Military Engineer Services Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685430_1Tender No
8129/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply only Shunt trip & Closing coil
4
-
-
Supply only Vertical Connection Copper Adapter
4
-
-
Supply only Trip Indication switch
4
-
-
Supply only Spring Charged' indication switch
4
-
-
Supply only Castle key lock ; Type: CKI - 1
4
-
-
Supply only Making current release / Instanteneous trip ; Type: CS-MCR - 1
4
-
-
Supply only Earth Fault Relay ,Type : EFR 1
4
-
-
Supply only Draw out mould Base(Cradle Side) type : 6D-16D
5
-
-
Supply only Arcing Contacts ( Set of 1 No. Fixed & 1 No Moving) type 16 D
5
-
-
Supply only Main Isolating Contacts ( Jaw contacts) ( Set of 1 No. Fixed & 1 No Moving) type 16 D
5
-
-
Supply only Main fixed Contacts ( Upper Terminals) type 16 D
4
-
-
Supply only Lower Terminals with fitting plates Contacts (Upper Terminals) type : 16 D
4
-
-
Supply only Circuit Terminals/Draw out terminals Type : 16D
4
-
-
Supply only Main moving Contacts Assembly; type 16 D
4
-
-
Supply only Single pole unit for 16 D
2
-
-
Supply only Arc chutes; type 6 D - 16 D
5
-
-
Supply only Charging motor (110 V AC/DC ) or (220 V AC/DC) Type: 6D- 16 D
2
-
-
Disconnection and removing the unserveciable MCCB & Supply and fix new MCCB with thermal magnetic release Conforms to IS/IEC 60947-2 & IEC 60947-2 4 pole ,415 V ,400 A , 50 Hz , breaking capacity of 50 KA, complete all as directed by Engineer in charge.
2
-
-
All as per item No 21 here-in-above, but of capacity 250 A , 50 KA
2
-
-
All as per item No 21 here-in-above, but of capacity 200 A , 35 KA
2
-
-
All as per item No 21 here-in-above, but of capacity 100 A , 25 KA
2
-
-
All as per item No 21 here-in-above, but of capacity 63 A ,25 KA
2
-
-
Disconnection and removing the unserviceable servo motor unit along with shaft from the existing servo stabilizers ( Oil/Air cooled ) carefully and replace same with the identical equivalent servo controlling unit of same size and capacity consisting of Reverseble synchronous motor with constant speed - Instant Start/Stop operates on single phase 230 V , 50Hz suitable for Voltage stabilizer of capacity upto 750 KVA(Oil Cooled)
1
-
-
All as per item No 26 here-in-above, but but of capacity 400 KVA
1
-
-
All as per item No 26 here-in-above, but but of capacity 300 KVA
1
-
-
All as per item No 26 here-in-above, but but of capacity 200 KVA
2
-
-
All as per item No 26 here-in-above, but but of capacity 125 KVA
2
-
-
All as per item No 26 here-in-above, but but of capacity 100 KVA
2
-
-
Supply ,renewal / topping up of Transformer oil having di-electric strength not less than 60 KV/min instanteneous for olil cooled Isolation Transformers / Servo stabilizers complete all as directed by Engineer in charge . Make : Power oil / Servo /Veedol
345
-
-
Disconnection and Removing old unserviceable Battary charging unit and S & F Battery charging unit providing DC power supply to relays,meters etc. operates on 230 V Single Phase AC, Output 24 V DC for Auto synchronizing panel complete as required
2
-
-
Disconnection and Removing old unserviceable Battary charging unit and S & F Battery charging unit providing DC power supply to relays,meters etc. operates on 230 V Single Phase AC, Output 12 V DC for Auto synchronizing panel complete as required
2
-
-
Servicing of Automatic Power Factor Correction (APFC) panel monthly of the capacity 100 to 125 kVAr complete comprising any type capacitors, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge.
4
-
-
All as per item No.1 here-in-above, but but capacity 125 to 150 kVAr
4
-
-
All as per item No.1 here-in-above, but but capacity 150 to 200 kVAr
4
-
-
All as per item No.1 here-in-above, but but capacity 250 to 750 kVAr
1
-
-
Disconnection and removing the old unserviceable power factor capacitors from the APFC Panel and Supply and fix Power capacitor cylidrical type Resin filled heavy duty 440 V, 50 Hz ,AC having of capacity 10 KVAR capacities Make : L&T /Crompton / C & S
4
-
-
All as per item No.39 here in above but of capacity 15 KVAR, 440 V,Three phase
3
-
-
All as per item No.39 here in above but of capacity 25 KVAR, 440 V,Three phase
2
-
-
All as per item No.39 here in above but of capacity 50 KVAR, 440 V,Three phase
2
-
-
All as per item No.39 here in above but of capacity 100 KVAR with ssheet metal enclosure type Three phase
1
-
-
Supply and fixing on load change over switches 4 pole in sheet steel enclosure of 160 amps complete all as specified and directed
2
-
-
All as per Ser Item No 44 here-in-above, but250 Amps rating
2
-
-
All as per Ser Item No 44 here-in-above, but200 Amps rating
2
-
-
All as per Ser Item No 44 here-in-above, but400 Amps rating
1
-
-
Disconnection and removing the u/s Main contactor carefully from voltage stabilizer/AMF panel of upto 750 KVA and S&F new main power contactor, coil voltage 240 volt comprising of all accessories suitable for 750 KVA voltage stabilizer.
1
-
-
Disconnection and removing the u/s Main contactor carefully from voltage stabilizer 400 KVA and S&F new power contactor 3 POLE MNX 325, coil voltage 240 volt comprising of all accessories suitable for 400 KVA voltage stabilizer.
1
-
-
Disconnection and removing the u/s Main contactor carefully from voltage stabilizer 300 KVA and S&F new power contactor 3 POLE MNX 265, coil voltage 240 volt comprising of all accessories suitable for 300 KVA voltage stabilizer.
1
-
-
Disconnection and removing the u/s Main contactor carefully from voltage stabilizer 200 KVA and S&F new power contactor 3 POLE MNX 225, coil voltage 240 volt comprising of all accessories suitable for 200 KVA voltage stabilizer.
2
-
-
Disconnection and removing the u/s Main contactor carefully from voltage stabilizer 125 KVA and S&F new power contactor 3 POLE MNX 95, coil voltage 240 volt comprising of all accessories suitable for 125 KVA voltage stabilizer.
2
-
-
Disconnection and removing the u/s Main contactor carefully from voltage stabilizer 100 KVA and S&F new power contactor 3 POLE MNX 80, coil voltage 240 volt comprising of all accessories suitable for 100 KVA voltage stabilizer.
2
-
-
Disconnection and removing the u/s PCB Unit from Servo stabilizer of capacity 750 KVA carefully and S&F new PCB unit complete of same size and capacity suitable for existing 750 KVA Servo Stabilizer all as specified and directed.
2
-
-
All as per item No 54 here-in-above but of capacity 400 KVA
2
-
-
All as per item No 54 here-in-above but of capacity 300 KVA
1
-
-
All as per item No 54 here-in-above but of capacity 200 KVA
1
-
-
All as per item No 54 here-in-above but of capacity 125 KVA
2
-
-
All as per item No 54 here-in-above but of capacity 100 KVA
2
-
-
All as per item No 54 here-in-above but of capacity 22.5 KVA
2
-
-
All as per item No 54 here-in-above but of capacity 10 KVA
2
-
-
Disconnecting and Removing LT Cable connections from Isolation Transformer and transporting to the local work shop, removing the unserviceable / burnt out copper winding wire from the Isolation Transformer of capacity 400 KVA upto 750 KVA (oil cooled), Three Phase 415 V/415 V, rewinding the same with fine enamelled bare copper conductor of same gauge, turns, weight, having Class - H insulation level, keeping the core and windings into the hot air oven till the moisture evoporates and replace the same in its original position, re-installing in this location, connecting existing LT cables and testing complete all as directed by Engineer in Charge at site. Note: Rates Quoted shall deemed to be inclusive of all misc consumable items such as Cotton tape, warnishing, impregnated paper etc. for satisfactory completion of job.
1
-
-
All as per item No 62 herein above but of capacity 45 KVA to 300 KVA
2
-
-
Isolated/de-energize the supply to the LT Panel Board of capacity ranging from 200 Amps to 2000 Amps and voltage 415 Volts/230 Volts, opening the doors/covers of the cubicle enclosure for carrying out servicing / maintenance / repairs of the Panel Board, switchgear, metering etc and re-fixing the same in place after servicing / maintenance / repairs including testing and commissioning of the panel board comprising of the following:-
a) Cleaning inside switchgear chambers and removing dust, carbon and rusted surfaces with blower and apply insulating varnish.
b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. c) Tightening of all bus bar connections, cable connections, replace bolt, nuts wherever required.
d) Repair/welding rates deemed to incl in the loosen compartments to close properly. Note : i) Contractor has to inspect the site before quoting. Any modifications/frame work and renewal if required shall deemed to be included in the quoted rates. ii) Other Spares will be measured and paid under relevant items of schedule
13
-
-
M&L for repair/welding jointing of mild steel hinges and make good of switchgear compartments and painting LT panel board shutters incl welding, riveting and make good the LT panel, excavating and levelling complete LT panel surrounding area complete all as specified and as directed.
11
-
-
S&F Digital ammeter of suitable rating for the LT PB's with built in selector switch of size 96mmx96mm with suitable CT's and connected control wiring complete all as specified and as directed by Engr-in-Charge.
5
-
-
S&F Digital Volt meter 0-500 V with built in selectror switch of size 96mmx96mm along with and connected control wiring complete all as specified and as directed by Engr-in-Charge.
5
-
-
S&F Indicating lamp 240 volts LED type complete all as specified and as directed by Engr-in-Charge.
15
-
-
Material and labour for disconnecting faulty/burnt end portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of incoming and out going cables at panel boards and preparing fresh terminals with suitable size of thimbles, lugs and glands or gland plates as suitable of any size and number of cables incoming out going to panel board`
10
-
-
Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 630 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising of following and including: Incoming
(a) MCCB, 4 Pole, 415 Volts, 400 Amp, 36 KA breaking capacity -01 No
(b) Alum bus bar 630 Amp TPN -01 Set
(c) Digital Voltmeter 0-500 volts with selector switch - 01 No (d) Digital Ammeter 0-200 Amp with selector switch - 01 No
(e) Indicator lamp LED type (R,Y,B) complete with bakalite fuse fitting - 01 Set
Outgoing
(a) MCCB 3 pole, 320 Amp, 36KA, 415 V AC - 03 Nos
(b) MCCB 3 pole, 200 Amp, 25KA, 415 V AC - 02 Nos
(c) Provision for space to be kept blank for fixing of 01 No MCCB.
1
-
-
Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 630 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising of following and including: Incoming
(a) MCCB, 4 Pole, 415 Volts, 400 Amp, 36 KA breaking capacity -01 No
(b) Alum bus bar 630 Amp TPN -01 Set
(c) Digital Voltmeter 0-500 volts with selector switch - 01 No (d) Digital Ammeter 0-200 Amp with selector switch - 01 No
(e) Indicator lamp LED type (R,Y,B) complete with bakalite fuse fitting - 01 Set
Outgoing
(a) MCCB 3 pole, 320 Amp, 36KA, 415 V AC - 03 Nos
(b) MCCB 3 pole, 200 Amp, 25KA, 415 V AC - 02 Nos
(c) Provision for space to be kept blank for fixing of 01 No MCCB.
1
-
-
M&L for preparation old painted surfaces of LT steel tubular pole upto 9mtr long including clamps, brackets, chanel, cross arms, bracing support, pipe of support for cable and swan neck etc applying aluminium paint, zebra painting at bottom of pole up to 1.5 mtr from the PCC coping, writing pole No with specified paint, including white wash on coping after carrying out minor repairs to cement plaster complete all as specified and directed. Note: Pole number shall be marked with enamel paint over a base on pole surfaces.
200
-
-
M&L zebra painting at bottom up to 1.5 mtr from the coping of RCC pole, writing pole No with specified paint, applying white wash on coping after carrying out minor repairs to cement plaster complete all as specified and directed.
150
-
-
Supply and errection swaged steel tubular poles, 410 SP-31, 9.0 m long with cast iron base plate, taper plug, bolts,nuts & screws, painting with aluminium paint and zebra painting as directed, including taking down the old unserviceable poles, complete all as directed by Engineer-in-Charge.
5
-
-
M&L for plain cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass comcrete complete all as specified.
1.8
-
-
M&L for providing plaint cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate as in foundation, roof, kerb or mud stops, rounded or chamfered on edges and coping to pole, including necessary formwork as required complete all as specified.
1.01
-
-
Supply, fixing and streching of Aluminium conductor steel rainforced (ACSR) of required size or guage on LT/HT poles fixed on insulators and binding with & including binding wire complete all as specified and directed by Engineer-in-charge.
1
-
-
Supply and fix stay assembly complete with accessories as shown in electrical plate No. 1 of SSR Part I for LT poles with 16 mm dia stay rod including excavation,PCC work and connected stay assembly accessories such as stay rod, insulator, clamps etc., complete all as specifed and directed.
10
-
-
Supply and fix in replacement of cradles, hexagonal/rectangular, fabricated with Galvanised steel wire 3.15 mm or 4 mm dia for span 40-45 m between poles, cross wire of intervels of 1m duly binding for LT/HT guard wire and craddles of required size or span complete all as specified and directed by Engineer-in-charge.
40
-
-
S&F in replacement of pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as sprcified and as directed.
20
-
-
S&F in replacement of shackle type, porcelain, vitreous, white, brown or green insulator 1100 Volts LT of size 100 mm high and 115 mm dia including galvanised mild steel straps of size 31x5 mm, washers, insulator bolts 14 mm dia, washers and nuts etc complete all as sprcified and as directed.
12
-
-
S&F in repair loop type insulator, vitreous porcelain, white brown or green small size with overall dimensions 65x90 mm clearance of hole 16 mm dia complete all as specified and directed by Engineer-in-charge.
8
-
-
S&F in replacement of galvanised stay wire with stay strand 7/4mm for 9 m height poles duly replacing with loop insuolator and sleeve, U clamp incl nut, bolts and washers complete all as specified.
20
-
-
M&L for cutting/trimming of branches of tree tuching/approaching LT/HT over lines of various spans (having 40 to 45 mtr) up to 3 m width on each side using cutting equipments hacksaw, axe, ladders, rope and safety measures etc including disposal of trimmed branches 100 m away inside the cantonment area and cleaning the ares complete all as specified and directed by Engineer-in-charge.
200
-
-
M&L for re-stretching of loose LT/HT over head line, aluminium conductor, GI guard wires and credals etc complete at various location and different span of 2 to 7 conductors with the help of rope and pullar, provision of short length of conductors as jumpers, duly binding with existing insulators etc complete all as specified and directed by Engineer-in-charge.
200
-
-
M&L for fabrication of cross arms bracings supports, clamps and back plates, iron stainer, water gate, ladder for clear water tank etc as required structural steel section including nuts, bolts, washers, welding,bending, cold or hot, drilling holes for bolts in any shape or size and including of one coat of primer and one under coat and one finishing coat of paint complete all as specified and as directed by Engr in charge.
Note: Exposed steel surface shall be treated with two coats of aluminium paint over a coat of red oxide primer and unexposed surface of steel sectioons shall be appied one coat of red oxide primer, the quoted rate shal be deemed inclusive of the above provn.
0.5
-
-
Taking out faulty underground 1100 volt grade LT cable of different sizes upto 300 sqmm 3.5 core/4 core by excavation and removing bricks/covers of any size and relaying in the same trenches or rerouting after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed.
Note:
i) New LT cable required to replace fault portion, joints will be measured and paid separately under respective items of the schdule.
ii) Retrived serviceable bricks / PCC cover shall be laid in trenches for cable protection. In case extra cable covers and sand are required at site; same shall be measured and paid separately under respective items of the schdule.
iii) Earthwork and excavation will be measured and paid separately under respective items of the schdule.
1200
-
-
S&F 1.5 sqmm 3 core, 1100 volt grade heavy duty cable, PVC insulated PVC sheathed, multistranded copper conductor cable connecting street light fitting from FRP junction box/OH line to street lights complete all as specified and directed
120
-
-
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty copper conductor cable of size 2 core 10 sqmm (nominal cross section in service connections of PVC insulated aluminium multi standard conductor served with an inner sheathing of PVC tape and overall PVC sheathed) complete all as specified and directed by Engr-In-charge.
120
-
-
All as per Item No 89 here-in-above, but cable of 2 core 6 sqmm complete all as specified and as directed by Engineer-in-Charge.
120
-
-
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core and including provision of gland plates, gland and aluminium lugs to bothe ends of cable connections complete all as specified
100
-
-
All as per Sl item No 91 here-in-above, but cross-sectional area of cable 16 sq mm 2 core
100
-
-
All as per Sl item No 91 here-in-above, but cross-sectional area of cable 25 sq mm 2 core
100
-
-
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cable cross-sectional area 6 sq. mm 4 core and including provision aluminium lugs to bothe ends for cable connections and taking down old US cable, complete all as specified
90
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 10 sq. mm 4 core
100
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 16 sq. mm 4 core
100
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 25 sqmm 4 core
100
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 35 sqmm 3.5 core
100
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 50 sqmm 3.5 core
100
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 70 sqmm 3.5 core
100
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 95 sqmm 3.5 core
120
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of120 sqmm 3.5 core
120
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 150 sqmm 3.5 core
120
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 185 sqmm 3.5 core
100
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 240 sqmm 3.5 core
80
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of 300 sqmm 3.5 core
80
-
-
All as per Sl Item No 94, here-in-above, but cable cross section area of400 sqmm 3.5 core Note for sl Item Nos 94 to 107 : Excavation, earthwork and cable protection works will be measured and paid for separately.
80
-
-
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil.
303.75
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm.
77.75
-
-
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
226
-
-
M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover. Note: Only punned thickness will be considered for measurement purpose
121.5
-
-
M&L for cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for laying cable protection pipes complete all as specified and as directed by Engineer-in-Charge.
1
-
-
Removing unserviceable PCC cable covers, Supply and laying new M-20 grade unreinforced pre- cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection, made out of , etc complete.
7500
-
-
Relaying old serviceable unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection complete. Note : Old serviceable cable covers obtained while taking out cables shall be re-used under this item.
1500
-
-
Removing unserviceable LT OH line jumpers / connectors / taps / sleeves / insulators of any type and size; rejumpering the same by supply and fixing suitable size of ACSR conductor as jumpers, replacing serviceable insulators and testing the OH lines after carrying out repair / replacement / maintenance of jumpers all as specified and directed by Engineer-in-Charge.
Note: Quoted rate shall include for :-
i) Jumpers set of two to Six to be replaced in one job at one pole point. ii) Supply of Insulators will be measured and paid separately under relevent item of the schedule.
50
-
-
S&F PVC line separator suitable for 3 phase 4 wire and 02 wire of street light of LT line all as directed.
20
-
-
Supply and fix self adhesive reflective radium stickers 75 mm wide around the street light poles 1.5 m above ground level complete all as specified and directed.
30
-
-
M&L for replacing unserviceable Straight through cold shrink cable joint 1100 Volt complete with new cable jointing kit along with accessories suitable for 6 to 25 Sqmm 2 Core complete all as specified and as directed.
3
-
-
M&L for replacing unserviceable Straight through cold shrink cable joint 1100 Volt complete with new cable jointing kit alongwith accessories suitable for 10 to 50 Sqmm 3.5 Core complete all as specified and as directed.
3
-
-
M&L for replacing unserviceable Straight through cold shrink cable joint 1100 Volt complete with new cable jointing kit alongwith accessories suitable for 70 to 150 Sqmm 3.5 Core complete all as specified and as directed.
3
-
-
M&L for replacing unserviceable Straight through cold shrink cable joint 1100 Volt complete with new cable jointing kit alongwith accessories suitable for 185 to 400 Sqmm 3.5 Core complete all as specified and as directed.
2
-
-
S&F cable end jointing kit for LT, 1100 Volt (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 to 50 sqmm with provision of lugs/thimbles/aluminium jumpers for OH/UG connections complete all as specified and as directed by Engineer-in-Charge.
6
-
-
All as per Serial Item No 122 here-in-above, but for cable of cross sectional area of 70 sqmm to 95 sqmm
3
-
-
All as per Serial Item No 122 here-in-above, but for cable of cross sectional area of 120 sqmm to 150 sqmm
3
-
-
All as per Serial Item No 122 here-in-above, but for cable of cross sectional area of 185 sqmm to 240 sqmm
3
-
-
All as per Serial Item No 122 here-in-above, but for cable of cross sectional area of 300 to 400 sqmm
3
-
-
Disconnecting of LT supply, opening cable box chamber of outdoor / indoor LT panel, removing of burnt out lugs, LT switch gears / MCCB / MCB of any capacity and size and cleaning of bus bar and terminals with CTC solutions, insulating the bus bar by taping color codes and making connections complete with necessary nut, bolt, washeres, thimbles and links of existing size and refixing all switchgears after repair / maint / servicing and welding the hinges/doors complete all as specified and directed.
5
-
-
M&L for removing connections of faulty cable from both ends of LT terminaton from panel / transformer after meggaring and detecting faulty cable, finding cable fault spot with any mechanism like cable fault locator or manual carrying out excavation, removing the faulty / burnt cable from the trench and jointing cable for serviceable condition checking by meggaring including shifting the cable for relaying all as specified and directed by Engr-InCharge.
Note: i) Excavation and earthwork, relaying cables and cable protection works will be measured and paid seperately ii) Skilled operator & instruments involved for detecting the cable fault shall deemed to be included in the quoted rate.
5
-
-
Supply and fix in repairs GI Steel tubing light grade of 40mm dia along with fittings in trenches/wall for cable protection complete all as specified and directed.
12
-
-
All as per Serial Item No 129 here-in-before, but pipe of 50mm dia/ bore.
12
-
-
All as per Serial Item No 129 here-in-before, but pipe of 80 mm dia/ bore.
12
-
-
Taking down the care fully existing out door/indoor type Old PCC floor mounted LT panel board of size (1.0m,x1.0m to 2.0x1.5m of any width) after disconnecting all type of incoming and out going cables, removing carefully switchgears and measuring instruments for reuse/refixing of serviceable items and repair / maint / servicing the existing panel by replacing hinges, switchgear compartments with rubber seal, locks, nuts, bolts and washers and provn of danger notice boards, insulation sleeves with colour coding, painting with two coats of powder coating, and finally reconnecting all cables, fixing panel board in same position with suitable aluminium lugs, nut bolts and washers, refixing serviciable switchgears obtained from the panel. Note: Supply of Switchgears will be measured and paid separately
2
-
-
M & L for preparation of old painted surfaces of LT panel size (1.0m,x1.0m to 2.0x1.5m of any width) and applying spray painting with two coats of synethetic enamel paint over a coat of red oxide primer of existing color for outdoor/indoor panel board, outer & inner side and scraping out the old paint surfaces of existing panel boards complete all as directed by Engineer-in-charge including white wash to panel foundation/PCC base complete all as specified and directed.
3
-
-
Supply and fix in repairs, digital voltmeter 0 - 500 Volts
3
-
-
Supply and fix in repairs, digital ammeter 0 - 500 Volts
3
-
-
Supply and fix in repairs, neon indicating lamp (Red, Yellow, Blue)
10
-
-
Supply and fixing MCCB TPN/TP 315 Amps 415 Volts of braking capacity 36 KA of 4 pole confirming to complete taking down old unserviceable one and making necessary connections including all provisions for fixing in panel compartments as existing using necessary links,lugs of suitable size and cleaning the terminals with CTC solutions complete all as specified and directed. Make : Havells/Legrand/IndoAsian (optimum 2.0)/Schneider/HPL/Standard
2
-
-
All as per Ser Item No 137 here-in-above, but of 250 Amps with breaking capacity 25 KA.
2
-
-
All as per Ser Item No 137 here-in-above, but of 200 Amps with breaking capacity 25 KA.
3
-
-
All as per Ser Item No 137 here-in-above, but of 125 Amps with breaking capacity 25 KA.
2
-
-
All as per Ser Item No 137 here-in-above, but of 630 Amps with breaking capacity 50 KA.
2
-
-
All as per Ser Item No 137 here-in-above, but of 400 Amps with breaking capacity 36 KA.
2
-
-
All as per Ser Item No 137 here-in-above, but of 500 Amps with breaking capacity 50 KA.
2
-
-
Suuply and fixing on load change over switch 4 pole in sheet steel enclosure panel of 160 amps complete all as specified and directed
2
-
-
All as per Ser Item No 144 here-in-above, but of 250 Amps rating
2
-
-
All as per Ser Item No 144 here-in-above, but of 200 Amps rating
2
-
-
All as per Ser Item No 144 here-in-above, but of 400 Amps rating
1
-
-
Demolishing the broken earth pit chamber and constructing new earth pit chamber and PCC chamber cover duly repair and maint of the existing earth of any type to obtain permissible value complete all as specified
10
-
-
Materla and labour for disconnecting faulty/burnt end portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of incoming and out going cables at panel boards and preparing fresh terminals with suitable size of thimbles,lugs of suitable size to connecting cables and clean/levelling soil around panel board complete all as specified.
7
-
-
Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel (CPRI approved), single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 630 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated, locking should be screw type, mechanical type, interlocking, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising and including of following : -
Incoming
(a) MCCB, 4 Pole, 415 Volts, 400 Amp, 36 KA breaking capacity -01 No
(b) Aluminium bus bar 630 Amp TPN -01 Set
(c) Digital Voltmeter 0-500 volts with selector switch - 01 No (d) Digital Ammeter 0-200 Amp with selector switch - 01 No
(e) Indicator lamp LED type (R,Y,B) complete with bakelite fuse fitting - 01 Set
Outgoing
(a) MCCB 3 pole, 320 Amp, breaking capacity of 36KA, 415 V AC - 03 Nos
(b) MCCB 3 pole, 200 Amp, breaking capacity of 25KA, 415 V AC - 02 Nos
(c) Provision for space to be kept blank for fixing of 01 No MCCB.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%