Military Engineer Services Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date8 Nov 2018
Closing Date4 Dec 2018
Tender Amount₹ 37,00,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(c) Drain water Lifting pump HP-1.5 ,Head- 11.5mtr discharge - 10 Cum/hr, Make-Kishor pumps coupled with Induction motor 3 phase, 415 volts, RPM-1450, HP-1.5, Make- Crompton Greaves - 2 Nos.

-

-

-

... More
(d) Main Electric control panel 630 Amp SFU with starters, push buttons,selector switches,volt & Amp meters,control wiring & accessories local push button stations -1 set

-

-

-

... More
(e) Starters for motor - 04 Nos

-

-

-

... More
(f) 100 KVA DG Set -01 Nos

-

-

-

... More
(g) GLR of 2x350 cum of capacity -01 Nos

-

-

-

... More
(h) C.I./ D.I.piping Network with sluice valves -02 set

-

-

-

... More
Manning and Operation of Fire pump house Installation at NK Bail (NAD Area) in 03 (three) shifts of 8 hours each on all days including Sundays and holidays including minor maintenance / checks, all as specified and directed by Engineer-in-Charge. The installation comprises the equipments same as mentioned in item No.1.01 to 1.08 herein above.

11

-

-

... More
Notes for item No 1 & 2 above :- (a) Contractor has to employ minimum following staff for manning & operation of fire water pump house installations at Sl item Nos 1 & 2 above :-

-

-

-

... More
(i) One No skilled Fitter general mechanic operator per shift of 08 hours (Total 06 shifts per day i.e 3 shifts per day for each fire pump house installation at Sl No. 1 &2 above) havining minimum ITI qualification in respective trade from Govt recognised institute with adequate knowledge with minimum two years experience in maint & operation of water supply installation.The operator must be competent to carry out the minor Maint of water supply installation all as directed by Engr-in-charge. (ii) One No skilled Valve operator per shift of 08 hours (Total 06 shifts per day i.e 3 shifts per day for each fire pump house installation at Sl No 1 & 2 above) having minimum ITI qualification in respective trade from Govt recognised institute with adequate knowledge with minimum two years experience in maint & operation of water supply pipes & valves. The operator must be competent to carry out the minor maint of water supply pipe line & valves all as directed by Engr-in-charge. (iii) The contractor shall pay the wages to the Fitter general mechanic /Valve operators (as applicable) through e payment i.e Aadhar linked bank accounts(Credit to their bank account). Engr-in-Charge shall ensure that e-payment made to Fitter general mechanic /Valve operators and their wages shall not be less than minimum wages fixed by state Govt or central Govt whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Engineer-in-Charge and the same shall be kept in record duly verified. (iv) It is responsible of contractor to deposit the employees provident fund (EPF) to the connected authority as per the prevailing scales as laid down by the Ministry of labour for all Electrician/operator/helper (as applicable) and necessay proof to this regard shall be submitted to GE for verification and records. The quoted rate shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, shall be liable for action as deemed fit. Decision of GE in this regard shall be final and binding. (v) The contracotr shall maintain all the registers under various labour law rules, 2017 and shall be produced to GE and as well as officers detailed by labour department. (vi) Cost of routine maintenance spares will be measured and paid separately under respective item here in after. However cost of labour is deemed to be included in the unit rate quoted above.

-

-

-

... More
(b) Each shift duration shall be 08 hours & duty timing will be decided by Engr- in-Charge. (c) The unit rate quoted shall be deemed to include for daily minor maintenance like checking and rectification of any water leakage ,loose connection,cleaning and general up keep of pump room/ GLR/HTR and area around it (d) Power supply for operating the installation will be made available by the department free of cost. (e) The Contractor shall not employ same tradesman continuously for more than 11 months during the Contract period. (f) In case of failure due to absence of operative staff, the contractor shall be liable to pay compensation at twice the cost of a day’s Manning & Operation derived from pro rata rate of Sch ‘A’ quoted rates.

-

-

-

... More
(g) The unit rate quoted shall deemed include for maintenance of earthpits, cutting & removing of vegitation and upkeep of the surrounding area, all around the bldg upto 6m from the plinth protection all as directed by Engr-in-Charge. In case of failure, a penalty of Rs 2000/- per month will be levied and recovered from dues. (h) The contractor shall provide 02 uniforms to each operator and design of uniform shall be got approved. In case of failure, a penalty of Rs 1200/- per uniform will be levied and recovered from dues. (j) The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (Gum boots-02 pairs, hand gloves), a penalty of Rs 3000/- will be recovered and levied (k) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maint is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly.

-

-

-

... More
Sch 'A' Part II : MAINT OF EXTERNAL WATER SUPPLY PIPELINE AT SITE ‘E’ & AMDALLI

-

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil for laying/taking out GI pipe line all as specified and directed.

40

-

-

... More
Returning filling in including spreading levelling watering and well ramming in layer not exceeding 25 cm thick in soft/loose soil all as specified and directed.

30

-

-

... More
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.

10

-

-

... More
Taking out old GI tubing with all fittings from trenches, walls, floors etc of following sizes all as directed (Excavation & earth work will be measured & paid seperately under respective item) :-

-

-

-

... More
(a) 50 mm bore

100

-

-

... More
(b) 40 mm bore

80

-

-

... More
(c) 32 mm bore

80

-

-

... More
(d) 25 mm bore

100

-

-

... More
(e) 20 mm bore

100

-

-

... More
Fixing only, testing in new or old position in wall, ceiling, floor GI tubing obtained from item No 7.01 (a) to 7.05 (e) herein before including cleaning of pipe and provn of new fittings such as bends, elbwos, tees sockets etc all as directed by Engineer-in-charge for the following sizes:-

-

-

-

... More
(a) 50 mm bore

20

-

-

... More
(b) 40 mm bore

20

-

-

... More
(c) 32 mm bore

20

-

-

... More
(d) 25 mm bore

25

-

-

... More
(e) 20 mm bore

25

-

-

... More
Laying only, testing in new or old position in trenches, GI tubing obtained from item No 7.01 (a) to 7.05 (e) herein before including cleaning of pipe and provn of new fittings such as bends, elbwos, tees sockets etc all as directed by Engineer-in-charge for the following sizes:-

-

-

-

... More
(a) 50 mm bore

20

-

-

... More
(b) 40 mm bore

20

-

-

... More
(c) 32 mm bore

20

-

-

... More
(d) 25 mm bore

20

-

-

... More
(e) 20 mm bore

25

-

-

... More
Fixing only, testing GI tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and directed for the following sizes (G I pipe shall be issued under sch 'B' free fixing only).

-

-

-

... More
(a) 50 mm bore

30

-

-

... More
(b) 40 mm bore

20

-

-

... More
(c) 32 mm bore

20

-

-

... More
(d) 25 mm bore

35

-

-

... More
(e) 20 mm bore

25

-

-

... More
Laying only, testing GI tubing medium grade galvanised with all fittings and laid in trenches all as specified and directed for the following sizes( G I pipe shall be issued under sch 'B' free fixing only):-

-

-

-

... More
(a) 50 mm bore

30

-

-

... More
(b) 40 mm bore

20

-

-

... More
(c) 32 mm bore

20

-

-

... More
(d) 25 mm bore

20

-

-

... More
(e) 20 mm bore

25

-

-

... More
Supply and fix in repairs gun metal/bronze gate valve ISI marked with iron wheel head screwed both ends for iron pipe of the following sizes all as specified and directed:-

-

-

-

... More
(a) 50 mm bore

5

-

-

... More
(b) 40 mm bore

5

-

-

... More
(c) 32 mm bore

8

-

-

... More
(d) 25 mm bore

15

-

-

... More
(e) 20 mm bore

10

-

-

... More
Supply and fix in repairs ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 25 mm bore (Minimum weight-455gms) .

180

-

-

... More
Supply and fix in repairs ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (Minimum weight-210gms) .

100

-

-

... More
M&L for removing all scale and dirt etc from PVC tanks and from mouths of circulating pipes etc and cleaning tank by using sodium hyphochloride gel to remove bacteria etc including cost of writing letters "Tank cleaned on (____ Date)" using synthetic enamel paint out side the tank of PVC water tanks 500 litres capacity completed all as directed.

52

-

-

... More
All as per Item 15 here in before but of capacity 1000 ltr complete

415

-

-

... More
All as per Item 15 here in before but of capacity 2000 ltr complete

6

-

-

... More
All as per Item 15 here in before but of capacity 5000 ltr complete

10

-

-

... More
Supply and fix in repairs PVC water tank cover of existing make suitable for 500 ltrs capacity with fixing PVC hinges, bolts & locking arrangement etc complete all as specified and directed.

100

-

-

... More
Supply and fix in repairs PVC water tank cover of existing make suitable for 1000 ltrs capacity with fixing PVC hinges, bolts & locking arrangement etc complete all as specified and directed.

100

-

-

... More
S&F in repairs rotational moulded polyethylene water storage tanks 500 litres capacity double layered, ISI Marked (cylindrical vertical with closed top), having locking arrangement, hoisted and fixed in position all as specified and directed

2

-

-

... More
S&F in repairs rotational moulded polyethylene water storage tanks 1000 litres capacity double layered, ISI Marked (cylindrical vertical with closed top), having locking arrangement, hoisted and fixed in position all as specified and directed

5

-

-

... More
S&F in repairs rotational moulded polyethylene water storage tanks 2000 litres capacity double layered, ISI Marked (cylindrical vertical with closed top), having locking arrangement, hoisted and fixed in position all as specified and directed

1

-

-

... More
M & L for repairs to sluice valves of size 150 mm by taking out defective spindle, repairing the same in lathe by grinding, turning, cutting to make fresh grooves and refix the same in its original position and testing for leakage all as specified and directed.

1

-

-

... More
M & L for repairs to sluice valves of size 200 mm by taking out defective spindle, repairing the same in lathe by grinding, turning, cutting to make fresh grooves and refix the same in its original position and testing for leakage all as specified and directed.

1

-

-

... More
M&L for repair to fire Hydrant Valves of size 100 mm dia and shifting at civil workshop by transport, opening up the defective Valves and taking out spindle and gate from sluice valve and removing the old threads by grinding and making a new threads by brass welding, turning & polishing to the spindle at civil workshop on grinding machine as per original threads and refixing the same at position and testing complete all as specified and directed

4

-

-

... More
S & F in repairs gland packing of fire hydrant valves complete all as specified and directed.

10

-

-

... More
S & F in repairs cast iron spindle wheel of grade FG 200 as per IS 210 for fire hydrant valve complete all as specified and directed.

8

-

-

... More
M & L for overhauling of three phase, 415 volts monoblock / split casing centrifugal type pump set by removing from connected pipes & electric connections etc & dismantling pump/opening up the pumpset, cleaning inside & out side thoroughly, replacing the parts such as gland packing set, rubber insertion, gun metal bushes, bearing,water seal packing etc, cleaning of impeller, greasing etc complete and re-assembling, re-fixing on original position with packing, necessary nut bolts etc including testing for smooth functioning etc of following capacities all as specified and directed :-

-

-

-

... More
Main fire water Pump of capacity 273 Cum/hr at MTP & NAD area Make : Kirloskar

1

-

-

... More
Diesel engine driven Pump of capacity 273 Cum/hr at MTP & NAD area Make : Kirloskar

1

-

-

... More
Clarified drinking pump of capacity 200 cum/hr vertical turbine type. Make : Kirloskar

1

-

-

... More
Jockey Pump of capacity 30 Cum/hr at MTP & NAD area Make : Kirloskar

2

-

-

... More
M & L for taking down, transportation to to workshop, dismantling electric motor of any make three phase 415 volts, opening the motor, cutting/removing the existing burnt winding and rewinding using super enamelled copper wire of suitable gauge to match with the existing winding including varnishing & drying and re assembling the motor, connecting with pumpset with proper alignment and testing complete all as specified and directed of following capacities :-

-

-

-

... More
(a) 30 HP capacity

1

-

-

... More
(b) 1.5 HP capacity

1

-

-

... More
M & L for cleaning of RCC Ground level reservoir of Fire water pump house of 2X350 cum (7,00,000 litres) capacity including mouths of connected pipes etc by dewatering the reservoir by using a portable pumpset of suitable capacity, removing all sludge/mud/dirt etc manually, pouring fresh water in reservoir through another pumpset, rinsing and dewatering the reservoir including removing sludge/dirt particle manually, wash the reservoir using fresh water mixed with sodium hypochlorite & drain out water by a pumpset and finally applying one coat of antibacterial sodium hypochlorite solution to inner surface & writing details of cleaning in prescribed format complete all as specified and directed.

1

-

-

... More
M & L for cleaning of RCC over head tank reservoirs of fire/drinking water at NAD/MTP area of 3,00,000 litres capacity including cleaning mouths of connected pipes etc by dewatering, removing all sludge/mud/dirt etc manually, pouring fresh water using pumpset of suitable capacity, rinsing and dewatering including removing sludge/dirt particle manually, wash the complete tank using fresh water mixed with sodium hypochlorite & drain out water by a pumpset, cleaning complete inlet & outlet pipes and finally applying one coat of antibacterial sodium hypochlorite solution to inner surface & writing details of cleaning in prescribed format complete all as specified and directed.

2

-

-

... More
M & L for cleaning of RCC static water tank of 275 cum (2,75,000 litres) capacity including mouths of connected pipes etc by dewatering the tank by using a portable pumpset of suitable capacity, removing all sludge/mud/dirt etc manually, pouring fresh water in tank through another pumpset, rinsing and dewatering the tank including removing sludge/dirt particle manually, wash the tank using fresh water mixed with sodium hypochlorite & drain out water by a pumpset and finally applying one coat of antibacterial sodium hypochlorite solution to inner surface & writing details of cleaning in prescribed format complete all as specified and directed.

5

-

-

... More
M & L for preparation of existing painted surfaces of pressure sand filters, air compressors, motor, pump,water pipe lines etc at ground level drinking water pump house and filling of cavities etc and applying one coat of synthetic enamel paint using spray gun/machine as per colour code including writing SM & MES No on pump & motor, indication marking etc complete all as specified and directed.

1

-

-

... More
S&F in repairs MCCB 4 Pole, 100 Amps, 415 V, Rupturing capacity 36 KA in existing panel and connected to bus bar all as specified and directed. Make:- LEGRAND Cat No. 4200 95 or equivalent in makes as specified herein after complete all as specified and directed.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.