KITCO Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_KITCO_287229_1Bid Award Id
ViewTender No
STDD/KITCO/EL/04/2019Tender Authority
KITCO Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Service of one set AB switch in the existing Four pole Structure (Three No.s) with all the necessary accessories etc.as required.
2
-
-
Dismantling of existing CT PT unit, supply and installation of new CT PT unit with accuracy class 0.2S in the existing four pole structure with all the necesaary accessories etc. as required.
1
-
-
Supply, installation, testing and commissioning of TOD meter with accuracy class of 0.2S and test terminal block, control fuses, armoured copper cable between CT PT unit and TODmeter with all the necessary accessories.
1
-
-
Repainting of 160 KVA outdoor transformer, ONAN, DYN11 (Make- KEL)
- All steel work surfaces shall be thoroughly cleaned of rust, scale, welding slag or spatter and other contamination prior to any painting.
- Suitable anti-corrosion protection
- One coat of enamel primer followed by two coats of synthetic enamel painting shall be done at site using spray painting.
1
-
-
Servicing of 160 KVA outdoor transformer, ONAN, DYN11 (Make- KEL) including 1 Checking of the general conditions
2 Checking of connections and observe vibrations or noise
3 Checking of terminal connections and earthing connections for tightness
4 Oil filtration, oil topup and replacing silica gel
5 Checking of oil level in the conservator
6 Verification of condition of oil and verification of dielectric strength of oil if necesary.
7 Checking for unusual internal noise
8 Checking of breather
9 Checking of explosion vent diaphragm
10 Checking of fuse and earthing mechanism
11 Checking of alignment of moving and fixed contact
12 Lubrication of Mechanism Cost of additional oil if required will be paid as per the actual invoice provided.
1
-
-
Servicing, overhauling, repairing, testing and commissioning of 250 KVA Diesel Generator Set (Model: Kirloskar Green).The bidder has to visit the site and assess the actual condition of the DG Set before quoting.
Material (The cost of spare parts shall be reimbursed on production of actual Bills)
1
-
-
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
200
-
-
Cable meggering of HT cables including removing the termination, testing and reconnecting of cable glands with all the necessaory accessories required. The contractor has to bring the necessary equipment required for testing.
1
-
-
Cable meggering of LT cables including removing the termination, testing and reconnecting of cable glands with all the necessary accessories required.The contractor has to bring the necessary equipment required for testing.
22
-
-
Cleaning trenches and laying chequered plates inside electrical room including neatly dressing the cables in the tray
150
-
-
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
-
-
-
3.5Cx35 sq. mm
230
-
-
4Cx6 sq. mm
60
-
-
Supplying and making end termination with brass compression gland and aluminium/Copper lugs for following size of XLPE insulated PVC sheathed aluminium/copper conductor cable of 1.1 kV grade as required.
-
-
-
3.5Cx35 sq. mm
4
-
-
4Cx6 sq. mm
2
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
250
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
30
-
-
Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required
25
-
-
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
3
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, with modular switch, modular plate, on existing GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
125
-
-
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, on existing GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.. (Note:The total distance from the switch box to the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 22.01)
26
-
-
Group controlled light point with 1.5 sq. mm wire - Wiring for Group controlled light point (from one point to another point) with 3X 1.5 sq. mm PVC insulated, (FRLS), copper conductor cable in exsting surface/recessed mounted rigid medium class 20mm PVC conduit with all accessories as required. ( Note: This item does not include the cost of MCB or 16Amp/ 6Amp one way switches. The total distance from one point to another point will not exceed 5meters. In case if the total length increases 5meters, the additional lengtth shall be measured under item 22.01. The distance from DB to 1st point will be measured under item point wiring.
2
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed medium class PVC conduit as required
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
776
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
946
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
484
-
-
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
88
-
-
Supplying and fixing following modular switch/ socket with modular plate & plate & cover on surface or in recess on existing GI box, inter connection etc as required complete.
-
-
-
Telephone socket outlet
4
-
-
TV antenna socket outlet
4
-
-
Bell push
4
-
-
Supplying and fixing stepped type electronic fan regulator with modular plate & cover on surface or in recess on existing GI box,inter connection etc as required complete.
20
-
-
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
4
-
-
Supplying and fixing modular plate and cover in front on surface or in recess on existing GI box, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
12
-
-
Supplying and fixing modular plate and cover in front on surface or in recess on existing GI box , including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
72
-
-
Supplying and fixing following size/ modules of GI box in recess as required.
-
-
-
1 or 2 Module
5
-
-
4 Module
5
-
-
8 Module
5
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
2 Pair
150
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
100
-
-
25 mm
50
-
-
32 mm
15
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
2
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
4
-
-
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required.
-
-
-
4 pole 63 amps. (415 Volts),100mA sensitivity.
2
-
-
2 pole 25 amps. (240 Volts), 30mA sensitivity.
4
-
-
Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required.
-
-
-
6A to 32A, SP, C-CURVE
88
-
-
6 A to 32 A TP MCB, C-CURVE
2
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
22
-
-
Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 20+/-2 Watts,lumen output of lamp greater than 1500, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Philips BN021C LED20S PSU NW GR or Wipro LL20-221-XXX-65-XX or Crompton Greaves DMLN1LT16+LT16 or equivalent approved makes
33
-
-
Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 10+/-2 Watts,lumen output of lamp greater than 800, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Philips BN021C LED20S PSU NW GR or Wipro LL20-121-XXX-60-XX or Crompton Greaves DMLN1LT16+LT8 or equivalent approved makes
16
-
-
Supply of IP65 streetlight luminar made of die cast aluminium along with driver,system wattage of 30+/-2 Watts,lumen output of lamp greater than 3000 lumens, power factor 0.9,rated life of L70 @ 50,000 hours system efficacy greater than 95 lumen/watt ,wth suitable driver and including all necessary accessories as required complete.(Make:- Cat No: Wipro LR02- 331-XXX-57-XX or other approved equivalent makes)
6
-
-
Supply of decorative wall light 12W CFL lamp including supply of lamp and all other accessories as required complete. Sample of the material shall be approved by Engineer in charge. (The purchase price of the fitting should be taken as Rs.1925/each and any deviation plus or minus in the purchase price in approved shade will be adjusted in the price quoted).
26
-
-
Supply of indoor decorative IP44 wall light with provision of End to End connection,along with driver,system wattage of 8+/-2 Watts,lumen output of lamp greater than 800, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete. Sample of the material shall be approved by Engineer in charge.(The purchase price of the fitting should be taken as Rs.2632/each and any deviation plus or minus in the purchase price in approved shade will be adjusted in the price quoted).
16
-
-
Supply of following sizes of 1200 mm sweep. 5 star rated ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, 30 cm down rod and without speed regulator suitable for 240V 50 HZ, AC supply confirms to IS 374/1979 as required complete. (Make crompton-High breeze or equivalent approved make).
20
-
-
Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton Brisk Air or equivalant approved make)
16
-
-
ITC LIGHT FITTINGS AND FANS
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
97
-
-
Installation, testing and commissioning of MS tubular swaged plole of total height 5m with swan neck to fix CFL type light fittings. The pole shall have outside dia & thickness as 88.9x4.0,76.1x3.25, & sectional length 3 mtr+2 mtrs long, top portion bended to shape. The pole shall have 200 x200 x 6 mm base plate welded at bottom The pole shall have planting depth of 0.5mtr & erected in PCC 1:2:4 including excavation as per the drawing. The pole shall be provided with sintex loop in loop out box with 3 phase power connector or bus bar of required current rating, 2nos 40mm dia GI pipe clamped to the pole for taking loop in loop out cable. Wiring with 3Cx 2.5 sq.mm copper wire from the control box to street light fixture, withsintex / Frp control box with 6 way connectors, 1 no 6A MCB, neutral link and connection to the lamp through the pole, and painting with two coats of primer and two coats of enamel paint as required. (The pole and luminaire will be supplied by the department. The cost shall be inclusive of all other accessories require for the installation of street light luminaire )
25
-
-
Installation, Testing and Commissioning of MS tubular swaged pole SP-12) of total length 8m fabricated with following dia pipes 114.3x5.4 (Bottom),88.9X4.85(middle), 76.1x3.25(top) with a bottom plate of size 350x350x6mm SP-12) of total length 8m fabricated with following dia pipes 114.3x5.4 (Bottom),foundation with a concrete mixture of 1:3:6 circular shape of size 60cm dia and 60 cm above ground level and 1500 m below ground level with bed size of 0.7x 0.7 x 1.5 m as per specification including excavation, wiring with 3Cx 2.5 sq.mm copper wire from the control box to street light fixture, with sintex / FRP control box with 6 way connectors,withsintex / FRP control box with 6 way connectors,1 no 6A MCB, neutral link and connection to the lamp through the pole, and fixing 1no street light luminaire suitable with all the necessary accessories etc. as required.( The pole and luminaire will be supplied by the department. The cost shall be inclusive of all other accessories require for the installation of street light luminaire )
10
-
-
Installation, testing and commissioning of ceiling fan, including fixing the regulator, wiring using down rod of 100cm length using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor etc. as required.
20
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
16
-
-
Numbering of ceiling fan / exhaust fan/ fluorescent fitting as required.
133
-
-
Supply, Installation, Testing and Commissioning of Earthing with C.I. earth pipe 4 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended upto date)
4
-
-
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.
-
-
-
3.15mm Cu (10 SWG)
11
-
-
8 SWG GI
10
-
-
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
-
-
-
3.15mm Cu (10 SWG)
209
-
-
8 SWG GI
50
-
-
Providing and constructing Dry rubble work with hardstone uncoursed for foundations,retaining walls etc including filling the joints /hollows with suitable sizes of split stones,filling the joints clearly, cost and conveyance of all materials, cost of bond stone (should be provided at every 0.5 sqm of face area), lead, lift etc.complete as directed by Engineer-in-Charge.
25
-
-
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
567
-
-
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
8
-
-