Military Engineer Services Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

lockUnlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

lockUnlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

lockView all details for FREE
... More
All as per Sl Item No. 2 above but 4 way RMU all as specified and directed.

3

-

-

... More
All as per Sl Item No. 2 above but 5 way RMU all as specified and directed.

3

-

-

... More
Material and labour for maintenance, servicing and oil leakage arresting up to 250 KVA, 11KV rating distribution Transformer, providing necessary gaskets, Oil Seals, cleaning, dusting, decarbonising, tightening loosened parts, including replacing worn out parts, copper studs, bolts, nuts and washers replacing oil Seals, HT bush, gasket including unserviceable coil, replacing of defective minor items such as, as and when required complete all as specified and as directed. NOTE :- The item spare parts and oil to be replaced shall be measured and paid separately, However minor items such as Gasket, nut and bolt shall be deemed to be included in the unit rate quoted. The rates are inclusive of crane charges for lifting and re assembling from the structure.

3

-

-

... More
All as per Sl Item No. 6 above but of capacity above 250 KVA to 500 KVA, 11 KV rating

5

-

-

... More
All as per Sl Item No. 6 above but of capacity above 500 KVA to 1000 KVA, 11KV rating

3

-

-

... More
Supply and fix in repairs HT bushing rod complete with insulator and packing suitable for out door / indoor type 63 KVA to 500 KVA, 11KV rating transformers confirming to IS-334 complete with nut, bolts, brass studs and gasket of synthetic rubber bonded cork sheet complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
All as per Sl Item No. 9 above but for capacity above 500 KVA and upto 1000 KVA, 11KV rating.

2

-

-

... More
Supply and fix in repairs LT bushing complete with insulator and packing suitable for 1100 volt grade complete with nut, bolts, brass studs, insulator and gasket etc suitable for 63 to 500 KVA, 11 KV rating out door / indoor transformer complete all as specified and as directed.

4

-

-

... More
All as per Sl Item No. 11 above but for capacity above 500 KVA to 1000 KVA, 11KV rating NOTE FOR SL ITEM No. 09 to 12 : - 1. Rate quoted by the contractor shall be deemed to include for opening of top plate of transformer / decanning of oil from transformer up to the level as per requirement and assemble the same after replacement of bushing rod. 2. Bushing rod shall be replaced at site. Transformer will not be allowed to send to workshop at any cost and all bushing replacement work shall be executed at site only.

3

-

-

... More
Material and labour for filtration of transformer oil through stream line filtration plant for extracting moisture content in the oil and carbon deposits and bringing the di-electric strength not less than 60 KV for one minute with sphere gap of 2.5 mm including checking the value of acidity of oil with a acidity test kit and submitting test report for die electric strength and acidity of transformer oil before / after filtration complete all as specified and as directed. NOTE : 1.The contractor should submit the Test sheet for all transformer in which dehydration of transformer oil carried out

12813

-

-

... More
Supply and filling of new transformer oil confirming to IS 335-1963 as amended and die electric strength not less than 60 KV for topping up / replacement of unserviceable transformer oil complete all as specified and as directed.

1656

-

-

... More
Taking down old unserviceable DC power pack, supply and fix DC power pack, LT, 230 V AC input and output 110 / 30 V DC for energizing tripping and closing coil installed in VCB / OCB complete all as specified and as directed.

7

-

-

... More
Supply and fix in replacement Multi Data Meter, 11 KV, size 96 mm x 96 mm including taking down the existing one all complete all as specified and as directed. MAKE :- SCHNEIDER / L&T / ELMEASURE

7

-

-

... More
Supply and fix in repairs silica gel breather assembly transparent type with first fill of silica gel suitable for 100 to 315 KVA, 11 KV rating (1/2 kg) transformers complete including connecting with proper rubberized gasket complete all as specified and as directed.

10

-

-

... More
Supply and fix in repairs silica gel breather assembly transparent type with first fill of silica gel suitable for 400 to 750 KVA, 11 KV rating (1 kg) transformers including connecting with proper rubberized gasket complete all as specified and as directed.

12

-

-

... More
Supply and fix in repairs silica gel breather assembly transparent type with first fill of silica gel suitable for 1000 KVA (1 kg) transformers including connecting with proper rubberized gasket complete all as specified and as directed.

1

-

-

... More
Supply and fix in replacement of silica gel in existing breather assembly of any capacity of transformer complete all as specified and directed. MAKE :- SCHNEIDER / ABB / L&T

10

-

-

... More
Material and labour for spray painting of distribution transformer with two coats of synthetic enamel paint of smoke grey colour after neatly cleaning and preparing the surface for spray painting the transformer of the following capacity including writing SM / MES No (5cm height) with white enamel paint of capacity upto 250 KVA, 11KV rating transformer complete all as specified and as directed.

3

-

-

... More
All as per Sl Item No. 21 above but of capacity above 250 KVA and upto 500 KVA, 11 KV rating

14

-

-

... More
All as per Sl Item No. 21 above but of capacity above 500 and upto 1000 KVA, 11 KV rating

5

-

-

... More
Supply and refilling of SF6 (Sulfur hexafluoride gas) for 66 KV SF6 outdoor circuit breaker to cool and Quench the arc on opening of circuit transmission class discharge capacity of 69KV for normal operation to maintain the desired pressure in SF6 and RMU as per OEM design and testing the pressure of each SF6 breaker of 66 KV and 11 KV RMU complete all as specified and as directed.

25

-

-

... More
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in hard / dense soil complete all as specified and as directed by Engineer-in-Charge.

28.76

-

-

... More
Removing excavated material to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.

5.29

-

-

... More
Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm complete all as specified and as directed by Engineer-in -Charge.

20.39

-

-

... More
Supply and spread soft soil sand duly filtered the sand in trenches for cable cushioning on both top and bottom of cable including ramming complete all as specified and as directed.

5.75

-

-

... More
Material and labour for un-reinforced precast concrete covers class HV type 300mm x 180mm x 40mm size factory made for cable protection complete all as specified and as directed.

550

-

-

... More
Supply, laying, testing, jointing and commissioning XLPE insulated cable, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor of size 120 sq.mm 3 core 11000 Volt grade (11 KV earthed) laid in trenches / fixed on pole including taking out existing defective cable complete all as specified and as directed. NOTE :- Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately.

80

-

-

... More
Supply, laying, testing, jointing and commissioning XLPE insulated cable, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor of size 95 sq.mm 3 core 11000 Volt grade (11 KV earthed) laid in trenches / fixed on pole including taking out existing defective cable complete all as specified and as directed. NOTE :- Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately.

200

-

-

... More
Supply and fix in replacement Digital Ammeter, 11 KV, size 96mm x 96mm including taking down the existing one all complete all as specified and as directed. MAKE :- SCHNEIDER / L&T / ELMEASURE

25

-

-

... More
Supply and fix in replacement Digital Voltmeter, 11 KV, size 96mm x 96 mm including taking down the existing one complete all as specified and as directed. MAKE :- SCHNEIDER / L&T / ELMEASURE

25

-

-

... More
Supply and fix RED, YELLOW, GREEN, BLUE, AMBER & WHITE LED Indication Lamps Range (24 - 240 V AC / DC) for the existing HT VCB / OCB / RMU 11 KV Panels including taking out old unserviceable lamps complete all as specified and as directed.

50

-

-

... More
Supply and fix of HT current transformer 11 KV rating of capacity 200 / 100 / 5-5 including testing commissioning through primary injection method with suitable testing kit and also checking the control panel wiring including setting the CT range with relays setting for proper functioning / tripping and taking out old unserviceable CT complete all as specified and as directed. MAKE :-KALPA / KAPPA / ABB

3

-

-

... More
Supply and fix in replacement of Potential Transformer moulded in epoxy compound with dual ration 50 / 25 / 5 Amps complete connection with copper wire including beading as per existing VCB 11 KV at site complete all as specified and as directed by Engineer-in Charge. MAKE :- ABB / KALPA / KAPPA

3

-

-

... More
Replacement of unserviceable existing make and model IDMT relay numerical non directional over current and earth fault relay with communication feature (RS 485) with full automation system type Argus, LT, Aux voltage 110 volt DC should comprise of the following featureS :- (a) Three phase over current and one earth fault. (b) High set - low set. (c) RS-485 with full communication system. (d) Multi characteristic for both over current and earth fault, Make: L&T / SCHNEIDER / SEIMENS / ABB / C&S

7

-

-

... More
Material and labour for calibration of IDMT relays set of 11KV rating of three through relay test kit including other required measuring equipment to the site by secondary injection method and testing for proper functioning / tripping systems of relays complete all as specified and as directed. NOTE :- The rate quoted by the contractor is deemed to be included for quarterly checking of relays in VCB / OBC for its proper setting / functioning and tripping of VCB / OCB during over load / earth fault.

15

-

-

... More
Supply and laying Sealing Compound bitumen for arresting of holes at VCB / OCB / SF6 Breaker panels 11 KV rating etc complete all as specified and as directed.

20

-

-

... More
Supply and fix in replacement of spring charge universal motor suitable for 11 KV, VCB, working on 230 volt of existing make i.e CG / Schneider / ABB / L&T etc complete all as specified and as directed.

4

-

-

... More
Material and labour for chemical earthing complete with copper earth plate electrode 600 x 600 x 5mm thick buried directly in ground (earth pit not less than 3 mtr deep below ground level) with top edge of the plate not less than 2.10 mtr below normal ground level, connected to and including copper earth strip of 32mm x 6 mm by means of riveting and brazing and protected by GI pipe light grade of suitable size up to the test point i.e. up to 7.5 mtr, including providing alternate layers up to full volume of pit by charcoal dust and common salt, magnesium sulphate and vegetable soil all around the plate 15 cm depth and width minimum including PCC pit chamber, watering pipe of 50mm dia medium grade GI pipe up to the top of the plate having funnel complete and RCC cover, connecting to the test point and testing on ground complete and including excavation and earth work in any type of strata and cleaning of site all as specified in MES SSR Part-I complete all as specified and as directed by Engineer-in-Charge.

7

-

-

... More
Supply and fix earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 32mm x 6mm complete all as specified and as directed.

40

-

-

... More
Supply and laying Synthetic Insulating Mat of size 2.00 Mtr x 1.00 Mtr x 19 mm thick LT 1100 volts grade complete all as specified and as directed.

7

-

-

... More
Supply and fix GI pipe light grade 80mm dia with all fittings for protection of HT cable under road or on wall complete all as specified and as directed by Engineer- in-Charge.

20

-

-

... More
Supply and fix of Master Tripping Relay rating of 24 / 30 / 110 V DC for the existing HT VCB / OCB / RMU 11 KV Panels complete all as specified and as directed. MAKE :- EASUN REYROLLE / C&S

3

-

-

... More
Supply and fix tripping and closing coil with complete assembly for 11 KV SF6 breaker DC 24 / 30 Volts as per existing one including taking out old unserviceable coil assembly complete all as specified and as directed

3

-

-

... More
Supply and fix Trip-Neutral-Close (TNC) Switch, fixing with the existing HT VCB/OCB 11 KV Panel for including taking out old unserviceable TNC Switch complete all as specified and as directed. MAKE :- KAYCEE OR EQUIVALENT

10

-

-

... More
Supply and fix HT spout bushing for VCB HT 11 KV, busbar side including taking out old unserviceable bushing complete all as specified and as directed.

3

-

-

... More
Supply and fix in replacement of big and small end bearing of HT 11 KV VCB trolly including replacement of complete locking mechanism with integral spring charging handle for manual spring charge and replacement of closing coil and tripping coil 24V DC including replacement of electro magnetic relay, coil rating 230 V, AC of existing sample of make of Crompton Greaves / ABB / Schneider complete all as specified and as directed.

1

-

-

... More
Supply and fix in replacement of moving contact assembly suitable for HT OCB 11 KV 400 Amps to 800 Amps OCB as per existing including dismantling the old unserviceable moving contact assembly suitable for HT OCB complete all as specified and as directed.

5

-

-

... More
Supply and fix in replacement resin encapsulated vacuum interrupter bottles of the same manufacturers as per existing circuit breaker trolley of 11 KV complete all as specified and as directed. MAKE :-ABB / SCHNEIDER / L&T / CG

3

-

-

... More
Supply and fix of Tripping coil for 11 KV 400 / 800 Amp VCB 30 / 110 V DC including taking out old unserviceable coil complete all as specified and as directed.

8

-

-

... More
Supply and fix of Closing coil for 11 KV 400 / 800 Amp VCB 30 / 110 V DC including taking out old unserviceable coil complete all as specified and as directed.

4

-

-

... More
Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried in ground vertically to a depth not less than 2.25mtrs below normal ground level with top edge of the plate not less than 1.5mtrs below ground level connected to galvanised iron / steel strip of size 32mm x 6mm thick by means of bolts, nuts, check nuts and washer made out of galvanised iron or steel all as shown in electrical plate No-03 of SSR part I and earth strip protected by GI pipe light grade 40mm bore and through test point including necessary earth work and excavation in any type of soil, GI light grade 20 watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab 6mm dia MS bars at 100mm c/c both ways with MS Hooks 6mm dia ms bars etc complete all as specified and as directed and testing on completion. NOTE : GI Strip upto 7.5 Mtr length shall be deemed to include in this item.

6

-

-

... More
Material and labour for finding out the cable fault of any size of cable upto 11 KV underground cable (HT and LT and of any capacity of cable with the help of cable fault locator mounting on vehicle and with necessary disconnection of cable from two ends and making connection by jointing after repairs and having the following items with electrician at site to find fault of up to length of 10 KM cable complete all as specified and directed by Engineer-in-Charge with help of the following accessories :- (a) Surge Generator with accessories. (b) Head Phone. (c) Pin Point Set T-505 with accessories. (d) Earthing cable with clamp. (e) Cable fault Locator T-905 with accessories. (f) TC-808 with accessories. (g) Soldering Iron / wire / capacitor unit / capacitor connecting cables / power cable / nose plier complete all as specified and as directed. NOTE :- Excavation for the cable fault shall be done by the contractor and included in the quoted rate.

2

-

-

... More
Material and labour for cutting of black top cover of existing road up to 1 mtr depth and 60 cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 upto 30cm from top of the road surface complete all as specified and as directed by Engineer-in-Charge. NOTE :- UG cable and pipe line will be measured and paid separately.

14

-

-

... More
Material and labour for Earthing complete with copper earth plate electrode 600 x 600 x 3.15mm thick buried directly in ground (earth pit not less than 3 mtr deep below ground level) with top edge of the plate not less than 2.10 mtr below normal ground level, connected to and including copper earth strip of 32mmx6 mm by means of riveting and brazing and protected by GI pipe light grade of suitable size up to the test point i.e. up to 7.5 mtr, including providing alternate layers up to full volume of pit by charcoal dust and common salt, all around the plate 15 cm depth and width minimum including PCC pit chamber, watering pipe of 50mm dia medium grade GI pipe up to the top of the plate having funnel and RCC cover, connecting to the test point and testing on ground and including excavation and earth work in any type of strata and cleaning of site all as specified in MES SSR Part-I complete all as specified and as directed by Engineer-in-Charge.

8

-

-

... More
Material and labour for copper earth continuity main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit of size 20mm x 3mm complete all as specified and as directed.

235

-

-

... More
Supply and fix cable jointing kit for 11 KV grade cable for in door termination joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 sq.mm including taking out old unserviceable joint kit complete all as specified and as directed.

3

-

-

... More
Supply and fix cable jointing kit for 11 KV grade cable for in door termination joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sq.mm including taking out old unserviceable joint kit complete all as specified and as directed.

3

-

-

... More
Supply and fix cable jointing kit for 11 KV grade cable for out door termination joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 sq.mm including taking out old unserviceable joint kit complete all as specified and as directed.

2

-

-

... More
Supply and fix cable jointing kit for 11 KV grade cable for out door termination joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sq.mm including taking out unserviceable joint kit complete all as specified and as directed.

2

-

-

... More
Supply and fix cable jointing kit for 11 KV grade cable for straight through joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 sq.mm including taking out unserviceable joint kit complete all as specified and as directed.

2

-

-

... More
Supply and fix cable jointing kit for 11 KV grade cable for straight through joint kit heat shrinkable type with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sq.mm including taking out unserviceable joint kit complete all as specified and as directed.

2

-

-

... More
Dismantling carefully after taking shutdown for SF-6 breaker 11 KV, material and labour charges for battery charger input voltage 88-265 V AC and out put voltage 24V DC 7.5A suitable for SF-6 breaker including testing complete all as specified and as directed. Make: ALAN or Equivalent.

10

-

-

... More
Supply and fix sealed lead acid battery 12V, 7 Ah suitable for SF-6, 11 KV breaker battery charger including taking out unserviceable battery from SF-6 Breaker complete all as specified and as directed. MAKE :- EXIDE / AMARON / LUMINOUS

14

-

-



Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.