Kerala State Film Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Film Development Corporation Limited - KSFDC Tender

Eprocure
Opening Date5 Jun 2021
Closing DateCancelled
Tender Amount₹ 11,59,41,186 
Notes
Download

Costs

Summary

Construction Of Theater Complex At Perambra (retender)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

750

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

4

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

4

-

-

... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

3

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

87.14

-

-

... More
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

203.31

-

-

... More
od149306/2018_2019 : Earth work in excavation by means (Hydraulic excavator/manual means) in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, for lift of 1.5m to 3.00m, including getting out the excavated soil and disposal/stacking of surplus excavated soil within the site as directed by the Engineer- in-Charge.Hard rock (blasting prohibited)

6.3

-

-

... More
od149307/2018_2019: Earth work in excavation by means (Hydraulic excavator/manual means) in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, for lift of 1.5m to 3.00m, including getting out the excavated soil and disposal/stacking of surplus excavated soil within the site as directed by the Engineer- in-Charge.Ordinary rock.

22.03

-

-

... More
od149309/2018_2019: Earth work in excavation by means (Hydraulic excavator/manual means) in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, for lift of 1.5m to 3.00m, including getting out the excavated soil and disposal/stacking of surplus excavated soil within the site as directed by the Engineer- in-Charge.All kinds of soil.

3.15

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

453.11

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

763.7

-

-

... More
2.7.3 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited

98

-

-

... More
od22166/2018_2019 : Earth work in excavation by means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including disposal/stacking of excavated earth, lead upto 50 m and for lift from 1.5m to 3.00m; disposed earth to be levelled and neatly dressed, as directed by the Engineer- in-Charge. Hard rock (blasting prohibited)

151.1

-

-

... More
od22167/2018_2019 : Earth work in excavation by means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including disposal/stacking of excavated earth, lead upto 50 m and for lift from 1.5m to 3.00m; disposed earth to be levelled and neatly dressed, as directed by the Engineer- in-Charge.Ordinary rock.

538.2

-

-

... More
od22168/2018_2019 : Earth work in excavation by means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including disposal/stacking of excavated earth, lead upto 50 m and for lift from 1.5m to 3.00m; disposed earth to be levelled and neatly dressed, as directed by the Engineer- in-Charge.All kinds of soil

137.6

-

-

... More
od22171/2018_2019 : Earth work in excavation by means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including disposal/stacking of excavated earth, lead upto 50 m and for lift from 3.00m to 4.5m; disposed earth to be levelled and neatly dressed, as directed by the Engineer- in-Charge.Hard rock (blasting prohibited)

22.2

-

-

... More
od22172/2018_2019 : Earth work in excavation by means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including disposal/stacking of excavated earth, lead upto 50 m and for lift from 3.00m to 4.5m; disposed earth to be levelled and neatly dressed, as directed by the Engineer- in-Charge.Ordinary rock

177.3

-

-

... More
od22173/2018_2019 : Earth work in excavation by means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including disposal/stacking of excavated earth, lead upto 50 m and for lift from 3.00m to 4.5m; disposed earth to be levelled and neatly dressed, as directed by the Engineer- in-Charge.All kinds of soil.

22.2

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

1681.3

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

185.7

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

2327.8

-

-

... More
50.2.3.1 :Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete

64

-

-

... More
CONCRETE WORK

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

162.9

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

48.8

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1.5

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

1656.9

-

-

... More
4.13 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

48.8

-

-

... More
RCC WORK

-

-

-

... More
od32643/2018_2019 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level

544.7

-

-

... More
od32644/2018_2019 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum.All work above plinth level upto floor V level

860.8

-

-

... More
od22184/2018_2019 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.

14.6

-

-

... More
Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

186.3

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

63078.8

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

125216.9

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

529.2

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1825.8

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

2413.8

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

3360.9

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1548.4

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

267

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

549

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

40.4

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

1946.3

-

-

... More
MASONRY WORK

-

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

79.8

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

35.1

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

317.9

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

305.7

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

20.2

-

-

... More
od22314/2018_2019 : Solid block masonry using pre cast sold blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part 1 of 1979 for Super structure above floor two level upto floor five level for 10 cm thick wall in: Cm 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete.

44.3

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

635.2

-

-

... More
JOINERY WORK

-

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

3525.8

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

193.7

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

24.1

-

-

... More
21.15.1 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Anodized (AC 15 ) aluminium

38

-

-

... More
od142477/2018_2019 : Supply and installation of 12 mm clear toughened glass door using Patch fittings, Floor Spring , Door Handle & Lock, sealant and all other fasteners.Glass and fittings shall be of approved make. Cost shall be including all labour, lead,lift, fabrication charges, cost of all consumables, etc as directed by Engineer in charge .Glass shall be heat soaked.

14.4

-

-

... More
od142472/2018_2019 : Design, supply and installation of spider glazing as per architectural drawings with minimum 12mm clear toughened glass using Spiders , fixed bolts, Bushes of approved make, necessary sealant and all other fasteners which confirm to wind load and static load calculations to form grids. Cost shall be including all labour, lead, fabrication charges, cost of all consumables,fittings etc as directed by the Engineer in charge.All fittings shall be of SS 316 grade and Fabrication drawing including design calculation shall be submitted and got approved prior to the execution

47.7

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

4

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.7

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

45.6

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

96

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

20

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

14

-

-

... More
9.92.1 : Providing and fixing chromium plated brass handles with necessary screws etc. complete:125 mm

12

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

24

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

16

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suitable for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

86

-

-

... More
od33780/2018_2019 : Providing and fixing IS : 12817 marked stainless steel ball bearing hinges (heavy weight) with stainless steel screws etc. complete: 100x89x3 mm

60

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

6.4

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of 37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

19.1

-

-

... More
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete - 125 mm

15

-

-

... More
14.70 : Melamine polishing on wood work ( one or more coat)

109.4

-

-

... More
od25723/2018_2019 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item) With Toughened glass 12 mm thickness

13.2

-

-

... More
od25725/2018_2019 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):Pin headed glass.With pin headed glass panes of 4.0 mm thickness

1.8

-

-

... More
od25753/2018_2019 : Supplying and fixing rolling shutters of approved make,made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S top cover of required thickness for rolling shutters including two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, including cost and conveyance of all materials, labour charges,lead,lift etc complete as directed by Engineer in Charge at all levels. 80 X 1.25 mm M.S.Laths with 1.25mm thick top cover

12

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

5

-

-

... More
od30985/2018_2019 : Providing and fixing 12 mm compact laminate, floor mounted Modular Toilet cubicles of approved size , make and Model . Approximate size of cubicle 1550mm(W) X1775 mm(D) X 2003mm(H) including bottom gap of 150 mm and approximate door size 610mm (W) X 1750mm (H) using 12 mm thick Compact Laminate of approved colour and finish,SS Shoe legs as per manufacturer specifications, SS Gravity hinges (Right /Left) ,SS Coat Hook with door Stopper,SS Door Knob, SS Lockset with indicator, Aluminium U and F channel , SS Screws & Wall Plugs etc.The rate is Inclusive of cost,carriage of all materials, labour charge, lead & lift etc complete as directed by Engineer-in-Charge at all levels. The rate includes cutting the sharp edges of compact laminate with specialised machinery,additional frame work for suit the ledge wall etc,cutting and making good the wall/floor etc wherever required .The above work shall be carried out by an agency having sufficient experience in executing similar work and only skilled and experienced persons shall be employed for this purpose.

8

-

-

... More
od142197/2018_2019 : Providing and fixing hinged handicaped toilet door of HPL Board Merino Design/Green Sturdo Classique- Grandeur of greenply or equivalent in single colour, 12mm thick compact laminate of size 1050mmX 2100mm including providing of all accessories like SS Door Frames,D-Post door channel, Gravity hinges, privacy thumb turn c/w occupancy indicator, coat hook, door knob, rubber door stopper lining and screws & wall etc complete. The rate is inclusive of all hardware labour charges ,carriage and lead & lift etc. Complete as directed by Engineer in Charge.

1

-

-

... More
od36490/2018_2019 : Design, supply & installation of Spider Glazing system including SS 316 grade hanging string for roofing work designed to withstand the wind pressure with 12mm thick toughened glass using Spiders fixed bolts, Bushes of approved make, assembly over existing steel structure of roof to a maximum span upto 4.00 m . The rate shall include all design, Engineering and shop drawing, labour, scaffolding, other incidental charges including wastage, fasteners, anchor bolts. all complete as directed by the Engineer in charge at all levels. Fabrication drawing including design calculation shall be submitted to Engineer in Charge and got approved prior to the execution.

27.2

-

-

... More
od142494/2018_2019 : Supplying And Fixing Hook Lock Glass to Glass for Frameless glass double door with 60mm EPC - both side key of approved make , all complete as per approved drawings and as directed by Engineer in Charge.

3

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

48

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

10.8

-

-

... More
9.74.4 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:100x10 mm

20

-

-

... More
Supplying And Fixing fire rated Mortise Lockcase and Cylinder of approved quality for fire rated steel doors , all complete as directed by Engineer in Charge.

15

-

-

... More
Supplying And Fixing a pair of fire rated Solid SS Lever Handle of approved size and quality for fire rated steel doors , all complete as directed by Engineer in Charge.

15

-

-

... More
PARTITION WORK

-

-

-

... More
od32187/2018_2019 :Supply and installation of false ceiling using fibre cement board of approved make of thickness 8 mm and dimension 1220 mm x 2440 mm at all height including fixing on GI section 45 x 15 x 0.9 mm running at spacing of 1000 mm centre to centre, to which this ceiling section having thickness of 10.5 mm , at 450 mm centre to centre , shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre , with 25 mm long dry wall screws @230 mm interval etc complete as per manufacture's specification at all level as per the direction of Engineer in charge

50

-

-

... More
od32188/2018_2019 : Providing & fixing 8 mm thick (exterior grade) wooden textured cement fibre board panels in required profile over existing wall / Aluminium frame work to a height up to 18 m using brass screws and additional adhesive for extra caution. (Aluminium frame work will be measured and paid separately under relevant items) .Cement fibre board shall be finished with 2 or more coats of acrylic smooth exterior paint of approved shade over a priming coat of exterior primer.Screw heads shall match the same finish and colour of the board with putty and paint / powder coating .The rate shall include cost and conveyance of all materials , labour , scaffolding ,lead ,lift etc complete at all levels as directed by the Engineer- in-Charge .(Painting over pre finished wooden textures surface will be measured and paid separately under relevant items)

161.3

-

-

... More
od32189/2018_2019 : Providing & fixing 8 mm thick (exterior grade) cement fibre board panels in required profile over existing wall / Aluminium framework to a height up to 20 m using brass crews and additional adhesive for extra caution . (Aluminium framework will be measured and paid separately under relevant items) . Cement fibre board shall be finished with 2 or more coats of emulsion paint of approved shade over 2 coats of cement primer . Screw heads shall match the same finish and colour of the board with putty and paint /powder coating. The rate shall include cost and conveyance of all materials ,labour,scaffolding ,lead ,lift etc complete at all levels as directed by the Engineer- in-Charge .(Painting will be measured and paid separately under relevant items)

280.5

-

-

... More
od32932/2018_2019 : Providing & fixing interior grade high pressure compact laminate of 6mm thickness conforming to IS:2046-1995 over existing grade ply for column and wall cladding using adhesives /double sided tapes .Grooves finished with 10x10mm PVDF coated Aluminium" U" channel of approved size and colour.The rate shall include cost and conveyance of all materials,cutting , polishing, making grooves, cutout for DB doors etc.10mm x10mm size PVDF coated Aluminium "U" Channel in specified joints , labour charges, lead, lift ,scaffolding,etc complete as per drawing and as directed by Engineer-in-Charge at all levels.Wood grain with suede finish.

20.3

-

-

... More
od32933/2018_2019 : Providing & fixing 12 mm thick BWP grade ply confirming to IS- 710 on existing Aluminum/ply frame work or column , wall cladding,ceiling and partition works,framework using 20mm or approved size SS 304 grade screws at every 600 mm center to center . The rate shall include the cost & conveyance of all materials, labour charges, lead, lift , cutting any shapes , provisions for electrical & networking fixtures, hinges, touch latch system, wherever required, ,etc complete as directed by Engineer-in-Charge at all levels.

20.3

-

-

... More
STEEL WORK

-

-

-

... More
od22321/2018_2019 : Steel work for Truss work,frames etc in built up tubular sections YST 310 grade as per IS: 4923 including cutting, bending, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes including painting with two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, closing all the open ends properly with same material ,cost and conveyance of all materials, labour, etc., complete as directed by the Engineer-in-Charge at all levels.

43650.6

-

-

... More
od22325/2018_2019 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In gratings, frames, guard bar, ladders, railings, brackets, gates &similar works.

15271.5

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

1723.6

-

-

... More
od31086/2018_2019 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, scaffolding, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In stringers, treads, landings etc of staircases including use of chequered plate wherever required, all complete

442.8

-

-

... More
od31482/2018_2019 : Providing and fixing stainless steel (Grade 304) glass railing of 1.2m height, made of toughenedglass(12mm thick), Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing andfitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing withnecessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on thetop of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.:For open terrace portion

5

-

-

... More
od32818/2018_2019 : Structural steel work welded in single sections,trussess and framed work including cutting, hoisting, fixing in position and applying two coats of Synthetic enamel paint over two coats of anticorrossive Yellow zinc chromate primer including cost and conveyance of all materials,labour charges ,lead,lift etc complete as directed by Engineer in Charge at all levels.

1877.7

-

-

... More
16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade

43.2

-

-

... More
FLOORING WORK

-

-

-

... More
od33921/2018_2019 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications etc including cost and conveyance of all materials,cement slurry,labour charges ,lead,lift etc complete as directed by Engineer in Charge at all levels.

317.9

-

-

... More
11.6.1 : Cement plaster skirting of 18 mm thick upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .

69.8

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

44.4

-

-

... More
od36417/2018_2019 : Providing and laying Anti-skid Ceramic floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

63.2

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

868

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

72.8

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

66.2

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

567.2

-

-

... More
8.12 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge.a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

445.1

-

-

... More
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

102.5

-

-

... More
od25842/2018_2019 : Supplying and fixing cement bonded particle board of thickness 20 mm over already laid steel frame work with self drilling screws to form raised false flooring as per approved drawings .The rate shall include cost and conveyance of all materials, labour charges etc. complete for all levels and as directed by the Engineer-in-Charge.

525.9

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

8

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

74.9

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

15.7

-

-

... More
ROOFING,FACADE & FALSE CEILING WORK

-

-

-

... More
25.8 : Design supply & installation of suspended Spider Glazing system designed towithstand the wind pressure as per IS 875 (Part-III). The Suspended Systemheld with Spider Fittings of SS-316 Grade Steel of approved manufacturer withglass panel having 12 mm thick clear toughened glass held together withSS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins21 mm thick. The Glass fins and glass panel assembly shall be connected toSlab/beams by means of SS- 316 Grade stainless steel brackets & Anchor boltsand at the bottom using SS channel of 50x25x2mm using fastener & anchorbolts, non staining weather sealants of approved make, Teflon/ nylon bushesand separators to prevent bi-metallic contacts, all complete to perform as perspecification and approved drawings. The complete system to be designed toaccommodate thermal expansion & seismic movements etc. The joints betweenglass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assemblyto be filled with non staining weather sealant, so as to make the entire systemfully water proof & dust proof.The rate shall include all design, Engineering and shop drawing includingapproval from structural designer, labour, T&P, scaffolding, other incidentalcharges including wastage, enabling temporary services all fitting fixers nutbolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc.all complete. For the purpose of payment, actual elevation area of Glazingincluding thickness of joints and the portion of Glass panel inside the SS channelshall be measured.

170.8

-

-

... More
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board

884.3

-

-

... More
12.45.4 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.

611.5

-

-

... More
od25850/2018_2019 : Design, supply and fixing of PUF Panel in 50mm thick, made out of 0.50mm TCT 300Mpa 150GSM (AZ 150) colour coated Profiled galvalume/zincalume sheets of approved colour (34.5mm crest height in 333.3mm pitch) on the top and 0.50mm TCT 300Mpa 150GSM colour coated galvalume/zincalume slightly ribbed sheet at the bottom with Polyurethane Foam insulation as infill. The colour coating on sheet shall have a total coating thickness of 35 micron comprising of 20 micron Silicon Modified Polyester Paint system of approved colour on the top and 5 micron back up epoxy coating at the bottom over 5 micron primer coating on both sides. The infill insulation material (PUF) shall be fire retardant self extinguishing CFC/HCFC Free and Zero ODP (Ozone Depletion Potential). Polyurethane Foam shall have a density of 40 + 2Kg/M3 in 50mm thick (50 mm + 34.5mm at crest) injected in between the top & bottom sheet using a special foaming machine. The panels will be supplied in 1023mm supply width (1mtr effective width) and length can be as per the site requirement up to a maximum of 12mtr. The panel shall be manufactured from a continuous panel manufacturing line using pentane as blowing agent. The panel shall be directly fixed to the purlins with galvanized imported self drilling and self tapping fasteners with EPDM washers. All the joints will be sealed with sealants and stitched with stitching screws wherever necessary, all complete as per technical specification and as directed by the Engineer-In-Charge.

665.8

-

-

... More
12.14 : Providing flat iron brackets 50x3 mm size with necessary bolts, nuts and washers etc. for fixing asbestos cement / G.S. sheet gutters with purlins.

66.6

-

-

... More
od25852/2018_2019 : Providing and fixing Gutter ( excluding gutter support) in required width (upto a maximum of 1200mm girth) with plain galvalume/zincalume colour coated sheet made out of 0.5mm TCT, minimum 300 MPa cold rolled steel with hot dip metallic coating of Aluminium Zinc alloy (Galvalume/zincalume) 150 gms/sqm,total of both sides, AZ 150 as per ASTM A 792 or AS1397, with polyester colour coating including cost and conveyance of all materials, scaffolding, lead,lift, labour charges etc. complete at all levels as directed by Engineer-in-Charge

66.6

-

-

... More
od127419/2018_2019 : Providing and fixing ridge/ valley capping/flashing in required width (upto maximum 600 mm) with plain galvalume/zincalume colour coated sheet made out of 0.50mm TCT, minimum 300 MPa cold rolled steel with hot dip metallic coating of Aluminium Zinc alloy (Galvalume/zincalume) 150 gms/sqm,total of both sides, AZ 150 as per ASTM A 792 or AS1397, with polyester colour coating including cost and conveyance of all materials, scaffolding, lead,lift, labour charges etc. complete at all levels as directed by Engineer-in-Charge

144.1

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account).

592.2

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing (with open joints) for linear as well ascurvilinear portions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings for the specifieddesign loads conforming to IS 875 part III (the system must passed the proof testat 1.5 times design wind pressure without any failure), including functional designof the aluminum sections for fixing glazing panels of various thicknesses, aluminiumcleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clampsetc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmokeseals, microwave cured EPDM gaskets for water tightness, pressureequalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3Dimentional movement for achieving perfect verticality and fixing structural glazingsystem rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetalliccontacts with nuts and washers etc. of stainless steel grade 316, of the requiredcapacity and in required numbers.c) Providing and filling, two part pump filled, structural silicone sealant and onepart weather silicone sealant compatible with the structural silicone sealant ofrequired bite size in a clean and controlled factory / work shop environment ,including double sided spacer tape, setting blocks and backer rod, all of approvedgrade, brand and manufacture, as per the approved sealant design, within and allaround the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thickand of sizes, shapes and profiles, as required as per the site conditions, to seal thegap between the building structure and all its interfaces with curtain glazing tomake it watertight.e) Making provision for drainage of moisture/ water that enters the curtain glazingsystem to make it watertight, by incorporating principles of pressure equalization,providing suitable gutter profiles at bottom (if required), making necessary holesof required sizes and of required numbers etc. complete. This item includes costof all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges includingwastages etc., enabling temporary structures and services, cranes or cradles etc.as described above and as specified. The item includes the cost of getting all thestructural and functional design including shop drawings checked by a structuraldesigner, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of theindividual components for testing in an approved laboratory, field tests on theassembled working structural glazing as specified, cleaning and protection till thehanding over of the building for occupation. In the end, the Contractor shall providea water tight structural glazing having all the performance characteristics etc. allcomplete as required, as per the Architectural drawings, as per item description,as specified, as per the approved shop drawings and as directed by the Engineerin-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extrudedaluminium section capping for fixing in the grooves of the curtain glazing andvermin proof stainless steel wire mesh shall be paid for separately under relevantitems under this sub-head. However, for the purpose of payment, only the actualarea of structural glazing (including width of grooves ) on the external face shallbe measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazingsystem if area of structural glazing exceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board for Testing and CalibrationLaboratories), Department of Science & Technologies, India. Cost of testing ispayable separately. The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing systemTests to be conducted in the NBL Certified laboratories1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to+300pa) as perASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testingmethod for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testingmethod for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testingmethod for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method forQualitative test” Tests to be conducted on site6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)upto 2000ml”

59.2

-

-

... More
25.3 : Providing, assembling and supplying vision glass panels (IGUs) comprising ofhermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel unitsof size and shape as required and specified, comprising of an outer heatstrengthened float glass 6mm thick, of approved colour and shade with reflectivesoft coating on surface # 2 of approved colour and shade, an inner Heat strengthnedclear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primaryseal and secondary seal (structural silicone sealant) etc. all complete for the requiredperformances, as per the Architectural drawings, as per the approved shopdrawings, as specified and as directed by the Engineer-in-Charge. The IGUs shallbe assembled in the factory/ workshop of the glass processor. (Payment for fixingof IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment,only the actual area of glass on face # 1 of the glass panels (excluding the areas ofthe grooves and weather silicone sealant) provided and fixed in position, shall bemeasured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating onface # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved makehaving properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflectioninternal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performanceglass shall be decided by technical sanctioning authority as per the site requirement

48.7

-

-

... More
25.5 : Providing,fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi - rigid, inorganic, non- combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5mm and nominal mass not less than 60 gm/ sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts,bolts, washers etc complete.

10.5

-

-

... More
25.4 : Extra for openable side / top hung vision glass panels (IGUs) including providingand supplying at site all accessories and hardwares for the openable panels asspecified and of the approved make such as heavy duty stainless steel frictionhinges, min 4 -point cremone locking sets with stainless steel plates, handles,buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts,washers etc. all complete as per the Architectural drawings, as per the approvedshop drawings, as specified and as directed by the Engineer-in-Charge.

5.9

-

-

... More
25.6 : Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass panels in the curtain glazing is included in cost of item No. 25.2).(ii) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face #2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35%, Light reflection internal 10 to 15%, light reflection external 10 to 20%, shading coefficient (0.25 - 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

10.5

-

-

... More
FINISHING WORK

-

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

10077.3

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

2886.6

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

328.6

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

2003.4

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

15087.8

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

3010

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

9132.6

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

5319

-

-

... More
13.10 : 15 mm cement plaster 1:3 ( 1 cement :3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.

1692

-

-

... More
13.45.1 : Finishing walls with textured exterior paint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

28.1

-

-

... More
13.42 : Distempering with 1st quality acrylic distemper (ready mixed) of approvedmanufacturer, of required shade and colour complete, as per manufacturer'sspecification.

18.8

-

-

... More
13.40 :Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:

104.6

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

617.3

-

-

... More
MISCELLANEOUS BUILDING WORK

-

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be appliedas intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5mm thickness after scrapping and properly cleaning the surface to remove looseparticles from the plaster surface, followed by top coating with Premium AcrylicSmooth exterior paint with Silicone additives of required shade by two or morecoats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

300.2

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

629

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction ofEngineer-in-Charge.

258.9

-

-

... More
od36492/2018_2019 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight<br>of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

4

-

-

... More
Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weightbrof the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

10

-

-

... More
Providing and applying 2 coats an acrylic polymer modified elastomeric cementitious water proof coating on roof slab , gutter ,OHT,SUMP,Retaining wall etc which shall be mixed as per manufacture's technical specification, after thoroughly cleaning the surface by mechanical means to making it free of any loose mortar,unsound substrate,"V" grooves cut along the construction joints, cracks and joints of slab/wall on the external face and the same shall be filled with polymermodified mortar( CM 1:3 mixed with approved water proofingbrcompound in the proportion recommended by the manufacturers), cracks in the slab (if any), pressure grouting wherever necessary by injecting mixed with approved expanding agent using pressure grouting pump with a pressure of 3 to 4kg/sqm ,strictly maintaining the coverage specified by the manufacturer, including cost and conveyance of all materials,labour charges etc complete as directed by the Engineerin- Charge .(The above work shall be carriedout by an agency having sufficient experience in membrane water proofing and should ensure a guarantee of 5 years. .Only skilled and experienced persons shall be employed for this purpose.)

748.8

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

318.8

-

-

... More
Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge - 110mm OD(6 kg/cm2)

15

-

-

... More
Providing and constructing soak pit 1.5 m x 1.5 m x 1.5 m size with honey comb brick work on the sides upto a height of 0.9m and brick masonry in CM 1:6 for the balance height, providing and filling brick bats graded, upto a height of 1.2 m, providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials, labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

1

-

-

... More
Providing and laying PVC membrane waterproofing system in horizontal plane including adjustment layer to take up any surface irregularities of the substrate, in order to avoid any imperfections or foreign particles damaging the waterproof layer. It shalll composed of geotextile, weight of 300 g/m2, laid in dry conditions with edge overlap of 10/15 cm. Synthetic membrane of plasticized PVC, 2mm thick of approved manufactor shall conform to the physical and chemical properties such as: Elongation at break (300%) UNI EN ISO 527-3 or equivalent, Ultimate Tensile Strength ( 16.7 N/mm²), Puncture resistance ( 1100mm) DIN 16726-5.12 or equivalent, Hydrostatic pressure Waterproof UNI EN 1928 resistance (6 hours at 5 bar) or equivalent. Double seam welding of PVC waterproofing membrane joints pressure tested to 2 bars of 10 minutes the waterproofing project to be divided into sectors if required and it is composed of shaped joints of PVC and it is welded to the existing waterproof liner.brThe rate shall be inclusive of providing and laying protection layer of non-woven 300gsm geo-textile membrane over the laid PVC waterproof membrane system, followed by a cement mortar screed of 50mm thick over the top layer of geo-textile membrane to facilitate the placing and tying of reinforcement bars of raft and all pressure release mechanism etc complete as directed by the Engineer-In-Charge.

232.6

-

-

... More
Providing and Iaying PVC membrane waterproofing system over the vertical side for retaining wall. Installing geotextile of 300gsm as correction layer, over the vertical side of the wall, before installation PVC membrane 2mm thick of approved manufactor shall conform to the physical and chemical properties such as: Elongation at break (300%) UNI EN ISO 527-3 or equivalent, Ultimate Tensile Strength ( 16.7 N/mm²), Puncture resistance ( 1100mm) DIN 16726-5.12 or equivalent, Hydrostatic pressure Waterproof UNI EN 1928 resistance (6 hours at 5 bar) or equivalent on vertical side, providing and fixing suitable arrangement for fixing mechanically onto the vertical wall to hold the membrane in vertical position against sagging due to self weight of the membrane and without damaging the PVC membrane and providing and Installing 2mm thick synthetic membrane of plasticized PVC with double seam welding of PVC waterproofing membrane joints and pressure testing of the same to 2 bars up to 10 minutes and with compartmentalization by welding PVC water stop with welding fins at all construction joints and at strategic locations to make a compartment of 200 sqmtrs pre installed with required number of injection flanges in every compartment fitted with inlet / outlet pipe and surface access box. brThe cost shall include the cost for providing and Installing a minimum protection layer of 300gsm or 25mm thick EPS protection boards over the vertically installed PVC waterproofing membrane, on the vertical face of the retaining wall to act as a protection layer against backfill and all pressure release mechanism etc complete as directed by the Engineer In Charge.

213.3

-

-

... More
od31853/2018_2019 : Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )

310

-

-

... More
od31875/2018_2019 : Providing and fixing Queue manager posts(2 end posts) in stainless steel 304 grade having height 910mm and base diameter 320 mm with tube of 63.5 mm diameter base thickness - 40 - 45 mm. The length of the rectractable polyester tape is approx. 2.25 m. The tape shall be 48mm in width. The overall weight of the post will be approx. 8.5kg with cassette consisting of three receiving and one extension end for four way connectivity. The rate is including cost and conveyance of all materials, labour charges, sundries,lead,lift etc complete as directed by the Engineer in charge at all levels.

8

-

-

... More
19.6.2 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:150 mm dia R.C.C. pipe

52

-

-

... More
19.6.3 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:250 mm dia R.C. C. pipe

23

-

-

... More
od32870/2018_2019 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 200 mm dia RCC pipes.

5

-

-

... More
od32871/2018_2019 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.150 mm dia RCC pipes.

5

-

-

... More
od36496/2018_2019 : Supplying and Installation of vertical garden system including premium quality planting module ,drip irrigation system , mounting structure and necessary arrangements to fix the supporting structure etc. Planting module shall be of approved quality with suitable outdoor Plants .Mounting structure shall be with GI square tube frame work. Installation of all supporting structure and planting module, drip irrigation shall be done as per the direction of Engineer in charge .The rate shall include the cost and conveyance of all materials,planting module ,drip irrigation system , mounting structure,supporting structure, necessary arrangements to fix the supporting structure, labour charges, lead,lft etc complete as directed by the Engineer-in-Charge at all levels.

46.2

-

-

... More
DISMANTLING WORKS

-

-

-

... More
15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)

31.4

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

9.6

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

167.2

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

107.5

-

-

... More
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

36

-

-

... More
15.14.2 : Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area below 40 square centimeters

273

-

-

... More
15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet

85.2

-

-

... More
15.31 : Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.

408.4

-

-

... More
PAVEMENT WORK(MoRTH ITEMS)

-

-

-

... More
4.1.B.1 : Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 of MoRTH Specifications. Grading-V - For sub base cum drainage layer - Mix in Place Method

245.6

-

-

... More
4.12 : Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, complete as per MoRTH Specifications

245.6

-

-

... More
55.23 : Supplying and laying interlocking tile 80mm or nearest size thickness, minimum strength M30 including providing a layer of 6mm aggregate for 5cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc. complete as per MoRTH Specifications

1228

-

-

... More
8.1.B : Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 325 mm high in M 20 Grade PCC Using Concrete Batching and Mixing Plant on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409 of MoRTH Specifications

62.8

-

-

... More
3.3 : Excavation for road way in soil with Dozer including cutting and pushing the earth to site of embankment upto a distance of 100 metres (average lead 50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections , complete as per MoRTH Specifications

565.3

-

-

... More
3.6 : Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m, complete as per MoRTH Specifications

282.4

-

-

... More
8.8 : Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces , complete as per MoRTH Specifications

33.6

-

-

... More
SANITARY WORKS

-

-

-

... More
od37094/2018_2019 : Providing and fixing coloured vitreous china under counter wash basin of required size or equivalent of approved make including one CP brass pressmatic pillar cock 15 mm NB<br>including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling, 32<br>mm dia CP brass bottle trap,CP brass 15mm angle valve,complete including CI/MS brackets duly painted,<br>nuts, washers, etc. complete,cost and conveyance of all materials labour charges ,lead, lift necessary wall<br>cutting / chasing and making good the walls,floors,slab,testing and commissioning to the satisfaction of<br>Engineer in charge at all levels. (Model no: Queo Q757150310+Jaquar PRS-031+Jaquar OPP-<br>15053PM+Jaquar ALD-769L300+Jaquar ALD-709L130 or Models no: Grohe catalogue no:470LMR-WT+Kohler<br>Catalogue no: 20747IN-CP.+Queo Catalogue no:Q503191120+Q503195220+Q503191520 or equivalent).

8

-

-

... More
od37095/2018_2019 : Providing and fixing CP brass hand spray with lever control (health faucet) of make<br>1meter long flexibletube and wall hook,CP brass angle valve and all fittings including cutting and making<br>good the walls,floors,slab ,cost and conveyance of all materials, labour charges ,lead, lift testing and<br>commissioning to the satisfaction of Engineer in charge at all levels.(Model:Queo catalogue no<br>Q503192520+Q503191120 or Jaquar catalogue no:ALD 573+OPP-15053PM or equivalent)

8

-

-

... More
od37096/2018_2019 : Providing and fixing CP brass hand spray with lever control (health faucet) of make<br>1meter long flexibletube and wall hook,CP brass angle valve and all fittings including cutting and making<br>good the walls,floors,slab ,cost and conveyance of all materials, labour charges ,lead, lift testing and<br>commissioning to the satisfaction of Engineer in charge at all levels.(Model:Queo catalogue no<br>Q503192520+Q503191120 or Jaquar catalogue no:ALD 573+OPP-15053PM or equivalent)

15

-

-

... More
od37097/2018_2019 : Providing and fixing C.P. brass concealed stop cock (control valve) of standard design<br>and of approved make conforming to IS:8931 etc. including cost and conveyance of all materials, labour charges, lead,lift, necessary wall cutting / chasing and making good the walls,floor,slab etc complete, testing<br>and commissioning to the satisfaction of Engineer in charge at all levels.(Model-Jaquar catalogue no:ALD -<br>CHR-089+ FLR-CHR-5083NK or Queo catalogue no: Q503152720 or equivalent). 20mm diameter

2

-

-

... More
od37098/2018_2019 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame<br>with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour<br>charges, sundries etc complete as directed by the Engineer in charge at all levels.<br>75mm dia <br>

3

-

-

... More
od37099/2018_2019 : Providing and fixing CP brass robe hook etc complete testing and commissioning to the<br>satisfaction of Engineer at all levels. (Model-Jaquar catalogue no:AQN-7791 or Queo catalogue no:<br>Q363196120 or equivalent).The rate is including cost and conveyance of all materials, labour charges,<br>lead,lift ,cutting and making good the walls,floors,slab etc complete as directed by the Engineer in charge at<br>all levels

8

-

-

... More
od37100/2018_2019 : Providing and fixing frameless mirror complete, with all four edges machine<br>polished/bevelled and back side protected with safety film and 4 mm thick BWP grade Plywood backing and<br>fixed on walls with mirror screws(spacer). The rate is including cost and conveyance of all materials, labour<br>charges, lead,lift ,cutting and making good the walls,floors,slab etc complete as directed by the Engineer in<br>charge at all levels

5

-

-

... More
od37101/2018_2019 : Providing and fixing liquid soap dispenser of approved make including cost and<br>conveyance of all materials labour charges ,lead, lift, cutting and making good the walls, floors and slab<br>wherever required etc complete, testing and commissioning to the satisfaction of the Engineer in Charge at all levels .(Model:Jaquar catalogue no SDR-WHT-DJ0010F or Euronics ES 06-A or equivalent)

2

-

-

... More
od37102/2018_2019 : Providing and fixing of star white vitreous china urinal division plate of approved<br>quality and make with fittings/fastener including cutting and making good the walls,floors,slab ,cost and<br>conveyance of all material, labour charge, lead, lift, all taxes etc. complete as directed by the Engineer in<br>charge at all levels.(Model:Hindware catalogue no: F61001 or equivalent)

10

-

-

... More
od37103/2018_2019 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame<br>with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour<br>charges, sundries etc complete as directed by the Engineer in charge at all levels.<br>110mm dia<br>

3

-

-

... More
od37104/2018_2019 : Providing and fixing CP brass body bib cock etc. complete including cost and<br>conveyance of all materials labour charges ,lead, lift,including cutting and making good the<br>walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at all levels.<br>(Model:Jaquar catalogue no KUP-35037PM or Queo catalogue no:Q113113120 or equivalent) .

8

-

-

... More
od37105/2018_2019 : Providing & fixing star white vitreous china flat back urinal with CP brass flush valve<br>auto closing system with built in control cock and wall flange of approved size with all accessories to<br>provide satisfactory functioning including cost and conveyance of all materials, labour charges ,lead, lift<br>necessary wall cutting / chasing and making good the walls,floors,slab, as required for urinal flushing etc<br>complete, testing and commissioning to the satisfaction of Engineer in charge at all levels. (Model:Jaquar catalogue no: URS-WHT-13261+PRS-077or Hindware catalogue no:60002+Grohe catalogue no:36268000 or<br>equivalent).

10

-

-

... More
od37107/2018_2019 : Providing & fixing of star white vitreous China European wall hung pan with soft close<br>seat and lid with CP brass hinges and rubber buffers with concealed dual fushing cistern 3/9 litre water<br>storage with chrome finish wall plate actuator etc complete including all accessories, cost and conveyance<br>of all materials, labour charges,lead, lift ,necessary wall cutting / chasing and making good the<br>walls,floors,slab, testing and commissioning to the satisfaction of Engineer in charge at all levels. (Model no:<br>Queo catalogue no: Q357240110+Q507450100+Q507455120 or Model no: Jaquar Catalogue no: VGS-WHTPRICE 81951 +JCS-WHT- 2400 + JCP-CHR-152415 or equivalent).

8

-

-

... More
od37108/2018_2019 : Providing and fixing wall mounted tissue dispenser of approved make including cost<br>and conveyance of all materials labour charges ,lead, lift, ,cutting and making good the walls and floors<br>wherever required, testing and commissioning to the satisfaction of Engineer in Charge at all levels(Model<br>no:Jaquar-PTP-SAP-DT0106CS or Euronics catalogue no: EP 07AC or equivalent ).

2

-

-

... More
od37109/2018_2019 : Providing and fixing hand dryer of approved quality and make including cost and<br>conveyance of all materials labour charges ,lead, lift ,cutting and making good the walls and floors etc<br>complete as directed by the Engineer in charge at all levels.(Model-Jaquar catalogue HDR-WHT-M04A or<br>Euronics catalogue no: EH22 or equivalent).

2

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

10

-

-

... More
od37689/2018_2019 : Providing and fixing CP brass swan neck sink cock of approved make and quality<br>including cost and conveyance of all materials,labour charges,lead,taxes etc complete to the satisfaction of<br>Engineer in Charge at all levels.(Model no:Jaquar no: ARI-39347 or Kohler catalogue no:99482IN-4-CP or<br>equivalent ).

1

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

1

-

-

... More
od38083/2018_2019 : Providing and fixing sanitary fixtures for handicaped toilet including one wash basin of<br>size 65 x 35cm, one pair mounting brackets,one number pillar cock & all other related fittings like bottle trap<br>,angle cock,waste coupling, etc,one number EWC & Cistern complete with fittings & seat cover, one no.<br>hinged rail 76cm & 4nos. of grab rails 60cm etc designed for people with special needs comes with as per<br>manufactures specification including cutting and making good the walls and floors wherever required as per<br>drawing and as directed by Engineer in charge. (Model no: Hindware no:70002+Jaquar OPP-<br>15001PM+Jaquar ALD-709L130+Jaquar ALD-769L300+Jaquar OPP-15053 or Cera cruse set+Queo catalogue<br>no:Q113112120 + Q503191120 +Q503195220 +Q503191520 or equivalent)

1

-

-

... More
WATER SUPPLY

-

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

12

-

-

... More
18.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipes

12

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

84

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

84

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

3

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

6

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

1

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

6

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

4

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

4

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

4

-

-

... More
18.16.2 : Providing and fixing brass stop cock of approved quality :20 mm nominal bore

2

-

-

... More
18.33.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

2

-

-

... More
18.19.2.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):32 mm nominal boreHorizontal

1

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

4

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

2

-

-

... More
od37110/2018_2019 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <40mm dia>

2

-

-

... More
od37111/2018_2019 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <50mm dia><br>

6

-

-

... More
od37112/2018_2019 : Supply and erection of dual media filter of size 0.6m dia x 1.2 m HOS, (approx.) vertical type pressure vessel, mild steel internally and externally epoxy coated, 6mm shell thickness, 6mm dish thickness, flanged top and bottom, operating pressure of 3.5 Kg/cm2, complete with CI valves and graded pebble and sand as media, frontal piping, pressure gauges, strainers, supporting structure, back wash arrangement, etc and all other accessories. Flow rate - 5 m3/hr<br>

1

-

-

... More
od37113/2018_2019 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge <br>50mm 'Y' type strainer<br>

4

-

-

... More
od37114/2018_2019 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge <br>40mm 'Y' type strainer<br>

1

-

-

... More
od37115/2018_2019 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge.<br>65mm Dia<br>

2

-

-

... More
od37116/2018_2019 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mm

2

-

-

... More
od37117/2018_2019 : Supplying, laying, jointing, testing and commissioning to the satisfaction of Engineer in charge of hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps including cutting and making good the walls,testing the lines rectifying any leakages or defects,etc. complete for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for concealed work as directed by the Engineer- in-Charge. MAKE: Astral/Ajay/Ashirvad or equivalent<br>50mm dia (6kg/cm2)

18

-

-

... More
od37118/2018_2019 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 300 mm dia RCC pipes.

104

-

-

... More
od37119/2018_2019 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge<br>75mm OD (6 kg/cm2)<br>

6

-

-

... More
od37120/2018_2019 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge<br>75mm OD (4 kg/cm2)<br>

18

-

-

... More
od37121/2018_2019 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge<br>110mm OD(6 kg/cm2)<br>

210

-

-

... More
od37122/2018_2019 : Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.

3

-

-

... More
od37123/2018_2019 : Providing and fixing 110mm dia PVC vent cowl to pipe already fixed as directed by Engineer-in-charge at all levels. 110mm dia

3

-

-

... More
od37124/2018_2019 : Providing and fixing PVC vent cowl to pipe already fixed as directed by Engineer-in-Charge at all levels.75 mm dia

3

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

-

-

... More
2.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia

10

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

104

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

42

-

-

... More
od37125/2018_2019 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 200 mm dia 6 Kgf/cm2

6

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

30

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

12

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

150

-

-

... More
od37126/2018_2019 : Supplying, laying, jointing, testing and commissioning to the satisfaction of Engineer in charge of hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps including cutting and making good the walls,testing the lines rectifying any leakages or defects,etc. complete for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for concealed work as directed by the Engineer- in-Charge. MAKE: Astral/Ajay/Ashirvad or equivalent<br>110mm dia

30

-

-

... More
od37128/2018_2019 : Supplying and installing activated carbon filter of size 5 m3/hr,operating pressure of 3.5<br>Kg/cm2 with internally and externally epoxy coated, raw water distributor, filter water collecting system, pressure gauges at inlet and outlet, strainers, supporting structure, back wash arrangement, set of inlet and outlet valves, V-notch Board etc and all other accessories .The rate shall include cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.

1

-

-

... More
od37129/2018_2019 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency Capacity : 5 m3/hrHead : 35m<br>

2

-

-

... More
od37130/2018_2019 : Chemical dosing system<br>Supplying and fixing of electronic dosing pump with all wetted parts in PP construction suitable for pumping HOCl solution including cost of valves, suction and delivery lines using heavy duty PVC tubes, FRP tank of 80 litres capacity, FRP motor cover etc. and complete with all accessories.<br>Capacity : 6 lph @ 3.5 kg/cm2

1

-

-

... More
od37131/2018_2019 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels<br>Capacity: 6m3/hr<br>Head: 27 m

4

-

-

... More
od37132/2018_2019 : Providing and fixing enclosed type water meter (bulk type) 65mm dia conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.

1

-

-

... More
od37133/2018_2019 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge<br>200mm dia

1

-

-

... More
od37134/2018_2019 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge<br>150mm dia

2

-

-

... More
od37135/2018_2019 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge<br>100mm dia

3

-

-

... More
od37136/2018_2019 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge<br>80mm dia

2

-

-

... More
od37137/2018_2019 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge<br>65mm dia

2

-

-

... More
od37138/2018_2019 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge<br>200mm dia

1

-

-

... More
od37139/2018_2019 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge<br>150mm dia

2

-

-

... More
od37140/2018_2019 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge<br>100mm dia

2

-

-

... More
od37141/2018_2019 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge<br>80mm dia

5

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

-

... More
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

1

-

-

... More
od37142/2018_2019 : Providing and fixing C.I. basket type dirt box strainer for bulk type water meter with nuts, bolts, all accessories etc. complete conforming to IS : 2373 : including cost and conveyance of all materials, labour etc. complete and as directed by Engineer in charge<br>65mm dia

1

-

-

... More
od37143/2018_2019 : Providing and fixing C.I. basket type dirt box strainer for bulk type water meter with nuts, bolts, all accessories etc. complete conforming to IS : 2373 : including cost and conveyance of all materials, labour etc. complete and as directed by Engineer in charge<br>80mm dia

1

-

-

... More
od37144/2018_2019 : Supply and installation of water level indicator with electronic integrated circuit and necessary accessories etc complete as directed by the Engineer in charge at all levels

6

-

-

... More
od37145/2018_2019 : Supplying,installing, testing and commisioning of electronic integrated circuits and wireless water level controller including necessary cabling and transformers with all accessories etc complete as directed by Engineer in charge for water supply level control in water tanks

3

-

-

... More
od37146/2018_2019 : Providing and fixing enclosed type water meter (bulk type)80mm dia conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.

1

-

-

... More
od37147/2018_2019 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80 mm dia

7

-

-

... More
od37660/2018_2019 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having<br>thermal stability for hot & cold water supply, including all CPVC plain & brass<br>threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This<br>includes jointing of pipes & fittings with one step CPVC solvent cement and<br>testing of joints complete as per direction of Engineer in Charge.<br>Internal work - Exposed on wall 65mm nominal dia

54

-

-

... More
od37661/2018_2019 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold<br>water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m<br>spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of<br>cutting chases and making good the same including testing of joints complete as per direction of<br>Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.40 mm<br>nominal outer dia pipes

6

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

60

-

-

... More
od37685/2018_2019 : Supplying ,fixing, testing and commissioning of portable drainage pump with 12mm<br>solid handling, with stainless steel construction, stainless steel impeller complete with motor , with carrying<br>handle and all accessories and working with 415V, 3ph and 50 Hz frequencyCapacity:10m3/hour,Head-15m

2

-

-

... More
od37686/2018_2019 : Providing and fixing CI Y type strainer 65mm dia rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,<br>labour etc. complete and as directed by Engineer-in-Charge<br>Other Engineering Organisations<br>P R I C E<br>1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,<br>labour etc. complete and as directed by Engineer-in-Charge<br>

2

-

-

... More
50.18.8.1.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2

6

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

48

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

96

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

12

-

-

... More
HT EQUIPMENTS, 11 KV DP STRUCTURE

-

-

-

... More
(SH : HT EQUIPMENTS AND CABLING)- 11KV DP STRUCTURE Supply, Erection, Testing and Commissioning of 11 KV DP structure using 200x100 mm ISMB for poles and cross channel of ISMC 100x50mm and supporting structure for 11 kV components with MS angle bracings between consumer and supplier structure,cross arms,11 kV pin,disc and stay insulators, supports, jumpering / interconnecting conductors with '0'SWG Cu, anticlimbing arrangement using barbed wire,earthing etc. on a suitable concrete foundation complete including the cost of foundation The DP structure shall consists of the following. (All the MS items shall be finished using zinc chromate primer & 2 coats of synthetic enamel paint) (Note:The work shallbe as per KSEI & KSEB standards) 11 kV, 400A , single brake,TP, gang operated AB switch with operating handle & locking mechanism - 1 No 11 kV Lighting Arrestor -1 set of 3 Nos 11 kV Drop out fuses-1 sets of 3 Nos 11kV outdoor type CT/PT unit with, class 0.2s, 15VA CT & 11kV/110V class 0.2s, 100VA PT - 1set The DP structure shall be with all necessary accessories for connecting 11kV cable .

1

-

-

... More
"METERING PANEL Supply, Erection, Testing and Commissioning of TOD meter KIOSK with TOD meter and test terminal block, control fuses,armoured copper cable between CTPT unit and TOD meter.The KIOSK shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54, weather proof,undergone seven tank process,powder coated finish ,earthing,entire civil work including suitable foundation and all mounting accessories as required complete as per the rquirement of K.S.E.B "

1

-

-

... More
Supplying and filling the proposed yard with 40 mm size blue jelly upto 150 mm thick including cost and conveyance of all materials, labour charges etc. complete.

4

-

-

... More
11kV Load Break Switch Unit Supply, installation, testing and commissioning of LBS panel, totally enclosed, free standing, floor mounting, dust & vermin proof, outdoor cubicle type, IP42, made of 14SWG sheet steel powder coated with necessary cable alley & busbar chamber. The panel shall be with 630A aluminium PVC sleeved busbar & support insulators, space heater with thermostat, cubicle illumination lamp, MCBs for AC/DC Control etc, seal off bushings, control wiring etc. The panel also consists of 11kV, 21 kA, 630A Load Break Switch with earth switch - 1 no, HT HRC fuse 50A - 3 nos, Seal off Bushing - 1 set, Shunt trip coil, 230V AC - 1 set, Space heater with thermostat - 1 set, Suitably rated Aluminium busbars and support insulators, ON-OFF indication- 1 set, The rate is inclusive of transportation, insurance, lift, lead and all associated works. The panel shall be with bottom entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram.

1

-

-

... More
250 KVA DG Set Supply, installation, testing and commissioning of 1 No. 250 kVA, 415V, 3 phase, 1500 R.P.M, 0.8 PF(Continuous duty), water cooled, radiator type, four stroke, electric start prime duty, floor mounted Diesel Generator set with acoustic enclosure (outdoor duty) and all accessories including supply and installation of standard control panel with metering and protections,controls and interlocks, suitable MCCB for Overcurrrent & Earth Fault Protection, CTs and transducers for all metering and protection, Antivibration mountings, exhaust silencer and exhaust pipe along with Acoustic Enclosure(sound pressure level as per ISO standards), electric starter, batteries & battery charger, fuel tank suitable for 8 hrs of continuous operation with level indicator, radiator, necessary control wiring with control cables, first fill of lubricating oil, and Diesel for testing and commissioning, earthing as per standards and all accessories as required. The rate shall be inclusive of all lift,lead, first fill of oil etc.(Refer particular specification.) The work should be as per Electrical Inspectorate/ Pollution control board standards.

1

-

-

... More
250KVA 11KV/0.433KV UNITISED SUBSTATION - Design, fabrication,Supply, installation, testing and commissioning of indoor type Unitized Substation enclosure consisting of 11 KV, 630A, 26.3kA for 3 sec VCB with fully encapsulated vacuum interrupter panel , 250 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP23 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works etc. complete as per single line diagram & technical specification. HT Compartment - 11KV, 26.3kA for 3 sec, 630A motorised VCB 630 Amp continously rated Cu busbar, Self powered microprocessor based three over current and one earth fault relay with protection CT's - 1 set, Master trip relay and all accessories complete as required., Battery and battery charger - 1 set, Provision for padlocking for open, close, earth and test position, Transformer Compartment - 250 kVA, 11kV/433V 3 Ph, 50Hz, dry type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: +5% to -5% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 80/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay in HT/LT panel as per SLD LV Chamber - Suitable for termination of LT cable.

1

-

-

... More
LT PANEL BOARDS, UPS AND ACCESSORIES

-

-

-

... More
Supply , Installation, Testing and Commissioning of 3 kVA, single phase input, single Phase output, true on-line UPS system with 15 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . Refer technical specification and drawing for details. Fully digital controlled based on DSP, Power factor corrected from end 0.9, Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch System efficiency 90%, Auto temperature compensation

1

-

-

... More
MSB PANEL - MSB: SITC of LT Switch Board (MSB), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI/ERDA certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction. Incomer - Incomer 1 -400A, FP, 50kA, MCCB with Microprocessor based release with OL & SC protection - 1 No, Instruments - 4A, C curve SP MCB - 3 nos, RYB indication lamp, LED type - 1 set, (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch - 1 no, (0-400)A ammeter Acc. class 1 with 90 deg defl. scale - 3 Nos. 400/5A 15VA class 1 resin cast CT - 1 set, 400/5A 15VA class 1 resin cast CT - For IPFC relay, ON/OFF/TRIP indication lamp, LED type - 1 set, 'Multifunction meter - 1 No, Busbar - 400A TPN busbar chamber with Aluminium busbar. Out goings - 320 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) -1 no, 160 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) -3 nos, The Provision for of Energymeter, cutout fuses and breaker for Commercial Loads as per SLD - 5 nos. The panel shall be with bottom entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram.

1

-

-

... More
EMERGENCY PANEL - Emergency Panel: SITC of LT Switch Board (MSB), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI/ERDA certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction. Incomers - Incomer 1 -320A, FP, 50kA, MCCB with Microprocessor based release with OL & SC protection - 1 No. Incomer 2 -400A, FP, 50kA, MCCB with Microprocessor based release with OL & SC protection - 1 No AMF relay with electrical and mechanical interlocking provision with Incomers -1 No 320 A Heavy duty Contactor-1 no 400 A Heavy duty Contactor -1 no Instruments - 4A, C curve SP MCB - 2 sets., RYB indication lamp, LED type - 2 set, (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch - 2 nos, (0-400)A ammeter Acc. class 1 with 90 deg defl. scale - 3 Nos., (0-320)A ammeter Acc. class 1 with 90 deg defl. scale - 3 Nos., 400/5A 15VA class 1 resin cast CT - 1 set, 320/5A 15VA class 1 resin cast CT - 1 set, ON/OFF/TRIP indication lamp, LED type - 2 Sets. Busbar - 400A TPN busbar chamber with Aluminium busbar. Out goings - 200 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) -1 no, 160 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) - 1 nos, 125 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) - 1 nos, 63 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) - 1 nos, 40 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) - 2 nos, 320 A FP SDU -1 nos, The panel shall be with bottom entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram.

1

-

-

... More
70 KVAR APFC PANEL Supply, Installation, Testing & Commissioning of Capacitor Panel Board , cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc., including provision for capacitor mounted inside the panel with adequate number of louvers and powder coated with approved shade and having following specific components all inter connections and following components as per drawing and technical specifications. The Panel shall be of Form 3b Construction. Incomer 160 A, FP MCCB with adjustable thermal magnetic release with OL & SC protection - 1 no. Instruments - 4A, C curve SP MCB - 3 nos., RYB indication lamp, LED type - 1 set, (0-500)V voltmeter, Acc. class 1 with 90 deg defl. Scale with selector switch - 1 no.,(0-160)A ammeter Acc. class 1 with90 deg defl. Scale with selector switch - 1 no., 160/5A 15VA class 1 resin cast CT - 1 set, Microprocessor based intelligent, 6 step IPFC relay with PF display - 1 No., Auto / manual selector switch - 1 no., ON-OFF-TRIP indication lamp - 1 set. Busbar - 160A TPN busbar chamber with Aluminium busbar. Outgoing - 63A, 25kA, TP MCCB with adjustable thermal magnetic release with OL & SC protection - 3 nos., 32A, 25kA, TP MCCB with adjustable thermal magnetic release with OL & SC protection - 3 nos., 30 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type)- 1 Nos., 20 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type)-1 Nos., 10 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 1 No., 5 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 2 No., 30 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 1 Nos, 20 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 1 Nos, 10 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor -1 No, 5 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 2 No, Control wiring required for no load compensation capacitor, The panel shall be with bottom entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram.

1

-

-

... More
HVAC PANEL Supply , Installation, Testing & Commissioning of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.TThe panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction. Incomer - 200A FP MCCB with adjustable thermal magnetic release with OL & SC protection-1 No, Busbar- 200A TPN busbar chamber with Aluminium busbar , Meters - 4A, C curve SP MCB - 3 Nos., RYB indication lamp, LED type - 1 set, (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch - 1 no, (0-200) A ammeter Acc. class 1 with 90 deg defl. Scale with Ammeter Selector Switch - 1 no, 200/5A 10VA class 1 resin cast CT - 1 set, ON OFF TRIP indication lamp - 1 set, Outgoings - 40 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) -2 nos, 100 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) -3 nos, 63 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) - 1 nos, 3 ph energymeter of accuracy class 1 with RS485 communication port -2 nos 100/5 A ,3 ph energymeter of accuracy class 1 with RS485 communication port -2 nos 100/5 A, 15 VA, class 1,resin cast CT -2 nos, The panel shall be with bottom entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram.

1

-

-

... More
Pump panel - 1 Supply, Installation, Testing & Commissioning of LT Panel cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 42, free standing, indoor, floor mounting, dust and vermin proof, compartmentalised, suitable for operation on 3 phase, 415 V, 50Hz AC system with busbars extendable on both sides, including internal wiring with suitable size wires/cable, interconnection, duly powder coated etc., including supply & installation of following switchgears, metering instruments and accessories in the LT Panel and as per specifications. The Panel shall be of Form 4b Construction. Incomer - 40 A FP MCCB with adjustable thermal magnetic release with OL & SC protection- 1 no. , BUSBARS - 40 Amp TPN busbars of high conductivity electrolytic quality aluminium conductor INSTRUMENTS - 4A, C curve SP MCB - 3 Nos., RYB phase indicating lamps, LED type -1 Set, Voltmeter (0 to 500 V) for 3 phase, 4 wire operation with selector switch -1 no, Ammeter (0 to 40A) with selector switch -1 no, 40/5A 10VA class 1 resin cast CT - 1 set, ON OFF TRIP indication lamp - 1 set Outgoing - 32 A TPN SDFU with suitable HRC fuses - 8 nos, On/Off indication lamp, LED type for out goings - 7 set., 3 phase DOL starter with on/off push button,thermal overload relay, single phasing preventer and auxillary &power contactors for 3 HP motor - 4 nos. , 3 phase DOL starter with on/off push button,thermal overload relay, single phasing preventer and auxillary &power contactors for 2 HP motor - 3 nos., Space provision for fixing 3 phase DOL /star-delta starter with on/off push button, thermal overload relay, single phasing preventer and auxillary & power contactors & ON/OFF indication lamps,capacitors in spare outlets , The panel shall be with bottom entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram.

1

-

-

... More
CABLES AND CABLING, HT CABLING

-

-

-

... More
Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date. 3C X 300sq.mm.

40

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm

2

-

-

... More
Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required Above 120 sq. mm and upto 400 sq. mm

8

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm

28

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm

2

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 3C X300 sq.mm.

1

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 3C X300 sq.mm.

1

-

-

... More
Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 3C X300sq.mm.

1

-

-

... More
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

-

-

-

... More
3.5C 240 Sq.mm Al

16

-

-

... More
3.5C 185 Sq.mm Al

210

-

-

... More
3.5C 120 Sq.mm Al

61

-

-

... More
3.5C 70 Sq.mm Al

12

-

-

... More
3.5C 35 Sq.mm Al

214

-

-

... More
4C 16 Sq.mm Al

68.8

-

-

... More
4C 10 Sq.mm Al

72

-

-

... More
4C 6 Sq.mm Al

82.8

-

-

... More
4C 4 Sq.mm Al

108.6

-

-

... More
3C 4 Sq mm Al

81

-

-

... More
2C 4sqmm Al

236.2

-

-

... More
2C 6sqmm Al

288.4

-

-

... More
4C 16 Sq.mm Cu

23

-

-

... More
4C 10 Sq.mm Cu

23

-

-

... More
2C 10 Sq.mm Cu

23

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3.5C 240 Sq.mm Al

2

-

-

... More
3.5C 185 Sq.mm Al

18

-

-

... More
3.5C 120 Sq.mm Al

4

-

-

... More
3.5C 70 Sq.mm Al

2

-

-

... More
3.5C 35 Sq.mm Al

14

-

-

... More
4C 16 Sq.mm Al

6

-

-

... More
4C 10 Sq.mm Al

4

-

-

... More
4C 6 Sq.mm Al

4

-

-

... More
4C 4 Sq.mm Al

12

-

-

... More
3C 4 Sq mm Al

12

-

-

... More
2C 4 Sq.mm Al

20

-

-

... More
2C 6 Sq.mm Al

12

-

-

... More
4C 16 Sq.mm Cu

4

-

-

... More
4C 10 Sq.mm Cu

4

-

-

... More
2C 10 Sq.mm Cu

23

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall or surface as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

283.2

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

3

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

21

-

-

... More
Laying of one number PVC insulated and PVC sheathed armoured power cable of 1.1kV grade fo the following sizes in ground including excavation ,sand cushioning , providing protective covering and refilling the trench etc. as required Upto 35 sq. mm

30

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm

5

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Upto 35 sq. mm

257

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

3

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

53

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

576.6

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

3

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

145

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

10

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.

-

-

-

... More
Upto 35 sq. mm

74

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

1

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

52

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

6

-

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required

-

-

-

... More
50 mm

150

-

-

... More
100 mm

20

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 mm dia

30

-

-

... More
Fabrication, supply and installation of following size of ladder type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and painting etc as required

-

-

-

... More
150 MM WIDTH X 75 MM DEPTH X 2 MM THICK

87

-

-

... More
300 MM WIDTH X 75 MM DEPTH X 2 MM THICK

34

-

-

... More
450 MM WIDTH X 75 MM DEPTH X 2 MM THICK

10

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

80

-

-

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

20

-

-

... More
Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required

500

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

10

-

-

... More
Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke & Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.

1

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Total distance from switch board to first point will not exceed 5 metres.

143

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLSPVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(With Medium range Switches-Make: MK Blenz or equivalent approved make)Total distance from point to point point will not exceed 5 metres, incase if the length exceeds 5 metres.

16

-

-

... More
Group controlled wiring for light point (from point to point) with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit and earthing the point with 1.5 sq.mm. FRLSH PVC insulated copper conductor single core cable etc as required.This item does not include the cost of MCB, 6/16A switches.Total distance from point to point will not exceed 5 metres.

60

-

-

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

747

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

760

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

379

-

-

... More
Supplying and fixing following modular switch/ socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete.

-

-

-

... More
Bell push

1

-

-

... More
15/16 amp switch

8

-

-

... More
6 pin 15/16 amp socket outlet

8

-

-

... More
5/6 amp switch

12

-

-

... More
3 pin 5/6 amp socket outlet

12

-

-

... More
Telephone Socket

4

-

-

... More
Supplying and fixing stepped type electronic fan regulator with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete.

2

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

1

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

12

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

5

-

-

... More
Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

3

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

100

-

-

... More
25 mm

100

-

-

... More
32 mm

50

-

-

... More
Supply and fixing outdoor type(IP 65) cable end termination box with metric knock outs for cable entry suitable for terminating 2.5 sq.mm cable including all the necessary accessories as required complete with suitable mounting arrangement.(Hensel- or equivalent approved make).MS item for the mounting cable termination box shall be measured separately.

7

-

-

... More
MCBs AND MCB DISTRIBUTION BOARDS Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 125/160 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB’s/ MCCB) with suitable cable entry box as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 Way TP

1

-

-

... More
6 Way LB

1

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way Double door

2

-

-

... More
8 way Double door

1

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6way (4 + 18), Double door

3

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way (4 + 18), Double door

6

-

-

... More
8way (4 + 24), Double door

1

-

-

... More
12 way, Double door

1

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
160 Amp,16KA,FPMCCB

1

-

-

... More
125Amp,16KA,FPMCCB

1

-

-

... More
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required.

-

-

-

... More
2 pole 25 amps. (230 Volts),30mA sensitivity.

7

-

-

... More
4 pole 25 amps. (415 Volts),30mA sensitivity.

3

-

-

... More
4 pole 40 amps. (415 Volts),30mA sensitivity.

4

-

-

... More
Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required.

-

-

-

... More
6A to 32A, SP, C-CURVE

92

-

-

... More
6 A to 32 A TP MCB, C-CURVE

10

-

-

... More
40 A to 63A TP MCB, C-CURVE

6

-

-

... More
6A to 32A, SP, D-CURVE

42

-

-

... More
Supply, Installation, Testing & Commissioning of 32A DP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

3

-

-

... More
Supply, Installation, Testing & Commissioning of 32A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

6

-

-

... More
Supply, Installation, Testing & Commissioning of 40A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 63A FP isolator in weather proof enclosure on surface including all the mounting accessories, internal wiring etc as required complete.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 100A FP isolator in weather proof enclosure on surface including all the mounting accessories, internal wiring etc as required complete.

2

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

20

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

1

-

-

... More
Supply, installation & commissioning of programmable recess/surface mounted PIR occupancy sensor having the following range and with in built day light sensor with passive photocell. The sensor shall have adjustable off delay timer, sensitivity level adjustment etc prewired complete with all required accessories. 6m dia range at 2.5m mounting height. Make: Honeywell K5017 or equivalent approved make

5

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
Supply of indoor industrial surface mounted LED tube and batten along with driver , surge protector,system wattage of 20+/-2 Watts,lumen output of lamp greater than 1400lumen, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all necessary accessories as required complete.Make:- Cat No Wipro WIO 921208+ 1 Nos. of 18W LED Tube Light or Crompton Greaves IGP131LT8-16+LT8-16 or equivalent model from approved make

19

-

-

... More
Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 20+/-2 Watts,lumen output of lamp greater than 1400, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Philips BN021C LED20S PSU NW GR or Wipro LL20-221-XXX-65NE1 or Crompton Greaves DMLN1LT16+LT16 or equivalent model from approved make

53

-

-

... More
Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 10+/-2 Watts,lumen output of lamp greater than 800, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Philips BN021C LED20S PSU NW GR or Wipro LL20-111-XXX-65NE or Crompton Greaves DMLN1LT16+LT8 or equivalent model from approved make

9

-

-

... More
Supply of LED recess mounted down light made of die cast aluminium, along with driver,system wattage of 15+/-3 Watts, CCT- 4000K (warm white) with lumen output of lamp greater than 1200 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 90 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: Philips DN 394B LED16S-3000 PSU WH or Wipro LD90-191-XXX-40-XX or Crompton Greaves LCDN-15-CDL/TL/WW or equivalent model from approved make

65

-

-

... More
Supply of LED surface mounted down light made of die cast aluminium with corrosion resistance p[owder coating, along with driver,system wattage of 24+/-3 Watts,IP 65, CCT- 3000K (warm white) with lumen output of lamp greater than 2000 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 90 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: LT SO2430100 or equivalent model from approved make

8

-

-

... More
Supply of LED coloumn washer made of die cast aluminium with corrosion resistance powder coating, along with driver,system wattage of 12 +/-3 Watts,IP 65, CCT- 3000K (warm white) with lumen output of lamp greater than 1000 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 90 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO - LW33-101-025-30-XX or equivalent one)

2

-

-

... More
Supply of LED light suitable for outdoor lighting made of die cast aluminium, along with driver,system wattage of 25 +/-3 Watts, IP 66, with pf 0.9lumen output of lamp greater than 2500 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt , with provision for,mounting or extension and including all necessary accessories as required complete.Make:- Cat No: CG- BRP320 1x24LED-HP/CW PSU GR or Wipro LR02-291-XXX-57-XX or equivalent model from approved make )

6

-

-

... More
Supply of LED path finder light made of die cast aluminium alloy with non corrosive SS fasteners, along with driver,system wattage of 9+/-3 Watts,lumen output of lamp greater than 800 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, with CCT -3000 K, and including all necessary accessories as required complete.Make:- Cat No: Klite Veto or equivalent model from approved make

20

-

-

... More
Supply of following sizes of 1200 mm sweep. 5 star rated ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, 30 cm down rod and without speed regulator suitable for 240V 50 HZ, AC supply confirms to IS 374/1979 as required complete. (Make crompton-High Speedor equivalent approved make).

2

-

-

... More
Supply of 400 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.(Make crompton-High Flo or equivalent approved make).

2

-

-

... More
Supply of 450 mm sweep,900 rpm heavy duty exhaust fan in metal body with louvers working on 230 V AC supply complete with all accessories as required. (Crompton EXHD 450 -6-1 or equivalant approved make)

4

-

-

... More
Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton Brisk Air or equivalant approved make)

5

-

-

... More
ITC LIGHT FITTINGS AND FANS

-

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

101

-

-

... More
Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor as required.

73

-

-

... More
Installation, testing and commissioning of High bay/LED/ T5 FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required.

8

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

2

-

-

... More
Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc as required.

9

-

-

... More
Installation, testing and commissioning of Wall fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

2

-

-

... More
Numbering of ceiling fan / exhaust fan/ fluorescent fitting as required.

195

-

-

... More
EXTERNAL LIGHTING AND COVE LIGHTING, EXTERNAL LIGHTING

-

-

-

... More
Supply, installation testing and commissioning of of LED bollards with a dia of 120 mm and 500 mm height having symmetrical illumination on ground surfaces with uniform luminance. LED lamp upto 12W can be fixed in the fixture. The body shall be made of extruded aluminium alloy with die-cast aluminium components and non corrosive SS fastners,cast iron/aluminium mounting plate for bolting into a foundation. Glare free reflector system encased in clear UV protected polycarbonate diffusers for rotationally symmetrical distribution of light. Luminaries provided with LED driver ,MCB control and suitable for operation on 240V, 50Hz single phase ac supply. IP 44 compliant Bollards are mounted with E27 holders providing IP65 class protection & Terminal Connectors for Loop-in Loop out System.( Klite cuba Bollard or equivalent approved make)

6

-

-

... More
Supply, installation, testing and commissioning of street light pole of 4.2 meter height suitable for mounting 1 number of LED street Light fixtures. The pole shall be of hot dip galvanised 3 mm thick MS sheet, primered and polyurethane painted The LED Street Lighting luminaire shall be of IP54 protected, pressure die cast aluminium housing body with optimal heat sink, inbuilt Surge Protection device, with system wattage less than 25(+/-5)W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 2500 and system efficiency greater than or equal to 90%.The Light fitting shall be with all required accessories suitable for mounting in on the pole arm. The luminaire should meet all the technical specifications as mentioned. The pole with bracket,built-in control box of same material with service door coated with epoxy zinc phosphate primer and finished with polyurethane based paint . The control box is prewired with DP MCB, FP connector for easy loop-in loop-out suitable for 3phase 4 wire AC supply (LT cables).The pole shall have provision for connecting the earth wire.(Make KLITE AVIRA or equivalent approved make , Pole:- KLITE KP-4279 or BAJAJ or equuivalent approved make).

8

-

-

... More
COVE LIGHTING - Supply, installation,testing and commissioning of 24V 9.6W 400mA LED strip light suitable for cove lighting with color temperature of 3000K ,IP 20 and CRI 90-95, rated life of L70 @ 50,000 hours with channel casing and acrylic cover complete with all necessary accessories like driver and all mounting arrangements like profile with PMMA Diffuser to terminate to a point wiring out. (Make : YYZ lighting LFX-I-09.60-CT XX or any other equivalent approved make)

200

-

-

... More
Supply, installation,testing and commissioning of 24V 9.6W 400mA LED strip light suitable for cove lighting with color temperature of 3000K ,IP 67 and CRI 90-95, rated life of L70 @ 50,000 hours with channel casing and acrylic cover complete with all necessary accessories like driver and all mounting arrangements like profile with PMMA Diffuser to terminate to a point wiring out. (Make : YYZ lighting LFX-I-09.60-CT XX or any other equivalent approved make)

60

-

-

... More
LIGHT MANAGEMENT SYSTEM

-

-

-

... More
Supply and installation of of LED recess mounted down light made of die cast aluminium, along with 1-10 V analog dimmable driver,system wattage of 18+/-3 Watts,lumen output of lamp greater than 2000 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, CCT - 4000K system efficacy greater than 90 lumen/watt and including all necessary accessories including control wiring as required complete and fitting must be suitable for 1-10 V analog dimming.Make:- Cat No: Philips RS271B LED20S-4000 IA WB WH or Wipro LD56-251-060-40-AN

50

-

-

... More
Supply, erection, testing and commissioning of 4- channel dimming module with high inrush relays rated at 16 A per channel. The outputs should be able to control loads including 0/1-10 V DSI, DALI broadcast and PWM . The Ballast controller should have an intutive LED segment display and push buttons for monitoring, manual and control purposes The Scope of Work also includes necessary control wiring, supply and installation of IR Remote control and modular panel (4 Button Keypad + Raise + Lower +ON/OFF) along with frame and power supply unit.

2

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

2

-

-

... More
Supply & providing ISI plate earthing as per IS 3043 with 1200x1200x12.5mm GI / CI earth plate with 20mm dia B class GI pipe for watering, 50x6mm GI strip welded to the plate, GI funnel with weld mesh, fixing GI strip of size 50x6mm with min. length of 20cm clamped with 50x6mm GI flat using 12x10mm GI bolt & nut at top of the GI pipe as test joint, filling around the GI pipe at a radius of 15cm with a homogeneous mixture of charcoal, & river sand upto a height of 2.5 meter from the bottom, filling the rest of the portion with excavated soil including watering & ramming providing brick work (20cm) masonary at top in 1:6 cement mortar, plastering the inside & top of the manhole with 12mm thick 1:6 cement mortar and providing gully trap with 450x450x10mm CI covering at the top.

6

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

5

-

-

... More
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.

-

-

-

... More
32mm X 6mm GI

40

-

-

... More
25mm X 6mm GI

913.9

-

-

... More
25mm X 3mm Cu

20

-

-

... More
3.15mm Cu (10 SWG)

832.3

-

-

... More
8 swg gi wire

206.2

-

-

... More
6 SWG gi wire

60

-

-

... More
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

-

-

-

... More
32mm X 6mm GI

117

-

-

... More
25mm X 6mm GI

100

-

-

... More
25mm X 3mm Cu

30

-

-

... More
3.15mm Cu (10 SWG)

40

-

-

... More
8swg gi wire

362.9

-

-

... More
Supply and providing ISI marked electrical 1.1 kV grade anti-skid rubber mat as per IS:15652.forthe following sizes.

-

-

-

... More
2mx1mx2mm thick

3

-

-

... More
2mx1mx2.5mm thick

1

-

-

... More
Supply and fixing of First aid box

1

-

-

... More
Supplying of Rubber hand gloves suitable for 11 KV.

1

-

-

... More
Supply and fixing anodised aluminum glass framed shock treatment chart.

1

-

-

... More
Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

1

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece,roof conductor holder, base and other accessories required as per IEC 62305-3

270

-

-

... More
Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece , roof holders , holding base and other accessories required as per IEC 62305-3

120

-

-

... More
Providing and fixing of test joint suitable for hot dipped galvanized steel tape 30 mm x 3mm and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade . Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm.

10

-

-

... More
Providing and laying hot dipped galvanized steel tape 30 mm X3 mm from earth electrode directly in ground as required. Flat conductor shall be of hot dipped and cross sectional area of 90 sqmm and cross connectors must be provided at crossings. Zinc coating: 500g/m square and should be tested and used for lightning protection earth system and equipotential bonding.

195

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

10

-

-

... More
MECHANICAL WORKS

-

-

-

... More
VRF System Supply, Installation ,testing and commissioining of 34HP minimum capacities of Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with multiple compressors, with variable speed inverter driven compressor as per specifications complete with suitable capacity drive motors, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, structural supports, high-low pressure cut out, with ODU vibration isolators, suitable for 3 phase, 415 V, 50Hz supply, starter panel, power wiring from starter panel,central controller, along with associated accessories for controlling entire VRF system along with power consumption monitoring of each individual indoor units with PDI, wattmeter as required along with suitable interconnecting control cabling between IDUs,ODUs and central controlller ,Power wiring with necessary supports , necessary power/control panel, power/control cabling between isolator and single/multiple outdoor units along with associated accessories, structural supports /RCC/ cement concrete foundation etc. complete in all respects as per the technical specifications. (single feeder power source will be provided for 34HP outdoor units by client )

1

-

-

... More
Supply, Installation ,testing and commissioining of 32 HP minimum capacities of Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with multiple compressors, with variable speed inverter driven compressor as per specifications complete with suitable capacity drive motors, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, structural supports, high-low pressure cut out, with ODU vibration isolators, suitable for 3 phase, 415 V, 50Hz supply, starter panel, power wiring from starter panel,central controller, along with associated accessories for controlling entire VRF system along with power consumption monitoring of each individual indoor units with PDI, wattmeter as required along with suitable interconnecting control cabling between IDUs,ODUs and central controlller ,Power wiring with necessary supports , necessary power/control panel, power/control cabling between isolator and single/multiple outdoor units along with associated accessories, structural supports /RCC/ cement concrete foundation etc. complete in all respects as per the technical specifications. (single feeder power source will be provided for 28HP outdoor units by client )

1

-

-

... More
Supply,Installation ,testing & commissioning of 2.0 TR (minimum capacity) Hi wall Split air conditioning unit complete with suitable capacity drive motor, control cabling(indoor to outdoor),thermostat wiring,drain piping,, out door vibration isolators, first charge refrigerant gas, cordless remote etc complete as required. suitable for single phase 230 V supply and with suitable stabilizer etc complete as required.

2

-

-

... More
Supply,Installation , testing and commissioning of 12TR minimum capacity ceiling suspended indoor ductable units with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan, as per specifications complete with cordless remotes, power wiring, suitable capacity drive motor, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, CPVC drain pipe connections with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including U-trap along with necessary elbows, fittings etc., power/control cabling from power supply, etc complete in all respects as per the technical specifications.

3

-

-

... More
Supply,Installation , testing and commissioning of 13TR minimum capacity ceiling suspended indoor ductable units with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan, as per specifications complete with cordless remotes, power wiring, suitable capacity drive motor, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, CPVC drain pipe connections with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including U-trap along with necessary elbows, fittings etc., power/control cabling from power supply, etc complete in all respects as per the technical specifications.

1

-

-

... More
Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation finished with 7mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating and insulation shall have antimicrobial properties, suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers,Y-Joints, supports, clamps, refnets etc.Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items.Both refrigerant suction and liquid line shall be insulated.

-

-

-

... More
Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/2")

26

-

-

... More
Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/8")

25

-

-

... More
Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/4")

60

-

-

... More
Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/8")

150

-

-

... More
Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/4")

44

-

-

... More
Hard Copper Pipe 18Guage with 19mm thick Insulation ( 5/8")

60

-

-

... More
Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1/2")

130

-

-

... More
Soft Copper Pipe 20Guage with 13mm thick Insulation ( 3/8")

40

-

-

... More
Soft Copper Pipe 20Guage with 13mm thick Insulation ( 1/4")

10

-

-

... More
DX TYPE UNITS - HI WALL SPLIT UNITS Supply, Installation testing and commissioning of minimum 2 TR capacity Hi wall Split air conditioning unit(Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor,outdoor unit and hi wall units for single phase 230 V supply minimum 3star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation ,suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19mm thick closed cell elastomeric insulation as per specification interconnecting indoor & outdoor units with required pipe fittings and accessories like Bends, Tees, reducers, supports finished with an 8 oz canvas cloth covering adhered between two coats of fungicidal protective coating,necessary power/control cabling, suitably supported on trays/ split clamps etc., CPVC condensate drain pipe 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 12mm thick closed cell elastomeric insulation as per specification required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, finished with an 8 oz canvas cloth covering adhered between two coats of fungicidal protective coating suitably supported on trays, clamps etc first charge refrigerant gas R410A/R407C, cordless remote etc complete as required. ,inclusive of all taxes etc. complete as required as per specification/ISHRAE standards.

2

-

-

... More
Supply, installation, testing and commissioning of CPVC drain pipe of suitable dia connecting the drain pan of the indoor units with necessary U-traps, elbows, fittings etc. to nearest drain point, with 9 mm thick closed cell elastomeric insulation finished with 7mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating & insulation shall have antimicrobial properties inclusive of all taxes etc. complete in all respects as per the technical specifications.

100

-

-

... More
Air Distribution network Supply, installation, testing and commissioning of factory fabricated machine made GSS sheet metal ducting complete with neoprene gaskets, elbows, splitter dampers, vanes, hangers, supports etc. for Supply air, Return air, Exhaust Air, Fresh Air as per ducting specifications and with suitable supports using MS angles, channels, rods, anchor bolts, etc to roof /truss as per IS 655 / SMACNA standards , inclusive of all taxes and complete in all respects as per the technical specifications.

-

-

-

... More
20 G

20

-

-

... More
22 G

305

-

-

... More
24 G

295

-

-

... More
Supplying and fixing of 25 mm thick 55kg/m3 density, regular closed cell nitrile rubber insulation finished with 7mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating ,anti-microbial protection along with factory laminated aluminium foil facing.Butt all joints tightly and seal all breaks and joints by adhering a 75 mm wide reinforced aluminium tape,(on duct ) inclusive of all taxes etc. complete in all respects as required by the technical specifications

620

-

-

... More
Supply and fixing of Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1 finished with 7mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, anti-microbial protection , having density 140 kg/m3 insulation using manufacturers recommended adhesive, tapes etc and applications meeting class 0 as per BS 476 Part 6 & 7 and meeting NRC of 0.4 as per ISO 356 and inclusive of all taxes etc. complete in all respects as required by the technical specifications

160

-

-

... More
Supply and fixing of - 25mm thick. Acoustic Insulation of specified thickness of Elastomeric Rubber Insulation manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapour presence of 0.10. - Class "1" Material- etc.

370

-

-

... More
Supply, fixing testing and commissioning of Supply air grilles of extruded aluminium duly powder coated with aluminium volume control damper, fixing supports inclusive of all taxes etc. complete in all respects as per the technical specifications.

5

-

-

... More
Supply, fixing, testing and commissioning of Return air grilles of extruded aluminium duly powder coated without damper, fixing supports inclusive of all taxes etc. complete in all respects as per the technical specifications.

4

-

-

... More
Supply, Installation , testing and commissioning of Aluminium Extruded Fresh air louvers with fresh air damper, bird screen etc. inclusive of all taxes etc. complete in all respects as per the technical specifications.

2

-

-

... More
Supply,fixing, testing and balancing of opposed type volume control dampers of 16 gauge GI sheets to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distributions system inclusive of all taxes etc. complete in all respects as per the technical specifications.

5

-

-

... More
Supply, Installation ,testing & commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for air distribution Networks , inclusive of all taxes etc complete in all respects as per the technical specifications.

4

-

-

... More
Supply , Installation, testing and commissioning of cabinet fans (duct mounted) of 400 CFM - 15 MM OF WG with suitable blower, 3/1 phase direct driven motor of following capacity for exhaust, with starter, active carbon filter ,other accessories etc. complete in all respects as required by the standard specifications. External static pressure mentioned is exclusive of static pressure for Carbon filter considered (Location: ventilated Rooms ) complete in all respects as required by the technical specifications

2

-

-

... More
Supply , Installation, testing and commissioning of cabinet fans (duct mounted) of 100 CFM - 15 MM OF WG with suitable blower, 3 /1 phase direct driven motor of following capacity for exhaust, with starter, active carbon filter ,other accessories etc. complete in all respects as required by the standard specifications. External static pressure mentioned is exclusive of static pressure for Carbon filter considered (Location: ventilated Rooms ) complete in all respects as required by the technical specifications

1

-

-

... More
FIRE HYDRANT & SPRINKLER SYSTEM - Supplying, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required as per the technical specification. (a) Horizontal type, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 2850 lpm at 60m. head conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.

2

-

-

... More
Supplying, Installation, Testing and Commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required as per the technical specification. (a) Horizontal type, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 2850 lpm at 60 m. head conforming to IS 1520. (b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,2x12v 180AH Batteries and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity 300 Litres) with level indicator, By-pass line,MS Piping to diesel tank from engine, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.

1

-

-

... More
Supplying, Installation, Testing and Commissioning of electric driven pressurisation pump ( Jockey Pump )suitable for automatic operation and consisting of following: complete in all respect as required as per the technical specification. (a)Horizontal type, centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 60 m. head conforming to IS 1520. (b) Suitable HP Squrrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads .

2

-

-

... More
Supply, installation, testing and commissioning of pressure gauge 0-200 PSI ( 0 - 14 Kg ) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals, siphon tube and ball valve including fittings, etc. complete as required as per the technical specification.

5

-

-

... More
Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required as per the technical specification.

5

-

-

... More
Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required as per the technical specification.

1

-

-

... More
Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including all drop forged fittings and accessories like elbows, tees, flanges, tapers, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc as required. The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on the wall,ceiling,truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

-

-

-

... More
200 mm dia

27

-

-

... More
150 mm dia

326

-

-

... More
100 mm dia

106

-

-

... More
80 mm dia

126

-

-

... More
65 mm dia

128

-

-

... More
50 mm dia

92

-

-

... More
40 mm dia

235

-

-

... More
32 mm dia

35

-

-

... More
25 mm dia

398

-

-

... More
Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 / 1239 including drop forged fittings like elbows, tees flanges,reducers, tapers, nuts bolts, gaskets etc. conforming to IS standards in ground at minimum depth of 1 m, including excavation & providing cement concrete blocks as supports, anticorrosive wrapping coating minimum 4 mm thickness as per IS10221, refilling the trench etc. of following sizes complete as required as per the technical specification.

-

-

-

... More
150 mm dia

142

-

-

... More
80 mm dia

4

-

-

... More
Supply, installation, testing and commissioning of dual plate non-return valve of following sizes conforming to IS : 5312 complete with CI body, rubber gasket, GI bolts, nuts, washers etc. as required as per the technical specification.

-

-

-

... More
150 mm dia

5

-

-

... More
100 mm dia

1

-

-

... More
65 mm dia

2

-

-

... More
Supply, installation, testing and commissioning of butterfly valve PN 16, with Cast iron body, Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following sizes as required as per the technical specification.

-

-

-

... More
200 mm Dia

1

-

-

... More
150 mm dia

15

-

-

... More
100 mm dia

7

-

-

... More
80 mm dia

6

-

-

... More
65 mm dia

2

-

-

... More
40 mm dia

4

-

-

... More
Providing, Installation, testing and commissioning of Y strainer with CI body, 3 mm perforated SS screen, flanged end connection, of following size confirming to IS specifications complete with gaskets, seal and accssesories as required as per the technical specification.

-

-

-

... More
200 mm dia

3

-

-

... More
80 mm dia

2

-

-

... More
Supply,installation,testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,Chain etc required as per the technical specification.

16

-

-

... More
Supplying and fixing First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per the technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe

11

-

-

... More
Supplying and fixing 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required as per the technical specification.

32

-

-

... More
Supplying & fixing 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per the technical specification.

16

-

-

... More
Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.

16

-

-

... More
Supply, installation, testing and commissioning of Fire brigade collective breaching with 4 nos. of 150 mm flanged out let connection and built in check valves complete as required as per the technical specification.

3

-

-

... More
Supply, installation, testing and commissioning of Air release valve 25 mm dia. complete as required as per the technical specification.

3

-

-

... More
Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, GI pipe of required size, flanges, orifice plate, gasket etc. complete as required as per the technical specification..

1

-

-

... More
Providing, fixing, testing & commissioning of sprinkler of the following type : Standard response, standard coverage sprinkler, pendant type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C.;including cost of rosette plate complete as required as per the technical specification.

86

-

-

... More
Standard response, standard coverage sprinkler, upright type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. complete as required as per the technical specification.

172

-

-

... More
Early suppression fast response sprinkler, pendant type sprinkler ;3/4" NPT, K -16.8, Chrome Finish; operating temperature at 74 deg. C. including cost of rosette plate complete as required as per the technical specification.

65

-

-

... More
Supply, installation, testing and commissioning of 1m unbraided flexible drop to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible drop with nipple, reducer, square bar and brackets etc complete as required complete as required as per the technical specification.

143

-

-

... More
Supply, installation, testing and commissioning of UL listed flow switch which shall be of Paddle type with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The material of the construction of the paddle shall be of stainless steel or copper alloy. The body of the flow switch shall be water proof with IP55 class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 15Kg/cm2 and operating pressure ranging from 3.5kg/cm2 to 10Kg/cm2. complete as required as per the technical specification.

6

-

-

... More
PORTABLE FIRE EXTINGUISHERS - Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2006 with ISI mark. complete as required as per the technical specification.

10

-

-

... More
Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas. complete as required as per the technical specification.

16

-

-

... More
Providing and fixing initially fully charged Portable Fire Extinguisher of  9 L capacity, foam extinguisher confirming to IS 15683:2006 and complete with necessary accessories as required as per the technical specifications.

1

-

-

... More
Supply and installation of ISI marked Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

1

-

-

... More
FIRE DETECTION AND ALARM SYSTEM - Supply, installation, testing and commissioning of Addressable type Multi Detector (photoelectric cum rate of rise temperature type) complete with all accessories like base. base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. Shall be UL listed/ FM Approved.complete as required as per the technical specification.

183

-

-

... More
Supply, installation, testing and commissioning of addressable type heat detector complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. Shall be UL listed/ FM Approved.complete as required as per the technical specification.

23

-

-

... More
Supply, installation, testing and commissioning of Addressable type Manual Call Point Re-setable type via special key (non-breaking glass type)complete with push button, enclosed in box with provision for cable or conduit coupling. The unit to be painted fire red outside, white inside and having illustrations of operational instructions in case of fire. Shall be UL listed/ FM Approved.complete as required as per the technical specification.

10

-

-

... More
Supply, installation, testing and commissioning of loop powered wall sounder beacon at different locations complete for both audio and visual indication with all fixing accessories, etc. under false ceiling, roof, wall, etc, with a time delay of max 30sec, interconnecting lo loop cable complete as required. Shall be UL listed/ FM Approved.complete as required as per the technical specification.

10

-

-

... More
Supply, installation, testing and commissioning of addressable Loop Isolators to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required. Shall be UL listed/ FM Approved.complete as required as per the technical specification.

14

-

-

... More
Supply, Installation, Testing & Commissioning of 16 bit intelligent Addressable Fire Alarm Control Panel with suitable number of loops ( each loop accessing at least 250 detectors ) including battery backup. The panel shall be microprocessor based with its own micro controller, memory, communication module and fire device loop interface cards for indicating devices and should also be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches when ever any Alarm is triggered. The panel shall have 54 Ah SMF Battery, Keypad operation, L C D unit to indicate Fire / Fault Signal of individual unit,etc complete in all respects. The panel shall be UL listed/ FM Approved.complete as required as per the technical specification. The Panel shall also have Logic hardware and software built into it for time delay operation of hooter and others as follows : (a) programming software for the system, (b) automatic system test activates, (c) detector sensitivity adjustments, (d) alarm verification, (e) Alpha/numerical display, (f) provision to connect to PCs and external printers

1

-

-

... More
Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring purpose and send the signal from a flow switch to the alarm panel for initiating alarm when flow occurs. Shall be UL listed/ FM Approved.complete as required as per the technical specification.

6

-

-

... More
Supply and laying of 2x 1.5sq.mm armoured Copper FRLSZH cable ISI marked with proper clamping, supports and terminations appropriately above ground, on walls and ceilings etc. complete as required as per the technical specification.

2175

-

-

... More
Supply and laying of 25mm dia PVC conduit along with accessories like PVC bends,couplers,junction box,fastners, iron staples/saddles/screws,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit etc. complete as required as per the technical specification.

57

-

-

... More
Supply, installation, testing and commissioning of public address and talk back system consisting of multiple zone public address cum talkback console with mike and selector. multiple channel talk back master control panel with 2x16 character LCD display,power supply, battery charger, battery housing, 80 W PA & mic, multiple channel selector with all call and mic on. The console shall be provided with suitbale capacity amplifier (min 80W) and suitable capacity battery (min 12V) all assembled in a cabinet and meeting the technical specifications. The rate shall include the cost of all the necessary accessories as required for the operation of the system.

1

-

-

... More
Supply, installation, testing and commissioning of wall mounted talk back unit including all necessary accessories complete as required as per the technical specification..

8

-

-

... More
Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.

8

-

-

... More
CO2 Liner heat detection/trace tube PANEL/modular FLOODING SYSTEM FOR ELECTRICAL PANELS consisting of CO2 cylinders with weight calculated on the basis of volume of single largest compartment within the panel. UL listed trace tube of required design length, for the 9 L cylinder (One number), also consisting of master control unit with digital display, load cell, discharge hooter/flashers, pressure gauges, pressure switches for low pressure/discharge indications & interlocks with fire alarm system of the premises & all accessories of complete functionality of system, complete as required as per the technical specification.

1

-

-

... More
SIGNAGE - Supply and installation of glow signage (photoluminescent)of "3M" Make such as Fire Duct/Fire Lift/Staircase signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

18

-

-

... More
Supply and installation of glow signage (photoluminescent)of "3M" Make FIRE ASSEMBLY POINT of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

2

-

-

... More
Supply and installation of glow signage (photoluminescent)of "3M" Make "FIRE ORDER" of standard size (500*800 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

6

-

-

... More
Supply and installation of glow signage (photoluminescent)of "3M" Make such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

17

-

-

... More
Supply and fixing of Fire Emergency Evacuation Plan (Color) Printed in Photo Paper of Size A2 sandwitched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification.

6

-

-

... More
ELECTRICAL ITEMS- Main Fire Pump Panel Supply of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with bus bars extendable on both sides, including all the necessary internal wiring , suitable spreader etc. The panel shall be fabricated from a firm having CPRI certification with test certificates (required for short circuit rating, temperature rise test and IP classification) with following switchgears, metering instruments and accessories etc.complete in all respect as per drawing and technical specification. The panel shall be with top entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram.,INCOMER: 320A, FP SDFU- 1 No. INSTRUMENTS- (0 to 500 )V analogue type Voltmeter for 3 phase, 4 wire operation with selector switch - 1 set, (0 to 400A) analogue type ammeter for 3 phase, 4 wire operation - 3 set, Phase indicating lamps, LED type, RYB - 1 Set, ON, OFF, Trip indicating lamps, LED type, RYB with 3 nos. control SP MCB - 1 Set, 320/5A, Class 1.0, 15VA, Cast Resin CT for metering - 1 Set, BUSBARS:320 Amp TPN bus bars of high conductivity electrolytic quality Aluminium alloy. OUTGOING: Electrical Fire Pump, 125A TPN SDFU- 2 No. , Star Delta starter of suitable rating for 415V, 50Hz, 3 phase for main electrical fire pump(approx. 55 kW) with kW in accordance with the main electric pump. The starter shall have ON, OFF push button, ON, OFF indication lamp complete with all accessories and internal wiring required for automatic and manual operation as required. - 2 No's , Jockey Pump- 2 No, 50A, TP, SDFU - 2 No., Star Delta starter of suitable rating for 415V, 50Hz, 3 phase Jockey pump (approx. 11KW). The starter shall have ON, OFF push button, ON, OFF, Trip LED indication lamp, thermal over load relay, single phase preventer, complete with all accessories and internal wiring required for automatic and manual operation - 2 No , Spare: 100A, TPN, SDFU- 1 No. , 63A, TPN, SDFU - 2 Nos. , Diesel Engine Control - 1 No. , Each Diesel engine control consisting of: 25A DP C curve control MCB, 25A On/off control switch - 2 No. , Auto / manual selector switch, 3 attempt starting device, push button etc., All required timers, relays, fuses and accessories for automatic operation of diesel engine. Indication lamp for high water temperature, engine fail to start, engine On indication, high/low lube oil pressure. Necessary control wiring for start / stop solenoid, line / oil pressure switch, temperature switch, pressure switch to fire pump panel, diesel engine control panel to fire pump panel etc. Battery Charger suitable for 12 V / 24 V DC with boost and trickle selector switch, 0 -15 V / 0 - 30 V DC volt meter, 0 - 20 A DC Ammeter - 02 No. 6 panel annunciation window for fault indication with hooter, accept & reset push button, separate hooter for Diesel /electrical pump on running condition - 1 No, The system shall include all accessories to control the operation of main electric pump, diesel pump, jockey pump as per the operating sequence for the fire fighting system indicated in the technical specification . The battery charger and all its components should be housed inside the main fire pump pane The Scope of works also includes LT power & control cabling including the GI ladder type cable tray & necessary MS supports.etc complete in all respects as per technical specification.

6

-

-

... More
CABLES AND CABLING Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date, complete in all respects as per technical specification.

-

-

-

... More
3C 95 Sq.mm Al

40

-

-

... More
3 C 10 Sq.mm Al

40

-

-

... More
4C 2.5 Sq.mm Al

50

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete in all respect as per technical specification.

-

-

-

... More
3C 95 Sq.mm Al

8

-

-

... More
3.5 C 35 Sq.mm Al

8

-

-

... More
4C 2.5 Sq.mm Al

8

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc complete in all respect as per technical specification.

-

-

-

... More
Upto 35 sq. mm

4

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

4

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc complete in all respect as per technical specification.

-

-

-

... More
Upto 35 sq. mm

4

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

4

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface complete in all respect as per technical specification.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

5

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

5

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe complete in all respect as per technical specification.

-

-

-

... More
Upto 35 sq. mm

5

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

5

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

80

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

40

-

-

... More
Fabrication, supply and installation of following size of ladder type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and painting etc as required

-

-

-

... More
150 MM WIDTH X 75 MM DEPTH X 2 MM THICK

10

-

-

... More
300 MM WIDTH X 75 MM DEPTH X 2 MM THICK

15

-

-

... More
EARTHING Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. complete in all respect as per technical specification.

-

-

-

... More
4 SWG Cu

90

-

-

... More
10 SWG Cu

100

-

-

... More
25*3 Cu Strip

20

-

-

... More
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc.complete in all respect as per technical specification (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 25*3 Cu Strip

100

-

-

... More
SUPPLY OF ELEVATOR Design, fabrication, supply of machine room less electric traction type , Stainless steel 10 Pax passenger elevator (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc.) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purcahsers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories,brailiy buttons,audio announcement along with prerecorded message as approved by Engineer-in-Charge.The traction motor of the elevator shall be of gearless type and placed inside the elevator shaft complete as per technical specification. Having automatic centre opeming SS door stainless steel car enclosure provided with stainless steel handrails on Three sides, Granite flooring as applicable in accordance of following details:-3 stops & 3 openings and entrance & exit at same side and suitable for travel height of 8.9 mtrs. (Shaft Size1900mm (width) x 2100mm (depth) ) with door opening of 800mm (width) and 2000 mm (height) . The equipment should be BMS compatible.All electrical components with wiring from the single point power supply at top landing .All fabrication and procedures shall confirm to relevant IS standards.

2

-

-

... More
ITC of Elevator Installation ,Testing and Commisioning of 10 passenger Lift Stainless steel Elevator with SS door to suit the shaft size and also to provide adequate structural steel supports,as required for the safe operation of the equipment. All procedures should conform to relevant standards and as per technical specification.

2

-

-

... More
CCTV System Supply, Installation,Testing and Commissioning of 4MP Indoor Dome PoE camera with 1/2.8 inch CMOS sensor, Varifocal lens - 3 to 10mm, IR range - 20m, H.265, ONVIF, Minimum illumination - 0.05 lux (B/W), 0.0 lux (IR), White balance, Backlight compensation, Motion detection, Tamper detection, One way audio, MicroSD card slot, Certifications - CE / EN, FCC and UL with all accessories as required at site as per specification.

7

-

-

... More
Supply, Installation,Testing and Commissioning of 4MP Bullet PoE camera with 1/2.9 inch CMOS sensor, Varifocal lens - 2.8 to 12mm, IR range - 30m, IP66, H.265, ONVIF, Minimum illumination - 0.05 lux (B/W), 0.0 lux (IR), White balance, Backlight compensation, Motion detection, Tamper detection, One way audio, MicroSD card slot, Certifications - CE / EN, FCC and UL with all accessories as required at site as per specification.

15

-

-

... More
Supply, Installation, Testing and Commissioning of CCTV central control equipment with capacity of 32 cameras, RAID5 with 30 days of archivings (Contractor to provide storage and calculations to justify the record duration) - with required HDDs and all required hardware, including necessary cabling with all accessories required at site complete as per specification. The video recording will be at 15fps in minimum HD resolution.

1

-

-

... More
Supply, Installation, testing and commissioning of 42" commercial display, 24/7, full HD, with HDMI and USB ports with all accessories required at site complete as per specification.

1

-

-

... More
Supply, installation, testing and commissioning of 15U Network Rack along with all necessary hardware and accessories, etc. required at site complete as per specification.

1

-

-

... More
Supply, Fixing, Testing and commissioning of size - 25mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

1500

-

-

... More
Access Control Supply, installation, testing and commissioning of Biometric card reader along with all necessary accessories and cabling as required at site complete as per specification.

3

-

-

... More
Supply, installation, testing and commissioning of Single door EM lock along with Emergency door release all necessary accessories and cabling as required at site complete as per specification.

3

-

-

... More
Supply, installation, testing and commissioning of Exit Push button along with all necessary accessories and cabling as required at site complete as per specification.

3

-

-

... More
Telephone System - EPBAX Supply, Installation, Testing and Commissioning of IP based EPABX with 1 PRI line and 8 analogue extensions along with operator console, 20 pair MDF with krone modules, and all required accessories and cabling, as required at site complete as per specification.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Analog telephone as per specification.

5

-

-

... More
Passive Supply, Laying, Testing and Commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site as per specification.

2000

-

-

... More
Supply, Installation,Testing and Commissioning of CAT6 24 port patch panel (data/voice) with shutter fully loaded, with all accessories required at site including termination complete as per specification.

3

-

-

... More
Supply, Installation, Testing and Commissioning of CAT6 information Outlet, RJ 45 with all accessories required at site including termination complete as per specification

11

-

-

... More
Supply, Installation, Testing and Commissioning of of Single / Dual Shuttered Face Plate with metal backbox and all accessories required at site complete as per specification.

11

-

-

... More
Supply, Installation, Testing and Commissioning of Patch Cord - 2m with end termination for both data and voice with all accessories required at site complete as per specification.

23

-

-

... More
Supply, Installation, Testing and Commissioning of Patch Cord - 1m with end termination for both data and voice with all accessories required at site complete as per specification.

23

-

-

... More
Switches Supply, Installation, Testing and Commissioning of Layer 2 - 24 Port PoE switch with 2 nos of SFP ports along with all accessories required at site complete as per specification.

1

-

-

... More
Supply, Installation, Testing and Commissioning of 1G SFP module - LC type, SM along with all accessories required at site complete as per specification

2

-

-

... More
Supply, Installation, Testing and Commissioning of Layer 2 - 24 Port switch with 2 nos of SFP ports along with all accessories required at site complete as per specification.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Layer 2 - 8 Port PoE switch with 2 nos of SFP ports along with all accessories required at site complete as per specification.

1

-

-

... More
SIGNAGES Supply, Installation, Testing and Commissioning of External Fascia sign board with content " KSFDC " in single language( English) at specified locations (approx. installation height - 20m) made of PU Coated Channel Letters with 2.5 feet height and 5" thickness and width in proportionate to be made with 1.6 mm aluminium sheet Letter front face is made up of 5mm solid acrylic 040 with 3M vinyl and aluminium trim cap. The channel letters will be fixed either on the angle iron bend letters with screws or rivets of suitable size angle iron or directly screwed/Anchor bolted to the RCC using anchor fastener of suitable length as per the site conditions and as approved by engineer in charge. Letters should be lit static white LED of approved make with required power supply.The system has to be wired to a outdoor light timer switch or similar consisting of MCB, timers, contactors of suitable rating and all accessories including wiring as required etc. All metal parts are to be painted with 2 coats of epoxy primer and two coats of epoxy paint.The rate shall includes cost and conveyance of all materials, structural supports (all the supports as required to install the signage from the available fascia / structural members), labour charges, scaffolding, lead, lift, etc complete as per technical specification.

1

-

-

... More
Wayfinding / Facility / Service / Utility Signs / Statutory Signs Supply, Installation, Testing and Commissioning of Ceiling / Wall Mounted Signage of required size fabricated with MS 1/2" Tube profile and Fascia with translucent / colored / block-out / white Cast vinyl applied on 3mm thick Acrylic sheet 040. A uniform Border frame shall be provided to the profile with 2mm black powder coated aluminim sheet.

10

-

-

... More
Supply, Installation, Testing and Commissioning of Fire Emergency Evacuation Plan (Color) Printed in High quality UV printed film of Size A3, sandwitched in 5mm clear acrylic sheets fixed using SS Studs and other accessories as required at site complete as per specification.

8

-

-

... More
Supply, Installation, Testing and Commissioning of Sticker type signage at site in proper line and level. The signage letters shall be made with premium quality vinyl sheet of approved colour, pasted on “3M” make self-adhesive film of approved colour, including supply of all material labour etc. required for proper completion of work.

25

-

-

... More
Supply, Installation, Testing and Commissioning of direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2mm thick with area exceeding 0.9 sqm supported on mild steel angle iron post 75mm x 75mm x 6mm - 2 nos, firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete - 45cm x 45cm x 60cm below ground level as per specification.

5

-

-

... More
Supply, Installation, Testing and Commissioning of Fire Exit LED Sign of reputed make with Rechargable Backup Battery (2+ Hours) with Aluminum Alloy Extruded Section with Powder Coating in Grey Colour. The content / artwork shall be etched in 10mm clear acrylic with prescised matching of colour to Green (Brilliant Green: IS Shade 221) with all accessories in complete as required at site as per specification.

8

-

-

... More
Supply, Installation, Testing and Commissioning of Edge Lit Sign of size 100mm x 100mm for Seat Numbers made up of 22 SWG CRCA Black powder coated housing and lit using LED of reputed make with row alphabets and numbers in Clear acrylic of thickness 5mm with all accessories as required at site as per specifications.

89

-

-

... More
Supply Installation Testing and Commissioning of LED Step Light of size 1.35m in length made up of 22 SWG CRCA Black powder coated housing and lit using LED of reputed make with row alphabets and numbers with clear acrylic sheet with all accessories as required at site as per specifications.

46

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.