The Marine Products Export Development Authority Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MPEDA_508982_1Bid Award Id
ViewTender No
LAB/ELEC/1/2019-QCTender Authority
The Marine Products Export Development Authority ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, Fixing, testing and commissioning Pillar tap ( long body swan neck half shut multi utility taps) for wash basins with all accessories.
Make: KOHLER, CERA ,JAGUAR or equivalent.
1
-
-
Supply, Fixing at site long Towel rail with CP flanges, fixed with SS screws complete.Small size
Make: KOHLER, CERA ,JAGUAR or equivalent.
2
-
-
Supply,Fixing, testing and commissioning at site 40mm dia CP Bottle Trap For Wash Basin of approved make complete Make:Kohler and equivalent
1
-
-
Hand Dryers with sensor: Supply installation and fixing
2
-
-
Soap Solution Dispenser, Push button type (SS)
8
-
-
WATER SUPPLY (INTERNAL): Providing, Fixing, testing and commissioning at site CPVC Pipes of approved make cutting to din standard ( 8077 or 8078 ) For Cold Water Supply with Malleable Specials such as tees, elbows, check nuts, unions, flanges, nipples, etc including cutting, threading, fixing in/on walls, ceiling, under floor etc. as per drawing. The quoted rate shall include for necessary excavation, backfilling, chasing the walls, making bore in walls etc.,& making good the chased surfaces & bores in cement mortar, hanging clamps & anchor fasteners wherever required etc. complete
-
-
-
20 mm dia. CPVC Pipe SDR 11( Concealed) Providing & Fixing
80
-
-
Providing, Fixing, testing and commissioning at site in positions as detailed in drawings, forged brass Ball Valves complete in all
respects.20mm dia
3
-
-
50 mm dia. CPVC Pipe SDR 11( Concealed) Providing & Fixing
30
-
-
Providing, Fixing, testing and commissioning at site in positions as detailed in drawings, forged brass Ball Valves complete in all
respects.50mm dia
3
-
-
INTERNAL SOIL & WASTE PIPES
Providing, Fixing, testing and commissioning at site in position u PVC pipe of 6Kg/sq.cm (IS:4985) including PVC fittings with bosses where required e.g.tees, bends, clambs, coupling and adapters and jointing with adhesive approved by fitting manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site euniversal clamps & anchor fasteners(8mm) , threaded rod(8mm),nuts ,washers, wherever required etc. complete. (For Internal waste line) Providing,Fixing, testing and commissioning at site in position u PVC pipe of 6Kg/sq.cm (IS:4985) including PVC fittings with bosses where required e.g.tees, bends, clambs, coupling and adapters and jointing with adhesive approved by fitting manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site euniversal clamps & anchor fasteners(8mm) , threaded rod (8mm),nuts ,washers, wherever required etc. complete. (For Internal waste line)
-
-
-
50mm
120
-
-
38 mm
60
-
-
Providing, Fixing, testing and commissioning at site in position UPvc fabricated floor trap, bose tee/deep seal floor trap with suitable SS gratings supporting on GI slotted rails (1.6mmthick) full threaded rod, anchor fasteners etc.50/75 mm dia outlet
2
-
-
INTERNAL ELECTRICAL WORK POINT WIRING-LIGHT POINT
Supply & Wiring of Light point using 3 Runs of 1.5 Sq.mm 1.1 KV grade ISI marked PVC insulated FRLS single core stranded copper wire through 20/25 mm dia. medium duty electrical grade ISI marked PVC conduit in recessed system including supply & fixing of 1 No.6A one way Modular type control switch,6A Socket with base plate / cover, suitable metal boxes, inter connections , earthing the box etc. complete as required.(wires make:V guard, Finolex or Equivalent, switches Make: Legrand‐Mylink, L&T, MK or Equivalent.
-
-
-
One light point controlled by 1 No. 6A 1 way switch
3
-
-
Two light point controlled by 1 No. 6A 1 way switch
10
-
-
Three light point controlled by 1 No. 6A 1 way switch
4
-
-
Four light point controlled by 1 No. 6A 1 way switch
9
-
-
Wiring generally same as above [ Item No.1.a] but for Two light point controlled by 2 nos. 6A 2 Way switch
Wiring generally same as above [ Item No.1.a] but for Two light
1
-
-
Wiring generally same as above [ Item No.1.a] but for Two light points controlled by 2 nos. 6A 2 Way switch
1
-
-
Ten light point controlled by 1 No. 6A 1 way switch
Feed from UPS DB for emergency light.
1
-
-
WALL FAN / LIGHT POINT:
Supply & Wiring of Wall fan point using 3 Runs of 1.5Sq.mm
1.1 KV grade ISI marked PVC insulated FRLS single core stranded copper wire through 20/25 mm dia. medium duty electrical grade ISI marked PVC conduit in recessed system including supply & fixing of 1 No.10A one way Modular switch with base plate / cover, suitable metal boxes, inter connections, earthing the box etc. complete as required.
-
-
-
One fan point controlled by 1 No. 6A 1 way switch
8
-
-
CIRCUIT & POWERPOINT WIRING
-
-
-
Supply & Wiring of circuits using 3 Runs of 1.5 Sq.mm. 1.1 KV grade ISI marked PVC insulated FRLS single core stranded copper wire through 20/25 mm dia. medium duty electrical grade ISI marked PVC conduit in recessed system.
800
-
-
Supply & Wiring of Power Points using 3 Runs of 2.5 Sq.mm. 1.1 KV grade ISI marked PVC insulated FRLS single core stranded copper wire for earthing through 20/25 mm dia. Medium duty electrical grade ISI marked PVC conduit should be done over Surface, Open, Concealed type with. Air Curtain & 16 Sockets UPS Supply.
2380
-
-
Supply & Wiring of Power Points using 3 Runs of 4 Sq.mm. 1.1 KV grade ISI marked PVC insulated FRLS single core stranded copper wire for earthing through 20/25 mm dia. Medium duty electrical grade ISI marked PVC conduit in recessed system. For Split Air Conditioners. (Maximum 3m to 5m distance between switch and socket)
800
-
-
POWER OUTLETS / SWITCHES
Supply, Fixing, testing & commissioning of the following Modular type 230V Plug Sockets, Controlling Switches with suitable size metal box , inner base plate , outer cover, termination of wires, earthing the box etc.complete as required switches Make:Legrand‐Mylink, L&T,MK or Equivalent
-
-
-
1 No. 6A 2/3 pin combined Modular type shuttered socket controlled by 1 No .one way 6A SP switch (With Light point switch)
20
-
-
2 No.6/16A 3 pin combined 2 gang modular type shuttered socket controlled by 2 No. one way 16A SP switch with indicator (for UPS out lets)
50
-
-
1 No.6/16A 3 pin combined modular type shuttered socket
[for AC Unit] controlled by 1No one way 16A switch with indicator mount in an independent position with 16A 3 pin top. (Maximum 3m to 5m distance between switch and socket)
10
-
-
1 No.6/16A 3 pin combined modular type shuttered socket controlled by 1 No. one way 16A SP switch with indicator (for Air curtain)
20
-
-
1 No 32 A 3 pin Industrial socket (shuttered) socket controlled by 1 No 32 A MCB Full set with 3 pin industrial top.(for instruments)
20
-
-
Supply and installation of 32A TPN Isolator with enclosure outlet mount in an independent position Using 4c x16 Sq mm Aluminum armored cable fed from SB.
1
-
-
LIGHT FITTINGS (Supply & Fixing)
Supply, Installation, testing and commissioning of following Light fittings with necessary fixing accessories required for installation, complete as required. (Samples to be approved by
the Client)
-
-
-
18W LED Panel ceiling light, Make:Philips,Syska or Equivalent
37
-
-
11 LED Panel ceiling Light Make:Philips,Syska or Equivalent
18
-
-
18W LED Surface mounted Light (4ft), Make:Philips,Syska or Equivalent
13
-
-
18W Wall mounted Light Make:Philips,Syska or Equivalent
2
-
-
11 LED 3 inch round ceiling Light Make:Philips,Syska or Equivalent
10
-
-
Exhaust Fan 8’’ Make:Philips,Syska or Equivalent
4
-
-
Ceiling Fan 1200mm Make:Philips,Syska or Equivalent
4
-
-
Installation, testing and commissioning of the following ceiling fans, exhaust fans as per standards with all wiring, terminations, interconnections etc. complete as required
4
-
-
POWER CABLING: MCB Distribution Box and Enclosure: Supply, Erection, Testing and Commissioning of the following double door type MCB Distribution Boards with RCBO / Isolator at the incomer side and MCBs on the outgoing side. The work includes termination of incoming and outgoing wires, cables, conduits and earth wire.
-
-
-
8WAY TPN MCB D.B. (LDB)
8Way TPN MCB DB with three phase incomer and single phase out goings as per the following.
Incomer: RCBO 32A, 4Pole with O/C & 30mA Earth Leakage trip – 1No.
Outgoings: MCB 6A , SP –21nos.
Supply : Labour / Installation / Erection:
1
-
-
12WAY TPN MCB D.B. (UPS DB)
12Way TPN MCB DB with three phase incomer and single phase out goings as per the following.
Incomer: RCBO 32A, 4Pole with O/C & 30mA Earth Leakage trip – 1No.
Outgoings: MCB 16A , SP – 30 nos.
MCB 16A , SP – 2 nos. (Spare)
Supply : Labour / Installation / Erection:
1
-
-
24 WAY TPN MCB D.B. (PDB - 1) Vertical
-
-
-
24Way TPN MCB DB with Three phase incomer and single phase out goings as per the following
Incomer: RCBO 63A, 4Pole with O/C & 100mA Earth Leakage trip – 1No.
Outgoings: MCB 16A , SP – 24 Nos for Air conditioners and Air curtains.
Supply : Labour / Installation / Erection:
2
-
-
8WAY TPN MCB D.B (DG Backup for freezer)
-
-
-
8 Way TPN MCB DB with Single phase incomer and single phase out goings as per the following.
Incomer: RCBO 63A, 4Pole with O/C & 100mA Earth Leakage trip – 1No.
Outgoings: MCB 16A, SP – 6 nos.
MCB 16A , SP – 4 nos. (Spare)
Supply : Labour / Installation / Erection:
1
-
-
POWER SIDE ELECTRIFICATION
LT ARMOURED CABLING WORK, SUPPLY & LAYING OF CABLES: Supply, Laying, testing and commissioning of the following PVC Insulated Armored Aluminum L.T.Cables (AYWY/AYFY) with suitable copper conductor for earthing, Cable glands, copper crimpled type cable lugs, etc. including supply and fixing of clamps, nuts and bolts, screws, identification tags, route markers etc. required for clamping intervals as necessary. Cables laying through walls/floor/false ceiling (counseled/open) as per the site condition.
-
-
-
4CX 16 SQMM AYFY (PDB 1&2, 8way DB DG backup for Freezer)
Supply and Laying
1
-
-
4CX 10 SQMM AYFY (LDB): Supply and Laying
1
-
-
1.1KV GRADE AYFY/AYWY ARMOURED ALUMINIUM CABLES
4CX 50 SQMM AYFY (MSB to SB): Supply and Laying
1
-
-
Sub Distribution Board (SB)
-
-
-
Top cable entry for incoming and outgoing feeders. Fabricated out of 16SWG CRCA sheet.
1) Bus bars: 100A TPN Al. Busbar - 1no. 2) Earth bus - 25 x 3mm CU
3)Incomer: 100A 4P SFU Switch -1no
4) Meters & Indications:Red, Yellow, Blue LED Indication Lamps along with 3nos 2A Control fuses - 2sets. KWH Meter with RS485 Port -1Set
5) Outgoings: 32A TPN Miniature Circuit Breaker – 1 no. (spare)
32A TPN Miniature Circuit Breaker – 1 no. (LDB)
63A TPN Miniature Circuit Breaker – 2 nos. (PDB- 1& 2)
32A TPN Miniature Circuit Breaker - 1 nos UPS incomer supply
Design, Supply & Fabrication, Installation / labour.
1
-
-
DEMOLISION:
-
-
-
Dismatling existing wiring ,cable DB etc
1
-
-
EARTHING.Supply, laying & clamping at site Copper earthing conductors inclusive of providing earthing terminations and bracing of the terminations etc.
-
-
-
2RX1CX 16 SQMM Copper Wire for dedicated earthing Supply, Labour& Errection
1
-
-
25x 3 mm Copper Strips. Supply , Labour& Errection
1
-
-
10SWG Copper wire. Supply , Labour& Errection
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements