Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State IT Infrastructure Limited - KSITIL Tender

Works
Eprocure
Opening Date8 Feb 2024
Closing Date7 Mar 2024
Tender Amount₹ 21,97,95,412 
Notes
Download

Costs

Summary

Interior Fit Out And Exterior Facade Works Of It Facility At Kmrl Metro Station At Ernakulam South

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od301763/2023_2024 : Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

10

-

-

... More
od301764/2023_2024 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including stacking of serviceable material with in 50 metres lead and disposal of unserviceable surplus material or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

10

-

-

... More
od301765/2023_2024 : Dismantling consealed pipe lines (including supply & waste lines) carefully, clearing away and stacking the material in the stockyard within Infopark campus as per directions of Engineer-in-charge

10

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

1

-

-

... More
15.5 : Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge.

0.8

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

1

-

-

... More
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

5

-

-

... More
15.12.2 : Of area beyond 3 sq. metres

5

-

-

... More
15.18 : Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

50

-

-

... More
15.19 : Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.

100

-

-

... More
15.43.2 : Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road

10

-

-

... More
15.44.1 : Dismantling G.I. pipes ( external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges:15 mm to 40 mm nominal bore

50

-

-

... More
15.44.2 : Dismantling G.I. pipes ( external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges:Above 40 mm nominal bore

50

-

-

... More
15.48 : Taking out C.I cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually / by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials with 50 metres lead as per direction of Engineer -in- Charge.

5

-

-

... More
15.49 : Taking out C.I cover with frame from R C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually / by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer - in-Charge.

5

-

-

... More
15.59 : Dismantling of flexible pavement ( bituminous courses ) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of Engineer-in-charge.

50

-

-

... More
od301767/2023_2024 : Dismantling of Cement Concrete block masonary work of any size & shape, at all levels, removal of debris, disposing the same away from the site, loading and unloading, making the surface good etc. complete. Rate shall include for disposing the unserviceable materials/debris away from the site by mechanical means including loading, unloading, clearing the site etc. complete, as directed.

10.8

-

-

... More
od301768/2023_2024 : Dismantling of wooden, gypsum, ACP cladding/ lining of walls and partitions including stacking of serviceable material in the stockyard of Infopark and disposal of debris to approved dumping yards for all lead and lift etc complete as per directions of Engineer-in-charge<br>

10

-

-

... More
4.2.3 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

5.04

-

-

... More
4.3.2 : Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.

19.32

-

-

... More
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

66.59

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

11.45

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

5827.5

-

-

... More
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).

6545

-

-

... More
26.29.1 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter

50

-

-

... More
26.29.2 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars above 12 mm diameter

50

-

-

... More
26.30.1 : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.Upto and including 12mm dia.

70

-

-

... More
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

277.2

-

-

... More
26.37 : Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge.

10

-

-

... More
26.80.1 : Providing & Grouting of dowel tubes / Shear keys / Joints of precast members with M-60 grade cementitious grout (Non Shrink) of approved make by suitable means ( Free flowing /pump),curing etc. Complete as per directions of Engineerin-charge. (The payment shall be made on the basis of actual weight of approved grout injected.)Stirrer mixed cementitious grout (non shrink) of approved make in dowel tubes / Shear keys / Joints of precast members.

50

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

408.77

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

49.9

-

-

... More
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

327.62

-

-

... More
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

4345.32

-

-

... More
13.78 : Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite / perite respectively conforming to IS : 2547 ( Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.

2122.68

-

-

... More
od308393/2023_2024 : Forming groove of uniform size from 12x12 mm and upto 25 x 15 mm in the top layer of plastered surface as per approved pattern, including providing and fixing aluminium channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer -in-Charge.

1516.2

-

-

... More
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate

248.57

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

252

-

-

... More
11.5 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

252

-

-

... More
od301812/2023_2024 : Providing 100 mm thick cement concrete flooring with concrete hardener topping, under layer 88 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, etc. complete. Cement concrete shall be ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability. The concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques and as per direction of the Engineer - in - charge.

3780

-

-

... More
11.54.1 : Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on the G.I. Base plate of size 100mmx100mmx3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5mm welded with GI fully threaded stud 16 mm outer diameter with two GI check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Guages: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with light weight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm. The panel is to withstand a Concentrated Load of 363 Kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50 kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.300 mm Finished Floor Height (FFH).

112

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

100

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

252

-

-

... More
od301775/2023_2024 : Providing and laying modular carpet of approved make made with 100% nylon 6.6 Multilevel textured loop pile, manufactured using digital injection / solution dyeing process, with protective treatment stainsmart (stain repel/stain resist/stain release), anti microbial alphasan, with PVC free PU cushion backing or recyclable/ recycled backing as per manufacturer's specification, nominal total thickness of minimum 6.8 mm (pile height minimum 2.75 mm) , Minimum Density of 95 Oz/ Sq.yd. Carpet to meet ARR - Severe Rating as per CRI TM 101 . Material shall be CRI LEED ceertified , including fixing with green adhesive of approved make, all complete as per manufacturer's specifications and direction of Engineer in Charge. Size of the carpet shall be in accordance with approved sample.

3360

-

-

... More
od301776/2023_2024 : Providing and laying vitrified floor tiles of size 1800 x 1200 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement: 4 coarse sand) and grouting the joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) including filling /grouting and finishing complete as per direction of Engineer-in-charge. The tiles must be cut with zero chipping diamond cutter. Laying of tiles to be done with notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.

478.8

-

-

... More
od301777/2023_2024 : Providing and laying vitrified floor tiles of size 1000 x 1000 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement: 4 coarse sand) and grouting the joints of 3 mm width, using epoxy grout mix 0,70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) including filling /grouting and finishing complete as per direction of Engineer-in-charge. The tiles must be cut with zero chipping diamond cutter. Laying of tiles to be done with notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.

100

-

-

... More
od301778/2023_2024 : Providing and laying vitrified floor tiles of size 600 x 600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) including filling /grouting and finishing complete as per direction of Engineer-in-charge. The tiles must be cut with zero chipping diamond cutter. Laying of tiles to be done with notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.

452.48

-

-

... More
od308425/2023_2024 : Providing and fixing Vitrified full body tiles of size 1200x600 mm conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

653.52

-

-

... More
od301796/2023_2024 : Providing and fixing Single glazed partitions using Saint Gobain/ Kubik Lite/ Dormakaba System 45 Frames or any equivalent brand with 12mm thick toughened glass to a height of maximum 3 m that shall be able to provide a sound reduction of 36.7 dB. The glass panels shall be supported by Aluminium WCP Profiles of 25x45mm having 2 mm gauge thickness on all 4 sides of the Glass partition perimeter. Stickon profiles to be provided at a spacing of 600 mm c/c. Glass-to-glass butt joints shall be provided with Suitable junction profiles are to be used at glass-to-glass joints such as H Junction profile to be used at all Glass to Glass vertical joints, 90 Deg L Junction Profiles and T Junction profiles necessary as per design. Finishes of all aluminium frame components shall be Anodized Finished (20 microns) of approved colour. At the location of doors, End Profile frame, suitable for stile/flush door, of size 45 x 50 mm shall be provided around the door two vertical upto false ceiling and horizontal at door top. Adjacent to the door frame, suitable service profile to be provided for installing the access control system as per requirement. Rate shall include for providing and fixing necessary support arrangement to ensure proper anchorage / fixing to the ceiling/partition to get sufficient rigidity (to the required level). Rate shall include for transport charges, handling, loading and unloading, installation of glass and protecting the module and glass till handing over, testing, commissioning all necessary hardware, Structural supports, scaffolding, wastage, etc. complete and all as per manufacturers specifications as directed. The vendor has to prepare the shop drawing for approval of Engineer-in-charge. Note : Only the actual area shall be considered for measurement and payment

1084.47

-

-

... More
od302888/2023_2024 : Providing and fixing partition above glass partitions, made out of aluminium box frame using extruded sections of size 50 x 25 mm - 1.5mm thick at 600mm c/c in both direction covered with panelling on both sides with 12.5 mm thick gypsum plasterboard having high impact resistance, loading capacity, fire & acoustic performance made out of Calcium sulphate dihydrate encased in paper liners, with glass fibers and other additives complying to IS 2095 Part 1:2011 standards (Gyproc Habito board or equivalent),including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and insulation to be provided with Resin Bonded rock wool conforming to IS: 8183, having density 48 Kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene Bags fixed to boards with screw, rawl plug & washers and held and in position by criss crossing GI wire as per directions of Engineer-in-charge. Rate shall include cost for necessary hardwares and shall include for forming a panelling to any shape including circular profile etc. complete. Actual seen surface area will be measured and paid.

542.23

-

-

... More
od302911/2023_2024 : Providing and fixing 98 mm overall thick partition using 12.5 mm thick gypsum plasterboard having high impact resistance, loading capacity, fire & acoustic performance made out of Calcium sulphate dihydrate encased in paper liners, with glass fibers and other additives complying to IS 2095 Part 1:2011 standards (Gyproc Habito board or equivalent), including frame work made of special sections power pressed/ roll form G.I. sheet with Zinc coating of 120/150 gsm , consisting of floor and ceiling channel 32x72x32x0.5 mm size 72 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diameter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 34x70x36x0.5 mm 70mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, noggin channel 40x70x40x0.5mm as required, insulation to be provided with Resin Bonded rock wool conforming to IS: 8183, having density 48 Kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene Bags fixed to boards with screw, rawl plug & washers and held and in position by criss crossing GI wire and fixing of gypsum board on both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre, with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher, and two coats of primer suitable for board as per manufacturer's specification, etc complete as per direction of Engineer-in-charge. The junction of the partition with masonry & all penetration through the partition has to be treated with Hilti/Pyroplex fire and acoustic sealant. Note: Area from FFL to bottom of false ceiling height only will be measured for payment.

1322.1

-

-

... More
od301848/2023_2024 : Supply and fixing of Glazed Stile door with Saint Gobain/ Kubik / Dormakaba system make or equivalent brand with 12mm toughened glass. Aluminium stile to be formed out of 70x35 mm horizontal and vertical door profile frame with clips and seals with intermediate stick on profiles as provided in glazed partition. The Stile profiles and hardware shall be anodized finish of same colour as partition profiles. Required door hardwares such as 4 nos of flush hinges of required size with screws and in black finish, cam action concealed door closer with hold open unit, half moon door stopper, square shaped black pull handle and narrow stile dead lock package are to provided and fixed along with necessary seals all around the door frame. The profile manufacturer to supply all the necessary clips, seals and fixing accessories for the system etc complete. All Profiles to be approx. 2 mm Gauge thickness excluding 20 Micron of Anodizing. The work shall be undertaken as per approval and directions of Engineer-in-charge

213.84

-

-

... More
od301850/2023_2024 : Providing and fixing in position flush doors with door frame using second class teak wood, wrought framed, melamine polished and fixed in position with hold fast lugs or with dash fasteners of required dia & length and factory finished ISI marked flush door shutters 40 mm thick conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters, providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters and laminated with 1 mm thick satin finish decorative laminate sheet, vision panel to be provided with bevelled glass 8 mm thick with required lipping including fixing with accessories such as ISI marked stainless steel butt hinges with necessary screws and other accessories such as SS tubular door handle 600 mm long, brass mortise latch and lock with 6 levers without pair of handles, concealed door closer with sliding arm, hanging type floor door stopper etc complete as per directions of Engineer-in-charge

23.76

-

-

... More
od301827/2023_2024 : Supplying and installation of steel Fire door with Fire Rating of 120 minutes rating as per manufacturers specification and tested in accordance with IS 3614 Part-2 BS 476 Part-22 . (a) Fire resistant door frame made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) of section 100x57 mm having built in single rebate duly filled with vermiculate based concrete mix, suitable for mounting door shutters, kerf frame fitted with intumescent fire seal strip of size 10x4 mm (minimum) allround the frame and fixing with dash fastener of approved size and make, reinforcement pads for fixing of door closer at appropriate location, factory finished pre-punched cut-outs to receive specific hardware and ironmongery, requisite mortar guard, hinge plates predrilled to receive hinges for screw mounted fixing, minimum of five anchors per jamb suitable for adjoining wall construction, etc as per site conditions, Grouting the frame with cement slurry including providing necessary Hilti make Intumescent Joint Filler - code no CP 606 or Wacker - R - Glazing & Metal (Elastomeric / Intumescent) in the gaps between Wall & Frame to the required thickness and to be applied by using suitable Dispenser tool etc complete as per manufacture's specification. (b) Fire door shutters to be manufactured from 16 SWG G.I. sheets(zinc coating not less than 120 gm/sqm) to be press formed to 50 mm thick double skin hollow door with lock seam joints at stile edges with a bending radius of 1.4 mm, with internal reinforcement at top, bottom and stile edges made out of 16 SWG G.I. sheet duly filled FR insulation material (96 kg/cum density), the door face should not have visible screws or fasteners on either face and the doors to have pre-drilled hinge plates with hinged guard covers, fixing with necessary stainless steel ball bearing hinges in the factory prepared pre-punched cut-outs and reinforcements, locks with concealed lock box with lock fixing brackets with pre-tapped holes, door closer reinforcement pads at appropriate location (c) Vision panel of size 200x600 mm using 6 mm clear fire resistant glass fixed with GI beading of appropriate size, fire resistant sealant, beading, screws from inside etc. The rate shall also include provision for finishing with zinc phosphate storing primer and powder coated in not less than 30 micron in desired shade as per NBC 2016, IS 16231 (Part 3):2016. The rate shall also include provision for required fittings such as door closers, panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete. Rate shall be inclusive of making required provisions for fixing access control unit. Warranty: 5 years Maunfacturer's certificate to be submitted.

50.4

-

-

... More
od301824/2023_2024 : Providing and fixing fire resistant door having 120 minutes fire rating with frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m2) suitable for mounting 120 min Fire Rated Door Shutters , filled with Mineral wool Insulation having density min 96Kg/m2, fixing with G.I. Anchor fasteners (5 each on vertical style & 3 on horizontal style of size M10 x 80 ) in the opening along with Factory made templates for fixing hinges, door closers etc, fixing 60 mm thick fire resistant door shutters of 120 min fire rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make. The door frame and shutter shall be finished with approved fire resistant primer and powder coated in not less than 30 micron in desired shade as per NBC 2016, IS 16231 (Part 3):2016. The rate shall also include provision for required fittings such as lock and handle of reputed brand and manufacture to be approved by the Engineer -incharge, all complete.

12.6

-

-

... More
od309123/2023_2024 : Design, supply and installation of movable frameless folding glass panel partition using 10 mm thick toughened glass, with hinges incorporated on top and bottom profile with roller wheels coated with nylon to ensure noiseless and easy operation, frames to be anodised in any RAL finishes as per directions of Engineer-in-charge

54.77

-

-

... More
od303146/2023_2024 : Providing and fixing display shelf made with MS frames and WPC boards as per the pattern in the drawings using factory made 18 mm thick single extruded WPC (Wood Polymer Composite) boards comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant, shelf to have boxes made of WPC boards laminated with PVC foil of minimum 14 microns thickness of approved design pasted with hot melt adhesive for placing plants and shelves and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer and two coats of synthetic enamel, grid made as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge.

36

-

-

... More
od308349/2023_2024 : Providing and fixing decorative partitions with frame work made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing as per directions of Engineer-in-charge, with necessary welding at junctions and fixing the frame to wall/ceiling/floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for fixing of glass/ ceramic writing board/ MDF/ plywood, electrical conduits, switch boards etc., including providing with two coats of approved steel primer and two coats of synthetic enamel paint etc. complete, all as per direction of Engineer-in- charge.

77.7

-

-

... More
od308333/2023_2024 : Providing and fixing decorative MDF designer embossed sheets 2.3 mm thick Century<br>Prowud ARTZ make or equivalent for plain lining / cladding with necessary screws/ adhesive etc complete as<br>pe directions of Engineer-in-charge<br>

5

-

-

... More
od308335/2023_2024 : Providing and fixing, in position concealed G.I. section for wall paneling using 8 mm thick Cement bonded wood particle board as per IS:14276 of decorative finish as per approval of Engineer- in-charge fixed on the 'W' profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the 'W' profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing and directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish.

5

-

-

... More
od308336/2023_2024 : Providing and fixing display floating shelves 200 mm depth and 40 mm thick made with BWP plywood and covered with 1 mm thick laminate sheet of approved design by Engineer-in -charge and fixing to wall using floating shelf brackets etc. all complete as per direction of Engineer-In- Charge.

50

-

-

... More
od308337/2023_2024 : Providing and fixing panelling (wall, column etc), made with single layer 12 mm thick fire retardant plywood fixed over framework of Aluminium extruded sections of size 50x25mmx1.5mm thick in both horizontal and vertical direction at 600 mm c/c spacing. The plywood shall be fixed up to 75mm above false ceiling and open edges with walls to be sealed with plywood. The rate shall include cost of all necessary hardware's etc; as required for completing the works. Note: Actual seen surface area.(i.e) from FFL to bottom of false ceiling height will be measured and paid.

5

-

-

... More
od308338/2023_2024 : Providing and fixing PVC sheet Century Starke/Thomson Multi wood board or equivalent make panelling 12 mm thick, to frame, backing or studding with screws etc. complete, aluminium box frame using extruded sections of size 50 x 25 mm - 1.5mm thick at 600mm c/c in both direction up to 75mm above false ceiling as per directions of Engineer-in-charge. Rate shall include cost for necessary hardwares and shall include for forming a paneling to any shape including circular profile etc. complete. Actual seen surface area.(i.e) from FFL to bottom of false ceiling height will be measured and paid

5

-

-

... More
od308339/2023_2024 : Providing and fixing plain lining with Prelaminated particle board with one side decorative and other side balancing lamination, flat pressed 3 layer & graded (medium density) Grade i, Type II conforming to IS : 12823 (exterior grade) 12 mm thick and fixed on existing frame work with necessary screws/nuts/ bolts/nails, etc, complete as per direction of Engineer-in-charge

5

-

-

... More
od308340/2023_2024 : Providing and fixing in wall lining fluted MDF board 12 mm thick including fixing arrangement with screws/adhesive etc. complete as per directions of Engineer-in-charge

5

-

-

... More
od308341/2023_2024 : Providing and fixing in wall lining Thomson woodex or equivalent WPC fluted panels, including fixing on existing surface or frame work as per manufacturer's specification etc. complete and as per directions of Engineer-in-charge

126

-

-

... More
od308342/2023_2024 : Providing & Fixing decorative textured high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.<br>1.0 mm thick

10

-

-

... More
od308343/2023_2024 : Providing and fixing decorative partition using 25 mm thick BWR plywood finished with 1.0 mm thick laminate of approved colour and shade and fixing of 10 mm thick toughened glass cut to size and shape as per design etc complete and as per directions of Engineer-in-charge

42

-

-

... More
od308424/2023_2024 : Providing and fixing Pelmet for concealing the pull-down projector screens and blinds. The pelmet shall be made of 19mm thick BWR. ply finished with enamel paint of approved shade. It shall be of 'U' shape of size 150 x 150 mm and its bottom level shall be fixed flush with the adjoining false ceiling level so as to recess the pelmet. Rate to include all hardware and supports for sufficient rigidity and to receive the false ceiling perimeter channels.

599

-

-

... More
od301803/2023_2024 : Providing and fixing of PVC ceiling of VOX Infratop innovative ceiling system of approved shade and colour (nature or unicolor as per design) with required ceiling channels and all accessories as per requirement of the manufacturer. Necessary cut outs for lights, detectors, speakers, camera, etc to be provided as per requirement at site. Required trap doors made with aluminium frames and panels along with click lock, guard hook, safety rope etc of required size shall be provided as per requirement at site. The rates quoted shall be all inclusive for providing the ceiling system along with all accessories, cut outs, trap doors and for installation by the manufacturers authorised team. The work shall be executed as per approval and directions of Engineer-in-charge. Manufacturer’s warranty certificate to be submitted for 10 years.

100

-

-

... More
od301804/2023_2024 : Providing and fixing false ceiling at all heights with square lay in GI prepainted Open cell ceiling system with panels of Size 595x595 mm 38 mm height and cell size 150x150 mm of approved colour as per site requirement (black/white), design and patterns, in true horizontal level suspended on interlocking metal powder coated of matching colour T15-Grid of hot dipped galvanised iron section of 0.40 mm thick profile, rotary stitched double webbed, comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded anchor rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.

396

-

-

... More
od301805/2023_2024 : Providing and fixing false ceiling using 12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1 at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120-150 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, providing vertical edges for a depth of 100 mm at junctions of different type of ceilings, concealed cove lighting etc as per design including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint, applying plaster of paris putty to prepare even and smooth, two coats of primer suitable for board, painting two or more coats with premium acrylic emulsion paint having VOC content less than 50 grams/litre of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour, all as per manufacturer's specification and also including the cost of making openings for light fittings, cove lighting, profile lighting, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge Note: The plan area only will be measured for payment

200

-

-

... More
od301806/2023_2024 : :Providing and fixing false ceiling using 12.5 mm thick tapered edge gypsum moisture resistant board conforming to IS : 2095-Part 1 at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120-150 gms/ sqm both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, providing vertical edges for a depth of 100 mm at junctions of different type of ceilings, concealed cove lighting etc as per design including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint, applying plaster of paris putty to prepare even and smooth, two coats of primer suitable for board, painting two or more coats with premium acrylic emulsion paint having VOC content less than 50 grams/litre of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour, all as per manufacturer's specification and also including the cost of making openings for light fittings, cove lighting, profile lighting, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge Note: The plan area only will be measured for payment

248.57

-

-

... More
od301807/2023_2024 : Providing ceiling trap door/access panel in false ceiling of 1200 mm x 600 mm size made from aluminium powder coated frame and MR gypsum board with click lock, guard hook, safety rope, brush sealing strip etc. The rate shall include for finished with two coats of premium acrylic emulsion paint over a coat of primer and putty as directed by Engineer-in-charge

5

-

-

... More
od301808/2023_2024 : Providing ceiling trap door/access panel in false ceiling of 600 mm x 600 mm size made from aluminium powder coated frame and MR gypsum board with click lock, guard hook, safety rope, brush sealing strip etc. The rate shall include for finished with two coats of premium acrylic emulsion paint over a coat of primer and putty as directed by Engineer-in-charge

5

-

-

... More
od301809/2023_2024 : Providing ceiling trap door/access panel in false ceiling of 300 mm x 300 mm size made from aluminium powder coated frame and MR gypsum board with click lock, guard hook, safety rope, brush sealing strip etc. The rate shall include for finished with two coats of premium acrylic emulsion paint over a coat of primer and putty as directed by Engineer-in-charge

5

-

-

... More
od301810/2023_2024 : Providing and fixing tiled false ceiling at all heights with GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 1195x595 mm and 0.5mm thick with 8 mm dr op; made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece , to be laid in true horizontal level, suspended on Silhouette profile, rotary stitched double webbed white with 6 mm reveal profile (white/black) inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm Including both sides) comprising of main-T runners of size 15x38 mm of length 3000 mm, cross - T of size 15x38 mm of length 1200 mm and secondary intermediate cross-T of size 15x38 mm of length 600mm to form grid module of size 1200 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.

378

-

-

... More
od301811/2023_2024 : :Providing and fixing tiled false ceiling of GI Metal Ceiling Lay in perforated Tegular edge global white/black/wooden colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm dr op; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece., in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile, rotary stitched double webbed with 6mm reveal profile (colour as per site condition and direction of EIC), comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and Lshape level adjuster of size 85x25x2 mm.Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.

90.72

-

-

... More
od303045/2023_2024 : Acoustic baffle Wooden ceiling-Anutone Salon Sonator Wave Perfs 400x1200x25mm thk, Square edge.Supply & installation of Anutone Salon Sonator Wave Perfs, made of pinewood E1 grade fiberboard, with Ranurado 6R32| Cuadrado 25/50 | Circulo 25/50 perforations with black acoustical fleece sandwiched inbetween,melamine finish, 5-test fire retardant grade, size 400x1200x25mm, square edge, volume density of base board 750Kg/m3, weight 19Kgs/m2,suspended from the soffit slab to desired height and span distance by using Anutone Strut U-ClipHD25 Kit.Anutone Strut U-ClipHD25 is first fastened to Sonator Wave using supplied sleeve fasteners at 50-100mm from edge and 500-600mm centres. Strut U-ClipHD25 is then connected to the Kit-supplied Anchor wire with Levelling hook. <br>Salon Sonator Wave Perfs are then suspended using Anchor Bolt, Soffit Cleat and S-hook from the soffit slab and levelled into designed position. (Anchor bolts, Soffit Cleat and S-hook not by Anutone). Technical Parameters:• Fire (Class) – 1 & P<br>• Thermal conductivity (W/mk)– na<br>• Climate (°C, RH) – 50, 70<br>• Light reflectance (%) – Colour Dependant<br>• Green (VOC, RC %) – Low, 25

20.16

-

-

... More
od303046/2023_2024 : Providing and fixing Acoustic baffle Wooden screen ceiling of approved item as per engineer-in-charge.Anutone Salon Sonator Duo 400x1200x16mm thk, Square edge.Supply & installation of Anutone Sonator duo, made of pinewood E1 grade fiberboard, wooden plain panel, melamine finish, 5-test fire retardant grade, size 400x1200x16mm, square edge, volume density of base board 750Kg/m3, weight 12Kgs/m2,suspended from the soffit slab to desired height and span distance by using Anutone Strut U-ClipHD15 Kit.Anutone Strut U-ClipHD15 is first fastened to Sonator Duo using supplied sleeve fasteners at 50-100mm from edge and 500-600mm centres. Strut U-ClipHD15 is then connected to the Kit-supplied Anchor wire with Levelling hook. Salon Sonator Duo are then suspended using Anchor Bolt, Soffit Cleat and S-hook from the soffit slab and levelled into designed position. (Anchor bolts, Soffit Cleat and S-hook not by Anutone). Technical Parameters :• Fire (Class) – 1 & P• Thermal conductivity (W/mk)– na• Climate (°C, RH) – 50, 70• Light reflectance (%) – Colour Dependant• Green (VOC, RC %) – Low, 25

20.16

-

-

... More
od303047/2023_2024 : Providing & fixing suspended ceiling comprising of Armstrong make or equivalent Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5 in triangular pattern using baffle blades of size 25x150x3600mm in powder coated to Woodgrain finish – Red Oak or Cherry. The baffle blade shall be suspended using Slotted U-profile of 20 x 30 x 3700 mm (thk – 1.5 mm) having slots in module of 25mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps. Installation of U-Grid: The U profile to be suspended at every 1200mm centre to centre using 6mm threaded rod from the structural soffit using U-profile hanger. Installation of Parallel Armstrong Baffles: Locate the slot for Baffle Hangers in U Profile section at 1200mm centers. Hangers are fixed into the slot, then rotated 90° and fixed into position by tightening the grub screw. Baffle to be lifted into position and hangers engage over lip of U-Grid Channel. Each Hanger to be secured into position by fixing the Locking Clip. When doing continuous installation, Baffles blades are to be connected at ends with Baffle Joiner, which are fixed into the top and bottom slots of the Baffle closed profile for alignment only. The bottom Joiner to be located first and fastened on one side only. The top Joiner to be fitted then and secured with grub screws on one side. Then the two Baffle sections shall be joined and the top Joiner is screw fastened on the 2nd Baffle profile. End Caps to be located by pushing the End Cap tongues into open Baffle slots. Installation of Non-Parallel Armstrong Baffles: The Non-parallel Baffles shall be measured and cut at specified angles, using appropriate machinery. Hook-Over end caps shall then be connected at the two ends of each baffles. This assemble shall be hooked and placed on top of the parallel baffles. The baffles shall then fixed into position using appropriate fasteners (as guided by the shop drawings). Installation should be carried out as per Armstrong recommended procedure. The Baffle along with suspension system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The supply shall be backed by a Manufacturing Test Certificate.

180

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

808.08

-

-

... More
13.26 : Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

5533.8

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

5

-

-

... More
13.85.3 : Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre

5

-

-

... More
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

5

-

-

... More
13.109.1 : Finishing walls with water proofing cement paint of required shade :Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.

5

-

-

... More
13.48A.1 : Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

5

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

5

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

5

-

-

... More
od308398/2023_2024 : Painting walls/partitions/ceiling with two or more coats with premium acrylic emulsion paint having VOC content less than 50 grams / litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour after applying priming coats with suitable primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content and including cost of scaffolding or form work as necessary etc. complete as per directions of Engineer-in-charge

12078.8

-

-

... More
od308399/2023_2024 : Painting wood work/MDF surface with PU paint of of approved make in required shade in high gloss/satin/matt finish as per requirement of Engineer-in-charge. Two or more coats of PU paint to be applied over two undercoats of primer over insulator coat as per requirement of manufacturer’s specification etc all complete as per directions of Engineer-in-charge

10

-

-

... More
od308403/2023_2024 : Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below1. The surface to be polished is rubbed with sand paper 80/120 no, and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.<br>3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler Coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.<br>4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in- Charge.(Final coat to be done in 1 or 2 layers without gap of time.)

1

-

-

... More
od308405/2023_2024 : Providing and applying texture paint using lime based microporous decorative coating and motif based stencils to achieve final design, texture and colour as per the pattern approved by Engineer-in-charge in Asian paints Royale Play Lithos range or equivalent after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, etc complete as the direction of Engineer-in-Charge. Material shall be as per the manufacturer's specification and application to be done by approved team of manufacturer. Rate to include cost of sanding, primer, putty, base coat, top coat all paints, glue, men, material, tools and tackles, scaffolding etc. complete as required

20

-

-

... More
od308406/2023_2024 : Decorative wall painting by commissioning an artist to paint a mural art/graffiti work on internal walls including cost of all materials, labour, scaffolding, accessories etc complete as per directions of Engineer-in-charge

84

-

-

... More
od308407/2023_2024 : Providing and fixing pin up board 9 mm thick soft board wrapped with 100% polyesterfabric with 375 grams/metre weight and fire retardant having flammability conforming to BS EN 1021-1: 1994(Cigarette) BS 7176: 1995 Low Hazard (make: Response Fabrics or equivalent) to be fixed with aluminiumedge profile framework and all accessories complete as per directions of Engineer-in-charge

6.48

-

-

... More
od308408/2023_2024 : Supply & fixing of 9 mm thick PET Acoustic Panels with grooves in approved pattern ofapproved make on Partition / Masonry wall surface and as directed using appropriate adhesive as permanufacturer instructions and edging profiles of natural anodised aluminium edging with counter sunkholes punched every 300mm. The rate shall be inclusive of preparing the base surface, all wastages, etc.Note : Only the actual installed area shall be measured for payment

59.28

-

-

... More
od308526/2023_2024 : Providing & fixing 6 mm thick lacquered glass of (Saint Gobain or app. equivalent) and of approved shade as per pattern and details given in drawing, fixed with compatible SGG Glassmate Ultrafix - Neutral Alkoxy based Silicone having Shear Bond Strength (Dry, 24 hours), greater than 450 kpa and tack free time of 10 to 30 mins compatible for installation of mirror and lacquered glass / SGG Glassmate Mirror mounting tape MIRROR MOUNTING TAPE - Foam based double sided adhesive tape for instantaneous<br>adhesion, compatible with mirror and lacquered glass having Shear bond strength (Dry, 15 mins) of 250 to 350 kpa) on a perfectly leveled surface. The contractor should submit test reports for back painted glass from manufacturer - High humidity Resistance (conforms to BS EN 1036 1999); Color fastness ISO 105B02 standard & Mechanical Resistance ISO 7784 ( Taber Abrasion test ) ISO 2409 ( Cross Hatch Test ) standard The manufactured back painted glass should be environmentally friendly (no lead, no arsenic, no copper, no formaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive<br>strength (1000 MPa) & tensile strength (40 MPa),same as float glass, etc all complete as directed and to the satisfaction of the Engineer-in-charge. At junctions with other materials aluminium profiles to be considered. Rate to include all wastages, necessary supports & backing to ensure rigidity, levels & plumb, etc complete.

64.26

-

-

... More
od308409/2023_2024 : Supply and installation of Metal wall art décor of approved design by Engineer-incharge (Basic cost - Rs.4,000.00)

7

-

-

... More
od308410/2023_2024 : Providing and fixing of Room Nomenclature Signages in Brass plate with brushed metal finish with vinyl cut lettering of approved shade and of size 400 x 100 mm. The brass signage shall be pasted using double-sided tape of 3M make on the Glass doors/ Flush doors.

90

-

-

... More
od308411/2023_2024 : Supply and installation of Display signage board in acrylic sheet of sufficient thickness of size 1.20x1.50m fixed with suitable method to wall and fixing acrylic cut logos and brass name plates with vinyl lettering etc complete as per directions of Engineer-in-charge

7

-

-

... More
od308412/2023_2024 : Providing and fixing of Room Nomenclature Signages Brass make with brush metal finish with acid etched signs of approved shade and of size 125 x 125 mm for Toilets. The brass signage shall be pasted using double-sided tape of 3M make on the Flush doors etc. complete as per directions of Engineer-in-charge.

21

-

-

... More
od308413/2023_2024 : Providing and fixing of Conference Room signage with metal frames and Brass nameplates with open frame slider design to display the availability of any event. Signage to be brass make with brush metal finish with vinyl lettering signs of approved shade and of size 400 x 100 mm. The brass signage shall be pasted using double-sided tape of 3M make on the Flush doors etc. complete as per directions of Engineer-in-charge.

1

-

-

... More
od308414/2023_2024 : Providing and Fixing of Anodised Aluminium Recessed Pen Tray of Kubik make : Model No. KS-PT-001-AL or app. equivalent in natural anodized finish, of 450mm length and as directed. Rate shall be inclusive of the corresponding end caps : Model No. KS-EC-10, all hardware, wastages, partition modifications to accommodate the recessed fixture, etc complete and as directed.

61

-

-

... More
od308415/2023_2024 : :Providing and fixing etching to glass panels using 3M film (Code No. 7725 with 5 years warranty) of approved color printed graphics as directed. Rate shall be inclusive of all wastages, etc.Note : Only the actual installed area shall be measured for payment.

5

-

-

... More
od308416/2023_2024 : Providing and fixing etching to glass panels using 3M frosted film (sparkling type) of Code No. 7725 with 15 years warranty, as per required pattern and design and as directed. Rate shall be inclusive of all wastages, etc. Note : Only the actual installed area shall be measured for payment.

5

-

-

... More
od308417/2023_2024 : Supply and installation of sun control window film which offers outstanding heat reduction 3M make or equivalent as per directions of Engineer-in-charge.

5

-

-

... More
od308418/2023_2024 : Providing and fixing of Vinyl Graphics using 3M film (Code No. IJ180C with 5 years warranty) as per approved design and at specified locations as directed by Engineer-in-charge. The rate shall be inclusive of preparing the base surface to smooth finish as per the manufacturer's/ vendor's requirement, all complete and as directed. Rate shall be inclusive of all wastages, etc. Note : Only the actual installed area shall be measured for payment.

5

-

-

... More
od308419/2023_2024 : Providing and laying of premium quality Wallpaper of approved make and design over partition / panelling / wall surfaces. Rate to include preparation of base surface to smooth finish as per manufacturer's requirement, all complete and as directed. Rate shall be inclusive of all wastages, etc. The wallpaper shall be moisture resistant, durable, long lasting, energy saving, thermal insulating with a warranty of 1 year. Note : Only the actual installed area shall be measured for payment. Note : Basic rate of Wallpaper = Rs.85.00 per sq.ft.

5

-

-

... More
od308420/2023_2024 : Supply and installation of paintable decorative fibreglass wall covering with a homogeneous film of glue activated by water of approved make and brand on walls and ceilings as per directions of Engineer-in-charge. The product shall have fabric weight between 130 GSM to 390 GSM, PVC Free, Environment Friendly, Euroclass B-s1, d0 fire resistance certification (EN 13501-1) and Product Class II / Class III Oeko-tex standard 100 certified

180

-

-

... More
od308423/2023_2024 : Providing and fixing of Honeycomb blinds made of Original Non-woven honeycomb shades having soft fabric appearance and high energy-efficient fabric with high tear strength constructed out of Anti static, resilient, colour fast & sanitized treat 100% spun bonded non-woven polyester fiber & precision manufactured to form a hexagonal shaped duette pleat . Pleat dimension ¾”Honeycomb within a Honeycomb” with 3 distinct air pockets for superior energy efficiency and increased insulation. Shadings are duotone, with neutral tone facing the exterior and color facing the interior .Being a Low shading co-efficient will have following Comfort rating & solar optical properties. Fixing with easy drive operating system having HEADRAIL measuring 49.68 wide and 36.66mm deep & thick 1.27mm extruded from 6063 T6 alu. alloy & shall be powder coated to a smooth finish with a thickness of 40 microns. All cords & cord holes shall be fully concealed inside the fabric structure. As each of the hexagonal cells is formed individually, pleats operate independent of each other providing superior pleat retention & structure strength. INSTALLATION BRACKETS shall be of high tension spring steel suitable for overhead & wall mounting 30mm Duette Hartford mounting bracket. POLYESTER CORD shall be 0.9mm in diameter & of woven hollow core. ENDCAP shall be molded acrylic color matched to the head & bottom rails. BOTTOM RAIL shall be a single channel section, measuring 30mm wide and 12.5mm deep & thickness 1-1.2mm extruded from 5005 H-16 alu. alloy & shall be powder coated with a smooth finish to a thickness of 15-25 microns. HOLD-DOWN BRACKET (optional) shall be molded in clear acrylic. It incorporates a pin for engagement with the bottom rail end-cap. It shall be suitable for sill, face or side facing. CORD.EQUILISER shall be injection molded from impact modified acrylic with a high flexural modulus. Approved make: Hunter Douglas, Phifer, Vista or equivalent.<br><br> as per Manufacturer's instruction of approved make (Hunter Douglas Roller shades/ PHIFER / VISTA or equivalent) as per manufacturer's specification etc complete as per directions of Engineer-in-charge .

21.6

-

-

... More
od308618/2023_2024 : Supply and installation of VISTA Roller Blinds blackout Series‐ Venice/ Volga Opaque or equivalent make with Control unit made of high strength reinforced plastic with clutch of wrap spring design, High carbon steel springs provided to transmit motion from driving to driven members of clutch mechanism., Clutch operated directionally by the use of endless beaded chain, Idler of high strength reinforced plastic, consisting of a centre shaft mounted on the bracket by using a plastic lock, metal sleeve inside the plastic lock provides bearing surface for the centre shaft, which rotates freely, providing smooth, quiet and long wearing operation, Head rail of aluminium extruded rail Powder coated in white, Control unit and Idler are mounted on the Head rail with powder coated M.S. brackets, Roller tube anodized extruded tube of high strength alloy, Control unit and Idler are fixed to the either ends of the tube, fabric of the blind is fitted to the tube with heavy duty adhesive tape, Bottom rail of aluminium extruded rail with a groove for fixing the fabric and power coated in white, fixed to the bottom of the fabric to keep the fabric in tension and straight using plastic ins ert, ABS end caps , Operating chain made of 4.5mm plastic beads moulded on 2.2mm thick polyester chord with pitch of the beads 6mm, Fixing brackets & clamps to fix the blind to the wall or ceiling. 'L' bracket made of mild steel and zinc plated, the clamp shall be made up of spring steel of thickness O.7mm and zinc plated, Roller tube of Aluminum alloy Extruded grooved tube anodized of size 32mm O.D. and weight ‐ 0.27 kg/mtr Size‐ 38mm‐ O.D.; weight ‐ 0.38 kg/mtr Size‐ 50mm‐ O.D.; weight ‐ 0.60 kg/mtr Alloy & temp‐ 6063‐T6 Fabric is fitted on the tube with double sided tape. Bottom Rail: Extruded Aluminum grooved section‐ powder coated in white Size: 21mm O.D. Alloy‐HE9WP Weight‐0.28 Kg/mtr. Fabric is fitted to the bottom rail with plastic ins ert. Bottom rail end cap‐ made of ABS. Fabric Blackout Polyester, Fabric Thickness 0.6 mm, Fabric Weight +5% 330 GSM, Fabric Width 230 cms, Fire Resistance NFPA 701 AATCC 16‐2003 4.5, Environmental Certification Green Guard Certified, Other Properties Anti Fungal & Anti Bacterial Fabric, etc complete as per directions of Engineer-in-charge .

1554.16

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

63

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

140

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

30

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

10

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

434

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

98

-

-

... More
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

2

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

21

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

7

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

1

-

-

... More
18.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

28

-

-

... More
18.18.3 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore

14

-

-

... More
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore

21

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

1

-

-

... More
od295102/2023_2024 : Supply & flixing of urinal modesty panels for Merino or equivalent make of B-type shape 1200x450mm size with 12 mm compact laminate of approved shade fixed with SS clamps,etc as per manufacturer specification

28

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

35

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

25

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

25

-

-

... More
50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

163

-

-

... More
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

55

-

-

... More
od295240/2023_2024 : Providing & fixing Modular Toilet cubicles of MERINO make of TITAN 12mm STD SERIES or approved Equivalent - complete set including partitions and S.S 304 grade accessories such as Top Rail, Coat hook with Door stopper, Occupancy indicator, Door Knob, & Channel, screws, Adjustable Legs, etc complete and with Rubber strip for the groove in the Pilaster for reducing noise. The cubicle shall be of Pilaster , S.S Leg Floor-mounted type with overhead bracing taking into consideration the stability of the panels. Top bracing shall be connected to the wall for additional support and stability. Wall brackets and corner brackets to be used while assembling the cubicles. In addition, the door should have a self-closing hinge and an indicator slip latch or bolt with a knob outside and 2 coat hooks inside. Note: Contractor to submit shop drawing for approval before start of works. The panels and doors shall be constructed out of 12mm thick Compact Laminate of approved shade. a) Compartment depth ; width: as per the drawings / site measurement b) Door width: 600 mm c) Overall Height : 2100 mm (including bottom gap of 150 mm)<br>

35

-

-

... More
od295288/2023_2024 : Providing and fixing bevelled edge mirror of superior glass 6 mm thick (of approved quality and make) and of required shape and size over 12mm PVC panel of approved make with adhesive, S.S studs of appropriate size and numbers. The mirror shall be provided with polythene sheet backing so as to avoid direct contact of moisture with the silver coating on the mirror rear side. Rate shall be inclusive of all hardware, labour, etc, complete and as per directions of Engineer-in-charge<br>

13.44

-

-

... More
od295413/2023_2024 : Providing, fixing and testing of approved make of 40 mm dia SWR - B- Class PVC pipes and fittings confirming to IS 13592-1992. and fittings (available fittings in market and fabricated fittings ) such as tee, elbow, coupler, etc. conforming to 14735 with latest amendment for soil and waste pipe works in toilets and utility area,etc. Pipes shall be laid in vertical stack and sunken in floors as per approved drawings with proper alignment and gradient as per the drawings with proper split clamp,anchor fastener and 10 mm thread rod supports. Wall cutting shall be done using wall cutting machine, and chasing to be done using electric jack hammer machine. Cutting and chasing with hammer shall not be permitted. Pipes and fittings shall be cleaned with pipe cleaners and joined by approved approved make solvent cement. After laying the pipes, before closing the pipes, gravity test to be conducted and get the approval from the Engineer-in-charge. Chased portions shall be covered with cement mortar. Work includes making required size holes in brick walls wherever necessary and re do same with water proofing components to the entire satisfaction of Engineer-in-charge.etc complete. All the stub outs shall be closed with proper end caps till of installation of sanitary wares and accessories etc. complete.

59.5

-

-

... More
od295414/2023_2024 : Providing and fixing white vitreous urinal of approx. size 280x345x690mm with inlet from back side and pressmatic auto closing concealed urinal flush valve with wall flange, with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required, fixing to wall with suitable brackets all as per manufacturers specification and as per directions of Engineer-in-charge<br>

21

-

-

... More
od295415/2023_2024 : Providing, fixing, testing and commissioning of white vitreous china glazed wall mounted water closet (European type) of approved make with concealed cistern and flushing plate with necessary water connection with integrated angle stop valve production cover for service opening to be cut to the length, WC outlet bend, WC connection set dia 90mm, 2 threaded rods M12 for ceramics fastening,4adjustable fastening brackets, with fastening materials, with actuator plate, complete and the EWC shall be with necessary check nut, stopcock etc., seat and lid, CP brass hinges and rubber buffers, Concealed flushing cistern with fittings supporting bolt /CI / MS brackets. etc. cutting and making good the walls and floors wherever required all complete as per specification and direction of the Engineer-in-charge<br>

35

-

-

... More
od295416/2023_2024 : Providing and fixing walll hung Basin of approved make and colour along with CP fittings of approved make such as 15mm CP brass pressmatic pillar cock , 15mm CP brass angular stop cock, 32mm dia CP brass waste coupling with popup, 32mm dia CP brass bottle trap with extension pipe including necessary supporting brackets, connection tube etc; complete. The supporting brackets, bolt and nuts to be supplied by the contractor. Works including cutting and making good the walls /floor wherever required, including conveyance of all materials to the site, all labour charges, all taxes etc; complete.<br>

7

-

-

... More
od295649/2023_2024 : Providing and fixing PVC floor trap of self cleansing design and CP Anti cockroach floor trap consisting of floor drain hinged grating, inner filter, out filter, rim etc complete, fixed over the floor trap. Work includes cleaning of floor traps before fixing the gratings. While fixing the gratings, flooring should be cut to required size of grating, (not more than 2mm of the grating sizes) using tile cutter etc; complete. The gap should be filled silicon sealant/epoxy grout to match the flooring colour. The colour and shape of the gratings shall be as per the approval from the Engineer-in-charge. To avoid damage of the CP gratings, acid cleaning of flooring shall be done before fixing of gratings.<br>

42

-

-

... More
od295650/2023_2024 : Providing, fixing and testing of approved make of 110 mm dia SWR - B- Class PVC pipes and fittings confirming to IS 13592-1992. and fittings (available fittings in market and fabricated fittings ) such as tee, elbow, coupler, etc. conforming to 14735 with latest amendment for soil and waste pipe works in toilets and utility area,etc. Pipes shall be laid in vertical stack and sunken in floors as per approved drawings with proper alignment and gradient as per the drawings with proper split clamp,anchor fastener and 10 mm thread rod supports. Wall cutting shall be done using wall cutting machine, and chasing to be done using electric jack hammer machine. Cutting and chasing with hammer shall not be permitted. Pipes and fittings shall be cleaned with pipe cleaners and joined by approved approved make solvent cement. After laying the pipes, before closing the pipes, gravity test to be conducted and get the approval from the Engineer-in-charge. Chased portions shall be covered with cement mortar. Work includes making required size holes in brick walls wherever necessary and re do same with water proofing components to the entire satisfaction of Engineer-in-charge.etc complete. All the stub outs shall be closed with proper end caps till of installation of sanitary wares and accessories etc. complete.<br>

105

-

-

... More
od295651/2023_2024 : Providing, fixing and testing of approved make of 75 mm dia SWR - B- Class PVC pipes and fittings confirming to IS 13592-1992. and fittings (available fittings in market and fabricated fittings ) such as tee, elbow, coupler, etc. conforming to 14735 with latest amendment for soil and waste pipe works in toilets and utility area,etc. Pipes shall be laid in vertical stack and sunken in floors as per approved drawings with proper alignment and gradient as per the drawings with proper split clamp,anchor fastener and 10 mm thread rod supports. Wall cutting shall be done using wall cutting machine, and chasing to be done using electric jack hammer machine. Cutting and chasing with hammer shall not be permitted. Pipes and fittings shall be cleaned with pipe cleaners and joined by approved approved make solvent cement. After laying the pipes, before closing the pipes, gravity test to be conducted and get the approval from the Engineer-in-charge. Chased portions shall be covered with cement mortar. Work includes making required size holes in brick walls wherever necessary and re do same with water proofing components to the entire satisfaction of Engineer-in-charge.etc complete. All the stub outs shall be closed with proper end caps till of installation of sanitary wares and accessories etc. complete.<br>

3

-

-

... More
od295652/2023_2024 : Providing, fixing and testing of approved make of 50 mm dia SWR - B- Class PVC pipes and fittings confirming to IS 13592-1992. and fittings (available fittings in market and fabricated fittings ) such as tee, elbow, coupler, etc. conforming to 14735 with latest amendment for soil and waste pipe works in toilets and utility area,etc. Pipes shall be laid in vertical stack and sunken in floors as per approved drawings with proper alignment and gradient as per the drawings with proper split clamp,anchor fastener and 10 mm thread rod supports. Wall cutting shall be done using wall cutting machine, and chasing to be done using electric jack hammer machine. Cutting and chasing with hammer shall not be permitted. Pipes and fittings shall be cleaned with pipe cleaners and joined by approved approved make solvent cement. After laying the pipes, before closing the pipes, gravity test to be conducted and get the approval from the Engineer-in-charge. Chased portions shall be covered with cement mortar. Work includes making required size holes in brick walls wherever necessary and re do same with water proofing components to the entire satisfaction of Engineer-in-charge.etc complete. All the stub outs shall be closed with proper end caps till of installation of sanitary wares and accessories etc. complete.<br>

59.5

-

-

... More
od295955/2023_2024 : Providing and fixing Stainless Steel A ISI 304 (18/8) Kitchen sink with drain board&nbsp;510x1040 mm bowl depth 250 mm&nbsp;as per IS 13983 with C.I. brackets , 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required, grouting the joints etc complete as per directions of Engineer-in-charge<br>

7

-

-

... More
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

2.77

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

30.24

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

300

-

-

... More
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate

23.75

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

633.64

-

-

... More
od298083/2023_2024 : Providing and fixing Handicap wall mounted Grab bar 600 mm Jaquar make or equivalent complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality including cost of materials and labour charges etc complete as per the direction of Engineer-in-charge.<br>

21

-

-

... More
od298084/2023_2024 : Providing and fixing Handicap wall mounted Grab bar Vertical Swing, Satin Jaquar make or equivalent complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality including cost of materials and labour charges etc complete as per the direction of Engineer-in-charge.<br>

7

-

-

... More
od298554/2023_2024 : Providing and fixing CP Brass toilet paper holder with flap guard of superior quality (Jaguar or equivalent make) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.<br>

42

-

-

... More
od298555/2023_2024 : Providing and laying in position ready mixed light weight concrete using thermocol<br>beads/perlite/vermiculite, in toilet sunken slab areas, with cement content as per approved design mix and<br>manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads<br>and lifts, having continuous agitated mixer, manufactured as per mix design of specified grade for plain<br>cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding<br>the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended<br>proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing<br>strength and durability as per direction of the Engineer - in - charge.

71.23

-

-

... More
od299301/2023_2024 : Providing and fixing slab for kitchen platforms, vanity counters, window sills, facias and<br>similar locations, using 15 mm thick full body vitrified tile slab of size 2400x800 mm, conforming to IS:15622,<br>approved make, shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4<br>coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including<br>rubbing, curing, edge moulding and polishing to edges to give high gloss finish etc. complete at all levels. i

38.01

-

-

... More
od299725/2023_2024 : Providing half brick masonry with common burnt clay F.P.S. (non modular) bricks of class<br>designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure for creating ledge wall and filling after fixing concealed cistern etc complete as per direction of Engineer-in-charge.

70.14

-

-

... More
od299726/2023_2024 : Providing and fixing Stainless steel Towel rod 600 mm long or nearest available length Jaquar make or equivalent complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality including cost of materials and labour charges etc complete as per the direction of Engineer-in-charge.<br>

7

-

-

... More
od299727/2023_2024 : Providing and fixing Stainless steel towel ring trapezoidal/round shape with concealed fittings arrangement of approved quality Jaguar make or equivalent including cost of materials and labour charges etc complete as per the direction of Engineer-in-charge.<br>

14

-

-

... More
od299823/2023_2024 : Supplying, installing, testing and commissioning of glazed under counter wash basin<br>(Hindware make model Garnet cat. no. 10080 or equivalent), with pressmatic pillar cock (Jaquar make model<br>no. PRS-031L65 or equivalent) , CP waste with overflow (pop-up), 32mm dia CP bottle trap with extension<br>pipe, supporting CI bracket to support basin, 1 No. 15mm CP angle valve with 450mm long CP connection<br>pipe and CP wall flanges, all complete set of approved make.

28

-

-

... More
od300483/2023_2024 : Supplying and fixing CP Robe hook Jaquar make or equivalent including cost of materials and labour charges etc complete as per the direction of Engineer-in-charge.

7

-

-

... More
od300487/2023_2024 : Providing and fixing square - mouth SW Gully trap class SP-1 complete with CI gratingbrick masonry chamber with water tight CI cover with frame of 300x300mm size (inside) the weight of coverto be not less than 4.50kg and frame not to be less than 2.70 kg as per standard design, 150x 100 mmsize P type, With Sewer bricks conforming to IS: 4885

4

-

-

... More
od300488/2023_2024 : Providing and fixing Ductile Iron (Hinged Type) cover and frame.<br> 900X900mm size125kg wt for Sump Tank<br><br>

1

-

-

... More
100.41.13 : Wall bores in brick masonry walls upto 20cmthick for providing pipe 50mm to 100mm size including redoing it with cement mortar on 1:6 cement plastering sides etc. NEW DATA (Prepared based on PHED SDB Vol II - Item No.1050) Details of Cost For Each

7

-

-

... More
100.41.14 : Wall bores in brick masonry walls above 20cmand upto 30cm thick for providing pipe 50mm to 100mm size including redoing it with cement mortar on 1:6 cement plastering sides etc. NEW DATA (Prepared based on PHED SDB Vol II - Item No.1051)

7

-

-

... More
100.41.23 : Boring RCC slab above 10cm and upto 12cm thick for providing pipes or fittings of size 50 to 60mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. NEW DATA (Prepared based on PHED SDB Vol II - Item No.1060)

7

-

-

... More
100.41.24 : Boring RCC slab above 12cm and upto 15cm thick for providing pipes or fittings of size 50 to 60mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. NEW DATA (Prepared based on PHED SDB Vol II - Item No.1061)

1

-

-

... More
100.41.27 : Boring RCC slab above 10cm and upto 12cm thick for providing pipes or fittings of size 80 to 100mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. NEW DATA (Prepared based on PHED SDB Vol II - Item No.1064)

7

-

-

... More
100.41.28 : Boring RCC slab above 12cm and upto 15cm thick for providing pipes or fittings of size 80 to 100mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. NEW DATA (Prepared based on PHED SDB Vol II - Item No.1065)

1

-

-

... More
100.41.31 : Boring RCC slab above 10cm and upto 12cm thick for providing pipes or fittings of size120 mm to 150 mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. NEW DATA (Prepared based on PHED SDB Vol II - Item No.1068)

7

-

-

... More
100.41.32 : Boring RCC slab above 12cm and upto 15cm thick for providing pipes or fittings of size120 mm to 150 mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. NEW DATA (Prepared based on PHED SDB Vol II - Item No.1069)

1

-

-

... More
od300493/2023_2024 : Constructing brick masonry manhole in cement mortar 1:4 (1 cement:4 coarse sand)with RCC top slab with 1:2:4 mix(1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size),foundation concrete 1:4:8 mix (1 cement:4 coars sand:8graded stone aggregate 40mm nominal size), insideplastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat of neatcement and creating channels in cement concrete 1:2:4(1 cement:2 coarse sand :4 graded stone aggregate20mm nominla size) finished with a floating coat of neat cement complete as per standard design.<br>Insidesize 90x80 cm and 45 cm deep including C.I. cover with frame (Heavy duty) 560 mm internal diameter, totalweight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100kg),With Sewer bricks conforming to I S:4885

4

-

-

... More
od300494/2023_2024 : Making connection of drain or sewer line with existing lines including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete as per directions of Engineer-in-charge

14

-

-

... More
od300496/2023_2024 : Providing and fixing Stainless Steel AISI 304(18/8) Floor Cleanout dummy/inactive Drain Cover fixed with SS screws suitable for drain pipe size 4&quot; etc complete as per directions of Engineer-in-charge. While fixing the gratings, flooring should be cut to required size of grating, (not more than 2mm of the grating sizes) using tile cutter etc; complete. The gap should be filled with epoxy grout/silicon sealant to match the flooring color. The color and shape of the gratings shall be as per approval from the Engineer-in-charge. To avoid damage of the cleanout, cleaning of flooring shall be done before fixing of cleanout.

35

-

-

... More
od300497/2023_2024 : Solid block masonry using pre cast sold blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part 1 of 1979 for Super structure above floor two level upto floor five level for 10 cm thick wall in: Cm 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete.

1

-

-

... More
od300499/2023_2024 : Providing and fixing Stainless steel satin finish wall mounted Paper Towel Dispenser for 400-600 C/Z towels of approved make (Jaguar or equivalent make) including fixing in position as per directions of Engineer-in-charge

14

-

-

... More
od300500/2023_2024 : Providing and fixing wall mounted Aluminium/ABS material Automatic Soap Dispenser 0.8 l capacity (Jaquar make or equivalent) including fixing in position as per directions of Engineer-in-charge

14

-

-

... More
od300501/2023_2024 : Providing and fixing wall mounted Stainless steel touch free infrared Hand dryer with 1150W rated power and carbon brush motor (Jaquar make or equivalent) including fixing in position as per directions of Engineer-in-charge

14

-

-

... More
od302879/2023_2024 : Providing, fixing, testing and commissioning of white vitreous china glazed wall mounted water closet (European type) of approved make with concealed cistern and flushing plate with necessary water connection with integrated angle stop valve production cover for service opening to be cut to the length, WC outlet bend, WC connection set dia 90mm, 2 threaded rods M12 for ceramics fastening,4adjustable fastening brackets, with fastening materials, with actuator plate, complete and the EWC shall be with necessary check nut, stopcock etc., seat and lid, CP brass hinges and rubber buffers, Concealed flushing cistern with fittings supporting bolt /CI / MS brackets. etc. cutting and making good the walls and floors wherever required all complete as per specification and direction of the Engineer-in-charge<br>

7

-

-

... More
od294978/2023_2024 : Design, Manufacture, Supply, Installation, Testing, Commissioning and Earthing of the Floor panel with necessary base frame , cubicle type, made out of 1.6mm thick CRCA sheet, totally enclosed , free standing, floor mounting, dust and vermin proof, indoor, compartmentalized, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size wires/cable, interconnection, duly powder coated with seven tank process etc. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) . All breaker should provide free potential contact for status monitoring through BMS for ON/OF and trip status separate compartment. MCCB shall have inbuilt shunt trip coil. All the meter should have RS 485 Modbus output for BMS integration. INCOMER:-1 No 240A 4P 25KA MCCB with Over current and short circuit release,1 Set and 240/5A CT CL 0.5s 15VA for metering, 1 No. tested energy meter with RS485 port, With sealing provision ,3 Sets LED type RYB indication lamp with control MCBs, 3 Sets LED type ON, OFF ,TRIP indication lamp with control MCBs OUTGOING -5Nos -63A TP+N 16KA MCCB, 1Nos -100A TP+N 16KA MCCB with Over current and short circuit release with tested energy meter (TVM/TOD) with RS485 port, suitable CTs Class .5s with sealing provision for meters, each with 1 Sets LED type RYB indication lamp with control MCBs, ON,OFF,TRIP.BUS BAR RATING :One set: 300A TPN 25KA for 1 sec. Aluminum bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus, PH: 1R 40 x 10mm Al.Flat,N:1R 20 x 10mm Al. Flat, Earth:1R 25 x 3mm Cu. Flat.

2

-

-

... More
od294979/2023_2024 : Design, Manufacture, Supply, Installation, Testing, Commissioning and Earthing of the wall panel with necessary base frame , cubicle type, made out of 1.6mm thick CRCA sheet, totally enclosed , dust and vermin proof, indoor, compartmentalized, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size wires/cable, interconnection, duly powder coated with seven tank process etc. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) . All breaker should provide free potential contact for status monitoring through BMS for ON/OF and trip status separate compartment. MCCB shall have inbuilt shunt trip coil. All the meter should have RS 485 Modbus output for BMS integration. INCOMER:-1 No 250A 4P 25KA MCCB with Over current and short circuit release,1 Set and 250/5A CT CL 0.5s 15VA for metering, 1 No. tested energy meter( MDM) with RS485 port, With sealing provision ,3 Sets LED type RYB indication lamp with control MCBs, 3 Sets LED type ON, OFF ,TRIP indication lamp with control MCBs OUTGOING -2Nos -100A TP+N 16KA MCCB, 2Nos -63A TP+N 16KA MCCB with Over current and short circuit release with tested energy meter (TVM/TOD) with RS485 port, suitable CTs Class .5s with sealing provision for meters, each with 1 Sets LED type RYB indication lamp with control MCBs, ON,OFF,TRIP.BUS BAR RATING :One set: 300A TPN 25KA for 1 sec. Aluminum bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus, PH: 1R 40 x 10mm Al.Flat,N:1R 20 x 10mm Al. Flat, Earth:1R 25 x 3mm Cu. Flat.

1

-

-

... More
od294980/2023_2024 : Design, Manufacture, Supply, Installation, Testing, Commissioning and Earthing of the Floor panel with necessary base frame , cubicle type, made out of 1.6mm thick CRCA sheet, totally enclosed , free standing, floor mounting, dust and vermin proof, indoor, compartmentalized, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size wires/cable, interconnection, duly powder coated with seven tank process etc. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) . All breaker should provide free potential contact for status monitoring through BMS for ON/OF and trip status separate compartment. MCCB shall have inbuilt shunt trip coil. All the meter should have RS 485 Modbus output for BMS integration. INCOMER:-1 No 100A 4P 25KA MCCB with Over current and short circuit release,1 Set and 100/5A CT CL 0.5s 15VA for metering, 1 No. tested energy meter( MDM) with RS485 port, With sealing provision ,3 Sets LED type RYB indication lamp with control MCBs, 3 Sets LED type ON, OFF ,TRIP indication lamp with control MCBs OUTGOING -5Nos -62A 4P10KA MCB and 4 nos-32A 4P 10KA MCB with tested energy meter (TVM/TOD) with RS485 port, suitable CTs Class .5s with sealing provision for meters, each with 1 Sets LED type RYB indication lamp with control MCBs, ON,OFF,TRIP.BUS BAR RATING :One set: 300A TPN 25KA for 1 sec. Aluminum bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus, PH: 1R 40 x 10mm Al.Flat,N:1R 20 x 10mm Al. Flat, Earth:1R 25 x 3mm Cu. Flat.

2

-

-

... More
90.14.10.3 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.

7

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

21

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

15

-

-

... More
2.3.7 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2 + 8 way, Double door

5

-

-

... More
2.3.8 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2+12 way, Double door

5

-

-

... More
2.4.2 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door

7

-

-

... More
2.4.3 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door

10

-

-

... More
2.4.6 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4+24), Double door

7

-

-

... More
2.5.1 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door

3

-

-

... More
2.5.2 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

750

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

30

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

20

-

-

... More
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral

1

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

60

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

20

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

10

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

10

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

10

-

-

... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

10

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

10

-

-

... More
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

350

-

-

... More
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

150

-

-

... More
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
od293296/2023_2024 : JUNCTION BOX :Supply, installation &amp; fixing of the 310 mm X 50 mm size of junction boxes made out of 1 mm thick galvanized sheet steel junction boxes with Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc

50

-

-

... More
od293316/2023_2024 : JUNCTION BOX :Supply, installation &amp; fixing of the 110 mm X 50 mm size of junction boxes made out of 1 mm thick galvanized sheet steel junction boxes with Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.

250

-

-

... More
od293300/2023_2024 : JUNCTION BOX :Supply, installation &amp; fixing of the 160 mm X 50mm size of junction boxes made out of 1 mm thick galvanized sheet steel junction boxes with Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.

60

-

-

... More
od293303/2023_2024 : JUNCTION BOX :Supply, installation &amp; fixing of the 250X250X60-75mm junction box made out of 1 mm thick galvanized sheet steel junction boxes with Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.

100

-

-

... More
od293305/2023_2024 : RACEWAYS :Supply, installation & fixing of the following size of Raceways made out of 1.5-3 mm thick galvanized sheet steel with Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.<br>100x38X1.6mm GI Race ways floor trunking Including required under floor access outlet, under floor cross overs, under floor vertical access units, single compartment as specified incl joint sleeves

500

-

-

... More
od293307/2023_2024 : RACEWAYS :Supply, installation & fixing of the following size of Raceways made out of 1.5-3 mm thick galvanized sheet steel with Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.<br>150x38X1.6mm GI Race ways floor trunking Including required under floor access outlet, under floor cross overs, under floor vertical access units, single compartment as specified incl joint sleeves

250

-

-

... More
od293308/2023_2024 : RACEWAYS :Supply, installation & fixing of the following size of Raceways made out of 1.5-3 mm thick galvanized sheet steel with Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc.<br>300x38X1.6mm GI Race ways floor trunking Including required under floor access outlet, under floor cross overs, under floor vertical access units, single compartment as specified incl joint sleeves

150

-

-

... More
od293309/2023_2024 : RACEWAYS :Supply, installation & fixing of the following size of Raceways made out of 1.5-3 mm thick galvanized sheet steel with Rate shall be inclusive of all Civil works for concealing, floor finish, Curing, etc. <br>225x38X1.6mm GI Race ways floor trunking Including required under floor access outlet, under floor cross overs, under floor vertical access units, single compartment as specified incl joint sleeves

150

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

350

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

50

-

-

... More
5.16 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

200

-

-

... More
od295241/2023_2024 : Providing and fixing 8 swg GI wire<br> GI wire on surface or in recess for connections etc. as required.<br>

300

-

-

... More
od302454/2023_2024 : Supply Installation testing and commissioning of 12 way 25x3mm copper earth bus with all accessories as required.

14

-

-

... More
od302455/2023_2024 :  Supply Laying and testing and commissioning of 10 SWG bare Cu. Wire

200

-

-

... More
od302457/2023_2024 :  Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

14

-

-

... More
od293317/2023_2024 : WIRING - CIRCUIT CUM POINT WIRING The rates for all point wiring items shall also include supplying and fixing of the Conduits, conduit specials, bushes and other fittings,Approved GI saddles and grouting the same for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,All work materials necessary for wiring a point circuit of any length from the Final Distribution Board to connector via switch and shall include the circuit wiring also except where identified. Primary Light / Fan Point Wiring: Supply, wiring, connecting commissioning of 3Runs 2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with moulded front plate in GI anodised manufacturer&apos;s mounting box fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit and for Vertical and horizontal drops concealed PVC conduits can be used. Accordingly the length of the conduit can be calculated.

400

-

-

... More
od293318/2023_2024 : WIRING - CIRCUIT CUM POINT WIRING.The rates for all point wiring items shall also include supplying and fixing of the Conduits, conduit specials, bushes and other fittings,Approved GI saddles and grouting the same for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,All work materials necessary for wiring a point circuit of any length from the Final Distribution Board to connector via switch and shall include the circuit wiring also except where identified. Secondary Light Points: The secondary light points will have to be wired from the primary light point as mentioned above.

650

-

-

... More
od293327/2023_2024 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 2.50 sq mm for ups socket(white colour)

1500

-

-

... More
od293328/2023_2024 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 2.50 sq mm for Raw power socket in black colour.

1000

-

-

... More
1.7.2 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire

1500

-

-

... More
od293329/2023_2024 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required<br>2 X 4 sq. mm + 1 X 2.5 sq. mm earth wire

600

-

-

... More
od293332/2023_2024 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC<br> insulated copper conductor, single core cable in surface/ recessed steel conduit as required<br>2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

1250

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

500

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

200

-

-

... More
1.21.5 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm

50

-

-

... More
1.24.2 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch

1400

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

750

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

1400

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

750

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

820

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

700

-

-

... More
90.12.7.35 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

35

-

-

... More
90.12.1.16 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).

91

-

-

... More
90.12.7.15 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

56

-

-

... More
90.12.6.17 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

30

-

-

... More
90.12.6.18 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

30

-

-

... More
90.12.7.18 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

30

-

-

... More
90.12.6.13 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

350

-

-

... More
90.12.6.14 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

200

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

10

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

10

-

-

... More
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

15

-

-

... More
9.1.9 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 25 sq. mm (25mm)

10

-

-

... More
9.1.10 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 35 sq. mm (28mm)

10

-

-

... More
9.1.11 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 50 sq. mm (32mm)

10

-

-

... More
9.1.12 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm)

10

-

-

... More
od295367/2023_2024 : Supply, Installation, testing & commissioning of following UPS System with built-in anti-harmonic filter, Preferably with active filter and all parameter in THDi and power factor shall be mentioned for percentage loading from 40% to 100%. , (internal cabling if any) for reducing input thdi to < 3 to 5% and improve PF togreater that or equal to 0.95. The same shall be feasible to use in suitable for parallel redundant configuration in future. This UPS shall have 3 phase input and three phase output as per the detailed specification, data sheet, drawings.. and Supply, Installation, testing & commissioning of SMF batteries required for 30 min backup using Global Yuasa / Equivalent make for UPS units, with MS powder coated battery racks. With ventilation louver and covers including Supply, Installation, testing & commissioning of Battery control switch ( MCCB ) at Battery bank . The battery control switch shall be having under voltage provision. The breaker shall be fitted in the battery rack itself. 20KVA

2

-

-

... More
od295368/2023_2024 : Supply, Installation, testing &amp; commissioning of following UPS System with built-in anti-harmonic filter, Preferably with active filter and all parameter in THDi and power factor shall be mentioned for percentage loading from 40% to 100%. , (internal cabling if any) for reducing input thdi to &lt; 3 to 5% and improve PF togreater that or equal to 0.95. The same shall be feasible to use in suitable for parallel redundant configuration in future. This UPS shall have 3 phase input and three phase output as per the detailed specification, data sheet, drawings.. and Supply, Installation, testing &amp; commissioning of SMF batteries required for 30 min backup using Global Yuasa / Equivalent make for UPS units, with MS powder coated battery racks. With ventilation louver and covers including Supply, Installation, testing &amp; commissioning of Battery control switch ( MCCB ) at Battery bank . The battery control switch shall be having under voltage provision. The breaker shall be fitted in the battery rack itself. 40KVA

2

-

-

... More
od295369/2023_2024 : Supply, installation, and commissioning of 2kva UPS Single phase in and<br>out. with indoor (IP20) with 15-20 min backup battery @ 3kva with min VAH<br>of 1871 smf battery of reputed approved make Exide/quanta including rack<br>and interconnecting cables), Input pf >0.99, Internal Isolation transformers<br>at Input, double conversion technology with input voltage range 160-300 @<br>full load, 50Hz Single Phase, output 230V, 50Hz Single phase, It shall be 100%<br>generator compatible, with Efficiency > 87% and output power factor unity (<br>3kVA= 3kW), Eco mode Efficiency 98% and including all accessories etc. as<br>required. The acoustic noise at 1m of the system should be <50dB.The system<br>shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS,<br>ROHS, Certificates, and relevant IS standards. The system shall be true online<br>double - conversion DSP based UPS system and also UPS shall be with<br>automatic bypass built in. The system shall have IGBT rectifier and inverter. warranty 2 years for UPS and batteries. cost including batteries

7

-

-

... More
od295370/2023_2024 : Providing and Fixing of Electrical ISI Grade Rubber Mat suitable for 11000Volts Switchboards.

10

-

-

... More
od296289/2023_2024 : Supply installation testing and commissioning of 18 W, Surface mounted downlight LED CCT: 3600 to 5700 with all hardwires required as per the site conditions and as per the direction of engineer in charge.Min cost Rs. 2800/-

115

-

-

... More
od296300/2023_2024 : Supply, Installation, Testing and Commissioning of single 4 Feet feet patty type fittings CCT: 3600 to 5700 with all accessories like low loss ballast along with 2x20w Triphosphorous coat high lumen lamps and fixing the same in the wall / ceiling with wooden blocks, screws ,hardwires required as per the site conditions and direction of Engineer in charge. Min cost Rs. 1500/-

38

-

-

... More
od296310/2023_2024 : Supply, Installation, Testing and Commissioning of 10- 20W decorative suspended Pendent mounted down light CCT: 3600 to 5700 The supply of accessories like clamps, supporting brackets and hardware as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions and directions of Engineer in charge. Min Cost Rs.2700/-

393

-

-

... More
od296311/2023_2024 : Supply, Installation, Testing and Commissioning of 20W decorative suspended Pendent down light CCT: 3600 to 5700.The supply of accessories like clamps, supporting brackets and hardware as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions and directions of Engineer in charge Min cost Rs. 6000/-

24

-

-

... More
od296312/2023_2024 : Supply, Installation, Testing and Commissioning of10- 20W decorative suspended Pendent down light CCT: 3600 to 5700 The supply of accessories like clamps, supporting brackets and hardware as required and interconnecting with 3 core 1.5 sq mm PVC insulated FRLS copper wire with all accessories required as per site conditions and directions of Engineer in charge. Min cost Rs. 3500/-

65

-

-

... More
od296313/2023_2024 : Supply, Installation, Testing and Commissioning of single 8 feet 40 W LED Linear suspended type fittings with all accessories Copper ballast and 2.5 mtr hanging chain required as per site conditions and directions of Engineer incharge (Cost Including the earthing of fixture) Min cost Rs. 6200/-

79

-

-

... More
od296315/2023_2024 : Supply, Installation, Testing and Commissioning of single 4 feet 20 W LED Linear suspended type fittings with all accessories Copper ballast and 2.5 mtr hanging chain required as per site conditions and directions of Engineer in charge. (Including the earthing of fixture) (as per the Wipro Cat No: LM31-211-XXX-57WCG1 or EQL

226

-

-

... More
od296316/2023_2024 : Supply, Installation, Testing and Commissioning of 9-10W LED recess down light fitting with all accessories and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire and fixing the same in the ceiling as per site conditions and directions of Engineer incharge Min cost Rs. 1000/-

10

-

-

... More
od296317/2023_2024 : Supply, Installation, Testing and Commissioning of 18W LED recess down light fitting with all accessories and interconnecting with 3 core 1.5 sq mm PVC insulated FRLS copper wire and fixing the same in the ceiling as per site conditions and directions of Engineer in charge. Min cost Rs. 1250/-

210

-

-

... More
od296644/2023_2024 : Supply installation testing and commissioning of decorative suspended LED luminaire CCT: 3600 to 5700 . Decorative ring type fitting with the ring color should be inline with the CCT of the luminaire. System wattage shall not be greater than 40W and system lumen shall not be less than 3600lm. The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions and directions of Engineer incharge.Min cost Rs. 8750/-

15

-

-

... More
od296645/2023_2024 : Supply, Installation, Testing and Commissioning of 40- 60W decorative suspended chandelier light CCT: 3600 to 5000 The supply of accessories like clamps, supporting brackets and hardware as required and interconnecting with 3 core 1.5 sq mm PVC insulated FRLS copper wire with all accessories required as per site conditions and directions of Engineer in charge. Min cost Rs. 1,25,000/-

1

-

-

... More
od296646/2023_2024 : Supply, Installation, Testing and Commissioning of 20 TRACK light CCT: 3600 to 5700 The supply of accessories like phaser track clamps, supporting brackets , connections and hardware as required and interconnecting with 3 core 1.5 sq mm PVC insulated FRLS copper wire with all accessories required as per site conditions and directions of Engineer in charge. Min cost 3750/-

5

-

-

... More
od297064/2023_2024 : Supply, Installation, Testing and Commissioning of 20 -30 W decorative suspended 1 meter cuve type linear profile LED fitting CCT: 3600 to 5700. The supply of accessories like clamps, supporting brackets and hardware as required and interconnecting with 3 core 1.5 sq mm PVC insulated FRLS copper wire with all accessories required as per site conditions and directions of Engineer in charge. Min cost Rs. 8000/-.

20

-

-

... More
od297065/2023_2024 : Supply installation testing and commissioning of profile light, the aluminum channel size between 30-100 mm Size with 18-20 W strip light of drive in every 5 meter as complete as per the direction of engineer in charge Min cost Rs. 550/-

50

-

-

... More
od297368/2023_2024 : Supply, Installation, Testing and Commissioning of 30- 40W decorative suspended t down light CCT: 3600 to 5700 The supply of accessories like clamps, supporting brackets and hardware as required and interconnecting with 3 core 1.5 sq mm PVC insulated FRLS copper wire with all accessories required as per site conditions and directions of Engineer in charge. Mn cost Rs. 8000/-

30

-

-

... More
od298078/2023_2024 : Design Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc. suitable for hall have automatic force shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 4.5 TR (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

11

-

-

... More
od299015/2023_2024 : Disign Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc. suitable for hall have automatic force<br>shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 4 TR (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

26

-

-

... More
od299016/2023_2024 : Design Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc. suitable for hall have automatic force<br>shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 3 TR (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

11

-

-

... More
od299017/2023_2024 : <br>Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc. suitable for hall have automatic force<br>shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2.5 TR

25

-

-

... More
od299018/2023_2024 : Design Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc. suitable for hall have automatic force<br>shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2 TR (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

12

-

-

... More
od299019/2023_2024 : Design Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc. suitable for hall have automatic force<br>shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. .1.6 TR (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

37

-

-

... More
od299020/2023_2024 : Design Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc. suitable for hall have automatic force<br>shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. .1.3 TR (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

3

-

-

... More
od299021/2023_2024 : Design Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc. suitable for hall have automatic force<br>shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 1.0 TR (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

50

-

-

... More
od299022/2023_2024 : Design Supply, installation, testing and commissioning of following minimum capacity 4 way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter ,fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc. suitable for hall have automatic force <br> shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 0.8 TR (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

16

-

-

... More
od298079/2023_2024 : Design Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The unit consist of DC fan motor with aero-spiral fan blade, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and ref net kits. Rate inclusive of R-410A refrigerant oil pre charging, power cable from nearest isolator, vibration isolators, supports, necessary foundation / pedestal works etc. 14 HP (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

5

-

-

... More
od298080/2023_2024 : Design Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The unit consist of DC fan motor with aero-spiral fan blade, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and ref net kits. Rate inclusive of R-410A refrigerant oil pre charging, power cable from nearest isolator, vibration isolators, supports, necessary foundation / pedestal works etc. 16 HP (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

1

-

-

... More
od298081/2023_2024 : Design Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The unit consist of DC fan motor with aero-spiral fan blade, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and ref net kits. Rate inclusive of R-410A refrigerant oil pre charging, power cable from nearest isolator, vibration isolators, supports, necessary foundation / pedestal works etc. 18 HP (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

15

-

-

... More
od298082/2023_2024 : Design Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The unit consist of DC fan motor with aero-spiral fan blade, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and ref net kits. Rate inclusive of R-410A refrigerant oil pre charging, power cable from nearest isolator, vibration isolators, supports, necessary foundation / pedestal works etc. 4 HP (The cost including design , preparation of shop drawing etccomplete as per the direction of engineer incharge.)

14

-

-

... More
od298212/2023_2024 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class- O tubular insulation /with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

665

-

-

... More
od298213/2023_2024 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class- O tubular insulation /with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

770

-

-

... More
od298214/2023_2024 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class- O tubular insulation /with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

525

-

-

... More
od298215/2023_2024 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class- O tubular insulation /with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

375

-

-

... More
od298216/2023_2024 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class- O tubular insulation /with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

330

-

-

... More
od298217/2023_2024 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class- O tubular insulation /with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

300

-

-

... More
od300242/2023_2024 : Supply ,Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class- O tubular insulation /with Class- O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

140

-

-

... More
od300243/2023_2024 : Supply ,Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class- O tubular insulation /with Class- O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

200

-

-

... More
od300244/2023_2024 : Supply ,Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class- O tubular insulation /with Class- O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

250

-

-

... More
od300250/2023_2024 : Supply and erection of the following UPVC pipe with all joints, reducer, necessary elbows and tees, supporting arrangements, etc. Rate shall inclusive of thermal insulation. The pipe sizes and insulation thickness as follows 40mm dia with 13mm thick insulation

420

-

-

... More
od300251/2023_2024 : Supply and erection of the following UPVC pipe with all joints, reducer, necessary elbows and tees, supporting arrangements, etc. Rate shall inclusive of thermal insulation. The pipe sizes and insulation thickness as follows 32mm dia with 13mm thick insulation

850

-

-

... More
od300252/2023_2024 : Supply and erection of the following UPVC pipe with all joints, reducer, necessary elbows and tees, supporting arrangements, etc. Rate shall inclusive of thermal insulation. The pipe sizes and insulation thickness as follows 25mm dia with 13mm thick insulation

500

-

-

... More
od300269/2023_2024 : supply installation testing commissioning and end termination of 2C x 1.5 Sqmm PVC Copper Armoured Cable - Communication and Control cabling between indoor and outdoor units. 

3800

-

-

... More
od300291/2023_2024 : Supply, installation, balancing and commissioning of factory fabricated .63 mm GSS sheet metal rectangular/round/ovel ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006.

50

-

-

... More
od300292/2023_2024 : Supply ,Installation & Commissioning of Centrifugal Inline Exhaust fan with Static Pressure - 15mm for following fan capacity.<br>Toilet Exhaust air fan - 700CFM

2

-

-

... More
od300293/2023_2024 : Supply ,Installation & Commissioning of Centrifugal Inline Exhaust fan with Static Pressure - 15 mm for following fan capacity.<br>Closed cabins Fresh air fan with prefilter - 1500 CFM

1

-

-

... More
od300294/2023_2024 : Supply ,Installation & Commissioning of Centrifugal Inline Exhaust fan with Static Pressure - 15 mm for following fan capacity.<br>Electrical room Exhaust air fan - 500 CFM

4

-

-

... More
od302924/2023_2024 : Supply installation testing and commissioning of 4P 63A MCB Outgoing 3 no 40A 300 mA RCBO with outdoor Weather proof Enclosure box and stand

3

-

-

... More
od302925/2023_2024 : Supply installation testing and commissioning of 4P 63A MCB Outgoing 1 no 40A 300 mA RCBO 2 no 32A 300 mA RCBO with outdoor Weather proof Enclosure box and stand

1

-

-

... More
od302926/2023_2024 : Supply installation testing and commissioning of 4P 63A MCB Outgoing 2 no 40A 300 mA RCBO 1 no 32A 300 mA RCBO with outdoor Weather proof Enclosure box and stand

3

-

-

... More
od301818/2023_2024 : Disconnection of existing sprinkler points from fire line and the cost including necessary cutting, jointing and welding and all the material required as complete as per the direction of engineer incharge.

21

-

-

... More
od301819/2023_2024 : Addition of sprinkler points in the existing fire line and the cost including necessary cutting and <br>welding. The cost including all the material required as complete as per the direction of engineer incharge.

12

-

-

... More
od301820/2023_2024 : CO2 FIRE EXTINGUISHER Supply and installation of CO2 type Fire Extinguishers of following capacity Conforming to IS: 13849 with initial gas, filled in steel cylinders, safety valve with lock, discharge hose and horn etc and with ISI mark. 4.5 Kg Capacity

42

-

-

... More
od302293/2023_2024 : Supply and installation of Powder Fire Extinguisher (Stored Pressure type) (Powder pressurized with dry nitrogen gas at 15 bar.) capacity: 6kg duly ISI marked conforming to IS: 15683:2006, with IS 14609 ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual,Body Hydrotested at 35 bar, Operating temperature -30°C to +55°C, external epoxy powder coating with PO Red Shade No. 538 of IS 5, and floor stand or Wall Mount Bracket including accessories as required as per site condition

10

-

-

... More
od301822/2023_2024 : Providing and installing Fire and emergency signage Boards( Fire exit directions, Fire Extinguisher, Fire duct, safe material handling procedures, Fire assembly area indications etc,) The signages should be battery backup with self illumination

40

-

-

... More
od301823/2023_2024 : supply and installation of FE36 Automatic wall Mounted Clean agent Extinguisher - 5 Kg with Wall mounting accessories including nozzle(57deg), pressure guage. ISI approved

14

-

-

... More
od301825/2023_2024 : Supplying, installation, testing & commissioning of heat detector operating at 54ºC/<br>57ºC with rate of rise cum fixed tempreature (dual thermistor) type with mounting<br>base complete with all connection etc. as required.

7

-

-

... More
od301826/2023_2024 : Supplying, installation, testing & commissioning of smoke detector with builtin LED<br>and mounting base complete with all connections etc. as required.

15

-

-

... More
od301828/2023_2024 : Providing and installing of Fire Evacuation Plan with route in rectangular Acrylic sheet with ss bolt of size 600 x 450mm &amp; 2 to 3mm thick

14

-

-

... More
od301829/2023_2024 : Supplying, installation, testing & commissioning response indicator on surface/ recess MS box having two LEDs metallic cover complete with all connections etc. as required.

50

-

-

... More
od301830/2023_2024 : Supplying, installation, testing & commissioning of fault isolator complete with base as required

10

-

-

... More
od301831/2023_2024 : Supplying, installation, testing & commissioning of addressable manual call point<br>complete as required.

10

-

-

... More
od301832/2023_2024 : Supplying, installation, testing & commissioning of addressable horn cum strobe<br>complete as required.

10

-

-

... More
od301833/2023_2024 : Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with<br>annealed copper conductor having XLPE insulation, steel wire armouring & FRLS<br>outer sheath complete as required.

100

-

-

... More
od301834/2023_2024 : Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all<br>ancillaries and accessories like coupler etc. as required

50

-

-

... More
od301835/2023_2024 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.<br>25 mm

100

-

-

... More
od301836/2023_2024 : INTELLIGENT FIRE ALARM SYSTEM- Analogue Addressable Intelligent 1 loop Fire alarm control panel, provision to make with a minimum capacity of 125 devices + 125 modules per loop, with battery back up for 6 Hrs during normal operation and 15 minutes alarm operation, with minimum 160 Character LCD display, necessary interface card to connect a repeater panel and all hardware & software as per specification.

1

-

-

... More
od301838/2023_2024 : Supplying, installation, testing and commissioning of 480W Power Amplifier

1

-

-

... More
od301839/2023_2024 : Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required as per the direction of engineer incharge

80

-

-

... More
od301840/2023_2024 : Supplying and drawing of cable Fire Retardant PVC insulated copper conductor<br>cable in the existing surface / recessed steel conduit of following pairs, cores and<br>size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm

300

-

-

... More
od301841/2023_2024 : supply installation testing and commissioning of 12 zone talk back system

1

-

-

... More
od297573/2023_2024 : PVC TRUNKING/RACEWAYS :Supply and Installation of 100X35 mm PVC Trunking for the cable entry of network rack locatioans as per the direction of engineer incharge.

250

-

-

... More
od301754/2023_2024 : Supply installation testing and commissioning of 12 core OFC fiber sm 9/125 micron

250

-

-

... More
od301801/2023_2024 : Supply installation testing and commissioning of 6 core OFC fiber sm 9/125 micron

400

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

33000

-

-

... More
od301750/2023_2024 : supply , installation testing commissioning of Cat 6A U/FTP Multi-stranded Patch cord 1 Meter

700

-

-

... More
od301753/2023_2024 : Supply , installation, testing and commissioning of Cat 6 7 feet patch cord at both end 100% yellow(for both voice & data)

600

-

-

... More
od301751/2023_2024 : Supply installation of 2 port British style phase plate cost including PVC/ GI back box

800

-

-

... More
od301752/2023_2024 : Supply ,installation, testing, commissioning of cat6 UTP jack with strain relief and bend limiting boot ( Yellow for data and blue for voice)

1400

-

-

... More
od301762/2023_2024 : Supply installation testing and commissioning of Cat 6A 24 Port loaded Jack Panel with Rear Cable support manager for data and voice as per direction of Engineer incharge

88

-

-

... More
od301755/2023_2024 : Supply installation testing commissioning of 24 port LIU loaded with pigtail and other accessories as per the engineer incharge

10

-

-

... More
od301756/2023_2024 : Supply, installation, testing, commissioning of 12 port LIU loaded with pigtail and other accessories with the direction of Engineer in charge

10

-

-

... More
od301757/2023_2024 : Supply installation testing and commission of 19inch 9 U closed Rack with Mounting Accessories with all connected accessories including Power distribution unit with 6 Sockets as per the Engineer Incharge

3

-

-

... More
od301758/2023_2024 : Supply installation testing and commission of 19 inch 15U closed Rack with Mounting Accessories with all connected accessories including Power distribution unit with 6 Sockets as per the engineer incharge.

3

-

-

... More
od301759/2023_2024 : Supply , installation, testing and commissioning of 42 U Open Rack with Vertical HDCM , check nut , ladder set , PDU 2 nos etc

8

-

-

... More
od301769/2023_2024 : Supply, fixing , testing and commissioning of CCTV "2MP IP Indoor 1080P Dome Camera, PoE H.265+,Fixed 3.6mm Lens for 83 degree angle of view, 98ft Night Vision, DWDR, Built in Web Server allows remote viewing over network via smartphone, tablet, or PC/MAC, ONVIF Compatible"

2

-

-

... More
od301770/2023_2024 : Supplying , fixing , testing and commissioning of 32 channel NVR with, H.265/H.264 dual codec decoding, Up to 8Mp resolution preview and playback, Max 200Mbps incoming bandwidth, Support 4 SATA HDDs up to 24TB, 2 USB(1 USB3.0), 2 RJ 45 Port, HDMI / VGA simultaneous video output, Support Multi-brand network cameras, ONVIF Version 2.4 conformance, Recording, PTZ, Tour, Alarm out, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips and 4 Nos 6TB Internal Hard drive

2

-

-

... More
od301771/2023_2024 : Installation, testing and commissioning of complete CCTV system with necessary accessories required cost including SFP modules, spike surge protection and RJ45 connector etc complete as per direction of Engineer-in-charge.

1

-

-

... More
od301772/2023_2024 : Supply, installation, testing and commissioning of 24 Port Network Switch Manageable PoE[L2].2 x1G combo ports ,2 nos. of fiber port loaded with single mode transceiver, should support static routing

2

-

-

... More
od301773/2023_2024 : Supplying , fixing, testing and commissioning of "4MP IP Indoor 1080P Dome Camera, PoE H.265+,Fixed 3.6mm Lens for 83deg angle of view, 98ft Night Vision, DWDR, Built in Web Server allows remote viewing over network via smartphone, tablet, or PC/MAC, ONVIF Compatible"

42

-

-

... More
od301791/2023_2024 : supply installation testing and commissioning of Access Intelligent Controller support with following specification.<br>Face + card Face, Mi fare Smart card, reader with 50000 profiles, 2,00,000 face templates, 5,00,000 logs, IP65, IK 08 Certified.3.5"IPS Touch screen display with gorilla glass, 2MP surveillance grade camera, #3 year warranty. The device specification should match with UL 294, FCC, CE,EN specification. the cost including the required software

7

-

-

... More
od301792/2023_2024 : Supply, Installation, testing & commissioning of Exit push button<br>as per the direction of engineer in charge.

7

-

-

... More
od301793/2023_2024 : Supply installation testing and commissioning of mifare card

800

-

-

... More
od301794/2023_2024 : supply installation testing and commissioning of Electro Magnetic Lock of Suitable Capacity(single door Min 600lbs, double door min 1200 lbs) as per the direction of engineer in charge. <br>

7

-

-

... More
od301797/2023_2024 : supply installation testing and commissioning of Duct Plate for installing DCFE device.

1

-

-

... More
od301798/2023_2024 : supply installation testing and commissioning of Site Controller for Multiple Door Controllers, Controls Up to 255 Door Controllers or IO Controllers,Ethernet, RS-485, USB, Wiegand Out, Aux Input and Aux Output Port, Inbuilt Wi-Fi Module (IEEE 802.11 b/g/n), Inbuilt Bluetooth ,25,000 Users Capacity and 500,000 Events Storage, 800MHz Cortex A8 Processor, 512MB RAM, 256MB Flash and 4GB SD Card , Secured Socket Layer Certified

1

-

-

... More
od301799/2023_2024 : supply installation testing and commissioning of Input-Output Controller for Auxiliary Devices, 8 Auxiliary Input Ports to Connect Fire Alarm, Auxiliary Sensors etc, 8 Auxiliary Output Ports to Connect Siren, Elevator etc, Power over Ethernet (PoE) and RS-485,Elevator Control to Manage 8 Floors, LED Indication for Devices and Network Status

2

-

-

... More
od301800/2023_2024 : supply installation testing and commissioning of Mifare Card Based Controller<br>• Mifare card based reader, Access control and time attendance, IP 65 rating,Build-In power over ethernet (POE)<br>Build in Door Lock port, Door Sense Port.,Tri Color LED and Buzzer, 12 V DC Power Supply through Adapter OEM : m

6

-

-

... More
od308646/2023_2024 : Supply installation testing and commissioning of wireless control system should be dedicated appliance with support for up to 50 Access points day one and the deployment should scale to 100 APs in future, Fully equipped with a 1000 Base-T Ethernet Port, a USB 3.0 Port, Support for IEEE 802.3ab/u/x standards ,<br>Centralized Configuration, L2 & L3 discovery of APs, Configuration Backup & Restore, Firmware Management of APs ,Automatic channel and power management, Airtime Fairness, L2 & L3 seamless Roaming, Bandwidth Optimization based on Client, SSID etc. SSID & VLAN mapping, Band Steering, Scheduling, MAC Filter, Captive Portal.<br>Authentication – Local, RADIUS and LDAP, Dashboard with real time information on Number of clients<br>Download & Upload traffic usage ,Most Active AP, Network Traffic Usage, Floor Map based monitoring, WLAN Access Points should be from same OEM .5 Year Warranty

2

-

-

... More
od308647/2023_2024 :  Supply installation testing and commissioning of 24 Ports 10/100/1000Mbps PoE + 4 10G SFP+ ports Managed Stackable Switch with Console & Management Port , Physical Stacking, Switching Capacity - 128 Gbps, 16K Mac address, Support for IEEE 802.3at PoE+ on all 24 ports, Minimum 370 Watts POE budget, Advanced security features including IMPB, IPv6 Source Guard, IPV6 RA Guard,IPV6 DHCP Guard, IGMP Snooping V3, Traffic Segmentation, SSH V2, MAc based, Port based & host based ACL, Compound Authentication, EAP, OTP, TLS, TTLS, PEAP, IPv6 Neighbor Discoverys Flow, DHCP Server Screening , ERPS,LLDP/LLDP-MED, Built-in SNMP MIB for remote network management systems. 5 Year Warranty

7

-

-

... More
od308648/2023_2024 : Supplying and drawing of UTP 4 pair CAT 6A LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.

3000

-

-

... More
od308649/2023_2024 :  Supply installation testing and commissioning of Access points should Support IEEE 802.11 AX , Wireless Speed Up to 3600 Mbps MU-MIMO, 1024 QAM with OFDMA or Better, 1 or more 1GbE RJ-45 PoE Ports, 1 x 2.5 Gbps Ethernet,1 Console Port, WPA-PSK, WPA-TKIP, WPA2 AES, WPA2 Enterprise, WPA3 802.1x,ARP Spoofing Prevention,MAC & IP ACL, Station/SSID Isolation,Captive Portal Authentication,Rogue AP detection,Integrated Antennas 4X Dual Band internal Antenna 3.5 dBi (2.4 GHz), 5.5 dBi (5 GHz) Antenna Gain,Upto 8 or higher SSIDs with VLAN mapping,Band Steering, TWT, BSS Color,Automatic Channel Assignment,Transmit Power Control (Adjust Transmit Power on dBm),QoS, Support for Mail/Web/FTP Priority,Band Steering, Load Balance, Airtime Fairness<br>Rate Limit/Bandwidth Control, User Limiting, Wireless Scheduling,802.11e WMM, IGMP Snooping,IPv4 and IPv6 Management, 802.1Q VLANSNMP v1/v2C/v3 and Web management, Mobile APP based configuration, AP Should support hardware & Software based Management, Wall/Ceiling Mounting kit to be supplied with AP,Wi-Fi6 certified Certificate, 5 Year Warranty

50

-

-

... More
od309334/2023_2024 : Supply and installation of Work Stations (Height adjustable type - 690 mm to 1140 mm ht) 1200mm X 600mm non sharing type with table top made of 25mm thick Prelaminated particle board E1 grade conforming to IS:12823, edge finished with 2mm PVC edge banding, supported on under structure made of ERW CR Tube of appropriate size approx 16g thk powder coated with suitable levellers at either ends, Single motor leg/ Double motor leg with preset controller and Motor directly drives the spindle without a hex rod assembly and connectors with appropriate sections provided in between the leg for support; mast leg/ central leg with vertical cable raiser/vertebrae as oper requirement and horizontal continuous power beam for integrated wire management, provision for fixing sockets, desk port fitted on table top, MS perforated powder coated modesty panel of 350 mm ht at aisle and passage side, below power beam/raceway/wire tray with power box Switch mounting box is to be offered with each workstation. It is used as a plugin point to supply power to the control box and the controllers used for height adjustment. Power Box is to be offered for worktop with edge type Access Flap. Access flap / Grommet cover will be provided. MS powder coated Perforated Modesty of 300 mm ht on aisle side and passage side etc complete as per directions of Engineer-in-charge (Warranty period: 5 years) Manufacturer’s certificate to be submitted

20

-

-

... More
od309335/2023_2024 : Supply and installation of Work Stations (Open Office System) 1200mm X 600mm X 750mm ht sharing type with table top made of 25mm thick Prelaminated particle board E1 grade conforming to IS:12823, edge finished with 2mm PVC edge banding, supported on under structure made of ERW CR Tube of appropriate size approx 16g thk powder coated with suitable levellers at either ends and connectors with appropriate sections provided in between the leg for support; mast leg/ central leg with vertical cable raiser and horizontal continuous power beam for integrated wire management, provision for fixing sockets, desk port fitted on table top, soft closing access flip boxes/grommet fitted on table top as per requirement, MS perforated powder coated modesty panel of 350 mm ht at aisle and passage side, below power beam/raceway/wire tray MS powder coated Perforated Modesty of 300 mm ht etc complete as per directions of Engineer-in-charge (Warranty period: 5 years) Manufacturer's certificate to be submitted

360

-

-

... More
od309340/2023_2024 : Supply and installation of Work Stations (Open Office System) 1200mm X 600mm X 750mm ht non sharing type with table top made of 25mm thick Prelaminated particle board E1 grade conforming to IS:12823, edge finished with 2mm PVC edge banding, supported on under structure made of ERW CR Tube of appropriate size approx 16g thk powder coated with suitable levellers at either ends and connectors with appropriate sections provided in between the leg for support; mast leg/ central leg with vertical cable raiser and horizontal continuous power beam for integrated wire management, provision for fixing sockets, desk port/ soft closing access flip boxes/grommet fitted on table top as per requirement, MS perforated powder coated modesty panel of 350 mm ht at aisle and passage side, below power beam/raceway/wire tray MS powder coated Perforated Modesty of 300 mm ht etc complete as per directions of Engineer-in-charge (Warranty period: 5 years) Manufacturer's certificate to be submitted

82

-

-

... More
od309377/2023_2024 : Supply and installation of modular Work Stations sharing type with integrated storage unit of size 1200mm X 600mmx750 mm with system ht 1050/1200 mm with table top made of 25mm thick Prelaminated particle board E1 grade conforming to IS:12823, edge finished with 2mm PVC edge banding, supported on under structure made of ERW CR Tube of appropriate size approx 16g thk powder coated with suitable levellers at either ends, and connectors with appropriate sections provided in between the leg for support; mast leg/ central leg with vertical cable raiser/vertebrae as per requirement and horizontal continuous power beam for integrated wire management, provision for fixing sockets, desk port fitted on table top, MS perforated powder coated modesty panel of 350 mm ht at aisle and passage side, below power beam/raceway/wire tray with Switch mounting box is to be offered with each workstation. It is used as a plugin point to supply power to the control box and the controllers used for height adjustment. Power Box is to be offered for worktop with edge type Access Flap. Access flap / Grommet cover will be provided. Integrated storage unit should have Drawer system having two drawers top box drawer and bottom filing drawer which is equipped with features like file separators and the drawer facias are made of 18 mm thk PLB. Credenza top panel & bottom panel and vertical wire carrier panels are made from 18 m mt hk PLB. Understructure of credenza is made of leg frame assembly 40 x 20 x 1.2 mm thk tubes. Sizes 1200 mm length x 450 mm .MS powder coated Perforated Modesty of 300 mm ht on aisle side and passage side etc complete as per directions of Engineer-in-charge (Warranty period: 5 years) Manufacturer’s certificate to be submitted

54

-

-

... More
od309378/2023_2024 : Supply and installation of modular Work Stations nonsharing type with integrated storage unit of size 1200mm X 600mmx750 mm with system ht 1050/1200 mm with table top made of 25mm thick Prelaminated particle board E1 grade conforming to IS:12823, edge finished with 2mm PVC edge banding, supported on under structure made of ERW CR Tube of appropriate size approx 16g thk powder coated with suitable levellers at either ends, and connectors with appropriate sections provided in between the leg for support; mast leg/ central leg with vertical cable raiser/vertebrae as per requirement and horizontal continuous power beam for integrated wire management, provision for fixing sockets, desk port fitted on table top, MS perforated powder coated modesty panel of 350 mm ht at aisle and passage side, below power beam/raceway/wire tray with Switch mounting box is to be offered with each workstation. It is used as a plugin point to supply power to the control box and the controllers used for height adjustment. Power Box is to be offered for worktop with edge type Access Flap. Access flap / Grommet cover will be provided. Integrated storage unit should have Drawer system having two drawers top box drawer and bottom filing drawer which is equipped with features like file separators and the drawer facias are made of 18 mm thk PLB. Credenza top panel & bottom panel and vertical wire carrier panels are made from 18 m mt hk PLB. Understructure of credenza is made of leg frame assembly 40 x 20 x 1.2 mm thk tubes. Sizes 1200 mm length x 450 mm .MS powder coated Perforated Modesty of 300 mm ht on aisle side and passage side etc complete as per directions of Engineer-in-charge (Warranty period: 5 years) Manufacturer’s certificate to be submitted

56

-

-

... More
od309338/2023_2024 : Supplying and placing in position premium quality Executive tables of approved make<br>Main table of size 1650x600x750 mm, return table with storage unit of size 1200x450x750mm; pedestal of size<br>400x470x545mm. Table top made of 25 mm thick prelaminated particle board edges post formed/ 2mm PVC<br>edge banding; table supported on loop leg under structure made of diamond shape ERW CR Tube of size<br>55x55x76mm x 16g thk powder coated with suitable levellers at either ends and connectors with 50X25<br>sections provided in between the leg for support; mast leg/ central leg with vertical cable raiser and power<br>beam for integrated wire management, provision for fixing sockets, soft closing access flip boxes fitted on<br>table top, levellers made of 100% recyclable nylon bolt, metal/ prelam board modesty of 450 mm height,<br>mobile pedestal storage unit with three drawers, return storage unit with one adjustable rack and<br>prelaminated particle board side hung shutter, along with all accessories such as handles, locks, soft<br>closing hinges, sliders etc. complete as per directions of Engineer-in-charge (Warranty period: 5 years)

6

-

-

... More
od309379/2023_2024 : Supplying and placing in position meeting table of the following specifications with overall size shall be 2350 X 1150 X 740.Work top-Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade conforming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.<br>Soft closing dual access flap provided for access to power supply and data cables.<br>Understructure-The Under-structure consists of mixture of 25mm and 18mm Pre-laminated twin board of E1-P2 grade and approved shade conforming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Anodised aluminium alloy 63400 - WP profile is added at bottom edges for improving the aesthetics. The product has a knock-down construction.<br>Wire Management- A wire raiser made of 0.8mm CRCA MS IS:513. It is epoxy polyester powder coated (DFT 40-60 microns) for flow of wires and cables. A Power box with 2 cutouts on either sides for standard 8 module Anchor Roma is provided. Beside each cutout, an additional cutout with plate is provided for mounting Audio Visual Cables(eg. HDMI,VGA-A,etc).

1

-

-

... More
od309419/2023_2024 : Providing, supplying and placing of Foldable, Stackable Tables.Overall Dimension -1200 x 600 x 750 Table top should be made of 25min thk. MDF OSR board (Bottom side in white color) as per IS:12406 PU coated on top side. Legs should be made by welding the combination of MS ERW round Tube 063.5 x 2mm THK as per IS: 7138, flanges made CRCA sheet of 1.6mm thk. and 1.2mm thk. as per IS 513 and inside plates made of HR 5mm thk. sheet as per IS:2062. The Assembly will be epoxy polyester powder coated of minimum thickness 45 microns. The Table top will fold upside at offset center pivot provided on support bracket which should be Aluminum alloy (ADC12) pressure die cast part coated with epoxy polyester powder coating of minimum thickness of 45 microns. Table top connected with spring loaded mechanism with pull handle made of MS ERW 016x1 2mm thk with an inseart tube of 012.7x1.6mm thk tube as per IS:7138 coated with epoxy polyester powder coated of minimum 45 micron thickness to operate table top. Legs should be provided with casters of 065mm lockable type for ease of movement and can be locked when required at any position.

23

-

-

... More
od309420/2023_2024 : Supplying and placing in position 4 seater Meeting table of size 900 mm dia x 750 mm htof approved make and following specification: Table table top made of 25mm thick Prelaminated particleboard E1 grade conforming to IS:12823, edge finished with 2mm PVC edge banding, supported on single legunder structure made of round shape powder coated ERW CR Tube of size 100 mm x 16g thk with disc baseof suitable size with suitable levellers, soft closing aluminium access pop up type flush mounting boxesfitted on table top along with required under table wire management system etc complete as per directionsof Engineer-in-charge (Warranty period: 10 years ) Manufacturer's certificate to be submitted

7

-

-

... More
od309421/2023_2024 : Supply, fabrication and installation of Side Table of size 450x450x600 mm made with under structure of Stainless Steel 304 grade 16 gauge tubes of size 20x20mm, table top with 15mm thick full body vitrified tiles fixed to the SS under structure with required accessories, screws, clamps, adhesive etc complete. The edge of the vitrified tile slab table top bull nosed. The quoted rate shall includes the cost of all materials and labours, tools and tackles etc.

5

-

-

... More
od309422/2023_2024 : Supply, fabrication and installation of Laptop Table similar to Featherlite make Brisk /Spiky laptop stand or equivalent Warranty - 5 years

21

-

-

... More
od309423/2023_2024 : Supply and installation of Cafeteria table of size 900 Dia *750H with table top is made of 25mm E1 Grade pre-laminated particle board with PVC edge banding with understructure stainless steel pipe with X-base/disc base as per directions of Engineer-in-charge (Warranty period: 5 years

1

-

-

... More
od309404/2023_2024 : Supply and installation of mobile pedestal of size 400mm (w) X 450mm (d) X 600 mm (h) with lockable castors made with 18mm thick Prelaminated particle board E1 grade conforming to IS:12823, edge finished with 2mm PVC edge banding, pedestal shall have two equal small drawers and one larger drawer for box files and with fixtures including finger groove handle, soft closing sliders, all drawers should be lockable type, locks with two keys, the sliders should have ball bearing to ensure smooth movement, all hardware of app. make etc. complete as per directions of Engineer-in-charge (Warranty period: 5 years) Manufacturer's certificate to be submitted

150

-

-

... More
od309405/2023_2024 : Supply and installation of privacy screens of size 1050 x 400 x 8 mm with laminated lacquered glass with bevelled edges and round corners of approved colour supported on brackets ; All hardware of approved make etc. complete as per directions of Engineer-in-charge

150

-

-

... More
od309406/2023_2024 : Supply and installation of Fabric privacy screens of size 1050 x 400 mm along main spine with pin-up band on top encased in aluminium extrusion (fabric of approved quality, fire retardant & colour) supported on brackets; All hardware of approved make etc. complete as per directions of Engineer-in-charge

150

-

-

... More
od309412/2023_2024 : Supply and installation of table 4 seater round/square/rectangular shape (similar to Godrej Topo table or equivalent): worktop is made of 25mm MDF OSR with 0.4mm membrane foil on top surface. The under-structure consists of an inner tube assembly with top plate, for worktop mounting, and an outer tube assembly with round/square bottom plate. The inner and outer tube assemblies are telescopically connected. The top plate is made of 5mm thk hot rolled steel plates (HR) (as per IS:2062) and the bottom plate is made of 8mm thk hot rolled steel plates (HR) (as per IS:2062). The inner tube assembly is made of 082.5 x 2thk round electric resistance welded tubes (ERW)(as per IS:7138) and 8mm thk hot rolled steel plates (HR) (as per IS:2062) welded together using tungsten inert gas welding. The outer tube assembly is made of 89 x 2.5 thk and round electric resistance welded tubes (ERW)(as per IS:7138) and 8mm thk hot rolled steel plates (HR) (as per IS:2062) welded together using tungsten inert gas welding. The whole structure is epoxy polyester powder coated (dft 40-60 microns). The product has a knock-down construction. It is assembled using alloy steel hardware (blackened & coated with rust preventive oil)."

19

-

-

... More
od309413/2023_2024 : Supply and installation of table of 4 seater round/square/rectangular shape (similar to Godrej Topo table or equivalent):Worktop shall be made of combination of 12mm and 6mm thk Corian (matt finish), and 18mm thk Marine ply(BWP Grade)(As per IS:710) with 0.6mm backing laminate on bottom side. Corian shall be composed of acrylic resin and natural minerals that make it a non-porous, non-toxic, water-proof, seam-less and homogeneous surfacing material with resistance to scratches, stains, mould and mildew. The under-structure shall consist of an Inner Tube Assembly with Top Plate, for Worktop Mounting, and an Outer Tube Assembly with Round/Rectangle/Square Bottom Plate. The Inner & Outer Tube Assemblies are to be telescopically connected. The Top Plate shall be made of 5mm thk HOT ROLLED Steel Plates (HR) (As per IS:2062) & the bottom plate shall be made of 8mm thk HOT ROLLED Steel Plates (HR) (As per IS:2062). The Inner Tube Assembly shall be made of 082.5 x 2thk ROUND ELECTRIC RESISTANCE WELDED Tub4 (ERW)(As per IS:7138) and 8mm thk HOT ROLLED Steel Plates (HR) (As per IS:2062) welded together using TUNGSTEN INERT GAS Welding. The Outer Tube Assembly shall be made of 089 x 2.5 thk and ROUND ELECTRIC RESISTANCE WELDED Tubes (ERW)(As per IS:7138) and 8mm thk HOT ROLLED Steel Plates (HR) (As per IS:2062) welded together using TUNGSTEN INERT GAS Welding. The whole structure shall be EPOXY POLYESTER Powder Coated (DFT 40-60 microns). The product shall have a knock-down construction. It shall be assembled using alloy steel hardware (blackened & coated with rust preventive oil)

14

-

-

... More
od309414/2023_2024 : Supply and installing in position Modular Phone Booth for a single person having size 1000x1000x2200 mm of approved made out of acoustic walls as per manufacturer’s specifications internal steel structure and filling with polyurethane sound insulation material, laminated sound proof glass on one side and laminated crystal glass door with automatic shut down using hidden door closers, interior finished with automotive grade sound absorbing felt and sound absorbing carpets and provided with facilities such as a table top with E1 grade pre-laminated surface 25mm thick particle board with D Cut on the back of the table allowing for easy wire access and management, shall have a grade A1 lock set in the door, ergonomic design equipped with universal electrical outlets and USB ports for charging devices and LAN ports for connectivity, ventilation system to ensure the users remain comfortable when inside, with an LED Lighting to ensure the space is optimally lit for notetaking and discussion, a motion sensor which detects when it is being used, and automatically turns on lighting and ventilation. When unused, these features remain off saving energy.

10

-

-

... More
od309417/2023_2024 : Supplying and fixing freestanding modular storage units of approved make and of size 1200x450x750 mm made of 18 mm thick both sides prelaminated particle board for verticals, horizontals and intermediate shelves. The openable door shutters shall be provided with SS handles, locks, auto closing hinges and necessary hardware's etc; complete. The exposed edges shall be finished with 2mm thick PVC lipping etc as per directions of Engineer-in-charge (Warranty period: 5 years)

4

-

-

... More
od309418/2023_2024 : Supplying and fixing freestanding modular storage units of approved make and of size 900x450x1200 mm made of 18 mm thick both sides prelaminated particle board for verticals, horizontals and intermediate shelves. The openable door shutters shall be provided with SS handles, locks, auto closing hinges and necessary hardware's etc; complete. The exposed edges shall be finished with 2mm thick PVC lipping etc as per directions of Engineer-in-charge (Warranty period: 5 years)

1

-

-

... More
od309276/2023_2024 : Supplying and placing in position High Back Chairs with good ergonomic design and<br>adjustable lumbar support, Back and seat with high density PU moulded cushion upholstered with fire<br>retardant Leatherette of approved colour, Gas lift mechanism, adjustable swivel PU Armrest; adjustable head<br>rest, Synchro Tilt Mechanism, base aluminium polished five pronged with twin wheel nylon castors, as per<br>directions of Engineer-in-charge The OEM should have certifications such as BIFMA, ISO, Green guard, AIOTA etc. Test reports from designated AHSP/NABL/ILAC accredited or Central Government Lab to prove conformity of products to the specifications to be furnished if required. Basic cost considered - Rs.20,000.00 (Warranty period: 5 years )

6

-

-

... More
od309277/2023_2024 : Supplying and placing in position High Back Chairs having good ergonomic seat design with synchronic tilt chair mechanism designed with 360 degree revolving type and upright locking and pneumatic height adjustments, 4 position locking, adjustable lumbar support, Back with injection moulded frame and inner frame upholstered with Mesh fabric and mounted on main assembly, push back type, seat pressed and moulded with PU foam 50 mm thick high density 50 kg/cum cushion upholstered with 100% polyester 290 gram GSM, fire retardant fabric of approved colour, adjustable swivel polypropylene Armrest, adjustable head rest, pedestal base glass fiber nylon 650 mm dia five pronged with twin wheel nylon castors 50 mm dia. The chair should have minimum dimensions of overall width 750mm, seat width 500 mm, seat depth 480 mm, back rest width 440 mm (tolerance 10 mm) etc as per directions of Engineer-in-charge The OEM should have certifications such as BIFMA, ISO, Green guard, AIOTA etc. Test reports from designated AHSP/NABL/ILAC accredited or Central Government Lab to prove conformity of products to the specifications to be furnished if required. Basic cost considered - Rs.10,000.00 (Warranty period: 5 years )

1

-

-

... More
od309278/2023_2024 : Supplying and placing in position Medium Back Chairs having good ergonomic seat design with synchronic tilt chair mechanism designed with 360 degree revolving type and upright locking and pneumatic height adjustments, 4 position locking, adjustable lumbar support, Back with injection moulded frame and inner frame upholstered with Mesh fabric and mounted on main assembly, push back type, seat pressed and moulded with PU foam 50 mm thick high density 50 kg/cum cushion upholstered with 100% polyester 290 gram GSM, fire retardant fabric of approved colour, adjustable swivel polypropylene Armrest, pedestal base glass fiber nylon 650 mm dia five pronged with twin wheel nylon castors 50 mm dia. The chair should have minimum dimensions of overall width 670mm, seat width 500 mm, seat depth 480 mm, back rest width 440 mm (tolerance 10 mm) etc as per directions of Engineer-in-charge The OEM should have certifications such as BIFMA, ISO, Green guard, AIOTA etc. Test reports from designated AHSP/NABL/ILAC accredited or Central Government Lab to prove conformity of products to the specifications to be furnished if required. Basic cost considered - Rs.8,000.00 (Warranty period: 5 years )

677

-

-

... More
od309279/2023_2024 : Supplying and placing in position Medium Back Chairs with good ergonomic designand adjustable lumbar support, Back and seat with high density PU moulded cushion upholstered with fireretardant Leatherette of approved colour, Gas lift mechanism, adjustable swivel PU Armrest; adjustable headrest, Synchro Tilt Mechanism, base aluminium polished five pronged with twin wheel nylon castors, as perdirections of Engineer-in-charge Basic cost considered - Rs.15,000.00 (Warranty period: 10 years )

12

-

-

... More
od326493/2023_2024 : Providing, supplying and placing of classroom chair with desklet made up of 1.2±0.1cm thk Plywood upholstered with moulded foam and polyester fabric and covered with an injection-moulded polypropylene outer cover. The seat should tip-up when not in use and while stacking the chairs horizontally The back sub-assembly should be made up of injection-moulded polypropylene inner upholstered with moulded foam and polyester fabric and covered with an injection-moulded polypropylene outer cover. The contoured back with width extension at the bottom should be designed to give comfort to lower back. BACK SIZE: 45.2cm (W) X 44.6cm (H) SEAT SIZE: 47.0cm (W) X 50.0cm (D) The powder-coated 4 leg structure should be made of 2.2 ±0.03cm dia x 0.25 ±0.02cm thk M.S. E.R.W. Tube front and rear leg welded along with connecting tube made of 1.9 ±-0.02cm dia x 0.2 ±0.016cm thk M.S. E.R.W. Tube to form the tubular frame assembly. The legs should be provided with injection-moulded adopter bush in black Nylon and brake-loaded castors enabling easy manoeuvring while not in use and stable sitting while in use_ The chairs can be stacked horizontally when not in use POLYURETHANE FOAM: The Polyurethane foam should be moulded with density = 70.0 ±8.0 kg/m3 and Hardness = 20 ±2 for Seat & 16 ±2 for back at 25% compression. ARMRESTS: The armrest structure should be made up of 2.2 ±0.03crn dia x 0.25 ±0.02cm thk M.S. E R.W. Tube welded to the Tubular Frame structure and having a scratch-resistant tant ABS Arm top. FULL DESKLET: The Full Desklet assembly should be Flip-up type and should be made up of extension tube of 1.9 ±0.02em dia x 0_2 ±0.016cm thk PAS. E.R.W. Tube and a support tube on L.H. side of 1.6 ±0.02cm dia x 0.2 ±0.016cm thk M.S. E.R.W. Tube on which an scratch resistant tant ABS desklet top should be fixed and covered on bottom side with a bottom cover. BRAKE-LOADED CASTORS : The brake-loaded castors should be assembled to the chair legs, to give a free movement for maneuvering the chair when not in use and it will brake the movement when load should be applied (while in use) to give a stable feel. The twin wheel castors should be injection molded in black Polypropylene.

15

-

-

... More
od326485/2023_2024 : Supply and installation of single seater Breakout zone chairs manufactured with solid walnut wood legs and upholstered and padded bent plywood seat, back etc. complete. Warranty – 5 years

15

-

-

... More
od309280/2023_2024 : Supply and installation of Lounge soft seating Single seater with LeatheretteUpholstered seat, seat with PU foam having density 32 kg/m3 +/-2%, poly fiber cushion material, covered with 650 GSM leatherette fabric of color as approved by Engineer-in-charge, supported on four pronged aluminium base (model: Clara/Costa Featherlite make or equivalent) (Warranty - 10 years Manufacturer's certificate to be submitted)

62

-

-

... More
od326494/2023_2024 : Supply and installation of L shaped 5 seater Sofa similar to Featherlite make S series Genesis model or approved equivalent upholstered with fabric etc. complete. Warranty – 5 years

2

-

-

... More
od326495/2023_2024 : Supply and installation of round shaped convex Sofa similar to Featherlite F series Genesis model or approved equivalent upholstered with fabric etc. complete. Warranty – 5 years

16

-

-

... More
od309422/2023_2024 : Supply, fabrication and installation of Laptop Table similar to Featherlite make Brisk /Spiky laptop stand or equivalent Warranty - 5 years

10

-

-

... More
od309281/2023_2024 : Supply and installation of Pouffe seat Cube shape of size H 38.5 x W 41 x D 39 cm made with wooden legs melamine polished and leatherette upholstered seat, seat with PU foam having density 32 kg/m3 +/-2%, covered with 650 GSM leatherette fabric of colour as approved by Engineer-in-charge,

25

-

-

... More
od309282/2023_2024 : Supply and installation of Ottoman seating stool type of size H 45.7 x W 48.3 x D 48.3 cm made with wooden legs melamine polished and leatherette upholstered seat, seat with PU foam having density 32 kg/m3 +/-2% with webbing belt suspension system, poly fiber cushion material, covered with 650 GSM leatherette fabric of color as approved by Engineer-in-charge,

16

-

-

... More
od309283/2023_2024 : Supply and installation of Ottoman seating bench type of size H 45.7 x W 121.9 x D 48.3 cm made with wooden legs melamine polished and leatherette upholstered seat, seat with PU foam having density 32 kg/m3 +/-2% with webbing belt suspension system, poly fiber cushion material, covered with 650 GSM leatherette fabric of color as approved by Engineer-in-charge,

10

-

-

... More
od309284/2023_2024 : Supply and installation of Cafeteria chairs Eames DSW Replica chair of size H 82 x W 46 x D 40.9 cm, sleek and clean seat made of high quality plastic with waterfall edge seat, easy clean surface on Beech wood legs with powder coated metal accent with antiskid buffers and of colour as approved by Engineer-in-charge

88

-

-

... More
od309285/2023_2024 : Supply and installation of Pantry Chairs stackable type with Polypropylene seat and back and four point stainless steel legs as per directions of Engineer-in-charge (Warranty period: 5 years

1

-

-

... More
od309401/2023_2024 : Supply and installation of high seated Cafeteria chairs Eames DSW Replica chair of size H 82 x W 46 cm, sleek and clean seat made of high quality plastic with waterfall edge seat, easy clean surface on Beech wood legs with powder coated metal accent with antiskid buffers and of colour as approved by Engineer-in-charge

60

-

-

... More
od309402/2023_2024 : Supply and installation of wood plastic composite moulded dining chairs tested for 110 kg of width 45 cm, depth 51 cm, height 81 cm, seat width 45 cm, seat depth 41 cm, seat height: 43 cm of approved make and as approved by Engineer-in-charge. (Model: IKEA Odger chair or equivalent)

1

-

-

... More
od301852/2023_2024 : Providing and fixing Reception table made to shape and design as per drawing, of size 1800 x 600 mm and to a height of 750 / 1050 mm, made of 19 mm thick BWP plywood conforming to Is:710 for table top, sides and rear side with adequate supports as directed in both horizontal and vertical directions. The table top to be fixed with Solid Acrylic surface of approved make 12mm thick. The front surface to be provided with 6mm thick Solid Acrylic surface of approved make and 6mm lacquered glass of approved make fixed with 3M double-side tape as per the drawing as per the drawing. All other exposed surfaces of the table shall be finished with 1mm thick laminate of approved make and shade and edges . The table shall be provided with modular mobile pedestal storage unit (3 drawer) of size 450x400x600 mm made out of 18mm thick prelaminated board with locks, telescopic slides, finger groove handle/SS "H' Handles, lockable castors, etc. Table to be provided with accessories such as flip up box for wire management, LED strip lights in Al profile and required drivers in the projections as shown in drawing, powder-coated metal CPU trolley,

7

-

-

... More
od301853/2023_2024 : Providing and fixing Reception table made to shape and design as per drawing, of size 1500 x 600 mm and to a height of 750 / 1050 mm, made of 19 mm thick BWP plywood as table top, sides and rear side with adequate supports as directed in both horizontal and vertical directions. The table top to be fixed with Solid Acrylic surface of approved make 12mm thick. The front surface to be provided with 6mm thick Solid Acrylic surface of approved make and 6mm lacquered glass of approved make fixed with 3M double-side tape as per the drawing as per the drawing. All other exposed surfaces of the table shall be finished with 1mm thick laminate of approved make and shade and edges . The table shall be provided with modular mobile pedestal storage unit (3 drawer) of size 450x400x600 mm made out of 18mm thick prelaminated board with locks, telescopic slides, finger groove handle/SS "H' Handles, lockable castors, etc. Table to be provided with accessories such as fliptop box for wire management, LED strip lights in Al profile as required in the projections as shown in drawing, powder-coated metal CPU trolley, keyboard tray of approved make, , etc. complete and as per directions of Engineer-in-charge.

2

-

-

... More
od309239/2023_2024 : Supply, fabrication and installation of High dining counter 450 mm wide with table top with 15mm thick full body vitrified tiles over PVC sheet/panel 12 mm thick fixed to the under structure with required accessories, screws, clamps, adhesive etc complete. The under structure made of ERW CR Tube 16g thk powder coated with suitable levellers at ends. The edge of the vitrified tile slab table top to be finished by gluing 5 cm wide 15 mm thick slab and edges bull nosed to provide 30 mm thick edges. The quoted rate shall includes the cost of all materials and labours, tools and tackles etc . Measurement will be per rm

30

-

-

... More
od309240/2023_2024 : Providing and fixing in position Cafeteria / Pantry counter with factory finished storage cabinets having shutters , the storage shall be having 600mm depth and 850 mm height. The Counter top shall be with 15mm thick full body vitrified counter slab fixed using suitable adhesive and to include 40x15mm end beading along the outer perimeter of the counter-top. The beading shall have R-5 corner edges along the top and bottom edges. The counter top to be fixed over factory finished support shelf made out of 18mm thick PVC panel finished with 1 mm thick laminate of approved colour and shade , shelf to have openable shutters and exposed faces made out of 18 mm thick super gloss multiwood of approved colour and shade with 2mm edge lipping finish for exposed edgeswith necessary accessories such as soft close hinges, 100mm long brush finish S.S.handles, locks, magnetic catches. Rate to include cutting of counter-top for accommodating the S.S sink and CP fittings and fixing the end beading to the cut-perimeter to neat finish. All the surfaces shall be finished with laminate etc complete as per directions of Engineer-in-charge Note: Only the Front Elevation area shall be considered for Measurement.

19.98

-

-

... More
od309242/2023_2024 : Providing & Fixing Pantry Overhead storage unit of 450mm depth and 600 mm height. The cabinets & shutters shall be FACTORY-FINISHED and made of 18 mm thick super gloss multiwood of approved shade. The storage unit shall include 1 no. of adjustable intermediate shelf as per the drawing made of 18mm thick super gloss multiwood placed on necessary S.S stud supports. The shutters and edges shall be provided with 2 mm thick edge banding of matching shade. Rate to include all hardware, tower bolt, magnetic catch, heavy duty hinges, S.S handles - of approved make, including locking arrangements with master key of approved make etc. complete. Note: Only the Front Elevation area shall be considered for Measurement.

14.1

-

-

... More
od309241/2023_2024 : Providing and Fixing of Storage unit below wash basin counters made of 18mm thick super gloss Multiwood PVC panel of approved make and shade with 1 adjustable 18 mm super gloss PVC panel shelf inside. All exposed surfaces shall be finished with edge banding of matching approved shade. Countertop shall be fixed with 18 mm thick granite of approved colour and including cost of edge moulding, polishing etc complete. Rate to include all hardware, tower bolt, magnetic catch, heavy duty hinges, S.S handles - of approved make, including locking arrangements with master key of approved make etc. complete. Rate to include all hardware, MS brackets for support from the masonry wall, adhesive for fixing granite etc complete. Rate to include cutting of granite counter-top for accommodating the Washbasin bowl and CP fittings, Note: Only the Front Elevation area shall be considered for Measurement.

23.1

-

-

... More
od307224/2023_2024 : Providing and stacking Eugenia narrow leaf plant of height 90 to 120 cm in polybags as per direction of the officer-in-charge

20

-

-

... More
od307225/2023_2024 : 7.71Providing and stacking of Plumeria dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.

10

-

-

... More
od307226/2023_2024 : 5.34Providing and Displaying Zamia palm well developed with fresh & healthy leaves 90 cm ht in 35 cm cement pot as per direction of the officer-in-charge.

50

-

-

... More
od307227/2023_2024 : 3.90Providing and displaying of Spathiphyllum (peace Lilly), having 15 cm to 25 cm ht. blooming stag with fresh & healthy foliage well developed in 15 cm of Earthen pot/plastic pot & as per direction of the officer-in-charge.

50

-

-

... More
od307228/2023_2024 : 3.80Providing and displaying of Rubber plant variegated, well developed, having 45 to 60 cm ht.with fresh, healthy and attractive colorful leaves in 20 cm size Earthen pot/Plastic pot

14

-

-

... More
od307229/2023_2024 : 3.79Providing and displaying of Rubber plant black variety, well developed, having 45 to 60 cm ht.with fresh, healthy and attractive colorful leaves in 25 cm size Earthen pot/Plastic pot as per direction of officer-in-charge.

14

-

-

... More
od307230/2023_2024 : 3.78Providing and displaying of Raphis palm plant, having ht. 1.50 m to 1.65 m with 40 to 50 lush green suckers, well developed, fresh & healthy foliage leaves in 40 cm size of Earthen Pot/Chali/Tray & as per direction of the officer-in-charge.

15

-

-

... More
od307231/2023_2024 : 3.75Providing and displaying of Raphis palm plant, having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed, full of fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

35

-

-

... More
od307232/2023_2024 : 3.70Providing and displaying of Philodendron selloum plant, having ht. 45 cm to 60 cm with 12 to 16 leaves, well developed, fresh and healthy foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

7

-

-

... More
od307233/2023_2024 : 3.58Providing and displaying of Monestaria plant mounted on moss stick 90 cm ht., 2 to 3 plant in one pot well developed with fresh & healthy foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

7

-

-

... More
od307234/2023_2024 : 3.20Providing and displaying of Areca Palm plant, having ht. 1.50 m to 1.80 m with 6 to 8 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

15

-

-

... More
od308365/2023_2024 : Supply and installation at site exterior grade unbreakable high grade polymer pot of size 1200mm dia or nearest size in approved colour as per directions of Engineer-in-charge. Rate shall be inclusive of transportation handling etc complete.

10

-

-

... More
od308366/2023_2024 : Supply and installation at site unbreakable round high grade polymer pot of size 300mm dia or nearest size in approved colour as per directions of Engineer-in-charge. Rate shall be inclusive of transportation handling etc complete.

157

-

-

... More
od308367/2023_2024 : Supply and installation at site unbreakable rectangular high grade polymer pot of size 600x300x300mm or nearest size in approved colour as per directions of Engineer-in-charge. Rate shall be inclusive of transportation handling etc complete.<br>

30

-

-

... More
od308368/2023_2024 : Providing and fixing planter box made with 18mm thick PVC boards (Thomson Multiwood or Century Starke or equivalent) and finished with 1mm laminate of app. design of size 600 mm high x 300 mm wide as per the pattern in the drawings for placing plants as per requirement at site with necessary fasteners and screws etc., all complete as per direction of Engineer-In- Charge. Rate shall be inclusive of all hardware, wastages, etc, complete

70

-

-

... More
od308369/2023_2024 : Supply of Lightweight Expanded Clay Aggregate (LECA) for usage as planting medium as per directions of Engineer-in-charge

100

-

-

... More
od309101/2023_2024 : Making of Vertical garden at site of work, work including fixing of MS square pipe of 50 mm x 50 mm of 12 gauge (1.98 mm strength) thickness (approximate wt. 18 kg/6 mtr pipe) stand horizontally after the gap of 60 cm properly fixed, further supported by rectangular pipe size 50 mm x 25 mm of 12 gauge thickness proper welded vertically with MS square pipe with the regular interval of every 20 cm distance, after making complete frame covered three side with stainless steel chrome plated sheet of 18 gauge (1.02 mm) thickness, 23 cm width in L shape covered two side of the frame and with 30 cm sheet tray in bottom of the frame in U shape i/c cutting moulding and fixing complete , applying antirust paint coat along with further painted black colour paint after completing the frame the vertical module of 53 cm x 17 cm size of R.S. make or equivalent make with 3 no of planter cup of each module complete including proper arrangement of drip irrigation system of each planter cup and connected with pump or water supply line for proper irrigation, after that each planter cup cover by geotextile cloth of 250 gsm in bottom and further fill-up with 1:2 ratio of coco pit with perlite and soil rite mixture complete, planting of plants (Plant Like Money plant variegated/green/marvel Queen Syngonium Red, Marvel Queen or variegated or as per direction of officer in charge) in each planter as per design and pattern approved by authorities and as per direction of officer in charge including cost of materials fitting, filling and other work complete before making the frame the pipe, module, plants and other materials sample approved by officer in charge and maintenance period 30 days free of cost.

12.96

-

-

... More
5.37.2 : Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

17.43

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

12.45

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1394.4

-

-

... More
8.2.2.1 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm

232.4

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

581

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

6764.84

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

140.69

-

-

... More
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

97.99

-

-

... More
13.11 : 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ( 1 cement : 6 fine sand).

703.46

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

803.46

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

100

-

-

... More
13.65.1 : Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new work

100

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.

698.5

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/ Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

1799.3

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

19946.36

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

3068.67

-

-

... More
25.3 : Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement

2159.59

-

-

... More
25.4 : Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.

172.48

-

-

... More
25.5 : Providing,fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi - rigid, inorganic, non- combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5mm and nominal mass not less than 60 gm/ sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts,bolts, washers etc complete.

431.92

-

-

... More
25.6 : Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass panels in the curtain glazing is included in cost of relevent item*). (ii) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face #2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35%, Light reflection internal 10 to 15%, light reflection external 10 to 20%, shading coefficient (0.25 - 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

431.92

-

-

... More
25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

399

-

-

... More
od299608/2023_2024 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with 6 mm thick exterior grade High pressure laminate Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of 6 mm thick exterior grade High Pressure laminates (HPL) panel cladding in colour of approved shades and approved manufacturer as specified as per EN 438-6 type manufactured with norm conformity of EN 438-7 using Non-fading high performance acrylic polyurethane surface Technology double hardened including acrylic polyurethane resin and thermally cured under high pressure, fixed using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with panel cladding, cleaning and protection of the curtain wall till the handing over of the building for occupation. Base frame work for cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with exterior grade High Pressure laminates panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with HPL Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

340

-

-

... More
od303683/2023_2024 : Designing, providing and fixing Semi unitized system with Louver structurally held in position and factory fabricated with Aluminium adaptor of suitable size in order to satisfy the structural design criteria, the system comprising Aluminium anodized extruded frames confirming to IS 8147 and anodizing AC 25 grade confirming to IS 1868 & Adapters supported on the brackets (spanning 3.2 M as maximum), Toggle cleats, HDG brackets & SS anchors and bolts, flashing etc .Rate shall include the cost of Fixed Storm proof Louver - Louver - 75 x 28 x 1.5 mm thick section no 2089 - weight not less than 0.464 Kg/Rmt "Z" type made out of specially extruded aluminium and to be fixed with pitch not less than 50 mm and over lapping shall be 25 mm by using aluminium flat with thickness not less than 2.0mm and flat to be fixed into the aluminium Vertical mullion and Aluminium angle of size 25 x 25 mm alround louver to be provided to protect the system from rain water entry through the sides as minimum. Rate shall also include supply and fixing main frames, plates, L - angle, SS 316 grade fastener & other all accessories, visual mock up and field water test etc. System to be designed to with stand design wind pressure of 150Kg/Sqm confirming to IS 875 part 3 and other load parameters specified.

868

-

-

... More
od299609/2023_2024 : Designing, providing and fixing colour anodized aluminium Swing Door as part of Glazing system and fabricated as per drawing and fixed at all levels, elevations and heights by using aluminium box frame of size 100 x 40 mm and thickness not less than 2.0mm as outer frame and suitable aluminium frames with rebated profile shall be used for Doors with thickness not less than 2.0mm. Aluminium box frame shall be fixed into wall/RC by using SS anchor fasteners of Hilti make or approved equivalent. All glass panels shall be fixed by using snap fit aluminium colour anodized beading with special water proof cascades, Neoprene, hardwares etc. complete, as directed. <br>All aluminium sections shall be 63400 (H9) grade conforming to IS 8147. All aluminium sections shall be finished with exterior grade powder coat of thickness not less than 70 microns and weight ratio joints mitered adjoined with heavy duty aluminium pressure die cast cleats with fins to match the sections of frames.Door shall be provided with necessary hardwares such as Door closer - ITS 96 EN 2 - 4 or TS 91 EN 3 (Opening restrict to 85 deg), Mortise dead lock - Model No. 278 (both side key operation) SS forend and SS strike plate (Suitable for both single / double leaf shutter) of Satin finish - Grade SS 316, SS satin finish handle - TG9377- 25 (Angled Spacer) - 600 mm long with back to back handle SS 316 grade, SS hinges (Minimum 4 Nos / Shutter) SS Door stoppers floor mounted, Door buffers etc. complete and as directed. All Hardwares shall be Dorma / Kinlong / Geze Make.Rate shall include the cost of supplying & fixing 12.52 mm thick laminated glass having 6 mm thick as outer panel and 5 mm thick as inner panel with interlayer of 1.52 mm thick sentry Glas (R) of Dupont make. Outer pane glass shall be reflective coated glass - Inner pane and Outer pane glass shall be uncoated clear glass of Saint Gobain make or Asahi make. Both panes shall be heat treated and heat soak tested. System to be designed to with stand design wind pressure of 150Kg/Sqm confirming to IS 875 part 3 and other load parameters specified in Technical specification.

7.2

-

-

... More
od308971/2023_2024 : Designing, providing and fixing Point fixed glazed Canopy over the M.S base frame with Spiders as per specification (Main frame) to the required size to satisfy the structural criteria as per IS code or relevant international code) to fix the Spider / Articulated bolts of Dorma/Kinlong make. Rate shall include for supplying and fixing of 17.52 mm thick laminated glass having 8 mm thick as outer panel and 8 mm thick as inner panel with interlayer of 1.52 mm thick Sentry Glas (R) plus of Dupont make. Outer pane glass shall be reflective coated glass - Spring (SC60/52) clear of Asahi make or ST 167 Clear of Saint Gobain make. Inner pane of un coated clear glass heat soak tested but both panes shall be heat treated. Rate shall include cost for spiders, Articulated bolts, Bush, PVC clear edge strip for all exposed laminated edges PVC clear edge strip for all exposed laminated edges and necessary scaffolding works to erect the canopy works at all level. But, rate shall exclude the cost of M.S supports to receive the spiders which will be measured under the respective item. System to be designed to with stand design wind pressure of 150Kg/Sqm confirming to IS 875 part 3 and other load parameters specified in Technical specification. Refer Particular Specification item - 22.04 & 22.05, which shall form part of BOQ.

95

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

8400

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

6969.6

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

100

-

-

... More
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

100

-

-

... More
21.1.1.3 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )

1000

-

-

... More
21.14 : Providing and fixing anodised aluminium ( anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular section of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately)

250

-

-

... More
21.17 : Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).

100

-

-

... More
21.19.1 : Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600Upto 5 mm depth and 5 mm width

118

-

-

... More
21.19.2 : Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600Upto 10 mm depth and 10 mm width

100

-

-

... More
od307929/2023_2024 : Designing, fabricating, installing and fixing in position glass railings with 13.52 mm PVB laminated glass with aluminium profile of size 75x62 mm in anodised finish 20-25 microns, made from 6063 T6 grade material, system designed to accommodate 13.52 mm clear PVB laminated glass. The bottom profile shall be securely anchored to the floor using klimas GI hex head anchor M10x100/120 mm with 4 nos/MTR @ 250 mm c/c and the glass shall be affixed to the bottom profile with high grade POM shims, 4 nos per meter. Top aluminium structural handrail fixing at top edge of glass shall be with help of POM shims, 4 nos per meter and an EDPM gasket to be used to seal and secure the aluminium handrail of size 39x37 mm in anodised finish 20 - 25 micron. Measurement shall be per sqm of face area.

58.08

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.