Kerala Police Housing And Construction Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KPHCC_667937_1Bid Award Id
ViewTender No
NIT No.255/KPHCC/2023-2024Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Check List enlisting the brands of civil, water supply, sanitary and electrical items to be used for the work
BOQ Items
15.7.4
Demolishing brick work manually / by mechanical means including stacking of
serviceable material and disposal of unserviceable material within 50 metres lead as
per direction of Engineer-in-Charge.In cement mortar
2
-
-
2.8.1
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means
in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift up to 1.5 m, including
getting out the excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.All kinds of soil
55.1
-
-
4.1.8
Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4
coarse sand : 8 graded stone aggregate 40 nominal size)
9.89
-
-
5.1.2
Providing and laying in position specified grade of reinforced cement concrete,
excluding the cost of centering, shuttering, finishing and reinforcement - All work up
to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm
nominal size
16.86
-
-
5.3
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up
to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window
sills, staircases and spiral stair cases up to floor five level excluding the cost of
centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse
sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
15.93
-
-
5.9.1
Centering and shuttering including strutting, etc. and removal of form
for:Foundations, footings, bases of columns, etc for mass concrete
108.16
-
-
5.9.3
Centering and shuttering including strutting, etc. and removal of form for:Suspended
floors, roofs, landings, balconies and access platform
87.33
-
-
5.9.5
Centering and shuttering including strutting, etc. and removal of form for:Lintels,
beams, plinth beams, girders bressumers and cantilevers
38.09
-
-
5.9.19
Centering and shuttering including strutting, etc. and removal of form for:Weather
shade, Chajjas, corbels etc., including edges
13.83
-
-
5.9.16.1
Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and wallsUnder 20 cm wide
37.7
-
-
5.9.2
Centering and shuttering including strutting, etc. and removal of form for:Walls (any
thickness) including attached pilasters, butteresses, plinth and string courses etc.
17.49
-
-
2.25
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
40.69
-
-
50.2.25.1
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction
of site Engineer-in-charge
74.24
-
-
5.22A.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete above plinth level.Thermo - Mechanically
Treated bars of grade Fe-500D or more
3606.68
-
-
50.6.2.1
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm
or nearest available size confirming to IS 2185 part I of 1979 for foundation and
plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
2.92
-
-
6.3.2
Brick work with common burnt clay machine moulded perforated bricks of
classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up
tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With Modular
bricks
29.12
-
-
6.13.2
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar
1:4 (1 cement : 4 coarse sand)
39.6
-
-
4.17
Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse
sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry
brick ballast 40 mm nominal size, well rammed and consolidated and grouted with
fine sand, including finishing the top smooth.
21.9
-
-
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
364.39
-
-
13.7.2
12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1
cement : 4 fine sand)
95.83
-
-
13.16.1
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
95.83
-
-
21.1.1.2
Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at junctions,
i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminnium snap beading for
glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash
fasteners to be paid for separately):
For fixed portionPowder coated aluminium (minimum thickness of powder coating
50 micron)
75.18
-
-
21.1.2.2
For shutters of doors, windows & ventilators including providing and fixing hinges /
pivots and making provision for fixing of fittings wherever required including the
cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for
separately)Powder coated aluminium (minimum thickness of powder coating 50
micron)
68
-
-
21.3.1
Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of Engineer - in -Charge. ( Cost of
aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm
thickness
15.5
-
-
21.2.2
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer
or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling
fixed in aluminum doors, windows shutters and partition frames with C.P. brass /
stainless steel screws etc. complete as per architectural drawings and directions of
Engineer - in- Charge.Pre- laminated particle board with decorative lamination on
both sides
6
-
-
9.48.2
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with
M.S. flats, square or round bars etc. including priming coat with approved steel
primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
84
-
-
9.121
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection
90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of
30 mm thickness. The laminated shall be moulded with fire resistant grade
unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm
thick and shall be filled with suitable wooden block in all the three legs. The frame
shall be covered with fiber glass from all sides. M.S. stay shall be provided at the
bottom to steady the frame.
20.4
-
-
9.122.1
Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced
Plastic (FRP) panelled door shutter of required colour and approved brand and
manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and
suitable blocks of seasoned wood inside at required places for fixing of fittings, cast
monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,
including fixing to frames.
7.56
-
-
13.48.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using
primer as per manufacturers specifications:Two or more coats applied on walls @
1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10
sqm
442.84
-
-
13.61.1
Painting with synthetic enamel paint of approved brand and manufacture to give an
even shade:Two or more coats on new work
10.13
-
-
8.2.2.2
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias
and similar locations, of required size, approved shade, colour and texture laid over
20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with
white cement, mixed with matching pigment, epoxy touch ups, including rubbing,
curing, moulding and polishing to edges to give high gloss finish etc. complete at all
levels.Area of slab over 0.50 sqm
9.23
-
-
8.3.2
Providing edge moulding to 18 mm thick marble stone counters, vanities etc.,
including machine polishing to edge to give high gloss finish etc. complete as per
design approved by Engineer -in-Charge.Granite work
30.75
-
-
11.41.2
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by
the manufacturer) with water absorption less than 0.08% and conforming to IS :
15622, of approved make, in all colours and shades, laid on 20 mm thick cement
mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement
and matching pigments etc., complete.Size of Tile 600 x 600 mm.
100.7
-
-
11.48.2
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout
mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg
of resin per kg). including filling /grouting and finishing complete as per direction of
Engineer-in-charge.Size of Tile 600x600 mm
100.72
-
-
10.28: Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,
channels, plates etc., including welding, grinding, buffing, polishing and making
curvature (wherever required) and fitting the same with necessary stainless steel nuts
and bolts complete, i/c fixing the railing with necessary accessories & stainless steel
dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the
side of waist slab with suitable arrangement as per approval of Engineer-in-charge,
(for payment purpose only weight of stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts, fasteners etc.)
125
-
-
50.10.1
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)
trusses etc., including cutting, hoisting,fixing in position and applying a priming coat
of approved steel primer, including welding and bolted with special shaped washers
etc. complete
40
-
-
OD16478/2023-2024
Providing and fixing 3mm thick acrylic letters and emblems fixed on ACP sheet etc.
complete. (Cost of ACP paid seperately)
1.5
-
-
OD16479/2023-2024
Providing and fixing name board of size 40*15 cm with sticker pasted on 3mm thick
acrylic sheet etc. complete
6
-
-
OD16480/2023-2024: installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:<br>a) Providing, fabricating and supplying and fixing panels of aluminium composite<br>panel cladding in pan shape in metalic colour of approved shades made out of<br>4mm thick aluminium composite panel material consisting of 3mm thick FR grade<br>mineral core sandwiched between two Alumini um sheet(each0.5mm thick). The<br>aluminium composite panel cladding sheet shall bcoil coated, with Kynar<br>500based PVDF / Lumiflon based fluoropolymeresin coating of approved colour<br>and shade on face # 1 and polymer (Service) coating on face # 2 as specified using<br>stainless steel screws, nuts,
bolts, washers, cleats, weather silicone sealant, backer<br>rods etc.<br>bThe fastening brackets of Aluminium alloy 6005 T5 / MS with Hot DiGalvanised<br>with serrations and serrated washers to arrest the wind loamovement, fasteners,<br>SS 316 Pins and anchor bolts of approved make in SS
316, Nylon separators to<br>prevent bi-metallic contacts all complete required
to perform as per specification<br>and drawing The item includes cost of all
material & labour component, the cost of<br>all mock ups at site, cost of
all samples of the individual components for testing in<br>an approved
laboratory, field tests on the assembled working curtain wall with aluminium
composite panel cladding, cleaning and protection of the curtain wall<br>with
aluminium composite panel cladding till the handing over of the building
for<br>occupation. Base frame work for ACP cladding is payable under the relevant<br>aluminium item.s The Contractor shall provide curtain wall with
aluminium<br>composite panel cladding, having all the performance
characteristics all complete<br>, as per the Architectural drawings, as per item
description, as specified, as per the<br>approved shop drawings and as directed
by the Engineer-in-Charge.<br>However, for the purpose of payment, only the
actual area on the external face of<br>the curtain wall with Aluminum
Composite Panel Cladding (including width of<br>groove) shall be measured in
sqm. up to two decimal places.
1
-
-
WATERSUPPLY AND SANITARY
-
-
-
17.2.1
Providing and fixing white vitreous china pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including
flush pipe, with manually controlled device (handle lever), conforming to IS : 7231,
with all fittings and fixtures complete, including cutting and making good the walls
and floors wherever required:W.C. pan with ISI marked white solid plastic seat and
lid
2
-
-
17.7.9
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32
mm C.P. brass waste of standard pattern, including painting of fittings and brackets,
cutting and making good the walls wherever require:White Vitreous China Surgeon
Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with
elbow operated levers ISI marked
2
-
-
18.51.1
Providing and fixing C.P. brass long body bib cock of approved quality conforming to
IS standards and weighing not less than 690 gms.15 mm nominal bore
2
-
-
18.53.1
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of
approved quality conforming to IS: 893115 mm nominal bore
6
-
-
18.58.2.1
Providing and fixing PTMT grating of approved quality and colour.
Rectangular type with openable circular lid150 mm nominal size square 100 mm
diameter of the inner hinged round grating
2
-
-
50.17.1.1
Supplying and fixing Stainless steel soap dish including cost of materials and labour
charges etc complete as per the direction of site Engineer-in-charge.
2
-
-
50.17.1.3
Supplying and fixing CP Towel rod 60cm or nearest available length including cost of
materials and labour charges etc complete as per the direction of site Engineer-incharge.
2
-
-
50.17.1.4
Supplying and fixing CP Health faucet good quality including cost of materials and
labour charges etc. complete as per the direction of site engineer-in-charge.
2
-
-
50.18.7.3.2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm
dia 10Kgf/ cm2- Internal work- Exposed on wall
10
-
-
50.18.7.4.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm
dia 10Kgf/cm2- Internal work - Exposed on wall
5
-
-
18.7.3
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded
fittings including fixing the pipe with clamps at 1.00 m spacing. This includes
jointing of pipes & fittings with one step CPVC solvent cement and testing of joints
complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25
mm nominal outer dia pipes
15
-
-
50.18.7.6.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm
dia 10 Kfg/cm - Internal work- Exposed on wall
10
-
-
18.17.2
Providing and fixing gun metal gate valve with C.I. wheel of approved quality
(screwed end) :32 mm nominal bore
1
-
-
18.48
Providing and placing on terrace (at all floor levels) polyethylene water storage tank
:ISI 12701 marked, with cover and suitable locking arrangement and making
necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1000
-
-
50.18.8.7.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes with one step PVC solvent cement and
testing of joints complete as per direction of Engineer-in-Charge. Concealed work
including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
9
-
-
50.18.8.9.2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes with one step PVC Solvent cement and
testing of joints complete as per direction of Engineer-in-Charge. Concealed work,
including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
20
-
-
50.18.9.9.1
Providing and fixing PVC pipes includings jointing of pipes with one step PVC
solvent cement, trenching, refilling & testing of Joints complete as per direction of
engineer in charge.110 mm dia 6Kgf/cm2
15
-
-
50.18.9.22.1
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 110 mm dia Elbow
2
-
-
50.18.9.22.2
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
2
-
-
50.18.9.22.3
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement-110 mm dia Door Elbow
5
-
-
50.18.9.22.8
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,
including jointing with PVC solvent cement -110 mm dia Vent cowl
2
-
-
50.18.9.22.11
Providing and fixing PVC moulded fittings/accessories for Rigid PVC
pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
3
-
-
18.21.1.1
Providing and fixing uplasticised PVC connection pipe with brass unions: 30 cm length15 mm nominal bore
4
-
-
18.18.3
Providing and fixing ball valve (brass) of approved quality, High or low pressure,
with plastic floats complete:25 mm nominal bore
1
-
-
OD16481/2023-2024
Supplying and installing ready made RCC Septic tank including the cost of carriage,
placing at the level below ground level as specified as per the direction of engineer in
charge<br>3000 LTR
capacity(50 users) including soak pit etc complete
Details of cost for 1 no
1
-
-
Electrical work
-
-
-
1.10.1
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A
9
-
-
1.10.2
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B
12
-
-
1.10.3
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
8
-
-
1.11
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way
modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1
-
-
1.17.1
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x
1.5 sq. mm
40
-
-
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X
1.5 sq.mm
60
-
-
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
90
-
-
1.17.21
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
4 sq. mm
15
-
-
1.17.30
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
6 sq. mm
10
-
-
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
70
-
-
1.21.2
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.25 mm
40
-
-
1.25
Supplying and fixing two module stepped type electronic fan regulator on the existing
modular plate switch box including connections but excluding modular plate etc. as required.
5
-
-
1.27.1
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.1 or 2 Module
(75mmX75mm)
4
-
-
1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket
outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be
used in non residential buildings).
5
-
-
1.32
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular
socket outlet and 15/16 amps modular switch, connection etc. as required.
4
-
-
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden
block including connection etc as required.
18
-
-
1.56
Supplying and fixing suitable size Gl box with modular plate and cover in front on
surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket
outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light
plugs to be used in non residential buildings).
5
-
-
1.58
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
4
-
-
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.Single pole
7
-
-
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete
etc. as required.
5
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
1
-
-
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240
volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps
1
-
-
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per
IS 732 as required.
5
-
-
90.4.5.4
Supply, Installation, testing and commissioning of ceiling fan of following sizes
including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm
FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub
meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding
suitable for 230V/240V single phase AC supply
4
-
-
90.10.3.15
Supply and Fixing the following modular switches & accessories in the existing front
plates and giving necessary connections as required (RoHS compliant )32A DP
switch with indicator
1
-
-
90.10.3.33
Supply and Fixing the following modular switches & accessories in the existing front
plates and giving necessary connections as required (RoHS compliant )25A 3pin
Shuttered socket
1
-
-
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with
wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
5
-
-
OD13631/2023-2024
Labour for wireman
1
-
-
OD13632/2023-2024
Supply and fixing of 8 inch PVC Exhaust fan including all accessories, working on
230 V A/C. make Havells or equivalent
4
-
-
OD13636/2023-2024
Supply and fixing of 12W led die cast aluminium housing bulk head IP54 with 1000
Lumens all accessories ,electrical connections.including fixing materials required.
make-philips/wipro/havells/luker(LBKOVSL04) or equivalent
3
-
-
OD16389/2023-2024
Supply installation testing and commissioning of 4feet 20W led battan with 2000
Lumens ,25000 burning hours, and all accessories electrical connections as required.
make-philips/wipro/havells or equivalent
7
-
-
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as
required.
1
-
-
OD13637/2023-2024
Supply installation testing and commissioning of 2feet 10W led batten with 1000
Lumens ,25000 burning hours,all accessories ,electrical connections.including fixing
materials required. make-philips/wipro/havells or equivalent
2
-
-
OD14309/2023-2024
Supply, Installation, testing and commissioning of ceiling fan of following sizes
including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm
FRLS PVC insulated, copper conductor, single core cable etc. as required. 900mm
sweep - ceiling fan complete with service value minimum 4.0(cub
meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding
suitable for 230V/240V single phase AC supply
1
-
-
OD14312/2023-2024
supply testing and fixing of 9w fancy light with led bulb including connection etc. as
required (make -luker ,wipro or equivalent)
4
-
-
OD14311/2023-2024
supply & Installation of dust and vermin proof, wall mounting, single Phase
Meter Box suitable for fixing KSEB meter, fuse units,isolator etc, hinged door
construction for the front side with compartments if necessary, providing vision panel
for the meter compartment, knock outs for cable entry and exit with the following. 32
A, 230V fuse unit- 1 nos 32 A, 230 V Neutral Link- 1 no,2p 40A isolator
1
-
-
OD13638/2023-2024
Supply and fixing 9 W LED Bulb make philips/Govt approved reputed brand
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements