Military Engineer Services Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date25 Oct 2024
Closing Date18 Nov 2024
Tender Amount₹ 39,99,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & filling sand cushioning to under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable complete all as specified considering as per SSR 1991 of part -I Note: Only punned thickness of the sand will be meausured.

154

-

-

... More
Supplying and laying unreinforced precast concrete cable cover, class LV Type-1, flat size 250mm x 150mm x 40mm with ISI mark factory made complete all as specified and directed.

12660

-

-

... More
Taking down carefully old unserviceable UG cable of any size from the trenches/wall/pole and keeping aside for reuse and remove the unservicable cable from site after affording credit depending on its serviceability state including removal of brick/PCC cable cover complete all as specified and directed.

2500

-

-

... More
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 25 sqmm 4 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work

500

-

-

... More
All as per Item No.07 here-in-before but for 35 sqmm 3.5 core complete all as specified and directed

500

-

-

... More
All as per Item No.07 here-in-before but for 50 Sqmm 3.50 core complete all as specified and directed.

250

-

-

... More
All as per Item No.07 here-in-before but for 70 sqmm 3.50 core complete all as specified and directed

250

-

-

... More
All as per Item No.07 here-in-before but for 95 sqmm 3.50 core complete all as specified and directed

250

-

-

... More
All as per Item No.07 here-in-before but for 120 sqmm 3.50 core complete all as specified and directed

250

-

-

... More
All as per Item No.07 here-in-before but for 185 sqmm 3.50 core complete all as specified and directed

250

-

-

... More
All as per Item No.07 here-in-before but for 240 sqmm 3.50 core complete all as specified and directed

250

-

-

... More
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 35 sq.mm. Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule

2

-

-

... More
All as per Item No.15 herein before but for cable of size 3.5 core 50 sq.mm complete all as specified and directed.

2

-

-

... More
All as per Item No. 15 herein before but for cable of size 3.5 core 70 sq.mm complete all as specified and directed.

2

-

-

... More
All as per Item No.15 here-in-before but for 3.50 core cable 95 Sq mm complete all as specified and directed.

2

-

-

... More
All as per Item No.15 here-in-before but for 3.50 core cable 120 to 150 Sq mm complete all as specified and directed.

1

-

-

... More
All as per Item No.15 herein before but for cable of size 3.5 core 185 sq.mm complete all as specified and directed.

1

-

-

... More
All as per Item No. 15 herein before but for cable of size 3.5 core 240 sq.mm complete all as specified and directed.

1

-

-

... More
All as per Item No.15 here-in-before but for 3.50 core cable 300 Sq mm complete all as specified and directed.

1

-

-

... More
M/L for MCCB 3 pole, 415 volts ,25 to100 Amps with breaking capacity 16 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.

1

-

-

... More
All as per Item No.23 herein above but for 125 Amps with breaking capacity 16 KA complete all as specified and directed.

2

-

-

... More
All as per Item No.23 herein above but for 160 Amps with breaking capacity 25 KA complete all as specified and directed.

1

-

-

... More
All as per Item No.23 herein above but for 200 Amps with breaking capacity 25 KA complete all as specified and directed.

2

-

-

... More
All as per Item No.23 herein above but for 250 Amps with breaking capacity 36 KA complete all as specified and directed.

2

-

-

... More
All as per Item No.23 herein above but for 350 Amps with breaking capacity 36 KA complete all as specified and directed.

1

-

-

... More
All as per Item No.23 herein above but for 400 Amps with breaking capacity 36 KA complete all as specified and directed.

1

-

-

... More
All as per Item No.23 herein above but for 630 Amps with breaking capacity 50 KA complete all as specified and directed.

1

-

-

... More
M/L for MCCB 4 pole, 415 volts ,100 Amps with breaking capacity 16 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.

1

-

-

... More
All as per Item No.31 herein above but for 125 Amps with breaking capacity 16 KA complete all as specified and directed.

1

-

-

... More
All as per Item No.31 herein above but for 160 Amps with breaking capacity 25 KA complete all as specified and directed.

1

-

-

... More
All as per Item No.31 herein above but for 200 Amps with breaking capacity 25 KA complete all as specified and directed.

1

-

-

... More
All as per Item No.31 herein above but for 250 Amps with breaking capacity 36 KA

1

-

-

... More
All as per Item No.31 herein above but for 350 Amps with breaking capacity 36 KA complete all as specified and directed.

1

-

-

... More
All as per Item No.31 herein above but for 400 Amps with breaking capacity 36 KA complete all as specified and directed.

1

-

-

... More
All as per Item No.31 herein above but for 630 Amps with breaking capacity 50 KA complete all as specified and directed.

1

-

-

... More
M&L for servicing to indoor/outdoor LT panel board, opening up all cubical doors, cleaning with air blower, removing the burnt out unserviceable instruments, copper wiring kit, and burnt out unserviceable extended copper terminals/ copper cable and replacing with new copper extended terminal bus bar with suitable size along with required nut bolt, washers, and replacing the measuring instruments like Ammeter with existing size of the CT, Volt meter, indicating lamps of LED type 'R Y B' cleaning with CTC to serviceable parts like MCCB's, all terminals, replacement of damaged aluminum lugs any description of LT U/G cables in coming and out going, replacement of deterioated copper wiring with suitable copper conductor with circuit indicator replacement of sheared rubber beadings to door of panels, including preparing the existing surface for spray painting to powder coated surface with two coat of synthetic enameled paint of approved colour, marking of incoming and out going feeder with fluorecent stickers incl preparation of the surface of panel complete all as specified and directed.

6

-

-

... More
NOTE :- [i] The rates are deemed included for cleaning with CTC oil and terminating of LT U/G cable any description and wiring kits with suitable copper conductor along with connector, painting,and marking with Incoming & Outgoings details of the panels with fluorescent strickers and necessary bolt, nut and washers etc. [ii] The spares are like Aluminum lugs, sheared rubber gasket of panel doors, indicator lamp, volt meter, Amps meter with required sizes of CT, and selector switch, copper conductor cable other than wiring kit shall be measured and paid separatly under relevant items of this schedule as supply only.

-

-

-

... More
Supply only the following items :- Volt meter digital type 0-500 Volts

4

-

-

... More
Ammeter digital type suitable to 0 - 100 Amps

5

-

-

... More
Aluminum lugs suitable for 25 sqmm to 50 sqmm cables

10

-

-

... More
Aluminum lugs suitable for 70 sqmm to 150 sqmm cables

12

-

-

... More
Aluminum lugs suitable for 150 to 300 sqmm cables

16

-

-

... More
Sheared rubber gasket suitable to LT panel board any description

8

-

-

... More
Indicator lamp LED type 'RYB'

10

-

-

... More
M&L for GI tubing 'Light' grade 50 mm bore with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area for following sizes of pipes :-

8

-

-

... More
All as per Item No.47 herein above but for 80 mm bore complete all as specified and directed.

8

-

-

... More
All as per Item No.47 herein above but for 100 mm bore complete all as specified and directed.

8

-

-

... More
M&L for Preparation of old painted steel surfaces and applying two coats of synthetic enamel paint of approved shade on exposed surfaces of LT panel boards including writing / marking feeders all as specified and as directed.

100

-

-

... More
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth plate with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.

6

-

-

... More
Supplying and fixing 32mm X 6mm ,GI earth strip all as specified and directed. Note:- Above quoted rate incl all the cutting/drilling jobs required for joining the earth strip with existing earth strip/test point incl nuts and bolts for the lap joints.

10

-

-

... More
Laying only in repair LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 25 sqmm 4 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule [ii] If old LT UG cable will found serviceable to be relaying the same.

20

-

-

... More
All as per Item No.53 here-in-before but for 35 sqmm 3.5 core complete all as specified and directed.

20

-

-

... More
All as per Item No.53 here-in-before but for 50 Sqmm 3.50 core complete all as specified and directed.

20

-

-

... More
All as per Item No.53 here-in-before but for 70 sqmm 3.50 core complete all as specified and directed.

40

-

-

... More
All as per Item No.53 here-in-before but for 95 sqmm 3.50 core complete all as specified and directed.

40

-

-

... More
All as per Item No.53 here-in-before but for 120 sqmm 3.50 core complete all as specified and directed.

60

-

-

... More
All as per Item No.53 here-in-before but for 185 sqmm 3.50 core complete all as specified and directed.

60

-

-

... More
All as per Item No.53 here-in-before but for 240 sqmm 3.50 core complete all as specified and directed.

60

-

-

... More
S&F DWC high density polyethylene pipes having 63/50 mm dia with all fittings/coupler/connecting accessories cnfirming to IS : 16098 Part-02 and IS: 16025 Part -24 for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and directed.

72

-

-

... More
S&F DWC high density polyethylene pipes having 90/76 mm dia with all fittings/coupler/connecting accessories cnfirming to IS : 16098 Part-02 and IS: 16025 Part -24 for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and directed.

72

-

-

... More
Servicing of Automatic Power Factor Correction (APFC) panel of the Capacity 300 KVAR complete comprising any type capacitors, APFC relay, MCCB, Cooling Fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contatct points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge.

2

-

-

... More
All as per item No. 63 here-in-before but capacity 180 KVAR complete all as specified and directed.

2

-

-

... More
Servicing, Inspecting, checking, cleaning by using of blower,Lubrication ,greasing and carrying out preventive maintanance of ACB and ACB in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge.

6

-

-

... More
Excavation of existing cable of size 25 Sq mm to 150 Sq mm removing from its loop of length 3m to 5m, cleaning, cutting of old termination and reconnecting the same along with termination at ends with suitable new aluminium lugs and refilling of cable trench with existing sand and bricks complete all as directed. Note: The rate quoted shall include for necessary earth work

6

-

-

... More
Excavation of existing cable of size 185 Sq mm to 300 Sq mm removing from its loop of length 3m to 5m, cleaning, cutting of old termination and reconnecting the same along with termination at ends with suitable new aluminium lugs and refilling of cable trench with existing sand and bricks complete all as directed. Note: The rate quoted shall include for necessary earth work

6

-

-

... More
Disconnecting, dismantling of existing LT Busbar Junction Box and supply, fabricate, install with new cable gland and lugs on existing cable, testing and commissioning of Busbar Junction Box of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 600 amps for three phase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 25 KA breaking cap adjustable thermal release range 250 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessoris all as directed by the Engr In Charge.

1

-

-

... More
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.