Military Engineer Services Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 36,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_644833_1Bid Award Id
ViewTender No
CWE(NW)KOCHI/81426Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Note :- (a) The comprehensive maintenance and complete allied works shall be done through OEM agency i.e Blue Star/authorised dealers. Comprehensive maintenance contract shall be done for the complete Higher side Machineries of the AC Plant. (b) The above comprehensive AMC certificate shall be provided by the contractor in favour of GE(NS) before commencement of work, after acceptance of CA (c) The higher side of AC plant defects shall be get checked by OEM ( Carrier air conditioning and Refrigeration Ltd) and made serviceable in case of any defects observed during the routine check up or on call during emergency breakdown including replacement of all minor spares ,Leak detection ,pressure testing with nitrogen ,vacuumising,Labour for compressor oil charging, and testing if required complete all as specified and directed. (d) The quoted rate including repalcement/repair of any kind of spares labour cost for replacement of defective spares which are excluded by OEM on Comprehensive AMC .The quantity of materials may vary and excecuted at site only on required basis.
(e) Any complaints shall be attended within 24 Hrs the same day of complaint lodged by MES authority or user (INHS sanjivani) (f) Consumable items which are excluded in CAMC by OEM like (refrigerent,filters/driers,compressor oil etc) are measure and paid under relevent items as supply only. (g) The contractor has to submit no dues certificate from the OEM before completion of work.
-
-
-
Supply only Refrigerant Gas R 134 A in sealed cylinder,all as specified and as directed .
61
-
-
Supply only Nitrogen gas in sealed cylinder comprising of 12 PSI gas 6 cum in all as specified and directed.
2
-
-
Supply only Internal oil filter as per existing at site complete all as specified and directed
1
-
-
Supply only External oil filter as per existing at site complete all as specified and directed
1
-
-
Supply only Filter drier core as per existing at site complete all as specified and directed
1
-
-
Supply only Compressor Oil suitable for R-134 A refrigerent based Model CHFL-Y24 screw chiller all as specified and as directed .
5
-
-
Supply and fixing Chilled water thermister sensor with controlling cable as suitable for existing chiller socket/groove for existing chiller units complete all as specified and as directed.
2
-
-
Supply and fixing temperature sensor with cable complete all as specified and as directed
2
-
-
Taking down old unserviceable canvas form AHUs duct to pleneum/Main supply air duct including dismantle of air dampers/fire dampers and supply and fix new premium quality leather type canvas locking rivits and sealing of silicon material of any size as per existing at site complete al as specified and directed.
2
-
-
Supply and fix in repairs poly F plus PB classical V- Belts suitable for existing AHU motor sizes (any type of any Series) all as specified and directed.Make : Fenner/Dunlopp
20
-
-
Material & Labour for dismantling of side covers of shell and tube type chiller condensor and circulate descaling chemical compound with the help of pressure pump upto 2 hrs and cleaning with nylon brushes and necessary T&Ps and flushing out with fresh water and refixing of condensor side covers with proper gaskets (to be replaced if found damaged) and leak testing upto capacity 130 TR complete all as directed by Engineer-in-Charge .
3
-
-
Comprehensive maintenance and routine check up of following Lower side AC equipments components on monthly basis/as per requirement to ensure the working of all machineries without breakdown of AC supply to the complex with all materials and labour for smooth functioning of plants :-
-
-
-
Cooling Tower of capacity 150 TR - 02 Nos and 90 TR - 01 No ( 2 Nos working and 01 No Standby) complete with all accessories, basin, fittings, cooling tower fan motors - 03 Nos etc (5 HP -02 Nos & 3 HP - 01No) complete all as specified and as directed.
11
-
-
MONTHLY PREVENTIVE WORKS FOR COOLING TOWER
a) Checking & make it Functioning of Tower starter panel.
b) Checking & make it Functioning and tighten cable connection.
c) Checking and cleaning of contractors.
d) Checking and cleaning of CT fan terminals.
e) Checking & make it Functioning and lubricate CT fan motor bearing.
f) Checking & make it Functioning motor Amps.
g) Checking & make it Functioning and washing tower tray and strainer. h) Labour for replacement of fills. i) Checking of fan blades and alignment of sprinkler pipes. j) Checking of Vibration of structure etc.
k) The replacement cost for any kind of material and labour including repair/replacement of cooling tower hub, blade, stay assembly, bearings and motor winding etc shall be deemed to be included in the quoted rate. l) Any breakdown shall be attended within 24 hrs. A penalty of Rs 1000/- per day will be deducted on failuring to attend the complaint within 24 hrs.
-
-
-
Air Handling Units of following capacity :- 10 Nos (Including replacement of defective electrical accessories of AHU, CT, Pump panel' ) (capacity of AHUs as follows) including 10 Nos of electric motors, blower of different cpacities, blower units, cooling coils, valves of differnet sizes, gauges etc including repairs/rewinding of electric motors:-
(i) 18500 CFM - 2 Nos (ii) 16500 CFM - 1 No (iii) 17500 CFM - 1 No (iv) 22500 CFM - 1 No
(v) 23500 CFM - 1 No (vi) 29200 CFM - 1 No (vii) 28200 CFM - 1 No (viii) 12500 CFM - 1 No
(ix) 14500 CFM - 1 No
11
-
-
MONTHLY PREVENTIVE WORKS FOR AHU
a) Repair the components of the AHU equipment at site / Service Station.
b) Checking all electrical controls and components of AHUs. c) Checking and servicing of AHU electrical Panel. d) Lubricating the bearings of AHU motor. e) Adjustment of tension and replacing of AHU blower motor belt if worn out. f) Checking and lubricate of AHU blower bearings. g) Checking & make it Functioning of blower shaft. h) Checking and cleaning of AHU blower. i) Checking & replace with new if found tear/breakng of AHU canvas connection. j) Checking of AHU blower pulley and motor pulley. k) Checking and cleaning of AHU motor terminals. l) Checking of AHU motor amps.
m) Checking of AHU room temperature (return air). n) Checking of room temperature (supply air) q) Checking of thermostat. r) Checking & make it Functioning of humidistat.
s) Checking of AHU heater
t) Checking and cleaning of AHU drain and try
u) Checking and washing of AHU coil with water pressure. v) Checking of CFM, dampers,fuses, motor vibration levels. w) Checking of Air leakage
x) The replacement cost for any kind of spares of motor/pulleys, material and labour including bearing, pulley, motor winding shall be deemed to be included in the quoted rate. y) Any breakdown shall be attended within 24 hrs. A penalty of Rs 1000/- per day will be deducted on failuring to attend the complaint within 24 hrs.
-
-
-
M & L for Monthly servicing of air filters from AHU carefully and cleaning including arrangement of for removing of dust and foreign particles from the AHU rooms/filters/coiling coil throughly by using pressure water jet pumps and suitable washing products to ensure general hygeine and upkeeping of AHU rooms, greasing shaft and bearings, alignment of blower motor, tightening of blower V belt and refixing filters after drying and to ensure the drain lines, strainer, drain pan to arrest the micro/fungal growth inside AHU rooms complete all as specified and directed by Engineer-in-charge.
Note :- (i) Replacement of Air Filter shall be resposibility of contractor if damage occur while removing or refixing.(ii) Servicing of one complete AHU will be considered as one job (iii) Cleaning of plenum and supply and return diffusers