Military Engineer Services Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date2 Nov 2018
Closing Date23 Nov 2018
Tender Amount₹ 34,00,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down carefully copper point wiring (light, fan, socket and power) complete(fittings to be measured separately) and making good surfaces of walls/floors etc complete all as specified and directed.

90

-

-

... More
M&L for surface point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & caping medium grade with all accessories on wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed cable 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:-

-

-

-

... More
(a) One light/fan point controlled by one switch

15

-

-

... More
(b) One 3 pin socket outlet 5 Amp on same board with other switches.

15

-

-

... More
(c) One 5 pin socket outlet 5 Amp on independent board.

15

-

-

... More
(d) One 3 pin 5 Amps socket outlet independent but below the switch board of light points in the same vertical plane

5

-

-

... More
All as per item No.5 above but with cables 2.5 Sqmm for one light/fan point on independent board and size of earthing cable 2.50 Sqmm

5

-

-

... More
All as per item No.5 above but with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board

5

-

-

... More
All as per item No.5 above but with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board but below the switch board of light points in the same vertical plane and size of earthing cable 2.50 Sqmm

5

-

-

... More
All as per item No.5 above but with cables 4 Sqmm for one 3 pin socket outlet 15 Amps on independent board and size of earthing cable 4 Sqmm

5

-

-

... More
M&L for concealed point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking through existing conduit, sunk pressed steel or cast iron terminal boxes and 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed cable 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:-

-

-

-

... More
(a) One light/fan point controlled by one switch

5

-

-

... More
(b) One 3 pin socket outlet 5 Amp on same board with other switches.

5

-

-

... More
(c) One 5 pin socket outlet 5 Amp on independent board.

5

-

-

... More
All as per item No.10 above but with cables 4.00 Sqmm for one 3 pin socket outlet 15 Amps on independent board and size of earthing cable 4 Sqmm

5

-

-

... More
Supply and fix in repairs ceiling fan regulator electronic five step type 230 Volts single phase, Make Anchor Cat No.14501 or equivalent in makes as specified herein after complete all as specified and directed

250

-

-

... More
Supply & fix in repairs MCB TPN, 40 to 63 Amps, ''C'' series 415 Volts, 3 phase, 10 KA capacity all as specified and directed.

25

-

-

... More
S & F in repairs MCB Single Pole Neutral, 6 to 32 Amps, ''C'' series 230 Volts, Single phase, 10 KA capacity all as specified and directed.

30

-

-

... More
Supply & fix in repairs MCB SP, 6 to 32 Amps, 'C' series 230 Volts, Single phase, 10 KA capacity all as specified and directed.

50

-

-

... More
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding, etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed. Note : (a) The unit rate quoted shall deemed to be included for minor items viz nuts, bolts split pin and rubber wheel etc. (b) Capacitor & bearing shall be measured and paid separately under relevant item of this schedule. (c) Rewinding of fan will be measured and paid for separately under relevant item of this schedule.

250

-

-

... More
Supply and fix in repairs capacitor of 2.5 mfd for ceiling fan/exhaust fan complete all as specified and directed.

300

-

-

... More
Supply and fix in repairs bearing No.6201/6202/6203 suitable for ceiling fan/exhaust fan complete all as directed.

400

-

-

... More
M & L for removing of burnt out winding wire from ceiling fan of any make and size of 1200 mm to 1400 mm sweep including cleaning of slots etc and rewinding with super enamelled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.

200

-

-

... More
Description all as per item No 19 above but exhaust fan of 300 mm sweep.

25

-

-

... More
Description all as per item No.19 above but exhaust fan of 380 to 450 mm sweep.

25

-

-

... More
S & F exhaust fan of 300mm sweep after assembling at site including electric connection from ceiling rose to connector with flexible cord twin core twisted copper of size 23/0.0076 and testing including taking down old defective exhaust fan and depositing the same to MES store yard complete all as specified and directed

5

-

-

... More
Supply & fix exhaust fan of size 380 mm sweep, metal body including electric connection from ceiling rose to connector with flexible cord twin core twisted copper of size 23/0.0076 and testing including taking down old defective exhaust fan and depositing the same to MES store yard complete all as specified and directed. Make : Usha Model No Turbo heavy duty or equivalent make in Bajaj/Crompton Greaves

5

-

-

... More
Supply & fix ceiling fan 1200 mm sweep including electric connection from ceiling rose to connector with flexible cord twin core twisted copper of size 23/0.0076 and testing including taking down old defective ceiling fan and depositing the same to MES store yard complete all as specified and directed. Make Crompton Greaves Model No Briz Air or equivlent make in Baja/Khaitan

50

-

-

... More
Taking down submain wiring cable any number of runs alongwith earth wire from the existing with or without concealed or surface conduit complete all as specified and directed.

250

-

-

... More
M&L for sub main wiring with 2 run of single core PVC insulated FRLS unsheathed suitable for 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking cable of size 4 sqmm and one run of 1100 V grade PVC insulated FRLS unsheathed 4 sqmm multistranded copper conductor cable 1100 Volts as in continuous earth drawn through existing conduit/casing capping complete for sub main wiring in walls/roof all as specified and directed. Note : Two run of cable 4 Sqmm and one run of 4 Sqmm cable shall be measured as one running meter unit

150

-

-

... More
M&L for sub main wiring with 2 run of single core PVC insulated FRLS unsheathed suitable for 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking cable of size 4.00 sqmm and one run of 1100 V grade PVC insulated FRLS unsheathed 4 sqmm multistranded copper conductor cable 1100 Volts as in continuous earth drawn in and including surface PVC conduit medium grade 20mm bore and accessories of suitable size complete for sub main wiring in walls/roof all as specified and directed. Note : Two run of cable 4.00 Sqmm, one run of 4 Sqmm cable and one run of PVC conduit pipe shall be measured as one running meter unit

100

-

-

... More
S & F in repairs MCB Distribution board, Single pole neutral 240 Volt, 8 way, double door powder coated steel sheet enclosure for surface mounting fitted with 200 Amps bus bar and din channel of make Havells cat part No DSSDBX0196 or equivalent in makes as specified here-in-after complete all as directed.

5

-

-

... More
S & F in repairs MCB Distribution board, Triple pole neutral 415 Volt, 4 way, horizontal double door powder coated steel sheet enclosure for surface mounting fitted with 200 Amps bus bar and din channel of make Havells cat part No DSSDBX0232 or equivalent in makes as specified here-in-aftercomplete all as directed.

5

-

-

... More
Supply and fix in repairs switch piano 5 Amps one way flush type, matching with existing make, ISI marked, all as specified and directed.

300

-

-

... More
Supply and fix in repairs decorative modular switch 6 Amps single pole flush type of make Anchor (Roma) Cat part No 21011 or equivalent in makes as specified here-in-after complete all as specified and directed.

50

-

-

... More
Supply and fix in repairs decorative modular fan regulator, electronic, five step type 230 Volts single phase of make Anchor (Roma) cat part No 21496 or equivalent in makes as specified here-in-after complete all as specified and directed.

25

-

-

... More
Supply and fix in repairs switch socket combination 2 in 1, 5 pin, 5 Amps flush type, matching with existing make ISI marked, all as specified and directed.

50

-

-

... More
Supply and fix in repairs switch socket combination 5 Amps/16 Amp, 5 in 1 flush type, multi purpose, matching with existing make ISI marked, all as specified and directed.

100

-

-

... More
Supply & fix in repair ceiling rose surface bakelite 65 x 50 mm three terminal, all as specified and directed.

50

-

-

... More
Supply and fix in repair lamp holder, insulated body with back plate suitable for angle / batten fitting all as specified and directed.

50

-

-

... More
Supply and fix in repairs bipin holder, rotary type suitable for tube light fittings all as directed.

50

-

-

... More
Supply and fix in repairs starter, 40 watt, 240 volt suitable for tubelight fitting all as directed.

200

-

-

... More
Supply and fix in repairs heavy duty electronic Ballast for fluorescent tube 36/40 watt of Make Bajaj Cat No. BJHF136/140P or equivalent in makes as specified herein after complete all as specified and directed

500

-

-

... More
S & F in repairs heavy duty vacuum pressure impregnated copper Ballast (VPIT) for CFL lamp 9/10/11/13/18 watt 240 volt all as directed.

50

-

-

... More
Fixing only flourescent tube rod 36/40/20 watt including taking down existing tube rod all as directed. Note :- Tube rod 20 / 36 / 40 watts will be issued under Sch 'B' free for fixing only.

1100

-

-

... More
Supply & fixing in repairs CFL lamp, Pin type, 9/10/11/13/18 watt, 240 volts complete all as specified and directed.

100

-

-

... More
Supply & fix integral sleek extruded polycarbonate batten for LED tube light with white acrylic cover suitable for 1 x 18watts LED tube light complete with all accessories and making electric connections and fixing arrangement complete all as specified and directed. Make : Bajaj model No BLRB-DB 118 or equivalent make specified here in after. Note : LED tube rod will be measured and paid seperately.

150

-

-

... More
Supply and fix in repairs LED tube rod 18/20 Watt, 6500 K, 1200 mm long complete all as specified and directed. Make : Bajaj cat No BLRB 18W CWC or equivalent specified here in after.

150

-

-

... More
Taking down carefully existing building security light/ store houses high /mid bay luminaires of any type, rectifying the defects by repairs /replacement of ballast/ignitor/lamp/capacitor and tightening the loose connection etc or replace new fitting & refixing in position complete all as directed. Note :- (i) GI pipe, MS flat iron with nut & bolts if used against this item will be measured & paid under respective items of this schedule . (ii) Ladder required for repairing of Street light fittings will be arranged by the contractor on his own arrangement and quoted rate is deemed to be included in this item. (iii) Labour elements for fixing of the choke/lamp of street light fitting is deemed to be included in this item and new choke/lamp shall be paid as supply only. Other spare parts of street light fitting i.e capacitor & ignitor will be measured under relevant item of this schedule as "supply and fixing" and in such cases the above items will not be measured and paid for.

30

-

-

... More
Supply only copper ballast for HPSV fitting of 70 watts complete all as specified and directed Make:- Havells, cat part No. LHBW07170036 or equivalent in Bajaj,Phillips,Crompton Greaves

15

-

-

... More
Supply only copper ballast for HPSV fitting of 150 watts complete all as specified and directed Make:- Havells, cat part No. LHBW20115036 or equivalent in Bajaj,Phillips,Crompton Greaves.

15

-

-

... More
Supply only copper ballast for HPSV fitting of 250 watts complete all as specified and directed Make:- Havells, cat part No. LHBW00125036 or equivalent in Bajaj,Phillips,Crompton Greaves.

15

-

-

... More
Supply only copper ballast for HPSV fitting of 400 watts complete all as specified and directed Make:- Havells, cat part No. LHGMCKENEAE1400 or equivalent in Bajaj,Phillips,Crompton Greaves.

8

-

-

... More
S&F in repairs Ignitor for HPSV fitting of 70,150, 250 & 400 watts complete all as specified and directed Make:- Havells, cat part No. LHNM05000D99 or equivalent make specified here in after.

50

-

-

... More
S & F in repairs energy saving environment friendly 150watt LED IP65 industrial medium bay luminaire complete all as specified and as directed. Make:- Havells Cat Part No SAUCERNEOP150W LED 75790DLTG or equivalent make specified here in after.

20

-

-

... More
S & F in repairs die cast aluminium IP66 flood light 200W LED luminaire complete all as specified and as directed. Make:- Havells Cat Part No JETAIRISFLS200W LED 730PSYMLTG or equivalent make specified here in after.

6

-

-

... More
Supply & fixing in repairs LED 45 Watt street light luminaire, pressure die cast housing with toughned glass, IP-66 protection with high power LEDs as light source and electronic driver of 45W capacity, making necessary connection of Make Havells cat No. ENDURA CITYLNEREXGENSL 45W LED 757SASYBOPC or equivalent make in Philips / Baja / C&S including bracket made out from 40/32 mm bore GI light grade pipe 1.5 mtr length, nuts bolts washer and clamp etc and two coats of aluminium paint over a coat of red oxide primer on mild steel work and taking down existing fitting complete all as specified and directed.

20

-

-

... More
Supply and fixing in repair LED lamp 18 watt, 230 volt, four pin PLS type suitable for existing decorative fittings/light fittings all as directed. Make: Havells Cat Part No PHOTONULTRAPLL419TL18WLED865SPC or equivalent make specified here in after.

20

-

-

... More
Supply only HPSV Elliptical coated lamp suitable for 70 watts complete all as specified and directed

15

-

-

... More
Supply only HPSV Elliptical coated lamp suitable for 150 watts complete all as specified and directed

15

-

-

... More
Supply only HPSV Elliptical coated lamp suitable for 250 watts complete all as specified and directed

15

-

-

... More
Supply only HPMV lamp suitable for 400 watts complete all as specified and directed

8

-

-

... More
Supply and fix in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 Amp single pole MCB 240 Volts all as specified and directed.

5

-

-

... More
Supply & fixing in repairs LED 15 Watt surface mounted 1x1 luminaire, made in white powder coated CRCA housing with LEDs, seamless front frame with white coloured flat acrylic cover including making necessary connection of Make Havells cat No. PLUTO SURFACE E1X1PLS15W LED 840S or equivalent make in Philips / Bajaj / C&S complete all as specified and directed.

30

-

-

... More
M & L for preparation of ceiling/exhaust fan body and blades by removing dust, rust, grease/oil spots etc and applying one coat of synthetic enamel paint, writing ser No and MES No with black paint on the format as approved by Engr-in-Charge complete all as specified and directed.

30

-

-

... More
M & L for preparation of ceiling/exhaust fan body and blades by removing dust, rust, grease/oil spots etc and applying two coats of synthetic enamel paint, writing ser No and MES No with black paint on the format as approved by Engr-in-Charge complete all as specified and directed.

30

-

-

... More
Sch 'A' Part-II (REPAIR/MAINTENANCE OF SPLIT ACS, WATER COOLERS, REFRIGERATION UNITS)

-

-

-

... More
M&L for rectification of defects and making functional Deep Freezer, split / floor mounted AC, water cooler & refrigerator of any capacity of existing makes incl rectification of minor defect such as tripping of MCBs, wherever necessary, rectifying loose electrical connections, making fresh connections in electric panel / connector etc, making functional defective drain pipe blockage/leakage etc, checking of functionality of compressor of any capacity etc complete all as specified and directed. Note :- Unit rate quoted shall be deemed to be included for maintaining proper record and obtain the signature of concerned user unit.

130

-

-

... More
M&L for periodical maintainance of split type AC of 1.5 / 2 Ton capacity including cleaning of overhead ceiling supported indoor unit complete, blower, outdoor unit, wiring system, cool air vent, cleaing including oiling / greasing of movable parts of indoor unit such as motor bearing etc, fresh electrical connections, checking insulation of wiring etc complete, all as specified and directed.

130

-

-

... More
All as per item No 65 above but for 3 ton capacity (2x1.5 Ton Out door unit one No and indoor unit 2 Nos)

10

-

-

... More
S & F in repairs copper condenser coil of size 20 x 30" / 22 x 31" x 1 rows suitable for 1.5/ 2.0 TR outdoor unit of split AC complete all as specified and as directed.

40

-

-

... More
Supply only F-22 refrigerant gas in sealed container.

120

-

-

... More
Supply only R-134A refrigerant gas in sealed container.

15

-

-

... More
Labour only for gas charging with required quantity of F-22 & R-134A refrigerant gas including all allied works such as vaccumising the complete system, soap leak test, nitrogen gas pressure test, replacement of flux, flare nut, dead plug, dead cap, brazing etc including necessary welding work, testing and commissioning upto satisfactory performance for the following :- Note :- Qty of gas will be measured and paid separately.

-

-

-

... More
(a) Refrigeration circuit of AC of capacity 1.5 Ton (Split/Window type AC) .

60

-

-

... More
(b) 2 Nos of Refrigeration circuit of 1.5 Ton each for split AC of capacity 3 Ton.

5

-

-

... More
(c) Refrigerator of any make, 280 Ltrs capacity

1

-

-

... More
(d) Refrigerator of any make, 310 Ltrs capacity

1

-

-

... More
(e) Water cooler of any make of 80 Ltr capacity and 40ltr/hr cooling capacity.

6

-

-

... More
(f) Water cooler of any make of 120/150 Ltr capacity and 40ltr/hr cooling capacity.

2

-

-

... More
(g) Refrigeratant circuit of AC capacity 2 Ton.

5

-

-

... More
(k) Deep freezer of any make of cap 310/410 Ltrs

2

-

-

... More
S&F in repairs reciprocating / rotary compressor hermetically sealed type single phase, 230 V suitable for split AC type of 1.5Ton capacity , factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.

30

-

-

... More
S&F in repairs reciprocating / rotary compressor hermetically sealed type single phase, 230 V suitable for split AC type of 2Ton capacity , factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.

3

-

-

... More
S&F in repairs compressor hermetically sealed type single phase, 230 V suitable for water cooler of 80 litre storage capacity and 40 litre per hour cooling capacity, factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.

1

-

-

... More
S&F in repairs compressor hermetically sealed type single phase, 230 V suitable for water cooler of 150 litre storage capacity and 40 litre per hour cooling capacity, factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.

1

-

-

... More
S&F in repairs compressor hermetically sealed type single phase, 230 V suitable for water cooler of 320 litre storage capacity and 40 litre per hour cooling capacity, factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.

1

-

-

... More
S&F in repairs compressor hermetically sealed type single phase, 230 V suitable for refrigerator of 210 litre capacity, factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.

1

-

-

... More
S&F in repairs compressor hermetically sealed type single phase, 230 V suitable for deep freezer of capacity 310/410 ltr, factory tested including pumping down refrigerant, brazing and flaring, topping up of refrigerant (labour only), connecting, testing and commissioning the compressor all as specified and directed.

1

-

-

... More
Supply & fix in repair fan motor single phase 240 Volts metallic body for out door unit of split AC suitable for 1.5/2 ton of existing RPM & setting with remote unit all as specified and directed.

20

-

-

... More
Supply & fix in repair fan motor single phase 240 Volts metallic body suitable for water cooler 80/150 litre storage capacity and 40 litre per hour cooling capacity of existing RPM all as specified and directed.

3

-

-

... More
Supply & fix in repair fan motor single phase 240 Volts metallic body for in door unit of split AC suitable for 1.5/2 ton of existing RPM & setting with remote unit all as specified and directed.

10

-

-

... More
S&F in repair fan blade assembly of alumunium frame for outdoor unit suitable for split AC of any capacity ,existing make all as specified and directed.

15

-

-

... More
M&L for taking down unserviceable fan blower motor of any HP capacity from outdoor unit of split type AC 1.5/2 TR capacity and rewinding motor with super enamelled copper wire , insulataing materials , varnishing, drying etc, replacement of bush, assembly etc suitable for exisitng make and fixing it back complete all as specified and directed.

20

-

-

... More
S&F in repairs PVC air filter for split type AC 1.5/2 Ton capacity complete all as specified.

20

-

-

... More
S&F in repairs pendent control assembly with cord and PC circuit suitable for existing split type AC of 1.5 Ton capacity complete all as specified & directed.

10

-

-

... More
S&F in repair LMS & overload relay assembly for 1.5/2 Ton compressor of Split type AC complete all as specified & directed.

10

-

-

... More
S&F in repair flexible cable 3 core, copper conductor 4 Sqmm complete all as specified & directed.

50

-

-

... More
S&F in repair of copper tube size 5/8" indoor suitable for split / floor mounted Acs including brazing complete all as specified & directed.

50

-

-

... More
S&F in repair of copper tube size 3/8" indoor suitable for split / floor mounted Acs including brazing complete all as specified & directed.

50

-

-

... More
S&F in repair copper tube insulation with heatlon or Superlon insulation material.

100

-

-

... More
Supply and fix in repairs capacitor 1.5 to 6 mfd, 230 Volt single phase complete all as specified & directed.

50

-

-

... More
Supply and fix in repairs capacitor 36-45 mfd, 230 Volt single phase complete all as specified & directed.

60

-

-

... More
Supply and fix in repairs capacitor 60 mfd, 230 Volt single phase complete all as specified & directed.

20

-

-

... More
Supply and fix in repairs contactor single phase model 3 TH 30 ,22 E suitable for out door unit 2x1.5 ton capacity of existing make all as specified & directed.

10

-

-

... More
Taking out carefully split type air conditioner of capacity 1.5/2 ton with frame as required and refixing the same at another site/new location including making the good distrubed surfaces as per existing specifications to entire satisfaction of Engineer-in-Charge.

15

-

-

... More
Supply and fixing/laying in repairs 20 mm bore PVC pipe to walls for drain out condensing water of split AC including cutting of floor/opening for making holes in walls and making good the same after fixing/laying pipe complete all as specified and directed

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.