Kerala Electrical And Allied Engineering Company Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Electrical And Allied Engineering Company Limited - KEL Tender

Eprocure
Opening Date20 Jul 2019
Closing DateCancelled
Tender Amount₹ 3,11,66,700 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
15.3 . Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

4.101

-

-

... More
15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. In cement mortar

81.973

-

-

... More
15.18. Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

3000

-

-

... More
15.19 Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.

541.8

-

-

... More
15.28.1 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of : G.S. Sheet

840

-

-

... More
15.60 Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

113.761

-

-

... More
15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm

1098

-

-

... More
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

9.121

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

24.343

-

-

... More
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

63.11

-

-

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete

19.001

-

-

... More
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers

5.7

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more

618.45

-

-

... More
50.6.1.7. Solid block masonry using pre cast solid blocks (Factory made) of size 40X20x15cm or nearest available size confirming to IS 2185 part of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 (1 cement: 6 coarse sand ) etc complete

6.84

-

-

... More
50.6.1.8. Solid block masonry using pre cast solid blocks (Factory made) of size 40X20x15cm or nearest available size confirming to IS 2185 part of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 (1 cement: 6 coarse sand ) etc complete

14.25

-

-

... More
13.1.1- 12mm cement plaster of mix 1:4 (1 cement : 4 fine sand)

228.002

-

-

... More
14.1.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead: With cement mortar 1:4 ( 1 cement : fine sand)

26.16

-

-

... More
14.2.1 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for hold fasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm, with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meters lead: Door chowkhats

44

-

-

... More
14.4.1 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba / rubbish to the nearest municipal dumping ground. For door / window / clerestory window

7.561

-

-

... More
14.5.1 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty : Float glass panes of thickness 4 mm

3.36

-

-

... More
22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

282

-

-

... More
od209996/2017-18 Supplying, providing and laying 4mm thick self smoothening epoxy flooring over the existing cement concrete floor. The features should be hardwearing, abrasion resistant, hygienic, easy to clean, non staining, non dusting. The products to be used will be procured from either of the following manufacturers/make FOSROC, ARDEX-ENDURA, RELIEANCE CHEMICALS, ADITYA BIRLA CHEMICAL, ALCHEMIC LTD, DR FIXIT OR STP. The bonding coat will be done from the solvent free epoxy primer and the porduct is to be self leveling epoxy screed. The top coat is to be self smoothening, abrasion resistant, hardwearing, chemical resistant and in the desired colour and shade. The flooring specification and should be classifed as per BS 6319, Any laitance, dust or other contamination of the existing floor are to be cleared by the contractor and any repairing, levelling etc. are alos to be done by the contractor before laying of epoxy. The primer is to be applied on the cleaned surface with the help of the rollers in the single coat and the fine sand will be spreaded to provide the mechanical key for the further coat (top coat). The 3 mm thick self leveling epoxy screed is to be applied as the body coat over the primed surface with the help of the spike rollers and the notch trowel, smoothern out the undulations upto 3mm and preparing a strong substrate to receive the epoxy self levelling top coat. The curing is to be done

564.035

-

-

... More
11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.

102.02

-

-

... More
8.13.1 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

450

-

-

... More
16.87.1 Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-charge. Area less than 0.50 sqm.

60

-

-

... More
11.36 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

756.865

-

-

... More
11.40 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.

74.25

-

-

... More
14.43 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

880.5

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer.

1385.077

-

-

... More
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @2.20 kg/10 sqm)

1385.077

-

-

... More
14.54.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade: One or more coats on old work

82.44

-

-

... More
21.17 Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge.(Only weight of grill to be measured for payment ).

108

-

-

... More
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in charge)0.50mm(+0.05%), total coated thickness with zing coating 120 grams. per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

840

-

-

... More
12.51.1 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm)

40

-

-

... More
12.52.1 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed

657.095

-

-

... More
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil

480

-

-

... More
16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge.

480

-

-

... More
11.20.2 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand). Medium shade pigment using 50% white cement 50 % Grey cement

10

-

-

... More
9.135.2 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.50 mm all complete. With 12 mm mild steel U beading

72

-

-

... More
Appendix B- CATTLE LAIRAGE CONSTRUCTION

-

-

-

... More
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil

11250

-

-

... More
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock

13.065

-

-

... More
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)

21.41

-

-

... More
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

45.684

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

11.421

-

-

... More
13.4.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)

19

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer

38

-

-

... More
13.44.1 Finishing walls with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm)

38

-

-

... More
10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

1015

-

-

... More
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes

876

-

-

... More
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in charge)0.50mm(+0.05%), total coated thickness with zing coating 120 grams. per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

218.4

-

-

... More
12.51.1 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm)

17

-

-

... More
11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc.

180

-

-

... More
13.18 Neat cement punning

180

-

-

... More
16.20 Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete block 45x45x60 cm of mix1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I stapes on wooden plugs or tied to 6 mm barnibs with G.I binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately):

81

-

-

... More
Appendix C- SHEEP LIRAGE CONSTRUCTION.

-

-

-

... More
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil

100

-

-

... More
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock

7.133

-

-

... More
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)

11.551

-

-

... More
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

40

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

4

-

-

... More
13.4.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)

23.201

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer

23.201

-

-

... More
13.44.1 Finishing walls with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm)

23.201

-

-

... More
10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

180

-

-

... More
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes

428.111

-

-

... More
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

72

-

-

... More
12.51.1 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm)

12

-

-

... More
11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

50

-

-

... More
13.18 Neat cement punning

50

-

-

... More
16.20 Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete block 45x45x60 cm of mix1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I stapes on wooden plugs or tied to 6 mm barnibs with G.I binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately):

51

-

-

... More
Appendix D- RENDERING PLANT Shed

-

-

-

... More
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil

300

-

-

... More
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock

30.93

-

-

... More
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)

34.532

-

-

... More
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

48

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

32.897

-

-

... More
5.6.1.1 Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

14.041

-

-

... More
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

0.897

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

2.801

-

-

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete

64.96

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more

493.26

-

-

... More
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes

2190.721

-

-

... More
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

216

-

-

... More
10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover

30

-

-

... More
11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

160

-

-

... More
13.18 Neat cement punning

160

-

-

... More
13.4.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)

230.801

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer

230.801

-

-

... More
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

230.85

-

-

... More
16.20 Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete block 45x45x60 cm of mix1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I stapes on wooden plugs or tied to 6 mm barnibs with G.I binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately):

136.5

-

-

... More
Appendix E- LABOUR QUARTERS Construction

-

-

-

... More
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil

225

-

-

... More
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock

22.264

-

-

... More
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)

34.682

-

-

... More
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

20.658

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

5.939

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

3.038

-

-

... More
4.3.1 Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns

2.51

-

-

... More
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

0.065

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

0.113

-

-

... More
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers

42.6

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more

332.75

-

-

... More
50.6.1.1 Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

36.39

-

-

... More
13.4.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)

386.312

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer

386.312

-

-

... More
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

386.312

-

-

... More
10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover

791.734

-

-

... More
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

216

-

-

... More
11.41.3 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800x 800 mm

58.591

-

-

... More
11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

10.08

-

-

... More
11.36 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer - in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

63.36

-

-

... More
50.9.2.2 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required sized with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer in-charge using Pincoda wood

32.07

-

-

... More
50.9.1.2 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) using good quality Pincoda wood

0.874

-

-

... More
12.45.1 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section

108

-

-

... More
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work

305.697

-

-

... More
Appendix F- EFFLUENT TREATMENT PLANT 50 KLD Construction

-

-

-

... More
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock

120.148

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

10.177

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

68.764

-

-

... More
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers

445.177

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more

7519.04

-

-

... More
13.4.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)

503.443

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer

186.846

-

-

... More
22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of : i) I course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) III course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/ sqm.

316.597

-

-

... More
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes

286.4

-

-

... More
13.50.3 Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

11.334

-

-

... More
13.52.2 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work

11.334

-

-

... More
Appendix G- UNDER GROUND WATER TANK 1 lakh LITRE CAPACITY.

-

-

-

... More
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

129.168

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

8.424

-

-

... More
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

11.233

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

12.32

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

6.318

-

-

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete

60

-

-

... More
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers

62.16

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more

4048

-

-

... More
13.4.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)

116.16

-

-

... More
22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of : i) I course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) III course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/ sqm.

110

-

-

... More
Appendix H- COMPOUND WALL WITH GATE

-

-

-

... More
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock

10.608

-

-

... More
50.6.1.1 Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

10.32

-

-

... More
50.6.1.5 Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

30.96

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

0.072

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

0.693

-

-

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete

3.61

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more

83.161

-

-

... More
13.4.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)

592.8

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer

592.8

-

-

... More
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

592.8

-

-

... More
10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover

753.061

-

-

... More
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work

12

-

-

... More
Appendix I- SEPTIC TANK AND SOAK PIT.

-

-

-

... More
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

24.036

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

1.808

-

-

... More
50.6.1.4 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

2.228

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

5.643

-

-

... More
5.9.3 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform

58.28

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more

564

-

-

... More
13.4.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)

33.201

-

-

... More
Appendix J- PLUMPING AND SANITARY FITTINGS (Slaughter house).

-

-

-

... More
50.18.8.3.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2

113

-

-

... More
50.18.8.6.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2

160

-

-

... More
50.18.8.9.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

107

-

-

... More
17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid

8

-

-

... More
17.9.1 Providing and fixing kitchen sink with C. I brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x250 mm

1

-

-

... More
17.25.1 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings: Flat back wash basin of size 630x450 mm

14

-

-

... More
17.28.1.2 Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete. Semi rigid pipe 40 mm dia

10

-

-

... More
18.15.2 Providing and fixing brass bib cock of approved quality: 20 mm nominal bore

22

-

-

... More
Appendix K- LANDSCAPING WORK.

-

-

-

... More
16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge.

958.051

-

-

... More
30.2.33 Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler

356.5

-

-

... More
Appendix L- ELECTRICAL WORK WITH TRANSFORMER

1

-

-

... More
Appendix M- GST 12% OF CIVIL COST (RS. 1,95,51,428/-)

1

-

-

... More
Electrification

-

-

-

... More
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B

140

-

-

... More
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

60

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

600

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

90

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

190

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

450

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

50

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

200

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

250

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

50

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

2

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

3

-

-

... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

3

-

-

... More
90.10.1.2 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface

3

-

-

... More
90.10.1.3 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface

2

-

-

... More
90.10.1.6 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface

1

-

-

... More
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

2

-

-

... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

2

-

-

... More
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

1

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

11

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

15

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

2

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

2

-

-

... More
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

12

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.

168

-

-

... More
od163485/2018_2019 : Supply and fixing of poly carbonate cable junction box having size 139x119x70 mm grey/black with terminal, for Cu /Al conductors with knockouts types suitable for 4 to 16 sq.mm range Cable Junction Boxes for outside applications, having IP 66 degree of protection , water- proof, UV-resistant and including suitable din rail or base etc for fixing MCB/isolator/Contractor etc if required , fixed on existing pole or pillar with necessary specials and accessories as required ( Make HENSEL/Equivalent )

10

-

-

... More
od163499/2018_2019 : Supply and fixing of 300 x 450x170 mm size Opaque /transparent type with knockouts types sip IP 67 rated Boxes with including suitable din rail or base etc suitable for fixing MCB/ isolator/Contractor etc and water proof cable gland etc if required , fixed on existing pole or pillar with necessary specials and accessories as required ( Make HENSEL/Equivalent )

6

-

-

... More
od163501/2018_2019 : Supply and fixing of 300x150x170 mm size Opaque /Transparent type IP 66 type water-proof and including suitable din rail or base etc for fixing SDU/MCB/isolator/Contractor etc if required , fixed on wall with necessary specials and accessories as required ( Make HENSEL/Equivalent

36

-

-

... More
od163511/2018_2019 : Supplying and fixing 16 /20 amp, 230 V, 50 Hz male type 3 pin (2P+E) plug socket outlet suitable for surface mounting, water tight socket ( IP 67,) with suitable accessories and giving connections etc. as required (Hensel or its equivalent make)

14

-

-

... More
od163513/2018_2019 : Supplying and fixing surface mounting type 16/20 A , 230 V , 50 HZ water tight female 3 pin ( 2P+E) socket IP 67 protection , including fixing the socket on wall using suitable accessories and giving connection as required (Hensel or equivalent make) .

14

-

-

... More
Fittings

-

-

-

... More
1.36 : Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit,aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and painting etc. as required.

24

-

-

... More
1.40 : Providing and fixing plain 16/0.20 mm (0.50 sqmm) twin circular flexible FRLS PVC insulated, PVC sheathes copper cable direct on the wall with PVC clips etc as required.

66

-

-

... More
1.51 : Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes

12

-

-

... More
1.48 : Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

180

-

-

... More
1.43 : Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

16

-

-

... More
od163362/2018_2019 : Supply, conveyance, installation, testing and commissioning of 35S LED well glass light fittings of Philips (BY200PLED 35S CW PSU S2PC) or its equivalent having lumen output not less than 3500 lumen as required with all accessories etc. and FIXED on the exiting rod /pipe (separate measurement and including fabrication nut and bolt etc with using standard flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. Philips / its equivalent.

44

-

-

... More
od205695/2018_2019 : Supply Conveyance, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories and fluorescent lamps etc. directly to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.for Round LED down light fitting out put not less than 1200lumen efficiency not less than 105lu/watt steel/aluminum enclosure complete

14

-

-

... More
od205697/2018_2019 : Supply conveyance, installation, testing and commissioning of all out door light fittings complete with all accessories in the existing GI pipe and giving connections as required. 40W LED fitting IP66 with lumen out put not less than 105 lumen/watt with LM79 /80 tests compliance from third party

4

-

-

... More
od165826/2018_2019 : Supply and fixing of gate lamp aluminium and synthetic body integrated type 8 W LED lamp with RoHS complied , duly wired up for use on 230 V AC supply and giving connection etc.including making good the damages, colour washing etc as required. ( Model Robbin- 15472 Make -Philips or Equivalent)

2

-

-

... More
90.3.20.3 : Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture

63

-

-

... More
90.3.24.3 : Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture

6

-

-

... More
90.3.20.4 : Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture

9

-

-

... More
90.3.24.4 : Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 2X20W LED Lamp with box type fixture

15

-

-

... More
90.3.7 : Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.

18

-

-

... More
90.3.23.4 : Supply & installation of fittings suspended on steel chain Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet .5mm thick with all accessories and lamps etc. suspended from ceiling using 2 nos steel chain (16 SWG or nearest available size) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200mm 2X20W LED Lamp with box type fixture

6

-

-

... More
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

3

-

-

... More
90.4.2 : Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.

15

-

-

... More
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C

18

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

18

-

-

... More
90.3.18.3 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat

6

-

-

... More
od201690/2018_2019 : Supply conveyance, installation, testing and commissioning of all out door light fittings complete with all accessories in the existing GI pipe and giving connections as required. 70W LED fitting IP66 with lumen out put not less than 105 lumen/watt with LM79 /80 tests compliance from third party

20

-

-

... More
od205699/2018_2019 : Supply and errection of octoganal galvanized pole 7 mtr height complete with Double arm bracket 500mm projection, 200x200x12mm size base plate , 4Nos 20mm dia 600mm length foundation bolts and nuts space for mounting control switch box with inspection type door at a height of 550mm from the road level including fixing smart pack jungtion box with 6 A MCB and sted terminal (for mounting inside base compartment of pole) ( Bajaj BOP 7030/ or equlent make) etc as required on existing foundation

4

-

-

... More
od205701/2018_2019 : Supply and errection of octoganal galvanized pole 7 mtr height complete with Single arm bracket 500mm projection, 200x200x12mm size base plate , 4Nos 20mm dia 600mm length foundation bolts and nuts space for mounting control switch box with inspection type door at a height of 550mm from the road level including fixing smart pack jungtion box with 6 A MCB and sted terminal (for mounting inside base compartment of pole) ( Bajaj BOP 7030/ or equlent make) etc as required on existing foundation

4

-

-

... More
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm

100

-

-

... More
90.4.9 : Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.

12

-

-

... More
od157527/2018_2019 : Supply, Conveyance,Testing and Commissioning of 380 mm sweep, 1400 rpm working on 230 V A/C Heavy Duty Exhaust fan in the existing opening using suitable size anchor bolt / Screws etc and giving connection as reqquired.

10

-

-

... More
od205689/2018_2019 : Supply, conveyance, installation , testing and commissioning of exhaust fans of size 300mm light duty 1300rpm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.

2

-

-

... More
od205691/2018_2019 : Supplying and fixing cast aluminium bulk head fitting with mesh guard with 7W LED bulb and giving connection etc. as required.

6

-

-

... More
od205693/2018_2019 : Supplying and fixing PVC batten/ angle holder including 3 W LED Bulb and plastic shade and giving connection etc. as required.

42

-

-

... More
od163384/2018_2019 : Supply, Conveyance,Testing and Commissioning of 400 mm sweep, 60 watt 1440 rpm 3 Nos metal blade with mesh guard working on 230 V A/C wall mounting fan in the existing wall using suitable size anchor bolt / Screws etc and giving connection as required (Almonard/Crompton/or its equivalent)

5

-

-

... More
DB , MCB, MPCB, ACB and MCCB

-

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

5

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

2

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
2.23.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 8 way, Double door SPN MCBDB

1

-

-

... More
2.23.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 6 way, Double door SPN MCBDB

4

-

-

... More
2.23.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 10 way, Double door SPN MCBDB

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

86

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

8

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

2

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

20

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

2

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

2

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

5

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

2

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

5

-

-

... More
od159581/2018_2019 : Supply and fixing 3 phase 3 pole 4 A , Rotary handle type MPCB rating and breaking capacity 100 KA Icu and including short circuit and overload protection (4-6.3 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or Equivalent make)

22

-

-

... More
od157529/2018_2019 : Supply and fixing 3 phase 3 pole 19 A , Rotary handle type MPCB rating and breaking capacity 50 KA (Icu)and including short circuit and overload protection (19-25 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)

2

-

-

... More
od157531/2018_2019 : Supply and fixing 3 phase 3 pole 11 A , Rotary handle type MPCB rating and breaking capacity 100 KA (Icu)and including short circuit and overload protection (11-16 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)

1

-

-

... More
od157533/2018_2019 : Supply and fixing 3 phase 3 pole 9 A , Rotary handle type MPCB rating and breaking capacity 100 KA (Icu)and including short circuit and overload protection (9-13 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)

2

-

-

... More
od157535/2018_2019 : Supply and fixing 3 phase 3 pole 6 A , Rotary handle type MPCB rating and breaking capacity 100 KA (Icu)and including short circuit and overload protection (6.3-10 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)

9

-

-

... More
od159577/2018_2019 : Supply and fixing 3 phase 3 pole 45 A , Rotary handle type MPCB rating and breaking capacity 50 KA (Icu)and including short circuit and overload protection (45-63 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)

1

-

-

... More
od159579/2018_2019 : Supply and fixing 3 phase 3 pole 24 A , Rotary handle type MPCB rating and breaking capacity 50 KA (Icu)and including short circuit and overload protection (24-32 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)

3

-

-

... More
od164239/2018_2019 : MPCB Accessories Supply and fixing rotary handle, External type in the existing MPCB of rating up to 63 A

40

-

-

... More
90.14.10.3 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

6

-

-

... More
90.14.10.14 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

2

-

-

... More
od205121/2018_2019 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 160A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB withthermal magnetic release with overload setting of 80 - 100% having adjustable OL & SC

4

-

-

... More
od205703/2018_2019 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB withthermal magnetic release with overload setting of 80 - 100% having adjustable OL & SC

4

-

-

... More
od205705/2018_2019 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 200A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB withthermal magnetic release with overload setting of 80 - 100% having adjustable OL & SC

6

-

-

... More
od170014/2018_2019 : Providing and fixing of 125 Amp,, 4 pole Switch dis connector fixed type MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. ( L& T or its equivalent make)

1

-

-

... More
90.14.11.13 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

26

-

-

... More
90.14.11.17 : MCCB AccessoriesSupply and fixing kastel interlock kit up to 250A.

1

-

-

... More
2.1.1 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N

37

-

-

... More
2.1.2 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N

4

-

-

... More
2.1.3 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N

2

-

-

... More
od165284/2018_2019 : Providing and fixing 63 A TP - N Switch dis connector unit inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required.(L&T or its equivalent make)

4

-

-

... More
od165286/2018_2019 : Providing and fixing 100 Amp TP -N Switch dis connector unit inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required. L&T or equivalent make

1

-

-

... More
90.14.10.22 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 70 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

3

-

-

... More
90.14.11.15 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A

3

-

-

... More
90.14.11.18 : MCCB AccessoriesSupply and fixing kastel interlock kit 315 to 630A.

2

-

-

-

-

-

... More
od157537/2018_2019 : Supply and fixing of 8 stage 440 V 5A/1A, Intelligent Power Factor Controllers (APFC unit fixed in panel board with all required accessories and giving connection as required.(L&T or its equivalent make)

1

-

-

... More
od206344/2018_2019 : Providing and fixing following capacitor duty contactor 20 KVAR existing panel and giving connection complete

2

-

-

... More
od206332/2018_2019 : Providing and fixing following capacitor duty contactor 7.5 to 10 KVAR existing panel and giving connection complete

3

-

-

... More
od206334/2018_2019 : Providing and fixing following capacitor duty contactor 4 to7 KVAR existing panel and giving connection complete

2

-

-

... More
90.14.24.31 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.

2

-

-

... More
90.14.24.34 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.

3

-

-

... More
90.14.24.37 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.

2

-

-

... More
od172029/2018_2019 : Supply, conveyance, installation, testing and commissioning of the Panel temperature controlled fan 100x100mm size 24V DC /240V AC with thermostat and giving connection as required.

2

-

-

... More
Transformer and DG

-

-

-

... More
od159830/2018_2019 : 1No,Supply, Conveyance, Installation, Testing and Commissioning of 1 No. Out door type 630A, 11KV,21 KA, Triple pole, 50 Hz. 1 Way Motorised SF6 Gas Insulated double side Extensible type RMU Breaker and Vacuum Circuit Breaker with following facilities a1 No.-Air Circulated cable Box with Gland Plate suitable for a bottom entry single run 3 core cable up to 300 sq.mm size. c1 Set-. Cable bushing/box mounted type Over Current protection Transformer having ratio 100/50/1A- 5P10,2.5VA d1 set. Over current and Earth Fault Relay with display and auxilary power supply etc. e"1 No. -Mimic diagram on front panel with complete status indicators like ON-OFF-EARTH etc " f"1 set. - Capacitive voltage LED display type indicators, earth fault indicator etc " g1-Set- of positive standard mechanical interlocks and padlock to avoid unsafe operation. h1 set- SF6 low pressure switch / pressure gauge. i1 No- local PULL To TRIP mechanism for Emergency Trip j1 set- Right angle Boots k1 set - Suitable size Battery set and Battery charger etc l1 set -Actutator Kit for motorised operation. The enclusure of the unit shall made 2 mm CRCA sheet with powder coated and comply to IP 54 standards and minimum 95 KV surge protection . The unit shall be Fully SCADA compatible with remote switchingng. The enclosure shall be earthed and provided positive safety interlocks on all switch / selector positions ensure operator safety & prevent incorrect operation.

1

-

-

... More
od171713/2018_2019 : Installation & Commissining of indoor type USS, 11KV/433V,50Hz,315 KVA,3 Phase, Delta- Star,Vector DYN-11 Laser Scribed transformer with off circuit tapping from + 5% to -10% in step of 2.5%,changeable off circuit by tap links provided, with WTI & LV terminals suitable for 2 runs of XLPE cable and HV terminals connected to 11KV, 26.3KA,630A Load break switch, with incoming suitable for XLPE cable, with HT HRC fuses, 6Nos CTs, 2No PT, Ammeter. Voltmeter, Earth fault Relay, Over current relay, Master trip,4 window annunciation with hooter. copper bus bar, provision for fixing for TOD Meter and out put connected to 11KV seal off bushings to the transformer. The Transformer shall conform to IS 11171/1985 re-affirmed in 1991. The maximum alowable loss at full load is 2.07% and half load is 1.61%. H.T. PortionHT portion shall consists of:1No. 630A, 26.30 kA load break switch suitable for 3 phase, 3wire, 50 Hz system with HT HRC fuses of appropriate rating with earth switch inter lock with main switch and mechanical ON/OFF indication Shunt trip coil for the remote operation of the Load Break Switch(make T.O.D Metering facilities. For Clint3 Nos 30/5A (or suggested by KSEB)15 VA 0.2s Class accuracy cast resin C.T.1 No 3 Phase 3 limb 11 KV/110 V, 10 VA 0.2 accuracy class cast resin PT with protective fuses.Provision for 1 No. TOD Meter(rate not included).The TOD meter compartment and CT / PT

1

-

-

... More
od205105/2018_2019 : Installation, Testing & Commissioning of 250 KVA Diesel Generator set with integral acoustic enclosure as per CPCB norms with srandared acessories as per technical details given below. 1. Engine : a) Make of Engine - Kirloskar//Cummins/Leyland/Volvo b) Type of Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Water cooled with radiator. e) Design - Suitable for generating set operation 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Fuel filter g) Lubricating oil filter h) Exhaust silencer i) Exhaust Muffler j) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make - Kirloskar/KEL//Stanford/LS b) Type - Self exited and self regulated. c) Capacity - 40 KVA/32 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, e) Frequency - 50 Hz f) Insulation - Class F/H The Alternator should confirm to IS 4722. Operation and service manual, spares and tools shall be provided. 7. Fuel Tank Suitable size built in type integrated with the acoustic

1

-

-

... More
od205109/2018_2019 : Installation, testing & commissioning of 62.5 KVA Diesel Generator set with integral acoustic enclosure as per CPCB norms with srandared acessories as per technical details given below. 1. Engine : a) Make of Engine - Kirloskar//Cummins/Leyland b) Type of Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Water cooled with radiator. e) Design - Suitable for generating set operation 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Fuel filter g) Lubricating oil filter h) Exhaust silencer i) Exhaust Muffler j) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make - Kirloskar/KEL//Stanford/LS b) Type - Self exited and self regulated. c) Capacity - 40 KVA/32 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, e) Frequency - 50 Hz f) Insulation - Class F/H The Alternator should confirm to IS 4722. Operation and service manual, spares and tools shall be provided. 7. Fuel Tank Suitable size built in type integrated with the acoustic

1

-

-

... More
od170658/2018_2019 : Supplying and fixing of exhaust pipe of 150 mm sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc . adequately supported on rigid supports duly painted with heat resistant paint as per specification and as required complete in all respect.

7

-

-

... More
od170660/2018_2019 : Supplying and fixing of exhaust pipe of 80 mm sizes of MS 'C' class along with necessary clamps, vibration ,isolators and fittings such as bends, tees etc . adequately supported on rigid supports duly painted with heat resistant paint as per specification and as required complete in all respect. -

7

-

-

... More
od170662/2018_2019 : Supplying, and fixing, 65 mm thick resin bonded fiber glass wool /rock wool having density of 48kg/m3 fixed on DG Exhaust Muffler of DG set for the thermal insulation and each layer covered by a layer of chicken mesh and finally applying 0.63 mm aluminium sheet cladding complete as per specifications and as required .

5

-

-

... More
od170664/2018_2019 : EXHAUST PIPE ( 150 MM )CLADDING: Supplying, and fixing, 65 mm thick resin bonded fiber glass wool having density of 48kg/m3 fixed on 150 mm pipe section for the thermal insulation and totally covered with a layer of chicken mesh and finally applying 0.63 mm aluminium sheet cladding complete as per specifications and as required on the existing MS pipe of DG exhaust.

7

-

-

... More
od170668/2018_2019 : EXHAUST PIPE ( 80 MM )CLADDING: Supplying, and fixing, 65 mm thick resin bonded fiber glass wool having density of 48kg/m3 fixed on 80 mm pipe section for the thermal insulation and totally covered with a layer of chicken mesh and finally applying 0.63 mm aluminium sheet cladding complete as per specifications and as required on the existing MS pipe of DG exhaust.

7

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

2

-

-

... More
od171346/2018_2019 : Charges for conducting load test of 62.5 KVA DG set at standardized Factory bed as per standard norms and condition. ie in various steps load up to full load for 3 hours & 10% over load for 20 minutes and the rate includes hire and rent of test bed equipment's, labour charges ,loading and unloading and fuel etc.The test certificate should be given the client in standard format.

1

-

-

... More
od171348/2018_2019 : Charges for conducting load test of 250 KVA DG set at standardized Factory bed as per standard norms and condition. ie in various steps load up to full load for 3 hours & 10% over load for 20 minutes and the rate includes hire and rent of test bed equipment's, labour charges ,loading and unloading and fuel etc.The test certificate should be given the client in standard format.

1

-

-

... More
Panel Fabrication

-

-

-

... More
90.14.1.1 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut- outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)

32

-

-

... More
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut- outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)

60

-

-

... More
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

1

-

-

... More
90.14.2.2 : Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

3

-

-

... More
90.14.3.4 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 40 x 3mm heavy duty flat neoprene gasket in the panel board

150

-

-

... More
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

34

-

-

... More
90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board

5

-

-

... More
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

30000

-

-

... More
90.14.7 : Supply and providing copper earth bus in the panel board

2750

-

-

... More
od205709/2018_2019 : Copying charges of Electrical/fire Drawing per A3 sheet additional copies

90

-

-

... More
od205711/2018_2019 : Charges for preparation of Electrical/fire Drawing per A3 sheet first copy

15

-

-

... More
CABLE /TRAY/PIPE/GLAND

-

-

-

... More
90.12.1.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 50 sq mm

30

-

-

... More
90.12.1.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 70 sq mm

50

-

-

... More
90.12.1.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm

20

-

-

... More
90.12.1.1 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sq mm

15

-

-

... More
90.12.1.2 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm

30

-

-

... More
90.12.1.12 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm

50

-

-

... More
90.12.1.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm

200

-

-

... More
90.12.1.39 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq mm

50

-

-

... More
90.12.5.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm

20

-

-

... More
90.12.5.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 70 sq mm

20

-

-

... More
90.12.5.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm

5

-

-

... More
90.12.7.1 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp

10

-

-

... More
90.12.7.2 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp

100

-

-

... More
90.12.7.16 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 25 sq mm with factory made clamp

60

-

-

... More
90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm

20

-

-

... More
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

35

-

-

... More
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp

40

-

-

... More
90.12.7.12 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp

1100

-

-

... More
90.12.7.13 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp

150

-

-

... More
90.12.7.15 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 16 sq mm with factory made clamp

60

-

-

... More
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp

20

-

-

... More
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

20

-

-

... More
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

25

-

-

... More
90.12.7.36 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm

60

-

-

... More
90.12.41.35 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp

50

-

-

... More
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

60

-

-

... More
90.12.41.7 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp

20

-

-

... More
90.12.41.32 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp

70

-

-

... More
od201692/2018_2019 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 11 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments

20

-

-

... More
od201694/2018_2019 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in the existing masonry open duct as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments

10

-

-

... More
od201696/2018_2019 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 11KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments

20

-

-

... More
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

12

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

90

-

-

... More
9.1.9 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 25 sq. mm (25mm)

2

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

12

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

4

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

6

-

-

... More
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

4

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

4

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

4

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

4

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

1

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

-

-

... More
14.15.1 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)

65

-

-

... More
14.15.2 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)

10

-

-

... More
14.15.3 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)

10

-

-

... More
4.1.1 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
4.1.2 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

125

-

-

... More
4.1.4 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
4.1.6 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness

15

-

-

... More
4.1.7 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

40

-

-

... More
Contator /Meter/Indications/Relay/CT

-

-

-

... More
od171060/2018_2019 : Supply and fixing of 9 A, 3 pole POWER CONTACTOR (For 5.5 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INCs etc as required.

21

-

-

... More
od171076/2018_2019 : Supply and fixing of 25 A, 3 pole POWER CONTACTOR (For 15 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.

3

-

-

... More
od171078/2018_2019 : Supply and fixing of 12 A, 3 pole POWER CONTACTOR (For 7.5 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.

13

-

-

... More
od171080/2018_2019 : Supply and fixing of 40 A, 3 pole POWER CONTACTOR (For 25 HP motor), AC3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.

6

-

-

... More
od171082/2018_2019 : Supply and fixing of 18 A, 3 pole POWER CONT ACTOR (For 10 HP motor), AC3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.

6

-

-

... More
od171136/2018_2019 : Supply and fixing of 65 A, 3 pole POWER CONTACTOR (For 50 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.

3

-

-

... More
od160413/2018_2019 : Supply and fixing 240/360/415V ON/Off delay Electronic timer suitable for motor starter ( L& T or equivalent make)

6

-

-

... More
od159917/2018_2019 : Supply and fixing of Multi function meter to read: V, A, F, 3 phase accuracy class 1 LED

5

-

-

... More
od164043/2018_2019 : Supply and fixing of Three Phase Ammeter accuracy class 1 and giving connection.

6

-

-

... More
od165387/2018_2019 : Supply and fixing of Three Phase Voltmeter accuracy class 1 and giving connection.

1

-

-

... More
od171142/2018_2019 : Supply & fixing HT TOD meter,3 phase, 4 wire, 110V(L-L), for 1A / 5A CT with out CT (Accuracy class 0.2s)

1

-

-

... More
od171150/2018_2019 : Supply and Fixing of POWER CONTACTOR AC-1 rating , 160A , 4 Pole, 415 A, 50 HZ with 2No, NO/NC auxiliary contactors, mechanical interlock etc and fixing in the exising cubicle with all accessories and giving connection as required(L&T or its equivalent).

2

-

-

... More
od171152/2018_2019 : Supply and fixing of Single phase preventer relay and giving connection etc (L& T or ts Equivalent make)

2

-

-

... More
od160409/2018_2019 : Supply and Fixing of Flush head Push Button with 1 NO Block

49

-

-

... More
od160411/2018_2019 : Supply and fixing of Flush head Push Button with 1 NC Block

42

-

-

... More
od165312/2018_2019 : Supply and Fixing of Rotary switch 1P 2 way 6A Auto /Manul and giving connection etc as required.

2

-

-

... More
od165314/2018_2019 : Supply and fixing of SP MCB below 1 to 4A 10KA 'C' Curve and giving connection as required.

24

-

-

... More
od159921/2018_2019 : Supply and Fixing of Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia

22

-

-

... More
od159923/2018_2019 : Supply and Fixing of Blue colour LED indicator, AC/DC, 22.5 mm cut out dia

22

-

-

... More
od166558/2018_2019 : Supply and Fixing of Illuminated Flush head Actuator - Red with legend 'OFF', (Contact - 1 NC)

51

-

-

... More
od166560/2018_2019 : Supply and Fixing of Illuminated Flush head Actuator - Green with legend 'ON', (Contact - 1 NO)

51

-

-

... More
od172374/2018_2019 : Supply and fixing following rating Surge Protection Devices (3P+N) ,Conforms to IEC 61643-11, Type 1+2(Protection against direct and indirect lightning surges) , Maximum Discharge Current - Imax up to 100 kA in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (L&T or Equivalent Make)

1

-

-

... More
od165268/2018_2019 : Supply and Fixing of PLA Relay 24V 5A 8/11 pin with base and Giving connection etc as required

10

-

-

... More
od171364/2018_2019 : Supply and installation, testing and commissioning of AMF Relay and giving connections as required

2

-

-

... More
od159925/2018_2019 : Supply and Fixing of 100/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT

9

-

-

... More
od167992/2018_2019 : Supply and Fixing of 500/5 A, 15 VA, accuracy class 1, Resin Cast Metering CT

5

-

-

... More
od164265/2018_2019 : Supply and Fixing of 400/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT

6

-

-

... More
od164261/2018_2019 : Supply and Fixing of 200/5 A, 10 VA, accuracy class 1, Resin Cast Metering CT

3

-

-

... More
od167996/2018_2019 : Supply and fixing of 70/5 A, 5 VA, accuracy class 10P 5, Protection CT (Tape wound)

1

-

-

... More
od167998/2018_2019 : Supply and Fixing of 100/5 A, 10 VA, accuracy class 10P 5, Protection CT (Tape wound)

1

-

-

... More
od166336/2018_2019 : EMERGENCY PUSH BUTTON:- Supply Installation, Testing and Commissioning of Manual Call Points of break glass type with hammer and chainM if required.

1

-

-

... More
od166338/2018_2019 : Supply and Fixing of Mushroom headed Spring return/pull type ON -OFF switch 16A and giving connection as required

2

-

-

... More
od166340/2018_2019 : Supply and Fixing of Bakelite Fuse Base 20A with HRC Fuse Link 2A and giving connection as required

50

-

-

... More
od166692/2018_2019 : Supply & fixing the 32A, 2 Way neutral links mounted on DMC/SMC base

8

-

-

... More
od166580/2018_2019 : Supply and fixing of 32 A HRC Fuse base with HRC link and 32 A 2 Way neutral link in the existing single phase metering cubicle etc as required

1

-

-

... More
od164851/2018_2019 : Supply and Fixing of Battery Charging selector switch (Rotary Switch) and giving connection as required

2

-

-

... More
od166342/2018_2019 : Supply and Fixing of DC Ammeter Digital CL 0.5 0 to 30A and giving connection as required

2

-

-

... More
od159941/2018_2019 : Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

90

-

-

... More
od159943/2018_2019 : Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 1.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

140

-

-

... More
od159945/2018_2019 : Supply, laying and clamping of 1 no. 2.5 sqmm 8 core PVC/ XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE with the cables, spacing of clamps with factory made clamp not exceeding 60cms, making good the damages , colour washing etc. as required.

25

-

-

... More
od159947/2018_2019 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed 2.5 sqmm 2 core PVC / XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE , spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

50

-

-

... More
od164163/2018_2019 : Supply and wiring with single core copper conductor cables 4 sq mm single run with required sockets.650/1100 V grade PVC insulated stranded conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size sockets at the termination points, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

49

-

-

... More
od165274/2018_2019 : Supply and wiring with single core copper conductor cables 6 sq mm single run with required sockets.650/1100 V grade PVC insulated stranded conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size sockets at the termination points, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

12

-

-

... More
od167422/2018_2019 : Supply and wiring copper conductor cables 16 sq mm single run with required sockets.650/1100 V grade PVC insulated stranded conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size sockets at the termination points, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

10

-

-

... More
od165276/2018_2019 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor control cable of 650V grade as required. 2 X 1.5/2.5sq. mm (16/19mm)

8

-

-

... More
od165278/2018_2019 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor control cable of 650V grade as required. 8 X 1.5/2.5sq. mm (22/25mm)

6

-

-

... More
od164213/2018_2019 : Supply and Fixing of Auto - Manual, 40 x 25 mm with 15 m hole aluminium anodised legend plates

4

-

-

... More
od164215/2018_2019 : Supply and Fixing of Earth, 40 x 20 mm with 8 mm hole aluminium anodised legend plates

7

-

-

... More
od164217/2018_2019 : Supply and Fixing of Cable alley, 100 x 40 mm aluminium anodised legend plates.

14

-

-

... More
od164219/2018_2019 : Supply and fixing of Bus bar chamber, 100 x 40 mm aluminium anodised legend plates

9

-

-

... More
od164221/2018_2019 : Supply and Fixing of Danger 415 V, 150 x 100 mm aluminium anodised legend plates

6

-

-

... More
od164223/2018_2019 : Supply and Fixing of Danger 415 V, 200 x 150 mm aluminium anodised legend plates

1

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
EARTHING

-

-

-

... More
od159836/2018_2019 : Supply and providing plate earthing with 1200x1200x12 mm GI/CI earth plate as per IS 3043, 50mm GI watering pipe, GI funnel with weld mesh, 25 x 3mm GI clamps, charcoal etc., including providing brick work masonry enclosure at the top (450 x 450 x 450 mm inside) and CI/MS cover plate hinged to FRL Same with Locking arrangement but excluding earth continuity conductor, test joint etc

6

-

-

... More
od171190/2018_2019 : Supply and clamping the 32 x 3 mm sizes of COPPER STRIP tinned at the points of contacts and fixed on surface of wall/ parapet/ existing cable tray using factory made clamp , not exceeding 1m, making good the damages, colour washing etc. as required

150

-

-

... More
od171192/2018_2019 : Supply and clamping the 25 x 3 mm sizes of COPPER STRIP tinned at the points of contacts and fixed on surface of wall/ parapet/ existing cable tray using factory made clamp , not exceeding 1m, making good the damages, colour washing etc. as required

430

-

-

... More
od171296/2018_2019 : Providing and fixing 25 mm X 3 mm size COPPER STRIP tinned at the points of contacts , laying in the existing trench or along with the cable including connection/ Jointing with brass nut, bolt, spring, washer etc . as required.

500

-

-

... More
od171298/2018_2019 : Providing and fixing 32mm X 3 mm size COPPER STRIP tinned at the points of contacts , laying in the existing trench or along with the cable including connection/ Jointing with brass nut, bolt, spring, washer etc . as required.

100

-

-

... More
od164233/2018_2019 : supply of superior quality copper earth socket for 3.14mm (10SWG) of earth conductor including crimping etc. as required.

80

-

-

... More
od167220/2018_2019 : 12SWG Bare copper conductor

130

-

-

... More
od167222/2018_2019 : 14SWG bare copper conductor

50

-

-

... More
od164235/2018_2019 : 10SWG bare copper condutor

680

-

-

... More
od166272/2018_2019 : Supply and Laying of 8 SWG bare copper conductor

100

-

-

... More
od164237/2018_2019 : Supply and Laying of 6 SWG Bare copper conductor and giving connection as required.

10

-

-

... More
od167270/2018_2019 : Supply and Laying of 4SWG Bare copper conductor

10

-

-

... More
od167280/2018_2019 : supply of superior quality copper earth socket for 2.00mm (14SWG) of earth conductor including crimping etc. as required.

350

-

-

... More
od167282/2018_2019 : supply of superior quality copper earth socket for 2.65mm (12SWG) of earth conductor including crimping etc. as required.

6

-

-

... More
od167284/2018_2019 : supply of superior quality copper earth socket for 3.14mm (10SWG) of earth conductor including crimping etc. as required.

173

-

-

... More
od167286/2018_2019 : supply of superior quality copper earth socket for 4mm (8SWG) of earth conductor including crimping etc. as required.

6

-

-

... More
od167288/2018_2019 : supply of superior quality copper earth socket for 4.75mm (6SWG) of earth conductor including crimping etc. as required.

6

-

-

... More
od167290/2018_2019 : supply of superior quality copper earth socket for 6mm ( 4SWG) of earth conductor including crimping etc. as required.

4

-

-

... More
od167393/2018_2019 : Supply and providing 25x3mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required

200

-

-

... More
od167416/2018_2019 : Supply and providing 25x6mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required

100

-

-

... More
Miscellaneous /Civil

-

-

-

... More
od160010/2018_2019 : Supply and providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength including fixing with suitable synthetic adhesive,

2.5

-

-

... More
od172023/2018_2019 : Supply and providing 6mm MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for the cable trench covering.

300

-

-

... More
od160012/2018_2019 : Supply and providing 2mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength including painting in ground with suitable synthetic adhesive.

12

-

-

... More
od172035/2018_2019 : Fabrication, supply, conveyance and fixing frame work made out of suitable size angle iron/ flat cut and welded to shape of suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gears/Cabel/machines for support , fixed to wall/floor using suitable size anchor bolts etc grouted to wall, making good the damages, colour washing etc as required

400

-

-

... More
od165690/2018_2019 : Supply of Electrical safety hand Glows 2.9mm minimum thickness,withstanding 26 KV protection made by Natural Latex, off white colour ( Certification shall be attached) .

1

-

-

... More
14.1 : Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.

25

-

-

... More
14.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.

1.2

-

-

... More
14.10 : Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).

1.8

-

-

... More
od171991/2018_2019 : STEEL REINFORCEMENT- Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.

50

-

-

... More
14.11 : Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.

2

-

-

... More
14.12 : Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.

15

-

-

... More
od160016/2018_2019 : Supply and providing 6 Kg. ABC Fire Extinguisher with hose and clamps including fixing it to wall as required.

13

-

-

... More
od160018/2018_2019 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. as per IS 2546

4

-

-

... More
od160020/2018_2019 : Painting letters or figures of the 2.50 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, panel board etc as required

800

-

-

... More
ETP MACHINERY

-

-

-

... More
Coarse Bar Screen make GIES

2

-

-

... More
Raw Effluent Transfer Pump make LUBI

2

-

-

... More
Coarse Bubble Grid make GIES

10

-

-

... More
pH Booster Dosing System Dose make Chemi

1

-

-

... More
Coagulant Dosing System Dose make Chemi

1

-

-

... More
Flocculent Dosing System Dose make Chemi

1

-

-

... More
Sludge Transfer Pump make Kirloskar

1

-

-

... More
Aeration Tank Feed Pump make Kirloskar

2

-

-

... More
Process Air Blower make Blowacc

2

-

-

... More
Induction motor Kirloskar make

2

-

-

... More
Fine Bubble Diffusers make Scogen

24

-

-

... More
Tube Settler Make CFM

4.5

-

-

... More
Sludge Recirculation Pump make Kirloskar

1

-

-

... More
Hypo Dosing System Dose make Chemi

1

-

-

... More
Filter Feed Pump Kirloskar make

2

-

-

... More
Pressure Sand Filter GIES make

1

-

-

... More
Activated Carbon Filter GIES make

1

-

-

... More
Total Electrical cost by including the following MCC panel ( Components are of L & T make), No. of TOD Meter, Electrical cable

1

-

-

... More
Others by including the following, Piping for Aeration ( MOC – GI of reputed make), Piping for transfer of waste water ( MOC- Sch 40), Ball Valves & Others, Chemicals for initial start up.

1

-

-

... More
INSTRUMENTATION No. of Level Switch – 6 Nos, Sinicon make Pressure Gauge – 02 Nos, H Guru make Mechanical Flow Meter – 01 N

1

-

-

... More
CCTV FACILITY

-

-

-

... More
16 channel NVR with 2 Sata - - 200Mbps -Up to 8MP Resolution for Preview and Playback

1

-

-

... More
2Megapixel Bullet IP Camera(30mtr)- Res:25fps@2MP - Lens:3.6mm

8

-

-

... More
2Megapixel Domet IP Camera(30mtr)- Res:25fps@2MP - Lens: 3.6mm

8

-

-

... More
24-Port unmanaged 10/100/1000 Base- T PoE Ethernet Switch (Net gear/HP)

1

-

-

... More
19" 10U Metal Rack Including Full loaded Patch Panel, Cable Manager,Patch Code, Fan etc and Installation Charge

1

-

-

... More
Dlink Connector

40

-

-

... More
Harddisk 4 Tb WD

2

-

-

... More
Fixing, testing Charge per Camera

16

-

-

... More
Cable cat6 D-Link including Materials and laying Charge

600

-

-

... More
FIRE FIGHTING EQUIPMENTS

-

-

-

... More
ABC (Dry Chemical Powder) – Stored pressure – Fire Extinguisher – 4 Kg Capacity

24

-

-

... More
Fire bucket

12

-

-

... More
LABORATORY EQUIPMENTS

-

-

-

... More
PH meter

1

-

-

... More
Incubator

1

-

-

... More
Laminar flow

1

-

-

... More
Autoclave

1

-

-

... More
Microscope-binocular

1

-

-

... More
Chemical, Media and reagents

1

-

-

... More
Glass wares

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.