Military Engineer Services Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Jan 2025
Closing Date18 Feb 2025
Tender Amount₹ 60,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil, complete all as specified and directed.

249.31

-

-

... More
Removing excavated soil to a distance not exceeding 50m and deposited at a level not exceeding 1.5m above the starting point, complete all as specified and directed.

179.88

-

-

... More
Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 80 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.

24

-

-

... More
Material and labour for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) for foundations, filling in mass concrete, all as specified and as directed.

1

-

-

... More
Material and labour for plain cement concrete 1:3:6 type C1 using (20 mm graded stone aggrega) for path ways, hard standing & pole coping including necessary form work and applying two coats of white wash on exposed surfaces etc complete all as specified and as directed.

2.5

-

-

... More
Material and labour for GI tubing light grade, 50mm dia with all necessary fittings, laid in trenches, under floor/road crossing, fixed on poles for cable protection fixed with the clamps made out of FI 25 x 3mm duly painted with two coats of aluminium paint over a coat of approved primer etc. including taking down old unserviceable any size and capacity of GI pipe complete all as specified and directed.

30

-

-

... More
Material and labour for GI tubing light grade, 80mm dia with all necessary fittings, laid in trenches, under floor/road crossing, fixed on poles for cable protection fixed with the clamps made out of FI 25 x 3mm duly painted with two coats of aluminium paint over a coat of approved primer etc. including taking down old unserviceable any size and capacity of GI pipe complete all as specified and directed.

20

-

-

... More
Supply and fix brass hydrant valve 63 mm double headed type including taking down of old unserviceable one, complete all as specified and directed.

12

-

-

... More
Supply and fix fire hose of 15 m length 63 mm dia with brass hose clamp including taking down of old unserviceable one, complete all as specified and directed.

16

-

-

... More
M & L as in repair for hose box of any description and providing new hose box made of MS sheet with double door with 4mm thick glass and door frame made of MS sheet painted fire red outside and brilliant white inside yard complete all as directed.

2

-

-

... More
Supply and fix Hose reel Drum 30 m of dia 25 mm dia including taking down of old unserviceable one complete all as specified and directed.

4

-

-

... More
Supply and fix as in repair of 2mm thick transoarent Arcilary sheet for Hose reel Drum and hose box complete all as specified and directed.

5

-

-

... More
M& L for preparation to external old steel surface of pipe of various size and completely removal of existing paint by scraping or chemical and applying one coat of synthetic enamel paint, complete all as specified and as directed. Note :- (i) Colour of paint shall be decided by Engr-in-Charge. (ii) Scafolding and other safety precautions is included in quoted rate.

25

-

-

... More
Supply and installation, programming and testing of fire control panel complying with Morley DXc4 4 loop fire alarm per loop 198 addressable points 99 dectors plus 99 device per loop 6*40 charactor blue crystal display with backlight illumination 2 sounder circuit PT requires network card MOF795099 additionnally for network including taking down of old one, complete all as specified and as directed. Make : Honeywell/Ceasefire/Visionic/Universal (Ravel)

1

-

-

... More
Supply and fix in repair of MS pipe ERW Heavy (IS1239) errect, jointing complete of 150 mm dia with necessary supports and specials such as tees, bends, reducers etc including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc, complete all as specified and as directed.

24

-

-

... More
Supply and fixing in replacement butterfly valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.

2

-

-

... More
Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 150 mm ISI marked, CI body suitable for 150 mm pipe line complete all specified and directed.

2

-

-

... More
Supply and fix in repair of MS pipe ERW Heavy (IS1239) errect, jointing complete of 100 mm dia with necessary supports and specials such as tees, bends, reducers etc including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc complete all as directed..

30

-

-

... More
Supply and fixing in replacement butterfly valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.

4

-

-

... More
Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 80 mm ISI marked, CI body suitable for 80 mm pipe line complete all specified and directed.

2

-

-

... More
M& L for preparation to external old steel surface of hose box/door/panel board of various size and completely removal of existing paint by scraping or by using chemical and surface painted with synthetic enamel paint with help of brush complete all as specified and as directed. Note :- (i) Colour of paint shall be decided by Engr-in-Charge.

45

-

-

... More
Supply and fix in repair of MS pipe ERW Heavy (IS1239) errect, jointing complete of 80 mm dia with necessary supports and specials such as tees, bends, reducers etc including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc complete all as directed..

12

-

-

... More
Supply and fixing in replacement butterfly valve of size 80 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.

2

-

-

... More
M&L for taking down defective centrifugal pump set 75 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at same location as directed. by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed.. Note :- (a) The spares shall be measured and paid seperately in the relevent items. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by Enginner in Charge egarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000/- per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

2

-

-

... More
Supply only Ball bearing suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.. Make : Tata/SKF/NBC

1

-

-

... More
Supply only coupling Rubber Bush suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed..

2

-

-

... More
Supply only split casing gaskets suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed..

1

-

-

... More
Supply only shaft sleeves suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed..

1

-

-

... More
Supply only coupling bolt with nuts suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed..

2

-

-

... More
Supply only water seal suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed..

1

-

-

... More
Supply only Air cock grease nipple suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed..

1

-

-

... More
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed..

1

-

-

... More
Supply only complete cashing suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed..

1

-

-

... More
Supply only bronze impeller suitable for 75 HP capacity motor pump as per manufacturer's design complete all as specified and as directed..

1

-

-

... More
M&L for rewinding of squirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed. and specified for the 75 HP motor capacity.

1

-

-

... More
M & L for servicing fire pump panel which has maximum six pump operated by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to fire pump panel by welding,cutting , grinding ,drilling and rewiring with proper coloured coading and testing the panel auto manual mode, complete all as specified and directed. Notes :- (i) Minor spare parts such as nuts, bolts, washers ,indicator lamps, start,stop push button and suitable size of copper wire are deemed to be include in quoted rate. (ii) Copper conductor paid measured separately.

2

-

-

... More
Supply & install in replacement Addressable manual call point resettable type, complete all as specified and directed. Make :- Ceasefire/ Visionic/ Universal (Ravel)/ Honeywell or equivalent as per site requirement.

8

-

-

... More
Supply & install in replacement Addressable electronic sounder cum strobe, complete all as specified and directed.. Make :- Ceasefire/ Visionic/ Universal (Ravel)/ Honeywell or equivalent as per site requirement.

6

-

-

... More
Supply & install in replacement Addressable monitor module, complete all as specified and directed. Make :- Ceasefire/ Visionic/ Universal (Ravel)/ Honeywell or equivalent as per site requirement.

5

-

-

... More
Supply & install in replacement smoke and heat detectors, photoelectric / optical type certified to EN 54 addressable with self built intelligent with connected accessories complying with optical chamber, cover, case moulding, photodiode (transducer), infrared LED all as specified and directed.. NOTE:- (i). Metal junction box of suitable size for detector made of 16 SWG sheet steel is to be provided for mounting of detectors in the concrete mother ceiling / surface along with necessary gland and boxes duly painted with two coats of super enamelled paint over a coat of red oxide primer. (ii) Rate of metal boxes shall be included in quoted rate of items. Make :- Ceasefire/ Visionic/ Universal (Rqvel)/ Honeywell or equivalent as per site requirement.

8

-

-

... More
Supply & install in replacement Addressable control module, complete all as specified and directed. Make :- Ceasefire/ Visionic/ Universal (Ravel)/ Honeywell or equivalent as per site requirement.

5

-

-

... More
Supply and installation ,programming and testing of fire PLC control panel complying with BS EN 54 1 loop panel with 99 detector & 99 module DXc1 Single loop Fire Alarm Control Panel two loop card inbuild198 addressable points 99 detectors Plus 99 devices per Loop 6*40 character blue crystal display with backlight 11 devices per Loop 6*40 character blue crystal display with backligh illumination 2 Sounder circuits PT requires network card MOF795099 additionally for netwok including taking down of old one, complete all as specified and as directed. Make : Honeywell/Ceasefire/Visionic/Universal (Ravel)

1

-

-

... More
Supply & install in replacement Fire Alarm Sounders / Sirens Electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtrs range, complete all as specified and directed. Make :- Ceasefire/ Visionic/ Universal (Ravel)/ Honeywell or equivalent as per site requirement.

2

-

-

... More
Supply & install 2 core solid conductor of size 1.5 sqmm, as per IS-1554 PVC insulated & PVC sheathed, armoured cable FRLS drawn through non metallic PVC conduit of suitable size shall be properly clamped to the ceiling / surfaces including taking down of unserviceable cable and 'S' loop shall also be left where cables connect to sounders, panels and all the cables and wires shall be tagged for proper identification complete all as specified and directed..

320

-

-

... More
Taking down defective Jockey pump set 7.5 HP to 15 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed. by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.

2

-

-

... More
Supply only coupling Rubber Bush suitable for 7.5 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed..

1

-

-

... More
Supply only coupling bolt with nuts suitable for 7.5 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed..

1

-

-

... More
Supply only Ball bearing suitable for 7.5 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.. Make : Tata/SKF/NBC

2

-

-

... More
Supply only Air cock grease nipple suitable for 7.5 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed..

2

-

-

... More
Supply only shaft sleeves suitable for 7.5 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed..

2

-

-

... More
Supply only split casing gaskets suitable for 7.5 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed..

2

-

-

... More
Supply only water seal suitable for 7.5 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed..

2

-

-

... More
Supply only bronze impeller suitable for 7.5 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed..

2

-

-

... More
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 7.5 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed..

2

-

-

... More
Supplying and fixing of 1100 volts grade heavy duty cable of size 16 Sqmm PVC insulated 6 core Armoured copper conductor, served with inner sheathing of PVC tape and overall PVC sheathed incl taking out old unsv complete all as specified and directed

80

-

-

... More
M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed. and specified for the 7.5 HP to 15 HP motor capacity, complete all as specified and directed.

2

-

-

... More
Material and labour in repair for 3.5 core 50 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.

450

-

-

... More
Material and labour in repair for 3.5 core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.

250

-

-

... More
Material and labour in repair for 3.5 core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.

550

-

-

... More
Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.

450

-

-

... More
Material and labour in repair for 4 core10 Sqmm XLPE insulated heavy duty electric cable with aluminium single stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.

1025

-

-

... More
Supply and fix 4 Pole MCCB ,415 volts,fixed type ,400 Amp, 50 Hz, with rupturing capacity 36 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed.

2

-

-

... More
Supply and fix 4 Pole MCCB ,415 volts,fixed type ,250 Amp, 50 Hz, with rupturing capacity 36 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed.

2

-

-

... More
Supply and fix 4 Pole MCCB ,415 volts,fixed type ,160 Amp, 50 Hz, with rupturing capacity 36 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed.

4

-

-

... More
Supply and fix 4 Pole MCCB ,415 volts,fixed type ,100 Amp, 50 Hz, with rupturing capacity 25 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed.

4

-

-

... More
Supply and fix 4 Pole MCCB ,415 volts,fixed type ,63Amp, 50 Hz, with rupturing capacity 16 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed.

5

-

-

... More
Supplying and fixing of 1100 volts grade heavy duty cable of size 10 Sqmm PVC insulated twin core aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed incl taking out old unsv complete all as specified and directed

180

-

-

... More
Supplying and fixing of 1100 volts grade heavy duty cable of size 6 Sqmm PVC insulated twin core aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed incl taking out old unsv complete all as specified and directed

360

-

-

... More
Supply and fix LED Bollard light IP 65 rated LED with soft 360 degree light distribution 10 watt LED lamp complete With all accessories and including suitable PCC foundation etc, complete all as specified and as directed.

5

-

-

... More
Material & Labour for wiring to suitable for strret light fitting connection taping from the line / connecting up from the junction box to the fitting etc with two run of 1.5 Sqmm multistranded PVC insulated copper conductor with PVC conduit not less than 20mm and necessary clamp including taking down old unserviceable wiring, complete all as specified and as directed. NOTE - Two run of 1.5 Sqmm cable including PVC conduit shall be measured as one unit.

220

-

-

... More
Supply, jointing, testing straight through jointing kit heat shrinkable out door type, suitable for LT 1100 Volts grade cable of size 10 Sqmm to 16 Sqmm 4 core complete all as specified and directed..

5

-

-

... More
Supply, jointing, testing straight through jointing kit heat shrinkable out door type, suitable for LT 1100 Volts grade cable of size 25 Sqmm to 50 Sqmm 3.5 core complete all as specified and directed

4

-

-

... More
Supply and fixing LED street light fitting of 36 watts/sizes 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed

50

-

-

... More
Supply and fixing LED street light fitting of 45 watts/sizes 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed

25

-

-

... More
Supply and fixing LED street light fitting of 70 watts/sizes 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed

22

-

-

... More
Supply and fixing LED street light fitting of 90 watts, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed

8

-

-

... More
Supply and fixing LED flood light 50 watts 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed

8

-

-

... More
Supply and fixing LED flood light 70 watts 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed Make : Bajaj/CG/Phillips

16

-

-

... More
Supply and fixing LED flood light 100 watts 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed

12

-

-

... More
Supply and fixing LED flood light 120 watts 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed

10

-

-

... More
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed

16

-

-

... More
Supply and fixing post top lantern LED type 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed

15

-

-

... More
Supply and fix in GI pipe 50mm dia, medium grade for mounting bracket bent to shape 1.5 meter length and fixing arrangement with two Nos of clamps set, nut, bolts, washers, including taking down of old unserviceable pipe, complete complete all as specified and directed.

20

-

-

... More
Supply and fix in GI pipe 40mm dia, medium grade for mounting bracket bent to shape 1.5 meter length and fixing arrangement with two Nos of clamps set, nut, bolts, washers, including taking down of old unserviceable pipe, complete complete all as specified and directed.

10

-

-

... More
S & F aluminum lugs suitable for aluminum cable of size 10 to 35 Sqmm complete all as specified and directed

45

-

-

... More
S & F aluminum lugs suitable for aluminum cable of size 50 to 95 Sqmm complete all as specified and directed

50

-

-

... More
S & F aluminum lugs suitable for aluminum cable of size 120 to 185 Sqmm complete all as specified and directed

50

-

-

... More
S & F copper lugs suitable for copper cable of size 10 to 35 Sqmm complete all as specified and directed

50

-

-

... More
Supply and fix street light terminal boxes factory made out of 1.6mm thick PVC sheet with hinges and locking arrangement of size 300x200x100mm housing in and including 25x4mm bus bar of suitable length fixed on porcelian insulator with proper size of screw terminal connector with one No of MCB SP 6 Amps, 240volts, in/out cable gland of suitable size fixed on street light pole with nut, bolt and washers etc, complete all as specified and directed.

40

-

-

... More
Supply & fixing of Polycarbonate Cable Junction box of size 205 mm x 255 mm x 112 mm “weather proof”, for outdoor installation (with knockouts for cable entry) pole mounted front operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2 dead back, free standing, dust and vermin proof, switchboard with IP 66 protection with suitable for use 440 volts, 3 phase 4 wire 50 Hz system complete all as per Cat No - KF 2525 of make - Hensal or equivalent in other makes.

20

-

-

... More
Supplying & fixing Polycarbonate Cable Junction box Cable Junction box of size 155 mm x 210 mm x 92 mm “weather proof”, for outdoor installation (with knockouts for cable entry) pole mounted front operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2 dead back, free standing, dust and vermin proof, switchboard with IP 66 protection with suitable for use 440 volts, 3 phase 4 wire 50 Hz system complete all as as per Cat No - KF 1616 of make - Hensal or equivalent in other makes.

25

-

-

... More
Servicing/ comprehensive maintenance of fire alarm system comprising of Smoke detection control panel, Smoke detector (Photoelectric detection Technology), Conventional Fire Alarm control panel, flame detector, conventional manual call point with EN 54-11 : 2001 and LPCB, conventional sounder etc by attending fault testing of system, quarterly checking of system including preventive maintenance by replacing small spare parts complete all as specified and directed.

3

-

-

... More
Note:- (a) The repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The rate quoted shall be deemed to include for carry out all repairs noticed during the period. (c) The authorised service agency must attend as and when called for urgent nature of repair of the fire alarm equipment's. (d) Checking of Alarm signal should not lost when primary power failure untill the alarm signal processed. (e) Checking of smoke detector sensibility (f) Checking of all speaker circuit and loops. (g) Periodicity shall be overall 3 months or as per manufacturers recommendations.

-

-

-

... More
Attending unserviceable/ non functional street light complaints (for street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillers etc) by deploying technically qualified and experienced technicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed at AFS Jalahalli, AFTC and 2 DC area. Note : The following items are deemed to be inclusive of quoted rate :- (i) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.

710

-

-

... More
(ii) Contractor or his Authorised Representative has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very regular basis. (Every succeding day) (iii) A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User along with Contractor or his authorised Representative. (iv) Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account.

-

-

-

... More
(v) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipment's to remove the breakdown. Fault will be intimated through Telephone/ SMS. (vi) Contractor shall provide conveyance to the employed labour for maintaining the services without any extra cost to department. (vii) Vehicle mounted ladder for maitenance services shall be provided by the contractor at no extra cost to department. (viii) Materials required for the repairing of the lights shall be measured and paid separately under respective item(s) . But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to be included in the rate quoted. (ix) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.

-

-

-

... More
(x) All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department. (xi) Attending and repairing complaint for one light of any type shall be measured and paid as one Job. (xii) Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items. (xiii) Contractor has to ensure serviceability of all Street/ Security Lights in above mentioned DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement. (xiv) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.

-

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity upto 36 Watt LED fittings complete all as specified & directed.

45

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity 40 to 45 watt LED fittings complete all as specified & directed.

65

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity 50 to 75 watt LED fittings, complete all as specified & directed.

70

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity 80 to 100 watt LED fittings complete all as specified & directed.

25

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity 120 to 150 watt LED fittings complete all as specified & directed.

18

-

-

... More
Supply and fixing the surge protection device 5KV voltage compatible with industrial and out door type LED fixtures including taking down of old one complete all as specified & directed.

20

-

-

... More
M&L for wiring of unserviciable Timer panel box and replacement of existing size of copper wire and copper lugs and testing complete all as specified and as directed

1

-

-

... More
Supply and fix in repair contactors of capacity 32- 40 A 3 Pole 415 V with 2NO+2NC including taking down of old one complete all as specified and as directed .

2

-

-

... More
Supply and fix as in repair NO/NC of capacity 40A of 415 V including taking down of old one, complete all as specified and as directed .

2

-

-

... More
Supply and fix MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: , including taking down of old one complete all as specified and as directed .

2

-

-

... More
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal whether proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel.

1

-

-

... More
The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.

-

-

-

... More
The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed including the following subcomponentSupply and fixing eatures :-

-

-

-

... More
(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible. Make- Tricolite/ Kewintech/HPL

-

-

-

... More
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel.

1

-

-

... More
The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.

-

-

-

... More
The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :-

-

-

-

... More
(a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) GSM based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 06 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible. Make- Tricolite/ Kewintech/HPL

-

-

-

... More
Material and labour for painting to steel tubular pole with aluminium enamel paint of 7.5/9 Mtr including cross arms, clamps any size and nuts, bolts etc with one coat of aluminium synthetic enamel paint including preparing the surfaces free from finish particalsand making the smooth surface and numbering on pole with black ground such as pole number and source of supply, painting with black & yellow paint around the pole at width of 10cm, similar three rounds from 1.5 m GL top on circumferance of pole complete all as specified and directed.

550

-

-

... More
Material and labour for cement base paint of applying one coat of cement RCC pole 7.5/9 metre long, byafter scraping / brushing and cleaning the rust on street light bracket to painted with on coat of Aluminium paint. Cement colour will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and yellow enameled paint (30 Cms Each) Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete, all as specified and directed.

450

-

-

... More
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.

52

-

-

... More
Copper strip 20 x 3.15mm thick as earthing lead fixed to wall/roofs etc including taking down existing one, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.

132

-

-

... More
Supply and fix in repair smart integrated solar all in one LED solar street light fitting 12 V,15 Watts with IP 66 protection, built-in MPPT charge controller,Lithium ion battery,mono crystalline solar panel, PIR motion sensor complete with anodised reflector, toughened heat resistant glass cover, LED 15 watts white colour lamp, connector block with all accessories pre wired including bracket,welding,drilling,bolts,nuts and any alteration required for fixing the panel with existing pole, complete all as specified and as directed.

5

-

-

... More
Supplying, errecting and fixing as in repair GI tubular swaged welded pole of over all height 6.0 m long for all in one solar light complete with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed . Note - (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole of copping shall be painted with 2 coats of block and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular shall be painted with 2 coats of aluminium paint over a coat of red oxide primer the rate for above items shall be deemed to be inclusive in the quoted rate.

5

-

-

... More
Comprehensive maintenance of Automatic Power Factor Correction Panels (APFC ) at various sub stns of capacities 125 KVAr -1 No,160 KVAr-01 No, 60 KVAr - 01 No , 120 KVAr - 01 No and 30 KVAr - 01 No and comprising of following works :- (i) Repair / maintenance of Contactors, Relays and Capaciters , MCCBs & MCBs provided in the APFC Panel (ii) Monitoring and effective management of power factor correction near to unity as per the veriation of load in the corrrosponding transformer in terms of serviceability of MCCB/MCBs , Contactors , Capacitors and Relay and dispaly unit inculding the following Technical services:- The following daily Maintenace to be carried out : (a) Check seviciablity of APFC panels , MCCBs/MCBs, Contactors, Relays etc. (b) Maintain a register to note the values of power factor from all APFC Panels and VCBs panel at MRS and that should be submitted to Engineer in Charge. (c) Check the connection and serviciablity of incoming cable from Main LT Panels to APFC Panels (d) Checking and tightening control wiring and rectifying the defects if any.

-

-

-

... More
Note : (i) The Contractor will responsible for maintaining the power factor near to unity on induvidual APFC Panels and overhaul the value at main Receiving Station. Contracor will responsible for, the penalty/ compensation charges which charged by BESCOM , due to Low Power factor and same amount should be paid by the contractor from his own account. The above quoted rate is inclusive of all regarding to maintain the APFC Panel power factor. (ii ) The Capacitors, Contactors, Relays replaced will be measured and Paid separetly. However, the labour element is included for replacement of wornout/ defective components.

-

-

-

... More
Supply only three phase power capacitor duty contactors of 5 KVAR ratings including taking down old unserviceable capacitor, complete all as specified and as directed .

2

-

-

... More
Supply only three phase power capacitor duty contactors of 10 KVAR ratings including taking down old unserviceable capacitor, complete all as specified and as directed .

6

-

-

... More
Supply only three phase power capacitor duty contactors of 12.5 KVAR ratings including taking down old unserviceable capacitor, complete all as specified and as directed .

1

-

-

... More
Supply only three phase power capacitor duty contactors of 20 KVAR ratings including taking down old unserviceable capacitor, complete all as specified and as directed .

4

-

-

... More
Supply only three phase power capacitor duty contactors of 25 KVAR ratings including taking down old unserviceable capacitor, complete all as specified and as directed .

2

-

-

... More
Supply only three phase power capacitor duty contactors of 50 KVAR ratings including taking down old unserviceable capacitor, complete all as specified and as directed .

1

-

-

... More
Supply only TP, MCB 20 to 32 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified

15

-

-

... More
Supply only contactor suitable for 5 KVAr Capacitor, all as specified & directed.

2

-

-

... More
Supply only contactor suitable for 10 KVAr Capacitor, all as specified & directed.

2

-

-

... More
Supply only contactor suitable for 12.5 KVAr Capacitor, all as specified & directed.

2

-

-

... More
Supply only contactor suitable for 20 KVAr Capacitor, all as specified & directed.

2

-

-

... More
Supply only contactor suitable for 25 KVAr Capacitor, all as specified & directed.

2

-

-

... More
Supply only contactor suitable for 50 KVAr Capacitor, all as specified & directed.

2

-

-

... More
Supply and fixing in replacement MCB SP 6A, all as specified & directed.

4

-

-

... More
Supply and fixing in replacement MCB SP 16A, all as specified & directed.

3

-

-

... More
Supply and fixing in replacement MCB SP 63A , all as specified & directed.

2

-

-

... More
Supply and fixing in replacement MCB SP 32A , all as specified & directed.

3

-

-

... More
Supply only Electric cooling fan single phase 240 Volts suitable for APFC panel, all as specified & directed.

2

-

-

... More
Supply only APFC relay square flush type with Intelligent Power Factor Controller 12/16 Step, all as specified & directed.

1

-

-

... More
Supply only Indicator lamps (RYB) complete all as specified and directed

24

-

-

... More
Supply and fixing in replacement of wiring of APFC panel with including copper wire ,PVC wire holder and other connected items suitable for APFC panel 30 KVAr to 250 KVAr capacity as per existing make including testing and complete all as specified and directed.

3

-

-

... More
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.

52

-

-

... More
NOTE - The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate. (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.

-

-

-

... More
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate. (iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with sample approval. (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.

-

-

-

... More
(vi) Copper strip of size 20 x 3 mm (99.99% molecularly copper) should be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM will be considered in unit quoted rate and extra will be measured and paid separately). (vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned. (viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab. (ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.

-

-

-

... More
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. (xiii) A security deposit of value equal to 2.5 % of the rate quoted for each chemical earthing each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.

-

-

-

... More
(xiv) The electrode shall carry manufacturer's name . (xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. (xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil. (xviii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material along with sample approval. (xix) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed .

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.