Military Engineer Services Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date30 Nov 2024
Closing Date18 Dec 2024
Tender Amount₹ 23,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Inspection, maintenance and servicing of DG set 320 KVA installed at SDI Power house Set No. 2 including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge.

2

-

-

... More
Inspection, maintenance and servicing of DG set 320 KVA installed at ASTE MT AREA including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge.

2

-

-

... More
Inspection, maintenance and servicing of DG set 275 KVA installed at ASTE POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge.

2

-

-

... More
Inspection, maintenance and servicing of DG set 250 KVA installed at IAM POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge.

2

-

-

... More
Inspection, maintenance and servicing of DG set 200 KVA installed at ASTE TP SCHOOL including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge.

2

-

-

... More
Inspection, maintenance and servicing of DG set 125 KVA installed at VISHWA VIHAR POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions /OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge.

2

-

-

... More
Inspection, maintenance and servicing of DG set 125 KVA installed at AKASH VIHAR POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge.

2

-

-

... More
Inspection, maintenance and servicing of DG set 82.5 KVA installed at VAYU VIHAR POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge.

2

-

-

... More
Inspection, maintenance and servicing of DG set 75 KVA installed at 26 ED POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge.

2

-

-

... More
Inspection, maintenance and servicing of DG set 75 KVA installed at 26 ED POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 63 KVA installed at AV CAMP POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 62.5 KVA installed at 26 ED POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 62.5 KVA installed at 26 ED POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 62.5 KVA installed at IAM POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 62.5 KVA installed at VAYU VIHAR OFFICER'S MESS including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions /OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 40 KVA installed at M P camp including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 40 KVA installed at SDI POWER HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 25 KVA installed at 26 ED including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 25 KVA installed at SMC MP CAMP including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Inspection, maintenance and servicing of DG set 15 KVA installed at VAYU VIHAR PUMP HOUSE including Alternator, excluding AMF panels connected to DG sets for routine check up (B-check once in 6 months or 300 running hours whichever is earlier) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturers instructions/OEM including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.

2

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 750 KVA DG SET installed at SDI POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 400 KVA DG SET installed at IAM POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 320 KVA DG SET installed at SDI Power house Set No. 1 for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 320 KVA DG SET installed at SDI Power house Set No. 2 for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 320 KVA DG SET installed at ASTE MT Area for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 275 KVA DG SET installed at ASTE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 250 KVA DG SET installed at IAM POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 200 KVA DG SET installed at ASTE SCHOOL for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 125 KVA DG SET installed at VISHWA VIHAR POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 125 KVA DG SET installed at AKASH VIHAR POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 82.5 KVA DG SET installed at VAYU VIHAR POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 75 KVA DG SET installed at 26 ED POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 75 KVA DG SET installed at 26 ED POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 62.5 KVA DG SET installed at AKASH VIHAR POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 63 KVA DG SET installed at 26 ED POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 62.5 KVA DG SET installed at 26 ED POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 62.5 KVA DG SET installed at IAM POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 62.5 KVA DG SET installed at VAYU VIHAR OFFICER'S MES for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 40 KVA DG SET installed at MP CAMP for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 40 KVA DG SET installed at SDI POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 40 KVA DG SET installed at 26 ED POWER HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 25 KVA DG SET installed at SMC MP CAMP for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Servicing & Maintenance of AMF panels (Once in two months) pertains to 15 KVA DG SET installed at VAYU VIHAR PUMP HOUSE for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".

6

-

-

... More
Supply only engine oil SAE 20W-40W Make Volvoline / IOC

800

-

-

... More
Supply and filling radiator coolant Make Volvoline / IOC

350

-

-

... More
Servicing of Self Starter assembly of 24 volt DC suitable for 320 KVA to 750 KVA by disconnecting from engine and dismantling the same, cleaning all accessories, replace the wornout parts like brushes, bushes, contact plates, jumping leads and seals, rewinding/revarnishing the field coil, armature and reassembling the same, refitting to the engine and testing all as directed by Engr-in-Charge.

4

-

-

... More
Servicing of Self Starter assembly of 24 volt DC suitable for 125 KVA to 250 KVA by disconnecting from engine and dismantling the same cleaning all accessories, replace the wornout parts like brushes, bushes, contact plates, jumping leads and seals, rewinding/revarnishing the field coil, armature and reassembling the same,refitting to the engine and testing all as directed by Engr-in-Charge.

4

-

-

... More
Servicing of Self Starter assembly of 12 volt DC suitable for 15 KVA to 82.5 KVA by disconnecting from engine and dismantling the same cleaning all accessories, replace the wornout parts like brushes, bushes, contact plates, jumping leads and seals, rewinding/revarnishing the field coil, armature and reassembling the same,refitting to the engine and testing all as directed by Engr-in-Charge.

8

-

-

... More
Removing the self starter 24 Volt DC from the engine of 125 KVA to 750 KVA DG sets and taking to work shop for rewinding of armature/field including replacement of brush and bush and refixing the same to the engine and testing all as directed by Engr-in-Charge.

6

-

-

... More
Removing the self starter 12 Volt DC from the engine of 15 KVA to 82.5 KVA DG sets and taking to work shop for rewinding of armature/field including replacement of brush and bush and refixing the same to the engine and testing all as directed by Engr-in-Charge.

8

-

-

... More
Supply only 12 V DC stopping solenoid suitable for 15 to 82.5 KVA DG sets.

6

-

-

... More
Supply only 24 V DC energised Stopping solenoid for 125 to 750 KVA DG sets.

6

-

-

... More
Supply only Water Temp gauge with adapter.

4

-

-

... More
Supply only Oil Temp gauge with adapter.

4

-

-

... More
Supply only Oil pressure guage with pipe.

4

-

-

... More
Supply only Diaphragm Coupling for 62.5 KVA to 82.5 KVA DG Sets

3

-

-

... More
Supply only Diaphragm Coupling for 125 KVA DG Sets.

2

-

-

... More
Supply only Diaphragm Coupling for 250 KVA to 750 KVA DG Sets.

3

-

-

... More
Supply only Volt meter DC.

4

-

-

... More
Supply only Ammeter DC.

5

-

-

... More
Supply only Battery 12 volts 180 AH.

5

-

-

... More
Supply only Selector switch 3 way 4 pole

2

-

-

... More
Supply only Volt Meter Selector switch.

2

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 750 KVA DG Set installed at ASTE MT Area.

1

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 320 / 400 KVA DG Set installed at IAM power house set No. 1

1

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 250 / 275 KVA DG Set installed at ASTE.

2

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 200 KVA DG Set installed at ASTE TP SCHOOL

1

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 125 KVA DG Set installed at ASTE POWER HOUSE, VISHWA VIHAR POWER HOUSE & AKASH VIHAR POWER HOUSE.

2

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 82.5 KVA DG Set installed at VAYU VIHAR POWER HOUSE

1

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 62.5 KVA DG Set installed at 26ED POWER HOUSE

1

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 70 KVA DG Set installed at 26ED POWER HOUSE

1

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 62.5 KVA DG Set installed at VAYU VIHAR POWER HOUSE / AV Camp.

1

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 40 KVA DG Set installed at SMC MP CAMP / SDI.

1

-

-

... More
Supply and fix in repairs Air filter element as per existing make for 25 KVA DG Set installed.

2

-

-

... More
Supply Magnetic Relay suitable for 125 KVA Vihar complete all as specified and directed.

1

-

-

... More
Supply and Fix Phase Failur Relay VMRD2 240V AC Minilec make installed at ASTE complete all as specified and directed .

1

-

-

... More
Supply and Fix Mini Contactor 220V installed complete all as specified and as directed .

1

-

-

... More
Supply and Fix Contactor 16A suitable for 320KVA DG Work installed at SDI complete all as specified and directed .

1

-

-

... More
Servicing of radiator assembly of 750 KVA DG SET installed at SDI POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 320 KVA DG SET installed at ASTE MT AREA / SDI SET NO 1 & 2 complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

3

-

-

... More
Servicing of radiator assembly of 400 KVA DG SET installed at IAM POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 275 KVA DG SET installed at ASTE TP SCHOOL complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 200 / 250 KVA DG SET installed at ASTE POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

2

-

-

... More
Servicing of radiator assembly of 125 KVA DG SET installed at VISHWA VIHAR POWER HOUSE / AKASH VIHAR DOMESTIC CAMP complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

2

-

-

... More
Servicing of radiator assembly of 82.5 KVA DG SET installed at VAYU VIHAR POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 75 KVA DG SET installed at 26 ED POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 63 KVA DG SET installed at 26 ED POWER HOUSE complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 63 KVA DG SET installed at VAYU VIHAR OFFICERS MESS complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 62.5 KVA DG SET installed at IAM POWER HOUSE / AKASH VIHAR POWER HOUSE & 26 ED complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

3

-

-

... More
Servicing of radiator assembly of 25 KVA DG SET installed at SMC MP CAMP complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 43.5 KVA DG SET installed at IAM complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 40 KVA DG SET installed at SMC MP CAMP complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 40 KVA DG SET installed at SDI complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Servicing of radiator assembly of 25 KVA DG SET installed at 26 ED / MP CAMP complete including cleaning the radiator, cooling water spaces, inner cooler with appropriate cleaning agent, descaling with scale solvent as well as neutralising agent and arrest leakages by means of brazing, replacing the unserviceable rubber hoses, pipes, circlip, clamps etc, reinstalling and commisioning all as directed by Engr-in-Charge.

1

-

-

... More
Supply and fix Contactor coil for MNX 95 pole contactor coil 230V / 415 AC suitable for 125 KVA to 750 KVA complete all as specified and as directed

1

-

-

... More
Supply and fix Automatic voltage regulator upto 125 KVA complete all as specified and as directed .

1

-

-

... More
Supply and fix Automatic voltage regulator 200 KVA to 320 KVA complete all as specified and as directed .

1

-

-

... More
Dismantling of unserviceable AMF logic controller from Control panel of 250 to 400 KVA DG sets and replacing with new AMF logic controller including replacement of existing unserviceable wiring with 1.5 sqmm PVC multistranded copper conductor single core 1100 V cable for voltmeter, indicator lamp, frequency meter etc complete all as specified and as directed.

1

-

-

... More
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre installed at VISHWA VIHAR, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.

5

-

-

... More
Comprehensive maintenance and servicing of gate barriers of span 7.2 metre installed at ASTE, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.

5

-

-

... More
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre installed at SDI, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.

5

-

-

... More
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre installed at IAM, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.

5

-

-

... More
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre installed at 26 ED, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.

5

-

-

... More
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre installed at 26 ED VIP GATE, electrically operated, lifting type, of make : M/S NIKASH including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed by Engr-in-Charge.

5

-

-

... More
Comprehensive maintenance and servicing of Sliding gate electrically operated including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc., installed at SDI (AF) complete for smooth functioning all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply and fix Electronic Controller for suitable gate barrier complete all as specified and as directed.

2

-

-

... More
Supply and fix wheels suitable for sliding gate installed at SDI complete all as specified and as directed.

6

-

-

... More
Supply and fix starter bendix suitable for 400 / 320 KVA DG installed at IAM complete all as specified and as directed.

1

-

-

... More
Supply and replace New radiator suitable 125 to 400 KVA DG Sets CUMINS Make installed at ASTE/ SDI/ IAM complete all as specified and as directed.

1

-

-

... More
Repair and servicing of 275 KVA fuel injection pump and injectors by replacing the unserviceable parts like centre shaft, loading spring, D valve-6nos,bearings, governorsbarrels & plungers, O ring kits, gasketkits, injectorplunger & barrel, injector elements-6 Nos, ball check and reassembling, testing etc complete all as specified and as directed.

1

-

-

... More
Repair and servicing of 320 KVA fuel injection pump instaled at SDI and injectors by replacing the unserviceable parts like centre shaft, loading spring, D valve-6nos, bearings, governorsbarrels & plungers, O ring kits, gasketkits, injectorplunger & barrel, injector elements-6 Nos, ball check and reassembling, testing etc complete all as specified and as directed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.