Military Engineer Services Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Nov 2024
Closing Date14 Dec 2024
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning filling in excavated soil and refilling of trenches with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and as directed by Engr-in-Charge.

2.43

-

-

... More
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.

31.41

-

-

... More
Supply and fix in repair energy saving rectangular LED flood light fitting 150 Watts, 240 volts AC, cool white colour, CCT 5700°K, CRI70, THD10%, system lumens not less than 100lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and as directed.

11

-

-

... More
Supply and fix in repair energy saving rectangular LED flood light fitting 200 Watts, 240 volts AC, cool white colour, CCT 5700°K, CRI70, THD10%, system lumens not less than 100lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and as directed.

10

-

-

... More
Preventive maint of UPS cum voltage regulator 20 KVA 415 Volt 50 Hz by the authorised service Engineer of UPS the equipment will be checked / inspected any time for detecting and certified the fault during the 06 month complete all as specified. Note: Rates are deemed to be included in the item rates for the following service and servicing will be carried out quarterly during the contract period:- (a) Ensure equipment is clean where approriate. (b) Visual inspection of the UPS. (c) Check all re-set, where necessary relevant present adjustment. (d) To rectify any apparent fault, where immediately possible, records other for later rectificatuion. (e) To taking of electrical measurement to established the operation state of the UPS.

2

-

-

... More
(f) Check setting of adjustable device. (g) Visual inspection of UPS batteries. (h) Checking for correct and accurate operation of all instruments. (j) Record total voltage of battery under float condition. (k) Check each battery voltage once during the contract period. (l) Cost of all spare parts included in the item rate quoted except. wound component AC/DC capacitor, Fan and batteries. (m) Checking and installation of Software and hardware program if necessory with proper othorised dealer of UPS company, rate of software and hardware included in above job rate

-

-

-

... More
Preventive maint of UPS cum voltage regulator 10 KVA 415 Volt 50 Hz by the authorised service Engineer of the equipment will be checked / inspected any time for detecting and certified the fault during the 06 month complete all as specified. Note: Rates are deemed to be included in the item rates for the following service, service will be carried out quarterly during the contract period:- (a) Ensure equipment is clean where approriate. (b)Visual inspection of the UPS. (c) Check all re-set, where necessary relevant present adjustment. (d) To rectify any apparent fault, where immediately possible, records other for later rectificatuion. (e) To taking of electrical measurement to established the operation state of the UPS.

2

-

-

... More
(f) Check setting of adjustable device. (g) Visual inspection of UPS batteries. (h) Checking for correct and accurate operation of all instruments. (j) Record total voltage of battery under float condition. (k) Check each battery voltage once during the contract period. (l) Cost of all spare parts included in the item rate quoted except. wound component AC/DC capacitor, Fan and batteries. (m) Checking and installation of Software and hardware program if necessory with proper othorised dealer of UPS company, rate of software and hardware included in above job rate

-

-

-

... More
Supply and fixing in replacement of Communication interface board(CIB board) of 10 KVA UPS and replacing the board with complete connection of existing cables with and CIB board makeing ups running condition complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of Communication interface board(CIB board) of 20 KVA UPS and replacing the board with complete connection of existing cables with and CIB board making ups running condition complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of Monitoring unit Board and programing flashing of 20 KVA ups, with complete connection through authorised operator/aplicator of manufacturer as per site, complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of Monitoring unit Board and programing flashing of 10 KVA ups, proper coy make existing at site with complete connection through authorised operator/aplicator of manufacturer as per site, complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement charger board of 20 KVA UPS of manufacturer as per site, all as specified and directed.

1

-

-

... More
Supply and fixing in replacement charger board of 10 KVA UPS existing in site complete all as specified and directed. Make : Liebert or existing in site/approved by Engr in Charge

1

-

-

... More
Supply and fix in replacement old unserviceable SMF type 12 volt 42 AH battery conecting each other, with suitable size of copper plate/bracket as recommended by manufacturer and including taking down old unserviceable battery complete all as specified and directed.

40

-

-

... More
Supply, Install testing and commissioning in replacement of Automatic transfer switch of capacity three phase 415 Volt, 50Hz, 4 pole and 160 Amp having suitable to 02 incoming and one out going with inbuilt time delay all as per cat part No. 1HYFSAO160 of make - Havells (or equivalent in make - L&T/ Orient). The ATS should be capable of transfering load of first feeder to second feeder on failure of first feeder and vise versa automatically, the switch should have provision for automatic operation as well as manual operation and should be able for wall mounted including sheet metal enclouser with extrended terminal if required easy fixing of incoming and outgoing connection with free maint of work and taking down existing complete all as specified.

2

-

-

... More
Supply, Install testing and commissioning in replacement of Automatic transfer switch of capacity three phase 415 Volt, 50Hz, 4 pole and 100 Amp having suitable to 02 incoming and one out going with inbuilt time delay all as per cat part No. 1HYFSAO160 of make - Havells (or equivalent in make - L&T/ Orient). The ATS should be capable of transfering load of first feeder to second feeder on failure of first feeder and vise versa automatically, the switch should have provision for automatic operation as well as manual operation and should be able for wall mounted including sheet metal enclouser with extrended terminal if required easy fixing of incoming and outgoing connection with free maint of work and taking down existing complete all as specified.

2

-

-

... More
Supply, Install testing and commissioning in repalcement of Automatic transfer switch of capacity three phase 415 Volt, 50Hz, 4 pole and 63 Amp having suitable to 02 incoming and one out going with inbuilt time delay all as per cat part No. 1HYFSAO160 of make - Havells (or equivalent in L&T/Orient). The ATS should be capable of transfering load of first feeder to second feeder on failure of first feeder and vise versa automatically, the switch should have provision for automatic operation as well as manual operation and should be able for wall mounted including sheet metal enclouser with extrended terminal if required easy fixing of incoming and outgoing connection with free maint of work and taking down existing complete all as specified.

2

-

-

... More
Supply and fixing in replacement of heavy duty Capacitor of capacity 25 KVAR cylindrical type of following capacity fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of heavy duty Capacitor of capacity 15 KVAR cylindrical type, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of heavy duty Capacitor of capacity 10 KVAR cylindrical type, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of heavy duty Capacitor of capacity 5 KVAR cylindrical type, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of heavy duty Capacitor of capacity 2 KVAR cylindrical type, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of heavy duty Capacitor of capacity 1 KVAR cylindrical type, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of 25 KVAR Capacitor MOC25, heavy duty contactor, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of 15 KVAR Capacitor MOC15, heavy duty contactor, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of 10 KVAR Capacitor MOC10, heavy duty contactor, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of 5 KVAR Capacitor MOC10, heavy duty contactor, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of 2 KVAR Capacitor MOC2/3, heavy duty contactor, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of 1 KVAR Capacitor MOC2/3, heavy duty contactor, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of MCB TP 'C' Curve, 10 KA Breaking Capacity, 63 Amp, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of MCB TP 'C' Curve, 10 KA Breaking Capacity, 32 Amp, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of MCB TP 'C' Curve, 10 KA Breaking Capacity, 20 Amp, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of MCB TP 'C' Curve, 10 KA Breaking Capacity, 16 Amp, fixed in existing APFC Panel complete all as specified and directed.

10

-

-

... More
Taking down the unserviceable changeover switch after disconnecting from LT panel board , supply and fix new on load type changeover SS enclosure 415V 200A 4Pole , 50Hz including necessary fabrication , addition and alterations all as specified and directed.

4

-

-

... More
Taking down the unserviceable changeover switch after disconnecting from LT panel board , supply and fix new on load type changeover SS enclosure 415V 400A 4Pole , 50Hz including necessary fabrication, addition and alterations all as specified and directed.

3

-

-

... More
S&F in repair On load change over switch 125 Amp 4 Pole 415 volts, 50 Hz suitable for existing panel board all as specified and directed.

5

-

-

... More
S&F in repair On load change over switch 63 Amp 4 Pole 415 volts ,50 Hz suitable for existing panel board all as specified and directed.

5

-

-

... More
S&F in repair On load change over switch 160 Amp 4 Pole 415 volts ,50 Hz suitable for existing panel board all as specified and directed.

3

-

-

... More
Supply and fixing in repair of Battery Charger 24V , 20A all as specified and directed Make : Naren or equivalent

3

-

-

... More
Supply and fixing in repair of Battery Charger 12V , 10A Model - SMPS in make NHP or equivalent in other makes.

4

-

-

... More
Servicing and cleaning of exhaust vent hoods with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required (Twice during the contract period) all as specified & directed.

200

-

-

... More
Servicing and cleaning of exhaust SS hoods with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required, Burning of ducting and blower, balancing of impeller, painting, replacements of nuts and bolts, rivets etc. (Twice during the contract period) all as specified & directed.

200

-

-

... More
Servicing and cleaning Grease filters with necessary chemical consumables all as directed

24

-

-

... More
Servicing and repairs including windings of Exhaust Blower of 5 HP all as directed

4

-

-

... More
Remove unserviceable 3HP motor and take to workshop after removing the unserviceable winding with new suitable copper including changing bearings overhauling and testing, refixing as directed

4

-

-

... More
Remove unserviceable 5HP motor and take to workshop after removing the unserviceable winding with new suitable copper including changing bearings overhauling and testing, refixing as directed

2

-

-

... More
Supply and fixing in repairs 0.8mm thick, GI Ducting as per required size as per site condition as directed.

500

-

-

... More
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre, electrically operated, lifting type, of including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed. Note: The period of interval for cleaning shall be per months.

24

-

-

... More
Comprehensive maintenance and servicing of Hangar gate electrically operated including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc., complete for smooth functioning all as specified and as directed. Note: Electronic Controller shall be measured and paid separately

10

-

-

... More
Supply and Fix Electronic Controller for suitable Gate Barrier any make all as directed

4

-

-

... More
Repair / maintenanace / servicing and checking of defects of storage type solar water heater of capacity 100/200/500/1000 ltrs at different locations by disconnecting inlet / outlet connections , painting of solar water stand and water tank stand with black paint weatheir proof , repair of foundations , repalcement of electric cables as per site requirement testing all as specified and directed.

18

-

-

... More
S&F in replacement of Hot water tank of capacity 100 LPD for solar water heater made out of premium grade stainless steel , inner coating with high grade anit corrosive coating , outer cladding .45mm galvanised ron with PP powder coating all as specified and directed.

5

-

-

... More
S&F in replacement flate plate collector box suitable for solar water heater of capacity 200 LPD , made of specially extruded aluminium channel for durability and good aesthetic look • The top cover is made of toughened glass with high transmissivity • Absorber fins are made of high quality aluminium and coated with high absorptivity low emissivity solar selective coating • The risers and headers are made of thick gauged high quality copper tubes • The absorber fins are ultrasonically bonded to the riser tubes for high thermal efficiency and longer life inclduing connection with hot /cold water pipes complete all as specified and directed.

14

-

-

... More
S&F in replacement flate plate collector box suitable for solar water heater of capacity 100 LPD , made of specially extruded aluminium channel for durability and good aesthetic look • The top cover is made of toughened glass with high transmissivity • Absorber fins are made of high quality aluminium and coated with high absorptivity low emissivity solar selective coating • The risers and headers are made of thick gauged high quality copper tubes • The absorber fins are ultrasonically bonded to the riser tubes for high thermal efficiency and longer life inclduing connection with hot /cold water pipes complete all as specified and directed.

16

-

-

... More
S&F in replacement of solar heating element 3 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.

15

-

-

... More
Supply and fixing in replacement collector toghened glass of flat collector box suitable for solar water heater of capacity 200/100 LPD complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement of hose pipe for flate plate collector of solar water heater of capacity 100/200 LPD complete all as specified and directed.

22

-

-

... More
M&L for disconnecting and taking down hot water tank of solar water heater of capacity 100/200LPD for descalling and refixing at the same location complete all as specified and directed.

16

-

-

... More
M&L for disconnecting and taking down flate plate collector of solar water heater of capacity 100/200LPD for descalling and refixing at the same location complete all as specified and directed.

18

-

-

... More
M&L for disconnecting and fixing in replacement of flange nipple for solar flate collector complete all as specified and directed

12

-

-

... More
Supply and fixing in replacement collector gasket (EPDM) complete all as specified and directed

12

-

-

... More
Supply and fixing in replacement of temperature gauge for hot water tank of solar water heater of any type and capacity complete all as specified and directed.

8

-

-

... More
Supply and fixing in replacement make up tank for solar water heater of capacity 200 Ltr including taking down of exiting defecting tank complete all as specified and directed.

8

-

-

... More
M&L for collector gas welding for damaged collector due to freezing and testing after welding complete all as specified and directd.

6

-

-

... More
M&L for maintenance and servicing of 2 Ton HOT crane of make Hi Tek Engineers & tecno services including cleaning of all parts and carry out corrective maintenance for trouble free working, attend complaints on call complete all as specified and as directed. SCOPE OF WORK (a) Cleaning and greasing of girder, wheels, drive chain and gear. (b) Full testing including load bearing test once during the contract period. (c) All mechanical parts of the crane to be checked, cleaned and lubricated to keep the crane in perfect working condition. (d) Cost of minor spares like nuts, bolts and washers deemed to be included. (e) Removal of foreign object on the rail.

3

-

-

... More
M&L for maintenance and servicing of 5 Ton HOT crane of make Century Fab-Tech Pvt Ltd including cleaning of all parts and carry out corrective maintenance for trouble free working, attend complaints on call complete all as specified and as directed. SCOPE OF WORK (a) Cleaning and greasing of girder, wheels, drive chain and gear. (b) Full testing including load bearing test once during the contract period. (c) All mechanical parts of the crane to be checked, cleaned and lubricated to keep the crane in perfect working condition. (d) Cost of minor spares like nuts, bolts and washers deemed to be included. (e) Removal of foreign object on the rail.

3

-

-

... More
Comprehensive maintenance of Passenger Lift (Capacity 650Kgs) in SRE Complex to carry out periodical Maintenance once 30 days which Includes checking of Cables, gear, speed Governor, Gear Oil etc, complete all as specified and directd. SCOPE OF WORK (a) Any part of the lift to be replaced whenever and where ever Necessary on normal wear and tear of the parts on free of cost. (b) Gear Oil, Gears, Bearings of Motor to be replaced whenever necessary and lubication as the said parts to be carried out by the contractor at his own cost. (c) All electrical and mechanical parts of the lift to be checked, cleaned and lubricated to keep the lift in perfect working condition.

3

-

-

... More
(d) Any part or in whole the lift may not be repaired if it is damaged, broken due to accident, due to misuse, willfully or negligence. (e) The following Works/Repairs which are not in scope of work :- (i) Refinishing/Painting (ii) Non-proprietary items of the lift equipments like Car enclosures, Car flooring, Hoistway enclosure, Hoistway and Car door, Door and gate handles, Door bearings, Door frames, sills push box covers in landings, Car buzzer, Emergency light, Alarm device and Batteries. (iii) Any Works/ Services/Repairs which are not in the scope of work will be carried out for which extra cost has to be paid in addition to the contract charges. Note : Old unserviceable/Retrived Material are to be handed over to the department.

-

-

-

... More
Repair of unserviceable passenger Lift (Capacity 650Kgs) at SRE complex with the OEM firm including replacing the following spares.(lift Make: Johnson). Note: (i) Lift fitness certificate to be obtained from OEM before payment. (ii) Spares will be measured and paid seperately as supply only.

1

-

-

... More
Supply only LOGIC BOARD FOR (C) ARD 22PIN

1

-

-

... More
Supply only FMS GLASS

1

-

-

... More
Supply only DOOR BEARING (CENTRE)

3

-

-

... More
Supply only ANTI LIFT BEARING

3

-

-

... More
Supply only DOOR SLIPPER(POD)

3

-

-

... More
Supply only GATE LOCK ELEMENT (POD) FEMALE

2

-

-

... More
Supply only GATE LOCK ELEMENT STUD (F) (POD)

2

-

-

... More
Supply only DE LOCKING LEVER-C.O.

2

-

-

... More
Supply only EMERGENCY LAMP BOARD-LED

1

-

-

... More
M & L in replacement for Earthing complete with copper earth plate electrode of size 600x600x3 mm thick buried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to copper strip 25mmx3mm as earth lead upto a length of 7.5 metre long by means of bolts, nuts, washers etc. and protected by GI pipe light grade 15mm dia/ 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed.

14

-

-

... More
Supply and laying copper strip of size of 25mmx3mm connect to various points etc. all as specified and directed

80

-

-

... More
Supply and laying cable protection GI Pipe size of 40mm light grade all as specified and directed

19

-

-

... More
Supply and fixing in replacement, “Lithium based Energy Efficient Integrated Solar Street Light of 30Watt” in rust proof Aluminium housing with Monocrystalline Solar PV Panel of 75W(-0/+4W)Mono , Lithium Battery 12.8V, 42AH(BIS Certified), IP 65, High brightness W-LED(150 Lm/watt) lamp with Aluminum reflector for better light distribution, Color Temperature 6500K +500K, Microcontroller based charge controller cum driver, automatic dimming function( with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 5 degree C to (+) 45degree C, Charging time 1 day and Autonomy 2 days with dimming Protections: Short Circuit, overload, Reverse polarity and battery protections.

13

-

-

... More
Supply and fxing in replacement of 7 meter high hot dipped octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including fiundation bolts & bracket of isze M20x600mm EN 8 grade 'J" type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2" (inch) wide with etc including dismantling existing pole complete all as specified and directed.

13

-

-

... More
M&L for replacing the unserviceable batteries of solar street light with maintenance free sealed battery of size 120 AH 12V including taking out old unservicealbe batteries all as specified and directed.

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.