Military Engineer Services Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Electrical Works
Eprocure
Opening Date2 Nov 2024
Closing Soon23 Nov 2024
Tender Amount₹ 49,95,000 
Notes
Download

Costs

Summary

Repair Maint Of Security Street Light Various Types Of Earthings Lightening Protection System Fire Alarm System

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
8922REPAIR MAINT OF SECURITY STREET LIGHT VARIOUS TYPES OF EARTHINGS LIGHTENING PROTECTION SYSTEM FIRE ALARM SYSTEM AND OTHER MISC E M WORKS AT AFS JALAHALLI
8922BOQREPAIR MAINT OF SECURITY STREET LIGHT VARIOUS TYPES OF EARTHINGS LIGHTENING PROTECTION SYSTEM FIRE ALARM SYSTEM AND OTHER MISC E M WORKS AT AFS JALAHALLI
8922PSREPAIR MAINT OF SECURITY STREET LIGHT VARIOUS TYPES OF EARTHINGS LIGHTENING PROTECTION SYSTEM FIRE ALARM SYSTEM AND OTHER MISC E M WORKS AT AFS JALAHALLI
8922GENPAGEREPAIR MAINT OF SECURITY STREET LIGHT VARIOUS TYPES OF EARTHINGS LIGHTENING PROTECTION SYSTEM FIRE ALARM SYSTEM AND OTHER MISC E M WORKS AT AFS JALAHALLI
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Contractor or his Authorised Representative has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very regular basis. (Every succeding day)

-

-

-

... More
A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User along with Contractor or his authorised Representative.

-

-

-

... More
Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account.

-

-

-

... More
Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipment's to remove the breakdown. Fault will be intimated through Telephone/ SMS.

-

-

-

... More
Contractor shall provide conveyance to the employed labour for maintaining the services without any extra cost to department.

-

-

-

... More
Vehicle mounted ladder for maitenance services shall be provided by the contractor at no extra cost to department.

-

-

-

... More
Materials required for the repairing of the lights shall be measured and paid separately under respective item(s) . But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to be included in the rate quoted.

-

-

-

... More
Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.

-

-

-

... More
All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the tradesmen deployed for providing the services and department will have no liability for any type of accident. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this account.

-

-

-

... More
All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.

-

-

-

... More
Attending and repairing complaint for one light of any type shall be measured and paid as one Job.

-

-

-

... More
Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.

-

-

-

... More
(i) Contractor has to ensure serviceability of all Street/ Security Lights in above mentioned DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.

-

-

-

... More
In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.

-

-

-

... More
The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Charge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.

-

-

-

... More
The decision of the Accepting Officer in this regards shall be final and binding.

-

-

-

... More
M&L for wiring of unserviciable Timer panel box and replacement of existing size of copper wire with copper lugs and other connected items complete all as specified and as directed

4

-

-

... More
Supply and fix contactor of capacity 32- 40 A 3 Pole 415 V with 2NO+2NC including taking down of old one complete all as specified and as directed .Make:- Legrand /Indo Asian /L& T

2

-

-

... More
Supply and fix MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: , including taking down of old one complete all as specified and as directed .Make:- Legrand /Indo Asian /L& T

3

-

-

... More
Supply and fix as in repair NO/NC of capacity suitable for 32-40 A contactor including taking down of old one complete all as specified and as directed . Make:- Legrand /Indo Asian /L& T

2

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity upto 30 watt LED fittings complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement

85

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity of 45 watt LED fittings complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement

120

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity of 75 watt LED fittings complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement

140

-

-

... More
Supply only PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Finolex or equivalent

230

-

-

... More
Supply and fixing the surge protection device 5KV voltage compatible with industrial and out door type LED fixtures including taking down of old one complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement

50

-

-

... More
Supply and fix digital timer switch 24 hrs including taking down of old one complete all as specified and as directed by .Make:- Legrand /Indo Asian /L& T

3

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity of 100 watt LED fittings complete all as specified Make - CG/Phillips/Bajaj or equivalent as per site requirement

35

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity of 150 watt LED fittings complete all as specified Make - CG/Phillips/Bajaj or equivalent as per site requirement

20

-

-

... More
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity of 200 watt LED fittings complete all as specified Make - CG/Phillips/Bajaj or equivalent as per site requirement

10

-

-

... More
Taking down and errecting steel swaged tubular pole 8.5/9 mtr long, bracket for fixing street light and refixing the same including necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation size of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specified and directed.

2

-

-

... More
M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to pole including necessary form work slightly rounding or squaring, complete all as specified and as directed .

1.5

-

-

... More
M & L for PCC 1:4:8 type D2 with (using 40mm graded stone aggregate) as in foundation of poles etc, complete all as specified and as directed

5

-

-

... More
Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed.

40

-

-

... More
Supply & fixing of Cable Junction box of size 205 mm x 255 mm x 112 mm “weather proof”, for outdoor installation (with knockouts for cable entry) pole mounted front operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2 dead back, free standing, dust and vermin proof, switchboard with IP 66 protection with suitable for use 440 volts, 3 phase 4 wire 50 Hz system. The Board/Panel shall be made out of moduler POLYCARBONATE THERMOPLASTIC ENCLOSURES. The gasket material shall be Polyurethane; while the gasket shall be internally embedded. The manufacturer of board/panel shall submit a copy of test report in accordance with IEC60529. The Panel should be assembled at manufactures factory and Panel box having 6 Amp MCB (Make for MCB - C&S/Havells/indoasian and make for cable junction Box - Hensal Cat No - KF 2525 or equivalent of other make ), 25 Sq.mm Terminal Block (04 Nos) ,6 Sq.mm Disconnected Terminal (01 No), 4 Sq.mm Earth Terminal (01 No), gland for cable fixing both incoming & out going including set of MS clamp in suitable size with nut bolts and fixed to street light PCC /tubular pole including taking down old one complete all as directed.

30

-

-

... More
Supply and fix of LED street light fittings 70 watts pressure die cast aluminium housing with toughened glass and high power LEDs with option of secondary optic with IP-66 ingress protection with 4/5KV surge protection device, Manufacturers logo embossed on the housing for traceability (stickering/ printing not acceptable), system level efficacy of the luminarie is 120lm/W . The color temparature is arround 6500K with a color rendering index of 70. The luminaire of IP:66 protected with impact rasistence IK05 impact resistance, electronic driver compliant to IEC safety standards with power factor greater than 0.9, voltage variation range 120-270V, THD less than 20%, high and LED with individual peanut lens and lens plate for better optics. The product should be tested for IEC60598 safety standards, LM80 report for LED, entire product including taking down the old u/s one complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.

30

-

-

... More
Supply and fix of LED street light fittings 45 watts pressure die cast aluminium housing with toughened glass and high power LEDs with option of secondary optic with IP-66 ingress protection with 4/5KV surge protection device, Manufacturers logo embossed on the housing for traceability (stickering/ printing not acceptable), system level efficacy of the luminarie is 120lm/W . The color temparature is arround 6500K with a color rendering index of 70. The luminaire of IP:66 protected with impact rasistence IK05 impact resistance, electronic driver compliant to IEC safety standards with power factor is greater than 0.9, voltage variation range 120-270V, THD less than 20%, high and LED with individual peanut lens and len plate for better optics. The product should be tested for IEC60598 safety standards, LM80 report for LED, entire product including taking down the old u/s one complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.

15

-

-

... More
Material and labour for Painting of steel tubular pole 9.0 metre long, by applying one coat of aluminium paint after scraping / brushing and cleaning the rust on pole and street light bracket. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enameled paint (30 Cms Each). Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete all as specified and directed.

250

-

-

... More
Material and labour for cement base paint of applying one coat of cement RCC pole 9.0 metre long after scraping / brushing and cleaning the rust on pole and street light bracket to painted with one coat of Aluminium paint. Cement colour will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enameled paint (30 Cms Each) Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete, all as specified and directed.

200

-

-

... More
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :-

1

-

-

... More
(a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) GSM based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 06 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible. Make- Tricolite/ Kewintech/HPL

-

-

-

... More
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth in any type of soil for laying of cables up to proper level complete all as specified and directed.

688.5

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.

399.94

-

-

... More
Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed.

288.56

-

-

... More
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- (i) Excavated approved soil obtained from excavation under item No 33 shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness will be considered for payment.

247.86

-

-

... More
Material and labour for well burnt ‘B’ sub class bricks as protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed.

21.42

-

-

... More
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate complete all as specified and directed. Note :- The tenderer shall take into consideration for the following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material/rubbish out side MD land (iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.

50

-

-

... More
Supply only GI pipe light grade for cable protection of size 40mm bore complete with fitting complete all as specified and directed.

50

-

-

... More
Material and labour in repair for 3 ½ core 50 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed. Make :- Havells/Polycab/ RPG Asian

400

-

-

... More
Material and labour in repair for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian

600

-

-

... More
Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with black up to 1.5 meter from top of PCC 1:2:4 with 20 mm aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm aggregate foundation and coping as per TD drawing including dismantling damaged pole complete all as specified and as directed.Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. Tthe rate for above items shall be deemed to be inclusive in the quoted rate.

6

-

-

... More
Supplying & fixing of terminal Cable Junction box of size 155 mm x 210 mm x 92 mm “weather proof”, for outdoor installation (with knockouts for cable entry) pole mounted front operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2 dead back, free standing, dust and vermin proof, switchboard with IP 66 protection with suitable for use 440 volts, 3 phase 4 wire 50 Hz system. The Board/Panel shall be made out of moduler POLYCARBONATE THERMOPLASTIC ENCLOSURES. The gasket material shall be Polyurethane; while the gasket shall be internally embedded. The manufacturer of board/panel shall submit a copy of test report in accordance with IEC60529. The Panel should be assembled at manufactures factory and Panel box having 6 Amp MCB (Make for MCB - Indo Asian/Havells/C&S and make for Cable junction Box - Hensal Cat No - KF 1616 or equivalent of other make ), 16 Sq.mm Terminal Block (04 Nos) , 6 Sq.mm Disconnected Terminal (01 No) ,4 Sq.mm Earth Terminal (01 No) gland for cable fixing both incoming & out going including set of MS clamp in suitable size with nut bolts and fixed to street light PCC /tubular pole including taking down old one complete all as directed.

25

-

-

... More
Supply and fix in repair Time switches Digital 24 hour, 440 V three phase with contactor TP of rating 32 Amps and MCB TPN of rating 40A fitted in steel enclosure with necessary accessories to fixing RCC/steel tubular pole including bracket, nuts, bolts, washers etc. and making all necessary connections through connectors complete all as specified and as directed .Make : L&T/ Havells/ Indoasian

4

-

-

... More
Supply and fixing LED flood light fitting of 120 watts pressure die cast housing with IP66 protection with efficient high output emitter LED for better distribution with all accessories pre wired including necessary electric connection and bracket for fixing the fitting all including taking down unserviceable old fitting ,complete all as specified and directed.Make : Bajaj/Philips/CG/Halonix.

20

-

-

... More
Supply and fix of LED street light fittings 36 watts pressure die cast aluminium housing with toughened glass and high power LEDs with option of secondary optic with IP-66 ingress protection with 4/5KV surge protection device, Manufacturers logo embossed on the housing for traceability (stickering/ printing not acceptable), system level efficacy of the luminarie is 120lm/W . The color temparature is arround 6500K with a color rendering index of 70. The luminaire if IP:66 protected with impact rasistence IK05 impact resistance, electronic driver complaint to IEC safety standards with power factor is greater than 0.9, voltage variation range 120-270V, THD less than 20%, high and LED with individual peanut lens and lens plate for better optics. The product should be tested for IEC60598 safety standards, LM80 report for LED, entire product including taking down the old u/s one complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.

15

-

-

... More
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panel,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather, vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular encloser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-

1

-

-

... More
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 320 Amp, 36 KA - 01 No. (Incomer). (b) Change over switch 320 Amp, 4P front operated-01 No (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA - 01 No (O/G) (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 25 KA - 01 No (O/G) (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (g) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).

-

-

-

... More
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified . Make: Plaza/Polycab/ Finolex/Havells

300

-

-

... More
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified . Make: Plaza/Polycab/ Finolex/Havells

250

-

-

... More
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified . Make: Plaza/Polycab/ Finolex

150

-

-

... More
Servicing/ comprehensive maintenance of fire alarm system comprising of Smoke detection control panel Smoke detector (Photoelectric detection Technology), Conventional Fire Alarm control panel, flame detector, conventional manual call point with EN 54-11 : 2001 and LPCB, conventional sounder etc by attending fault testing of system, including preventive maintenance by replacing small spare parts complete all as specified and directed. Location : Gurukul, AFTC Officer Mess, CTI.

3

-

-

... More
Note for item No 63 :- (a) The repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The rate quoted shall be deemed to include for carried out all repairs noticed during the period. (c) The authorised service agency must be attended as and when called for urgent nature of repair of the fire aaram equipment's. (d) Checking of Alarm signal should not lost when primary power failure untill the alarm signal processed. (e) Checking of smoke detector sensibility (f) Checking of all circuit and loops. (g) Cleaning of dust particle from smoke detector, manual call point as per OEM recommendation.

-

-

-

... More
Supply & install in replacement smoke and heat detectors, photoelectric / optical type certified to EN 54 addressable with self built intelligent with connected accessories complying with optical chamber, cover, case molding, photodiode (transducer), infrared LED all as specified and directed. NOTE:- i). Metal junction box of suitable size for detector made of 16 SWG sheet steel is to be provided for mounting of detectors in the concrete mother ceiling / surface along with necessary gland and boxes duly painted with two coats of super enamelled paint over a coat of red oxide primer. ii) Rate of metal boxes shall be including in quoted rate of items. Make :- Ceasefire/ Visionic/ Universal (Rqvel)/ Honeywell or equivalent as per site requirement.

12

-

-

... More
Supply & install in replacement Fire Alarm Sounders / Sirens Electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtrs range. Make :- Ceasefire/ Visionic/ Universal (Ravel)/ Honeywell or equivalent as per site requirement.

2

-

-

... More
Supply & install 2 core solid conductor of size 1.5 Sqmm, as per IS-1554 PVC insulated & PVC sheathed, armoured cable FRLS down through non metallic PVC conduit of suitable size shall be properly clamped to the ceiling / surfaces including taking down of unserviceable cable and 'S' loop shall also be left where cables connect to sounders, panels and all the cables and wires shall be tagged for proper identification complete all as specified and directed.

250

-

-

... More
Supply & install in replacement Addressable monitor module. Make :- Ceasefire/ Visionic/ Universal (Ravel)/ Honeywell or equivalent as per site requirement.

2

-

-

... More
Supply & install in replacement Addressable electronic sounder cum strobe. Make :- Ceasefire/ Visionic/ Universal (Ravel)/ Honeywell or equivalent as per site requirement.

5

-

-

... More
Supply & install in replacement Addressable manual call point resettable type. Make :- Ceasefire/ Visionic/ Universal (Ravel)/ Honeywell or equivalent as per site requirement.

8

-

-

... More
Material and labour in repair for 4 core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.Make :- Havells/Polycab/ RPG Asian

700

-

-

... More
Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.Make :- Havells/Polycab/ RPG Asian

800

-

-

... More
Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.Make :- Havells/Polycab/ RPG Asian

750

-

-

... More
Material and labour in repair for 2 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.Make :- Havells/Polycab/ RPG Asian

350

-

-

... More
Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes of 80 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed.

30

-

-

... More
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25 - 50 Sqmm 3.5 core size of LT underground armoured cables etc complete all as specified and directed. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.

30

-

-

... More
Supply and fix street light terminal boxes factory made out of 1.6mm thick PVC sheet with hinges and locking arrangement of size 300x200x100mm housing in and including 25x4mm bus bar of suitable length fixed on porcelian insulator with proper size of screw and one No. of MCB SP 6 Amps, 240volts, in/out cable gland of suitable size fixed on street light pole with nut, bolt and washers etc, complete all as specified and directed.

30

-

-

... More
Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.

10

-

-

... More
Supply and fix in repair LED flood light fitting 200 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 200W etc complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.

8

-

-

... More
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor. Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, Ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed.

1

-

-

... More
(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible. Make- Tricolite/ Kewintech/HPL

-

-

-

... More
Suply and fix in repairs LED decorative post top lantern fitting 40W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection complete all as specified as directed. Make: CG/Bajaj / Philips/Halonix

10

-

-

... More
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 Amp by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.

24

-

-

... More
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.

-

-

-

... More
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contactor shall quote rate by considering all factors.

-

-

-

... More
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.

-

-

-

... More
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contactor before commencement of work.

-

-

-

... More
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.

-

-

-

... More
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).

-

-

-

... More
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.

-

-

-

... More
(viii) Earth resistance tester will be provided by the contactor. Tester should be calibrated from authorised company/ lab.

-

-

-

... More
(ix) Earthing shall be tested after completion of work by the contactor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.

-

-

-

... More
(x) The contactor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.

-

-

-

... More
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.

-

-

-

... More
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contactor has to redo or rectify at no extra cost to Govt till desired result is maintained.

-

-

-

... More
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contactor from final bill for the guarantee period.

-

-

-

... More
(xiv) The electrode shall carry manufacturer's name .

-

-

-

... More
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.

-

-

-

... More
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.

-

-

-

... More
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.

-

-

-

... More
(xviii) The contactor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.

-

-

-

... More
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.

-

-

-

... More
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.

25

-

-

... More
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit, complete including taking down, complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contactor shall submit load bearing capacity certificate from the manufacturer.

24

-

-

... More
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panel,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather, vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular encloser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-

1

-

-

... More
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No. (Incomer). (b) Change over switch 400 Amp, 4P front operated-01 No (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 320 Amp, 36 KA - 01 No (O/G) (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 25 KA - 01 No (O/G) (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (g) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). Note :- An amount of Rs 88625.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.