ havells

30

-

-

... More
Supply and fix in replacement MCB 240 V 50 Hz AC 10 KA , of following rating with necessary lugs for incomming and outgong connections fixed on DB / Enclosure / Panel Boards after taking down the existing MCB of any Make/ rating .Make: MDS Legrand / Indoasian / L & T.

-

-

-

... More
MCB SP 20 to 32 Amp

10

-

-

... More
MCB SPN 32 to 63 Amp

10

-

-

... More
Taking out existing unserviceable flexible cable of any size & Supplying and fixing new copper flexible cable of the following sizes for Water coolers / Window type ACs / Split Acs/ Refrigerator/ Deep freezer etc complete all as directed by Engineer - in - Charge. Make: Poly Cab/Havell's/Finolex .

-

-

-

... More
Flexible copper cable, 3 core, 4 Sq.mm.

30

-

-

... More
Flexible copper cable, 3 core, 2.5 Sq.mm.

30

-

-

... More
Material and labour for spray painting, outdoor unit of 1.5 Ton / 2.0 Ton capacity split type A/C by two coat of spray painting using super enamel paint over one coat of anticorrosive primer including preparation of old surfaces by scraping etc complete all as specified and directed by Engineer - in - Charge.

10

-

-

... More
Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified and as directed.

15

-

-

... More
M & L Removing the Window/Split A/C /Tower AC unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and outdoor unit in position on fixing on wall/ floor as directed including piping refix the insulation ,Gas charging filling the cavities on wall setting of grills alignment complete including , testing & commissioning to the entire satisfaction of Engineer - in - Charge. Note:-topping of gas if required, it will be measured & paid under relevant item.

14

-

-

... More
S & F in repair, starting relay pin type,240V , suitable for Window / Split type AC of any capacity, make or model, all as specified and as directed.

10

-

-

... More
S&F in repair, PVC float valve assembly 15mm bore suitable for water cooler , all as specified and as directed.

6

-

-

... More
S&F in repair, 15 mm bore, lift cock tap, suitable for water cooler , all as specified and as directed.

6

-

-

... More
M & L , Voltage stabilizer 5 KVA by rewinding/replacing the main transformer and replacing PCB, sensing transformer, power realy, connector piece and testing on completion, all as specified and as directed.

10

-

-

... More
All as per item No. 32 here in above, but of 4KVA

10

-

-

... More
M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge.

12

-

-

... More
Repair /replacement of candle for water purifier of suitable size/make for water cooler of capacity 40/80Ltr,60/120Ltr and 75/150Ltr as specified and directed by Engineer in Charge.

10

-

-

... More
Supply and fixing plug top 16 Amp, 230 Volt.

20

-

-

... More
Attending the emergent complaint for any type / any time of cooling appliances such as AC of capacity 1 to 4 TR Both window and split type) , water cooler of capacity 40/80, 60/120 and 75/150Ltr and refrigerator of capacity 60 to 190 Ltr installed at technical area of NPOL Kakkanad, by providing one mechanic and one helper alongwith required tools.

200

-

-

... More
Taking Down The Old Sub Main Wiring And M/L For New Sub Main Wiring With 4 Run Single Core 6.0 Sq Mm PVC Unsheathed Copper Multistranded, FRLS Conductor Drawing Into And Including PVC Conduit Medium Grade Of Size Not Less Than 20 Mm Dia With All Fittings And Fixtures Like L- Bow,Saddles Etc Of White/Lvory Colour PVC Conduit Includinh Multi Stranded Copper Earth Conductor 6.0 Sq Mm Two Run As Earth Continuity Conductor All As Directed By Engineer In Charge. Note: 2 runs of main cable alongwith two runs of earth continuity conductor and pvc conduit shall be measured as on RM.

125

-

-

... More
Taking down the old sub main wiring and M&L for new sub main wiring with 2 run single core 4.0 sq mm PVC unsheathed copper multistranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow,saddles etc of white/lvory colour PVC conduit includinh multi stranded copper earth conductor 4.0 sq mm one run as earth continuity conductor all as directed by Engineer in Charge. Note: 2 runs of main cable alongwith one run of earth continuity conductor and pvc conduit shall be measured as on RM.

165

-

-

... More
S&F in repairs Swing motor for 1.5 TR / 2 TR indoor unit of split type air conditioner all as directed by EIC.

10

-

-

... More
S&F in repairs indoor unit blower fan for 1.5/2 TR Split AC all as specified and as directed by engineer in charge

5

-

-

... More
S&F ( in repairs) suction copper pipe line heavy duty ½” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.

20

-

-

... More
S&F( in repairs) discharge copper pipe line heavy duty 3/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.

20

-

-

... More
S&F in repair selector switch of window type AC complete all as specified.

3

-

-

... More
S&F in repair Display assembly for split Ac/window Ac of capacity 1.5 /2 TR complete all as specified & directed. (Make : as per existing make )

10

-

-

... More
S&F in repair sensor for indoor unit of split Ac of capacity upto 2.0 TR complete all as specified & directed.(Make : as per existing make )

20

-

-

... More
S&F in replacement, Push type tap copper alloy Chromium plated 15 mm bore complete all as specified & directed.

6

-

-

... More
Supply and fixing in repair/replacement of water drain-out tary stainless-Steel for water cooler any make /size with PVC waste pipe, pipe clamp complete all as directed.

5

-

-

... More
Supply only aluminium / hard PVC condenser fan blade of blower motor suitable for split type AC of 1.5 TR / 2 TR capacity complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
S&F of Lid gasket set (top & bottom) of required size suitable upto 300 ltrs capacity water coolers including taking out old worn out gasket set.

8

-

-

... More
M&L for disconnecting the unserviceable PCBs from existing LG (Dual inverter)/Hitachi/Voltas/ Panasonic make Inverter ACs of capacity 1.5/2 TR, and re-fixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
M&L for installation of water coolers after repair including connecting to water supply system and electrical system, properly testing for cooling, auto cut ON/OFF of the system, sound less & vibration proof working system complete all as directed and satisfaction of Engineer-in-Charge.

10

-

-

... More
Supply and fix replacement 240V 20 Amp single pole and earth enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp SP All as directed. Make: Legrand , Equivalent in L & T/Indo Asian/ havells

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.