Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 93,840Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690196_1Tender No
8434/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and fixing mild steel rag bolt or lewis bolt, screwed one end with hexagonal or square nut and washers, other end enlarged and jagged or lewised, exceeding 15cm but not exc 30cm long, 12mm dia neck complete all as specified and as directed.
225
-
-
... More
Supply and fix powder coated aluminium frame for windows, doors & ventilators with one or more rebates including joining cleats for fixing etc. complete all as specified and as directed
35
-
-
... More
Supply and fix powder coated aluminium window and ventilators shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no), hinges type B-21 100mm long (2 no) suitable handle (1 no) complete all as specified and as directed. Note: Glass panel and wire mesh shall be measured and paid separately.
12
-
-
... More
Supply and fix Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) grade Fe-290(Gde E-165) complete all as specified and as directed.
1050
-
-
... More
Supply and fix hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 with bracing aluminium mesh to lower skeleton complete all as specified and as directed.
1000
-
-
... More
Material and labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
250
-
-
... More
Demolition of cement concrete, unreinforced, in ground floor and paving not exceeding 15cm thickness above or below ground level complete all as specified and as directed.
47.5
-
-
... More
Material and labour for plain cement concrete 1:2:4 type B2 using 40 mm graded stone aggregate in foundations, filling and mass-concrete complete all as specified and as directed
5.5
-
-
... More
Supply and fixing 2mm dia galvanised steel chicken wire mesh complete all as specified and as directed.
100
-
-
... More
Material and labour for 25mm thick plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate complete all as speciifed and as directed.
225
-
-
... More
Material and labour for 15mm thick rendering in cement mortar 1:4, on fair faces of brick work/ concrete surfaces using water proofing compound @3% by weight of cement finished even and smooth without using extra cement complete all as specified and as directed.
Note: Water proofing compound shall be measured separately.
250
-
-
... More
Supply only liquid water proofing compound.
20
-
-
... More
Material and labour for RCC design mix M-30 in foundaions including rafts, footings, foundaion beams, plinth beams, bases for columns etc, basement slabs and mass concrete all as specified and as directed.
17
-
-
... More
Use and waste of formwork to sides of concrete foundation, etc, rough finished surfaces of concrete all as specified and as directed.
120
-
-
... More
Material and labour for TMT bars, 10mm dia and over cut to length bent to shape required including cranking, bending, spirally hooping for columns hooking ends and binding with mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed.
820
-
-
... More
Material and labour for TMT bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length bent to shape required including cranking, bending, spirally hooping for columns hooking ends and binding with mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed.
700
-
-
... More
Material and labour for applying 3 coats of white wash to newly plaster surfaces including preparation of new wall surfaces complete all as specified and as directed.
250
-
-
... More
Taking down cement plaster on brick or stone masonry surfaces etc including racking out joints hacking for keys, scrubbing down wth water etc. complete all as specified and as directed.
98
-
-
... More
Material and labour for 15mm thick rendering in cement mortar 1:4, on fair faces of brick work/concrete surfaces, finished even and smooth without using extra cement all as specified and as directed.
38
-
-
... More
Material and labour for 10mm thick rendering in cement mortar 1:6, on fair faces of brick work/concrete surfaces, finished even and smooth without using extra cement all as specified and as directed.
30
-
-
... More
Material and labour for 5 mm thick rendering on concrete ceiling surfaces in CM 1:3, finished even and smooth without using extra cement all as specified and as directed.
30
-
-
... More
Material and labour for applying 3 coats of white wash to newly plaster surfaces including preparation of ceiling surfaces complete all as specified and as directed.
30
-
-
... More
Material and labour for preparation of new plastered surfaces of wall and and applying two coats of apex ultima/anti fungal exterior paint of required shade @ 1.67 litre/10 Sqm over a coat of exterior primer applied @ 2.20 kg/10 Sqm over a coat of external wall care putty not exceeding 1mm thick complete all as specified and as directed.
38
-
-
... More
Material and labour for preparing newly plastered wall surfaces and applying two coats of acrylic washable distember paint over a coat of primer through authorised company applicator using modern tools and spray technique complete all as specified and as directed.
30
-
-
... More
Material and labour for complete removal of existing treatment by mechanical jet spray /grinder and applying two coats of acrylic washable distember paint over a coat of primer through authorised company applicator using modern tools and spray technique complete all as specified and as directed.
120
-
-
... More
Material and labour for complete removal of existing treatment by mechanical jet spray /grinder and applying two coats of apex ultima/anti fungal exterior paint of required shade @ 1.67 litre/10 Sqm over a coat of exterior primer applied @ 2.20 kg/10 Sqm over a coat of external wall care putty not exceeding 1mm thick complete all as specified and as directed.
170
-
-
... More
Taking down chowkats or frames with shutters not exc 1.5 Sqm each without taking off shutter from the frame & removed to store complete all as specified and as directed.
4
-
-
... More
Taking down chowkats or frames with shutters exc 1.5 Sqm and n. exc 4 Sqm each without taking off shutter from the frame & removed to store complete all as specified and as directed.
1
-
-
... More
Supply and fix powder coated aluminium door shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no), hinges type B-21 100mm long (2 no) suitable handle (1 no) complete all as specified and as directed.
2.5
-
-
... More
Material and labour for veneered decorative plywood, 9mm thick plywood, grade 1 with BWR resin, with decorative face veneers on both faces, fixed with screws to timber frame work complete all as specified and as directed.
1
-
-
... More
Supply and fix powder coated deco grill of make DG-104 of size (10 x 5.2mm) along with its frame complete all as specified and as directed.
4
-
-
... More
Supply and fixing 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed
8
-
-
... More
Supply and fixing 100mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed
10
-
-
... More
Supply and fix glass panels of sheet glass 4 mm thick ordinary quality and glazing with oil putty not exceeding 0.5 sqm in each pane complete all as specified and as directed.
4
-
-
... More
Supply and fix aluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
4
-
-
... More
Material and labour for 75mm thick plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection/pavement complete all as specified and as directed.
30
-
-
... More
Material and labour for calibrated prepolished kota stone slab 20-25mm thick as in flooring including 20mm thick cement screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Note: Final cutting shall be done at site and surface finished with bee-wax polish.
65
-
-
... More
Supply and fixing mild steel plain plates (plain or chequred), square, cut or notched (ordinary or counter sunk) including forming holes, without any attachment of any size for making cover for valve pits including nuts, bolts, washers, welding ,bending cold or hot drilling holes for bolts, in any shape of size as indicated or directed conforming to Fe 410-W(Gde-E-250) quality 'A' including taking out old petted corroded plates complete all as specified and as directed
350
-
-
... More
Supply and fix roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing using mild steel section of Fe-410W Gde-E-250 quality A, beam, tee, angles, channels or flat sections including distance pieces, cleats etc complete all as specified and as directed.
200
-
-
... More
Material and labour for 15mm thick bedding layer or screed in cement mortar 1:3, on fair faces of brick work/concrete surfaces using water proofing compound finished even and smooth without using extra cement complete all as specified and as directed.
Note: Water proofing compound shall be measured separately.
70
-
-
... More
Supply only liquid water proofing compound.
2
-
-
... More
Material & labour for seven course water proofing treatment over RCC slab by applying oil based bitumen primer @0.20 Kg/Sqm, providing and laying 4 mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with one woven polyester mat weighing not less 160g/Sqm having softening point not less than 140 degree centigrade longitudinal tensile strength not less than 650 N/5 cm, tearing strength of 180 N/torch application including minimum 10 cm side over lap & 15 cm end overlap, applying a coat of blown grade hot bitumen 90/15 over membrance @ 1.2 Kg/Sqm and applying solar reflective/ bituminous aluminium paint @ 100 gm/Sqm complete all as specified and as directed by Engr-in-Charge.
80
-
-
... More
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs etc. also splays between floors and beams, etc. complete all as specified and as directed.
30
-
-
... More
Material and labour for TMT bars, 6 mm to 8 mm dia cut to length bent to shape required including cranking, bending, spirally hooping for columns hooking ends and binding with mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed.
10
-
-
... More
Material and labour for RCC nominal mix 1:2:4, type B0 using 12.5mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
0.5
-
-
... More
Removing concrete all around reinforcement including from behind the reinforcement bars to given an average 25mm but not less than 15mm clear air gap by manual methods such as hammering the rebar using wire brushes, chiseling etc and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry to give it a totally rust free finished steel surfaces complete all as per manufacturers instructions and as directed by Engr-in-charge. Make: STP/Fosroc/Sika/DR fixit or equivalent as listed in approved makes
20
-
-
... More
Providing & applying single coat of epoxy bond adhesive with minimum compressive strength of 40N/Sqmm on prepared non metallic existing surfaces with brush complete all as per manufacturers instructions and as directed by Engr-in-charge. Make: STP/Fosroc/Sika/DR fixit or equivalent as listed in approved makes
20
-
-
... More
Providing & applying epoxy zinc rich primer having minimum specific gravity 1.75, minimum wet film thickness/coat 40 microns, minimum adhesive bond strength with steel of 1.5N/Sqmm on prepared steel surfaces with brush complete all as per manufacturers instructions and as directed by Engr-in-charge. Make: STP/Fosroc/Sika/DR fixit or equivalent as listed in approved makes
20
-
-
... More
Supplying, mixing and applying two component structural grade polymer modified reinstatement mortar where local spalling has taken place or shuttering is not possible as in roof facia, parapet, chajjah, ceiling etc. The mortar can applied in layers not exceeding 6mm thick in each layers and upto 25mm thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have minimum compressive strength of 12N/Sqmm in one day and 45N/Sqmm in 28 days. A modified styrene vutadience emulsion for use as a bonding agent and guaging liquid for cementious system to be mixed with cement slurry before the application of micro concrete to be used at 6 litre/bag of cement. The bonding agent should have minimum comppressive strength of 24 N/Sqmm. Minimum tensile strength 3.5N/Sqmm, minmum flexural strength 6.5N/Sqmm complete all as per manufactures instruction and as diretced by Engr-in-charge. Make: STP/Fosroc/Sika/DR fixit or equivalent as listed in approved makes
Note: (i) Both the components are to be mixed as per manufactures instruction and 3 to 5% of water to be added to make brushable consistency
(ii)The second coat needs to be applied only after drying of the previous coat. First coat & second coat shall be applied in a perpendicular direction
(iii) All works shall be done as per specification.
(iv) All works shall be done after surface prepration including scaffolding.
20
-
-
... More
Taking down Copper /aluminium point wiring (light, fan, socket, bell, power point) complete fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting any type, building security light removing materials to store for keeping in safe custody for taking credit and making good the disturbed surfaces complete all as specified and directed.
13
-
-
... More
Material & labour for point wiring using approved colour coding as per IS, Red, Black and Green for single phase circuits with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade ISI-694 marked with valid CML No. single core multistranded cable in and including medium grade concealed PVC conduit not less than 20mm dia and accessories ISI marked with valid CML No IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories and with suitable size cast iron switch boxes for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire complete all as specified and as directed.
-
-
-
... More
One light point controlled by one switch
6
-
-
... More
One ceiling/exhaust fan point controlled by one switch and regulator
3
-
-
... More
One 5 pin 5/6 Amp socket outlet point controlled by one switch on the same board
2
-
-
... More
One 5 pin 5/6 Amp socket outlet point controlled by one switch on the independent board
2
-
-
... More
Material & labour for point wiring using approved colour coding as per IS, Red, Black and Green for single phase circuits with 2.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade ISI-694 marked with valid CML No. single core multistranded cable in and including medium grade concealed PVC conduit not less than 20mm dia and accessories ISI marked with valid CML No IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories and with suitable size cast iron switch boxes for fixing of switches sockets and fan regulators etc. including 2.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire for 6 pin 16A socket outlet on independent board including taking down old point wiring complete all as specified and as directed.
2
-
-
... More
Supply & fix in replacement ceiling rose surface bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed
9
-
-
... More
Supply & fix in replacement switch modular, 5/6 Amps, SP, 230 volts, one way complete all as specified and as directed.
9
-
-
... More
Supply & fix in replacement modular socket outlet 6A - 2/3 pin combined 2 modules complete all as specified and as directed.
4
-
-
... More
Supply & fix in replacement modular socket outlet 16A - 2/3 pin combined 2 modules complete all as specified and as directed.
2
-
-
... More
Supply & fix in replacement switch modular, 16 Amps, SP, 230 volts, one way complete all as specified and as directed.
2
-
-
... More
Supply & fix in replacement regal batten for LED tube lights, both side connection type and with ISI marked, medium grade LED tube rod 1 x 20 Watt, both side connection complete all as specified and as directed.
6
-
-
... More
Supply and fix exhaust fan heavy duty 300mm sweep 230 volts Ac 50 Hz 1400rpm, with high efficient heavy duty mortor and die cast aluminium mortor mounted on two ball bearings, aero dynamically countered blades, rigid frames with rubber mountings etc for silent operation, including connecting up from ceiling rose including taking down old u/s exhaust fan completed all as specified and directed.
3
-
-
... More
Supply and fix in replacement MCB distribution board in sheet metal enclosure, powder coated, factory made, IP 43 protection, double door type SPN 8 way with 200 Amps, 240 Volt rated bus bar neutral and earth connected bars using suitable required fixing arrangement complete all as specified and as directed.
3
-
-
... More
Supply and fix in replacement MCB SPN 32 Amps, 240 Volts, 10 KA 'C' series with all incoming/ outgoing connections with proper size of lugs complete all as specified and as directed.
3
-
-
... More
Supply and fix in replacement MCB SP 5 to 32 Amps, 240 Volts, 10 KA 'C' series with all incoming/ outgoing connections with proper size of lugs complete all as specified and as directed.
18
-
-
... More
Material and labour in replacement of sub main wiring with 2 runs of 4 Sqmm single core, PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed PVC conduit pipe of medium duty not less than 25 mm dia including necessary PVC conduit specials and one run of 4 Sqmm cable single core PVC insulated, unsheathed, 1100 Volts grade multistranded copper conductor FRLS cable as earth continuity conductor and connecting with suitable size thimble including cutting the chases etc and making good the disturbed surface to match with the existing complete all as specified and as directed. Note:-Two runs of 4 Sqmm size PVC copper cable, one run of 4 Sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
40
-
-
... More
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below ground level connected with galvanised strip of size 25 x 4 mm by means of nuts, bolts, check nuts and washers including welding of each joints made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore medium grade and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe light grade, wire mesh, charcoal or coke and common salt in alternate layer of 150mm compacted thickness all round the earth electrode, concrete earth pit in PCC 1:3:6 type C-1 with 20mm graded stone aggregate, 50mm thick precast RCC 1:2:4 cover slab re-inforced with 8mm dia TMT bar @ 150mm C/C both ways and suitable handle made of 10mm dia including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 metre etc all as shown on electrical plate No.3 of MES Schedule Part-I 2009 including testing on completion and taking down old earthing complete all as specified and as directed by Engr-in-charge
1
-
-
... More
Materials and labour in replacement of building security light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection of 45 Watt including suitable GI bracket of 25 mm dia and fixing arrangement on walls complete all as specified and as directed.
6
-
-
... More
Supply and laying in replacement XLPE, insulated, screened, PVC bedded, galvanised steel strip or wire, armoured, electric power cable, heavy duty, with stranded aluminium conductor 1100 Volts grade of size 6 Sqmm 2 core passing through pipes/ along wall/ roof/ across drain complete all as specified and as directed
50
-
-
... More
Supply and fixing PVC Junction box, with 2 x Aluminium busbar and one MCB SP 6 Amps for controlling street/ security lights water tight including taking down existing UNSV PVC junction boxes carefully of any capacity any type and removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed by Engr-in-Charge.
6
-
-
... More
Supply and fixing street light control panel, single phase 6 KW load with 24 hour digital timer, contactor rating 32 Amps TP, MCB rating 40 Amps, SPN including taking down old one of any type/size complete all as specified and as directed.
1
-
-
... More
Supply and fixing in replacement flex glow sign board of size 2 x 1 x 0.25m with acrylic sheet at front side and GI sheet of thickness not less than 1mm at all other sides of box with aluminium/ structural steel section as frame complete including necessary lighting arrangment inside the box with 02 Nos LED tube light fittings of 1 x 20/18 watt ( T-8 lamp) at top and bottom portion of sign board and its connection terminals with 1.5 Sq mm, 2 core PVC insulated copper conductor from sign board to terminal box/ceiling rose to connect external power supply, complete assembly to be fixed to wall/ angle iron frame in E/M installation with necessary fixing arrangement, the complete assembly should have water tight seal packing connected with screws complete all as specified and as directed Note:
(i) Rough drawing /details like name of installtion /sign board etc (Hard copy) of sign/ letters/ symbols will be given by Department. The contractor has to develop the same with legends/ signs as per the standards on computer in multicolour and same get it approved from Engineer-in-Charge . (ii) Rate includes the glow sign board of required size with flex, necessary lightning arrangment including connection terninals angle iron frame for fabrication of sign board and supporting clamps.
(iii) The contractor has to take prior approval from Engineer in-Charge regarding the specification of sign board like color of acrylic sheet and letters.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%