INKEL Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

INKEL Limited - INKEL Tender

Eprocure
Opening Date27 Feb 2021
Closing DateCancelled
Tender Amount₹ 5,68,37,240 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Aluminium Grid Flase Ceiling :- Providing & Fixing of ‘Lay in Plain metal ceiling’ consisting of 600x600mm Lay in tiles laid on grid systems . The grid system provided shall be T - sections of Flange width 15mm and web height 32mm, having rotary stitching on all T sections. The Suspension system shall consist straightened M6 Anchor Fasteners with Vertical Hangers made of Galvanized steel of size 26 x 26 x 25 x 1.2mm with Adjustable hook clip.The main runner shall be spaced at 1200mm centres securely fixed to the structural soffit using The suspension system at 1200mm maximum centre. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall. Flush fitting cross trees are used to form 600x600mm grid. The materials used and installation provided shall be as per the particular specification and as directed by Engineer in charge. Tile and grid elements provided shall be of white in colour

481.56

-

-

... More
JOINERY

-

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

180

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

103.5

-

-

... More
9.24.1 : Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded ) (overall area of door shutter to be measured):Rectangular or square

103.5

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

5

-

-

... More
Supplying and providing SS ball bearing of sizw 100x89x3 mm hinges.

180

-

-

... More
9.126.2 : Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Fire retardant plywood conforming to IS : 5509

36.47

-

-

... More
13.58 : Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant .

248.4

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

197.9

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

50.31

-

-

... More
9.106.2 : Providing and fixing PTMT handles with necessary screws etc. complete.150x34x24 mm weighing not less than 26 gms

66

-

-

... More
9.108.2 : Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms

66

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

672.18

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

1149.7

-

-

... More
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

54.39

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

177.3

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

54.39

-

-

... More
Aluminium louvered Ventilators - Providing and fixing powder coated Aluminium louvered Ventilators (minimum thickness of powder coating 50 microns) of approved colour HINDALCO or equivalent 9771, with 5mm thick frosted glass of approved make for aluminium U channel louvers including necessary grooves in frames for fixing glass etc. complete as per drawing. The cost shall be inclusive of all materials, labour, lift, lead, transportation etc. all complete.

3.6

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top pivot & bottom floor spring ( 200kg) type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).

4.8

-

-

... More
Providing and fixing Stainless Steel Corner Patch Lock with Strike Plate of SSS finish for toughened glass door including all necessary fittings Or equivalent.

2

-

-

... More
Providing and fixing Stainless steel D type glass door handle with SSS polished finish of 25mmx450mm size.

2

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

44

-

-

... More
21.11.2 : Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm

105

-

-

... More
21.11.3 : Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.355 x 19 mm

314

-

-

... More
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

13

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

17

-

-

... More
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm

104

-

-

... More
9.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm

26

-

-

... More
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

71

-

-

... More
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm

18

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

71

-

-

... More
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

18

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

34

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

209

-

-

... More
10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

19.26

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

13.86

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

6

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

3.1

-

-

... More
13.85.2 : Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With ready mixed red oxide zinc chromatic on steel / iron works having VOC content less than 250 grams/ litre

42.37

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

239.47

-

-

... More
Providing and fixing 1 mm thick M.S. sheet door with shutter frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings with outer frame of size 50x50x6 mm complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

13.5

-

-

... More
Compound wall & Gate

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

29.92

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

7.48

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

50.49

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

913.5

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

360

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

112.2

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

72

-

-

... More
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

11.94

-

-

... More
50.4.1.1 : Providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc.

3.6

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

4.21

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

7

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

52.5

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

603.75

-

-

... More
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

301.88

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

301.88

-

-

... More
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes

997.48

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

46.8

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

46.8

-

-

... More
External infrastructure

-

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-40 grade with approved color design and pattern.

804.96

-

-

... More
11.45 : Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mmthick sub grade of compacted bed of 20 mm thick nominal size stone aggregateand base course and filling with 150 mm thick jamuna sand, including spreading,well ramming, consolidating and finishing smooth etc. all complete as per directionof Engineer-in-charge.

374

-

-

... More
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes

3100

-

-

... More
Poly carbonate sheet roofing -Supply and installation of 2mm thick Poly-carbonate sheet roofing of approved make, embossed clear with UV protection coating/treatment and weight not less than 2400 gms/ sqm. It shall be fire retardant and confirming to IS 14443. the rate shall include aluminium leak proofing and fixing management system with EPDM rubber gaskets, silicone sealant etc. complete as required and as per the direction of engineer in chargeexcluding purlins, rafters and trusses and including cutting to size and shape wherever required.

155

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

10237.5

-

-

... More
Supply and Installation of color coated 0.5 TCT galvalume profile sheet including vertical/curved surface of overall width 1072mm(nominal 1015 mm effective cover width)and nominal 28mm deep ribs with subtle square fluting in the five pans at nominal 203 mm cente-to-centre.The end rib shall be designed for anticapillary action,to avoid any seepage of water through the lateral overlap, filled with white lead continuous spacer tape 6.4mm thick x 6 mm wide at all joints and junctions along its length.The feed material shall be of .45 mm BMT(.50 mm TCT excluding paint thickness)COLORBOND steel-Hi tensile with min 550 MPa yield strength,metallic hot dipped coated with Aluminium Zinc alloy (55% Aluminium 43.5% Zinc,1.5% Silicon) as per AS 1397/ IS 15961-Zincalume AZ150(Min 150gms/sq.mt total on both sides with Super durable Polyester COLORBOND steel quality paint system of approved color,suitable for exterior application confirming to AS/NZS 2728 type-4.The sheet shall have a total coating thickness of 35 microns,super durable polyester COLORBOND quality paint system of 20 micron reverse polyester coat on back surface over 5 micron primer coat on both surfaces.The rate includes with necessary fittings ,cutting to size and shape where ever required.

409.5

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

409.5

-

-

... More
Providing and fixing ridges and hips in roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. : Using colour coated Aluminium sheets of guage 18

27.59

-

-

... More
Providing and fixing PVC eaves of facia with 150mm width in required pattern and quality including fixing with nuts and bolts etc.complete.

15.8

-

-

... More
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2

56.6

-

-

... More
Providing and fixing 160 dia PVC rain water gutter (pressure class 4Kg/sq.cm )with necessary iron brackets bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.

56.6

-

-

... More
Providing and fixing rectangular Sheet Moulding Compound water storage loft tank with cover of approved make, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet &over flow pipes. The base support i/c fittings fixtures for tank shall be paid separately.

50000

-

-

... More
SH - 2 SANITARY FIXTURES

-

-

-

... More
Providing and fixing White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF Dual Cistern, overall size 765 x 370 x 650mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion/ rawl sleeves, gasket etc. complete, and fixing to wall, as per manufacturer's instruction and to the approval of Engineer-in-charge. Model Hindware 20096/21056 or equivalent

17

-

-

... More
Providing and fixing sanitary fixtures for handicapped toilet including one number Extended wall mount closet with soft close seat cover and cistern one wash basin, one pair mounting brackets,one number elbow operated pillar cock and all other related fittings like waste coupling one number hinged rail 76 cm & 4 nos. of grab rails 60cm etc designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge. Model Hindware 20096/21056, 10087, F280001MD, 510880, 501894, & Parryware T9911A1 or equivalent

4

-

-

... More
17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brasspillar taps

16

-

-

... More
17.7.9 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked

2

-

-

... More
17.80 : Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge.

4

-

-

... More
8.10.2 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade

2

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

65

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

21

-

-

... More
18.22.1 : Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter

9

-

-

... More
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore

9

-

-

... More
Hot & cold CP aerator wall mixer unit - Providing, Fixing, testing and commissioning Of Hot & cold CP wall mixer unit with long bend pipe for overhead shower with all accessories. Model Parryware T4616A1 or equivalent

2

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

11

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

29

-

-

... More
17.11.2 : Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm

10

-

-

... More
Providing, fixing, testing, and commissioning at site Single Lever Surgical Purpose Elbow Action Sink Mixer (Wall Mounted)with aerator Extended Operating Lever, Connecting legs & wall flanges, 15mm. nominal bore, including all necessary accessories, all as per manufacturer's instruction and to the approval of the Engineer-in-charge. Model: Jaquar FLR-CHR-5166

6

-

-

... More
Providing, fixing, testing, and commissioning at site Kitchen Sink Cock with aerator, Wall Mounted Type 15mm. nominal bore, overall dimensions: 208x237mm, including all necessary accessories, all as per manufactures instruction and to the approval of the Engineer-in-charge. Model Kerovit KB111025 or equivalent.

4

-

-

... More
C. P. Robe Hook,60mm. Dia. x 45mm. High. Model: Cera F5003108SS or equivalent

32

-

-

... More
17.34.1 : Providing and fixing toilet paper holder:C.P. brass

1

-

-

... More
17.72 : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms

2

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

11

-

-

... More
Supplying, installing, testing & commissioning at site in position Heavy Duty Flexible Braided Connectors, 15mm. nominal bore, 450mm. Long with higher thermal stability for cold and hot water for Geyser points of approved quality.

12

-

-

... More
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore

32

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

18

-

-

... More
Providing,fixing testing and commissioning Energy Efficient Storage Type Electric Water Heater, 2kw each, as per specification Capacity 15 Ltrs

6

-

-

... More
17.28.1.2 : Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe40 mm dia

22

-

-

... More
Providing,fixing testing and commissioning 11/2"x 40x300 Plastic P Trap (P Trap) for Sink. Adjusting pipe 120mm, drain elbow 220mm.

10

-

-

... More
INTERNAL DRAINAGE

-

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends,'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).Core Cutting in RCC Structure shall measured separately.Clamping details - For Vertical Shafts G.I.'U' bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 "STD Powder Coated Clamping details - For Suspended lines G.I.U bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.110mm OD

85

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, Y, bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).Core Cutting in RCC Structure shall measured separately.Clamping details - For Vertical Shafts G.I.U bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2"STD Powder Coated Clamping details - For Suspended lines G.I.U bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.75mm OD

30

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends,'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical &Horizontal Shaft piping for rainwater/Vent).Clamping details - For Vertical Shafts& G.I.'U' bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2"STD Powder Coated Clamping details - For Suspended lines G.I. U bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.110mm OD

110

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends,'Y',bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).Clamping details - For Vertical Shafts G.I.'U'bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2"STD Powder Coated Clamping details - For Suspended lines G.I.'U'bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.75mm OD

30

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe of 10Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, Y,couplings, adapters & clamping with Universal clamps 1mtr spacing, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site 32 mm OD (10kg/cm2)- for sunken drain

26

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe of 6Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, Y,couplings, adapters & clamping with Universal clamps 1mtr spacing, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil &Waste pipes -Internal).40 mm (IS 4985,6kgf/cm2)

30

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe of 6Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, Y,couplings, adapters & clamping with Universal clamps 1mtr spacing, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil Waste pipes -Internal).50 mm (IS 4985,6kg/cm2)

45

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe of 6Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, Y, couplings, adapters & clamping with Universal clamps 1mtr spacing, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil &Waste pipes -Internal).63 mm (IS 4985,6kgf/cm2)

35

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil &Waste pipes -Internal).75mm OD

250

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil &Waste pipes -Internal).110mm OD

210

-

-

... More
Deep Seal uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position Deep Seal (7") uPVC Fabricated Multi Floor Trap, with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, Anchor fasteners etc. complete in all respects - 50/75 mm dia inlet/outlet (In Ceiling)

52

-

-

... More
uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost of cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken)

2

-

-

... More
Supplying, installing, testing & commissioning at site in position 110mm dia deep seal PVC P Trap with boss tee and access cap including all necessary fittings and supports complete.

2

-

-

... More
C.P. cast brass or stainless steel Square Flat cut lock anti cockroach grating cover - Providing and Fixing Heavy Duty Stainless Steel Square Flat cut lock anti Cockroach Trap Stainless Steel A ISI 304 with 125x125 mm. Grating, for 110mm. Floor Traps.

54

-

-

... More
Heavyduty stainless steel cover for Concealed Floor Trap for Urinal - Providing and Fixing 125x125mm dia Heavyduty stainless steel cover for Concealed Floor Trap ISI 304 Cover, for Urinal.

2

-

-

... More
Heavyduty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required.

2

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

8

-

-

... More
WATER SUPPLY

-

-

-

... More
18.8.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes

5

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

290

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

350

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

115

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

50

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

30

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 20 mm nominal outer dia. Pipes.

60

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 25 mm nominal outer dia. Pipes.

45

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 32 mm nominal outer dia. Pipes.

85

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 40 mm nominal outer dia. Pipes.

25

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 50 mm nominal outer dia. Pipes.

40

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes.

15

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 80 mm nominal outer dia. Pipes.

20

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 40 mm nominal outer dia. Pipes.

40

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes.

40

-

-

... More
18.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

60

-

-

... More
18.18.3 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore

8

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

5

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

4

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

2

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

1

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal

1

-

-

... More
Brass Automatic Air Release Valves - Providing, Fixing, testing and commissioning at site in positions Brass Automatic Air Release Valves, of approved quality and make on the top of the vertical water supply pipes as per specification and drawing - 3/4"(20mm) dia

6

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN 6) of approved make with PP float & nipple with brass threaded add, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 40mm dia (11/2")

1

-

-

... More
Supplying, installing,Testing & commissioning at site in position Multi Jet Water Meter with unions of removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totaliser,retrofitable for pulse output and conforming to ISO-4064 Class B complete.Water meter40mm

2

-

-

... More
VALVES (Electrical)

-

-

-

... More
16.11.1.7 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 50 mm dia

3

-

-

... More
16.11.1.6 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 65 mm dia

5

-

-

... More
16.11.1.5 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 80 mm dia

2

-

-

... More
CI Y Strainer 2"(50mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects

2

-

-

... More
CI Y Strainer 2 1/2"(65mm) dia - Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects.

1

-

-

... More
CI Y Strainer 3" (80mm) dia - Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
EXTERNAL SEWARAGE & STORM WATER DRAIN

-

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation)160mm OD

50

-

-

... More
Supplying, Installing &Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation)110mm OD

40

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation)75mm OD

15

-

-

... More
19.30.1.1 : Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

-

... More
19.7.1.2 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885

8

-

-

... More
19.8.1.2 : Extra for depth for manholesSize 90x80 cmWith Sewer bricks conforming to IS : 4885

4

-

-

... More
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With Sewer bricks conforming to IS: 4885

5

-

-

... More
4.1.10 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

18

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

90

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 160mm dia.

1

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 110mm dia.

95

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 75mm dia.

1

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 63mm dia.

14

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 50mm dia.

24

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 40mm dia.

2

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 32mm dia.

26

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 100mm (4")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 100mm(4") uPVC Astm Sch 80 Puddle flange

9

-

-

... More
Supplying, Installing &Testing at site in position Fabricated 80mm (3")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 80mm(3") uPVC Astm Sch 80 Puddle flange

3

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 65mm (21/2") uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 65mm (21/2") uPVC Astm Sch 80 Puddle flange

2

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 50mm (2")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 50mm(2") uPVC Astm Sch 80 Puddle flange

1

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 40mm (11/2")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -40mm (11/2")uPVC Astm Sch 80 Puddle flange

1

-

-

... More
PLUMBING PUMPS & TANK

-

-

-

... More
Vertical multi stage centrifugal pumps (surface pump) for Domestic Water Supply - Supply, Installation, Testing and Commissioning 2 nos, Vertical multi stage centrifugal pumps (surface pump) set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 11 lps @ 40mtr head, Head range 15 to 55 mtrs (20 lps to 5 lps), "F"class Insulation, IE3 Rated Electric Motors, IP 55 Protection, Hydraulic efficiency more than 67% motor efficiency more than 85% with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) Star Delta,having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function, Digital display,Pressure gauge, Float Switches, Auto/Manuel Operation . The total system shall be assembled and tested at factory as per the duty conditions. (For Domestic Water from sump to OHT)

1

-

-

... More
Open well Submersible Pump set for Flush Water Supply-Providing,fixing,testing and commissioning 2 nos, Open well submersible pump set, having SS: Shaft and CI Casing,impeller,Each pumps should be capable to deliver 5 lps @ 28 mtr head Head range 8 to 36 mtrs, with 3.7 kW/5 HP.with motor efficiency more than 85% with Wall mounting Microprocessor based common control Panel to operate the pump set as (1 Working+1 Standby ) having features of automatic pump change over in every start, Star Delta starter, Dry run, Overload, Phase Reversal Protection set c.level controller for Auto Start/Stop Function, Digital display, Pressure gauges ,Isolation valves, Non Return Valves, Float Switches, Auto/Manuel Operation. (For Flush Water from STP to Sump)

1

-

-

... More
Sewage Solid handling pumps - Supply, testing and commissioning of Submersible non clog Sewage Solid handling pumps. Control Panel for Controlling 2 Pumps, having SS Shaft and CI/SS Casing & Impeller, IP 68 Protection Each pumps should be capable to deliver 4 lps @ 10mtr head for each pump, solid handling 50mm with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) having features of Cyclic Timer for Cascading Operation and Float Switch/Probe Suitable for Automatic Operation. The Panel should have the following Protection for Single Phase Prevention, Over Load Protection, Over /Under Voltage Protection, Dry Running Protection, Transient Surge Protection, with Auto/Manual Operation & Auto coupling . The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication(Modbus). (For Medical Waste Tranfer Pump)

1

-

-

... More
Sewage Solid handling pumps - Supply, testing and commissioning of Submersible non clog Sewage Solid handling pumps. Control Panel for Controlling 2 Pumps, having SS Shaft and CI/SS Casing & Impeller, IP 68 Protection Each pumps should be capable to deliver 3 lps @ 10mtr head for each pump, solid handling 50mm with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) having features of Cyclic Timer for Cascading Operation and Float Switch/Probe Suitable for Automatic Operation. The Panel should have the following Protection for Single Phase Prevention, Over Load Protection, Over /Under Voltage Protection, Dry Running Protection, Transient Surge Protection, with Auto/Manual Operation & Auto coupling . The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication(Modbus). (For Medical Waste Tranfer Pump)

1

-

-

... More
FILTER FEED PUMP SET.Supply, Testing and Commission Filter Feed Pump Set, Submersible Type for Pumping Raw Water to Water Treatment Plant, 2 Pump System with One Working + 1 One Cyclically Stand by Pumps, each Pump of Capacity: 10M3;/Hr. @ 45Mtr. Head, having SS Impeller, Shafts, Casing, with 3Ph, complete with Microprocessor Based Control Panel, for Auto and Cyclic Operation, with all Protection (Digital display, Low & high voltage protection, dry run, phase reversal, pump over load, etc.), Level Sensors / Float Switches in Treated Water & Raw Water Tanks and Control Cabling / Wiring between Level Sensors / Float Switches and Control Panel, Delivery Manifold, Isolating Valves, Non Return valves, Pressure Gauge, Fittings, Stainless Steel (Grade:304) Lifting Chains, Accessories etc. all as per Technical Specifications.The Control Panel shall be capable operating the pumps (starts and stops) by sensing the level difference in water in the Treated Water Tank. Also; capable of not starting or stopping the running pumps, when the water in the underground Raw Water Tank goes below the pre-set minimum level. The Pumps to be installed in the Underground Raw Water Tank and Common Control Panel in the Pump Room, in Basement Floor, approx. 100 Mtr. away from Raw Water Tank. The Underground Power Cabling between Pumps and Control Panel and Control Cabling between Control Panel & Level Sensor / Float Switch, in the Underground Raw Water Tank, shall be measured as a part of Electrical Work. The Quoted Price for the Pump Set shall be inclusive of all above requirement, necessary Level Sensors / Float Switches, Power Cabling, Control Cabling etc, except what measured as a part of Electrical Work, as detailed above.

1

-

-

... More
Supply, Testing and Commission Submersible Type Storm Water Transfer Dewatering Pump Set, complete set with 1 working + 1 Standby Submersible non- clog pump , Solids handling: 40mm , and with Common Control Panel for automatic operation and Manually change over facility. Capacity 12 M3/Hr. at 10 Mtrs. head, each, with Three Phase with float switches/level sensors etc. necessary control valves, Pressure Gauges fittings and accessories, for discharging rain water from collection pits in basement floor, to lower strata. The price shall inclusive of all connected electrical work as detailed in the technical specification.

1

-

-

... More
18.48A : Providing and fixing rectangular high density polyethylene water storageloft tank with cover, conforming to ISI : 12701, colour of opaque white or asapproved by Engineer-in-charge. The rate includes making necessary holesfor inlet, outlet & over flow pipes. The base support i/c fittings & fixtures fortank shall be paid separately.

4000

-

-

... More
WATER TREATMENT PLANT

-

-

-

... More
Supply, Installation, testing and commission Water Pre-Treatment Plant Capacity: 10M3 /Hr, for continuous operation of 10 Hr, complete with High Pressure Sand Filter, Activated Carbon Filter,with Multiport valves, Chemical Dosing etc as per final requirement, connected Pipe Work etc, all as per Technical Specifications.Filter Feed Pumps shall be measured seperately.

1

-

-

... More
SEWAGE TREATMENT PLANT

-

-

-

... More
Supply, installation, testing and commissioning of Sewage Treatment Plant (MBBR Type) of 50 KLD capacity with Ultra Filter & F.R.P tanks.All Plumbing and Electrical panel, Cabling included as per attached specifications (Detailed Technical Specification Attached)

1

-

-

... More
SH - 3 - ELECTRICAL WORKS - POINT WIRING

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C.

379

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

26

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

145

-

-

... More
1.14.1 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

3038

-

-

... More
1.14.2 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

3726

-

-

... More
1.14.3 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

248

-

-

... More
1.14.4 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

50

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

75

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

50

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

50

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

74

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

50

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

150

-

-

... More
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

41

-

-

... More
Supplying and fixing suitable size modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required but excluding GI back box

149

-

-

... More
Supplying and fixing suitable size modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required but excluding GI back box

66

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required.

74

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

433

-

-

... More
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard-length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.

74

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. Upto 450 mm sweep

1

-

-

... More
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.

1

-

-

... More
DISTRIBUTION BOARD AND MCB

-

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

1

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

8

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door

5

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door

4

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door

2

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way (4 + 36), Double door

3

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.);4 way (4 + 12), Double door

3

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.);6 way (4 + 18), Double door

2

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.);8 way (4 + 24), Double door

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

368

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

17

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

10

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.

12

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

29

-

-

... More
MV and HT CABLE LAYING

-

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm

50

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm

25

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

1604

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

166

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

239

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

132

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

60

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

60

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 185 sq. mm and upto 400 sq. mm

58

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 185 sq. mm and upto 400 sq. mm

116

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

288

-

-

... More
Supply and laying of necessary dia. heavy duty HDPE pipe (as per Is 4984 PE-80 GRADE (Virgin ) material) PN - 6 for laying for 1RX3.5CX400 Sqmm A2XFY cable from existing substation to cancer block road crossing by horizontal drilling method including drilling, boring, rimming etc. The cost including all labour charges including digging the pit where ever necessary, supply and laying of HDPE pipe with all accessories as required as directed by the Engineer in charge.

60

-

-

... More
MV and HT cable jointing ,end termination and cable trays

-

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

4

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

4

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

4

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

4

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

8

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

10

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

4

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

4

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

6

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

20

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

14

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.;4cx6 sq mm;

50

-

-

... More
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

16

-

-

... More
Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. ;100 mm width X 60mm Height

26

-

-

... More
Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. ;200 mm width X 60mm Height

26

-

-

... More
od204892/2020_2021 : Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. <br>400 mm width X 60mm Height<br>

58

-

-

... More
DIESEL GENERATOR

-

-

-

... More
DIESEL GENERATORS Supply, installation, testing and commissioning of 3phase, 415V, 0.8pf 50hz. radiator cooled DG set of the rating 200 kVA standby Duty Diesel generating set comprising of diesel engine alternator, fuel tank, starting system, battery, battery charger, electronic governor etc. with all accessories required for synchronising (Future) the DG with another DGs. The battery charger of auxiliary DC power supply unit, with dry batteries with connecting leads and terminals with stationary type, high discharge performance, Valve Regulated Lead Acid (VRLA) sealed maintenance free, battery charger including all other accessories like interconnecting cables etc. as required. The Generator set shall have a integral type acoustic enclosure as per latest CPCB II norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with EURO-II specifications. ;Generator set with direct injection, 6 cylinder, 4 stroke, 1500 RPM conforming to ISO 3046/1 and BS 5514 inclusive of fly wheel, flexible coupling, heavy duty air cleaner, corrosion resistor, fan with guard, fuel pump, turbocharged exhaust manifold, SS exhaust flexible connections, plate type lube oil cooler, fuel filter, lube oil filter and by-pass, electrical starting system with starter, 2 X 12 V battery with regulator, instrument panel, rpm indicator, residential silencer, heavy duty air cleaner, lube oil/coolant heater with thermostatic switch, space heater for alternator, audio/visual annunciation for faults. The DG shall have the following facility like (a) External Start/ Stop using potential free contacts (b) External Engine Speed control using potentiofree contacts including droop setting (c) External DG terminal Voltage Control using potential free contacts. Also having facility of ECU for incorporating the above features. With microprocessor based controller. Silencer shall be suitably optimized to reduce noise, with sturdy base rail and 990L free standing fuel tank. Controller shall be equipped with auto, manual, start, stop, fault reset and lamp test/panel lamp switches with alpha-numeric displays and push buttons, indications for genset running, remote start, not in auto, common shutdown, common warning, manual run mode, auto mode, stop etc. with sync check. For alternator - line to neutral and line to line volts indication, current, frequency, kW, kVAr, power factor kVA and for engine following indications - DC voltage, engine speed, lube oil pressure, coolant temperature, coolant low level, comprehensive FAE data, with start/stop attempts, runnings hours, kW hours, load profile, fault history, data logging etc. and all data shall be recorded. ;200 kVA DG:- Alternator shall be self excited, self- regulated, with class H insulation, saient pole revolving field with PMG standard. Floor mounted dust and vermin proof, indoor type standard control panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors interlocked with the earth switch, comprising of one number Microprocessor based MCCB rating of 320 A, 4pole, 36 kA breaking capacity, thermal over load, voltage controlled O/C relay, over voltage, under voltage, negative sequence relay, voltmeter with selector switch, 3 ammeters of 0-320A range, frequency meter, kW, pf, electronic energy meter with CT, PT units and indicating lamps with fuse and switch control etc. as complete with necessary control wiring interconnections etc. including first filling of oil and diesel for commissioning &trial run of the DG set.(Energy meter&CTs shall be tested and certificate shall be obtained from electrical inspectorate lab) Following sanction may be obtained by the contractor:;(i) Sanctions from Municipality/ Corporation(ii) Sanction from Pollution control Board;(ii) Sanction from electrical inspectorate&;Outdoor acoustic enclosure with compartmentalized standard control panel for the DG set. The sound level shall be brought down to 70DB+/-5 with at a distance of 1m (as per CPCB norms the sound level shall be 75dB at a distance of 1m from the silencer at the top of the enclosure). The body shall be with 16 SWG corrugated painted G.I sheet, roof No 18 SWG corrugated, painted G.I sheet, inner shall be with 22 SWG Al perforated sheet with 2.5mm perforation. Body thickness shall be minimum 150mm. AMF logic with above mentioned breaker control panel shall be provided.

1

-

-

... More
EXHAUST PIPES; Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colours to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps angle, channel, I section, necessary nut and bolt and all required accessories including cutting, hoisting, fixing in position and applying 2 coats of primer and 2 coats of enamel paint of approved quality etc. as required in the steel works etc. as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust. Installation of exhaust system with mineral wool or rock wool 50mm thick wire mesh and aluminium cladding etc. as required .Exhaust pipe shall be B class G I pipe conforming to IS 3589 125 mm dia

35

-

-

... More
AUTO POWER FACTOR CORRECTION PANEL

-

-

-

... More
APFC PANEL Supply erection, testing and commissioning of 14 SWG freestanding indoor cubicle, type tested automatic power factor control panel of rating 100 kVAr with 7% harmonic reactor with tuned capacitors using capacitor switching. By using Microprocessor based relay operated controller with minimum 8 stage which should be capable to switch on the required kVAr for compensation based on cyclic switching. 250A 36kA 4P MCCB with high rupturing capacity and in built overload and short circuit releases as per specifications as incomer, housing capacitors with heavy duty polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes in steps of 8 (25 kVAr X 1), (20 kVAr X 2), (10 kVAr X 2) & (5 kVAr x 3) required rating of capacitor shall be directly connected to the main bus for no load compensation with the co-ordination of transformer manufacturer specification. The capacitors shall be with U.L listed pressure sensitive interrupter, inside hermetically sealed metal cans. with terminal bushings to withstand 10 KV AC to ground with treated terminals and capacitor cells shall be provided with discharge resistors to reduce residual voltage <50Vwithin one min of de-energisation. All controls shall be mounted on enclosure door with door interlocks. Heavy duty capacitor duty contactors with high rupturing MCB shall be used for individual stage control. Metering :Digital Multi Function Meter (DMFM) , Push Button, R Y B Indication with control fuse -1Set, Auto manual selector switch- 1No, Forced cooling using fans, APFC relay - 1 no. including all connections and interconnections, all accessories as required for complete installation as instructed by engineer in charge

1

-

-

... More
CABLES AND END TERMINATION

-

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3.5cx50 sq.mm

44

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3.5cx35 sq. mm

32

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3.5cx70 sq.mm

62

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3.5cx120 sq.mm

216

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date.3.5cx185 sq.mm

48

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date.3.5cx240 sq.mm

28

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3.5cx300 sq.mm

104

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3.5cx400 sq.mm

156

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 2x6sq.mm Al Cable

229

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. ;2CX4 Sq.mm Al Cable

204

-

-

... More
Supply and laying and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in medium duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages colour washing etc. as required. and instructed by engineer at site/consultant.;1CX25 Sq.mm Copper Flexible Cable

120

-

-

... More
Supply and laying and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in medium duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages colour washing etc. as required. and instructed by engineer at site/consultant.;4x2.5sq.mm Cu Control Cable

150

-

-

... More
Supply and laying and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in medium duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages colour washing etc. as required. and instructed by engineer at site/consultant.;12CX2.5 sq mm

266

-

-

... More
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.1CX25 sq.mm Cu Cable

20

-

-

... More
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 4Cx2.5 Sqmm Control cable

4

-

-

... More
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.;12Cx2.5 Sqmm Cu Control cable

4

-

-

... More
LIGHT AND FAN FIXTURES

-

-

-

... More
Supply of recess mounted LED fitting 36W(+/- 10% Tolerance) of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 80 lm, with a CRI of 80 or above, ANSI rated,(icu dimmable) LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Wipro LM38-461-ANA-57-DL or equivalent

40

-

-

... More
Supply of of recess mounted 31W(+/- 10% Tolerance) LED luminaire of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor 0.9,THD;10%, rated life of 50,000 hours, system efficacy greater than or equal to 110 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture.<br>Makes: Philips: RC380B LED36S-5700 G5 L60W60 PSU OD, Wipro: CRCO10R030HP57HE, Bajaj: BZRSQL 30L XE WH OD SD&

26

-

-

... More
Supply of Surface mounted LED 4X1 LED luminaire with luminaire wattage should not exceed 31W and nominal system lumens not less than 3000 Lumens. The luminaire should have a colour temperature of 5700K and CRI80. Diffuser material should be of Polycarbonate PMMA and housing shall be powder coated CRCA.. Driver of the luminaire shall have THD10% and PF ; 0.9. The driver shall comply to IEC standards. Similar to Wipro Make CRCO13S038HP57G1 - Environmental friendly, new generation, aesthetically designed, ultra modern Surface mounting luminaire with high brightness SMD LED as light source. Similar to Wipro Make Model No: CRCO13S038HP57G1 or equivalent.

63

-

-

... More
Supply of recess mounted 24W(+/- 10% Tolerance) LED luminaire of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 110 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridge lux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture.<br>Makes: Philips- RC380B LED30S-5700 G5 L60W60 PSU OD, Wipro-CRCO10R024HP57HE, Bajaj:BZRSQL 24W XE WH

44

-

-

... More
Supply of recess mounted Downlights of 18W(+/- 10% Tolerance) LED luminaire of Die Cast Aluminium Housing, driver with minimum 4KV Surge protection, power factor 0.9,THD;10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- DN194B LED16S-5700 PSU WH S2, Wipro- CRDL11R023HP57, Bajaj: BZSLO 18W WH PRO.

27

-

-

... More
Supply of Recessed mounted Square LED Downlighter, high efficiency with a nominal system lumen output of 1527 lumens. Luminaire wattage should not exceed 18W. The luminaire should have a  CRI80. Driver of the luminaire shall have THD20% and PF 0.9. The heat sink should be made of die cast aluminium and the luminaire optics shall have a high efficiency PC diffuser. Aesthetically designed 1X1 LED flat panel of surface mounting which provides soft-light and glare free symmetrical illumination. Similar to Wipro make Model No: LD81-171-XXX-60-XX or equivalent.

38

-

-

... More
Supply of Surface mounted Down lights of 15W(+/- 10% Tolerance) LED luminaire of driver with minimum 4KV Surge protection, power factor0.9,THD;10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridge lux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture.<br>Makes: Philips- SM250C LED16S- 6500 PSU WH, Wipro- LD81-131-XXX-60-SM, Bajaj: BGSLO SLEEK SURFACE 15W WH RD

47

-

-

... More
Supply of LED Tube Lights of 20W(+/- 10% Tolerance) with Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia-Japan/ Cree-USA / Bridgelux-USA / Lumiled-USA / Citizen-Japan / Osram should be provided and including all necessary accessories as required for the light fixture. ;Makes: Philips- BN308C LED20S-6500 L120 PSU WH, Wipro- LL24-251-XXX-57-XX, Bajaj: BCLAB 20W

135

-

-

... More
Supply of LED Tube Lights of 40W(+/- 10% Tolerance) with Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor 0.9,THD;10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Philips- BN308C LED40S-6500 L120 PSU WH, Wipro- LL24-541-XXX-57-XX, Bajaj: BCLAB 40Wt;

26

-

-

... More
Supply of Bulkhead of 10W(+/- 10% Tolerance) with polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor 0.9,THD10%, system efficacy greater than or equal to 80 lm, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). ;Makes: Philips, Wipro, Bajaj.

13

-

-

... More
Supply, installation, testing and commissioning of analogue controller for above fixture, with SS finish, control up 20 luminaire including necessary back box, front plate, cover plate, connections and inter connections as per the direction of Engineer in charge. Similar to Wipro Make cat No: 140-202 or equivalent.

4

-

-

... More
Supply, fixing, testing and commissioning of 5 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimensions 200mm length x 200mm breadth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 16 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO. Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall be with one arm of minimum 0.5 meter long for fixing 45 W LED fixture (Similar to Wipro make : LR02-501-XXX-57-XX LED Street Light). The cost inclusive of all material required for complete installation including light fixture, pole, foundation etc. required as per the specification.

2

-

-

... More
Supply, fixing, testing and commissioning of 3 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimensions 200mm length x 200mm breadth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 16 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. <br>The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO. Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall be with one arm of minimum 0.5 meter long for fixing 25 W LED fixture (Similar to Wipro make : LR06-311-XXX-57-XX LED Street Light). The cost inclusive of all material required for complete installation including light fixture, pole, foundation etc. required as per the specification.

8

-

-

... More
Supply and installation, testing and commissioning of Aviation obstruction light with built-in 75VA step up transformer with yellow coloured die cast aluminium alloy housing, Neon spiral lamp plugged into spring loaded high tension nylon socket and wired upto the terminal block., heat resistant, clear, toughened, thick glass dome mounted on hinge die cast aluminium ring secured to the body by two studs and wing nuts, 38mm dia threaded stem with lock nuts for mounting on pipe above structure, heavy duty and weather proof, indicating aviation obstructions in flying paths and provide light with 360 Deg visibility. The enclosure shall be IP 54. It shall be designed to meet International Civil Aviation Organisation Standards. Operating Voltage 230 V AC. Power Consumption > 5W. Light Intensity > 15 cd. Average life time 50,000 hrs at 70 % lumen maintenance. (Bajaj make BJOL 1 or equivalent)

1

-

-

... More
FAN FIXTURES Supplying of ceiling fan of 1200mm sweep, energy efficient 5 Star rated, BLDC motor, High Speed, high power factor above 0.95 including the down rod of standard length (upto 30 cm).

74

-

-

... More
Supply, installation, testing and commissioning of wall fan of 450mm sweep, 1200 RPM, 70 Cu.Mtr/Min Air delivery. Plastic body & blades with pull cords for speed regulation wide oscillation control. Aerodynamically designed blades for high air efficiency.

1

-

-

... More
MISCELLANEOUS

-

-

-

... More
PVC FLEXIBLE CONDUIT Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required25mm dia

30

-

-

... More
Supply and clamping the following size of corrugated pvc flexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required20mm dia

50

-

-

... More
Supplying, fixing, testing and commissioning following four pole / double pole, 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.25A, 30mA, DP RCBO

7

-

-

... More
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..;40A 100mA FP RCBO

8

-

-

... More
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DBs complete with connections, etc. as required and instructed by engineer in charge/consultant..25A 30mA FP RCBO

6

-

-

... More
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..25A 100mA DP RCBO

2

-

-

... More
Supplying, fixing, testing and commissioning following four pole / double pole, 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB;s complete with connections, etc. as required and instructed by engineer in charge/consultant.40A, 100mA, DP, RCBO

8

-

-

... More
Supply, fixing, testing and commissioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spreader links, terminal connections and all accessories as required making all necessary connections etc. as required and instructed by engineer in charge/consultant.;63 Amp 25kA FP MCCB with Thermal - Magnetic Release

4

-

-

... More
Supply, fixing, testing and commissioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spreader links, terminal connections and all accessories as required making all necessary connections etc. as required and instructed by engineer in charge/consultant.80 Amp 25kA FP MCCB with Thermal - Magnetic Release

1

-

-

... More
Supply, fixing, testing and commissioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spreader links, terminal connections and all accessories as required making all necessary connections etc. as required and instructed by engineer in charge/consultant.100 Amp 16kA FP MCCB with Thermal - Magnetic Release

2

-

-

... More
MCCB:t;Supply, fixing, testing and commissioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spreader links, terminal connections and all accessories as required making all necessary connections etc. as required and instructed by engineer in charge/consultant.t;100 Amp 25kA FP MCCB with Thermal - Magnetic Release

2

-

-

... More
Wiring for Staircase Light Point<br>"Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all accessories required for complete installation etc. , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all accessories required etc. and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required and instructed by engineer in charge/consultant. ;(Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms)One light point controlled by one way switch (at ground floor)

2

-

-

... More
Wiring for Staircase Light Point Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all accessories required for complete installation etc. , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all accessories required etc. and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required and instructed by engineer in charge/consultant. {Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms);Loop wiring for Light point

24

-

-

... More
Computer Point; Wiring for computer point using 2 Nos 6A plug points controlled by 2 Nos independent 6A switches using 1.5 sq.mm FRLS PVC insulated copper single core stranded wire and earthing using using 1.5 Sqmm FRLS PVC insulated copper single core stranded wire, green colour continuous run thorough conduit as per IS, earthing etc. in surface/ recessed medium class PVC conduit including all accessories as required for complete installation and as directed by engineer in charge and making good all damages made for installation. Cost inclusive of sockets, switches, suitable cover plate and base plate and suitable size GI box with all accessories required for complete installation etc. Circuit main shall be measured separately (Separate colour shall be provided for switches, faceplate and cover plate and same shall be finalized with site in charge / client).

28

-

-

... More
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc. as required and as instructed by engineer in charge also making good any damages made during installation32A FP Isolator with enclosure

6

-

-

... More
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc. as required and as instructed by engineer in charge also making good any damages made during installation.25A FP Isolator with enclosure

4

-

-

... More
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc. as required and as instructed by engineer in charge also making good any damages made during installation.50A FP Isolator with enclosure

5

-

-

... More
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc. as required and as instructed by engineer in charge also making good any damages made during installation.;63A FP Isolator with enclosure

2

-

-

... More
Supply, installation, testing and commissioning of following rating SP/TP C curve MCB, 16kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and interconnections as required and as instructed by engineer in charge/consultant. 6-32 TP MCB

17

-

-

... More
Supply, installation, testing and commissioning of following rating SP/TP C curve MCB, 16kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and interconnections as required and as instructed by engineer in charge/consultant. ;40A TP MCB

26

-

-

... More
UPS

-

-

-

... More
Supply Installation; and commissioning of 30kw Power cabinet with 25kw Modules UPS Three phase in and out with min 5 modules with vertical & horizontal paralleling of power modules Compatibility , and independent phase management, with indoor (IP21) with surge protection system with 15 min backup battery @ 25kw Unity PF load (SMF battery of reputed approved make Exide/Amron), with battery bank with Min VAH 16320 with dual battery string per UPS, Input pf 0.99, input THDi 3 % without additional filter, double conversion technology with input voltage range 320-460 @ full load, 50Hz Three Phase, output 400V, 50Hz Three phase, SNMP card for network monitoring, compatibility  etc. It shall be 100% generator compatible, with Efficiency @ 96% and output power factor unity ( 25kVA= 25kW), Eco mode Efficiency 98% and including all accessories etc. as required. The system shall comply to The acoustic noise at 1m of the system should be <62dB. and IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, PEP (LEED) and relevant IS standards. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic bypass built-in. The system shall have IGBT rectifier and inverter. warranty 2 years for UPS and batteries.

1

-

-

... More
LIGHTNING AND EARTHING PROTECTION

-

-

-

... More
LIGHTNING PROTECTION Supply, installation and testing of 3 meter air terminal with accessories, providing and fixing air terminals as per IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod 4 meter rod: Meets the technical specification according to DIN EN 50164 - 2 (VDE 0815 part 202). Meets the requirement of VDE0185/305 (IEC 62305) 101 VL 4000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. 2 nos of 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked, including all accessories as required for complete installation as instructed by engineer in charge.

1

-

-

... More
Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance, including all accessories as required for complete installation as instructed by engineer in charge. A) Vertical run- Down conductor

349

-

-

... More
Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance, including all accessories as required for complete installation as instructed by engineer in charge.;b) Horizontal run-Parapet application

185

-

-

... More
Supply and installation of 8mm solid aluminium round conductor: For TERRACE APPLICATION Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Stainless steel base with Polyamide Conductor holder top: Adjustable width from 185-260mm. Infinitely adjustable conductor holder. Fast installation using wing screw. Bottom section with 8.5mm diameter slot With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance

51

-

-

... More
Supply and fixing of cross connector / T connector: to route vertical down conductor /mesh formation made of stainless steel/hot dipped galvanised iron with necessary screws etc. as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts and all accessories as required for complete installation

24

-

-

... More
Supply and fixing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305) and all accessories as required for complete installation

12

-

-

... More
Supply and Fixing Equipotential bonding rail for Lightning Arrestor applications (Test Joint). Equipotential bonding rail for equipotential bonding according to DIN VDE 0100-410/540 and lightning protection equipotential bonding according to DIN VDE 0185-305. Base plate and cover hood from polystyrene. Colour: Black, UV resistant. Can be used outdoor also. Screw and crossbar made of VA. Capable of carrying lightning current 100KA (10/350). Connection options: 7 x single or multi-core conductors to 25mm square or fine core conductors to 16mm square. 1 x round cable Rd 8-10. 1 x flat strip to FL 30 or round cable RD 8-10 including corrosion tapes and all accessories as required for complete installation as instructed by engineer in charge.

12

-

-

... More
Supply and laying hot dip Galvanised Steel Flat having 70 microns zinc 30X3 mm thick from earth electrode directly in ground as required. Hot Dip GI strip, corrosion resistant. Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IEC 62305) Zinc coating: 500 g/m square (70 micron coating) Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding including cross connectors and all accessories as required for complete installation as instructed by engineer in charge.

222

-

-

... More
Supply and fixing of PVC trapezoidal 1.5m long ducts including the fastening clamps and all accessories as required

12

-

-

... More
Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate

12

-

-

... More
Supply, installation and testing of maintenance free Earthing system as per IS 2309 ,IEC 62305 part3, IEC 60364, IEC 62561 part 2, IS 3043, UL 467 & UL 96 standards. Earthing System comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length (1m (219 20 CU) x 3 nos), having a diameter of 20mm with copper coating thickness of 250 microns with self-coupling bore and peg arrangement (without the need for external coupler) with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. For obtaining desired length, the number of rods shall be increased and is provided with Universal Clamp (2730 20 VA) made of SS 304 for clamping the cable/flat conductor to the rod. Impact point (219 20 IP) on the bottom rod for easy insertion. Earth enhancing mineral compound (ECS PB 12.5) is used for improving the soil conductivity.t;Earth enhancing mineral compound shall be so designed and constructed that in normal use their performance is reliable and without danger to persons and the surroundings. The material shall be mineral inert to sub soil and shall not pollute the environment. It shall provide a stable environment in terms of physical and chemical properties and exhibit low resistivity. It shall not be corrosive to the earth electrode itself. The material should have a resistivity less than 0.2 Ohm meter. It should be free from hazardous substances The mineral compound is required to have minimum 12.5 Kg of the total composite. Polypropylene &Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 190mm with a weight bearing capacity of 5KN, including all accessories as required for complete installation as instructed by engineer in charge.;

4

-

-

... More
EARTHING;Supply, installation and testing of 1200mmx1200mmx12mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, CI cover, CI frame, GI watering pipe of 50 mm dia with funnel having 20G GI wire mesh etc. The CI cover frame/ chamber shall be of 1000mm x 500mm x 600mm size. CI manhole cover with frame shall be painted with bitumastic paint, identification of earth pit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. ( value of earth resistance should be less than 1 ohm )

8

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>25x3 Cu strips tinned at the joints

268

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>32x3 Cu strips tinned at the joints

110

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant.;40x6 Cu strips tinned at the joints<br>

115

-

-

... More
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant.t;25x3 Cu strips tinned at the joints

358

-

-

... More
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant; Copper wire No.10 SWG &

388

-

-

... More
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant; Copper wire No.8 SWG

1117

-

-

... More
RISING MAINS,BBT AND TAP OFF BOXES

-

-

-

... More
RISING MAINS, BBT & TAP OFF BOXES<br>Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated Sandwich type, epoxy insulated, compact, sandwiched indoor type (TPN) rising mains on wall, with high conductivity aluminium conductor in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections. end cap etc. . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The bus duct shall be complete with 4 nos aluminium Busbar. Earthing with 2 runs of copper earth of size 25 x 5 mm copper strip on each side including clamping bracket, angle iron bracket, steel fasteners, connecting to earthing system etc. as required, including supports for bus bars. The bus duct shall comply with IEC and BS standards. Each bus bar shall be individually insulated by means of Multi layer Class-F Insulation, Each layer shall have withstand breakdown voltage of minimum 6 kV. The insulation material used shall be of minimum Class F (155 deg. C). The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accessories required for complete installation.<br>250A Al TPN, 25 kA, IP54 Rising Mains

33

-

-

... More
Supply, installing, connecting, testing and commissioning of following capacity end feed unit suitable for Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The end feed unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of end feed unit shall be furnished 250 Amp 25kA FP MCCB with Thermal - Magnetic Release

1

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. ;125 A 25kA FP MCCB in Tap off box

2

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished.100 A 25kA FP MCCB in Tap off box

4

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. <br>63 A 25kA FP MCCB in Tap off box

2

-

-

... More
SAFETY EQUIPMENTS

-

-

-

... More
Supply and providing 2/3 mm thick synthetic type and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 5429/1969.

60

-

-

... More
Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.

2

-

-

... More
Supply and providing First Aid Box.

2

-

-

... More
Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.

1

-

-

... More
Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc. on good frame work.

1

-

-

... More
Supply and providing MS chequered plate of 6 mm thickness with MS supports including cutting, welding, painting etc. as required for cable duct covering etc.

25

-

-

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold or , duly painted over a coat of primer. Cost inclusive of providing 3 Nos of fire buckets and MS stand frame.

1

-

-

... More
Supply of 1 pair 11 KV rubber hand gloves of approved make.

2

-

-

... More
Supply and providing 12 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 11 kV dielectric strength conforming to IS 5429/1969

10

-

-

... More
LT PANELS

-

-

-

... More
MAIN PANEL Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV Main panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br>This panel should include Pluggable type surge arrester Class B & Class C / Class 1 & Class 2 as per IEC 61643 (IP 20) with potential free contact, completely assembled enclosure & provision for inbuilt common remote indication for defective arresters 3 Nos of encapsulated spark gap & 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage - 230V 50Hz, Impulse current-150 KA (10/350µ sec) & 60KA (8/20µ sec) for Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV (N to E). Operating temp -40º to +85ºC. Response time <100 nano sec including necessary MCCB for protection of same. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. ;IncomerEB Incomer 1 - 630A, 36kA, FP, Microprocessor based MCCB + 630A 4P Power Contactor - 1 Set.t;DG Incomer 1 &; 2 - 320A, 36kA, FP, Microprocessor based MCCB with Standby low set E/F relay with CT at neutral earthing conductor + 320A TP Power contactor + 125A FP Contact for neutral and earth - 2 Sets<br>630A, 415V, 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, Current, Frequency, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interrupts, Phase angle, THD, Neutral current, Max Demand (with RTC),Events (high-low) with time stamp, Individual Harmonics upto 31st, Meter with Ethernet port - 3 Sets Supply, erection, testing & commissioning of PLC based AMF cum load sharing system for 2 Nos DG set, including necessary SMPS, AUX contactor or Relay, DIN Rail, Selector Switch, Push Button, Terminal, Indication lamp, Legs, End plate, Stopper, 1.5 Ferule, Screw, Neutral link, 2.5 Sqmm wire, 1.5 Sqmm wire, Cable tie, Tie mount and all other accessories and components as required for complete installation and as instructed by engineer in charge/consultant.RYB phase indicating LED lamps with control fuses and switches - 3 set;Class B &; Class C/ Class 1 & Class 2 Surge arrestor device with necessary HRC Fuse as back-up protection - 2 Nos.630A, FP, 36 kA Thermal Magnetic Based MCCB as Buscoupler - 1 Not;Outgoings320A 36kA TP+NL Microprocessor Based MCCB - 3 Nos;250A 36kA TP+NL Microprocessor Based MCCB - 1 No200A 36kA TP+NL Microprocessor Based MCCB - 2 Nos;63A 36kA TP+NL Microprocessor Based MCCB - 1 No320 A TP+NL Isolator - 1 No Supply, Installation, testing and commissioning

1

-

-

... More
Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV common Service panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable; Incomer - 1250A, 50kA, EDO, FP Microprocessor Based ACB - 1 No.<br>1250A 433V, 36kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc. complete as required with necessary interlocking arrangement;Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.;Outgoingst;800A, 50kA, EDO, TP+NL Microprocessor Based ACB - 1 Not;630A 36kA TP+NL Thermal Magnetic Based MCCB - 3 Nos.t;Supply, Installation, testing and commissioning

1

-

-

... More
COMMON SERVICE PANEL Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV common Service panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br>Incomer - 200A FP MCCB Isolator - 1 Not;200A 433V, 36kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc. complete as required with necessary interlocking arrangemen;Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAht;RYB phase indicating LED lamps with control fuses and switches - 1 se;Outgoings<br>125A 25kA TP+NL Thermal Magnetic Based MCCB - 1 No.t;100A 25kA TP+NL Thermal Magnetic Based MCCB - 1 No80A 25kA TP+NL Thermal Magnetic Based MCCB - 3 Nos.;32A 25kA TP+NL Thermal Magnetic Based MCCB - 1 No; Supply, Installation, testing and commissioning

1

-

-

... More
LIFT PANEL 1 &2 TYPICAL; Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted/wall mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br> This panel should include pluggable type surge arrester in suitable enclosure Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth, Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc. complete with back up fuse as required and as directed.<br>Incomer - 80A, FP MCCB Isolator - 1No.<br>80A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. <br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1Set,Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No;RYB phase indicating LED lamps with control fuses and switches - 1 setOutgoing<br>63A, FP, 300 mA, RCBO - 1 No;25A, DP, 30 mA, RCBO - 1 N;25A, 415V, 16 kA best conductivity Al DP bus bar with SMC supports, heat shrinkable sleeves etc. complete as required - 2 Set<br>16A, DP, MCB - 2 Nos6A, DP, MCB - 2 Nos.;Supply, Installation, testing and commissioning

2

-

-

... More
PLUMBING PANEL<br>Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable; Incomer - 100A FP MCCB Isolator - 1 No.<br>100A, 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh<br>RYB phase indicating LED lamps with control fuses and switches - 1 se;Outgoings50A 16kA TP+NL Thermal Magnetic Based MCCB - 2 Nos.<br>25A 16kA TP+NL Thermal Magnetic Based MCCB - 1 No16A 16kA TP+NL Thermal Magnetic Based MCCB - 1 No10A TP+NL MCB - 3 Nos;Supply, Installation, testing and commissioning

1

-

-

... More
UPS PANEL Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable Incomer - 63A FP MCCB Isolator - 1 No.<br>63A, 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement;Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAht;RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoing;40A 16kA TP+NL Thermal Magnetic Based MCCB - 2 Nos.<br>32A 16kA TP+NL Thermal Magnetic Based MCCB - 2 Nos;Supply, Installation, testing and commissioning

1

-

-

... More
MEDICAL GAS SM DB;Supply, erection, testing and commissioning of wall mounting type, double door 3 phase 6 way Load Bank of approved make IP43 and quality with cable end box, meter module including busbar, neutral link and DIN bar with all accessories etc. complete with all connections and inter-connections as shown in the schematic drawing, Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge / consultant.<br>This panel should include pluggable type surge arrester in suitable enclosure Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc. complete with back up fuse as required and as directed.<br>Incomer - 125 A FP 25kA thermal magnetic release MCCB - 1No.<br>125A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. <br>Prewired meter module including all meters and indicating lamps - 1 Set<br>Cable alley - 2 Set<br>Class B+C / Class 1+2 Surge arrestor device with enclosure & necessary MCCB for protection of same - 1 No.<br>Outgoings;40A 16kA TP+NL MCCB, with thermal magnetic release - 2 Nos.;32A 16kA TP+NL MCCB, with thermal magnetic release - 4 Nos.<br>Supply, Installation, testing and commissioning

1

-

-

... More
LOAD BANK - 1F + 2F<br>Supply, erection, testing and commissioning of wall mounting type, double door 3 phase 8 way Load Bank of approved make IP43 and quality with cable end box, meter module including busbar, neutral link and DIN bar with all accessories etc. complete with all connections and inter-connections as shown in the schematic drawing, Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant.<br>This panel should include pluggable type surge arrester in suitable enclosure Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350µ sec) for Line to Neutral &25 kA(10/350µ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc. complete with back up fuse as required and as directed.;Incomer - 125 A FP 25kA thermal magnetic release MCCB - 1No.<br>125A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. ;Prewired meter module including all meters and indicating lamps - 1 Set<br>Cable alley - 2 Set;Class B+C / Class 1+2 Surge arrestor device with enclosure & necessary MCCB for protection of same - 1 No.&Outgoings&;50A/63A 16kA TP+NL MCCB, with thermal magnetic release - 3 Nos.40A 16kA TP+NL MCCB, with thermal magnetic release - 3 Nos.<br>25A 16kA TP+NL MCCB, with thermal magnetic release - 2 Nos.<br>Supply, Installation, testing and commissioning

1

-

-

... More
SH 4 - ELV WORKS - DATA

-

-

-

... More
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT6 Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

29

-

-

... More
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT 6A Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

2

-

-

... More
CAT6 Cable - Supplying and drawing of Category 6 cable consists of 4 pairs of solid insulated copper 23AWG, surface/ recessed medium class PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

904

-

-

... More
CAT 6A Cable - Supplying and drawing of Category 6A cable consists of 4 pairs of solid insulated copper 23AWG, surface/ recessed medium class PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

62

-

-

... More
OFC Cable - Supplying and drawing of 6 core SM armoured Optical Fibre Cable (OFC) through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

19

-

-

... More
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 2 Meter length etc. of approved make as required for complete installation.

29

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 1 Meter of approved make as required for complete installation.

29

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of Fibre Patch Cable - 2 Meter of approved make as required for complete installation.

3

-

-

... More
VOICE

-

-

-

... More
Information Outlet RJ 11 - Supply, fixing, testing and commissioning of RJ11 Information Outlets (Key stone) with shuttered Faceplate, single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

21

-

-

... More
Cable - Supplying and drawing of following pair telephone cable consists of 0.5 mm dia FR, PVC Compound annealed copper conductor, unarmoured telephone cable in surface / recessed medium class FRS PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 2 Pair Telephone Cable

678

-

-

... More
Cable - Supplying and laying of following pair armoured telephone cable through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 10 Pair Telephone Cable

16

-

-

... More
Cable - Supplying and laying of following pair armoured telephone cable through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation 20 Pair Telephone Cable

10

-

-

... More
krone Box - Supply, erection, testing and commissioning of following pair krone Box with mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 10 pair

1

-

-

... More
Krone Box - Supply, erection, testing and commissioning of following pair krone Box with mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 20 pair

1

-

-

... More
Krone Box - Supply, erection, testing and commissioning of following pair krone Box with mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 50 pair MDF Krone

1

-

-

... More
Supply, Installation, Testing and Commissioning of PBX with 30 Analog extensions expandable up to 50 with maximum of 10 concurrent calls, 1 PRI interface, Failover Function, Web Interface, Call Dashboard, DISA, IVR, Call Hunt etc. including two numbers master console phone &short key / Direct Station Selection (DSS) Console Built-In Auto Answer TDM/IP Coverage ISDN Compatibility Voice Mail Integration Paging Announcement Programmable Function Keys Call Waiting

1

-

-

... More
Supply, installation, testing and commissioning of Basic user phone with necessary connection as required for complete installation as directed by the engineer in charge.

21

-

-

... More
Surge Protection Device For EPABX: Supply, Installation, Testing and commissioning of SPD with enclosure, the surge protection device shall be suitable to protect telephone lines designed to with stand both lightning current and switching surges. Technology: GD tube, Nominal Voltage: 180 V, Pulsed Current (10/350 µs ) Iimp: 1 KA, Nominal Discharge Current (8/20 µs )/phase In: 5KA, Maximum discharge current: 10 KA,Voltage Protection Level(sym)700V,Response time1n secbr

1

-

-

... More
CLOSED CIRCUIT TELEVISION (CCTV)

-

-

-

... More
Camera for General Area - Dome - Supply, Installation, testing and commissioning of IP based 3.6 mm fixed lens, 2MP resolution, H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge.

13

-

-

... More
Camera for Lift - Dome - Supply, Installation, testing and commissioning of IP based 2.8 mm fixed lens, 2MP resolution, H.264 / H.265, 1/2.8.Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet)<br>

2

-

-

... More
Camera for Corridor - Dome - Supply, Installation, testing and commissioning of IP based 2.8/3.6 mm to 9/12 mm varifocal lens, 2MP resolution, H.264 / H.265, 1/2.8.Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet)

8

-

-

... More
Camera - Bullet - Supply, Installation, testing and commissioning of Varifocal Bullet Camera with 2 MP, H.264 / H.265, built-in IR LED, 2.8/3.6 mm to 9/12 mm, 20 to 30 meters IR range, IP 66 with all connectors and necessary accessories for mounting in false ceiling/True Ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet)

4

-

-

... More
Network Video Recorder with Storage: Supply, installation, testing and commissioning of Channel Network Video Recorder with Recording Storage space server for 30 days, Supports 64 channels 720 P resolution video recording at real time, NVR ONVIF supporting, Recording resolution of Max 4 MP, should support dual video HDMI output, H.265,H.264 at real time. Video storage expansion for recording for complete installation with all accessories as required and directed by engineer in charge. (Consider the sufficient HDDs for 720p @ 20 FPS for 30 days continues recording for all channels). Storage calculation details shall be submitted.

1

-

-

... More
LED Display - Supply, installation, testing and commissioning of 43 inch full HD LED display for video wall arrangement for 24 x 7 Setup including necessary connection, HDMI cable, rating tray etc. as required for complete installation with all accessories as required and directed by engineer in charge.

1

-

-

... More
CAT6 Cable - Supplying and drawing of Category 6 cable consists of 4 pairs of solid insulated copper 23AWG, surface/ recessed medium class PVC conduit through wall/tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

624

-

-

... More
Supply, installation, testing and commissioning of workstation with Intel I5 or above, 4 GB ram and 1 TB HDD with software for CCTV integration

1

-

-

... More
PUBLIC ADDRESSING SYSTEM (PAS)

-

-

-

... More
Ceiling Mounted Speaker - Supply, fixing, testing and commissioning of ceiling mount Metal Grille Speakers with inbuilt line matching transformer with power 6W with required accessories for installation as required.

63

-

-

... More
Wall Mounted Speaker - Supply, fixing, testing and commissioning of Cabinet Speakers with inbuilt line matching transformer with power 12W with a volume controller to adjust the volume individually as per the requirement with all accessories for complete installation as required. The volume controller shall be fixed separately as per the site condition for individual control. Cost inclusive of necessary interconnection including conduit, connection wire etc required for complete installation.

32

-

-

... More
Mixing Amplifier - Supply, fixing, testing and commissioning of 240 Watts Mixer Amplifier with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.

1

-

-

... More
Power Amplifier - Supply, fixing, testing and commissioning of Power Amplifier of 480 Watts with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.

2

-

-

... More
Controller - Supply, fixing, testing and commissioning of Master zone controller with routing zone capacity of additional 6 zones with all accessories and necessary connections including necessary cables and jacks as required for complete installation. The work also include integration with Fire Alarm System (FAS) including to play the pre-recorded message in case of fire and evacuation.

1

-

-

... More
Call Stations - Supply, fixing, testing and commissioning of 6 Zone Calling Station with mic as per the drawing as required for complete installation.

1

-

-

... More
Audio/Video player - Supply, installation, testing &commissioning of Audio/Video player with USB option with all accessories like jacks and codes for complete installation as required as directed by the Engineer in charge.

1

-

-

... More
Speaker Cable - Supplying and drawing of 2 Core, Twin Twisted, ATC tinned copper, overall sheathed, Armoured Speaker cable, 16 AWG for speakers through surface / Tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

1627

-

-

... More
ACTIVE COMPONENTS, RACKS ACCESSORIES

-

-

-

... More
Supply, Installation, Testing and installation of Cat - 6, shuttered type, 24 port fully loaded patch panel with necessary cable manager for routing the cable inside rack with all accessories required for complete installation as required as directed by the engineer in charge.

3

-

-

... More
Supply, Installation, Testing and installation of Cat - 6, 24 port 10/100/1000 Mbps, layer 2, POE, switch with rack mounting brackets, input connector shall be as per IEC-320-C14 with all accessories required for complete installation populated with 1G single SFP module for uplink as required as directed by the engineer in charge. The switch should be capable to provide sufficient power budget to IP cameras as per the requirement.

3

-

-

... More
Supply, installation, testing and commissioing of 6U Rack with Front glass door, Rear Perforated door with handle Lock & key. Front/Rear 6U mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan with all accessories required for complete installation as directed by the engineer in charge.

1

-

-

... More
Supply, installation, testing and commissioing of 4U Rack with Front glass door, Rear Perforated door with handle Lock &key. Front/Rear 4U mounting angles, top, bottom open, RAL 9005, including necesary exhaust/circulation fan with all accessories required for complete installation as directed by the engineer in charge.

1

-

-

... More
Supply, Installation, Testing and installation of Cat - 6, 12 port Layer 3 Managable Core switch with rack mounting brackets, input connector shall be as per IEC-320-C14 with all accessories required for complete installation populated with 1G single SFP module as required as directed by the engineer in charge.

1

-

-

... More
Supply, Installation, Testing and installation of 6 port Light Interface Unit (LIU) / Fibre Patch Panel, rack mountable with mounting brackets, loaded with Adapetors, Couplers Single Mode (SM) pigtails with splicing with all accessories required for complete installation as required as directed by the engineer in charge.

2

-

-

... More
Supply, installation, testing and commissioning of 12U Rack with Front glass door, Rear Perforated door with handle Lock &key. Front/Rear 12U mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan with all other accessories required for complete installation as directed by the engineer in charge.

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections including tees, bends, cross sections etc required for complete installation as per the requirement joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts & nuts, etc. as required for complete installation as directed by the engineer in charge. (For Data, Voice, CCTV &PA) 100 mm width X 50 mm depth X 1.6 mm thickness.

132

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections including tees, bends, cross sections etc required for complete installation as per the requirement joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts &nuts, etc. as required for complete installation as directed by the engineer in charge. (For Data, Voice, CCTV & PA) 150 mm width X 50 mm depth X 1.6 mm thickness

264

-

-

... More
SH - 6 - MGPS - OXYGEN SYSTEM

-

-

-

... More
Supply, Installation, Testing and Commissioning of Oxygen Manifold - 2 banks x 5 cylinders, as per technical specifications (also meeting ISO 10524-2, ISO 7396-1:2016/ISO, 7396-2/HTM02-01). The cylinders shall not be included in the quoted price.

1

-

-

... More
Supply, Installation, testing and commissioning of Fully Automatic Oxygen Control Panel with minimum flow rate of 500 LPM, BMS compatible; as per technical specifications (also meeting ISO 10524-2, ISO 7396-1:2016/ISO, 7396-2/HTM02-01).

1

-

-

... More
Supply, Installation, testing and commissioning of Emergency Oxygen Manifold - 2 banks x 2cylinders, as per technical specifications (also meeting ISO 10524-2, ISO 7396-1:2016/ISO, 7396-2/HTM02-01). The cylinders shall not be included in the quoted price.

1

-

-

... More
Oxygen Flowmeters with humidifier bottle

60

-

-

... More
MEDICAL AIR SYSTEM

-

-

-

... More
Compressed air plant complete with - 2 screw compressors, compressor should have minimum free air delivery of 500 LPM and 1 screw compressors should have minimum free air delivery of 500 LPM, 2 air receiver, medical air duplex drier system (heatless type) with air purification system to ensure medical air quality as per European Pharmacopeia, pressure reducing station, control panel, automatic drain valves, ball valves etc. and as per technical specifications. 1 air receiver Tank capacity 500 Ltr

1

-

-

... More
VACCUM PLANT SYSTEM

-

-

-

... More
Vacuum plant complete with 2 reciprocating type vacuum pumps, each vacuum pump should have minimum free air aspirated of 500 LPM at 450 mmHg, 1 vacuum receiver 500 litre, secretion trap, bacteria double filter, control panel, ball valves etc. ( ISO 10524-2, ISO 7396-1:2016/ISO, 7396-2/HTM02-01).

1

-

-

... More
Ward Vacuum Units

60

-

-

... More
ICU TERMINAL UNITS-IMPORTED

-

-

-

... More
SITC of ICU Terminal Units - Imported - VAC

32

-

-

... More
SITC of ICU Terminal Units - Imported - Air

16

-

-

... More
SITC of ICU Terminal Units - Imported - O2

32

-

-

... More
WARD TERMINAL UNITS-INDEGENOUS

-

-

-

... More
WARD Terminal Units - Indigenous Terminal Unit Vac

44

-

-

... More
SITC of Ward Terminal Units - Indigenous - Air

20

-

-

... More
SITC of Ward Terminal Units - Indigenous - O2

44

-

-

... More
Matching Probe Air

16

-

-

... More
Supply, Installation, testing and commissioning of Matching Probe-Meets the requirements of ISO 9170-1 With one end suitable for Hose & other end suitable for terminal units as per technical specifications as per enclosed specifications. PROB FOR ICU Terminal Units Matching Probe O2

32

-

-

... More
Matching Probe VAC

32

-

-

... More
PROB FOR WARD Terminal Units Matching Probe O2

44

-

-

... More
Matching Probe Air

20

-

-

... More
Matching Probe VAC

44

-

-

... More
Supply, Installation, testing and commissioning of Plant Alarm Panel, BMS compatible, as per technical specifications

1

-

-

... More
Supply, Installation, testing and commissioning of Area alarm + Area valves +Gauges - Area alarm and shut-off unit for medical gases must be acc. To ISO 10524-2, ISO 7396-1:2016/ISO, 7396-2/HTM02-01. Area alarm and area valves should be in a single unit or Equivalent. 4 Services 2 O2,1 M Air and 1 Vac

2

-

-

... More
Supply, Installation, testing and commissioning of Area alarm + Area valves +Gauges - Area alarm and shut-off unit for medical gases must be acc. To ISO 10524-2, ISO 7396-1:2016/ISO, 7396-2/HTM02-01. Area alarm and area valves should be in a single unit or Equivalent. 3 Services 1 O2,1 M Air and 1 Vac

1

-

-

... More
Supply, Installation, testing and commissioning of Area alarm + Area valves +Gauges - Area alarm and shut-off unit for medical gases must be acc. To ISO 10524-2, ISO 7396-1:2016/ISO, 7396-2/HTM02-01. Area alarm and area valves should be in a single unit or Equivalent. 2 Services 1 O2 and 1 Vac

2

-

-

... More
Supply, Installation, testing and commissioning of Copper pipe: Per Mtr (meeting HTM 02-01 or equivalent national standards) 12mm

517

-

-

... More
Supply, Installation, testing and commissioning of Copper pipe: Per Mtr (meeting HTM 02-01 or equivalent national standards) 15mm

239

-

-

... More
Supply, Installation, testing and commissioning of Copper pipe: Per Mtr (meeting HTM 02-01 or equivalent national standards) 22mm

444

-

-

... More
Supply, Installation, testing and commissioning of Copper pipe: Per Mtr (meeting HTM 02-01 or equivalent national standards) 28mm

92

-

-

... More
Supply, Installation, testing and commissioning of Copper pipe: Per Mtr (meeting HTM 02-01 or equivalent national standards) 35mm

103

-

-

... More
Supply, Installation, testing and commissioning of Copper pipe: Per Mtr (meeting HTM 02-01 or equivalent national standards) 42mm

44

-

-

... More
Supply, Installation, testing and commissioning of Ball Valves (HTM 02-01 and other relevant internation standards.) 22mm

3

-

-

... More
Supply, Installation, testing and commissioning of Ball Valves (HTM 02-01 and other relevant internation standards.) 28mm

7

-

-

... More
Supply, Installation, testing and commissioning of Ball Valves (HTM 02-01 and other relevant internation standards.) 35mm

2

-

-

... More
Supply, Installation, testing and commissioning of Ball Valves (HTM 02-01 and other relevant internation standards.) 42mm

1

-

-

... More
BED HEAD PANELS

-

-

-

... More
Supply,Installation,testing and commissioning of Bed head Units of length 1000mm for wards with Terminal unit provisions as per tender specification, Provision for Electrical and data points as per tender specification. Accessories including suction holder and one monitor holder with fall protection and one basket for ECG leads cable holder

44

-

-

... More
Supply,Installation,testing and commissioning of Bed head Units of length 1500mm for ICU Category with Terminal unit provisions as per tender specification, Provision for Electrical and data points as per tender specification. Accessories including suction holder and one monitor holder with fall protection and one basket for ECG leads cable holder.

16

-

-

... More
SH - 5 - HVAC WORKS - Split units

-

-

-

... More
Supply, Installation, testing and commissioning of inverter type split air cooled Air-conditioners each complete with rotary/scroll compressor, air cooled condensor, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro- processor control panel for each machine. Rate quoted shall include GI painted frame works for outdoor units, all associted works &making good of civil work. Refrigerant shall be R410A / R32. Price shall inclusive of all taxes &duties, installation, commissioning, Refrigerant piping as per Drawing. 1 TR Hiwall Split unit

2

-

-

... More
Supply, Installation, testing and commissioning of inverter type split air cooled Air-conditioners each complete with rotary/scroll compressor, air cooled condensor, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro- processor control panel for each machine. Rate quoted shall include GI painted frame works for outdoor units, all associted works & making good of civil works. Refrigerant shall be R410A / R32. Price shall inclusive of all taxes &duties, installation, commissioning, Refrigerant piping as per Drawing. 1 TR One way cassette Split unit

4

-

-

... More
Supply, Installation, testing and commissioning of inverter type split air cooled Air-conditioners each complete with rotary/scroll compressor, air cooled condensor, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro- processor control panel for each machine. Rate quoted shall include GI painted frame works for outdoor units, all associted works & making good of civil works. Refrigerant shall be R410A / R32. Price shall inclusive of all taxes & duties, installation, commissioning, Refrigerant piping as per Drawing. 2 TR Hiwall Split unit

2

-

-

... More
DOUBLE SKIN AIR HANDLING UNITS WITH DX COILS,VFD AND PLUG FANS

-

-

-

... More
Supply, Installation, testing &commissioning the AHUs as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated, Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessory Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq.cage induction motor of required rating including mounting and fixing arrangements Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Insulation of Drain pan as per specifications. Insulated drain piping with trap till the out let of the AHU. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Thermostat, duct damper, including Control wiring, cordless remotes, refnet joints, control cabling between indoor/AHU & out door units, AHU Kit, communication cables etc. Limit switch in door and inspection lamps to be fixed. Lockable on/off push button including necessary control connections to be provided near AHU. Fine filter efficiency 99.9% down to 5 micron AHU static pressure = 55 mm wc Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc good as same. 7 TR, 3200 Cfm, 6.4 Sq.ft/6 Row Double skin ceiling suspended AHU with DX coil, fine filter, Mixing Box, VFD Drive Plug fans

1

-

-

... More
Supply, Installation, testing & commissioning the AHUs as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. Pre-Plasticised Sheet/ powder coated, Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessory Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq.cage induction motor of required rating including mounting and fixing arrangements Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Insulation of Drain pan as per specifications. Insulated drain piping with trap till the out let of the AHU. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Thermostat, duct damper, including Control wiring, cordless remotes, refnet joints, control cabling between indoor/AHU &out door units, AHU Kit, communication cables etc. Limit switch in door and inspection lamps to be fixed. Lockable on/off push button including necessary control connections to be provided near AHU. Fine filter efficiency 99.9% down to 5 micron. AHU static pressure = 55 mm wc Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc good as same. 9 TR, 3600 Cfm, 7.2 Sq.ft/6 Row Double skin ceiling suspended AHU with DX coil, fine filter, Mixing Box, VFD Drive Plug fans

3

-

-

... More
CONDENSING UNIT(OUTDOOR UNIT)

-

-

-

... More
Supply, Installation, testing &commissioning of Air-cooled condensing unit complete with scroll/rotary compressor consist of microprocessor based control panel, sufficient refrigerant (R-410), vibration isolator etc. Condensing unit of minimum 7 TR capacity

1

-

-

... More
Supply, Installation, testing & commissioning of Air-cooled condensing unit complete with scroll/rotary compressor consist of microprocessor based control panel, sufficient refrigerant (R-410), vibration isolator etc. Condensing unit of minimum 9 TR capacity.

3

-

-

... More
PIPING

-

-

-

... More
Liquid line - Refrigerant piping with 19 mm thick nitrile rubber insulation and with glass cloth &foaster painting.

64

-

-

... More
Suction line - Refrigerant piping with 19 mm thick nitrile rubber insulation and with glass cloth & foaster painting.

64

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water &AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 25 mm Dia PVC

60

-

-

... More
SHEET METAL WORK

-

-

-

... More
Supply, fabricate, handle and erect factory fabricated GSS ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces slip on flanges etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs. wall opening as good as same. 0.63mm GSS ducting in sq.m.

220

-

-

... More
Supply, fabricate, handle and erect factory fabricated GSS ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces slip on flanges etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs. wall opening as good as same 0.80mm GSS ducting in sq.m.

70

-

-

... More
GRILLS AND DIFFUSERS

-

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 375x375

43.2

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 RD: 375 x 375

45

-

-

... More
Supply, Fabrication, installation and testing of 250 mm dia insulated semi flexible ducting, complete with connecting rings, duct supports etc as per standards and specification.

65

-

-

... More
Insulated Plenum Box made of 22G G.I &Spigot &Butterfly Dampers with necessary threaded rods for supporting for the following sizes 400X400X400H

43.2

-

-

... More
SITC of Factory made fresh air dampers with louvers and control lever, filter etc as required. (as per drawing)

4

-

-

... More
Supply, fix, balance, and commission louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, fixing arrangement etc.complete brass bushings

1.2

-

-

... More
Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link microswitch to shut of corresponding Unit (including control cable.)

1

-

-

... More
DUCT INSULATION AND LINING

-

-

-

... More
Thermal insulation: Supply &fixing of 8 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3

280

-

-

... More
Acoustic insulation: Supply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140-180kg/m3

55

-

-

... More
Under Deck Insulation - For ICU: Supply &fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3

2800

-

-

... More
Exposed roof insulation Supply &fixing of 12 mm thick class o nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3 for terrace floor.

2325

-

-

... More
VENTILATION SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 80 CFM

1

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 350 CFM

1

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 450 CFM

1

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 500 CFM

1

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 680 CFM

2

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 800 CFM

1

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 850 CFM

1

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and louvers with bird screen and flexible connection to connect with ducting / plenum. 200 CFM

1

-

-

... More
SHEET METAL WORK Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63mm Sheet

70

-

-

... More
Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification. Size: 100 mm dia

54

-

-

... More
GRILLES & DIFFUSERS Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers of design to be approved (material : Al) Return air grille/diffuser with vcd

1

-

-

... More
SH - 7 - PASSENGER CUM BED LIFT

-

-

-

... More
26 Passenger cum Bed Lifts LIFT-1 &2: Design, manufacture, supply, installation at site, testing, commissioning and maintain Passenger cum Bed Lift to carry 26 (Twenty Six) persons capacity of load 1768 Kgs with a minimum speed of 1.5 metre per second as per the detailed specification attached including all necessary safety features and in accordance with theparticulars of lift service requirement and technical specifications etc. complete.6 Stops and 6 openings. (Shaft Size available - 3000 mm x 2500 mm) Note :The rate shall include obtaining necessary initial and final approval from Kerala State electrical Inspectorate for lift installation and operation before handing over the entire lift installation.

2

-

-

... More
SH - 8 - FIRE PUMPS AND ACCESSORIES

-

-

-

... More
MAIN PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Hydrant Pump Set: Electrical Driven, Capacity: 2280 LPM at 70 Meter Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, High Efficient IE-3 rated, Squirrel Cage Induction Electric Motor, Suitable HP, 3Ph, 50 Hz, 2900/3000 RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and necessary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

1

-

-

... More
SPRINKLER PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Sprinkler Pump Set: Electrical Driven, Capacity: 2280 LPM at 70 Meter Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, High Efficient IE-3 rated, Squirrel Cage Induction Electric Motor, Suitable HP, 3Ph, 50 Hz, 2900/3000 RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and necessary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

1

-

-

... More
JOCKEY PUMP - Supply, installation, testing and commissioning of Jockey Pump: Electrical Driven, Capacity: 180 LPM at 75 Mtrs. Head, Vertical Multi Stage Inline Pump with S.S Impeller, Mechanical Seal, and with High Efficient IE-3 Rated Squirrel Gauge Induction Motor, Suitable HP, 3Ph, 50 Hz, 3000 RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and necessary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

2

-

-

... More
DIESEL PUMP - Supply, installation, testing and commissioning of Stand By / Back Up Fire Pump, Horizontal long coupled, End Suction Pump, Engine Driven, suitable for Automatic operation and consisting of the following and complete in all respect as required; Capacity: 2280 LPM at 70 Meter Head conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, coupled to High Efficient Radiator Cooled Diesel Engine, Suitable HP, 2150 RPM, and with Control Panel with Auto Starting Facility, by activation of concerned Pressure Switch and thro. 12V/24 V Electric Starter, Battery of adequate rating and with Battery Charger, Battery Leads, Diesel Tank for 6 hrs operation, exhaust pipe extended up to 1 mtr outside pump house, duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, complete with necessary civil foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, and all other necessary fixing accessories, all as per Technical Specifications.

1

-

-

... More
Supply, erection, commissioning of additional length of Exhaust Pipes with long radius bend from silencer with necessary clamps, fixtures, civil works and thermal insulation with 50 mm thick glass wool and with 1.0 mm thick aluminium sheet cladding of following adequate size including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. The horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc. as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust.

35

-

-

... More
MOTOR CONTROL PANEL - Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated Common Control Panels for Main Fire Pumps &Jockey Pumps, made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates (top entry) made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. The panel shall be IP: 54 protection, complete with Main Isolator, Bus Bar Chamber, Volt Meter, Ammeter, Individual Star- Dealt Starters for Main Pumps, DOL Starter for Jockey Pump, Contactors, Auxiliary Contacts, Timers for automatic operation and to avoid frequent re-starts, Indicating Lamps, Fuses, Auto / Manual Selector Switches for all Fire Pumps, Manual On / Off Buttons for Jockey Pump &Manual On Buttons for Main Pumps, all internal wiring etc. The price for Control Panel shall be inclusive of, Control Cabling, in Steel Conduits, for automatic starting of Main Pumps &Automatic start and stop for Jockey Pump and Earthing of the Panel, all as per Technical Specifications, Schematic Drawing, Prevailing Rules, Standards, Requirement and Site Conditions. The Panel shall be to the approval of Kerala State Electrical Inspectorate. Main Fire Pump - 1 No.Sprinkler Pump - 1 No.Jockey Pump - 2 Nos.Incomer - 320A, FP, MCCB Isolator - 1No.320A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh Class B + C / Class 1 + 2 Surge arrestor device with necessary MCCB for protection of same - 1Set. RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoing 125A, TP+NL, MCCB Isolator + Star delta starter with all accessories Without overload relays / protection - 2 Set. 32A, TP+NL, MCCB Isolator + DOL Starter with all accessories with overload really and single phase preventer - 2 Set. Supply, Installation, Testing &Commissioning

1

-

-

... More
Supply, installation, testing and commissioning of Pressure Switches with pressure rating suitable for Fire Pumps, with a differential of 0.2 to 1.6 Bar, as per Technical Specifications.

6

-

-

... More
Supply, installation, testing and commissioning of Diaphragm Pressure Vessel, 112 Ltrs Capacity, 15 Bar Working Pressure at a maximum flow rate of 2280 LPM. The vessel shall be with replaceable interior air cell, metallic outer shell, base, air release valve etc., all as per Technical Specifications.

1

-

-

... More
FIRE HOSE REEL AND HYDRANT SYSTEMS

-

-

-

... More
Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided / rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm. isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set.

9

-

-

... More
Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark, Stainless Steel-304 body with 63mm. oblique instantaneous single outlet, 75mm. N.B. flanged inlet, Stainless Steel -304 spindle, complete with PVC blank cap, G.I. chain etc.

14

-

-

... More
Supply, installation, testing and commissioning of Fire Brigade Inlet Breeching, C.I. body, having 3 Gunmetal, 63mm. male instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 3 nos. of rubber blank caps and G.I. chains.

1

-

-

... More
Supply, installation, testing and commissioning of Fire Brigade Draw Off Outlet C.I. body, having 3 Gunmetal, 63mm. female instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 3 nos. of rubber blank caps and G.I. chains.

1

-

-

... More
Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fibre. conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg / Cm2 and Burst Pressure 38 Kg / Cm2. The Fire Hose shall be with IS: 636 Type-A marking and 63mm. dia. x 15 Meter long with pair of 63mm. male and female instantaneous couplings, Stainless steel - 304, having IS: 903 mark and duly S. S. wire wounded. The hose shall be rolled and hung to suitable M. S. support in the Fire Station.

28

-

-

... More
Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark.

14

-

-

... More
Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30"x 24"x 10"size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement.

9

-

-

... More
Supply and fix at site in position Weather Proof Fire Hose Cabinet, wall / pole mounting type, 30" x 24" x 10"size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and pole for mounting, all as per requirement.

5

-

-

... More
AUTOMATIC FIRE SPRINKLER SYSTEM

-

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage, Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings. Upright Type, 68 Degree C Rating.

133

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage, Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings Pendant Type, 68 Degree C Rating.

260

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage, Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings. Pendant Type, 79 Degree C Rating.

2

-

-

... More
Providing, fixing, testing and commissioning of Extended Coverage, Quick Response Horizontal Side Wall Type Automatic Fire Sprinkler, 68 degree, K- Factor: 5.6 with necessary accessories and fittings. The Fire Sprinklers shall be UL listed.

5

-

-

... More
Providing &Fixing 2 Piece Chrome Plated Friction Fit recessed escutcheon for pendant sprinklers, as per requirement.

260

-

-

... More
Providing, Fixing, Testing and Commission Flexible Sprinkler Hose; UL Listed or FM Approved, 25mm. (1") BSP Male Inlet, 15mm. (1/2") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, length: 1000 mm, and with all connecting systems and accessories.

260

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 20 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System. The control cabling from flow switches to Fire Sprinkler Annunciating Panel shall be measured separately.

9

-

-

... More
FIRE PIPES, VALVES AND ACCESSORIES

-

-

-

... More
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 25mm

498

-

-

... More
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 32mm

82

-

-

... More
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 40mm

164

-

-

... More
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 50 mm.

33

-

-

... More
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 65mm

94

-

-

... More
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 80mm

141

-

-

... More
Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 100mm

74

-

-

... More
Hydrant, Sprinkler System &Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and Galvanized Grooved Fittings, for pipes above 50mm. dia, for pump room But Welded fittings with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 150mm

246

-

-

... More
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8329 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot joint. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer's technical details. i. Internal lining with Cement Mortar ii. External Coating with a layer of metallic zinc + a layer of bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall inclusive of earth work excavation and refilling & compacting of soil after laying the pipe including necessary Masonry / PCC / RCC Thrust Blocks as per requirement. 80 mm.

52

-

-

... More
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8329 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot joint. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer's technical details. i. Internal lining with Cement Mortar ii. External Coating with a layer of metallic zinc + a layer of bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall inclusive of earth work excavation and refilling & compacting of soil after laying the pipe including necessary Masonry / PCC / RCC Thrust Blocks as per requirement. 100 mm.

56

-

-

... More
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8329 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot joint. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer's technical details. i. Internal lining with Cement Mortar ii. External Coating with a layer of metallic zinc + a layer of bitumen coating. iii. Further protection with loose &air / water tight polythene sleeves. The cost for underground pipe work shall inclusive of earth work excavation and refilling &compacting of soil after laying the pipe including necessary Masonry / PCC / RCC Thrust Blocks as per requirement. 150 mm.

80

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. 25 mm.

36

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. 50 mm.

4

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. 80mm.

2

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. 100mm.

6

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. 150mm.

11

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed or FM Approved, with required Matching Flanges, nuts, bolts etc. complete, all as per Technical Specifications. 80mm.

2

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed or FM Approved, with required Matching Flanges, nuts, bolts etc. complete, all as per Technical Specifications. 100mm.

4

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed or FM Approved, with required Matching Flanges, nuts, bolts etc. complete, all as per Technical Specifications. 150mm.

7

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16 or Above, conforming to IS: 5312 part 1 with required companion flanges nuts, bolts etc. complete. 80mm.

2

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16 or Above, conforming to IS: 5312 part 1 with required companion flanges nuts, bolts etc. complete. 100mm.

4

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16 or Above, conforming to IS: 5312 part 1 with required companion flanges nuts, bolts etc. complete. 150mm.

4

-

-

... More
Supply, installation, testing and commissioning of Heavy Duty Neoprene Expansion Joints / Flexible Connectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories. 80mm.

2

-

-

... More
Supply, installation, testing and commissioning of Heavy Duty Neoprene Expansion Joints / Flexible Connectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories. 100mm.

4

-

-

... More
Supply, installation, testing and commissioning of Hydraulically Operated Fire Sprinkler Alarm Valve (Installation Control Valve), Grooved End, UL Listed / FM approved, complete with Constant Pressure Trim Assembly, Water Motor Gong, control valves, pressure switch, pressure gauges etc. including all necessary fixing accessories. 150mm. Size

1

-

-

... More
Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 904, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including necessary accessories and connections.

8

-

-

... More
Providing and fixing C.I. Gate Valve with Non Rising Stem & Cap Top, PN-16, confirming to IS: 14846 with ISI Mark and with required companion flanges, rubber insertions, bolts, nuts, Washers etc. complete. The Price shall be inclusive of 'Fabricated Key' for Operation from Ground Level, as per Technical Specifications. 80mm.

1

-

-

... More
Providing and fixing C. I. Gate Valve with Non Rising Stem &Cap Top, PN-16 or above, confirming to IS: 14846 with ISI Mark and with required companion flanges, rubber insertions, bolts, nuts, washers etc. complete. The Price shall be inclusive of 'Fabricated Key' for Operation the Valve from Ground Level, all as per Technical Specifications. 100mm.

1

-

-

... More
Providing and fixing C. I. Gate Valve with Non Rising Stem & Cap Top, PN-16 or above, confirming to IS: 14846 with ISI Mark and with required companion flanges, rubber insertions, bolts, nuts, washers etc. complete. The Price shall be inclusive of 'Fabricated Key' for Operation the Valve from Ground Level, all as per Technical Specifications. 150mm.

2

-

-

... More
Providing and fixing sight glass assembly of brass body and brass ball with chrome plated, steel handle, PN16 or above, UL Listed/ FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems with grooved end connection ends. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass. 25 mm.

6

-

-

... More
Supply, installation, testing and commissioning of 4"dia. Bourdon Type Pressure Gauge, with ISI Mark or of equivalent International Standards. Weather / Water Proof Type with shut off cock and connection Pipe

2

-

-

... More
Supply, installation, testing and commissioning of 4"dia. Bourdon Type Pressure Gauge, with ISI Mark or of equivalent International Standards. Standard Type for indoor use with shut off cock and connection Pipe

1

-

-

... More
INTELLIGENT ADDRESSABLE FIRE ALARM SYSTEM

-

-

-

... More
Supply, install, test and commission Intelligent Addressable Fire Alarm Control Panel (MCP) as per the technical specification and not limited to having Visual Display Unit (VDU) preferably 640 character LCD display with Battery Back up for 24 hours for normal operation and 1 hours on alarm condition. The control panel, battery charger etc., shall be UL listed approved. The panel shall work in a flash scan protocol and shall be networked together and capable of networking with other compatible panels. The Panel shall have 2 Loop Capacity and shall be expandable up to 10 Loop, all as per Technical Specifications.

1

-

-

... More
Supply, install, test and commission Intelligent Addressable Fire Alarm Monitoring Panel (FAMP) as per the technical specification and not limited to having Visual Display Unit (VDU) preferably 640 character LCD display.

1

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Multi Sensor Detectors (Below Ceiling). The detectors shall have multiple sensitivity (adjustable at site) levels, programmable for timed automatic sensitivity selection complete with Standard Base, junction box and other accessories as required. Detectors shall be UL listed/ FM approved

122

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Multi Sensor Detectors (Above Ceiling). The detectors shall have multiple sensitivity (adjustable at site) levels, programmable for timed automatic sensitivity selection complete with Standard Base, junction box and other accessories as required. Detectors shall be UL listed/ FM Approved

41

-

-

... More
Providing, fixing test and commission Intelligent Addressable Manual Call Station Point with addressable module that monitors and reports contact status, all as per technical Specifications.

32

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Weather/Water Proof/Corrosion Resistant type Intelligent Addressable Manual Call Point having an integrally mounted addressable module that monitors and reports contact status, IP67 rated, complete as per technical specifications.

1

-

-

... More
Providing, fixing, test and commission Conventional Type Horn/Strobe rated at 82 dB @3Mtr. for audible annunciation and 75Candela flashing at 1Hz. for visual indication, complete as per technical specifications.

25

-

-

... More
Providing, fixing, testing and commission Weather/Water Proof/ Corrosion Resistant Conventional Type Horn/Strobe, Rated at 82 dB @3Mtr. for audible annunciation and 75Candela flashing at 1Hz. for visual indication, IP: 66 Rated, complete as per technical specifications.

1

-

-

... More
Providing, fixing, testing and commission Intelligent Addressable Input/Monitor Module, as per specification for interface with Flow Switches, Fire Pumps, Supervisory Switches, Alarm Valve, Water Tank Level etc.

10

-

-

... More
Providing, fixing, testing and commission Intelligent Addressable control / Relay Module, as per specification for interface with Lift Panel, Water Curtain Partition, AHUs, Ventilation System, Smoke Management System, Power Distribution, Public Address System etc.

41

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected, all as per technical specifications. (Quantity shall change as per Manufacturer)

23

-

-

... More
Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armoured Cables with Red Colour / Finish, as per Technical Specifications.

836

-

-

... More
FIRE EXTINGUISHERS

-

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking. CO2 - 2.0 Kg.

12

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking. CO2 - 4.5Kg.

1

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking. ABC Dry Chemical, Store Pressure Type - 2 Kg.

34

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking. ABC Dry Chemical Powder, Store Pressure Type - 4 Kg.

1

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking. Clean Agent HCFC 123, 4.0 Kg.

1

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking. Fire Bucket including Fabricated M. S. Stand (Approx. quantity)

3

-

-

... More
TALK BACK SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning of automatic control console of 8 zones micro process based complete with floor to floor announcing and talk back facilities with the following features and made functional: (a) Feather type key pads to select the zones. (b) Moulded plastic attractive enclosure. (c )Backlight Liquid Crystal Display(LCD) (d) User friendly interactive display. (e) Announcement selector - PH Switch. (f) Listen selector switch. (g) All Call switch to select all zones simultaneously for announcement (h) Zones Call Display On the LCD With Audio Alarm. Panel to be installed in the Fire

1

-

-

... More
Controller Unit with 120 W amplifier, Goose neck type microphone and with the following features: (i) Built in Power supply. (ii) Zone Selector switching Circuit (iii)Terminal blocks to terminate zones wires, amplifier wires etc., (iv) Zone Call processing Circuit etc. and made functional. Panel to be installed in the Fire Control Room.

1

-

-

... More
Supply, installation, testing and commissioning of Public Address speaker with talk back facility 6 Watts with L M T and call switch, made out of powder coated CRCA sheet, wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting.

16

-

-

... More
Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armoured Cables with Red Colour / Finish, as per Technical Specifications.

200

-

-

... More
SIGNAGES

-

-

-

... More
Fire Exit Light - Laser type, with High Glow LED Light, size: 12" x 6" or nearby, Ceiling Mounting type with hanging clamps, on/off switch, Red / Green Colour option, power consumption: 18 Watt or less with all accessories required for complete installation as directed by the engineer inc charge. Power supply should be provided with UPS back-up.

16

-

-

... More
Supply and install in position following Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engineer in charge. Signage Printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE "of 1.25cm. height letters in red with white back ground. The size of the board shall be 25 x 30 Cm. and shall be fixed at the height of 2Mts. from finished floor near Manual Pull Stations.

17

-

-

... More
Supply and install in position following Sign Boards made out of 3mm thick "Opaque"PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engineer in charge. Floor Identification Signage ( ie, GROUND FLOOR, FIRST FLOOR, etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm.

17

-

-

... More
Supply and install in position following Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engineer in charge. Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm.

44

-

-

... More
Supply and install in position following Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engineer in charge. Supply and install in position the Signage "FIRE ORDER"it should contain the matter specified in the technical details on 3mm thick "Opaque"PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2 x 3

8

-

-

... More
EXTERNAL (CIVIL) WORK

-

-

-

... More
Constructing masonry Valve Chamber in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice / gate valve, including all supports for fixing valve, with Heavy Duty C.I. cover and frame, i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. Internal Size: 60 x 60 x 75cm, deep

3

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
FIRE SEALANT for all Shafts - Supply and Fixing of load bearing Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mould resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1 g/l as per LEED 2009. Fire stop installation should be done by trained applicators (HAFSC) and in accordance with manufacturers guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemical anchoring along the length and breadth of the shaft and provide 2 layers of chicken mesh etc. The mortar shall be applied with a minimum thickness of 65 mm &having load bearing capacity of 200kg/sqm. Proper engineering judgement needs to be submitted through the manufacturer. Complete installation report through Software CFS DM shall also be submitted for inspection purpose.

17

-

-

... More
FIRE SEALANT for HVAC / MGPS Shafts - Providing Acrylic Firestop Sealant in gaps between periphery of the ducts to provide minimum 2 hours fire rating when subject to the test conditions of UL 2079 standards. The product shall be age tested as per DafStb guidelines. Sealant should provide sufficient MAF, water and gas tight seal. Sealant shall also provide airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation. Sealant shall carry test certificate for mould resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be UL listed &classified and shall bear the UL or FM approval logo on the packing. Fire stop installation should be done by trained applicator (HAFSC) and in accordance with Hilti guidelines. Applicator needs to provide complete installation report through Software CFS DM for inspection purpose.

15

-

-

... More
FIRE SEALANT for Electrical / ELV / FAS Shafts - Providing High performance intumescent fire stop sealant FS One Max that helps protect combustible penetrations for up to 2 hours fire rating in accordance to UL 1479 (American)standards. Surface burning characteristics according UL 723 (ASTM E84-96). Flame spread index 0 and smoke development index 5. The sound transmission classification for this product according ASTM E 90-99 is 56 (STC Rating). It High is mould and mildew resistant and the performance is Class 0 according ASTM G-21. Movement capability approx. 5% (ISO 11600) and the average volume shrinkage is 24% according ASTM C1241. The sealant shall meets LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 9 g/l. product should also Seismic tested on mechanical performance, smoke and fire-ratings. Fire stop installation should be done by trained applicators (HAFSC) and in accordance with Hilti guidelines. Applicator needs to provide complete installation report through Software CFS DM for inspection purpose.

2

-

-

... More
Length of Puddle Flanges, shown, below are tentative only. The actual lengths may change as per final site conditions. 100mm.dia, 1050mm. Long.

1

-

-

... More
Length of Puddle Flanges, shown, below are tentative only. The actual lengths may change as per final site conditions. 150mm.dia, 700mm. Long.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.