Karnataka Urban Water Supply And Drainage Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Urban Water Supply And Drainage Board - KUWSDB Tender

Opening Date24 May 2021
Closing Date9 Jun 2021
Tender Amount₹ 65,67,867 
This is an estimated amount, exact amount may vary.
Notes
Download

Summary

Nagarothana (municipality-3) Scheme To Madikeri City Part-a: Construction 6.0m X 4.0m Size Pumphouse Near Kstdc Glsr And 4.0m X 3.0m Size Pumphouse And Control Panel Room Near Existing 5.0ll Capacity Glsr At Yelepete In Madikeri City

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and constructing granite / trap / basalt size stone masonry in foundation with cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications with all lead and lift as directed by the engineer in charge

7.53

-

45332.11

... More
Providing and constructing granite / trap / basalt size stone masonry in basement with cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications with all lead and lift as directed by the engineer in charge

4.24

-

31100.74

... More
Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320 kgs,with 20mm and down size graded granite metal, Coarse aggregates @ 0.690 cum and Fine aggregate @ 0.460 cum, with superplastisiser @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation plinth and ground floor level for roof slabs, staircase, lintles, retaining walls, return walls, walls ( any thickness ) including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications with all lead and lift as directed by the engineer in charge

19.68

-

135747.13

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons with all lead and lift as directed by the engineer in charge

10.8

-

3181.25

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specificaitons with all lead and lift as directed by the engineer in charge

70.26

-

22977.83

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness upto 200 mm including cost of all materials, labour complete as per specificaitons with all lead and lift as directed by the engineer in charge

33.81

-

15449.82

... More
Providing and laying in position reinforced cement concrete of mix M20 with OPC cement @ 24 kgs,with 12mm and down size graded granite metal, Coarse aggregates @ 0.5175cum and Fine aggregate @ 0.345cum, with superplastisiser @ 0.225lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete as per specifications with all lead and lift as directed by the engineer in charge

7.3

-

3883.38

... More
Providing and removing centering, shuttering, strutting, propping etc., for chajjas, corbels etc., including edges including cost of all materials, labour complete as per specificaiton with all lead and lift as directed by the engineer in charge

6.18

-

2277.21

... More
Providing T.M.T. steel reinforcement for R.C.C. work including straightening cutting, bending, hooking, placing in position, lapping and (or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications with all lead and lift as directed by the engineer in charge

2.7

-

214044.77

... More
Providing and constructing brunt brick masonry with approved quality of modular bricks of standard size of class designation 5.0 Newton per sqmm (table moulded) with cement mortar 1:4 for basement and superstructure including cost of all materials, lobour charges, scaffolding, curing complete as per specifications with all lead and lift as directed by the engineer in charge

26.31

-

246932.77

... More
Providing 18mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead and lift as directed by the engineer in charge

178.33

-

49502.62

... More
Providing 12mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering,: Providing and removing scaffolding, including cost of materials, labour, curing including lime rendering complete as per specifications with all lead and lift as directed by the engineer in charge

90.85

-

19854.36

... More
Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering,: Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.including lime rendering with all lead and lift as directed by the engineer in charge

33.81

-

8627.3

... More
Providing and fixing Pull and Push type rolling shutters of approved make out of 18 gauge ,75mm wide cold rolled steel lathes of convex corrugations, with side guides and bottom rails, with interlocking arrangements for steel lathes by means of alternate and clips, suspensions shaft with high tension coil types springs two numbers, mounted on specially designed pipe shaft, with bracket paltes, guide channels, ball bearing arrangements, for inside and outside locking with push and pull operations complete including pulling hooks, 4 Nos handles with all fittings accessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM of machinery complete as per specifications with all lead and lift as directed by the engineer in charge

5

-

14599.2

... More
Providing and fixing Top covers made out of 20 gauge M.S sheet over pull and push rolling shutters bent to shape including cost of red lead primer coat of painting, materials, labour, HOM of machinery complete as per specifications with all lead and lift as directed by the engineer in charge

2.5

-

1349.6

... More
Providing and fixing in position alluminium windows and ventilators as per approved drawing with sliding shutters using double track window frame section of size 61.85x31.75mm. with thick, bottom section weight 0.69 Kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side section 40mmx26.7mm. 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain grass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdiving the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification complete with all lead and lift as directed by the engineer in charge '-do- using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality.

12.6

-

61471.87

... More
Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M15 cement concrete, using broken granite metal of 12.5mm nominal size and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide ( using 3.5 kg of red oxide per 50 kg of cement ) finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as per specifications with all lead and lift as directed by the engineer in charge

24

-

18452.64

... More
Providing and finishing external walls in two coats with water proof cement paint with primer of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foriegn matter cost of materials, labour, complete as per specification with all lead and lift as directed by the engineer in charge

178.33

-

20372.42

... More
Providing and apllying two coats with plastic emulsion paint of approved brand and shade on wall surface to give an even approved shade including priming coat after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications with all lead and lift as directed by the engineer in charge

90.85

-

9157.68

... More
-do- for painting with one coat plastic emulsion paint of approved brand and shade on ceiling and / or sloping roof as per specifications with all lead and lift as directed by the engineer in charge

33.81

-

3597.38

... More
Providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications with all lead and lift as directed by the engineer in charge

12.6

-

1368.86

... More
Providing internal electrification to pumphouse near KSTDC GLSR in Madikeri city Supplying and wiring adopting loop system in existing PVC Conduit Casing capping using 2x1.5 Sq Mm (Phase & Neutral) & 1 x 1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (conforming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lift as directed by the engineer in charge a) Short point upto 3mtrs from Tapping point to outlet via switch

2

-

400

... More
Supplying and wiring adopting loop system in existing PVC Conduit Casing capping using 2x1.5 Sq Mm (Phase & Neutral) & 1 x 1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (conforming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lift as directed by the engineer in charge a) medium point 3mtrs upto 6mtrs from Tapping point to outlet via switch

2

-

550

... More
Supplying and wiring adopting loop system in existing PVC Conduit Casing capping using 2x1.5 Sq Mm (Phase & Neutral) & 1 x 1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (conforming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lift as directed by the engineer in charge a) Long point 6mtrs upto 10mtrs from Tapping point to outlet via switch

2

-

800

... More
Supplying 6A flush/projected type socket and 6 amps flush/projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required with all lead and lift as directed by the engineer in charge

2

-

224

... More
Supplying and fixing/ replacing of 6/16/32Amps electrical accessories on existing switch board with all lead and lift as directed by the engineer in charge a) 32 Amphs Flush / projected type DP switch

2

-

364

... More
Supplying & fixing of Surface mounting type retrofit type - LED tube .......W comprising of LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition with all lead and lift as directed by the engineer in charge Polycarbonate/OPAL Acrylic Casing 18W-20W (T8)

2

-

850

... More
Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plus screws etc.,with all lead and lift as directed by the engineer in charge (b) For 12" x 12" x 2mm

2

-

300

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with shoort circuit breaking capacity of 10K and complte wiring as required with all lead and lift as directed by the engineer in charge 6- 32amps SP

2

-

868

... More
Supplying and fixing regular MCB distribution boards on wall/woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable using type capacity MCBs single phase/3 phase/single door with powder coating painting etc., complete with all lead and lift as directed by the engineer in charge Single door 12way TP & N

1

-

777

... More
Supplying, fixing wiring earth electrode for grounding conduits, IC cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit. The pit should be filled with equal proportion of salt and charcaol 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3 of i:732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through hloes of 122mm dia with all lead and lift as directed by the engineer in charge

1

-

2999.7

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments with all lead and lift as directed by the engineer in charge Group A. 1.0 Sqmm

100

-

1400

... More
-do- 1.5 Sqmm

75

-

1537.5

... More
-do- 2.5 Sqmm

50

-

1600

... More
-do- 4.0 Sqmm

50

-

2250

... More
Supplying and Fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at as interval of 300mm etc as required with all lead and lift as directed by the engineer in charge. 25 mm dia

140

-

3360

... More
Extra for supplying and fixing 4mm thick white plastic and covering for junction boxes of size 110 mm dia conduit using necessary machine screws with all lead and lift as directed by the engineer in charge 110 mm dia

20

-

180

... More
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>130lm/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source with all lead and lift as directed by the engineer in charge LED Streetlight 70watts

2

-

10960

... More
Supplying and fixing of 25mm dia class A GI pipe bracket up to 2 mtsr long bent at suitable angle and fixing to this bracket 1x40/ 2x40 watts florescent tube street light fitting of all capacities to GI or CI or rail or RCC pole/ wall using suitable clamps, bolts and nuts and wirring using suitable capacity wires complete with all lead and lift as directed by the engineer in charge Using 25mm dia GI pipe

2

-

1550

... More
Supply of 6 amps one way SP Switch with all lead and lift as directed by the engineer in charge Group A.

2

-

23

... More
Supplying of 6A Universal Socket with all lead and lift as directed by the engineer in charge Group A.

4

-

648

... More
Supplying & Fixing of Procelain Fuse Channel With cut out on existing wooden /panel using necessary nuts , bolts and washers etc., complete with all lead and lift as directed by the engineer in charge 32 Amps

3

-

522

... More
Construction of 4.0m x 3.0m size pumphouse and control panel room near existing 5.0LL capacity GLSR at Yelepete Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with all lead and lift after breaking of clods complete as per specifications as directed by the engineer in charge

17.17

-

5749.89

... More
Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with all lead and lift after breaking of clods complete as per specifications with all lead and lift as directed by the engineer in charge

4.29

-

2152.55

... More
Providing and laying in position plain cement concrete of mix 1:2:4 with OPC cement @ 240 kgs, with 40mm and down size graded granite metal coarse aggregates @ 0.878 cum and fine aggregates @ 0.459cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curring complete as per specifications with all lead and lift as directed by the engineer in charge

3.31

-

21497.16

... More
Providing and constructing granite / trap / basalt size stone masonry in foundation with cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications with all lead and lift as directed by the engineer in charge

2.69

-

16194.34

... More
Providing and constructing granite / trap / basalt size stone masonry in basement with cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications with all lead and lift as directed by the engineer in charge

2.01

-

14743.51

... More
Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320 kgs,with 20mm and down size graded granite metal, Coarse aggregates @ 0.690 cum and Fine aggregate @ 0.460 cum, with superplastisiser @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation plinth and ground floor level for roof slabs, staircase, lintles, retaining walls, return walls, walls ( any thickness ) including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications with all lead and lift as directed by the engineer in charge

12.44

-

85807.64

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons with all lead and lift as directed by the engineer in charge

7.2

-

2120.83

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specificaitons with all lead and lift as directed by the engineer in charge

50.46

-

16502.44

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness upto 200 mm including cost of all materials, labour complete as per specificaitons with all lead and lift as directed by the engineer in charge

19.11

-

8732.51

... More
Providing and laying in position reinforced cement concrete of mix M20 with OPC cement @ 24 kgs,with 12mm and down size graded granite metal, Coarse aggregates @ 0.5175cum and Fine aggregate @ 0.345cum, with superplastisiser @ 0.225lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete as per specifications with all lead and lift as directed by the engineer in charge

7.5

-

3989.78

... More
Providing and removing centering, shuttering, strutting, propping etc., for chajjas, corbels etc., including edges including cost of all materials, labour complete as per specificaiton with all lead and lift as directed by the engineer in charge

3.96

-

1459.18

... More
Providing T.M.T. steel reinforcement for R.C.C. work including straightening cutting, bending, hooking, placing in position, lapping and (or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications with all lead and lift as directed by the engineer in charge

1.99

-

157758.92

... More
Providing and constructing brunt brick masonry with approved quality of modular bricks of standard size of class designation 5.0 Newton per sqmm (table moulded) with cement mortar 1:4 for basement and superstructure including cost of all materials, lobour charges, scaffolding, curing complete as per specifications with all lead and lift as directed by the engineer in charge

6.8

-

63821.47

... More
Providing 18mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead and lift as directed by the engineer in charge

146.32

-

40616.97

... More
Providing 12mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering,: Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.including lime rendering with all lead and lift as directed by the engineer in charge

40.3

-

8807.16

... More
Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering,: Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.including lime rendering with all lead and lift as directed by the engineer in charge

19.11

-

4876.3

... More
Providing and fixing Pull and Push type rolling shutters of approved make out of 18 gauge ,75mm wide cold rolled steel lathes of convex corrugations, with side guides and bottom rails, with interlocking arrangements for steel lathes by means of alternate and clips, suspensions shaft with high tension coil types springs two numbers, mounted on specially designed pipe shaft, with bracket paltes, guide channels, ball bearing arrangements, for inside and outside locking with push and pull operations complete including pulling hooks, 4 Nos handles with all fittings accessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM of machinery complete as per specifications with all lead and lift as directed by the engineer in charge

5

-

14599.2

... More
Providing and fixing Top covers made out of 20 gauge M.S sheet over pull and push rolling shutters bent to shape including cost of red lead primer coat of painting, materials, labour, HOM of machinery complete as per specifications with all lead and lift as directed by the engineer in charge

2

-

1079.68

... More
Providing and fixing in position alluminium windows and ventilators as per approved drawing with sliding shutters using double track window frame section of size 61.85x31.75mm. with thick, bottom section weight 0.69 Kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side section 40mmx26.7mm. 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain grass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdiving the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification with all lead and lift as directed by the engineer in charge '-do- using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality.

7.92

-

38639.46

... More
Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M15 cement concrete, using broken granite metal of 12.5mm nominal size and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide ( using 3.5 kg of red oxide per 50 kg of cement ) finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as per specifications with all lead and lift as directed by the engineer in charge

24

-

18452.64

... More
Providing and finishing external walls in two coats with water proof cement paint with primer of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foriegn matter cost of materials, labour, complete as per Vspecification with all lead and lift as directed by the engineer in charge

146.32

-

16715.6

... More
Providing and apllying two coats with plastic emulsion paint of approved brand and shade on wall surface to give an even approved shade including priming coat after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications with all lead and lift as directed by the engineer in charge

40.3

-

4062.24

... More
-do- for painting with one coat plastic emulsion paint of approved brand and shade on ceiling and / or sloping roof as per specifications with all lead and lift as directed by the engineer in charge

19.11

-

2033.3

... More
Providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications with all lead and lift as directed by the engineer in charge

7.92

-

860.43

... More
Repairs to existing 6x4m size pumphouse and 5.00LL capacity GLSR near Yelepete Cleaning and washing of stone masonry wall surface with nitric acid including cost of materials, labour, complete as per specifications with all lead and lift as directed by the engineer in charge

246.6

-

1380.96

... More
Providing and applying two coats with plastic emulsion paint of approved brand and shade on wall surface to give an even approved shade including priming coat after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications with all lead and lift as directed by the engineer in charge

105

-

10584

... More
Providing two coats of water proof cement painting of approved colour and shade over one coat of primer including necessary seaffolding and scraping of old paint and stain with wire brushes and cleaning of paint stains wherever necessary for old R.C.C. over head tank. with all lead & lifts etc., complete with all lead and lift as directed by the engineer in charge

216.8

-

44920.96

... More
Clearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, by manual means, in area of light jungle, removal of stumps, disposal of unserviceable materials, stacking of serviceable materials labour charges complete as per specifications with all lead and lift as directed by the engineer in charge

720

-

8064

... More
Earth work for lowering and levelling the ground other than foundation works by mechanical means upto 3.00 depth, including providing shoring strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required & utilising/transporting the remaining earth upto 1.00 km lead. Including the cost of labour & HOM as per drawing and technical specification with all lead and lift as directed by the engineer in charge

523.78

-

35198.02

... More
Providing and fixing in position alluminium windows and ventilators as per approved drawing with sliding shutters using double track window frame section of size 61.85x31.75mm. with thick, bottom section weight 0.69 Kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side section 40mmx26.7mm. 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain grass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdiving the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification with all lead and lift as directed by the engineer in charge '-do- using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality.

8.88

-

43323.03

... More
Providing and fixing Pull and Push type rolling shutters of approved make out of 18 gauge ,75mm wide cold rolled steel lathes of convex corrugations, with side guides and bottom rails, with interlocking arrangements for steel lathes by means of alternate and clips, suspensions shaft with high tension coil types springs two numbers, mounted on specially designed pipe shaft, with bracket paltes, guide channels, ball bearing arrangements, for inside and outside locking with push and pull operations complete including pulling hooks, 4 Nos handles with all fittings accessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM of machinery complete as per specifications with all lead and lift as directed by the engineer in charge

7.5

-

21898.8

... More
Providing and fixing Top covers made out of 20 gauge M.S sheet over pull and push rolling shutters bent to shape including cost of red lead primer coat of painting, materials, labour, HOM of machinery complete as per specifications with all lead and lift as directed by the engineer in charge

3

-

1619.52

... More
Providing and applying black japan paint one coat (excluding priming coat ) on previously painted steel or other metal surface brushing to give an even shade after cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, complete as per specifications with all lead and lift as directed by the engineer in charge

11.78

-

606.91

... More
Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per sqm over 50mm thick sand bed (average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and HOM of machineries complete as per specifications with all lead and lift as directed by the engineer in charge

100.5

-

118863.36

... More
Providing internal electrification to pumphouse and control panel room near existing 5.0LL capacity GLSR at Yelepete Supplying and wiring adopting loop system in existing PVC Conduit Casing capping using 2x1.5 Sq Mm (Phase & Neutral) & 1 x 1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (conforming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lift as directed by the engineer in charge a) Short point upto 3mtrs from Tapping point to outlet via switch

2

-

400

... More
Supplying and wiring adopting loop system in existing PVC Conduit Casing capping using 2x1.5 Sq Mm (Phase & Neutral) & 1 x 1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (conforming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lift as directed by the engineer in charge a) medium point 3mtrs upto 6mtrs from Tapping point to outlet via switch

2

-

550

... More
Supplying and wiring adopting loop system in existing PVC Conduit Casing capping using 2x1.5 Sq Mm (Phase & Neutral) & 1 x 1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (conforming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lift as directed by the engineer in charge a) Long point 6mtrs upto 10mtrs from Tapping point to outlet via switch

2

-

800

... More
Supplying 6A flush/projected type socket and 6 amps flush/projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required with all lead and lift as directed by the engineer in charge

2

-

224

... More
Supplying and fixing/ replacing of 6/16/32Amps electrical accessories on existing switch board with all lead and lift as directed by the engineer in charge a) 32 Amphs Flush / projected type DP switch

2

-

364

... More
Supplying & fixing of Surface mounting type retrofit type - LED tube .......W comprising of LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition with all lead and lift as directed by the engineer in charge Polycarbonate/OPAL Acrylic Casing 18W-20W (T8)

2

-

850

... More
Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plus screws etc.,with all lead and lift as directed by the engineer in charge (b) For 12" x 12" x 2mm

2

-

300

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with shoort circuit breaking capacity of 10K and complte wiring as required with all lead and lift as directed by the engineer in charge 6- 32amps SP

2

-

868

... More
Supplying and fixing regular MCB distribution boards on wall/woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable using type capacity MCBs single phase/3 phase/single door with powder coating painting etc., complete with all lead and lift as directed by the engineer in charge Single door 12way TP & N

1

-

777

... More
Supplying, fixing wiring earth electrode for grounding conduits, IC cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit. The pit should be filled with equal proportion of salt and charcaol 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3 of i:732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through hloes of 122mm dia with all lead and lift as directed by the engineer in charge

1

-

2999.7

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments with all lead and lift as directed by the engineer in charge Group A. 1.0 Sqmm

100

-

1400

... More
-do- 1.5 Sqmm

75

-

1537.5

... More
-do- 2.5 Sqmm

50

-

1600

... More
-do- 4.0 Sqmm

50

-

2250

... More
Supplying and Fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at as interval of 300mm etc as required with all lead and lift as directed by the engineer in charge. 25 mm dia

140

-

3360

... More
Extra for supplying and fixing 4mm thick white plastic and covering for junction boxes of size 110 mm dia conduit using necessary machine screws with all lead and lift as directed by the engineer in charge 110 mm dia

20

-

180

... More
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>130lm/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source with all lead and lift as directed by the engineer in charge LED Streetlight 70watts

2

-

10960

... More
Supplying and fixing of 25mm dia class A GI pipe bracket up to 2 mtsr long bent at suitable angle and fixing to this bracket 1x40/ 2x40 watts florescent tube street light fitting of all capacities to GI or CI or rail or RCC pole/ wall using suitable clamps, bolts and nuts and wirring using suitable capacity wires complete with all lead and lift as directed by the engineer in charge Using 25mm dia GI pipe

2

-

1550

... More
Supply of 6 amps one way SP Switch with all lead and lift as directed by the engineer in charge Group A.

2

-

23

... More
Supplying of 6A Universal Socket with all lead and lift as directed by the engineer in charge Group A.

4

-

648

... More
Supplying & Fixing of Procelain Fuse Channel With cut out on existing wooden /panel using necessary nuts , bolts and washers etc., complete with all lead and lift as directed by the engineer in charge 32 Amps

3

-

522

... More
PART-B: Supply, erection, electrification and commissioning of 2 nos. Of 40 HP or suitable HP centrifugal pumpsets to pump pure water from 5.00 LL capacity GLSR to proposed 12.50LL capacity GLSR near Ukkuda and Supply, erection, electrification and commissioning of 2 nos. Of 30 HP or suitable HP centrifugal pumpsets to pump pure water from 1.50 LL capacity GLSR near KSTDC to proposed 7.50LL capacity GLSR near Sudarshan circle. Supply, erection, electrification and commissioning of 2 nos. Of 40 HP or suitable HP centrifugal pumpsets with all allied accessories to pump pure water from 5.00 LL capacity GLSR to proposed 12.50LL capacity GLSR near Ukkuda. Pumps: Supply and delivery at site brand new, best efficient IS/BIS/CPRI approved make horizontal split case centrifugal pump confirming to the latest ISS 1520 and IS5120 & the following description. a) Duty Condition: Capable of delivering 30.21 lps of treated/turbid water containing turbidity up to 1000/ 100000 ppm against a total head of 61.00mtrs b) Speed: Duty condition should be met at 1450 RPM. c) Shutt off head: Min 110 % & Max 130 % of the specified head. d) Material of construction: 1) Casing- Cast Iron 2) Impellor - CF 8M 3) Shaft- Stainless steel shaft- SS 410 4) Stuffing Box- Graphite Asbestos packing 5) Wear Rings- Phosphor Bronze 6) Gland- Cast Iron 7) Inter Stage Ring- Phosphor Bronze 8) Shaft Sleeve & Nuts- SS 410 9) Neck ring- SS 410 e) Driving end bearing: Grease lubricated roller/ball/ journal bearing f) Non driving end bearing: Grease lubricated deep groove ball bearing as well as journal bearing or deep groove ball bearing only. g) Coupling: Suitable size vibration proof flexible coupling with coupling guard, as recommended by the manufacturer of pump, for coupling to motor. h) Base plate: Heavy duty common CI/MS base plate for pump and motor wth suitable `I' section girders, channels, plates, bolts & nuts etc. NOTE: (1) The duty condition of the pump should be at BEP or to the left of the BEP. (2) The pump is required to work at an altitude of 800m. above MSL and at a max. ambient temperature of 45 degree C. (3) The Board reserves the right to select any stipulated make of pump. (4) The loading for low efficient pump wll be done based on the excess power consumed by it over a period of 15 years, when compared to the best efficient pump with all lead and lift as directed by the engineer in charge

2

-

519750

... More
Induction Motor: Minimum 40 HP or suitable HP Make approved by the Board Horizontal mounted TEFC, squirrel cage induction motor, 1500 RPM motor for continuous duty conforming to IEC60034 for operation on 3 ph, 50 Hz. 430 volts. a) Protection: IP 55 b) Insulation: `F' class e) Ambient temperature: Upto 45 Degree C d) Cushion: 20 % more than maximum power required by the pump and capable of providing rated output upto + or - 10% voltage variation and/or + or - 3% frequency variation or combination of Both. e) Driving end bearing: Grease lubricated roller bearing f) Non driving end bearing: Grease lubrcated ball bearing

2

-

340607.14

... More
DOUBLE FLANGED PIPES & SPECIALS: Manufacturing, providing, transporting, rolling, lowering, laying and jointing, testing and commissioning of MS specials of minimum 8 mm thick conforming to IS 7322:1985 with latest amendments, perfect linking and welding of joints to correct position including cost and conveyance of materials with all lead and lifts, cost of all labour and giving satisfactory hydraulic test as per IS 3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc., complete as per detailed specifications with inside lining two coats of food grade epoxy painting of approved make with each coat of 250 micron, thick (after dry) over one coat of food grade epoxy primer of approved make with minimum of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of pipes for the following category to suit PSC/ MS/ CI/ AC/ DI/ PVC pipes. The weight of the MS shell only be considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (contractor will make his own arrangements for procuring water for testing) with all lead and lift as directed by the engineer in charge 1. For bends, Tail pieces, Reducers, Test gaps & Tees: upto & inclusive of 500mm dia pipe I. For suction/Deliveryside and other specials: 200/125mm dia or suitable dia MS pipes, specials and flanges etc.,

2450

-

447272

... More
d) Minimum 250mm dia or suitable size flanged foot valve of Kirloskar make with all lead and lift as directed by the engineer in charge

2

-

42280

... More
Dismantling joint Providing, installing at site of works and testing Dismantling joints in pump delivery pipe line complete, suitable for following specifications and confirming to detailed specifications with all lead and lift as directed by the engineer in charge

2

-

25600

... More
Sluice valve: Supply, & delivery of resilient sealed soft sealing sluice valves with body, bonnet of ductile iron of Grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of Vacuum tight and 100% leak proff with face dimensions as per BS 5163-89/ IS 14846-2000/ DIN3202 F4\f5 . The stem Sealing should be with Torodial sealing rings ( Minimum 2 O-rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The Valves shall be supplied with suitable size galvanised bolts and nuts of requied numbers of GKW/ KITO/NLXO/TECHMAN any other equivalent international approved brand with all lead and lift as directed by the engineer in charge '-do- 150mm dia PN 16 dia

2

-

38014.72

... More
-do- 80 mm dia for pressure relief valve

1

-

8582.12

... More
Ductile Iron check valves: Supply and fixing of ductile iron double flanged swing check vav with slanted seat or with lever weight with straight disc, wi metallic corrosion proof and wear resistant seat faces with nick overlay micro - finished/ Integral seat with body and disc in Duct Iron in GGG 40/50 shaft of stainless steel and bearings of zinc fr bronze and surface protection with epoxy liquid of GSK quality with all lead and lift as directed by the engineer in charge 150mm dia PN 16

2

-

45816.72

... More
PRESSURE RELIEF VALVES : Supply, delivery and erection of site brand new DOROT ( S-100) /BERMAD/ ERHARD make pressure relief valve of 80mm dia with maximum permisable pressure 10 Kg/cm2 with the following specifications with all lead and lift as directed by the engineer in charge 1. Valve should have direct sealing diaphragm activated by line pressure and controlled by 2 way diaphragm operated adjustable pilot valve. 2. Valve should be installed on a Tee junction, which should modulates automatically to maintain present inlet pressure and releive the excess pressure out of the network. MATERIAL OF CONSTRUCTION : 1. Body and Bonnet - Ductile Iron ISO 1083 Grade 450-10. 2. Diaphragm - Natural rubber (standard). 3. Spring - SS 302. 4. Pilot valve - Brass ISO 426. 5. Coating - Electrically applied over baked polyster. 6. End connection - Flanges BS or IS. The outlet of pressure sustaining valve should be connected to sump using MS pipes and fittings.

1

-

99540

... More
Pressure Gauge : Supply and delivery at site Air master/Gurusons/Forbes Marshal make glycerene filled Stainless steel pressure gauge of 150mm dia suitable for the above pumpsets with nipple, stop cock & two way cock for cleaning & necessary length of copper tubing with all lead and lift as directed by the engineer in charge

2

-

4000

... More
CONTROL PANEL BOARD UNITS: Supply and delivery at site brand new Board approved make industrial type floor mounting free standing cubicle type control panel board unit of adequate size to fix all the following items and suitable for operation on 3 phase, 50 Hz, 380/440 volts AC supply fitted with the following. Supply and delivery at site brand new any Board approved make floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 440 volts AC supply fitted with the following: 100 Amps MCCB with current setting range of suitable Amps of any other Board approved make of 36kA breaking capacity with U/V release, shunt release and suitable thermal release with communication port-1 Nos 1 No. Micro processor based Earth leakage relay with resin cast CBCT of Proke's dv's /or any Board approved make. Phase indicating lamps with switches of any Board approved make- 1 sets Panel mounting version digital Micro processor based type Multi function meter for measuring current, Voltage, P.F, energy etc., of any Board approved make or equivalent.- 1 Nos. MS air insulated bus bar chamber with 4 Nos.100 Amps 25 MVA Air insulated bus bar made of high conductivity, high strength aluminium alloy complying with the requirements of grade E91 E of IS 5082, suitably braced with non-hygroscopic SMS supports. Provision shall be made in the bus bar chamber for 1 incoming and 5 outgoing feeders. The bus bar chamber should be of adequate capacity to handle the incoming and out-going cables and for fixing the switchgears as per requirement-1 No. Micro processor based U/V/O/V relay with negative phase sequence protection of Proke's dv's /or any other Board approved make or equivalent- 1 Nos. Muiltifunction meter make- 1 No. 32 Amps TP load break heavy duty switch fuse with suitable capacity HRC fuses in sheet metal enclosure conforming to the latest ISS 4064 for capacitor circuit of any other Board approved make. - 4Nos.(2for capacitor+2spare) 32 Amps DP load break heavy duty switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for lighting circuit of any Board approved make. 1 No. Set of cable entries and terminals suitable for numbers, type and size of aluminium conductor power cables, etc. NOTE: 1) The panel board shall be complete with all other required fittings, and shall be fabricated using 2mm thick sheet steel and wiring shall be done using suitable size copper cable/copper wire painted with two coats of a highly corrosion resistant primer applied wet on wet and a finishing coat of synthetic enamel paint of the ash greay shade. 2) H.R.C. fuses links suitable for motor duty shall be provided to suitable Amps change over switch fuse unit. 3) H.R.C. fuse link rated not less than 1.5 times the rated current of the capacitor bank shall be provided in the suitable Amps capacity switch fuse unit for capacitor circuit. 4) The internal wiring shall be done using adequate size insulated electro tinned copper strip or cable of 1.1 KV grade. 5) Any discrepancies are noticed apart from tender specification, suitable action as per tender condition will be taken against the tenderer including black listing of the tenderer. 6) The Bus bar chamber should be of adequate size to accommodate all incoming, outgoing cables and required switchgears with all lead and lift as directed by the engineer in charge

1

-

88000

... More
Digital Soft Starter: Supply, delivery and commissioning at site brand new board approved make or equivalent floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 400/440 volts AC supply fitted with the following: 63 amps MCCB with fixed and moving contracts fitted with U/V release, shunt release and with suitable thermal release.- 1 Nos . Multi parameter such as current, kwhr, Voltage, KVA reading digital meter of prok devices or any other Board approved make - 1 Nos. Phase indicating lamps with switches of L&T/ BCH/ GE make or any other make approved by the Board - 1 set The soft starter shall have adjustable torque control facilitty to start the sewage pumpsets by reducing the starting current less than 1.5 to 2 times the full load current. It shall have bulit in facilities such as SPP, Over Voltage, Under voltage, Kick start for pump jam conditions , overload, overcurrent etc., for protection of the pumpsets. The starting current shall be controlled by three phase thyristors. The starter shall be provided with minimum 55 Amps or suitable capacity by pass contactor The panel shall be provided with cooling fan, louvers with fine mesh to facilitate the cooling of thyristors/ soft starter. The panel should be adequate size to accomadate all incoming, outgoing cable and required switchgear and other accessories with all lead and lift as directed by the engineer in charge

2

-

236000

... More
11 KV HT XLPE CABLE:Supply and laying of 3 x 120 sqmm aluminium XLPE HT cable earthed for the purpose of connecting from metering cubical to pole structure and from there to500 KVA transformer of any Board approved make with all lead and lift as directed by the engineer in charge

70

-

42799.4

... More
Main side cable: Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 with all lead and lift as directed by the engineer in charge 3.5 core 70 sqmm

60

-

21000

... More
Load side cable: Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 (To be laid in 2 runs) with all lead and lift as directed by the engineer in charge 3 core 35 sqmm

50

-

11250

... More
Capacitor Cable: Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 with all lead and lift as directed by the engineer in charge 3 core 10 sqmm

25

-

3250

... More
Transformer: Supply, erection, testing and commissioning of 11KV / 433V 3Phase 50Cys 100KVA distribution transformer with oil of load tap changer (5 star rated). a) Dehydrating breather b) Oil conservator c) Drain plug for conservator d) Off circuit tap changer in steps of +2.5% from -7.5% to +7.5 % for high voltage compensation for Transformers upto 100 KVA and -10% to +5% for Transformers 160 KVA & above. e) Thermometer pack with the thermometer f) Base channel - 2 Nos g) Lifting lugs - 2 nos h) Flat rollers i) Connecting pipe j) Oil guage - 1 Nos k) Filter valve n) Filter cum drain valve o) Winding temperature indication p) Residual oil drain plug - 1 No q) Explosion vent r) Radiator s) Bushing for high voltage side t) Cable box for low voltage side. u) Earthing terminal - 2 Nos Losses of Transformer: a) No load loss at normal volts & frequency. 670 Watts b) Load loss at full load 2840 Watts The transformer shall be fitted with all other standard fittings and painted with high grey paint to shade No. 631 of ISS and shall be supplied with first filling of transformer oil etc., complete with all lead and lift as directed by the engineer in charge (test certificate shall be furnished)

1

-

157382.45

... More
Supply and preparing 2 pole structure using 9.0 Mtr long PSCC pole wherever required as per CESC rules and specification including trasportation from factory to work spot,loading unloading, head load to site, earth work excavation by digging of pit to 1.8 mtrs depth aligning it,refilling the soil, ramming etc. complete including providing CC 1:4:8 base concrete to pole of 500 x 650 x 150 mm thick and providing concrete alround the pole of 650 x 500 x 1700 mm thick using all materials like cement, sand , jelly etc., and curing etc complete, Providing CC 1:2:4 for coping of 150mm around poles for a height of 300mm using all required materials etc., complete including (RCC poles for require , etc., complete , including 11KV disc insulators, Angles, frames, nuts and bolts.11 kv Special & Horizantal cross arms, guy sets, Spiral earth electrodes, Caution Board, pipe type Earthing, Anti climbing Device, concreting for Guy Sets,200 amps GOS with H- frame,DOLO Cut Out etc., complete as per KPTCL rules and specifications including all materials with all lead and lift as directed by the engineer in charge

1

-

42326

... More
Supply , delivery and fixing of at site 11 KV, 5KN Composite/Polymeric Pin Insulator (24mm dia FP Rod) with all lead and lift as directed by the engineer in charge

3

-

540

... More
Supply , delivery and fixing of at site 11kV, 45kN Polymeric Insulator with all lead and lift as directed by the engineer in charge

3

-

492

... More
Supply, delivery and fixing of at site LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) with all lead and lift as directed by the engineer in charge

1

-

18271.45

... More
Supply, delivery and fixing of at site LT Metering Box for housing the ETV Meters without CT's busbar wiring etc with all lead and lift as directed by the engineer in charge

1

-

4484.7

... More
Supply, delivery and fixing of at site GSM modem with connecting cable for remote communicating capabilities with all lead and lift as directed by the engineer in charge

1

-

14057

... More
Supply, delivery and fixing of at site LT Electronic Tri - Vector Meter 5A, Class-0.5 accuracy with all lead and lift as directed by the engineer in charge

1

-

3067.3

... More
Group Operated Switch: Supply , delivery and fixing of at site brand new indegenous make 200 Amps, Single break, triple pole horizontal type suitable for outdoor installation air break gang operated on/ off load insulator with two insulator stack per phase vertically isolating with copper reinforcement with MS angle suitable for operation on three phase 50 Hz 11000 Volts AC Supply conforming to ISS 1818/1972 or its latest amendments along with GI operating pole provided with isolated handle and earthing terminals etc., complete. with all lead and lift as per KPTCL specifications etc., complete.As CESC specification etc,complete with all lead and lift as directed by the engineer in charge

1

-

8814

... More
H.G. fuses: Supply and delivery at site brand new best indegeneous make horizontal mounting suitable for outdoor installation 11 KV, 3 phase, 50 c/s 400 amps 250 MVA capacity high voltage horn gap fuse units with suitable capacity fuse along with operating hickery rod for operations of fuses from ground etc., complete with all the standard fittings Set of 3 Nos. 7 741 5187 with all lead and lift as directed by the engineer in charge

1

-

4097

... More
Lightening Arrestor: Supply and delivery at site brand new best indegeneous make 11KV, 9 KA or suitable valve type lightening arrestors conforming to ISS 3070 with all the standard fittings etc., complete with all lead and lift as directed by the engineer in charge

3

-

4239

... More
Cable End Seals: Supply and fixing of 1.1 KVA Indoor and Outdoor type RAYCHEM/M-Seal make or any other make approved by the board heat shrinkable cable end seals with all required materials including copper lugs and terminals, etc.,complete with all lead and lift as directed by the engineer in charge Suitable for I) 3 x 95 sqmm. 11 KV XLPE cable, earthed, outdoor type

4

-

19056.32

... More
ii) 3 x 95 sqmm. 11 KV XLPE cable, earthed, Indoor type

2

-

9043.42

... More
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter with all lead and lift as directed by the engineer in charge

1

-

8652

... More
Erection of pumpsets: Erection of Centrifugal pumpsets on the existing main girder including formation of machine foundation using suitable size MS channels, cross girders, plate girders, bolts & nuts, washers etc., complete. Lowering of bowl assembly, column pipe pipe assembly into the jackwell and fixing of discharge head in position true to line, maintaining the VHS motor vertical alignment, dynamic balancing and linkiong to delivery line using delivery pipes from jackwell. Proper packing of the holes in the walls of jackwell after laying pipe with cement concrete 1:1.5:3 etc., complete with all lead and lift as directed by the engineer in charge

2

-

26000

... More
Laying of main side cable in new trenches: The work shall include digging of trench 0.5 wide 0.6mtrs deep providing, murrum bedding laying the cable in trench, providing cable covering tiles, refilling, consolidation, providing cable route indicating CC rocks of size 15 cms x 6 x 6cms, at the appropriate locations etc., complete with all lead and lift as directed by the engineer in charge a) 3.5 x 95 sqmm 11 KV XLPE cable

50

-

8850

... More
b) 3.5 x 70 sqmm Main side cable

30

-

5310

... More
In GI pipes: The work shall include running the cable above ground using 2.9mm thick suitable dia GI pipe with necessary clamps, bolts, nuts, washers for fixing the pipe on the pole and drainage crossings etc., complete with all lead and lift as directed by the engineer in charge a) 3 x 95 sqmm 11 KV XLPE cable

20

-

6260

... More
b) 3.5 x 70 sqmm Main side cable

10

-

3130

... More
Laying of load side cable: Running the cable in existing ducts including properly securing cable in position etc., complete using all the required materials etc., complete with all lead and lift as directed by the engineer in charge i) 3.5 Core 35 Sqmm (load side cable)

30

-

1140

... More
Laying of capacitor cable: Running the cable in existing ducts including properly securing cable in position etc., complete using all the required materials etc., complete with all lead and lift as directed by the engineer in charge 'i) 3 Core 10 Sqmm (capacitor side cable)

20

-

760

... More
Supply and fixing of perforated Cable GI Cable Tray with all lead and lift as directed by the engineer in charge 300x50mm

25

-

5300

... More
Cable Terminations: Termination of Cable using copper lungs to the terminal end for solderless crimping to aluninium conductors by using Crimping tool with all lead and lift as directed by the engineer in charge 70 sqmm 1100 volts class cable main side

2

-

190

... More
-do- 35 Sqmm 1100 volts Class cable load side

4

-

128

... More
-do- 10 Sqmm 1100 volts Class cable (capacitor)

4

-

32

... More
Power Shunt Capacitor: Supply and delivery at site brand new make approved by Board low loss high efficient of 2 banks of each 15 KVAR power shunt capacitors conforming to IS 2834/suitable for operation on 3 ph 50 Hz 380/440 volts AC supply required formaintaining the power factor of the installation at lnot less than 0.95 lagging with all lead and lift as directed by the engineer in charge a) the capacitor shall be provided with a suitable discharge device to reduce the voltage between the terminals to allowable level within one minute. b) Terminal covers on all the units and bank shall be provided.

30

-

12000

... More
Tool Kit: Supply and delivery at site best Taparia/pr any other Board approved make and other reputed make tool sets for operation and maintenance of the above pumpsets comprising of the following with all lead and lift as directed by the engineer in charge a) Double end spanner 1/4" to 1" 1 set b) Screw driver insulated 11" - 1 No c) Screw driver insulated 8" - 1 No d) Cutting puller insulated 8" - 1 No e) Hammer with handle 1 Kg - 1 No f) Pipe wrench 24" 1 No g) Pipe wrench 18" 1 No h) Pipe wrench 12" 1 No i) Hammer with handle 5Kgs 1 No j) Grease gun - 1 No k) Ring spanners 1/4" to 1" - 1 set l) Tongue tester-1No m) Multimeter-1No. n) Megger-500v of MECO or any other approved make-1No.

1

-

9316.95

... More
Earthing: Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts with all lead and lift as directed by the engineer in charge

8

-

33200

... More
Servicing and commissioning: The pumpsets (40HP) along with all other elecrical equipments shall be serviced and commissioned in the presence of the Engineer-in-charge of work including trial running for a period of 180 days. The work shall include the following. Calibration of switch gears relays and meters giving performance tests of all electrical equipments with all lead and lift as directed by the engineer in charge Giving performance tests of the pumps such as discharge, effency and the power absorbtion etc. Providing operating and maintenance manuals of the pumps and allied equipments to the operating personnel. Giving trail run of the pumpsets for a period of 90 days from the date of successful commissioning. The contractor should employ personnel to operate & maintain the pumpset and accessories during the trial run period and should train the Board/Municiple Staff to operate the pumpsets. "NOTE: 1. The energy and water will be provided by the Board free of cost. 2. The pumpsets along with all the electrical equipments shall be commissioned only when the performance of switch gears, relays are wittnessed by the Executive Engineer"

1

-

62500

... More
FIRE FIGHTING EQUIPMENTS : a) Supply and installation of CO2 type fire extinguisher 2 Kg capacity with initial charge with wall mounting bracket, ready for use (TS 2678) - 2 Nos. b) Supplying and fixing of first aid box comprising of the standard medicines to be provided in the first aid box to give first aid treatment - 1 No. c) Providing shock treatment chart on wall with inside plastic sheet cover and ply wood backplate frame work complete. d) Supply one set of fire buckets (4 Nos) with round bottom made of GI sheets 24 SWG 9 ltrs. capacity painted inside white and outside red with a word `fire' on the face of the bucket along with stand to hang the buckets. e) Supplying rubber mats tested to 22KV with ISI mark grooved, of size 6'x3'x1/2" - 2 Nos. f) Supplying rubber gloves, electrical quality, tested to 22KV - 1 Pair g) Supplying and fixing of Danger/No Admission/No Smoking Board made out of MS sheet metal with two coats of non-corrosive enamelled paint with all lead and lift as directed by the engineer in charge

1

-

15359

... More
Erection of Starter on CC foundation including formation of CC foundation using all the required materials such as cement, jelly etc., complete using required materials such as MS channel bolts, nuts, washers etc., complete with all lead and lift as directed by the engineer in charge

1

-

4375

... More
Erection of Capacitor Bank on CC foundation including formation of CC foundation using all the required materils such as cement, jelly etc., complete with all lead and lift as directed by the engineer in charge

1

-

1250

... More
Erection of control panel board on CC foundation including formation of CC foundation in CC 1:2:4 prop. using all the required materials such as cement, jelly etc., complete including errection of the panel board, on CC foundation using reqired materials with all lead and lift as directed by the engineer in charge

1

-

6250

... More
Providing and fixing of Kirloskar make vaccum pumpset along with base frame, suitable size control valve, GI pipes with specials, power cable, control panel starter suitable for 3Ph, 415 V 50Hz AC supply required for 2 Nos of 40HP centrifugal pumpsets & 2 Nos 20 HP centrifugal pumpsets with all lead and lift as directed by the engineer in charge Vacuum: 0 to 600 in MM of mercury Air flow rate: 55 to 5.0 Cum/Hour Pump size (suc x Del): 32x32 mm Rated speed: 2700 RPM Pump rating: 2.2 KW/ 3.0 HP Supply: 3Ph, 415V, 50 Hz AC

1

-

150000

... More
Supply, erection, electrification and commissioning of 2 nos. Of 30 HP or suitable HP centrifugal pumpsets with all allied accessories to pump pure water from 1.50 LL capacity GLSR near KSTDC to proposed 7.50LL capacity GLSR near Sudarshan circle Pumps: Supply and delivery at site brand new, best efficient IS/BIS/CPRI approved make horizontal split case centrifugal pump confirming to the latest ISS 1520 and IS5120 & the following description. a) Duty Condition: Capable of delivering 18.13 lps of treated/turbid water containing turbidity up to 1000/ 100000 ppm against a total head of 67.00mtrs b) Speed: Duty condition should be met at 1450 RPM. c) Shutt off head: Min 110 % & Max 130 % of the specified head. d) Material of construction: 1) Casing- Cast Iron 2) Impellor - CF 8M 3) Shaft- Stainless steel shaft- SS 410 4) Stuffing Box- Graphite Asbestos packing 5) Wear Rings- Phosphor Bronze 6) Gland- Cast Iron 7) Inter Stage Ring- Phosphor Bronze 8) Shaft Sleeve & Nuts- SS 410 9) Neck ring- SS 410 e) Driving end bearing: Grease lubricated roller/ball/ journal bearing f) Non driving end bearing: Grease lubricated deep groove ball bearing as well as journal bearing or deep groove ball bearing only. g) Coupling: Suitable size vibration proof flexible coupling with coupling guard, as recommended by the manufacturer of pump, for coupling to motor. h) Base plate: Heavy duty common CI/MS base plate for pump and motor wth suitable `I' section girders, channels, plates, bolts & nuts etc. NOTE: (1) The duty condition of the pump should be at BEP or to the left of the BEP. (2) The pump is required to work at an altitude of 800m. above MSL and at a max. ambient temperature of 45 degree C. (3) The Board reserves the right to select any stipulated make of pump. (4) The loading for low efficient pump wll be done based on the excess power consumed by it over a period of 15 years, when compared to the best efficient pump with all lead and lift as directed by the engineer in charge

2

-

455401.78

... More
Induction Motor: Minimum 30HP or suitable HP Make approved by the Board Horizontal mounted TEFC, squirrel cage induction motor, 1500 RPM motor for continuous duty conforming to IEC60034 for operation on 3 ph, 50 Hz. 430 volts. a) Protection: IP 55 b) Insulation: `F' class e) Ambient temperature: Upto 45 Degree C d) Cushion: 20 % more than maximum power required by the pump and capable of providing rated output upto + or - 10% voltage variation and/or + or - 3% frequency variation or combination of Both. e) Driving end bearing: Grease lubricated roller bearing f) Non driving end bearing: Grease lubrcated ball bearing with all lead and lift as directed by the engineer in charge

2

-

257464.28

... More
Supply. Laying, jointing, testing & commissioning of GI pipes conferming to IS 1239/1990 with latest ammendments including fixing collars, elbows, tees, bends and other fittings (excluding cost of specials) with cuts & threads wherever necessary including conveying the materials to work spot including testing for water tightness with all lead and lift as directed by the engineer in charge (Heavy Duty). 100 mm dia.

50

-

49516

... More
supply and delivery of Approximate 80 x 100 mm or suitable size flanged concentric reducers (GI) with all lead and lift as directed by the engineer in charge

2

-

1600

... More
supply and delivery of Approximate 100 or suitable size 90 deg bend (GI) with all lead and lift as directed by the engineer in charge

5

-

3750

... More
supply and delivery of Approximate 100 mm x150 mm dia MS Flanged reducer with all lead and lift as directed by the engineer in charge

1

-

1200

... More
supply and delivery of Approximate 100 mm x 100 mm radial T with all lead and lift as directed by the engineer in charge

2

-

1400

... More
Supply, & delivery of resilient sealed soft sealing sluice valves with body, bonnet of ductile iron of Grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of Vacuum tight and 100% leak proff with face dimensions as per BS 5163-89/ IS 14846-2000/ DIN3202 F4\f5 . The stem Sealing should be with Torodial sealing rings ( Minimum 2 O-rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The Valves shall be supplied with suitable size galvanised bolts and nuts of requied numbers of GKW/ KITO/NLXO/TECHMAN any other equivalent international approved brand with all lead and lift as directed by the engineer in charge -do- 100mm dia PN 16

2

-

21740.08

... More
-do- 80 mm dia for pressure relief valve

1

-

8582.12

... More
Ductile Iron check valves: Supply and fixing of ductile iron double flanged swing check vav with slanted seat or with lever weight with straight disc, wi metallic corrosion proof and wear resistant seat faces with nick overlay micro - finished/ Integral seat with body and disc in Duct Iron in GGG 40/50 shaft of stainless steel and bearings of zinc fr bronze and surface protection with epoxy liquid of GSK quality with all lead and lift as directed by the engineer in charge 100mm dia PN 16

2

-

26752.08

... More
PRESSURE RELIEF VALVES : Supply, delivery and erection of site brand new DOROT ( S-100) /BERMAD/ ERHARD make pressure relief valve of 80mm dia with maximum permisable pressure 10 Kg/cm2 with the following specifications with all lead and lift as directed by the engineer in charge 1. Valve should have direct sealing diaphragm activated by line pressure and controlled by 2 way diaphragm operated adjustable pilot valve. 2. Valve should be installed on a Tee junction, which should modulates automatically to maintain present inlet pressure and releive the excess pressure out of the network. MATERIAL OF CONSTRUCTION : 1. Body and Bonnet - Ductile Iron ISO 1083 Grade 450-10. 2. Diaphragm - Natural rubber (standard). 3. Spring - SS 302. 4. Pilot valve - Brass ISO 426. 5. Coating - Electrically applied over baked polyster. 6. End connection - Flanges BS or IS. The outlet of pressure sustaining valve should be connected to sump using MS pipes and fittings.

1

-

99540

... More
Pressure Gauge: Supply & delivery at site Airmaster/Gurusons/Forbes Marshall/WIKA make glycerene filled stainless steel pressure gauge of 150mm dia suitable for the above pumpsets with nipple, stop cock & two way cock for cleaning & necessary length of copper tubing suitable for mounting on the delivery side of pump with all lead and lift as directed by the engineer in charge

2

-

4000

... More
Combined Control panel Board Supply and delivery at site brand Sunshine /Essen/Adarsh make, floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 380/440 volts AC supply fitted with the following with all lead and lift as directed by the engineer in charge 63 Amps MCCB with current setting range of 25-32 Amps of any other Board approved make of 25kA breaking capacity with U/V release, shunt release and suitable thermal release-2Nos. Panel mounting version digital type Multifunction meter meter with built in selector switch of any Board approved make- 1 Nos. MS air insulated bus bar chamber with 4 Nos.63 Amps 25 MVA Air insulated bus bar made of high conductivity, high strength aluminium alloy complying with the requirements of grade E91 E of IS 5082, suitably braced with non-hygroscopic SMS supports. Provision shall be made in the bus bar chamber for 1 incoming and 3outgoing feeders. The bus bar chamber should be of adequate capacity to handle the incoming and out-going cables and for fixing the switchgears as per requirement-1 No. Phase indicating lamps with switches of any Board approved make- 3 sets 1No. Numerical based Earth leakage relay with resin cast CBCT of Proke's dv's /or any Board approved make. Heavy duty triple pole change over fuse switch of 63 Amps, comprising of two switches mounted on common chasis, complete with handle assembly door interlock and pad locking arrangement with mechanical linkage shorting links and 63 Amps, HRC fuses in sheet metal enclosure of board approved make conforming to the latest IS 4064 Controls and switchegear make - 1No 32 Amps DP load break heavy duty switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for lighting circuit of any Board approved make. 1 No. 33 Amps TP load break heavy duty switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for lighting circuit of any Board approved make. 2 No. Star Delta starter:Supply and delivery at site push button operated fully automatic air break contractor front operated fully automic air break contractor front operated star delta starter with thermal overload relay and delay timer in steel housing of make approved by the board along with suitable capacity air break contactor with HRC fuse for make and break capacity type single phase preventor motor "on" indicating lamp etc complete - 2 No. (30 HP) NOTE: 1) The panel board shall be complete with all other required fittings, and shall be fabricated using 2mm thick sheet steel and suitable size copper cable/copper wire painted with two coats of a highly corrosion resistant primer applied wet on wet and a finishing coat of synthetic enamel paint of the ash grey shade. 2) H.R.C. fuses links suitable for motor duty shall be provided to 32 Amps change over switch fuse unit. 3) H.R.C. fuse link rated not less than 1.5 times the rated current of the capacitor bank shall be provided in the 250 Amps capacity switch fuse unit for capacitor circuit. 4) The internal wiring shall be done using adequate size insulated electro tinned copper strip or cable of 1.1 KV grade. 5) Manufacturer test certificate is to be furnished to EE before dispacthing the materials to the work site with all lead and lift as directed by the engineer in charge

1

-

125000

... More
Power Shunt Capacitor: Supply and delivery at site brand new make approved by Board low loss high efficient of 2 banks of each 15 KVAR power shunt capacitors conforming to IS 2834/suitable for operation on 3 ph 50 Hz 380/440 volts AC supply required formaintaining the power factor of the installation at lnot less than 0.95 lagging with all lead and lift as directed by the engineer in charge a) the capacitor shall be provided with a suitable discharge device to reduce the voltage between the terminals to allowable level within one minute. b) Terminal covers on all the units and bank shall be provided.

10

-

4000

... More
Main side cable : Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 with all lead and lift as directed by the engineer in charge 3.5 core 25 sqmm

70

-

12600

... More
Load side Cable : Supply & delivery of brand new PVC insulated copper conductor flat submersible cable 1.1 KV grade conforming to latest Indian Standard Specification with all lead and lift as directed by the engineer in charge 1x3x6 Sqmm

110

-

22550

... More
Transformer: Supply, erection, testing and commissioning of 11KV / 433V 3Phase 50Cys 100KVA distribution transformer with oil of load tap changer (5 star rated) with all lead and lift as directed by the engineer in charge a) Dehydrating breather b) Oil conservator c) Drain plug for conservator d) Off circuit tap changer in steps of +2.5% from -7.5% to +7.5 % for high voltage compensation for Transformers upto 100 KVA and -10% to +5% for Transformers 160 KVA & above. e) Thermometer pack with the thermometer f) Base channel - 2 Nos g) Lifting lugs - 2 nos h) Flat rollers i) Connecting pipe j) Oil guage - 1 Nos k) Filter valve n) Filter cum drain valve o) Winding temperature indication p) Residual oil drain plug - 1 No q) Explosion vent r) Radiator s) Bushing for high voltage side t) Cable box for low voltage side. u) Earthing terminal - 2 Nos Losses of Transformer: a) No load loss at normal volts & frequency. 670 Watts b) Load loss at full load 2840 Watts The transformer shall be fitted with all other standard fittings and painted with high grey paint to shade No. 631 of ISS and shall be supplied with first filling of transformer oil etc., complete. (test certificate shall be furnished)

1

-

157382.45

... More
Supply , delivery and fixing of at site 11 KV, 5KN Composite/Polymeric Pin Insulator (24mm dia FP Rod) with all lead and lift as directed by the engineer in charge

3

-

540

... More
Supply , delivery and fixing of at site 11kV, 45kN Polymeric Insulator with all lead and lift as directed by the engineer in charge

3

-

492

... More
Supply, delivery and fixing of at site LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) with all lead and lift as directed by the engineer in charge

1

-

18271.45

... More
Supply, delivery and fixing of at site LT Metering Box for housing the ETV Meters without CT's busbar wiring etc with all lead and lift as directed by the engineer in charge

1

-

4484.7

... More
Supply, delivery and fixing of at site GSM modem with connecting cable for remote communicating capabilities with all lead and lift as directed by the engineer in charge

1

-

14057

... More
Supply, delivery and fixing of at site LT Electronic Tri - Vector Meter 5A, Class-0.5 accuracy with all lead and lift as directed by the engineer in charge

1

-

3067

... More
Extension of LT line Supply, delivery and fixing of at site RCC Pole - 9 Mtr Long, 145 Kg WL with all lead and lift as directed by the engineer in charge

2

-

15897.4

... More
Supply, delivery and fixing of at site 4 Pin Cross Arm with pole clamp, bolt & nuts & washers for RCC Pole - MS with all lead and lift as directed by the engineer in charge

7

-

2839.9

... More
Supply, delivery and fixing of at site No.8 strain insulator with all lead and lift as directed by the engineer in charge

28

-

448

... More
Supply, delivery and fixing of at site 11kV, 5KN Composite/Polymeric Pin Insulator (24mm dia FRP Rod) with all lead and lift as directed by the engineer in charge

4

-

720

... More
Supply, delivery and fixing of at site Rabbit ACSR with all lead and lift as directed by the engineer in charge (6/3.35 mm Al + 1/3.35 mm St), Std Wt : 214 kgs/km

0.5

-

20328.52

... More
Supply, delivery and fixing of at site Guy Sets with No 15 strain insulator with all lead and lift as directed by the engineer in charge

3

-

4062.9

... More
Supply, delivery and fixing of at site Sheet Metal/Deep Drawn Street Lighting Metering Box with Automatic Control Switch, contactors with Single Phase 5-30 Amps meter & 50/5A CT with all lead and lift as directed by the engineer in charge

1

-

6860.25

... More
Supply, delivery and fixing of at site PVC Pipe with all lead and lift as directed by the engineer in charge 40 mm Dia

10

-

460

... More
Supply, delivery and fixing of at site PVC Wire with all lead and lift as directed by the engineer in charge 25 Sqmm Al Wt: 6.7 Kgs, Total Wt: 11.5Kgs for 100Mtrs

10

-

323.1

... More
Supply and preparing 2 pole structure using 9.0 Mtr long PSCC pole wherever required as per CESC rules and specification including trasportation from factory to work spot,loading unloading, head load to site, earth work excavation by digging of pit to 1.8 mtrs depth aligning it,refilling the soil, ramming etc. complete including providing CC 1:4:8 base concrete to pole of 500 x 650 x 150 mm thick and providing concrete alround the pole of 650 x 500 x 1700 mm thick using all materials like cement, sand , jelly etc., and curing etc complete, Providing CC 1:2:4 for coping of 150mm around poles for a height of 300mm using all required materials etc., complete including (RCC poles for require , etc., complete , including 11KV disc insulators, Angles, frames, nuts and bolts.11 kv Special & Horizantal cross arms, guy sets,Spiral earth electrodes,Caution Board,pipe type Earthing,Anti climbing Device,concreting for Guy Sets,200 amps GOS with H- frame,DOLO Cut Out etc., complete as per KPTCL rules and specifications including all materials with all lead and lift as directed by the engineer in charge

1

-

42326

... More
Group Operated Switch: Supply , delivery and fixing of at site brand new indegenous make 200 Amps, Single break, triple pole horizontal type suitable for outdoor installation air break gang operated on/ off load insulator with two insulator stack per phase vertically isolating with copper reinforcement with MS angle suitable for operation on three phase 50 Hz 11000 Volts AC Supply conforming to ISS 1818/1972 or its latest amendments along with GI operating pole provided with isolated handle and earthing terminals etc., complete. with all lead and lift as per KPTCL specifications etc., complete.As CESC specification etc,complete with all lead and lift as directed by the engineer in charge

1

-

8814

... More
Erection of pumpsets: Erection of Centrifugal pumpsets on the existing main girder including formation of machine foundation using suitable size MS channels, cross girders, plate girders, bolts & nuts, washers etc., complete. Lowering of bowl assembly, column pipe pipe assembly into the jackwell and fixing of discharge head in position true to line, maintaining the VHS motor vertical alignment, dynamic balancing and linkiong to delivery line using delivery pipes from jackwell. Proper packing of the holes in the walls of jackwell after laying pipe with cement concrete 1:1.5:3 etc., complete with all lead and lift as directed by the engineer in charge

2

-

18000

... More
Laying & jointing of GI pipes and specials for suction and delivery connections of the pump using suitable size bolts, nuts, packing etc., complete including fixing , all types of valves, gauges, strainers, delivery mainfold. The work shall include providing pipe supports, thrusts block in CC 1:2:4 prop., wherever necessary upto the end of the delivery mainfold, using all the requied materials such as sand cement jelly including making holes in sump pump house for laying suction and devliery pipes, packing of holes wih CC 1:2:4 etc., complete. (all lead and lift)( 2 Nos of pumpsets). The work also includes supply and laying of MS specials which are required for erection of pumpsets with all lead and lift as directed by the engineer in charge

1

-

12500

... More
Laying of main sidecable of 3 1/2 core 25 Sqm Main side cable of 1 run In new trenches : Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete with all lead and lift as directed by the engineer in charge In ordinary soil

30

-

2280

... More
Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV with all lead and lift as directed by the engineer in charge 50mm dia

10

-

3800

... More
In GI pipes : Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required with all lead and lift as directed by the engineer in charge 25 sqmm to 75 sqmm

10

-

155

... More
Laying of 3 core 4 sqmm capacitor cable : Running the cable in existing ducts including properly securing cable in position etc., complete using all the required materials etc., complete with all lead and lift as directed by the engineer in charge 6 sqmm to 16 sqmm

5

-

59.4

... More
Cable terminations : Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes with all lead and lift as directed by the engineer in charge 3 1/2 Core 25 sqmm 1100 volts class cable (main side)

6

-

120

... More
-do- 3 Core 4 sqmm 1100 volts class cable (capacitor) with all lead and lift as directed by the engineer in charge

3

-

21

... More
Supply and fixing of perforated Cable GI Cable Tray with all lead and lift as directed by the engineer in charge 300x50mm

10

-

2120

... More
EARTHING Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts with all lead and lift as directed by the engineer in charge

8

-

33200

... More
Tool Kit: Supply and delivery at site best Taparia/pr any other Board approved make and other reputed make tool sets for operation and maintenance of the above pumpsets comprising of the following with all lead and lift as directed by the engineer in charge a) Double end spanner 1/4" to 1" 1 set b) Screw driver insulated 11" - 1 No c) Screw driver insulated 8" - 1 No d) Cutting puller insulated 8" - 1 No e) Hammer with handle 1 Kg - 1 No f) Pipe wrench 24" 1 No g) Pipe wrench 18" 1 No h) Pipe wrench 12" 1 No i) Hammer with handle 5Kgs 1 No j) Grease gun - 1 No k) Ring spanners 1/4" to 1" - 1 set l) Tongue tester-1No m) Multimeter-1No. n) Megger-500v of MECO or any other approved make-1No

1

-

9316.95

... More
FIRE FIGHTING EQUIPMENTS : a) Supply and installation of CO2 type fire extinguisher 2 Kg capacity with initial charge with wall mounting bracket, ready for use (TS 2678) - 2 Nos b) Supplying and fixing of first aid box comprising of the standard medicines to be provided in the first aid box to give first aid treatment - 1 No. c) Providing shock treatment chart on wall with inside plastic sheet cover and ply wood backplate frame work complete. d) Supply one set of fire buckets (4 Nos) with round bottom made of GI sheets 24 SWG 9 ltrs. capacity painted inside white and outside red with a word `fire' on the face of the bucket along with stand to hang the buckets. e) Supplying rubber mats tested to 22KV with ISI mark grooved, of size 6'x3'x1/2" - 2 Nos. f) Supplying rubber gloves, electrical quality, tested to 22KV - 1 Pair g) Supplying and fixing of Danger/No Admission/No Smoking Board made out of MS sheet metal with two coats of non-corrosive enamelled paint with all lead and lift as directed by the engineer in charge

1

-

15359

... More
Servicing and Commissioning: The pumpsets along with all other elecrical equipments shall be serviced and commissioned in the presence of the Engineer-in-charge of work including trial running for a period of 180 days. The work shall include the following servicing and heat running of the pumpsets along with allied equipments with all lead and lift as directed by the engineer in charge Calibration of switch gears relays and meters giving performance tests of all electrical equipments. Giving performance tests of the pumps such as discharge, effency and the power absorption etc. Providing operating and maintenance manuals of the pumps and allied equipments to the operating personnel. Giving trail run of the pumpsets for a period of 90 days from the date of successful commissioning. The contractor should employ personnel to operate & maintain the pumpset and accessories during the trial run period and should train the Board/Municipal Staff to operate the pumpsets. NOTE: 1. The energy and water will be provided by the Board free of cost. 2. The pumpsets along with all the electrical equipments shall be commissioned only when the performance of switch gears, relays are witnessed by the Executive Engineer in charge of the work and Asst. Executive Engineer (Electrical) of the Board and certified regarding the performance of relays/switch gears.

2

-

12000

... More
Erection of Capacitor Bank on CC foundation including formation of CC foundation using all the required materials such as cement, jelly etc., complete with all lead and lift as directed by the engineer in charge

1

-

2000

... More
Erection of control panel board on CC foundation including formation of CC foundation in CC 1:2:4 prop using all the required materials such as cement, jelly etc., complete including erection of the panel board, on CC foundation using reuired materials such as MS channel bolts, nuts, washers etc., complete with all lead and lift as directed by the engineer in charge

1

-

3000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.