Military Engineer Services Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Jul 2024
Closing Date12 Sep 2024
Tender Amount₹ 47,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Sl Item No. 3 above but of capacity above 500 KVA to 750 KVA

15

-

-

... More
All as per Sl Item No. 3 above but of capacity above 750 KVA to 2000 KVA

12

-

-

... More
Material and labour for opening and dismantling of all electrical connection from buck / boost transformer of 11 / 11 KV capacity 4 MVA for servicing purpose for checking of complete bushing assy including removing leakage of oil / replacement of top gasket and assembling the same after servicing and complete testing of buck / boost transformer by the authorized company representative and test certificate shall be furnished complete all as specified and as directed by the Engineer-in-Charge (a) Insulation resistance test (b) Oil temperature alarm trip (c) Winding temperature alarm trip (d) Bucholtz relay alarm trip (e) Low oil level alarm trip (MOG) (f) Vector group (g) Di-electric test of transformer oil (h) Short circuit test (j) Magnetic core balance test (MBT)

4

-

-

... More
Material and labour for opening of all electrical connection from 11 KV automatic voltage regulator and drain out complete oil from the tanks for servicing purpose including opening of top cover and lift the core with help of crane carefully for servicing purpose including servicing of three Nos synchronizing motor for its better functioning including testing of carbon roller assembly/ cleaning of control contact assembly and replacement of the same if required and replacement of minor worn out parts and replacing of top gas kit complete and reassembling the same including making all connection and testing complete for entire satisfaction of Engineer-in-Charge. NOTE :- (a) Quoted rate by the contractor shall be deemed to include for repairing of AVR at site only. 2. Major parts replaced shall be paid separately under relevant items of schedule. 3. Test certificate shall be provide by the contractor after serving job done.

2

-

-

... More
Supply and fix in replacement of step synchronise motor with gear box assembly and shaft sprocket 1 ph 230 v 50 Hz 10 / 15 RPM suitable for 11 KV AVR complete all as specified and as directed.

2

-

-

... More
Supply and fix in replacement of electronic Auto control PCB suitable for 11 KV Automatic voltage regulator including removing the unserviceable one and making all connection as per existing complete all as specified and as directed.

2

-

-

... More
Supply and fix in replacement of flip flop relay suitable for 11 KV automatic voltage regulator complete all as specified and as directed.

2

-

-

... More
Supply and fix in replacement of carbon roller assembly of 11 KV automatic voltage regulator including making all connection and testing complete all as specified and as directed.

20

-

-

... More
Supply and fix in replacement tag and tail with sleeving of 11 KV automatic voltage regulator including making all connection and testing complete all as specified and as directed.

20

-

-

... More
Supply and fix in replacement of pneumatic type on delay timer working on 230V 50 HZ of 11 KV automatic voltage regulator including making all connection and testing complete all as specified and as directed.

2

-

-

... More
Material and labour for taking out bottom trolley of HT OCB / VCB11 KV 400 / 800 Amps capacity after disconnecting power supply and carrying out servicing and maintenance of operating mechanism, latch assembly spring mechanism, checking of electrical control wiring of OCB/VCB and checking for proper functioning of shunt trip coil, lubricating of all moving parts and checking / cleaning of alignment of moving contacts with fixed contact assembly for proper functioning of operation. Reassembling of bottom trolley of HT OCB fixed in its original position and testing for smooth functioning complete all as specified and as directed by Engineer-in-Charge

30

-

-

... More
Material and labour for calibration of IDMT relays set of three through relay test kit including other required measuring equipment to the site by secondary injection method and testing for proper functioning/tripping systems of relays complete all as specified and as directed. NOTE : The rate quoted by the contractor is deemed to be included for quarterly checking of relays in VCB / OBC for its proper setting / functioning and tripping of VCB / OCB during over load / earth fault.

20

-

-

... More
Supply and fixing of HT current transformer of capacity 200 / 100 / 5-5 including testing commissioning of through primary injection method with suitable testing kit and also checking the control panel wiring including setting the CT range with relays setting for proper functioning / tripping and taking out old unserviceable CT complete all as specified and as directed.

3

-

-

... More
Supply and fixing in replacement of moving contact assembly suitable for HT OCB / VCB 11 KV 400 Amps to 800Amp OCB including dismantling the old unserviceable moving contact assembly suitable for HT OCB complete all as specified and as directed.

8

-

-

... More
Supply and fixing in replacement of big and small end bearing of HT 11 KV VCB trolley including replacement of complete locking mechanism with integral spring charging handle for manual spring charge and replacement of closing coil and tripping coil 24V DC including replacement of electro magnetic relay, coil rating 220 V, AC all as specified and as directed.

2

-

-

... More
Supply and fix vaccum Interpture bottle for the existing HT VCB including taking out old unserviceable vaccume Interputure bottol complete all as specified and as directed.

2

-

-

... More
Supply and fix spring charging motor for 11 KV VCB suitable for the existing make including taking out old unserviceable one complete all as specified and as directed.

4

-

-

... More
Supply and fixing in replacement of current transformer moulded in epoxy compound with dual ration 50 / 25 / 5 Amps complete connection with copper wire including beading as per existing VCB 11 KV at site complete all as specified and as directed.

2

-

-

... More
Dismantling and removing of defective transformer removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning / washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair / replacement of coils, gasket, sheet, nuts and bolts, refilling of transformer oil, installation and testing on full load for testing for 11 KV capacity from 630 KVA to 1250KVA complete all as specified and as directed by the Engineer-in-Charge. NOTE : Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer.

2

-

-

... More
Dismantling carefully, material and labour for rewinding the LT / HT side (primary winding / secondary windings) of the transformer with copper winding (wire / strip ) of suitable gauge or to match the existing including refixing, connecting, testing and commissioning the transformer complete all as specified and as directed.

240

-

-

... More
Supply and fix in repairs HT bushing rod complete with insulator and packing suitable for outdoor / indoor type 630 KVA to 1250 KVA transformers confirming to IS-334 complete with nut, bolts, brass studs and gasket of synthetic rubber bonded cork sheet complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
Supply and fix in repairs LT bushing complete with insulator and packing suitable for 1100 volt grade complete with nut, bolts, brass studs, insulator and gasket etc suitable for 630 to 1250 KVA out door / indoor transformer complete all as specified and as directed. NOTE FOR ITEM NOs 24 & 25 :- (i) Rates quoted by the contractor shall be deemed to include for opening of top plate of transformer / decanning of oil from transformer up to the level as per requirement and assemble the same after replacement of bushing rod. (ii) Bushing rod shall be replaced at site. transformer will not be allowed to send to workshop at any cost and all bushing replacement work shall be executed at site only.

6

-

-

... More
Supply and fix air breather complete with silica gel suitable for outdoor type step down power transformer up to 500 KVA to 1250 KVA complete all as specified and as directed.

15

-

-

... More
Material and labour for spray painting of distribution transformer with two coats of synthetic enamel paint of smoke grey colour after neatly cleaning and preparing the surface for spray painting the transformer of the following capacity including writing SM / MES No (5 cm height) with white enamel paint of capacity 1200 KVA to 2000 KVA complete all as specified and as directed.

7

-

-

... More
All as per Sl Item No. 27 above but of capacity 750 KVA to 1000 KVA

7

-

-

... More
All as per Sl Item No. 27 above but of capacity 500 KVA to 630 KVA

16

-

-

... More
All as per Sl Item No. 27 above but of capacity 4000 KVA.

2

-

-

... More
Material and labour for cutting of black top cover of existing road up to 1 mtr depth and 1mtr wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 up to 30 cm from top of the road surface complete all as specified and as directed by Engineer-in-Charge.

20

-

-

... More
Material and labour for opening of electrical connection from existing ACB upto 2500 Amps, draw out / fixed type from the existing panel for servicing purpose of all mechanical part / cleaning / lubricating of all parts including fixing the same in the panel and testing for entire satisfaction of Engineer-in- Charge.

6

-

-

... More
Supply and fixing of tripping coil of air circuit breaker upto 2500 Amps as per existing make and model 220 / 440 volts complete all as specified and as directed.

4

-

-

... More
Supply and fixing of moving contact circuit breaker upto 2500 Amp as per existing make and model complete all as specified and as directed.

3

-

-

... More
Supply and fixing of fixed contact circuit breaker upto 2500 Amp as per existing make and model complete all as specified and as directed.

2

-

-

... More
Material and labour for finding out the cable fault of any size of cable upto 11 KV underground cable HT and LT and of any capacity of cable with the help of cable fault locator mounting on vehicle and with necessary disconnection of cable from two ends and making connection by joining after repairs and having the following items with electrician at site to find fault of upto length of 2 KM cable complete all as specified and as directed by Engineer-in- Charge with help of the following accessories :- (a) Surge Generator with accessories (b) Head Phone (c) Pin Point Set T-505 with accessories (d) Earthing cable with clamp (e) Cable fault Locator T-905 with accessories (f) TC-808 with accessories (g) Soldering Iron / wire / capacitor unit / capacitor connecting cables / power cable / nose plier. NOTE : Excavation for the cable fault shall be done by the contractor by his own arrangement.

6

-

-

... More
Material and labour for opening of all connection of electric power cable of any size from the electrical panel, cleaning and replacing of aluminium lugs of existing cable of size upto 400 sq.mm upto 20 Nos in each panel and checking of all electrical wiring of panel and servicing of bus bar strip changing etc and tightening of nuts and bolts and making all connection as per original including testing for entire satisfaction of Engineer-in- Charge.

10

-

-

... More
Supply and fixing HT digital display voltmeter suitable for HT OCBs, HT VCBs at various substation suitable for HT panel 1100 / 100 volts (auxiliary volts) including necessary connections and taking out old unserviceable complete all as specified and as directed.

6

-

-

... More
Supply and fixing HT digital type ammeter suitable for CT ratio 50 / 100 / 200 Amps including necessary connections and taking out unserviceable ammeter complete all as specified and as directed.

6

-

-

... More
Supply and fix in replacement MD XL type 10 KVAR to 20 KVAR capacitor 440 volt, 3 Phase, voltage test between terminals 1.75 rated volt including taking out unserviceable complete all as specified and as directed.

2

-

-

... More
All as per Sl Item No. 40 above but 25 KVAR

2

-

-

... More
Supply and fix steel MCCB enclosure on wall suitable for fixing of MCCB of 3 pole / 4 pole capacity upto 250 Amp complete all as specified and as directed.

2

-

-

... More
Supply and fix steel MCCB enclosure suitable for fixing of MCCB of 3 pole / 4 pole capacity upto 315 Amp to 630 Amp complete all as specified and as directed.

2

-

-

... More
Material and labour for repair of LT panel board by replacement of broken / unserviceable front door of LT panel made out of 3.15mm thick MS sheet to shape for proper closing the front door in two parts including making locking arrangement of LT panel and welding of new hinges, spray painting of panel board complete all as specified and as directed.

10

-

-

... More
Trimming of tree / branches including cutting of grass at substation and surrounding upto 5 Mtr radius and removing the grass and branches and transporting the same outside the labs complete all as specified and as directed.

20

-

-

... More
Supply and fixing distilled water best quality suitable for lead acid battery complete all as specified and as directed.

80

-

-

... More
Maintenance and servicing of battery panel 220 / 110 / 30 / 24V DC with batteries and its control panels wiring, PCB, Relays and terminal cables with replacement of defective parts complete all as specified and as directed.

3

-

-

... More
Supply and install, testing and commissioning maintenance free (SMF) lead acid battery, 2 Volts, comprising of maintenance free batteries of reputed make with all accessories including taking down old unserviceable battery from battery bank complete all as specified and as directed.

30

-

-

... More
Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged complete all as specified and as directed.

6

-

-

... More
Material and labour for servicing of 415 Volt electrical panel indoor / outdoor type for cleaning of dust particle inside the panel like MCCB, relay / contactor with help of blower etc and tightening of all electrical connection and complete testing and replacement of burnt lugs etc complete all as specified and as directed.

20

-

-

... More
Supply and fix cable route indicator comprises and made out of PCC pole (0.3 x 0.3 x 1.5 Mtr) on HT cable 1 mtr in depth grouted in the ground with suitable PCC 1:3:6 concrete base with writing HT CABLE / JOINT complete all as specified and as directed.

60

-

-

... More
Supply and fix flanged gate valve size 100 mm dia for the existing transformer including taking out old unserviceable valves complete all as specified and as directed.

2

-

-

... More
Supply and fix flanged gate valve size 50 mm dia for the existing transformer including taking out old unserviceable valves complete all as specified and as directed.

2

-

-

... More
Supply and fix flanged gate valve size 25mm dia for the existing transformer including taking out old unserviceable valves complete all as specified and as directed.

2

-

-

... More
Supply and refilling of SF6 (Sulfur hexafluoride gas) for 11 KV RMU SF6 outdoor circuit breaker to cool and Quench the arc on opening of circuit transmission class for normal operation to maintain the desired pressure in SF6 and RMU as per OEM design and testing the pressure of each SF6 breaker 11 KV RMU complete all as specified and as directed.

8

-

-

... More
Material and labour for maintenance, servicing and repair of 4 way RMU panel SF6 Breaker / Load Break switch HT 11KV 400 Amps / 800 Amps 50 cycles, internal moving and fixed parts, contacts / wiring, cleaning, dusting, decarbonising, tightening loosened parts, checking of closing / tripping system, lubricating greasing all moving parts, including replacing worn out part copper studs, bolts, nuts and washers replacing control wiring, replacing oil, busbar contacts fixed or moving contacts, HT bush, gasket including unserviceable coil, replacing of defective minor items such as indicators lamp, push button, selector switch etc as and when required complete all as specified and as directed. NOTE : The item spare parts shall be replaced measured and paid separately, However minor items such as indicator, push button, selector switch, gasket, wiring cable shall be deemed to be included in the unit rate.

1

-

-

... More
All as per Sl Item No. 56 above but 6 way RMU

1

-

-

... More
All as per Sl Item No. 56 above but 9 way RMU

1

-

-

... More
Supply and installing 100mm width x 50mm depth x 1.6mm thickness size of perforated hot dipped Galvanised Iron cable tray (Galvanisation thickness not leass than 50 microns) with perforation not more than 17.5% inconvenient sections, jointed with connectors, suspended from the ceiling with GI suspenders including GI Bolts and nuts as required all as specified by Engineer-in -Charge NOTE : (i) All necessary fixing / connecting arrangements of nut, bolt, MS rod, to be provided by the contractor without any extra payment from department. (ii) Quoted rate is to be deemed the charges of necessary boom lift.

50

-

-

... More
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in hard / dense soil complete all as specified and as directed.

200

-

-

... More
Removing excavated material to a distance not exceeding 50m and deposting where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.

63

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed by Engineer-in- Charge.

137

-

-

... More
Material and labour for sand cushioning to underground cable providing with a layer 8cm thick before laying the cable and 15 cm thick after laying the cable complete all as specified and as directed. NOTE : Punned thickness only will be measured for the purpose of payment.

56

-

-

... More
Material and labour for unreinforced precast concrete covers class HV type 300mm x 180mm x 40mm size factory made for cable protection complete all as specified and as directed.

1000

-

-

... More
Material and labour for unreinforced precast concrete covers class LV type 250mm x 150mm x 40mm size factory made for cable protection complete all as specified and as directed.

3500

-

-

... More
Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 sq.mm 3.5 core including taking up existing old unserviceable LT UG cable complete all as specified and as directed.

80

-

-

... More
All as per Sl Item No. 66 above but of size 300 sq.mm 3.5 core

80

-

-

... More
All as per Sl Item No. 66 above but of size 240 sq.mm 3.5 core

80

-

-

... More
All as per Sl Item No. 66 above but of size 185 sq.mm 3.5 core

100

-

-

... More
All as per Sl Item No. 66 above but of size 120 sq.mm 3.5 core

100

-

-

... More
All as per Sl Item No. 66 above but of size 95 sq.mm 3.5 core

100

-

-

... More
All as per Sl Item No. 66 above but of size 70 sq.mm 3.5 core

120

-

-

... More
All as per Sl Item No. 66 above but of size 50 sq.mm 3.5 core

100

-

-

... More
Supply, laying and testing in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor,11000 volts grade, of size 3 core 95 sq.mm including taking out of old HT cable from trenches complete all as specified and as directed by Engineer-in- Charge.

80

-

-

... More
All as per Sl Item No. 74 above 120 sq.mm 3 core

100

-

-

... More
All as per Sl Item No. 66 above 185 sq.mm 3 core

100

-

-

... More
Supply and fix cable jointing kit 11 KV cable for indoor termination heat shrink type joint complete joint material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sq.mm to 95 sq.mm complete aluminiuml as specified and as directed.

8

-

-

... More
Supply and fix cable jointing kit 11 KV cable for outdoor termination heat shrink type joint complete joint material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sq.mm to 95 sq.mm complete aluminiuml as specified and as directed.

6

-

-

... More
Supply and fix cable jointing kit 11 KV cable for indoor termination heat shrink type joint complete joint material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq.mm to 185 sq.mm complete aluminiuml as specified and as directed.

8

-

-

... More
Supply and fixed cable jointing kit 11 KV cable for outdoor termination heat shrink type joint complete joint material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq.mm to 185 sq.mm complete aluminiuml as specified and as directed.

4

-

-

... More
Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 sq.mm to 185 sq.mm, Indoor / Outdoor type complete aluminiuml as specified and as directed.

4

-

-

... More
Supply and fixing in repairs LT Air circuit breaker Manual Draw-out type circuit breaker thermal magnetic DN1 four pole 1250 Amps capacity of 50 KA breaking capacity in existing panel board including modification if required to accommodate the ACB with necessary connection with existing bus bar with suitable lugs, nuts, bolts, washers etc including testing commissioning complete and taking out existing unserviceable ACB of any capacity complete all as specified and as directed.

1

-

-

... More
Supply and fixing in repairs LT Air circuit breaker fixed type circuit breaker thermal magnetic DN1 four pole 1250 Amps capacity of 50 KA breaking capacity in existing panel board including modification if required to accommodate the ACB with necessary connection with existing bus bar with suitable lugs, nuts, bolts, washers etc including testing commissioning complete and taking out existing unserviceable ACB of any capacity complete all as specified and as directed.

1

-

-

... More
Supply and fix in repairs Moulded Case Circuit Breakers for Distribution Network with thermal magnetic release type DPX 250 3 pole 100 Amps capacity 16 KA rupturing capacity in existing panel board including modification on existing panel if required, necessary connectioning with copper strips / suitable size of copper conductor wire from bus bar, provision of suitable size of copper lugs as per the outgoing cable including taking down unserviceable MCCB complete all as specified and as directed. Make : L&T / ABB / Schneider / Legrand

5

-

-

... More
All as per Sl Item No. 84 above but 3 pole 160 Amp 36 KA

2

-

-

... More
All as per Sl Item No. 84 above but 4 pole 200 Amp 36 KA

2

-

-

... More
All as per Sl Item No. 84 above but 4 pole 250 Amp 36 KA

2

-

-

... More
All as per Sl Item No. 84 above but 3 pole / 4pole 400 Amp 36 KA

4

-

-

... More
All as per Sl Item No. 84 above but 3 pole/ 4 pole 630 Amp 50 KA

2

-

-

... More
Supply and laying Synthetic Insulating Mat of size 2.00 Mtr x 1.00 Mtr x 2.5mm thick suitable for upto 33 KV grade complete all as specified and as directed.

10

-

-

... More
Supplying, spreading and leveling graded course stone aggregate of 40mm to 80mm size to the existing sub station complete all as specified and as directed. NOTE : Aggregate nominal size without any vegetation or chemical including levelling / spreading surrounding transformer, HT / LT 2 / 4 pole structure and LT / HT panel complete all as directed .

6

-

-

... More
Material and labour for copper earth continuity main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit of size 20mm x 3mm complete all as specified and as directed.

50

-

-

... More
Material and labour for earthing complete with copper earth plate of size 600mm x 600mm x 3.15mm buried directly in ground (earth pit not less than 3 mtr deep below ground level) with top edge of the plate not less than 2.1m below normal ground level, connected to and including copper earth strip of 20mm x 3mm by means of riveting and brazing and protected by GI pipe light grade of suitable size up to the test point , ie upto 7.5m, including providing alternate layers upto full volume of pit by charcoal dust and common salt, magnesium sulphate and vegetable soil all around the plate 15cm depth and width minimum including PCC pit chamber, watering pipe of 50mm dia medium grade HI pipe upto the top of the plate having funnel complete and RCC cover, connecting to the test point and testing on ground complete and including excavation and earth work in any type of strata and cleaning of site all as specified and as directed in MES SSR Part-I and directed NOTE : (i) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (ii) Copper strip above 7.5m will be measured and paid separately. (iii) Earth resistance not exceeding 1.0 ohm.

4

-

-

... More
Earthing complete with galvanized iron plate electrode 600 x 600 x 6.00mm thick GI earthing lead burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with the top edge of the plate at a depth not less than 1.5 mtr from below normal GL, connected to and including Galvanised iron strip 32mm x 6mm as earthing lead by means of nuts, bolts, washers, checknuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part l of 2010 and as specified or indicated and testing on completion including excavation / earth work in any type of strat PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (Reinforced with welded steel wire fabric (XPM)) weight not less than 4 Kg/sqm,cast iron frame, funnel with wire mesh, including GI earth strip with GI protection pipe of 40mm medium grade 7.5 meter long etc complete and testing on completion all as specified and directed. NOTE :- (i) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate (ii) GI strip above 7.5m will be measured and paid separately.(iii) Earth resistance not exceeding 1.0 ohm.

6

-

-

... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32mm x 6mm galvanized iron or steel wire complete all as specified and as directed.

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.