Military Engineer Services Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Feb 2025
Closing Date5 Mar 2025
Tender Amount₹ 49,99,000 
Notes
Download

Costs

Summary

Repair Maint Of Certain Misc E M Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format as directed by Engr-in-charge & shall be deposited to concerned JE E/M within 24 hrs.

-

-

-

... More
(d) All sort of petty T&P items such as PVC insulation tape, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor without any extra cost to deptt.

-

-

-

... More
(j) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.

-

-

-

... More
(k) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor shall be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforced above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.

-

-

-

... More
(l) The decision of the Accepting Officer in this regard shall be final and binding.

-

-

-

... More
Supply only switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian

350

-

-

... More
Supply only switch piano flush type 5 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian

15

-

-

... More
Supply only switch piano flush type 15 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian

75

-

-

... More
Supply only shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed Make : Anchor, Havells, L&T, Indoasian

40

-

-

... More
Supply only shuttered socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed Make : Anchor, Havells, L&T, Indoasian

15

-

-

... More
Supply only switch socket combination out let 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian

40

-

-

... More
Supply only switch socket combination out let 5 in 1, 5 pin 5 and 15 Amps, flush type, complete all as specified and directed.Make : Anchor, Havells, L&T, Indoasian

120

-

-

... More
Supply only Ceiling rose 3 phase/ PVC/ Polycarbonate, isolated body 6 Amps, 250 volts AC (ISI marked), complete all as specified and directed

100

-

-

... More
Supply only electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt , complete all as specified and directed Make : Havells / Anchor/ crabtree/ Indoasian

200

-

-

... More
Supply only single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996, complete all as specified and directed.(Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 / Indoasian/ Havells.

35

-

-

... More
Supply only metal clad switch socket single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Legrand/ Havells/ Indoasian

5

-

-

... More
Supply only modular switch 1 way 6 Amp.1 module , complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian

60

-

-

... More
Supply only modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian

35

-

-

... More
Supply only modular switch 1 way 16 Amp, 1 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian

30

-

-

... More
Supply only modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian

25

-

-

... More
Supply only plug top 3 pin 15 Amps AC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza/ Indoasian

5

-

-

... More
Supply only 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton

120

-

-

... More
Supply only electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/ cona/ Plaza/Indoasian/ Havells

100

-

-

... More
Supply only electronic LED driver 46/47W suitable for 2' x 2' ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed.

20

-

-

... More
Supply only electronic fan regulator modular type 230 volts, step type socket type, hum free 100/240 watt, complete all as specified and directed. Make : Havells / Anchor/ Crabtree/ Indoasian.

40

-

-

... More
M&L for in repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtr complete all as specified and directed. Note : All safety measures is the responsible of the contractor.

20

-

-

... More
M&L in repair for stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/wooden beading fixed on wall including necessary fixing arrangement up to height 11 mtr complete all as specified and directed. Note : All safety measures will be the responsibility of the contractor

40

-

-

... More
S&F LED bed side light /wall light/study light environmentel friendly energy effcient of capacity 3 W warm white etc,inbuilt driver complete with all accessories internally pre-wired swing type and including connecting up to with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed . Make : Philips/ Bajaj / CG/Havells.

15

-

-

... More
Supply and Fixing electric Gong Bell, AC 230 volt, ringing type complete all as specified and directed. Make : Havells / Anchor/ Crabtree/ Indoasian.

3

-

-

... More
Taking down aluminium/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plastered surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed.

202

-

-

... More
M&L in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 Sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through surface PVC conduit/ existing concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 Sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed for following points:- Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).

-

-

-

... More
One light point/fan/bell point controlled by one switch.

60

-

-

... More
All as per item No. 34 here in before but for one 3 pin socket out 5 Amp on the same board

15

-

-

... More
All as per item No. 34 here in before but for one switch socket outlet 3 pin 5 Amps on independent board

20

-

-

... More
All as per Sl No 34 above but Wiring with 4 Sqmm copper multistranded unsheathed FRLS cable and 4 Sqmm copper cable FRLS for earth continuity conductor controlled by one 15A switch socket independently.

20

-

-

... More
M&L in repairs for point wiring complete with 1.5 Sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor drawn through and incl surface PVC Conduit/ existing concealed conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 Sqmm PVC insulated, unsheathed copper conductor multistranded FRLS cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for the following points :- Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Supreme/ Diplast/ Avon Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).

-

-

-

... More
One light point/fan/bell point controlled by one switch.

40

-

-

... More
All as per item No. 39 here in before but for One 3 pin socket out 5 Amp on the same board

12

-

-

... More
All as per item No. 39 here in before but for one switch socket outlet 3 pin 5 Amps on independent board

15

-

-

... More
All as per Sl No 39 above but Wiring with 4 Sqmm copper multistranded unsheathed FRLS cable and 4 Sqmm copper FRLS cable for earth continuity conductor controlled by one 15A switch socket independently

15

-

-

... More
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T

95

-

-

... More
Supply and Fix switch piano flush type 15 Amps 240 volts single pole one way, complete all as specified and directed.Make : Anchor, Havells, L&T, Indoasian

20

-

-

... More
Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian

35

-

-

... More
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian

20

-

-

... More
Supply and Fix modular switch 1 way 6 Amp.1 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/ Indoasian

72

-

-

... More
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/ Indoasian

72

-

-

... More
Supply and Fix modular switch 1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor/ Indoasian

15

-

-

... More
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/ Indoasian

15

-

-

... More
Supply and Fixing in repairs of 4 feet surface mounted battern type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of 100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white Aluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI 80, Color temperature 6500K, THD 10% and PF 0.95,SDCM5, IP20, IK02. Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content5% and shall have high and low cut off with auto restart feature. Make : Philips/ Bajaj / CG/Havells.

950

-

-

... More
Supply & fix in repair decorative recessed mounted ultra slim square profile 1X1 feet 20 W LED lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 20 Watt and including cosidering material & labour for fixing ceiling hight upto 15 Mtr, complete all as per site requirement and as directed.

6

-

-

... More
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth in any type of soil for laying of cables etc up to proper level complete all as specified and directed.

363.38

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.

211.08

-

-

... More
Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above from the starting point complete all as specified and directed.

152.29

-

-

... More
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- (i) Excavated approved soil obtained from excavation under item No 33 shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.

130.82

-

-

... More
Material and labour for well burnt ‘B’ sub class bricks as protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed.

11.3

-

-

... More
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate complete all as specified and directed. Note :- The tenderer shall take into consideration for the following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material/rubbish out side MD land (iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.

50

-

-

... More
Supply only GI pipe light grade for cable protection of size 40mm bore complete with fitting complete all as specified and directed.

50

-

-

... More
Material and labour in repair for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts, fixed to wall/pole etc complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian

400

-

-

... More
Material and labour in repair for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts, fixed to wall/pole etc complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian

300

-

-

... More
Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts, fixed to wall/pole etc complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian

500

-

-

... More
Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes of 80 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed.

40

-

-

... More
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25 - 50 Sqmm 3.5 core size of LT underground armoured cables etc complete all as specified and directed. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.

30

-

-

... More
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF 0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 150 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board complete all as specified and all as directed and comprising of the following:-

1

-

-

... More
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 25 KA - 01 No (Incomer). (b) MCB TPN of 415 V of capacity 63 Amps, 4 Pole, 10 KA - 07 Nos.. (c) MCB SPN of 240 V of capacity 40 Amps, 10 KA - 02 Nos. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (vi) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).

-

-

-

... More
Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with black up to 1.5 meter from top of PCC 1:2:4 using 20 mm graded stone aggregate for coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 using 40 mm graded aggregate foundation and coping as per TD drawing including dismantling damaged pole complete all as specified and as directed.Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate.

6

-

-

... More
Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole/ wall etc complete all as specified and directed.

25

-

-

... More
Supply & fixing of Cable Junction box of size 205 mm x 255 mm x 112 mm “weather proof”, for outdoor installation (with knockouts for cable entry) pole mounted front operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2 dead back, free standing, dust and vermin proof, switchboard with IP 66 protection suitable for use 440 volts, 3 phase 4 wire 50 Hz system. The Board/Panel shall be made out of moduler POLYCARBONATE THERMOPLASTIC ENCLOSURES. The gasket material shall be Polyurethane; while the gasket shall be internally embedded. The manufacturer of board/panel shall submit a copy of test report in accordance with IEC60529. The Panel should be assembled at manufactures factory and Panel box having 6 Amp MCB (Make for MCB - C&S/Havells/indoasian and make for cable junction Box - Hensal Cat No - KF 2525 or equivalent of other make ), 25 Sq.mm Terminal Block (04 Nos) ,6 Sq.mm Disconnected Terminal (01 No), 4 Sq.mm Earth Terminal (01 No), gland for cable fixing both incoming & out going including set of MS clamp in suitable size with nut bolts and fixed to street light PCC /tubular pole including taking down old one complete all as directed.

30

-

-

... More
Supply and fix of LED street light fittings 70 watts pressure die cast aluminium housing with toughened glass and high power LEDs with option of secondary optic with IP-66 ingress protection with 4/5KV surge protection device, Manufacturers logo embossed on the housing for traceability (stickering/ printing not acceptable), system level efficacy of the luminarie is 120lm/W . The color temparature is arround 6500K with a color rendering index of 70. The luminaire of IP:66 protected with impact rasistence IK05 impact resistance, electronic driver compliant to IEC safety standards with power factor greater than 0.9, voltage variation range 120-270V, THD less than 20%, high and LED with individual peanut lens and lens plate for better optics. The product should be tested for IEC60598 safety standards, LM80 report for LED, entire product including taking down the old u/s one complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.

20

-

-

... More
Supply and fix of LED street light fittings 45 watts pressure die cast aluminium housing with toughened glass and high power LEDs with option of secondary optic with IP-66 ingress protection with 4/5KV surge protection device, Manufacturers logo embossed on the housing for traceability (stickering/ printing not acceptable), system level efficacy of the luminarie is 120lm/W . The color temparature is arround 6500K with a color rendering index of 70. The luminaire of IP:66 protected with impact rasistence IK05 impact resistance, electronic driver compliant to IEC safety standards with power factor is greater than 0.9, voltage variation range 120-270V, THD less than 20%, high and LED with individual peanut lens and len plate for better optics. The product should be tested for IEC60598 safety standards, LM80 report for LED, entire product including taking down the old u/s one complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.

15

-

-

... More
Supply and fix in repair Time switches Digital 24 hour, 440 V three phase with contactor TP of rating 32 Amps and MCB TPN of rating 40A fitted in steel enclosure with necessary accessories to fixing RCC/steel tubular pole including bracket, nuts, bolts, washers etc. and making all necessary connections through connectors complete all as specified and as directed .Make : L&T/ Havells/ Indoasian

4

-

-

... More
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF 0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 250 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board complete all as specified and all as directed and comprising of the following:-

1

-

-

... More
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 36 KA - 01 No (Incomer). (b) On Load change over front operated of capacity 160 Amp, 4 Pole, 415 V- 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10KA - 04 Nos. (d) MCB SPN of 240 V of capacity 40 Amps, 10 KA - 03 Nos. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No (d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (vi) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).

-

-

-

... More
S& F for replacement of conventional type post top fitting with LED Post tops lamp fitting 40 W LED made of die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make: Philips/Bajaj/CG

5

-

-

... More
Supply and fixing Round spherical garden lighting, post top lantern having B22 holder suitable for LED bulb 10 watt, 220 volt, 50HZ, IP65 including suitable of GI tubing, length as per site requirement on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 Sqmm PVC insulated stranded copper conductor including PCC work for fixing, of light fitting complete all as specified and directed.Make: Philips/ Havells/Bajaj/CG.

10

-

-

... More
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.

36

-

-

... More
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.

-

-

-

... More
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.

-

-

-

... More
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.

-

-

-

... More
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.

-

-

-

... More
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.

-

-

-

... More
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).

-

-

-

... More
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.

-

-

-

... More
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.

-

-

-

... More
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.

-

-

-

... More
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.

-

-

-

... More
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.

-

-

-

... More
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.

-

-

-

... More
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.

-

-

-

... More
(xiv) The electrode shall carry manufacturer's name .

-

-

-

... More
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.

-

-

-

... More
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.

-

-

-

... More
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.

-

-

-

... More
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.

-

-

-

... More
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by Engr -in- charge.

-

-

-

... More
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO.

36

-

-

... More
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.

50

-

-

... More
Supply and Fixing in repairs of 2 feet surface mounted battern type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of 100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white Aluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI 80, Color temperature 6500K, THD 10% and PF 0.95,SDCM5, IP20, IK02. Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content5% and shall have high and low cut off with auto restart feature. Make : Philips/ Bajaj / CG/Havells.

300

-

-

... More
S&F in repairs 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of 100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI 80, Color temperature5700±300K, THD 10% and PF 0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted.Make : Philips/ Bajaj / CG/Havells.

10

-

-

... More
Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts, fixed to wall/pole complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian

400

-

-

... More
Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium single stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts, fixed to wall/pole complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian

300

-

-

... More
Supply and fixing LED flood light fitting of 120 watts pressure die cast housing with IP66 protection with efficient high output emitter LED for better distribution with all accessories pre wired including necessary electric connection and bracket for fixing the fitting all including taking down unserviceable old fitting ,complete all as specified and directed.Make : Bajaj/Philips/CG/Halonix.

10

-

-

... More
Supply and fixing road lighting/ building security luminaire of watt 36 LED street light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings all as specified and directed, Make : Philips /crompton/Bajaj/Halonix

20

-

-

... More
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF 0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 630 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board complete all as specified and all as directed and comprising of the following:-

1

-

-

... More
(a) ON load change over switch 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No . (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 02 Nos. (c) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No (d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (vi) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).

-

-

-

... More
Note :- An amount of Rs 53,551.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.