Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Military Engineer Services - MES Tender
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date7 Nov 2024
Closing Date12 Dec 2024
Tender Amount₹ 40,00,00,000
Costs
EMD
₹ 15,00,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Summary
Engineering, Procurement And Construction (epc) For Provision Of Otm Accn For 02 Units
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682872_1Tender No
85178/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Note : Schedule 'A' Part - II to Part XVI are prepriced by MES, Bidders shall insert their lumpsum amount under column 6 only.
-
-
-
Lumpsum price worked out by the tenderer for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part-II
1
22121242
-
Lumpsum price worked out by the tenderer for SITE CLEARANCE AND DEVELOPMENT as listed in Schedule ‘A’ Part-III
1
1364619
-
Lumpsum price worked out by the tenderer for PROTECTIVE WORKS AND RETAINING WALL as listed in Schedule ‘A’ Part-IV
1
24756958
-
Lumpsum price worked out by the tenderer for ROAD/ PATH/ HARDSTANDING/ CULVERT as listed in Schedule ‘A’ Part-V
1
17484827
-
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI
1
1213808
-
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII
1
10762613
-
Lumpsum price worked out by the tenderer for SECURITY WALL/ COMPOUND WALL/ FENCING & GATE as listed in Schedule ‘A’ Part-VIII
1
13413376
-
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-IX
1
1612075
-
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-X
1
756855
-
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XI
1
4219256
-
Lumpsum price worked out by the tenderer for COOLING APPLIANCE as listed in Schedule ‘A’ Part-XII
1
240322
-
Lumpsum price worked out by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-XIII
1
351171
-
Lumpsum price worked out by the tenderer for AIR CONDITIONER as listed in Schedule ‘A’ Part-XIV
1
1886054
-
Lumpsum price worked out by the tenderer for MACHANICAL LAUNDRY as listed in Schedule ‘A’ Part-XV
1
23080
-
Lumpsum price worked out by the tenderer for DISMANTLING/ DEMOLITION as listed in Schedule ‘A’ Part-XVI
1
36845484
-
Schedule 'A' PART -XVII (MISCELLANEOUS ITEMS)
-
-
-
SITE CLEARANCE AND DEVELOPMENT
-
-
-
Grubbing up tree trunks exc.300cm and n.exc. 1000cm girth including cutting of trunk portion protruding over ground digging out roots filling holes and levelling of ground, stacking of serviceable material and removing of unserviceable material to a distance not exceeding 50m and clearing site, complete all as specified and as directed.
8
-
-
ROAD/ PATH/ HARDSTANDING/ CULVERT
-
-
-
S&F convex mirror 100cm dia traffic mirror in orange colour, unbreakable with nut and bolt, diameter with adjustable fixing bracket including necessary foundation and supports, etc., complete all as specified and directed by Engineer in charge.
5
-
-
Manufacturing, supplying and fixing retro reflective overhead informatory road signage and boards rectangular type, made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat complete all as specified and as directed.
5
-
-
Notes : The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specifications, and direction of the Engineer-in-Charge. Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment. The rate also shall be deemed to be inclusive of necessary foundation and frame work.
-
-
-
Manufacturing, supplying and fixing retro reflective cautionary/ warning sign boards of equilateral triangular shape having each side of 900mm with support length of 3650mm and made up of 2mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders, etc., as per IRC; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5mm to a vertical post made up to M.S.
3
-
-
Tee section ISMT 50x50x6mm welded with base plate of size 100x100x5mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge
Note : Rate quoted shall be deemed to be inclusive of necessary foundation and frame work.
-
-
-
Manufacturing, supplying and fixing retro reflective Mandatory/ Regulatory sign boards of 900mm diametre with support length of 3750mm and made up of 2mm thick luminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5mm to a vertical post made up to M.S.
3
-
-
Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge
Note : Rate quoted shall be deemed to be inclusive of necessary foundation and frame work.
-
-
-
SEWAGE DISPOSAL
-
-
-
Provision of coventional LLDPE Septic Tank for 25 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection, including necessary fittings & fixtures, etc., complete all as specified.
6
-
-
Construction of RCC Septic Tank for 100 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, Base slabs, Baffle walls and Roof Slab including beams, etc., with vent shaft, manhole openings with cover connection including necessary fittings & fixtures, etc., complete with effective depth of 1.50m and overall depth of 3m Conventional type all as shown in drawing No. TD/ST/795 Sheet Nos. 1/2 to 2/2 complete all as specified.
1
-
-
Construction of RCC Septic Tank for 50 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, Base slabs, Baffle walls and Roof Slab including beams etc with vent shaft, manhole openings with cover connection including necessary fittings & fixtures, etc., complete with effective depth of 1.50m and overall depth of 3m Conventional type all as shown in drawing No. TD/ST/796 Sheet No. 1/1 complete all as specified.
2
-
-
Construction of Soakage Wells of size 1.20m dia x 3.00m deep (effective depth), excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in m25/ SFRC cover, interconnecting pipes of RCC/ DWC complete filled with brick bats all as shown in drawing No. TD-563 Sheet No. 1/1 complete all as specified.
4
-
-
Construction of Soakage Wells of size 1.20m dia x 1.50m deep (effective depth), excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25, interconnecting pipes of RCC/ DWC complete filled with brick bats all as shown in drawing No. TD-563 Sheet No. 1/1 complete all as specified.
6
-
-
Construction of Soakage Wells of size 1.8m dia x 3.00m deep (effective depth) in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 concrete incl intercepting chamber made of brick masonry in CM RCC cover slab M-25 intercepting pipes of RCC/ DWC complete filled with brick bats all as shown in drawing No. TD-563 Sheet No. 1/1 complete all as specified.
8
-
-
SECURITY WALL/ COMPOUND WALL/ FENCING & GATE
-
-
-
M&L for PVC chain link fencing using MS angle, 50x6mm FI fillets, 10mm dia straining rod, etc., complete all as specified.
60
-
-
S&F concentrina coil of 610mm diameter punched tape (supporting on MS Angle iron frame and barbed wire all as specified and shown on drg) manufactured using central core of high tensile GI spring steel core wire of 2.6mm dia around which a tape of razer sharp blades (Low carbon GI Stripes) of thickness 0.52mm is machine crimped with following specifications :-
(a) Dia of coil (Unstretched) = 610mm
(b) No of Circles = 51 turns per coil
(c) Wt of each coil with hessian cloth = 8.50 kg +/- 0.5Kg
(d) Coverage per coil = 8Rm
(e) Dove tail clips shall be grade A as per IS:2062 & hot dip galvanised with 20microns or 290gms/sqm. 5 clips per 2 spiral turns approx 125 clips per coil.
(f) The tensile strength of spring steel core wire shall be 1620 N/Sqmm (min) all as per IS:4454 (Part I) with zinc coating of 230gm/Sqm as per IS:2629
(g) Punched tape shall be matt finish with average coating of galvanisation of 18 microns.
200
-
-
Note :
(i) MS angle iron frame and barbed wire shall be measured and paid separately.
(ii) The concentrina coils shall be tied to barbed wire with 1.2mm GI wire. (iii) Concentrina coil shall be measured along the length of the wall.
-
-
-
EXTERNAL WATER SUPPLY
-
-
-
M&L for cutting the existing 150mm DI pipe and inserting the TEE (150X150X100mm) including necessary threading, union, fittings, joints, etc., complete all as specified and directed.
2
-
-
M&L for cutting the existing 150mm DI pipe and inserting the TEE (150X150X80mm) including necessary threading, union, fittings, joints, etc., complete all as specified and directed.
2
-
-
M&L for cutting the existing 150mm CI pipe and inserting the TEE (150X150X50mm) including necessary threading, union, fittings, etc., complete all as specified and directed.
4
-
-
M&L for centrifugally cast (Spun) Ductile Iron pipe of size 100mm dia bore with socket & spigot end centrifugally, class K-7 conforming to IS: 8329:2000 marked with and including Rubber Gaskets used with Push-on-jointing confirming to IS:5382 in any length laid in trenches with and including all fittings all as specified.
200
-
-
M&L for construction of Valve Chamber 600 x 600 x 600mm depth with PCC 1:4:8 foundation, brick work in cement mortar 1:4 using class B bricks, PCC 1:2:4 coping at the top, plastering 15mm thick in CM 1:4 including MS sheet cover 3mm thick with angle iron frame 50x50x6mm, locking arrengement, etc., complete with painting on steel surface with one coat of red oxide paint over two coats of synthetic enameeled paint, necessary excavation and earth work all as specified and directed.
13
-
-
EXTERNAL ELECTRIC SUPPLY
-
-
-
Supply, installing, testing and commissioning, of 160KVA Unipack Compact Sub-Station (CSS) with non extensible RMU 11kV, consisting of the following :
1
-
-
(A) HT SWITCHGEAR : 11kV 630Amps 21KA for 3 Sec. SF6 insulated Non-Extensible Compact switchgear (Type CV) consisting of 1 No. Fixed Motorized Loadbreak switch with associated earthswitch for incoming cable and 1 No. Fixed Motorized Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure, with series trip,self powered microprocessor based numerical over current relay (IDMTL + Inst.) protection along with . Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm Al. unarmorured XLPE Cable. (Make: ABB) - 1 No
Self powered non-communicable O/C & E/F Protection Relay of Ashida Make - ADR141A (50,50N,51,51N) - 1 No
CT of Ratio - 40/1A, CL - 5P10, Burden - 2.5VA for Protection - 1Set
Voltage Presence Indications for Incoming Healthy Indication - 2Set
Fault Passage Indiactor with accessories in LBS - 1No
Mechanical ON/OFF Indication - 1No
Manometer - 1No
Operating Handle - 1No
Battery/Battery charger - 12 V DC, 12AH - 1No
-
-
-
(B) TRANSFORMER (IS:1180 (Level - iii) amended update) :
160KVA 11KV/433V DYn11 Cast Resin Copper Wound ONAN Type Transformer with Off load tap links of range +5% to - 5% @2.5% steps. Losses ( As per IS Tol ) NLL-950W and FLL - 3600W, Impedance : 4.5% (With IS Tol.), Class of Insulation - F. Temperature Rise in winding over ambient temp. of 50Deg C - shall be 90 Deg. C. ( Make- Ames Ipex/Eq) - 1No
WTI Scanner with Alarm & Triping Contact - 1No
Surge Arrestor - 1No
(C) LVS PANEL 400AMPS Aluminium BUSBAR (100% FOR PHASE AND 50% FOR NEUTRAL), Current Density - 1 Amp/sqmm
-
-
-
INCOMER FROM TRANSFORMER :
360Amps 433V 36KA 4P Fixed Manual Type Molded Case (MCCB) Circuit Breaker with Mircoprocessor based released overcurrent, short circuit fault protection (Make: ABB) - 1No
RYB, ON-OFF Indications - 1Set
Digital Multifunction Meter of Class 1.0 accuracy with RS485 Port ( Make: Secure/ ABB/ Rishabh/Eq) - 1No
Metering CT : 400/5A, 5VA, Class 1.0 Accuracy ( Make : G&M/Newtek/Eq) - 1Set
320A 433V 25KA 4P Fixed Manual Type Molded Case (MCCB) Circuit Breaker with Mircoprocessor based released overcurrent, short circuit fault protection (Make: ABB) -1Nos
160A 433V 25KA 4P Fixed Manual Type Molded Case (MCCB) Circuit Breaker with Mircoprocessor based released overcurrent, short circuit fault protection (Make: ABB) - 2Nos
100A 433V 25KA 4P Fixed Manual Type Molded Case (MCCB) Circuit Breaker with Mircoprocessor based released overcurrent, short circuit fault protection (Make: ABB) - 1No
(D) APFC Panel with 50KVAR - 1Set
(E) OUTDOOR ENCLOSURE : Outdoor type enclosure having construction of Galvanised Sheet Steel of thickness 1.5/2mm with 4mm Baseframe. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder coated ( colour Light Gray & D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Seperate switch operated bulket lamp + Hooter shall be provided in Transformer - 1Set
-
-
-
(F) INTERCONNECTION & EARTHING :
Interconnection Between HT switchgear & Transformer using 1C x 3R x 95 Sq.mm XLPE Single core Aluminum cable & Interconnection between Transformer & LT switchgear using Aluminium Busbars. Internal Earthing connections by using 50x6 mm GI Strips including Transformer Neutral - 1Set
Note : The cost of PCC outdoor plinth, Erection , Unloading and Civil work for package substation including Commissiong, site testing ( factory & SEI) shall be deemed to be included in the quoted rate.
-
-
-
Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 400 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangementS (including provn of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm complete all as specified and directed. Panel should be above ground level. The scope of work includes the following:-
1
-
-
(a) Incoming :
(i) MCCB 250 Amps, 4 pole 415 Volts AC 25 KA rupturing capacity - 01 No.
(ii) Digital Voltmeter 0-500 Volts square type flush pattern with 3 way selector rotary switch - 01 No
(iii) Digital Ammeter with CT Ratio 400:5 square type with 3 way selector rotary switch -01 No
(iv) Indicator LED type RYB set - 01 No ( Three each)
(b) Outgoing :
(i) MCCB 4 pole 100 Amp 16KA -02 No
(ii) MCCB 4 pole 63 Amp 16 KA -04 No
(iii) MCB TPN 40 Amps rating -04 No (iv) MCB SPN 32 Amps rating -01 No (v) Digital time switch including suitable power contactor for street light
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15cm thick in foundation,brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45cm above the nearest road level.
Note : All out going feeders shall be connected by cable through suitable size gland plate/ glands.
-
-
-
Supply, installing, testing and commissioning, factory made and tested LT feeder pillar box (KIOSK), (CPRI type test certified), outdoor type, platform mounted, suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 200 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangements (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm complete all as specified and directed. Panel should be above ground level. The scope of work includes the following :-
1
-
-
(a) Incoming :
(i) MCCB 4 pole 415 volts AC grade 100 Amp and 16 KA rupturing capacity -01 No.
(ii) Digital volt meter 0-500 volts square type flush pattern with 3 way selector rotary switch - 01 No
(iii) Digital ammeter with CT Ratio 400:5 square type with 3 way selector rotary switch -01 No
(iv) Indicator LED type RYB set - 01 No ( Three each)
(b) Outgoing :
(i) MCB TPN 40 Amps rating -04 No (ii) MCB SPN 32 Amps rating -01 No (iii) Digital time switch including suitable power contactor for street light
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15cm thick in foundation,brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts, etc., for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Note : All out going feeders shall be connected by cable through suitable size gland plate/ glands.
-
-
-
Supply, installing, testing and commissioning, factory made and tested LT feeder pillar box (KIOSK) (CPRI type test certified), outdoor type, platform mounted, suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 200Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish , front opening type, with aprons for cable entry, with double door shutter and locking arrangements (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm complete all as specified and directed. Panel should be above ground level. The scope of work includes the following :-
1
-
-
(a) Incoming :
(i) MCCB 4 pole 415 volts AC grade 125 Amp and 16 KA rupturing capacity -01 No.
(ii) Digital volt meter 0-500 volts square type flush pattern with 3 way selector rotary switch -01 No
(iii) Digital ammeter with CT Ratio 400:5 square type with 3 way selector rotary switch - 01 No
(iv) Indicator LED type RYB set - 01 No ( Three each)
(b) Outgoing :
(i) MCCB 4 pole 100 Amp 16 KA - 01 No
(ii) MCB TPN 40 Amps rating - 02 Nos (iii) MCB SPN 32 Amps rating - 01 No (c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15cm thick in foundation,brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts, etc., for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Note : All out going feeders shall be connected by cable through suitable size gland plate/ glands.
-
-
-
Supply, installing, testing and commissioning, factory made and tested LT feeder pillar box (KIOSK), (CPRI type test certified), outdoor type, platform mounted, suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 400 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front opening type, with aprons for cable entry, with double door shutter and locking arrangementS (including provn of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm complete all as specified and directed. Panel should be above ground level. The scope of work includes the following:-
1
-
-
(a) Incoming :
(i) MCCB 4 pole 415 volts, AC Grade, 250 Amp, 36 KA rupturing capacity -01 No.
(ii) Digital volt meter 0-500 volts square type flush pattern with 3 way selector rotary switch -01 No
(iii) Digital ammeter with CT Ratio 200:5 square type with 3 way selector rotary switch -01 No
(iv) Indicator LED type RYB set - 01 No ( Three each)
(b) Outgoing :
(i) MCCB 3 pole 415 Volts grade 100 Amp and 25KA rupturing capacity -04 Nos
(ii) MCCB 3 pole 415 Volts grade 63 Amp and 25KA rupturing capacity -04 Nos
(iii) Timer clock,relay,conntrolar assy MCB TPN 63 Amp with suitable contactor. (iv) MCB TPN 32A 415V-02 NosMCB SPN 32 Amps rating -01 No (v) MCB SPN-16 A-10 Nos
(c) Plateform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone,15cm thick in foundation, brick work in cm 1:6 with sub class 'B', old size bricks, rendering 15mm in cm 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C1 using 20mm graded crushed stone aggregrate on top and grouting bolts etc for panels. The plateform shall be such that it is off a height 45 cm above the nearest road level.
Note: All outgoing feeders shall be connected by cables through suitable size gland, plate / glands.
-
-
-
S&F cable route indicator made of 15 x 15 x 6mm thick MS plate welded with 10mm x 30cm long MS rod grouted in PCC block of size 0.2 x 0.2 x 0.3m and writing LT cable complete all as specified and as directed.
60
-
-
S&F FRP pole box of size 168 x 253 x 115mm, thermoplastic, polycabonate, IP-66 complete with 4 pole 32 A connector, Double compression glands-2 Nos, MCB SP 6 Amps mounted with GI clamps of suitable size with nuts and bolts on street light pole all as specified and as directed.
16
-
-
Material and labour for street light bracket made of 40mm GI pipe light grade 1.5m length bent in shape for mounting street light on one end, fixing the bracket on pole with suitable GI clamps, Nus and bolts all as specified and as directed.
38
-
-
S&F SMC terminal box of size 230 x 170 x 105mm (internal diamensions) made of impact resistance plastic & heat resistant materials including MCB SP 6A with DIN bar and 4 way terminal block, and fixing the box to street light pole made of 25x 3mm flat iron with clamps, nuts and bolts complete all as specified and directed.
22
-
-
S&F MCCB 4 pole 63 Amps, 415 Volts, 50 Hz, with breaking capacity 25 KA incl addition/ alteration in existing panel to fix MCCB and making incliing and outgoing connections complete all as specified and directed.
2
-
-
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised Iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer, etc., of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 5 of SSR Part I and connection to earth test point including testing on completion all as specified and as directed.
34
-
-
Note : The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
-
-
-
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the main earth lead Galvanised Iron wire 4mm dia, by means of nuts, bolts, check nuts and washer, etc., of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 5 of SSR Part I and connection to earth test point including testing on completion all as specified and as directed.
2
-
-
Note : The cost of 7.5m long galvanised iron earth wire 4mm dia and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
-
-
-
M&L for filling with riddle earth in trenches including watering and consolidation, spreading, levelling, punning for laying/ cushioning of cable complete all as specified and as directed. Note: Punning thickness shall be measured and paid.
472
-
-
COOLING APPLAINCES
-
-
-
S&F refrigerator, electric driven (single phase) BEE 5 star rated of capacity 195 litres complete all as specified.
2
-
-
S&F refrigerator, electric driven (single phase) BEE rated double door of capacity 310 litres complete all as specified.
2
-
-
S&F Voltage stabilizer of capacity 1 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170Volts to 280Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and surge protection complete all as specified and directed.
8
-
-
S&F Voltage stabilizer of capacity 2 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170Volts to 280Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and surge protection complete all as soecified and as directed.
6
-
-
S&F Voltage stabilizer of capacity 4 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170Volts to 280Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and surge protection complete all as specified and directed .
20
-
-
S&F Voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170Volts to 280Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and surge protection complete all as specified and directed .
18
-
-
MACHANICAL LAUNDRY
-
-
-
Supply, Installation, Testing and Commissioning of the Mechanical Laundry equipments and associated sub-systems including piping work & necessory fabrication in dryning & ironing room, all as specifed, as per latest standard engineering practices and as directed. It shall be suitable for linen like uniform, room furnishing, personal garments, Bed sheets & Pillow Covers, etc,. complete all as specified here-under :-
2
-
-
(A) 02 Nos Heavy duty Washer Extractor with the following features :-
(i) Capactiy - 45 Kg or next higher capacity commercially available;
(ii) Inbuilt electrical heating coil capacity - not less than 22.5 KW; (iii) Motor capacity - not less than 7.5 HP;
(iv) Drum Volume - not less than 450 Ltr;
(v) Machine shall be heavy duty, front loading & unloading, High Spin 600RPM or more with Auto reverse & forward rotation; full programmable for washing cycles and shall have a feature of pause and continue the same balance cycle on power failure. (vi) Material of construction: the outer body - SS 304/ powder coated MS sheet; inner and outer Basket/drum - Stainless Steel 304.
(vii) Display: Microprocessor/ PLC based front display complete with water level indicator, temperature, function & timer in digital format.
(viii) Control: Microprocessor/ PLC based control, Variable frequency drive
(ix) Door: Front door shall have toughened glass window; manual and auto door closing mechanism sothat It shall remain closed during operation;
(x) Additional features : It shall take the solvent/chemical as and when required automatically from 4-5 dispensors, It shall be Self-lubricating, Soft Mount, Suspended, Self-aligned machine; Emergency stop button & Safety limit switches.
(B) 02 Nos of Tumber Dryer with the following features :- (i) Capactiy - not less than 60 Kg;
(ii) Inbuilt electrical heating coil capacity - not less than 27KW;
(iii) Drive Motor/Exhaust motor capacity - not less than 2 HP Each;
(iv) Basket Volume - not less than 1227 Ltr capacity;
(v) Machine shall be heavy duty, front loading & unloading, full programmable for drying cycles and shall have a feature of pause and continue the same balance cyle on power failure.
-
-
-
The drier shall be Automatic-cooling, Auto-timed, Auto forward&reversible rotation, Auto digital temperature control.
(vi) Material of construction: the outer body - SS 304/ powder coated MS sheet; inner and outer Basket/drum - Stainless Steel 304.
(vii) Display: Microprocessor/ PLC based front display complete with water level indicator, temperature, function & timer in digital format.
(viii) Control: Microprocessor/ PLC based control, Variable frequency drive for dual motors; (ix) Door: Front door shall have toughened glass window; manual and auto door closing mechanism sothat It shall remain closed during operation;
(x) Suction Blower - Heavy duty Centrifugal Suction Blower and dynamically balanced;
(xi) Insulation - Rockwool/Glass wool duly packed on all sides & front of the drier to minimize the heat loss & saves energy;
(xii) Lint Screen - Self cleaning lint screen of SS-304. Facility of cleaning should be through front door.
(xiii) Additional features: It shall be Self-lubricating, Soft Mount, Suspended, Self-aligned machine; Emergency stop button & Safety limit switches; Spray Nozzle to inject chemical/ softener.
(C) 02 Nos vacuum ironing table with the following features :- (i) Table Top Size -1300mm X 800mm with Adjustable height; (ii) Table top - SS/GI/MS powder coated sheet of suitable thickness padding with heat resistant material like Silicon foam and heat proof cloth etc.; Perforated flat top padded with high porosity;
(iii) Main Body - Made of SS/GI/MS powder coated sheet/plates
-
-
-
(iv) Blower - Heavy duty Powerful suction through Centrifugal blower of minimum 0.5HP Motor activated by spring loaded full length foot pedal working in combination with heavy duty micro switch
(v) Heater - In-built Thermostatically controlled stainless steel heater;
(vi) Electric Steam- Die cast sole plate, Teflon shoe and thermostatically controlled; Iron heating element with moisture trap, Rubberized handle;
(vii) Accessories like trays, side iron stand etc standand suction and chimney complete and connecting up to the steam pipe. (D) 02 Nos Flat bed press table with the following features:- (i) Steam heated, Auto-timed, Auto-temperature controlled, Double Switch operation, Built-in Suction Blower, Pneumatically controlled;
(ii) Head & Bed - Polished Stainless steel/High quality steel with Teflon coated/Nickel plated; Head & Bed Size - Minimum 11380X700mm; (iii) Main Body- Made of Mild Steel sheets of 1.5 mm thickness, Welded structure and finished with powder coating
(iv) Blower - Heavy duty Suction Blower with powerful suction
(v) Safety - Emergency Stop of the machine with emergency switch. Automatic stopping of the machine for Finger guard for operator safety;
(vi) Control - Push Button for raising and lowering of the head pneumatically;
(vii) Temperature- Digital temperature controller
(viii) Suction and chimney complete and connecting up to the steam pipe.
(E) 01 Nos fully automatic Electrical Staem Generator for continous ironing with the following features :- (i) Automatic Electrical Staem Generator shall be compact & poratable in size; It shall produce almost 100% dry steam;
-
-
-
Suitable to with-stand at high operating pressure(3-4bar); with error detection, auto cut-off, Microprocessor/ PLC based with high temperature cut-off. One touch operational panel; (ii) Automatic safety feature in case of pressure exceeding the set pressure to cut off the steam generation; min 5-7 standard safety mechanisms with alarm system., (iii) Detachable SS Heating element - Capacity of heating coil 6 KW minimum, protected by thermostats and water level controller;
(iv) Steam output - 10 Kg / hr minimum;
(v) Operating Pressure - 3.5 Bar approx.;
(vi) Suitable for No. of tables - 2 Nos
(vii) Grade - Non-IBR Grade;
(viii) The Steam Generator shall be provided with feed water tank of suitable capacity, high pressure pump and water softner plant.The softner plant shall have the capacity to bring down the hardness up to 5 ppm.
(F) Air Compressor with the following features :-
(i) The air compressor of Kirloskar/Elgi/Ingersolrand make shall be multistage stage, fully
automatic suitable for delivering dry compressed air at pressure compatible to Ironer.
(ii) Drive - Belt driven with pulleys, belts and belt guard.
(iii) Motor - 2-3 HP capacity (Kirloskar/Siemens/NGEF/Crompton Greaves make)
(G) Water, Steam and Air Piping work incuding all fittings including valves, tees, elbows, reducers, union, flanges, rubber gaskets, washer etc. as required for making all the laundary equipments fully functional is to be done as follows :-
(i) Water pipes & fittings - GI Medium grade, sizes as required;
-
-
-
(ii) Steam pipes & fittings - Seamless MS pipes conforming to SA106 Gr.B (Sch 40 rating), sizes as required; Steam pressure reducing valves, Steam trap assembly consisting of steam stop valves, disc check valves,strainers etc.
(iii) Drain Piping & fittings - for hot drain water/steam from laundry equipments, Seamless MS pipes conforming to SA106 Gr.B (Sch 40 rating), sizes as required;
(iv) Air pipes & fittings - GI Heavy grade, sizes as required;
(H) All the cabling work from the dedicated LT Panel to various laundry equipments including control wiring(if any) shall be carried out with proper size cables and wires. All the cables&wires shall be routed through perforated GI cable trays of suitable sizes made out of minimum 1.5 mm sheet metal. The cables and wires shall be neatly fastened in trays with clamps. Cable trays shall be properly routed, secured and supported from roof/wall using GI angle irons, fastener etc. in such a ways that it does not cause any obstruction for free movment of manpower and laundry trollies in the Drying and Ironing room. Cable termination box/Panel with suitable rating MCB/MCCB and R-Y-B LED indication shall be provided near each laundry equipment for easy connection of equipment and control.
(J) All necessory civil work including foundation and grouting arrangment for various laundry equipments as per OEM requirement and it's cost is deemed to be included in quoted rates.
(K) Lay out of all the Laundry equipments; Panels; cabling, piping and ducting work inside the Dryning and Ironing Room shall be got approved by the contractor from the GE before construction of the Room. Requirment of any floor duct, routing of pipes/cables under floor, if any, shall be considered while finaling the layout and it's cost is deemed to be included in quoted rates.
(L) One number of WASH ROOM TROLLEY -The washroom trolley shall be fabricated out of Stainless Steel tubes and flats in all welded construction ground smooth & finished, supported on swiveling wheels. Capacity -50kg
-
-
-
(M) One number of SHELF TROLLEY (for Finished linen) The linen trolley shall be of SS, with SS tubes, bars, and foldable front, fitted with at least 4 Nos. SS shelves (with 2-shelves removable), base frame shall be supported on swiveling wheels. Capacity 70 Kg
(N) One number of MOBILE TABLE - Folding table designed for carrying rolling and folding of linen in the laundry with MS frame and 01 bottom shelf for storage, Complete with heavy-duty ball bearing for swiveling wheels, of polished Stainless steel. Table top size 1200mm x 750mm
(O) One number of SHELF FOR FINISHED GOODS With 4 shelves; Made of Mild Steel, Finished with Stoving paints; Size- 1200mmx460mmx180mm
Make of Laundry Equipments: IFB-Ramsons, STEFAB, Lucky Engineering, Bucato
-
-
-
M&L for installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system with powder costed finish, front opening type .The panel shall be dust,weather and vermin proof, IP 65 class protection and made of CRCA MS sheet 2.0 mm thick for outer shell and 2 mm thick for inner shell having TPN Aluminium bus bars of rating 300 A supported on SMC insulators , bottom base channel of MS section not less than 100 mmx 50 mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 nos earth stud, solid connections from main bus bar to switch gears with required size of copper bus bars and control wiring with min 1.5 sqmm PVC insulated copper conductor cable. The panel shall be mounted on suitable PCC foundation.
(a)Incoming: i) MCCB 4 pole 415 volts AC grade 200 Amp and 25 KA rupturing capacity -01 No.
(ii) Digital volt meter 0-500 volts square type with 3 way selector rotary switch -01 No
2
-
-
(iii) Digital ammeter with CT Ratio 100:5 square type with 3 way selector rotary switch -01 No
(iv) CTs of rato 100:5 ISI marked - 1 Set (Three each)
(v) Indicator LED type RYB set - 01 Set ( Three each) (b) Outgoing:
(i) MCCB 4 pole 415 volts grade 63 A, 25 KA rupturing capacity - 06 Nos (ii) MCB, SPN, 415 volts grade, 20 A, 10 KA rupturing capacity - 01 Nos Note : All out going feeders shall be connected by cable through suitable size gland plate / glands.
-
-
-
S&F 5000 ltrs capacity PVC stoarge water tank, hoisted and fixed in position, double layered and making necessary inlet and outlet connections complete all as specified and as directed.
2
-
-
DISMANTLING/ DEMOLITION
-
-
-
Dismantling any type of Aluminium joinery works like doors, windows, ventilators, partitions etc including all accessories and fixtures complete all as specified and directed.
10
-
-
Dismantling sub main wiring 3 runs 4 sqmm copper conductor including PVC conduit/ Casing & Capping complete.
550
-
-
Dismantling and taking down unserviceable DBs, MCBs.
18
-
-
Dismantling unserviceable LT UG Cable of sizes upto 4 core x 16 Sq mm.
530
-
-
Dismantling unserviceable LT UG Cable of sizes upto 2 core x 16 Sq mm.
120
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%