Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Pipe Line Project
Water Storage And Supply
Eprocure
Opening Date14 Feb 2025
Closing Soon7 Mar 2025
Tender Amount₹ 49,99,000 
Notes
Download

Costs

Summary

Repair Maint Of Raising Main Distribution Pipeline Periodical Cleaning Of Bldg Service Tanks And Other Misc Water Supply Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with providing new GI fittings where ever replaced and required at site of size 40 to 50 mm bore complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately

100

-

-

... More
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with providing new GI fittings where ever replaced and required at site of size 25 mm bore complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately

120

-

-

... More
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with providing new GI fittings where ever replaced and required at site of size 20 mm bore complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately

80

-

-

... More
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with providing new GI fittings where ever replaced and required at site of size 15 mm bore complete all as specified directed.

70

-

-

... More
Supply & Fix as in replacement of GI tubing medium grade of size 50 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately

120

-

-

... More
Supply & Fix as in replacement of GI tubing medium grade of size 40 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately

140

-

-

... More
Supply & Fix as in replacement of GI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately

200

-

-

... More
Supply & Fix as in replacement of GI tubing medium grade of size 20 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately

230

-

-

... More
Supply & Fix as in replacement of GI tubing medium grade of size 15 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately

280

-

-

... More
S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm complete all as specified and directed.

8

-

-

... More
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 40 mm complete all as specified and directed.

8

-

-

... More
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed.

12

-

-

... More
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm complete all as specified and directed.

5

-

-

... More
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 15 mm complete all as specified and directed.

5

-

-

... More
Demolition of Brickwork or precast concrete block walling including wall quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and concrete articles built in cement mortar complete all as specified or directed.

2

-

-

... More
M&L for Pre-cast cement concrete block masonry, type C1 (1:3:6), (using 20mm graded crushed stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and as directed.

2

-

-

... More
Material and Labour for Plain Cement Concrete (1:2:4), type B1 (using 20 mm graded stone aggregate) as in Coping, bands benching etc including finishing the concrete surfaces even and smooth without using extra cement including necessary form work complete all as specified or directed.

2

-

-

... More
Material and labour Cleaning of valve pit chamber for sluice/gate valve of 50/80/100/150/200/ size by removing mud/ grass/ sludge/ other waste materials from the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on cemented surfaces and one coat of synthetic paint on steel surfaces complete to make an operator friendly valve chamber complete as specified and directed. Note :- Periodicity and locations of valve chambers will be given as per requirement by the Engineer-in-Charge.

15

-

-

... More
Supply and fixing in replacement Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed

1

-

-

... More
Material and Labour for gland packing in leaking Sluice Valves of 100 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .

8

-

-

... More
Supply and fixing in replacement Sluice valve of size 80mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.

1

-

-

... More
Material and Labour for gland packing in leaking Sluice Valves of 80 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .

10

-

-

... More
Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all specified for tanks of capacity 200 to 500 Ltrs complete all as specified and directed.

120

-

-

... More
Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all specified for tanks o capacity 501-1000 Ltrs complete all as specified and directed.

60

-

-

... More
Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all specified for tanks of capacity 1001-2000 Ltrs complete all as specified and directed.

5

-

-

... More
Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCC Tanks all specified for tanks of capacity 2001-5000 Ltrs complete all as specified and directed.

3

-

-

... More
Supply and fix of PVC water tank 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting and taking down existing tank of any description and any capacity etc complete all as specified and directed.

12

-

-

... More
Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 20 mm complete all as specified and directed

150

-

-

... More
Supply and fix in repairs lids for polyethylene water storage tanks suitable for tank capacity upto 1000 Ltr, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and as directed .

500

-

-

... More
Supply and fix as in repair Nipple suitable for size 20 mm dia of HDPE/PVC water tank complete all as specified and as directed.

25

-

-

... More
Supply and fixing in repair 25 mm dia Unplasticiced PVC Pipes of pressure rating of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.

160

-

-

... More
Supply and fixing in repair 20 mm dia Unplasticiced PVC Pipes of pressure rating of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.

120

-

-

... More
Supply and fixing in repair UPVC Gate Valve of size 25 mm dia , ISI marked complete all as specified and as directed.

10

-

-

... More
Supply and fixing in repair UPVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed.

12

-

-

... More
Supply and fixing in repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.

80

-

-

... More
Supply and fixing in repair Chlorinated PVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed.

10

-

-

... More
Supply only calcium based high strength chlorination chemical for water in granular form chlorine concentration level having 65%-70% chlorine content packed in 45 Kg capacity in factory sealed HDPE Container superior quality suitable for treatment of drinking water complete all as specified and directed. Note:The material should be delivered at water supply installation as per direction of AGE E/M on required basis during the contract period.

1125

-

-

... More
Supply and fix of PVC water tank 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, incl disconnecting and taking down existing tank of any description and any capacity complete all as specified and directed.

8

-

-

... More
Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 25 mm complete all as specified and directed

250

-

-

... More
Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 40mm complete all as specified and directed

40

-

-

... More
Supply and fix in repairs lids for polyethylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and directed by Engineer-in Charge suitable for 1001 to 5000 Ltrs cap of tanks.

60

-

-

... More
Supply and fix as in repair of Nipple suitable of size 25 mm dia for HDPE/PVC water tank complete all as specified and as directed.

35

-

-

... More
Clearing the bushes trunk girth not exceeding 10 .00 cm and area around valve chambers upto 1.0 mtrs and depositing at a distance nexceeding 50 mtrs from starting point etc complete all as specified and directed

2800

-

-

... More
Making arrangement to flush out the existing pipe line of any type 15 mm to 32 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.

20

-

-

... More
Making arrangement to flush out the existing pipe line of any type 40 mmto 50 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.

10

-

-

... More
Note for item No 47 & 48 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This will be inclusive in quoted rate. (ii) Excavation and earth work required will be measured and paid seperately. (iii) The flushing out will be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This will be inclusive in quoted rate. (iv) If the delay is more then 06 hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 200/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.

-

-

-

... More
Cleaning of service tanks of the capacity as here-in-below on roof top of bldgs upto three storrey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properly inside with soda wash, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white bold letter such as "TANK CLEANED ON"--------- (month and year), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours early in the morning or late in evening. (ii) Contractor shall maintain a pucca bound register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted alongwith RAR. (iii) Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same. (iv) All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.

-

-

-

... More
(a) For RCC /PVC tank exceeding 200 litters and not exceeding 500 ltrs

3000

-

-

... More
(b) For RCC /PVC tank exceeding 501 litters and not exceeding 1000 ltrs

600

-

-

... More
(c) For RCC /PVC tank exceeding 1001 litters and not exceeding 2000 ltrs

300

-

-

... More
(d) For RCC /PVC tank exceeding 2001 litters and not exceeding 5000 ltrs

180

-

-

... More
(e) For RCC /PVC tank exceeding 5001 litters and not exceeding 25000 ltrs

40

-

-

... More
Supply and fix PVC water tank 2000 Ltrs Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, incl disconnecting and taking down existing tank of any description and capacity etc complete as specified and directed. .

4

-

-

... More
S & F in replacement Bib taps, cast copper alloy chronium plated with crutch or butterfly handle, screwed down, screwed for iron pipe fixed of size 15 mm for brass ferrule fancy type and fixed complete all as specified and directed.

40

-

-

... More
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.

82.62

-

-

... More
M & L for Bricks covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete as specified and directed.

7.14

-

-

... More
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD. (iv) Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.

18

-

-

... More
Supply and fix in reapir for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc along with suitable fittings for cable protection .

12

-

-

... More
Material and labour in repair for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian. Note: Excavation & earthwork shall be measured & paid seperately

350

-

-

... More
Material and labour in repair for 3 ½ core 50 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian Note: Excavation & earthwork shall be measured & paid seperately

400

-

-

... More
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 50 Sqmm to 70 Sqmm, complete all as specified and directed.

5

-

-

... More
Material and labour in repair for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian Note: Excavation & earthwork shall be measured & paid seperately

450

-

-

... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including providing HDPE pipe of 50 mm dia suitable for 0.4 mpa working pressure complete as specified and directed.

12

-

-

... More
Supply and fix 4 Pole MCCB ,415 volts,fixed type ,400 Amp, 50 Hz, with rupturing capacity 36 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments i.e screws,bolt, nut, washers incl taking out old unsv MCCB etc complete all as specified and directed. Make: Indoasian/L&T/ Legrand

1

-

-

... More
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thromoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 250 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out unserviceable old LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-

1

-

-

... More
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 36 KA - 01 No (Incomer). (b) On Load Change over front operated of capacity 160 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 02 Nos. (d) MCB SPN of 240 V of capacity 40 Amps 10 KA -02Nos. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).

-

-

-

... More
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.

25

-

-

... More
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.

-

-

-

... More
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.

-

-

-

... More
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.

-

-

-

... More
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.

-

-

-

... More
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.

-

-

-

... More
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).

-

-

-

... More
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.

-

-

-

... More
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.

-

-

-

... More
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.

-

-

-

... More
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.

-

-

-

... More
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.

-

-

-

... More
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.

-

-

-

... More
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.

-

-

-

... More
(xiv) The electrode shall carry manufacturer's name .

-

-

-

... More
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.

-

-

-

... More
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.

-

-

-

... More
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.

-

-

-

... More
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.

-

-

-

... More
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.

-

-

-

... More
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO.

25

-

-

... More
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.

30

-

-

... More
Supply and fix 4 Pole MCCB ,415 volts,fixed type ,200 Amp, 50 Hz, with rupturing capacity 25 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unsv MCCB etccomplete all as specified and directed. Make: Indoasian/L&T/ Legrand

1

-

-

... More
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thromoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out unserviceable old LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-

1

-

-

... More
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 02 Nos (Incomer). (b) On Load Change over front operated of capacity 400 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).

-

-

-

... More
Note :- An amount of Rs 77,010.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.