Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686291_1Tender No
8417_GE_NWTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Material and labour for Machine pressed precast concrete interlocking paver block any shape and size as approved conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment,over and including provision of 30mm thick coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm Spreading and levelling in layers n exc. 25cm thick and well ramming including watering as required complete all as specified and as directed
50
-
-
Material and labour for 75mm thick plain cement concrete 1:4:8 (40mm graded stone aggregate) type D2, as in sub base complete all as specified and directed
100
-
-
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
10
-
-
Material and labour for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate) as in coping or chamfered on edges and similar articles including necessary form work complete all as specified and as directed
0.99
-
-
Supply and fix rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed.
3000
-
-
Supply and fix prepainted galvalume zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to rain water gutters fixed with self tapping screws complete all as specified and as directed.
100
-
-
Supply and fix prepainted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed.
1600
-
-
Dismantling Asbestos cement (corrugated,semicorrugated, etc.) sheets any gauge thickness incl roof/Wall covering complete all as specified and directed
1700
-
-
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed .
30
-
-
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and as directed .
6
-
-
M&L 2nd class HW Weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed .
30
-
-
M&L for 2nd class hard wood in scantling clean sawn fixed as in purlins, rafters, etc in roof complete all as specified and directed .
3
-
-
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including frame work cover fillets etc complete all as specified.
1400
-
-
S&F Aluminium snap grid false ceiling on frame work of aluminium angle 25x25x2 mm, Main TEE 38x25x1.5 mm and cross TEE 25x25x1.4 mm and size of grid 605x605 mm with hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.50 mm dia, 40 mm long with and including provn of 12mm thick mineral fibre ceilingg boards fixed to aluminium frame work with screws including preparation of new ceiling surfaces and applying one coat of white washing to new ceiling surfaces including preparation of surfaces complete all as specified as per manufacturer's instructions and all as specified and directed.
1100
-
-
S&F Aluminium snap grid false ceiling on frame work of aluminium angle 25x25x2 mm, Main TEE 38x25x1.5 mm and cross TEE 25x25x1.4 mm and size of grid 605x605 mm with hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.50 mm dia, 40 mm long with and including provn of 12mm Perforated gypsum ceiling board for insulation and acoustic purposes (wall), 60x60 cm in size, fixed with nails to timber framework or with staples on snap grid frame work including preparation of new ceiling surfaces and applying one coat of white washing to new ceiling surfaces including preparation of surfaces complete all as specified as per manufacturer's instructions and all as specified and directed.
300
-
-
S&F 200 mm dia half round or 180 mm width rectangular PVC SWR ready made eaves gutter of pressure rating 6 Kg/cm2 of approved make including necessary fitting like bend, MS Clips etc complete all as specified and directed .
100
-
-
S&F 150mm dia PVC (SWR) pipe single socketed in any length with rubber joints including necessary fitting like bend, MS clips etc fixed on walls complete all as specified
100
-
-
M&L 75mm thick PCC (1:3:6) type C-2 (Using 40mm graded crushed stone aggregate) as in plinth protection /hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed.
77
-
-
M&L for chequered colour cement concrete tiles 30x30cmx 25mm thick set jointed grey and pigment and pointed in neat cement slurry in floors/steps including screed bed or bedding layer of mortar 15mm thick in cm 1:4 complete all as specified and directed
50
-
-
M&L for Hardcore of broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface all as specified
10
-
-
Taking down Copper/ aluminium point wiring (light, fan, socket, bell, power point) complete fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting any type, building security light removing materials to store for keeping in safe custody for taking credit to match with existing surface complete all as specified and directed.
39
-
-
M&L for point wiring with 1.5 Sqmm PVC insulated sheathed FRLS multistranded single core copper conductor cable in PVC concealed conduit rigid non-metallic (ISI marked) fixed concealed on wall/ roof except beam, column and RCC roof including chases cutting incl suitable size/ cap of sunken box for modular switch and socket and modular white cover plate, flush metal box etc including 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light point controlled by one switch and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-Charge
30
-
-
All as per item No. 25.00 here-in-before but for one 3 pin 5 Amps socket outlet point controlled by one switch on independent board
3
-
-
All as per item No. 25.00 here-in-before but for 5 pin 5 Amps socket outlet point on same board
4
-
-
All as per item No. 25.00 here-in-before but using 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable and 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable earth wire with terminal box of suitable size of modular switch & socket for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
2
-
-
Supply and fix Modular switch, 1way ,6A,1 module complete all as specified and directed
39
-
-
Supply and fix modular socket,6A,2/3 pin combined 2 module complete all as specified and directed
7
-
-
Supply and fix modular socket shutter type 6A/16A,2/3 pin combined 2 module complete all as specified and directed
2
-
-
Supply and fix Modular switch, 1 module, 15A,1 way SP complete all as specified and directed
2
-
-
Supply and fix ceiling rose three terminals polycarbonate , isolated body complete all as specified and directed
30
-
-
S&F in repair recessed mounted 2 feet by 2 feet LED flat panel with high brightness with glare free recessed mounted 36 Watt fittings, 240 Volts, 5700 K, Premium signature series, including all connection where required some copper conductor 1.5 sqmm, complete all as specified and as directed by the Engineer-in-Charge. Make:- Crompton Cat Part No. LCTRI-36-CDL or equivalent manufacturers mentioned in list of manufacturers
30
-
-
S&F in replacement of Factory made singe phase and neutral sheet steel made out of CRCA 1.2mm thick powder coated double door vertical distribution board 4 way dust and vermin proof fitted with two cover, one screwed cover for incoming and outgoing MCB's and second for protection of MCB's fitted with colour bus bar of capacity 200A, neutral link, earth bar and din rail suitable for use on 240V, 50Hz supply, partly immersed in wall and making good disturbed surfaces with matching colour complete all as specified and as directed.
3
-
-
S&F MCB SPN 32 Amp rating 240V, 10KA, 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
3
-
-
S&F MCB SP 6A - 32 Amp rating 240V, 10KA, 'B' curve in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
6
-
-
Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB's (single phase or three phase) of any capacity all as specified and directed.
3
-
-
Taking down carefully old unserviceable sub main wiring including making good disturbed surfaces and matching with existing complete all as directed and specified.
30
-
-
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete complete all as specified and directed.
20
-
-
M&L in replacement of sub main wiring with 2 runs of 4 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable drawn in and including ISI Marked, medium grade, non metallic, Fire Resistant PVC Casing & Capping and all accessories, with 1 run of 4.0Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity wire and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc. complete all as specified and as directed Note:- Three runs of cable and one run of PVC casing and capping shall be measured as one unit
30
-
-
M&L earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below normal ground level surrounted from all side by 15 cm of thick and packed layers of charcoal dust and common salt ,filling alternate layers and electorde connected by using GI wire 4 mm dia (max -length of 7.5 mtrs ) by means of bolts,nut and washer of GI and providing GI light grade pipe 15 mm dia as protection pipe for GI wire connected main controll board / test point and provided with GI pipe of light grade 20 mm bore for watering and including funnel,wire mesh PCC chamber of 1;3;6 type C1 ,and RCC cover of 1;2;4 type B1 including necessary earth work in any type of soil /strata disposal of soil all as directed and shown in electrical plate No. 3 of SSR part -1 removing all Tiles before starting earthing work and laid the Tiles in same place after comletion of earthing and testing on completion also.
1
-
-
Amount of Schedule of credit of for Rs 1,13,795.00 shall be deducted from quoted amount.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%