Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 31,300Document Cost
₹ 2,500Tender Fee
Refer Documents
Summary
Opd Transformation In Nmch Block- Supply, Installation, Testing , Commisioning Of Vrf Duct Air Conditioning System At Surgery Op
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_KSHB_435546_1Bid Award Id
ViewTender No
EE/KKD/1/2021-22Tender Authority
Kerala State Housing Board ViewPurchaser Address
-Website
http://http://www.kshb.kerala.gov.in/kshb/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
od79224/2021_2022 : INDOOR UNIT-DUCTABLE TYPE- High Static Ductable units (minimum 110 pascal external static pressure)<br>Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230V±10%,50Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 8 TR (unit in TR)<br><br>
1
-
-
... More
OUT DOOR UNIT
-
-
-
... More
od79225/2021_2022 : Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Out door units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s),minimum two compressors for above 20 HP modules, microprocessor based Controller, top discharge type condensing unit(s),withR410A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V+/-10%,3 Phase, 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5)Cost for 1 Hp Capacity
20
-
-
... More
COPEER REFRIGERANT PIPING
-
-
-
... More
od81636/2021_2022 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required<br>28.58 mm dia(OD)(Hard drawn)with tube thickness1.2mm with19mm thick insulation<br>
14
-
-
... More
od81637/2021_2022 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required<br>22.2 mm dia(OD)(Hard drawn)with tube thickness1.2 mm with19mm thick insulation<br>
14
-
-
... More
od81638/2021_2022 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required<br>19 mm dia(OD)(Hard drawn)with tube thickness1.2 mm with19 mm thick insulation<br>
14
-
-
... More
od81639/2021_2022 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required<br>15.86 mm dia(OD)(Soft drawn)with tube thickness1.2 mm with19mm thick insulation<br>
14
-
-
... More
od81640/2021_2022 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required<br>12.7mm dia (OD)(Soft drawn)with tube thickness1.2 mm with 19mm thick insulation<br>
14
-
-
... More
od81641/2021_2022 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required<br>9.5mmdia(OD)(Soft drawn)with tube thickness 1.2mm with19mm thick insulation<br>
14
-
-
... More
od81642/2021_2022 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required<br>6.4mmdia(OD)(Soft drawn)withtubethickness1.2mmwith19mmthick insulation<br>
14
-
-
... More
BRANCH JOINTS
-
-
-
... More
od81644/2021_2022 : SITC of Refnet Joints and Headers Shall be used for interconnection between indoor and outdoor units. Shall be selected by the supplier depending on the machine configuration. Number of joints shall be minimized and optimized to suit system performance.Branch Joints
2
-
-
... More
COMMUNICATION CABLING
-
-
-
... More
od81645/2021_2022 : Supply and Installing of Communication cabling with 25 mm PVC Medium class conduit between indoor and outdoor unit as per unit requirement<br>
104
-
-
... More
DRAIN PIPING
-
-
-
... More
od81646/2021_2022 : SITC of condensate drain UPVC / CPVC piping as per IS 4985 (10kg/cm2) with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc. duly insulated with 9 mm thick nitrile rubber insulation with flexible woven glass fibre cloth covering, fire retardant grade as per the drawing and relevant standards.32mm Dia
10
-
-
... More
od81647/2021_2022 : SITC of condensate drain UPVC / CPVC piping as per IS 4985 (10kg/cm2) with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc. duly insulated with 9 mm thick nitrile rubber insulation with flexible woven glass fibre cloth covering, fire retardant grade as per the drawing and relevant standards.40mm Dia
10
-
-
... More
od81648/2021_2022 : SITC of condensate drain UPVC / CPVC piping as per IS 4985 (10kg/cm2) with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc. duly insulated with 9 mm thick nitrile rubber insulation with flexible woven glass fiber cloth covering, fire retardant grade as per the drawing and relevant standards.50mm Dia
10
-
-
... More
CABLE TRY
-
-
-
... More
od81649/2021_2022 : Supply, Conveyance, installing of Suitable Cable tray for running copper pipe and cables between indoor and outdoor units<br>
48
-
-
... More
GSS DUCT WORK
-
-
-
... More
od81651/2021_2022 : Supply & Installation of Duct work Insulation- Closed cell elastomeric insulation of specific thickness, inline with the specifications, drawings etc Supply and fresh air duct work complete, running in Air-Conditioned space.<br>(19 mm thick)
115
-
-
... More
od81652/2021_2022 : Supply and Fixing of Canvass connection between Ceiling concealed indoor units and GSS Duct
2
-
-
... More
od81653/2021_2022 : Supply & Installation of GSS duct work with all accessories, supports, jointing materials, flanges complete all inline with the specifications, drawings etc Supply and Fresh Air duct work complete (24 Gauge)
85
-
-
... More
od81654/2021_2022 : Supply & Installation of GSS duct work with all accessories, supports, jointing materials, flanges complete all inline with the specifications, drawings etc Supply and Fresh Air duct work complete (22 Gauge)
50
-
-
... More
ACCOUSTIC INSULATION
-
-
-
... More
od81655/2021_2022 : Supply and installation of Underdeck insulation,75mm thick EPS slab TF quality having density of 24 KG/m3 using necessary SS wires, SS washers, adhesive etc.19mm Nitrile Rubber
1
-
-
... More
od81656/2021_2022 : Supply & Installation of Acoustic Insulation using nitrile rubber, open cell foam, fiber free, minimum density of 140 kg/cu.m should have microban, as per ASTM G-21, ASTM E-2180, thermal conductivity not exceeding 0.047 W/m.K at 20 C, conform to class 1 rating for flame spread in accordance to PS 476 part 7, to thickness of minimum of 10mm all inline with the specification and to meet the design noice criteria.Acoustic liner
40
-
-
... More
GRILLS/DIFFUSER
-
-
-
... More
od81659/2021_2022 : Supply & Installation of Grilles / Diffusers Return Air Square 2 way Grills / 4 way Diffusers
8
-
-
... More
od81660/2021_2022 : Supply & Installation of Grilles / Diffusers Supply Air Square 2 way Grills / 4 way Diffusers
5.5
-
-
... More
DAMPERS
-
-
-
... More
od81683/2021_2022 : Supply & Installation of Fire dampers as specified Fire dampers
0.1
-
-
... More
od81684/2021_2022 : Supply & Installation of Volume Control Dampers as specified Volume Control dampers in duct work air distribution and extract systems to regulate airflow and balancing the air systems to adequately balance whether or not, these are indicated on the drawings.