Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date29 Jan 2025
Closing Date19 Feb 2025
Tender Amount₹ 39,50,000 
Notes
Download

Costs

Summary

Provision Of Recd Devices For Dg Sets Of Various Capacities Installed Under Aorm Of Ge (i) (cg) Kochi And Provision Of Sprinkling System At Armoury Cgae, Kochi

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and installation of pump set monoblock type pump set electrically driven 2 HP, and a speed of 2840 rpm,415 V, three Phase and a power rating of 1.5 kW, Casing Material: Cast Iron, Motor Body Material: Cast Iron, Shaft Material: Carbon Steel.The pump has a discharge range of 2.2-4.1 lps and head range of 15-25 m with suction pipe with inlet/outlet of 50/40mm dia, with and including cast iron foot valve of suitable size and connection from starter to motor using suitable size copper cable all complete including necessary items all as specified and as directed. Make : Model No.KDS-225++ of Kirloskar or equivalent in Crompton Greaves/Havells/KSB.

1

-

-

... More
Supply and installation in repair, testing and commissioning of pressure Guage, 100mm & 0 to 14 kgs rating all as specified and directed by the Engineer-in-Charge. Make : H. Guru/Equivalent conforming to relevant IS.

1

-

-

... More
Supply and installation in repair, testing and commissioning of pressure switches universal type nall all as specified and directed by the Engineer-in-Charge. Make : Indoss/Danfoss.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Automatic Fire Hydrant and Sprinkler System Panel for 2 Nos of Main Electrical Motor Driven Pump, a Diesel Engine Driven Pump,2 Nos of Jockey Pump, incorporating automatic direct online switchgear rated for the motor HP. The Control panel mounting shall include necessary indications lamps for the RYB phase showing the power supply conditions ammeter with clear indications or motor full load current, voltmeter with selector switch etc.(As per electrical Inspectorate Standard) with internal cabling, complete all as specified and directed by the Engineer-in-Charge. Make:Newage

1

-

-

... More
Supply and fixing ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed suitable for 20 mm ISI marked and taking down unserviceable ball valves all as specified and as directed.

1

-

-

... More
Supply and fixing ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed suitable for 40 mm ISI marked and taking down unserviceable ball valves all as specified and as directed.

1

-

-

... More
Supply and fixing cast iron non return valve, 100 mm dia approved make complete all as specified and directed.

1

-

-

... More
Supply GI Fire Bucket Stand of size 800 X 1240 X 400 mm, with canopy made of GI sheet 22 SWG for occupaying fire bucket having 4 hook and painted with pure polyster corrosion resistant powder coating Shade as per IS 536 complete all as specified and directed

1

-

-

... More
Supply of Analogue Addressable Multisensor (Smoke & Heat) detector with standard base having capacity of min 125 detectors per loop. The detector must be polarity insensitive & smart addressable type. The detector must be tested from TF2,TF3,TF4,TF4,TF5 type of fires as per EN54 standards. Detector must have have insect protection facility for ants and flies with extra metalic mesh pattern. Operating temperature (Transient) - 10°C to 85°C & Humidity 0-95% (Non-condesation or icing). The detector should have dual polling 360 degree viewable LED with class approved response modes for smoke & response heat modes as per the EN54 part 5 & 7 approval.The detector should trigger heat alarm to 55,65,75 or 85°C .The detector shall have facility to mount in different comprehensive environment like Hostile environment, Parking Garage, Precious storage, Ware house and normal working environments. The detector should have self locking mechanism,which can be easily removed.The detector must have non volatile memory to feed the installation date & site codes. It should be made up of ABS material (Flame retardant94V0 rated) & should melt above 200 degree C.The terminals for the base and the detector must be nickel plated steel to avoid the corrosion and to ensure the connectivity .The detectors must be openable for the cleaning whenever required. The detectors must adhere to the stringent Electrical Stability and Electromagnetic Compatibility (EMC) Immunity tests & vibration test in accordance with the EN54 standards(Approval: EN54 part 5,7, part13 System approval 2017+A1: 2019 with CE Mark). including extending armoured copper cable 2 x 1.5sq.mm. up to a length of 5 mtr complete all as specified and directed. Make:Newage Nextgen Pro

4

-

-

... More
Supply and fixing of Audio Alarm Hooter 60 / 80 / 120 dB sound level adjustable with inbuilt volume control, Flush panel mounting / Wall mounting, Dust and Vermin proof enclosure, Audible distance : 80/100/120 meters testing all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Supply, fixing and testing of Addressable manual call point, IP67, resettable type with 470 Ohm resistor and Normally Open contact, complete with glass complete all as specified and directed by the Engineer-in-Charge. Make : Ravel/Morley/Siemens/ Asses/Agni

1

-

-

... More
Supply and installation of FIRE RESISTANT - FIRE ALARM CABLE 2 Core - 1.5 Sq. mm (FRLS Armoured cable) complete all as specified and directed

30

-

-

... More
Supply and installation of ravel fire alarm panel 2 zone (RE-102-R ) conforming to IS -15908: 2011 Standard, of size (350W X 250H X 100D) , made in 18 Gauge (1.22mm) CRCA sheet with powder-coated finish, IP50 , having 16 X 2 Dot Matrix LCD Display, Standby battery backup with built in charging, Fire / Fault status in unambiguous coloured LED indication, Tactile Keypad for easy panel operation, System ON indication, Main, Standby status indication, Low Battery visual warning with audible tone, Relay output for actuators, for Fire and Fault, Zone wise one man Walk Test Facility, complete all as specified and directed

1

-

-

... More
Supply and fix Rotational moulded polyethylene water storage tanks having capacity 1000 Ltrs (cylinderical vertical with closed top) hoisted and fixed in position including ball brass valve 40mm complete all as specified and directed.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 6 kVA Online Parallel redundant UPS with SNMP facility and Isolation Transformer operating on 415V, 50Hz, 3 phase Input and Single phase Output with interconnecting suitable cable, Interconnecting 1 x 16 Sq.mm size copper cables or suitable cable between UPS and Switches & Batteries, UPS Body and Body Earth, as per actual site requirements

1

-

-

... More
Removing the old silencer and replace with Retrofitted Emission Control Equipment / Devices (RECD) of 160KVA DG set having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. type approved by one of the five Central Pollution Control Board (CPCB) recognized labs. The emission limits and parameters for DG sets shall be as per CPCB-II norms. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system complete all as specified and directed.

1

-

-

... More
Removing the old silencer and replace with Retrofitted Emission Control Equipment / Devices (RECD) of 250KVA DG set having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. type approved by one of the five Central Pollution Control Board (CPCB) recognized labs. The emission limits and parameters for DG sets shall be as per CPCB-II norms. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system complete all as specified and directed.

1

-

-

... More
Removing the old silencer and replace with Retrofitted Emission Control Equipment / Devices (RECD) of 125KVA DG set having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. type approved by one of the five Central Pollution Control Board (CPCB) recognized labs. The emission limits and parameters for DG sets shall be as per CPCB-II norms. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system complete all as specified and directed.

1

-

-

... More
Removing the old silencer and replace with Retrofitted Emission Control Equipment / Devices (RECD) of 200KVA DG set having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. type approved by one of the five Central Pollution Control Board (CPCB) recognized labs. The emission limits and parameters for DG sets shall be as per CPCB-II norms. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system complete all as specified and directed.

1

-

-

... More
Removing the old silencer and replace with Retrofitted Emission Control Equipment / Devices (RECD) of 400KVA DG set having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. type approved by one of the five Central Pollution Control Board (CPCB) recognized labs. The emission limits and parameters for DG sets shall be as per CPCB-II norms. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system complete all as specified and directed.

1

-

-

... More
Removing the old silencer and replace with Retrofitted Emission Control Equipment / Devices (RECD) of 100KVA DG set having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. type approved by one of the five Central Pollution Control Board (CPCB) recognized labs. The emission limits and parameters for DG sets shall be as per CPCB-II norms. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system complete all as specified and directed.

1

-

-

... More
Schedule of Credit (Minus) Rs.8190.00 NOTE: Bidder shall insert credit amount of Rs. 8190.00 as rate in Green field under Col-13.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.