Military Engineer Services Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date20 Jan 2025
Closing Date10 Feb 2025
Tender Amount₹ 16,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking out burnt/ unserviceable sealed compressor Unit from Window type air conditioner and supply & replacement of factory sealed compressor unit, connecting refrigeration system after thorough flushing out the system with dry nitrogen, leak testing with nitrogen, vaccumising including neccessery brazing and welding arresting leakages and gas charging with refrigerant gas, testing, re-installing in its original position/location, connecting up all electrical connections, testing the complete unit all as specified and directed for Window type Air Conditioner 1.5 Ton. Notes :– (i)  Factory sealed compressor unit shall be of existing capacity and make. (ii)  Gas Charging shall be measured and paid separately under relevant item of this schedule.

1

-

-

... More
All as per item No.4 above but for Window type Air Conditioner 2.0 Ton

1

-

-

... More
M & L for removing the Window type Air conditioner from installed position leak testing and arresting the leakages in condensor/evaporator coil by brazing etc and refixing complete all as specified and drected for window type AC of 1.0 ton / 1.5 ton / 2.0 ton Capacity

3

-

-

... More
M & L for charging of refrigerant gas F-22 / R-22 /R-32 / R-134A to the Window type Air conditioner, water coolers, Refrigerator and Split type air conditioner after vaccumising the complete system and pressure test with nitrogen to ensure complete system leak proof, testing of air conditioners, water coolers for proper functioning and cooling effect to the entire satisfaction of Engineer in Charge complete all as specified and directed.

140

-

-

... More
Taking out the defective spare parts of window type AC of any capacity at its existing location by drawing out the AC from outer cover, supply and fixing new spare parts after thorough checking and rectification of defects in wiring circuits, pushing back the unit in its outer cover, testing and commissioning all as specified and directed. NOTE:- Supply of spare parts will be measured and paid separately under relevant items of this schedule.

5

-

-

... More
M & L for servicing of voltage Stabilizer 4 KVA single phase of make - Soft line or equivalent after strip opening covers, taking out the burnt out winding from the transformer, rewind with super enamelled copper winding wire, insulate properly, setting/testing of buck/boost relay, replacement of U/S electronic parts, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.

3

-

-

... More
M & L for servicing of Voltage Stabilizer 5 KVA single phase of make - Soft line or equivalent after strip opening covers, taking out the burnt out winding from the transformer, rewind with super enamelled copper winding wire, insulate properly, setting/testing of buck/boost relay, replacement of U/S electronic parts, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.

3

-

-

... More
M & L for complete servicing after pumping down Indoor/outdoor units of split AC complete by cleaning condenser/ Evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, applying oil in fan motor bushes, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, cleaning the air filter, connecting up all connections and testing after gas charging if required all as specified and directed for Split type Air Conditioner up to 1.0 Ton. Notes :- (i) The rate deemed includes for minor spares (ii) Gas shall be measured and paid separately under relevant item.

10

-

-

... More
All as per item No.11 above but for Split type Air Conditioner up to 1.5 Ton.

175

-

-

... More
All as per item No.11 above but for Split type Air Conditioner 2.0 Ton.

90

-

-

... More
All as per item No.11 above but for mega Split type Air Conditioner 2.5 Ton.

20

-

-

... More
All as per item No.11 above but for vertical type Air Conditioner 3.0 Ton

4

-

-

... More
Taking out burnt/ unserviceable sealed compressor Unit from split type air conditioner and supply & replacement of factory sealed compressor unit, connecting refrigeration system after thorough flushing out the system with dry nitrogen, leak testing with nitrogen, vaccumising and gas charging with refrigerant gas, testing, re-installing in its original position/location, connecting up all electrical connections, testing the complete unit all as directed for Split type Air Conditioner 1.5 Ton. Notes:- (i) Factory sealed compressor unit shall be of existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separately under relavant item

16

-

-

... More
All as per item No 16 above but for split type Air Conditioner 2.0 Ton

8

-

-

... More
All as per item No.16 above but for split type Air Conditioner 2.5 Ton

3

-

-

... More
M & L for removing the Split type Air conditioner outdoor unit/indoor unit from installed position, leak testing & arresting the leakages in condenser coil by brazing etc complete for Split type AC 1.5 ton / 2.0 ton / 2.5 ton. Note :- Gas Charging shall be mesasured and paid separately under relavant item

40

-

-

... More
Taking down the Unserviceable IDU blower motor and supplying and fixing IDU blower, motor capacity as per existing make all as specified and directed for 1.5 Tr split AC.

15

-

-

... More
Taking down the Unserviceable IDU blower motor and supplying and fixing IDU blower, motor capacity as per existing make all as directed for 2.0 Tr split AC.

15

-

-

... More
Taking down the Unserviceable Condensor fan blade and supplying and fixing as per existing make all as specified and directed for Condensor fan blade 1.5 TR.

10

-

-

... More
Taking down the Unserviceable Condensor fan blade and supplying and fixing as per existing make all as specified and directed for Condensor fan blade 2.0 TR.

10

-

-

... More
Taking down the Unserviceable Condensor fan motor and supplying and Fixing as per existing make all as specified and directed for 1.5 TR split AC.

10

-

-

... More
Taking down the Unserviceable Condensor fan motor and supplying and Fixing as per existing make all as specified and directed for 2.0 TR split AC.

10

-

-

... More
Supply only Starting Capacitor of 80 / 100 mfd complete all as specified and directed.

60

-

-

... More
Supply only Running Capacitor 36 / 45 mfd complete all as specified and directed.

60

-

-

... More
Supply only Potential Relay complete all as specified and directed.

5

-

-

... More
Supply only Thermostat complete all as specified and directed.

5

-

-

... More
Supply only Selector switch complete all as specified and directed.

3

-

-

... More
Supply only Control Knob complete all as specified and directed.

3

-

-

... More
Supply only capacitor 1.5 mfd to 4 mfd complete all as specified and directed.

30

-

-

... More
Supply only swing blade opertated motor for indoor split unit up to 2 ton complete all as specified and directed.

5

-

-

... More
Supply only Blower bush for indoor split unit up to 2 ton capacity complete all as specified and directed.

5

-

-

... More
S & F for AC timer suitable for controlling 2 Nos split AC complete all as specified and directed.

6

-

-

... More
S & F in replacement Copper refrigerant pipe Copper tube 1/2 " x 1/4" complete all as specified and directed.

42

-

-

... More
S & F in replacement Copper refrigerant pipe Copper tube 5/8 " x 1/4" complete all as specified and directed.

32

-

-

... More
Taking down perished Unserviceable insulation cover of refrigerent piping and Supplying & Fixing brutile rubber insulation for refrigerant pipings of suitable size complete all as specified and directed.

50

-

-

... More
Taking out existing Unserviceable Remote Control and supplying & fixing of Remote Control with cord wire for split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and directed.

14

-

-

... More
Taking out existing Unserviceable Air Filter and supplying & fixing of air filter for split type 1.5 ton / 2 ton /2.5 ton complete all as specified and directed.

40

-

-

... More
Removing existing Unserviceable fan motor of Condenser of Split type AC & rewinding of fan motor with suitable size of super enamelled copper winding wire etc complete all as specified and directed for Split type AC 1.5 ton / 2.0 ton / 2.5 ton.

15

-

-

... More
Supply Only Controller Card for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and directed.

4

-

-

... More
Supply Only Micro Controller with Embedded software for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and directed.

4

-

-

... More
Supply Only Relays for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and directed

5

-

-

... More
Supply Only Sensors with 5 mtr cable for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and directed.

5

-

-

... More
Supply Only Fuses for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and directed.

3

-

-

... More
S & F for PVC flexible Conduit pipe 20mm dia medium grade including all accessories for drain out pipe complete all as specified and directed.

50

-

-

... More
S & F inlet / outlet gas Valves suitable for split AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and directed.

3

-

-

... More
M & L for servicing water coolers of 40 / 80 ltrs Capacity Complete with cleaning condenser coil with air blower, wet servicing of condensor coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, applying oil in fan motor bushes, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing complete all as specified and directed

2

-

-

... More
M & L for servicing water coolers of 60 / 120 ltrs Capacity Complete with cleaning condenser coil with air blower, wet servicing of condensor coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, applying oil in fan motor bushes, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing complete all as specified and directed

2

-

-

... More
Taking out burnt / unserviceable sealed Compressor Unit from Water coolers 40 / 80 Ltrs per Hr Cooling capacity and Supply & replacement of factory sealed compressor unit, connecting refrigeration system after thoroughly flushing out the system and leak testing with CO2, vacuumising and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit complete all as specified and directed. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separately under relavant item

1

-

-

... More
Taking out burnt / unserviceable sealed Compressor Unit from Water coolers 60 / 120 Ltrs per Hr Cooling capacity and supply & replacement of factory sealed compressor unit, connecting refrigeration system after thoroughly flushing out the system and leak testing with CO2, vacuumising and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit complete all as specified and directed. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separately under relavent item

2

-

-

... More
M & L for removing the Water cooler from position and arresting the Leakages in condenser coil by brazing etc complete for Water cooler 40 / 60 Ltrs per Hr Cooling Capacity complete all as specified and directed

2

-

-

... More
Taking out Unserviceable starting capacitor and supplying & fixing of Starting capacitor suitable for Water cooler 40 Litres/Hr or 60 litres/Hr Cooling capacitor. Complete all as specified and directed.

4

-

-

... More
Taking out Unserviceable running capacitor and supplying & fixing of running capacitor suitable for Water cooler 40 Litres/Hr or 60 litres/Hr Cooling capacitor. Complete all as specified and directed.

3

-

-

... More
Taking out existing unserviceable thermostat and supplying & fixing of thermostat for Water cooler 40 Litres / Hr or 60 litres/ Hr Cooling capacity. Complete all as specified and directed.

3

-

-

... More
Taking out existing Unserviceable potential relay and supplying & fixing of Potential relay for Water cooler of 40Ltr/Hr or 60 Ltrs/Hr Cooling capacity. Complete all as specified and directed.

2

-

-

... More
Taking out Unserviceable OLP from Water cooler and supplying & fixing of OLP suitable for Compressor complete all as specified and directed.

1

-

-

... More
Taking out Unserviceble fan motor and supplying & fixing of fan motor (for Water Cooler Capacity 40 Ltrs/Hr or 60 Ltrs/Hr cooling capacity). Complete all as specified and directed.

2

-

-

... More
M & L for taking out defective fan blade of Water Cooler of any make & size and supplying and fixing of new Fan blade of same size and design as existing complete all as specified and directed.

2

-

-

... More
Taking Out defective PVC flexible connector and supplying & fixing of heavy duty PVC flexible connection, braided type, 15mm dia and 450mm long with nuts/ washers on either end complete all as specified and directed.

3

-

-

... More
M & L for servicing refrigerators up to 185 Lts capacity complete with cleaning condenser coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing all as specified and directed.

2

-

-

... More
M & L for Servicing Refrigerators up to 185 - 400 Lts capacity complete with cleaning condenser coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing all as specified and directed.

1

-

-

... More
Taking Out Unserviceable / burntout sealed Compressor Unit from Refrigerator and supply & replacement factory sealed compressor unit, connecting with copper piping by brazing & Copper tubing etc Complete all as specified and directed Up to 185 Lts capacity. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separtely under relavant item

1

-

-

... More
Taking Out Unserviceable / burntout Sealed Compressor Unit from Refrigerator and supply & replacement factory sealed compressor unit, connecting with copper piping by brazing & Copper tubing etc Complete all as specified and directed Up to 185 - 400 Lts capacity. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separtely under relavent item

2

-

-

... More
Removing of the Refrigerator from position and arresting the Leakages in Condenser Coil by brazing etc. complete all as specified and directed for refrigerator Up to 285 Ltrs.

1

-

-

... More
Taking Out existing Unserviceable Thermostat and supplying and fixing of Thermostat for Refrigerator 165 Ltrs / 285 ltrs complete all as specified and directed.

1

-

-

... More
Taking Out existing Unserviceable Box Type Relay and supplying and fixing of Box type Relay for Refrigerators 165 Ltrs / 285 Ltrs complete all as specified and directed.

1

-

-

... More
Taking Out existing Unserviceable OLP and supplying and fixing of OLP for Refrigerator 165 Ltrs / 285 ltrs complete all as specified and directed.

1

-

-

... More
S & F in replacement of metal clad switch socket, double pole and neutral enclosure with a two pin and earth plug and socket complete with One Single pole MCB SP 20 to 32 Amps and fixed concealed in walls Complete all as specified and as directed.

10

-

-

... More
Pumping down the Compressor before dismantling inner and outer units, disconnecting electric connections without any damage to existing system, reinstalling of inner and outer units in new locations with brackets and civil works (making holes in wall), complete finishing as required, assembling of inner & outer units including connection of suction and discharge pipes, testing connection etc with topping up refrigerant gas as required for maintaining pressure all as specified and directed.

5

-

-

... More
M & L for servicing Deep freezer upto 400 Lts capacity complete with cleaning condenser coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing all as specified and directed.

1

-

-

... More
Taking down of old u/s AC manager and supply & fix of AC load manager with built in programme for on/off of 2 Nos of 1.5 TR/2 TR capacity split type Acs suitable for operating on single phase 230 volts all as specified and directed.

5

-

-

... More
Taking down unserviceable MCB SP 20 to 32 Amp and supply and fixing in replacement of MCB SP 5 to 32 Amps rating, 10 KA Ç 'curve 240V, 50 Hz AC Complete all as specified and as directed.

20

-

-

... More
Taking down unserviceable MCB SPN 20 to 32 Amp and supply and fixing in replacement of MCB SPN 20 to 32 Amps rating, 10 KA Ç 'curve 240V, 50 Hz AC Complete all as specified and as directed.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.