Rural Development And Panchayat Raj Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Development And Panchayat Raj Department - RDPR Tender

Opening Date12 Mar 2020
Closing Date12 Apr 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
CPWD code no. 16.26.9 - Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, direct drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. - 17000 CMH / 10000 CFM - Floor Mounted

1

-

-

... More
CPWD code no. 16.26.11 - Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, direct drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. - 20400 CMH / 12000 CFM - Floor Mounted

1

-

-

... More
Supply, Installation, Testing and commissioning of factory direct floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The AHUs shall be additionally fitted with Fine Filters of 99 % efficiency down to 5 micron particle size, inspection doors for access to the Fine Filters and shall be provided with blowers having total static pressure capacity of 60 mm w.g. UV lamps shall be fitted inside the AHU fan chamber along with safety switch actuated by the AHU access door. - 2040 CMH / 1200 CFM

1

-

-

... More
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, direct drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The AHUs shall be additionally fitted with Fine Filters of 99 % efficiency down to 5 micron particle size, inspection doors for access to the Fine Filters and shall be provided with blowers having total static pressure capacity of 60 mm w.g. UV lamps of the indicated capacities shall be fitted inside the AHU fan chamber along with safety switch actuated by the AHU access door. - 6100 CMH / 3600 CFM / 2 x 30 watts UV lamps - Floor Mounted AHU*

4

-

-

... More
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, direct drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The AHUs shall be additionally fitted with Fine Filters of 99 % efficiency down to 5 micron particle size, inspection doors for access to the Fine Filters and shall be provided with blowers having total static pressure capacity of 60 mm w.g. UV lamps of the indicated capacities shall be fitted inside the AHU fan chamber along with safety switch actuated by the AHU access door. - 6800 CMH / 4000 CFM / 2 x 30 watts UV lamps - Ceiling Suspended AHU

2

-

-

... More
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, direct drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The AHUs shall be additionally fitted with Fine Filters of 99 % efficiency down to 5 micron particle size, inspection doors for access to the Fine Filters and shall be provided with blowers having total static pressure capacity of 60 mm w.g. UV lamps of the indicated capacities shall be fitted inside the AHU fan chamber along with safety switch actuated by the AHU access door. - 10900 CMH / 6400 CFM / 3 x 30 watts UV lamps - Ceiling Suspended AHU

1

-

-

... More
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, direct drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The AHUs shall be additionally fitted with Fine Filters of 99 % efficiency down to 5 micron particle size, inspection doors for access to the Fine Filters and shall be provided with blowers having total static pressure capacity of 60 mm w.g. UV lamps of the indicated capacities shall be fitted inside the AHU fan chamber along with safety switch actuated by the AHU access door. - 13600 CMH / 8000 CFM / 4 x 40 watts UV lamps - Floor Mounted AHU

8

-

-

... More
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, direct drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The AHUs shall be additionally fitted with Fine Filters of 99 % efficiency down to 5 micron particle size, inspection doors for access to the Fine Filters and shall be provided with blowers having total static pressure capacity of 60 mm w.g. UV lamps of the indicated capacities shall be fitted inside the AHU fan chamber along with safety switch actuated by the AHU access door. - 17000 CMH / 10000 CFM / 5 x 30 watts UV lamps - Floor Mounted AHU- * Note: These AHUs shall be fitted with 50 mm thick PUF panels.

1

-

-

... More
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical double decker air handling units made of 50 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 8 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, direct drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The AHUs shall be additionally fitted with Fine Filters of 99 % efficiency down to 5 micron particle size, inspection doors for access to the Fine Filters and and shall be provided with blowers having total static pressure capacity of 100 mm w.g. to cater to the air resistance of the terminal HEPA Filters. 4 x 30 watts UV lamps shall be fitted inside the AHU fan chamber along with safety switch actuated by the AHU access door. The Units shall be additionally fitted wiith dessicant coated Heat Recovery Wheel (HRW) complete with casing, drive motor and drive arrangement and exhaust air blowers with suitable TEFC drive motors and drive package. The supply air blowers and the exhaust air blowers shall be of the same air flow quantity. These Units are for 100% fresh air operation. The HRW shall be designed to transfer 85% of the heat energy from the fresh air to the room exhaust air. The HRW shall be so designed that short-cycling if any, shall be only from the fresh air stream to the exhaust stream and NOT from the exhaust stream to the fresh air stream. Inspection doors shall be provided for service access to the HRW, pre and Fine air filters, supply and exhaust air blowers and the cooling coil. The exhaust blower chamber shall be fitted with 2 x 30 watts UV lamps to irradiate the exhaust air that is being blown to the outside. - 6800 CMH / 4000 CFM - Floor Mounted

2

-

-

... More
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical double decker air handling units made of 50 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 8 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, direct drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The AHUs shall be additionally fitted with Fine Filters of 99 % efficiency down to 5 micron particle size, inspection doors for access to the Fine Filters and and shall be provided with blowers having total static pressure capacity of 100 mm w.g. to cater to the air resistance of the terminal HEPA Filters. 4 x 30 watts UV lamps shall be fitted inside the AHU fan chamber along with safety switch actuated by the AHU access door. The Units shall be additionally fitted wiith dessicant coated Heat Recovery Wheel (HRW) complete with casing, drive motor and drive arrangement and exhaust air blowers with suitable TEFC drive motors and drive package. The supply air blowers and the exhaust air blowers shall be of the same air flow quantity. These Units are for 100% fresh air operation. The HRW shall be designed to transfer 85% of the heat energy from the fresh air to the room exhaust air. The HRW shall be so designed that short-cycling if any, shall be only from the fresh air stream to the exhaust stream and NOT from the exhaust stream to the fresh air stream. Inspection doors shall be provided for service access to the HRW, pre and Fine air filters, supply and exhaust air blowers and the cooling coil. The exhaust blower chamber shall be fitted with 2 x 30 watts UV lamps to irradiate the exhaust air that is being blown to the outside. - 8500 CMH / 5000 CFM - Floor Mounted

1

-

-

... More
Supply, installation, testing and commissioning of HEPA filter Modular Housing of size 8' x 6' x 1.5' ht. for ceiling suspension above the Operating Table in OT. The Housing shall be of extruded aluminium frame and insulated panels with 40 mm thick PUF and thermal break arrangement similar to AHU Housing. Complete as per specification.

3

-

-

... More
Supply, installation, testing and commissioning of HEPA filters with aluminium casing, having an efficiency of 99.97% down to 0.3 microns particle size complete as per specifications. The Filters shall be provided with flanges for fixing in the Housing indicated in the item above. Face area of each filter shall be 0.36 sq mts (size 600 mm x 600 mm) and the air flow capacity of each filter will be 500 CFM at 125 fpm face velocity.

33

-

-

... More
Supply, installation, testing and commissioning of High Wall Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity Brushless DC motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings, cordless remote control handset with On/Off switch, thermostat and three speed fan switch, 2 x 15 watts UV-C light for germicidal irradiation and FCU mounting arrangement complete as per specifications. Capacities of the FCUs: - 1.0 TR/400 CFM

3

-

-

... More
Supply, installation, testing and commissioning of High Wall Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity Brushless DC motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings, cordless remote control handset with On/Off switch, thermostat and three speed fan switch, 2 x 15 watts UV-C light for germicidal irradiation and FCU mounting arrangement complete as per specifications. Capacities of the FCUs: - 1.5 TR/600 CFM

29

-

-

... More
Supply, installation, testing and commissioning of High Wall Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity Brushless DC motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings, cordless remote control handset with On/Off switch, thermostat and three speed fan switch, 2 x 15 watts UV-C light for germicidal irradiation and FCU mounting arrangement complete as per specifications. Capacities of the FCUs: - 2 TR/800 CFM

45

-

-

... More
Supply, installation, testing and commissioning of High Wall Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity Brushless DC motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings, cordless remote control handset with On/Off switch, thermostat and three speed fan switch, 2 x 15 watts UV-C light for germicidal irradiation and FCU mounting arrangement complete as per specifications. Capacities of the FCUs: - 2.5 TR/1000 CFM

8

-

-

... More
Supply, installation, testing and commissioning of High Wall Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity Brushless DC motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings, cordless remote control handset with On/Off switch, thermostat and three speed fan switch, 2 x 15 watts UV-C light for germicidal irradiation and FCU mounting arrangement complete as per specifications. Capacities of the FCUs: - 3.0 TR/1150 CFM

1

-

-

... More
Supply, installation, testing and commissioning of Floor Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity blower motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings,with On/Off switch, thermostat and three speed fan switch controls, complete as per specifications. Capacities of the FCUs: - 1.0 TR/400 CFM

2

-

-

... More
Supply, installation, testing and commissioning of Floor Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity blower motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings,with On/Off switch, thermostat and three speed fan switch controls, complete as per specifications. Capacities of the FCUs: - 1.5 TR/600 CFM

48

-

-

... More
Supply, installation, testing and commissioning of Floor Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity blower motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings,with On/Off switch, thermostat and three speed fan switch controls, complete as per specifications. Capacities of the FCUs: -2.0 TR/800 CFM

23

-

-

... More
Supply, installation, testing and commissioning of Floor Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity blower motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings,with On/Off switch, thermostat and three speed fan switch controls, complete as per specifications. Capacities of the FCUs: - 2.5 TR/1000 CFM

2

-

-

... More
Supply, installation, testing and commissioning of Floor Mounted type Chilled Water Fan Coil Units, complete with decorative type sheet metal cabinet having a good aesthetic appearance and powder coated finish, centrifugal blower, suitable capacity blower motor, chilled water cooling coil of copper tubes and aluminium fins, SS drain pan with thermal insulation to prevent condensation and HDPE air filter of 10 microns size particle arrestance capacity. The FCUs shall be fitted with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings,with On/Off switch, thermostat and three speed fan switch controls, complete as per specifications. Capacities of the FCUs: - 3 TR/1200 CFM

1

-

-

... More
Supply, installing, testing and commissioning of electrically operated drain pump and internal drain piping suitable for automatic operation for draining the condensate water of High Wall type FCUs. These pumps are to be fitted in the FCUs which are installed in locations where the drain piping has to be raised by about 450 mm to lift it above the false ceiling level, for draining to the nearest building drain point.

86

-

-

... More
Supply, installation, testing and commissioning of chilled water Fan Coil Units, Cassette type, 4-way air flow type, complete with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings, cordless remote control with On/Off, thermostat and fan three speed functions, and mounting arrangement complete as per specifications. Capacities of the FCUs: - 3 TR

1

-

-

... More
Supply, installation, testing and commissioning of chilled water Fan Coil Units, Cassette type, 4-way air flow type, complete with one ball valve with strainer at the inlet, one ball valve and 2-way motorised valve at the outlet, copper tubes and fittings, cordless remote control with On/Off, thermostat and fan three speed functions, and mounting arrangement complete as per specifications. Capacities of the FCUs: - 4 TR

1

-

-

... More
CPWD code no.16.2 MR - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 20 mm dia

510

-

-

... More
CPWD code no.16.2.14 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 25 mm dia

360

-

-

... More
CPWD code no.16.2.13 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 32 mm dia

280

-

-

... More
CPWD code no. 16.2.12 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 40 mm dia

210

-

-

... More
CPWD code no.16.2.11 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 50 mm dia

460

-

-

... More
CPWD code no.16.2.10 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 65 mm dia

352

-

-

... More
CPWD code no.16.2.9 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 80 mm dia

710

-

-

... More
CPWD code no.16.2.8 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 100 mm dia

640

-

-

... More
CPWD code no.16.2.7 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 125 mm dia

120

-

-

... More
CPWD code no.16.2.6 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 150 mm dia

105

-

-

... More
CPWD code no.16.2.5 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 200 mm dia

90

-

-

... More
Supply, Installation, Testing and commissioning of Ball valves in the chilled water pipe lines, including necessary fittings like flanges, reducers, tees and fasteners, and insulating the valves, after pressure testing as per the specifications for the chilled water piping. - 20 mm size

4

-

-

... More
Supply, Installation, Testing and commissioning of Ball valves in the chilled water pipe lines, including necessary fittings like flanges, reducers, tees and fasteners, and insulating the valves, after pressure testing as per the specifications for the chilled water piping. - 25 mm

4

-

-

... More
Supply, Installation, Testing and commissioning of Ball valves in the chilled water pipe lines, including necessary fittings like flanges, reducers, tees and fasteners, and insulating the valves, after pressure testing as per the specifications for the chilled water piping. - 32 mm

6

-

-

... More
Supply, Installation, Testing and commissioning of Ball valves in the chilled water pipe lines, including necessary fittings like flanges, reducers, tees and fasteners, and insulating the valves, after pressure testing as per the specifications for the chilled water piping. - 40 mm

8

-

-

... More
CPWD code no. 16.7.1.7 - Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified - 50 mm size

2

-

-

... More
CPWD code no.16.7.1.6 - Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified - 65 mm

28

-

-

... More
CPWD code no.16.7.1.5 - Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified - 80 mm

10

-

-

... More
CPWD code no.16.7.1.4 - Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified - 100 mm

2

-

-

... More
CPWD code no.16.7.1.3 - Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified - 125 mm

8

-

-

... More
2-Way Motorised valves with actuators, step down transformers and thermostats, BMS compatible.- 25 mm size

1

-

-

... More
2-Way Motorised valves with actuators, step down transformers and thermostats, BMS compatible. - 32 mm

3

-

-

... More
2-Way Motorised valves with actuators, step down transformers and thermostats, BMS compatible. - 40 mm

4

-

-

... More
2-Way Motorised valves with actuators, step down transformers and thermostats, BMS compatible. - 50 mm

1

-

-

... More
2-Way Motorised valves with actuators, step down transformers and thermostats, BMS compatible.- 65 mm

14

-

-

... More
2-Way Motorised valves with actuators, step down transformers and thermostats, BMS compatible. - 80 mm .

4

-

-

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.: - 25 mm

1

-

-

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.:- 32 mm

3

-

-

... More
CPWD code no. 16.7.2.8 - BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.:- 40 mm

4

-

-

... More
CPWD code no. 16.7.2.7 - BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.:- 50 mm

1

-

-

... More
CPWD code no. 16.7.2.6 - BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.:- 65 mm

14

-

-

... More
CPWD code no. 16.7.2.5 - BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.:- 80 mm

4

-

-

... More
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.- 25 mm size

1

-

-

... More
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.- 32 mm

3

-

-

... More
CPWD code no. 16.7.4.8 - Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.- 40 mm

4

-

-

... More
CPWD code no. 16.7.4.7 - Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.- 50 mm

1

-

-

... More
CPWD code no. 16.7.4.6 - Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.- 65 mm

14

-

-

... More
CPWD code no. 16.7.4.5 - Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.- 80 mm

4

-

-

... More
Supply, Installation, Testing and commissioning of AHU and FCU drain piping of Heavy duty pvc pipes and fittings, insulated with 6 mm thick nitrile rubber sleeves. Size: - 25 mm

210

-

-

... More
Supply, Installation, Testing and commissioning of AHU and FCU drain piping of Heavy duty pvc pipes and fittings, insulated with 6 mm thick nitrile rubber sleeves. Size: -32 mm

120

-

-

... More
Supply, Installation, Testing and commissioning of AHU and FCU drain piping of Heavy duty pvc pipes and fittings, insulated with 6 mm thick nitrile rubber sleeves. Size:- 40 mm

110

-

-

... More
Supply, Installation, Testing and commissioning of AHU and FCU drain piping of Heavy duty pvc pipes and fittings, insulated with 6 mm thick nitrile rubber sleeves. Size:- 50 mm

55

-

-

... More
CPWD code no.16.12.1.1 - Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.- 0.63 mm

2170

-

-

... More
CPWD code no.16.12.1.2 - Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. - 0.8 mm

1400

-

-

... More
CPWD code no.16.12.1.3 - Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. - 1.00 mm

180

-

-

... More
CPWD code no.16.12.1.4 - Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.- 1.25 mm

50

-

-

... More
Supply, installation, testing and commissioning of rectangular air ducts fabricated out of Aluminium sheets of the following sheet thickness. The ducts must be machine fabricated and must be air-tight and have a neat finish. The ducting shall be complete with fasteners and gaskets at all joints. The ducts shall be supported from the ceiling with anchor fasteners, threaded rods of GI and support angles. The ducting shall conform to IS:655 and it's latest amendments. Please see the relevant item under Technical Specifications. - 0.8 mm thick

670

-

-

... More
Supply, installation, testing and commissioning of rectangular air ducts fabricated out of Aluminium sheets of the following sheet thickness. The ducts must be machine fabricated and must be air-tight and have a neat finish. The ducting shall be complete with fasteners and gaskets at all joints. The ducts shall be supported from the ceiling with anchor fasteners, threaded rods of GI and support angles. The ducting shall conform to IS:655 and it's latest amendments. Please see the relevant item under Technical Specifications. - 1.0 mm thick

110

-

-

... More
Supply, installation, testing and commissioning of rectangular air ducts fabricated out of Aluminium sheets of the following sheet thickness. The ducts must be machine fabricated and must be air-tight and have a neat finish. The ducting shall be complete with fasteners and gaskets at all joints. The ducts shall be supported from the ceiling with anchor fasteners, threaded rods of GI and support angles. The ducting shall conform to IS:655 and it's latest amendments. Please see the relevant item under Technical Specifications. - 1.25 mm thick

50

-

-

... More
Supply, installation, testing and commissioning of spiral wound circular ducting of 0.63 mm thick Aluminium sheet, as per ISS 655, factory made, complete with necessary fittings like reducers, bends, take-off collars, grill collars, dummy ends etc. and suitable anchor fasteners, GI threaded rods, fasteners etc. for installation.

50

-

-

... More
Supply, installation, testing and commissioning of spiral wound circular ducting of 0.63 mm thick GI sheet, as per ISS 655, factory made, complete with necessary fittings like reducers, bends, take-off collars, grill collars, dummy ends etc. and suitable anchor fasteners, GI threaded rods, fasteners etc. for installation.

740

-

-

... More
DSR 16.13 - Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications..

16

-

-

... More
DSR 16.15 -Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

18

-

-

... More
DSR 16.16 - Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

24

-

-

... More
DSR 16.17 - Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

22

-

-

... More
DSR 16.18 - Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

24

-

-

... More
Supply, Installation, Testing and commissioning of External Thermal insulation for the ducts with EPS slabs of TF quality and covered with aluminium foil as per the specifications. - With 25 mm thick EPS slabs

36

-

-

... More
Supply, Installation, Testing and commissioning of External Thermal insulation for the ducts with EPS slabs of TF quality and covered with aluminium foil as per the specifications. - With 50 mm thick EPS slabs

20

-

-

... More
CPWD code no. 16.23.1 - Supplying and fixing of following thickness duly laminated aluminum foil of matt finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. - 19 mm thick insulation

4160

-

-

... More
CPWD code no. 16.23.2 - Supplying and fixing of following thickness duly laminated aluminum foil of matt finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.- 25 mm thick insulation

250

-

-

... More
DSR 16.21 - Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.

270

-

-

... More
Supply and fixing of acoustic lining for initial portion of supply air ducts with open cell nitrile rubber sheet of minimum density 140 kgs/cub. mt. and 10 mm thick, with fire retardant and anti microbial properties as per the Technical Specifications. The rubber sheet shall be firmly fixed to the inside of the duct with suitable adhesive and bolted down at intervals.

610

-

-

... More
Supply, Installation, Testing and commissioning of Fire damper of GI sheet operated by fusible links.

12

-

-

... More
Supply, Installation, Testing and commissioning of Fresh air intake with cowl, wire netting, pre filter and Volume Control Damper of GI sheet

5

-

-

... More
Supply, Installation, Testing and commissioning of CO2 Sensor and Damper Motor actuated by the Sensor for the Fresh Air Dampers for AHU areas

16

-

-

... More
Supply, installation, testing and commissioning of under deck insulation for roof areas exposed to sun light, using 23 mm thick fire retardant closed cell nitrile rubber sheets as per the Technical Specifications.

1550

-

-

... More
External HVAC - Supply, Installation, Testing and Commissioning of High Efficiency Water cooled screw type chiller as per specifications. The capacity of the chilling package shall be 225 TR (790 kw cooling capacity) each, at the duty conditions of 12ºC to 7ºC chilled water and 32.2 ºC to 36.4ºC condenser water temperatures. The quoted price shall include customs and other duties at full rate; all local taxes, levies etc. that are applicable; port clearance, warehouse charges, handling, transportation to site; rigging, installation, testing, commissioning and handing over. Input power to the chiller at full load conditions must be less than 0.65 Ikw per TR i.e. the Coefficient of Performance (COP) shall be not less than 5.4.

3

-

-

... More
Supply, Installation, Testing and Commissioning of Chiller Plant Manager for remote operation and monitoring of Chillers, Cooling Tower Fan Motors, Condenser Water Pumps, Primary and Secondary Chilled Water Pumps.This shall be compatible with BMS.

1

-

-

... More
Supply, Installation, Testing and Commissioning of 250 TR (937500 kcals per hr) capacity induced draft cooling tower, while operating at 28 deg C ambient WB temperature. The cooling tower must be sized for handling 225 cubic metres per hour water flow at a temperature difference of 4.2 deg C.

3

-

-

... More
Supply Installation Testing and Commissioning of condenser water pump having a capacity of 60 LPS at 24 mts. w.g. total head.

3

-

-

... More
Supply Installation Testing and Commissioning of primary chilled water pump having a capacity of 39 LPS at 12 mts. w.g. total head.

3

-

-

... More
Supply Installation Testing and Commissioning of secondary chilled water pump having a capacity of 39 LPS at 32 mts. w.g. total head.

3

-

-

... More
Supply, Installation,Testing and Commissioning of Variable Frequency Drive arrangement for the secondary pump motors - consisting of adjustable frequency drive (AFD) and Pressure sensors / transmittors for each pump. The pumps and VFD must be compatible. Pump capacity 39 LPS at 32 mts. w.g. total head.

3

-

-

... More
Supply, Installation,Testing and Commissioning of closed expansion tank of MS sheet construction and fitted with synthetic membrane, with steel mounting frame and insulated with 50 mm thick eps slabs, wire netting and cement plastering, and pressurisation system with two pumps, one working, one standby, pressure switch, isolating valves and pressure gauges, all mounted on a steel frame, finished with epoxy paint. Make-up water piping from the overhead tank is also to be provided. Tank capacity 1000 lts.

1

-

-

... More
CPWD, Ch. 16, HVAC, Item16.2.6 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 150 mm dia (32 mm thick insulation)

62

-

-

... More
CPWD, Ch. 16, HVAC, Item16.2.5 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 200 mm dia (32 mm thick insulation)

24

-

-

... More
CPWD, Ch. 16, HVAC, Item16.2.4 - Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 250 mm dia (32 mm thick insulation)

90

-

-

... More
Supply, installation, testing and commissioning of chilled water piping complete with MS 'C' class pipes and fittings and pipe supports and insulated with closed cell nitrile rubber insulation, polythene sheet, wire netting and cement plastering and covered with tarfelt as per the Technical Specifications, for burying under ground. Pipe sizes: - 150 mm dia (32 mm thick insulation)

12

-

-

... More
Supply, installation, testing and commissioning of chilled water piping complete with MS 'C' class pipes and fittings and pipe supports and insulated with closed cell nitrile rubber insulation, polythene sheet, wire netting and cement plastering and covered with tarfelt as per the Technical Specifications, for burying under ground. Pipe sizes:- 200 mm dia (32 mm thick insulation)

48

-

-

... More
Supply, installation, testing and commissioning of chilled water piping complete with MS 'C' class pipes and fittings and pipe supports and insulated with closed cell nitrile rubber insulation, polythene sheet, wire netting and cement plastering and covered with tarfelt as per the Technical Specifications, for burying under ground. Pipe sizes: - 250 mm dia (32 mm thick insulation)

12

-

-

... More
DSR 16.7.1.2 - Supply, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified - 150 mm dia

18

-

-

... More
DSR 16.7.2.2 - BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. - 150 mm dia

3

-

-

... More
DSR 16.7.3.2 - NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. - 150 mm dia

6

-

-

... More
DSR 16.7.4.2 - Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. - 150 mm dia

3

-

-

... More
Supply, Installation,Testing and Commissioning of automatic air purge valves of size : 20 mm dia

12

-

-

... More
Supply, installation, testing and commissioning of Condenser water piping of GI 'C' class pipes and fittings as per the Technical Specifications. Sizes: - 25 mm

12

-

-

... More
Supply, installation, testing and commissioning of Condenser water piping of GI 'C' class pipes and fittings as per the Technical Specifications. Sizes: - 40 mm

6

-

-

... More
Supply, installation, testing and commissioning of Condenser water piping of GI 'C' class pipes and fittings as per the Technical Specifications. Sizes: - 50 mm

6

-

-

... More
Supply, installation, testing and commissioning of Condenser water piping of GI 'C' class pipes and fittings as per the Technical Specifications. Sizes: - 200 mm

66

-

-

... More
Supply, installation, testing and commissioning of Condenser water piping of GI 'C' class pipes and fittings as per the Technical Specifications. Sizes: - 300 mm

110

-

-

... More
DSR 16.11.1.3 - Supply, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. - 200 mm

18

-

-

... More
DSR 16.11.2.3 - NON - RETURN VALVE with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. - 200

3

-

-

... More
Supply, Installation,Testing and Commissioning of Y- type strainer with fittings. - 200

3

-

-

... More
Supply, Installation,Testing and Commissioning of Balancing valves for condensers. - 200

3

-

-

... More
Supply, Installation,Testing and Commissioning of Flow switches for condensers and chillers

6

-

-

... More
16.8 - Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

30

-

-

... More
16.9 - Providing & fixing in position the mercury in glass industrial type thermometers.

12

-

-

... More
Supply, Installation,Testing and Commissioning of Ventilation blowers of 4000 cfm air flow capacity at 25 mm wg total static pressure for CSSD. The blowers shall be similar in construction to AHUs and shall consist of DIDW centrifugal blowers, suitable capacity drive motor, drive arrangement, air filter and base frame with vibration isolators all mounted inside a cabinet fabricated out of extruded aluminium section frame and double skin panels with 20 mm thick PUF insulation inbetween. The cabinet shall be provided with access doors and be suitable for ceiling suspension.

2

-

-

... More
Karnataka PWD, SOR Electrical items, Item7.2.1 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230 V 50 Hz, AC Supply complete.- 12 inch Sweep (300 mm)

12

-

-

... More
AC Exhaust fan 375 mm (15") sweep (heavy duty)

8

-

-

... More
AC Exhaust fan 450 mm (18") sweep (heavy duty)

6

-

-

... More
AC Exhaust fan 600 mm (24") sweep (heavy duty)

2

-

-

... More
AC Exhaust fan 225 mm (9") sweep.

56

-

-

... More
Supply, Installation,Testing and Commissioning of Louver Shutters arrangements for Exhaust fans for Toilets and AC Plant Room Ventilation. - MS / Fibre louver shutter arrangement for 300 mm AC exhaust fan

12

-

-

... More
Supply, Installation,Testing and Commissioning of Louver Shutters arrangements for Exhaust fans for Toilets and AC Plant Room Ventilation. - MS / Fibre louver shutter arrangement for 375 mm AC exhaust fan

8

-

-

... More
Supply, Installation,Testing and Commissioning of Louver Shutters arrangements for Exhaust fans for Toilets and AC Plant Room Ventilation. - MS / Fibre louver shutter arrangement for 450 mm AC exhaust fan

6

-

-

... More
Supply, Installation,Testing and Commissioning of Louver Shutters arrangements for Exhaust fans for Toilets and AC Plant Room Ventilation. - MS / Fibre louver shutter arrangement for 600 mm AC exhaust fan

2

-

-

... More
Supply, Installation,Testing and Commissioning of sheet metal mounting Cabinet for Exhaust fans complete with flange for exhaust duct connection and access dor for fan maintenance. - For 375 mm dia exhaust fan

8

-

-

... More
Supply, Installation,Testing and Commissioning of sheet metal mounting Cabinet for Exhaust fans complete with flange for exhaust duct connection and access dor for fan maintenance. - For 450 mm dia exhaust fan

6

-

-

... More
Supply, Installation,Testing and Commissioning of sheet metal mounting Cabinet for Exhaust fans complete with flange for exhaust duct connection and access dor for fan maintenance. - For 600 mm dia exhaust fan

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.