Karnataka Urban Water Supply And Drainage Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Urban Water Supply And Drainage Board - KUWSDB Tender

Opening Date23 Jul 2021
Closing Date31 Jul 2021
Tender Amount₹ 1,34,23,66,260 
This is an estimated amount, exact amount may vary.

Costs

  • EMD

    NA
  • Document Cost

    NA
  • Tender Fee

    NA

Summary

Part-a: Providing 2nd Stage Wss To Shorapur Town And 3 Enroute Villages With Krishna River As Source. Part-b: O&m Of Wss For A Period Of 5 Years.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents

No Documents Available

Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of 6.0 M dia, 9mt depth Intake Well:- Earthwork excavation for foundation of structures by Mechanical Means as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting bracing, removal of slumps and other deletrious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., with all lead and lift complete & as directed by engineer-in-charge For 0 to 3 mtr depth- In Ordinary / All soils / Hard soil- including dewatering. IC-1&2

2307.34

-

257891.39

... More
-do- For 0 to 3 mtr depth- Ordinary rock comprising of lime stone, sand stone, hard laterite, fissured rock, conglomerate or other soft or '-do- disintegrated rock which may be querried without resorting to blasting..with all lead and lift complete & as directed by engineer-in-charge-including dewatering

2160.66

-

322003.16

... More
-do-For 0 to 3 mtr depth- In hard rock, excavation by using Mechanical plant / machinery..with all lead and lift complete & as directed by engineer-in-charge-including dewatering

122.29

-

106362.95

... More
-do- For 3 to 6 mtr. Depth- In hard rock, excavation by using Mechanical plant / machinery ..with all lead and lift complete & as directed by engineer-in-charge-including dewatering

1148.24

-

1147677.36

... More
Providing and laying C.C. 1:1.5:3 proportion for foundation (Screed layer) with 20 mm and down size of approved gradation hard broken granite, trap basalt or with any other approved hard aggregate including cost and conveyance of all materials with an all lead & lifts including plywood / steel form work, machine mixing, laying, tamping, vibrating curing etc.,with all lead and lift complete & as directed by engineer-in-charge, PCC for IC-1&2,PCC Connection main pipeline,RCc Jackwell,PCC RWRM pipeline, PCC Chemical House, PCC for Flacculator, PCC pure Water sump, PH(6x9), Sludge Chamber, 10LL-oht-MT,15LL-OHT-Zone-1,15LL-OHT-Zone-2, 15LL-OHT-Zone-3,10LL-OHT-Zone-4,15LL-OHT-Zone-5,15LL-OHT-Zone-6,15LL-OHT-Zone-7, Sump-160cum, PH-3x6,

882.07

-

5283008.31

... More
Providing and laying vibrated M 25 design mix for RCC works (excluding cost of reinforcement) with 20mm and down size of approved gradation hard broken granite, trap, basalt or with any other approved hard aggregate including weight batch mixing plant cost and conveyanced of all materials with all lead & lift laid in 15cms, thick layers, well consolidated, vibrating, curing, smooth finishing the exposed faces wherever necessary plywood/steel form work, centering etc., complete for independent/combined footing, raft, beams below ground level-(Minimum Cement at 360 Kgs)-with all lead and lift complete & as directed by engineer-in-charge. For IC-1&2.

260.94

-

1883605.83

... More
Providing and fixing 25 mm dia 2.75 m long ribbed steel anchor rods with one end split and driven firmly using steel wedge into 1.25 m deep 38 mm dia. hole drilled in bed rock and other end provided with L-bend for embedding in concrete / masonry for spillway and appurtenant works including cost of all materials, machinery, labour, steel wedge, drilling and cleaning hole, filling hole with thick cement slurry, driving anchor rod etc., complete with lead upto 1 km and all lifts-with all lead and lift complete & as directed by engineer-in-charge. For IC-1&2.RCC Jackwell

163

-

167727

... More
Providing and laying vibrated M30 design mix for RCC works (excluding cost of reinforcement) with 20 mm and down size of approved gradation hard broken granite, trap, basalt or with any other approved hard aggregate including cost and conveyance of all materails with all lead and lift, plywood/steel form work, centering, scaffolding, plastering and smooth finishing the exposed faces in CM. 1:3 12mm thick and CM plastering 1:3 proportion 20mm thick for inside with an admixture of water proof compound of requisite proportion of approved quality including weigh batch plant mixing, curing etc., and reservoir given satisfactory water proof testing as per directions, etc., complete, for vertical side walls, alround effluent channel baffles etc. (contractor will make his own arrangements for procuring water for testing) (minimum Cement @ 400Kgs) -with all lead and lift complete & as directed by engineer-in-charge.For IC-1&2

117.27

-

1671077.56

... More
Providing and laying vibrated cement concrete M 30 design mix for RCC works (excluding cost of reinforcement) with 20mm and down size of approved gradation hard broken granite, basalt, trap or any other approved hard aggregate with plastering and smooth finishing the exposed faces in C.M. 1:3 12mm thick including cost and conveyance of all materials with all lead & lift including weigh batch plant mixing centering plywood/steel form work, centering, scaffolding, curing, as per designs etc., complete for columns, braces and ring beam above ground level ( Cement at 400 kgs)- with all lead and lift complete & as directed by engineer-in-charge. For IC-1&2,for RCC Jackwell,For Vertical steining above Deck level, wall, Landing Platforms inside JW, For ring beam at deck level, lintel level,Partition wall of pumphouse, side wall of pumphouse above lintel level, For corbel beam,Corbel Gantry Kerb,Roof beam,Roof beam inverted, Columns for PH,For Cantilever beam at Deck Level, For Cantilever Slab at Deck Level, For Cantilever beam at Lintel Level.For Approach bridge,for Longitudinal Bracing,Abutment & wing wall,For Roof level Beam TBB - 1- for transformer yard, Panel room, Roof level Beam TBB - 2 for transformer yard,Panel room, For Roof Slab,Transformer yard , For Chemical house- Columns, GF,FF Slab, Chemical house-For Ground Floor & first roof slab, staircase, tank wall and tank of 4.3 x 2.66, Platform, For Clarifier, Flocculator Tank,Sludge outlet Chamber, slab, For 8LL-Sump-raft, Side Wall, Haunch, For Top ring beam outer, inner ring beam, Finial ring beam, slab, top dome, For chemical house-For Beam, Roof level beams,slab, For 1.6LL Sump-. For main and secondary beams below & above floor level, Top ring beam, Finial ring beam, topdome, walkway, side wall, haunch, For PH-3x6- For columns above GL upto Gantry girder,Columns above GL & above Gantry girder, lintel roof beams,

1097.21

-

14209001.17

... More
Providing and laying vibrated cement concrete M 30 design mix for RCC works (excluding cost of reinforcement) with 20mm and down size of approved gradation hard broken granite, basalt, trap or any other approved hard aggregate including cost and conveyance of all materials with all lead & lift above staging including weigh batch plant mixing centering plywood/steel form work, scaffolding tamping, curing, cement mortar plastering in CM 1:3 proportion 12mm thick for inside surface and outside surface etc,comple for RCC flat slab with plastering in CM 1:3 (Cement at 400 kgs) with all lead and lift complete & as directed by engineer-in-charge

11.57

-

200148.27

... More
Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) including for OHT & reservoier, cost of materials, labour, HOM of machinery complete as per specifications. TMT bars Fe 500-with all lead and lift complete & as directed by engineer-in-charge, For IC-1&2,For RCC Connecting main, RCC Jackwell,RCC Approach bridge, MS-RWRM,RCC-VC,Chemical house,Clarifier,8LL Sump,MS-PWRM,DI-PWGM, 10LL-OHT-MT,15LL-OHT-Zone-1,15LL-OHT-Zone-2, 15LL-OHT-Zone-3, 10LL-OHT-Zone-4,15LL-OHT-Zone-5,15LL-OHT-Zone-6, 15LL-OHT-Zone-7.PH-6x3, PWGM,Distribution

1236.38

-

64332857.27

... More
Refilling pipeline trenches and foundation with selected available earth from trench excavation and foundation including watering, consolidation in layers of 15 cms., thickness with Vibro Rollers including disposing off the surplus earth with all lead and lift-with all lead and lift complete & as directed by engineer-in-charge. Cofferdam, RCC intake well, IC-1&2, RCC connecting main, RCC Jackwell, RWRM, PWRM,RCC Approach bridge, MS-RWRM,RCC-VC,Chemical house,Clarifier,8LL Sump,MS-PWRM,DI-PWGM, 10LL-OHT-MT,15LL-OHT-Zone-1,15LL-OHT-Zone-2, 15LL-OHT-Zone-3, 10LL-OHT-Zone-4,15LL-OHT-Zone-5,15LL-OHT-Zone-6, 15LL-OHT-Zone-7.PH-6x3, PWGM,Distribution.

77569.12

-

8553546.86

... More
Supplying & Fixing CI puddle flanges Conforming ti IS 7181-1986 with latest amendments, in position for R.C.C. walls including hoisting and conveying them to work spot with all lead and lift etc.,with all lead and lift complete & as directed by engineer-in-charge-1000mm dia CI Puddle flange. For IC-1&2, RCC Jackwell

12

-

1320000

... More
Supplying, laying of CI puddle flange Entry pipe true to line / hoisting of CI flanged pipe conforming to IS 7181-1986 with latest comendments in position and aligning to correct plumb including cost of jointing material, conveying to work spot with all lead and lifts etc with Screening arrangement-with all lead and lift complete & as directed by engineer-in-charge-1600mm dia CI Puddle flange Entry pipe with rose piece screening arrangement

4

-

1000000

... More
Earthwork excavation for foundation of structures by Mechanical Means as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting bracing, removal of slumps and other deletrious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., with all lead and lift complete & as directed by engineer-in-charge For 3 to 6 mtr depth- In Ordinary rock, soft rock and medium hard laterite comprising of Lime stone, sand tone hard shale, schiest, fissured rock without resorting to blasting-with all lead and lift complete & as directed by engineer-in-charge - including de-watering

247.92

-

42362.09

... More
-do- For 6 to 9 mtr depth- In hard rock, excavation by using Mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge -including de-watering

1495.5

-

1717641.57

... More
Earth work excavatoin for pipe line trenches beyond 600mm Trenches width as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc.,. with all lead and lift complete & as directed by engineer-in-charge - by Mechanical Means- For 0 to 3.0 mtr depth- In ordinary/ All soils/Hard soil - including de-watering.

1766.12

-

294959.7

... More
-do- For 0 to 3.0 mtr depth- Ordinary rock comprising of lime stone, sand stone, hard laterite, fissured rock, conglomerate or other soft or disintegarted rock which may be querried or split with crow bars. Boulders which do not require blassting having max. Dia in any direction of more than 300mm; found lying loose on the surface or embedded in river bed, soil, talus, slope wash and terrace material of dissimilar origin - with all lead and lift complete & as directed by engineer-in-charge- including de-watering

1059.67

-

236878.63

... More
-do- For 0 to 3.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge-including de-watering

706.45

-

921203.74

... More
-do- For 3.0 to 6.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge-including de-watering

2094.9

-

3551253.53

... More
-do- For 6.0 to 9.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge- including de-watering

582.59

-

1283876.89

... More
-do- For 9.0 to 12.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge - including de-watering

221.65

-

634998.44

... More
-do- For 12.0 to 15.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge- including de-watering

4.44

-

13257.22

... More
Supplying S&S RCC spun pipes NP-3 class conforming to IS 458:1988 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials (excluding cost of specials) including perfect linking of joints with jack to correct position including cost of jointing materials ie., rubber rings confirming to IS for S&S RCC pipes with all lead & lift & as directed and giving necessary hydraulic test to the required pressure as per ISS and testing & commissioning (contractor will make his own arrangements for procuring water for testing) (For UGD works the pipe shall be manufactured using Sulphate Resistant Cement (SRC) only - with all lead and lift complete & as directed by engineer-in-charge -1000mm dia RCC-NP-3 in two rows of Pipeline

360

-

2984065.2

... More
Providing and laying CC 1:2:4 proportion (excluding cost of reinforcement) with 20 mm and down size of approved gradation hard broken granite, trap basalt or with any other approved hard aggregate including cost and conveyance of all materials with an all lead & lifts and placing the same above or below ground level including plywood / steel form work, machine mixing, laying, tamping, curing etc., complete including smooth finishing the exposed faces with CM 1:4, proportion 12mm thick wherever necessary etc, with all lead and lift complete & as directed by engineer-in-charge - for Anchor Blocks and Thrust blocks

409.6

-

2643021.82

... More
Cutting of trees girth from 300mm to 600mm including cutting of trunks, branches and removal of stumps roots stacking of serviceable materials earth filling in the depressions/pit, labour charges complete as per specifications -with all lead and lift complete & as directed by engineer-in-charge -Trees cutting-300mm to 600mm. For RCC Jackwell

15

-

4801.65

... More
-do- For Trees cutting-600mm to 900mm

20

-

19741.8

... More
Clearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings ad tress of girth upto 300mm, by manual means, in area of light jungle, removal of stumps disposal of unservicieable materials, stacking of serviceable materials, labours charges - with all lead and lift complete & as directed by engineer-in-charge

82.48

-

1324.63

... More
Earthwork excavation for foundation of structures by Mechanical Means as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting bracing, removal of slumps and other deletrious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., with all lead and lift complete & as directed by engineer-in-charge'-do- For 3 to 6.0 mtr depth- Ordinary rock comprising of lime stone, sand stone, hard laterite, fissured rock, conglomerate or other soft or disintegarted rock which may be querried or split with crow bars. Boulders which do not require blassting having max. Dia in any direction of more than 300mm; found lying loose on the surface or embedded in river bed, soil, talus, slope wash and terrace material of dissimilar origin - with all lead and lift complete & as directed by engineer-in-charge-including de-watering

1046.33

-

178786.41

... More
-do- For 9.0 to 12.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge-including de-watering

1019.52

-

1345164.88

... More
-do- For 12.0 to 15.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge-including de-watering

778.42

-

1229234.16

... More
-do- For 15.0 to 18.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge-including de-watering

626.1

-

1116893.53

... More
-do- For 18.0 to 21.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery - with all lead and lift complete & as directed by engineer-in-charge-including de-watering

201.61

-

400929.71

... More
Providing casing embankment using semi-pervious soil from approved borrow areas in layers of 250 to 300 mm before compaction including cost of all materials, machinery, labour, all other operations such as excavation, sorting out, transportation, spreading soil to specified thickness, breaking clods, sectioning, watering, compacting to density control of not less than 95 percent using power roller etc., complete with all lead and lifts- with all lead and lift complete & as directed by engineer-in-charge

868.96

-

194325.52

... More
Providing and constructing 450 mm thick hand packed rough stone revetment consisting of 300 mm thick rough stones with 400 to 450 mm long through stones at 1.5 m c / c over a backing of 150 mm thick 40 mm down graded coarse aggregate layer including cost of all materials, machinery, labour, laying to specified slope, wedging with chips, finishing etc., complete with all lead and lifts with all lead and lift complete & as directed by engineer-in-charge

278.07

-

162053.63

... More
Providing and laying vibrated M 25 design mix for RCC works (excluding cost of reinforcement) with 20mm and down size of approved gradation hard broken granite, trap, basalt or with any other approved hard aggregate including weight batch mixing plant cost and conveyanced of all materials with all lead & lift laid in 15cms, thick layers, well consolidated, vibrating, curing, smooth finishing the exposed faces wherever necessary plywood/steel form work, centering etc., complete for independent/combined footing, raft, beams below ground level.(Cement at 360 Kgs) with all lead and lift complete & as directed by engineer-in-charge.Approach bridge For Columns Footings, Transformer Yard & Panel room, For Longitudinal Bracing,Abutment, wing wall & OHT's, RWRM,Chemical house-For Column Footing, Plinth beam,RCC 8LL-Sump-Raft, PH-for columns, plinth beams, For Sludge chamber-or Raft, For Side wall,Ring Beam at Top, Roof Slab, For 10LL-OHT- MT,For FOOTING RECTANGULAR PORTION,FOOTING TRAPEZOIDAL PORTION, RAFT RING BEAM (Balance portion),RING BEAM, For 15LL-OHT-Z-1, For 15LL-OHT-Z-2, For 15LL-OHT-Z-3, For 10LL-OHT-Z-4, For 15LL-OHT-Z-5,For 15LL-OHT-Z-6,For 15LL-OHT-Z-7, For 1.6LL Sump, for PH-6x3

4459.34

-

33135215.06

... More
Providing and laying vibrated M30 design mix for RCC works (excluding cost of reinforcement) with 20 mm and down size of approved gradation hard broken granite, trap, basalt or with any other approved hard aggregate including cost and conveyance of all materails with all lead and lift, plywood/steel form work, centering, scaffolding, plastering and smooth finishing the exposed faces in CM. 1:3 12mm thick and CM plastering 1:3 proportion 20mm thick for inside with an admixture of water proof compound of requisite proportion of approved quality including weigh batch plant mixing, curing etc., and reservoir given satisfactory water proof testing as per directions, etc., complete, for for RCC steinning below ground level, (contractor will make his own arrangements for procuring water for testing) (minimum Cement @ 400Kgs) with all lead and lift complete & as directed by engineer-in-charge For Vertical steining wall below GL -1 of JW- 1m width

197.95

-

2105718.86

... More
-do- For Vertical steining wall below GL -1 of JW -0.70m width - with all lead and lift complete & as directed by engineer-in-charge

302.53

-

3218202.2

... More
-do- For Vertical steining wall above GL -1 of JW -0.50m width - with all lead and lift complete & as directed by engineer-in-charge

153.41

-

1647028.17

... More
-do- For Platforms for steining walls -with all lead and lift complete & as directed by engineer-in-charge

2.16

-

23190.02

... More
Providing and laying vibrated cement concrete M 30 design mix for RCC works (excluding cost of reinforcement) with 20mm and down size of approved gradation hard broken granite, basalt, trap or any other approved hard aggregate including cost and conveyance of all materials with all lead & lift above staging including weigh batch plant mixing centering plywood/steel form work, scaffolding tamping, curing, cement mortar plastering in CM 1:3 proportion 12mm thick for inside surface and outside surface etc,comple for Topflat slab (Cement at 400 kgs) with all lead and lift complete & as directed by engineer-in-charge, For roof slab Top dome of pump house.

10.47

-

222066.61

... More
Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24 kgs, with 12mm and down size graded granite metal coarse aggregates @ 0.5175cum and fine aggregates @ 0.0345cum, with superplastisiser @0.225lts, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete but excluding cost of reinforcement with all lead and lift complete & as directed by engineer-in-charge. For Over R/S,Over Window, Pump House,

36.56

-

17420.47

... More
Providing and fixing pull and push type rolling shutters of approved make out of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations complete including pulling hooks, 4Nos. handles with all fittings and acessories, painted with a coat of red lead paint (without top cover) cost of materials, labour, HOM of machinery complete as per specifications. Shutter size 3.00x2.80m with all lead and lift complete & as directed by engineer-in-charge. For RCC Jackwell, Filter Shed, PH

21.9

-

61124

... More
Providing and fixing top covers made out of 20 guage M.S.sheet over pull and push rolling shutters bent to shape including cost of red lead primer coat of painting, materials, labour, HOM of machinery with all lead and lift complete & as directed by engineer-in-charge.

6.8

-

3509

... More
Providing and fixing in position in cement concrete 1:3:6 steel glazed windows and ventilatos side hung/top hung fully openable as per approved drawings using Z angles of 25x33x3mm. weighing 1.419 Kg/m both for outer and inner frames and central mullion section of size 25x46x3mm. weighing 2.28Kg/m duly providing T section 19x19x3mm weighing 0.839 Kg/m for glazing of windows not more than 34 cms. c to c including providing and fixing 4mm. thick reeded glass with teakwood beading of required size, all steel sections should confirm to I.S. 7452:1990, 4nos. of holdfasts of approved size,section should be cut to length welded and electrically grinded subdividing frames of unit shall be tenonned and revetted into the frames electrically. All the steel surface shall be throughly cleaned free of rust and painted with one coat of anti-corosive paint and finishing with two coats of ready mix paint of approved colour and make including cost of materials, fixtures, labour and HOM of machinery complete with all lead and lift complete & as directed by engineer-in-charge.

104.96

-

373968.28

... More
Supplying & fixing 40mm dia SS medium duty pipes hand railing 3 rows fixed to bottom placed at 2 Mtr intervals including curing, painting SS pipes with two coats of anticorrosive steel paint over a primer coat with all lead and lift complete & as directed by engineer-in-charge. For Jackwell alround, Hand railing for platforms for ladder for ALL OHT's, PH, Jackwell Foot Bridge etc.

1618.52

-

1578574.93

... More
Providing 2 coats of water proof cement painting of approved quility colure and shade over one coat of primer including scraping faces, with wire brushes etc,. before removal of scaffolding for new RCC Over Head Tanks and cleaning of paint stains wereever necesary with all lead and lift complete & as directed by engineer-in-charge. For J.W. Cum Pum house, Jackwell Steining,Pumphouse side wall, Columns inside pumphouse,Cantilever slab at deck level, Chajja, for PH, OHT's, Jackwell, etc

2932.82

-

580874.33

... More
Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after throughly brooming the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, with all lead and lift complete & as directed by engineer-in-charge. For Inside wall and ceiling

364.05

-

33907.62

... More
Providing and applying enamel metal paint two coats (excluding priming coat) over new steel or other metal surface brushes to give an even shade after cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, complete all lead and lift complete & as directed by engineer-in-charge. For Main Entrance Rolling shutter

27

-

2746.17

... More
Providing and fixing M.S. ladder between landing 45 cms. wide using angle iron of following sie and 20mm M.S. bars at 25cms. Centre to centre with necessary supports of same angle iron as directed including hand railing on both sides with 25mm dia G.I. pipes with angle iron props at 2 mtrs, interval and 0.5 mtr, height including fixing in ground with C.C. 1:2:4 and two coats of non-poisonous anticorrosive bituminous paint with all lead and lift etc.complete all lead and lift complete & as directed by engineer-in-charge. For Jackwell, Sump, OHT's, Pump house.

295.25

-

604456.47

... More
Supplying and fixing lightning arrestor of aluminium strip 25mm x 3mm size including final and grounding, aluminium strip is to be embeded in one of the columns in an independent G.I. Conduit of 40mm dia pipe suitably jointed by collars with all specials with all lead etc., with all lead and lift etc.complete all lead and lift complete & as directed by engineer-in-charge

1

-

10980.72

... More
Providing and fixing MS inspection door of size 60x60 cms including M.S. frame of MS angle 50x50x6 mm and MS shutter of 3.0mm thick with hinges of top and locking arrangement, painting etc, complete ith all lead and lift etc.complete all lead and lift complete & as directed by engineer-in-charge. For Jackwell, Sump's, OHT's, Pump house.

23

-

42232.14

... More
Supply and fixing of cast steel double flanged dual plate check valve confirming to API 594 with latest amendments as detailed below of following diameters and types and conveying to work site, loading, unloading, stacking etc, complete with complete all lead and lift complete & as directed by engineer-in-charge- 1000mm dia CS class 300

2

-

604319.48

... More
Supplying, fabrication and errection of Gantry crane girder 5 MT capacity with complete all lead and lift complete & as directed by engineer-in-charge (The design of Gantry girder should be get it approved from competent aurhority before execution)

1

-

1167055

... More
Supplying, fabrication and errection providing and fixing of chequered plate flooring with complete all lead and lift complete & as directed by engineer-in-charge (The design of Chequered plate flooring should be get it approved from competent aurhority before execution) - For Jackwell

1

-

1023349

... More
Providing Valve shaft Closing Arrangement for 1000 mm dia NP-3 RCC new connecting main: Providing and fixing M.S.Sluice gate 600mm Jackwell. The gate will be febricated from 12mm thick MS plate with 31 x 10 x 80mm dia musical note bype. Rubber seal bolted to the plate. The gate frame will be made from 250 x 8 M.S. Channel of size 0.80 M wide x 1.65 M height. The gate will be operated through 40mm dia CI hand wheel, and CI bush housing gun metal bush to suit 50mm dia spindle with 4 TPI square threads 800mm long. The CI bush supported on 8-12mm steel bals for easy rotation. The spindle will be bolted at the centre of the sluice gate. The hoist will be 9.5 m or suitable height and fixed on a base frame. The frame will be folted or welded to existing steel frame on the jackwell supporting pumps suitable supports will be given to the shaft complete with complete all lead and for all lifts complete & as directed by engineer-in-charge.

2

-

130000

... More
Supplying, fabricating and fixing of rods of 25mm dia or suitable dia for opening and closing arrangements at Inlet pipes of connection main with complete all lead and for all lifts complete & as directed by engineer-in-charge.

215.45

-

19605.95

... More
Providing all Electrification works to Jackwell cum pumphouse, WTP, IPS and at Mother Tank including inside and outside with street light arrangement to head works and yard lighting to WTP, Mother Tank etc complete all lead and for all lifts complete & as directed by engineer-in-charge.

1

-

2112187

... More
Earthwork excavation for foundation of structures by Mechanical Means as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting bracing, removal of slumps and other deletrious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., with complete all lead and for all lifts complete & as directed by engineer-in-charge. For 0 to 3.0 mtr depth, In In Ordinary / All soils / Hard soil. For Pump House, PW Sump, OHT's, clarifier

5899.94

-

549520.41

... More
Earthwork in surface excavation in Ordinary soil for levelling and lowering the ground manually ( Other than foundation of building, culverts, road drains and trenches of pipe lines and cables) and removing the excavated stuff to a distance not exceeding 50m and lift upto 1.5m excavated surface levelled and neatly dressed, disposed earth to be levelled incluiding breaking of clods and neatly dressed as per specifications with complete all lead and for all lifts complete & as directed by engineer-in-charge. For approach road from Footbridge to existing road

540

-

143953.2

... More
Construction of Sub-grade and earthen shoulders with approved materials Gravel/Murrum with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No.300-2 complete as per specifications (including cost of earth, watring charges & compaction by vibratory roller) with complete all lead and for all lifts complete & as directed by engineer-in-charge. For Jackwell, Approach road from Footbridge to existing road

2174.73

-

1406267.41

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specifications including spreading in uniform thickness, hand packing, rolling with 3-wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complate as per specification.A by mannual means. (MORTH-Specification No.404) with complete all lead and for all lifts complete & as directed by engineer-in-charge- Type B-11.2mm for grading -III. For Approach road, For road restoration at PWRM,PWRM, PWGM, Distribution system etc

4187.36

-

11001241.56

... More
Providing and laying of semi dense bituminous concrete using crushed aggregates of specified grading, premixed with bituminous binder and filler, transporting hot mix to worksite, laying with a paver finished to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per morth specification clause no.508, complete with complete all lead and for all lifts complete & as directed by engineer-in-charge - using 120 TPH, capacity asphalt batch mix plant with sensor paver Gr-I,(35mm to 40mm) with 4.5% Vg-30 bitumein

40

-

320966

... More
Providing and laying Filter material underneath pitching in slopes complete as per drawing and technical specification (MORTH Specification No.2504) complete with complete all lead and for all lifts complete & as directed by engineer-in-charge, For round the well (Water protection), Approch road (Both Sides)

176.84

-

443399.77

... More
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications A. Stone / Boulder (MORTH Specification No. 2504) complete with complete all lead and for all lifts complete & as directed by engineer-in-charge. For round the well (Water protection), Approch road (Both Sides)

730.71

-

1261848.48

... More
Earth work excavatoin for water Supply pipe line trenches beyond 600mm Trenches width as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work complete with complete all lead and for all lifts complete & as directed by engineer-in-charge. By Mechanical means For 0 to 3.0 mtr depth - In In Ordinary / All soils / Hard soil

16466.03

-

1903802.39

... More
-do- For 0 to 3.0 mtr depth- Ordinary rock comprising of lime stone, sand stone, hard laterite, fissured rock, conglomerate or other soft or disintegarted rock which may be querried or split with crow bars. Boulders which do not require blassting having max. Dia in any direction of more than 300mm; found lying loose on the surface or embedded in river bed, soil, talus, slope wash and terrace material of dissimilar origin - with all lead and lift complete & as directed by engineer-in-charge

9879.62

-

1523141.02

... More
-do- For 0 to 3.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery with all lead and lift complete & as directed by engineer-in-charge

6586.41

-

5965509.13

... More
Cutting road surface for pipeline trenches and disposing off the excavated stuff with all lead & lift as directed including barricading danger lighting, with all lead and lift complete & as directed by engineer-in-charge For cutting of asphalt road, for PWRM,RWRM,PWGM, Distribution

4127.36

-

2805903.15

... More
-do- For cutting cement concrete road-with all lead and lift complete & as directed by engineer-in-charge

13339.28

-

18193977.56

... More
-do- For cutting macadam road-with all lead and lift complete & as directed by engineer-in-charge

9426.02

-

3491680.59

... More
Demolition of R.C.C Structures- Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. i) Lime/Cement Concrete. i.By Manual Means. - i) lime/Cement Concrete. i. By Manual Means :B. Cement Concrete Grade M-15 &M-20-with all lead and lift complete & as directed by engineer-in-charge

738

-

440084.16

... More
Demolition of Exisiting Brick/Stone masonry Structures:Dismantling of existing structures like culverts, barrages, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled materials, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications, iii) Dismantling Stone Masonry. B Rubble Stone masonry in cement mortor-with all lead and lift complete & as directed by engineer-in-charge

738

-

228337.2

... More
Removal of Telephone / Electrical poles and lines including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and stacking the serviceable and unserviceable material separately with all lead and lift complete & as directed by engineer-in-charge

175

-

40656

... More
Providing murrum/Gravel bedding for the pipeline trenches including watering and consolidation by punners tc,. Complete with all lead and lift (In black cotton soil and rock reaches) with all lead and lift complete & as directed by engineer-in-charge

12658.54

-

3510086.56

... More
Extra charges for excavation in all classifications in watery situation or foul conditions may be paid as under towards dewatering with an overnight recuperation upto one metre depth and there for quantity with all lead and lift complete & as directed by engineer-in-charge

16155.42

-

1608595.17

... More
Manufacturing, providing, transporting, rolling, lowering, laying & Jointing, testing, commissioning of ERW (Electric Resisance Welded)/SAW (Sub-merged Arc Welded) MS pipes (Fe-410 grade) conforiming to IS 3589-2001 with latest amendments including perfect linking and welding of joints to correct position including cost and conveyance of pipes and materials with all lead and lift, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both a factory and sit etc complete as per detailed specifications. With inside CM 1:1.5 lining of minium 10mm thick upto 610mm OD & minimum 12 mm thick beyond 610mm OD and outside minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangement for procuring water for testing) -with all lead and lift complete & as directed by engineer-in-charge - MS 610 mm dia - 6.40mm thick, For RWRM, PWRM

13850

-

114018324.5

... More
-do- MS 355.60 mm dia - 6.40mm thick - with all lead and lift complete & as directed by engineer-in-charge.For RWRM, PWRM

150

-

748731

... More
Manufacturing,providing,transporting,rolling,lowering,laying and joining, testing and commissioning of MS specials of minimum 8mm thick conforming to IS 7322:1985 with latest amendments, perfect linking and welding of joints to correct position including cost and conveyance of material with all lead and lifts, cost of labour and giving satisfactory hydraulic test as per IS 3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc.complete as per detailed specification with inside lining two coats of food grade epoxy painting of approval make with each coat of 250 micron,thick(After dry) over one coat of food grade epoxy primer of approved make with minimum of 50 microns thick and outside 25mm thick coating in CM 1:3 by providing 50*50mm wel mesh including loading and unloading of pipe for the following category to suit MS Pipe. The weight of the MS shell only be considered before lining and coating for arriving at the rate. The thickness of plate will be specified with all lead and lift complete & as directed by engineer-in-charge, above 500 mm dia Pipe

12100

-

1943139

... More
Supply and delivery to work site, loading, unloading, stacking and fixing of Resilient seated soft sealing Sluice Valves with body, bonnet of Ductile Iron of grade GGG40/50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/ DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings (minimum 2 'O' rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS etc with all lead and lift complete & as directed by engineer-in-charge- DI Sluice Valve 150mm dia PN 16, for RWRM,PWRM,PWGM,Distribution etc

67

-

1284794.68

... More
-do- DI Sluice/Scour Valve 350mm dia PN 16 - with all lead and lift complete & as directed by engineer-in-charge.

17

-

1904721.99

... More
-do- DI Sluice/Line Valve 600 mm dia PN 16 - with all lead and lift complete & as directed by engineer-in-charge.

4

-

1024659.56

... More
Supply, conveying to work site, loading, unloading, stacking and fixing of single chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/50. All internal parts such as float, shell etc., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside colour bule RAL5005. The valves shall have drain plug of not less than 15 mm nominal pipe thread complete with all lead and lifts. the valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation - with all lead and lift complete & as directed by engineer-in-charge. DI Air Valve 150mm dia PN 16

29

-

1343713.26

... More
Supply and fixing of cast steel double flanged dual plate check valve conforming to API 594 with latest amendments as detailed below of following diameters and types conveying to work site, loading, unloading, stacking etc., complete with all lead and lift. The rates are inclusive of cost of Bolts and Nuts - with all lead and lift complete & as directed by engineer-in-charge - CS Dual plate check Valve - 600mm dia with 300 class

2

-

197936.36

... More
Supply and fixing of pressure relief valve and types conveying to work site, loading, unloading, stacking etc., complete with all lead and lift. The rates are inclusive of cost of Bolts and Nuts-with all lead and lift complete & as directed by engineer-in-charge - DI 150mm dia Pressure relief valve PN 16.

2

-

152255.84

... More
Supplying and fixing of DI double flanged wafer type (concentric)/double eccentrically disc, butterfly valves conforming to DIN 335/ IS 13059 with renewable soft seal on the disc and body seat face of nickel weld overlay micro finished / Integral seat with power or liquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Face to face dimensions as per EN 558-1 basic series 14 (DIN 3203 F4) or AWWA C 504: 80 or BS 5155 or IS 13095. The valves shall be supplied along with the required number of standard make galvanised bolts and nuts. The flanges drilling standard is IS 1538. Hence, drilling of hole in the valves shall match with the pipe flange drilling standard. The valves are to be suitable for buried operation with the gear box sealed and lubricated for life time operation with all lead and lift complete & as directed by engineer-in-charge - DI Valve 600mm dia PN 16

2

-

492074.62

... More
For Canal crossing work - Earthwork in excavation for foundations of structures by Mechanical Means as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc. with all lead and lift complete & as directed by engineer-in-charge Ordinary rock comprising of lime stone, sand stone, hard laterite, fissured rock, conglomerate or other soft or disintegarted rock which may be querried or split with crow bars. Boulders which do not require blassting having max. Dia in any direction of more than 300mm; found lying loose on the surface or embedded in river bed, soil, talus, slope wash and terrace material of dissimilar origin - with all lead and lift complete & as directed by engineer-in-charge

120

-

44836.8

... More
Providing and laying vibrated cement concrete 1:1.5:3 proportion for RCC columns below and above G.L with 20 mm and down size of approved gradation hard aggregate including cost and conveyence af all lead lift with plywood or steel form work,centering including machine mixing laying,viberating and smooth finishing the exposed faces in C.M 1:3,12 mm thick etc (excluding cost of reinforcement) with all lead and lift complete & as directed by engineer-in-charge

50.62

-

690490.21

... More
Providing and laying vibrated M30 design mix for RCC work with 20 mm and down size of approved gradation hard broken granite, basalt. Trap or any other approved hard aggregate including cost and conveyance of all materials with all lead and lift including weight batch plant mixing, centreing plywood / steel form work, scaffolding tampling, curing, cement mortar plastering in C.M. 1:3 proportion 12 mm. thick for inside surface etc., complete. (excluding cost of reinforcement) for R.C.C. covering slab (Flat slab) - with all lead and lift complete & as directed by engineer-in-charge

30

-

409830

... More
Providing and laying cement concrete 1:2:4 proportion (excluding cot of reinforcement) with 20mm and down size metal of approved gradation hard broken granite, trap, basalt or with any other approved hard aggregate including cost and conveyance of all materials with an initial lead of 5 ks, and lift of 2 mtrs. and placing the same above or below ground level including plywood/steel form work, machine mixing, laying, tamping, curing etc., complete including smooth finishing the exposed faces with CM 1:4 proportion 12mm thick wherever necessary etc - with all lead and lift complete & as directed by engineer-in-charge. For Anchor Blocks/Thrust blocks.

443.59

-

2987059.65

... More
Providing, laying, spreading and compacting Crushed stone material aggregates of granite /trap/basalt specific sizes to water bound macadam specifications including spreading in uniform thickness, hand packing, rolling with 3-wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per Specification. A. By manual means. MORTH Specification No.404 Crushable type such as Moorum or Gravel for grading III- with all lead and lift complete & as directed by engineer-in-charge. For Macadam Road

9426.02

-

23371910.85

... More
Providing and applying primer coat with S.S. bitumen emulsion on prepared surface of granular base such as WMM including clearing of road surface and spraying primer at the rate of 0.60 kg / sqm using mechanical means complete as per specifications (MORTH Specification No. 502) with all lead and lift complete & as directed by engineer-in-charge. For Asphalt Road

37386.06

-

1360852.58

... More
Providing and laying bituminous macadam on prepared surface with crushed coarse aggregates as per design mix formula for base / binding course including loading of aggregates with F.E. loader, hot mixing of stone aggregates and bitumen in hot mix plant, transporting the mixed material in tipper to paver and laying mixed materials with paver finisher to the required level and grade, rolling by power roller to achieve the desired density, but excluding cost of primer / tack coat with lead, lift and cost of all materials, labour, HOM of machineries complete as per specifications. (MORTH Specification No. 504) using 120 TPH capacity A.B.M.P. with sensor paver Gr-I (80 mm to 100mm) with 3.3% VG-30 Bitumen - with all lead and lift complete & as directed by engineer-in-charge. For Asphalt Road

3739.11

-

24574963.96

... More
Providing and applying tack coat using 80/100 grade bitumen (VG10) on the prepared black topped at 2.5 kg per 10 sqm, heating bitumen in boiler fitted with spray set (excluding cleaning of road surface) including cost of all materials, labour, HOM of machineries complete as per specifications.(MORTH Specification No. 503) with all lead and lift complete & as directed by engineer-in-charge. For Asphalt Road

37386.06

-

560417.04

... More
Providing and laying 20 mm thick mix seal surfacing Type “A” on prepared surface as wearing course with specified graded crushed aggregates of 5.6mm and 11.2mm size 0.027 cum/sqm premixed with bituminous binder at 2.15kg/sqm of VG-30 (60/70), in hotmix plant 40-60 tonne, transporting the mixed materials in tipper and laying with machanical paver finisher to required level and grade, rolling with power roller 8-10 tonne excluding cost of tack coat including cost of all materials, labour, HOM of machineries complete as per specifications.(MORTH clause No.508) (using CRMB 55 grade bitumen) using 120 TPH capacity H.M.P. with sensor paver Gr-I (80 mm to 100mm) with 3.1% VG-30 Bitumen - with all lead and lift complete & as directed by engineer-in-charge. For Asphalt Road

37386.06

-

6524241.33

... More
Providing, laying, spreading and compacting specified graded, gravel or any other sourse material 60% and crushed stone aggregates of granite / trap / basalt 40% in sub-base course close grading-1 including premixing the material at OMC in mechanical mixer (Pug mill), carriage of mixed material, sperading in uniform layers with motor grader on prepared base and compacting with power roller to achive the desired density incluiding all materials, labour,HOM lighting, gurding, barricading and maintenance of diversion complete as per specifications with all lead and lift complete & as directed by engineer-in-charge. For Cement concrete Road

261.24

-

1500993.61

... More
Constructing un-reinforced, plain cement concrete for pavements using Grade concrete M30 over a prepared base with OPC coarse aggregates at 0.69 cum, fine aggregates at 0.46 cum, coarse and fine aggregate conforming to IS:383-2016, with superplastizer at 3 lts conforming to IS 9103-2008. mixed in a concrete mixer of not less 0.6 cum capacity and approximate weigh batcher as per approved mix design, laid in approved fixed side form work ( steel channel, laying and fixing of 125 micro thick polythene film, wedges, steel plates including levelling the form work as per drawing). & spreading the concrete with shovels, rackers compacted using needle, screed and plate vibrator and finished with floaters in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, including groove cutting charges, joint filler, separation membrane of impermible plastic sheet of 125 micron, sealant primer, joint sealant, admixtures as approved, curing compound, finishing to lines and grades, textured with texturing machine, and cutting including cost of all materials labour, ,hire charges of machineries, all lead & lift charges etc., complete as per specifications. --do-- with OPC at 360 kg/cum and coarse aggregates 0.69 cum, fine aggregates 0.46cum-with all lead and lift complete & as directed by engineer-in-charge. For Cement concrete Road

10910.78

-

57493809.67

... More
Construction of RCC valve chambers 2mx2m: - Earthwork in excavation for foundations of structures by Mechanical Means as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc.complete- with all lead and lift complete & as directed by engineer-in-charge - In all soil

2912.55

-

932336.38

... More
Earthwork in excavation for foundations of structures by Mechanical Means as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc.complete- with all lead and lift complete & as directed by engineer-in-charge - In all disintegrated road, soft rock

2803.71

-

1347743.4

... More
Providing and laying in position plain cement concrete of mix M10 with OPC cement @ 200 kgs with 40mm and down size graded granite metal coarse aggregates @ 0.892 cum and fine aggregates @ 0.465 cum machine mixed, concrete laid in layers not exceeding 15 cms thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications with all lead and lift complete & as directed by engineer-in-charge. VC PCC

236.12

-

1332961.15

... More
Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320 kgs with with 20mm and down size graded granite metal, coarse aggregates @ 0.878 cum and fine aggregates @ 0.459 cum with super plasisiser @ 3 ltrs confirming to IS 1903-1999 reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick vibrated for all works in foundation plinth and ground for roof slabs, starir case, lintels, retaining walls, return walls, walls (any thickness) including attached pilasters, colums, Piers abutments pillers, posts, struts, butteresses, string are lacing coarses, parapets, coaping, bed blocks, anchor blocks, plait window Cills, fillets etc including cost of all materials, labour HOM of machinery, curing complete as per specifications with all lead and lift complete & as directed by engineer-in-charge- For Raft slab, Long wall, short wall & slab.

1410.73

-

9397253.43

... More
Providing 12mm thick cement plaster in single coat with cement mortar 1:6 to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing compelte as per specification with all lead and lift complete & as directed by engineer-in-charge -For Inside & outside.

9426.97

-

1945820.88

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m depth including cost of all materials, laobur complete as per specifications with all lead and lift complete & as directed by engineer-in-charge.

10751.97

-

3361280.86

... More
Providing and fixing M.S. Inspection door of size 60 cms x 60 cms including M.S. frame, size 50x50x6 mm and shutters of 3mm thickness with hinges at top and locking arrangements painting with all lead and lift etc with all lead and lift complete & as directed by engineer-in-charge.

443

-

862233.05

... More
HDD Works crossing of NH & SH roads:- Excavation for ramming / jacking pits and receiving pit. The work includes cutting of asphalted / concrete surface, excavation in all types of soil and strata, dewatering, disposal of debris, refiling the trenches with consolidation, restoration of road surface to normal surface by concreting/asphalting etc., complete. Size up to 5 mts X 3 mts - depth up to 4 mts - with all lead and lift complete & as directed by engineer-in-charge

20

-

3311386

... More
Installation of product pipe by manual jacking method-Manufacturing, providing,transporting, rolling, lowering, laying & jointing, testing, commissioning of ERW (Electric Resistance Welded), SAW (Submerged Arc Welded) MS pipe (Fe-410 grade)conforming to IS 3589-2001 with latest amendments including perfect linking welding of joints to correct position including cost and conveyance of pipes and materials with all lea., lift, cost of labour, loading and unloading of pipes for the following diameters with specified thickness of plate as noted below including bailing out of water wherever necessary for laying of MS carrier pipe of suitable dia including inside and outside of casing pipe painted with two coats of Anti corrossive tankmastic paint. Installation of steel pipe by Ramming / Jacking method to cross Railway track /NH /BDA /BBMP/Other roads/Existing utilities / NALA crossings,filling the gap between casing pipe and carrier pipe with quarry grit using compressor with all necessary equipments, plants etc, complete. Suitable spacers 0f HDP/MS or other similar material should be provided in between carrier & casing pipe to prevent carrier pipe forming metallic contact with casing pipe. The rates are inclusive of all taxes and duties. Note : a. The cost of jacking is inclusive of cost M.S. casing pipe of specified thickness b. The cost of carrying pipe is separate and provision shall be made as per site requirement c. The cost of Jacking includes all leads lifts, cost of consumables, fuel charges, labour and Taxes and duties. d. The cost of jacking and receiving pits shall be proposed separately as per site requirement - with all lead and lift complete & as directed by engineer-in-charge - For Jacking of 700 mm dia & 10 mm thick M.S. Casing Pipe.

320

-

9877955.2

... More
-do- For Jacking of 1000 mm dia & 12 mm thick M.S. Casing Pipe.

120

-

5178578.4

... More
Providing and constructing granite, trap, basalt or any other approved hard stone UCR masonry in CM 1:4 proportion (excluding pointing) in courses not less than 20 cms high including scaffolding curing etc., complete with all lead & lifts for all materials etc if any with all lead and lift complete & as directed by engineer-in-charge. For Pump houses,Chemical houses.

24.25

-

80344.37

... More
Providing and constructing burnt brick masonry with approved quality of non-modular bricks of standard size of class designation 5.0 Newton per sqmm (table moulded) with cement mortar 1:6 for basement and superstructure including cost of materials, labour charges, scafflolding, curing complete as per specifications In CM 1:6, etc if any with all lead and lift complete & as directed by engineer-in-charge. For ground Floor in Super Structure, First Floor, For Pump houses,Chemical houses.

48.02

-

341335.76

... More
Providing Mathi / NandI wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as specifications etc if any with all lead and lift complete & as directed by engineer-in-charge

2.52

-

10389.66

... More
Providing and fixing in position fully paneled Mathi / Nandi wood shutters doors, styles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, HOM of machineries complete as specifications etc if any with all lead and lift complete & as directed by engineer-in-charge

2.52

-

10389.66

... More
Providing 12mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications etc if any with all lead and lift complete & as directed by engineer-in-charge. For Ground Floor & first Floor.

164.37

-

33238.9

... More
Providing 20mm thick cement plaster in single coat with cement mortar 1:6, to stone masonry and concrete surface including rounding off corners wherever required smooth rendering, :including Providing and removing scaffolding, cost of materials, labour, curing complete as per specifications etc if any with all lead and lift complete & as directed by engineer-in-charge. For Ground Floor & first Floor.

128.86

-

31953.41

... More
Providing 12mm thick cement plaster in single coat with cement mortar 1:3, to ceiling including rounding off corners wherever required smooth rendering, : including Providing and removing scaffolding, cost of materials, labour, curing complete as per specifications etc if any with all lead and lift complete & as directed by engineer-in-charge. For Ground Floor & first Floor.

124

-

30748.28

... More
Providing ruled pointing 20mm deep to coursed stone masonry with cement mortar 1:3, after raking joints to depth of 20mm nicely lining, including cost of materials, labour, curing complete as per specifications etc if any with all lead and lift complete & as directed by engineer-in-charge.

10.28

-

1555.06

... More
Providing mosaic flooring with cast-in-situ 40mm thick using marble chips and polishing to granolithic finish with under layer of 28mm thick cement concrete M-15 with stone aggregate 12mm and down size, and top layer 12mm thick with white cement without any pigment in top layer only using white, black, chacolate, yellow or baroda green marble chips of size from 7 to 10 nominal size laid in cement marble powder mixed 3:1 (3 cement : 1 marble powder by weight) in proportion of 4:7 (4 cement marble powder mix :7 marble chips by volume) curing polishing oxalic acid wash, wax polish, including cost of materials, labour, complete as per specifications etc if any with all lead and lift complete & as directed by engineer-in-charge. For Ground Floor & first Floor.

50.68

-

84036.06

... More
Providing and applying two coats with oil bound washable distemper of approved brand and shade on wall surface including priming coat with distemper primer after throughly brooming surface free from motar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labours, complete as per specification and direction etc if any with all lead and lift complete & as directed by engineer-in-charge. For Ground Floor.

193.28

-

22762.59

... More
-do- For first Floor etc if any with all lead and lift complete & as directed by engineer-in-charge.

89

-

10748.53

... More
-do- For first Floor etc if any with all lead and lift complete & as directed by engineer-in-charge.

63.25

-

12717.04

... More
Providing and applying painting two coats (excluding priming coat) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning surface of all dirt, dust, and foreign matter, sand papering including cost of materials, labour, etc if any with all lead and lift complete & as directed by engineer-in-charge. For Ground Floor.

45.48

-

4723.1

... More
-do- For first Floor etc if any with all lead and lift complete & as directed by engineer-in-charge.

17.21

-

1838.89

... More
Providing and fixing Motor of 2.5 HP motor or suitable HP to drive with gear system to produce 10 RPM or suitable for blade assumble each blade assemble having 2 blades of size 1.2m long 0.06m width diameter of blade assumble 1.2m with central shaft of 1.2m long one end shaft resting on bail bearing and other side free for rotation etc allied accessories if any with all lead and lift complete & as directed by engineer-in-charge.

2

-

60000

... More
Supplying PVC ringtite Pipes conforming to I.S. 4985 - 2000 with latest amendments and conveying to worksite, rolling and lowering into trenches,laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloding at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (including cost of specials) with jointing of approved type,with all labour, with all lead & lift including encasing the pipe alround to a depth of not less than 15cms with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS ( contractor will make his own arrangements for procuring water for testing) etc if any with all lead and lift complete & as directed by engineer-in-charge. For PVC 63 mm Diameter Pipes/6KSC

60

-

6241.8

... More
-do- For PVC 32 mm Diameter Pipes/10KSC any with all lead and lift complete & as directed by engineer-in-charge.

24

-

1527.12

... More
Supplying, laying, jointing, testing and commissioning of G.I. Pipes conforming to I.S. 1239:1990 with latest amendments including fixing collars, elbows, tees, bends,gland cocks and other fitting ( excluding cost of specials) with cuts and threads wherever necessary including conveying the materials to workspot including testing for water tightness, with all lead & lifts (contractor willmake his own arrangements for procuring water for testing) etc if any with all lead and lift complete & as directed by engineer-in-charge. For GI 40 mm Diameter HD pipes

18

-

6490.26

... More
-do- For GI 32 mm Diameter HD Pipes any with all lead and lift complete & as directed by engineer-in-charge.

18

-

5872.14

... More
-do- For GI 25 mm Diameter HD Pipes any with all lead and lift complete & as directed by engineer-in-charge.

18

-

4145.04

... More
Providing and fixing Gun Metal Gate valve confoming to I.S. Specification of approved make as per directions including all lead and lift etc., complete any with all lead and lift complete & as directed by engineer-in-charge.For 25 mm Diameter

4

-

1600.48

... More
-do- For 32 mm Diameter etc if any with all lead and lift complete & as directed by engineer-in-charge.

4

-

2540.4

... More
-do- For 40 mm Diameter etc if any with all lead and lift complete & as directed by engineer-in-charge.

4

-

3084.8

... More
Providing of Internal & external electrification including lighting and fans arrangement to Chemical house with Ground floor and first floor including all lead and lift etc., complete any with all lead and lift complete & as directed by engineer-in-charge

1

-

79046

... More
Earthwork excavation for foudation of structures by Mechanical Means as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading,danger lighting. bracing, removel of slumps and other deleterious matter, dressing of side and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc, complete any with all lead and lift complete & as directed by engineer-in-charge For 0 to 3.0 mtr depth- Ordinary rock comprising of lime stone, sand stone, hard laterite, fissured rock, conglomerate or other soft or disintegarted rock which may be querried or split with crow bars. Boulders which do not require blassting having max. Dia in any direction of more than 300mm; found lying loose on the surface or embedded in river bed, soil, talus, slope wash and terrace material of dissimilar origin - with all lead and lift complete & as directed by engineer-in-charge. For Pump houses, Chemical house, OHT's,CLARIFIER CUM FLOCCULATOR TANK and others

4750.88

-

590011.79

... More
-do- For 0 to 3.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery with all lead and lift complete & as directed by engineer-in-charge.For Pump houses, Chemical house, OHT's and others

5640.1

-

4087944.48

... More
Supplying of S&S RCC spun pipes Np-3 class conforming to Is 458-1988with latest amendments and conveying to worksite rolling ad lowering into trenches laying ture to line and level including loadn and unloading at both distinations and jointing to pipes and specials (excluding cost of specials) including perfect linking of joints with jack to correct position including cost of jointing materials, ie rubber rings confirming to Is for S&S RCC pipes with all lead and lifts andas directed and givign necessary hydraulic test to the required pressure as per Iss and testing and commissioning, etc complete with all lead and lift complete & as directed by engineer-in-charge. For RCC 400mm dia NP-3

150

-

383815.5

... More
supply and delivery to work site, loading, unloding, stacking and fixing of Resilient seated soft sealing Sluice Valves with body, bonnet of Ductile Iron of grade GGG 40/50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face dimension as per BS 5163-89/IS 14846-2000/DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings ( minimum 2 "O" rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS etc. complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge. DI 400 mm dia sluice valve PN 10

10

-

1352733.6

... More
-do- DI 250 mm dia sluice valve PN 10 - with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge.

24

-

1098508.8

... More
Supplying PVC ringtite Pipes conforming to I.S. 4985 - 2000 with latest amendments and conveying to worksite, rolling and lowering into trenches,laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloding at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials ( excludind cost of specials) with jointing of approved type,with all labour, with all lead & lift including encasing the pipe alround to a depth of not less than 15cms with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS ( contractor will make his own arrangements for procuring water for testing) etc. complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge. For 75mm dia 6 KSC

50

-

7239.5

... More
Fabricating and supplying MS angular trusses for all spans as per approved designs and drawing. The entire truss is anchored suitably by using 4no.s of M S anchor bolts at each support, with base plate and shoe plate. the work includes cutting, straightening, placing in position of M S angle and welding wherever necessary, and applying one coat of red oxide primer coat to all the members including cost of all materials, labour charges,& hire charges of machineries for cutting, welding, grinding & erection equipments, etc., complete as per specification etc complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge. For Foot bridge cum Turn Table

679.43

-

140207.17

... More
Providing, fixing and fabrication of Scraper Mechanism with Rubber Pad at bottom including all materials, labour charges & hire charges of machineries for cutting, welding, grinding & erection equipments, etc., complete as per specification etc complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge

1

-

365000

... More
Providing, fixing and fabrication of Flacculator including all materials, labour charges & hire charges of machineries for cutting, welding, grinding & erection equipments, etc., complete as per specification etc complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge

9388.32

-

954886.03

... More
Providing, fixing and fabrication of turn table with heavy duty ball bearing with oil lubrication system to cater for 10 tonnes load and of 1.15 m diameter including all materials, labour charges & hire charges of machineries for cutting, welding, grinding & erection equipments, etc., complete as per specification etc complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge

1

-

185000

... More
Providing, installing & commissioning motar for the movement of turn table with scraper mechanism of 5HP capacity/1000 RPM and chain sprocket ratio, worm gear box ratio & the bevel gear ratio are to be adjusted in such a way to get the required RPM of the scraper mechanism as per the instructions of the Engineer in-charge, peripherial dia at wall centre 16.30m thickness of wall 300mm etc complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge

1

-

85000

... More
Providing, installing & commissioning Motor of 1.5 HP motor or suitable HP motor to drive with gear system to produce 6 RPM or suitable RPM for blade assembly. Each blade assembly having 4 blades of size 250mm x 350mm & 0.50m wide, with central shaft of 2.75m long - one end shaft resting on ball bearing and other side free for rotation etc with allied accesories complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge

4

-

100000

... More
Providing and fixing Motor Starter with all elecrical installation like cables etc complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge

5

-

130000

... More
Providing Rotor Type switch for turn table to drive motor with all accessories etc complete with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge

1

-

15000

... More
Providing and fixing V notch of MS 3 mm thick with all necessary with all lead & lifts with all lead and lift complete & as directed by engineer-in-charge-

2

-

21000

... More
-do- Extra fo use of water proofing compound in Cement concrete of mix 1:1:2, at one kg of compound per bag of cement.For Sumps

135.81

-

30388.85

... More
Providing and fixing RCC finial and ventilators as per approved design and specification with formwork and protected with wire mesh. The plinth to be of RCC circular pillars and canopy with an ornamental finish at top. The first 22.50cms height to be covered with RCC panelling as per detailed drawing with all lead and lift complete & as directed by engineer-in-charge. For Sump.

2

-

12367.58

... More
Supplying, laying of CI flanged pipe true to line/hoisting of CI flanged pipe confirming to IS 7181-1986 with latest ammendements in position and aligning to correct plumb including cost of jointing material & specials conveying to work spot with all lead and lifts etc complete & as directed by engineer-in-charge. CI flanged 450 mm dia Pipes.

10

-

171245.5

... More
-do-CI 450 mm dia Double Flanged bends- with all lead and lifts etc complete & as directed by engineer-in-charge.

4

-

46000

... More
Supplying, & Fixing CI puddle flanges confirming to IS 7181-1986 with latest ammendements in position for RCC walls aligning including hoisting and conveying them to work spot with all lead and lift etc complete with all lead and lifts etc complete & as directed by engineer-in-charge. For CI Puddle flanges 1 m length-400 mm dia

2

-

28191.12

... More
Providing and laying flooring with M15 cement concrete 40 mm thick using broken granite 20mm and down size laid to line and level in one layer and finish with a floating coat of neat cement, including cost of materials, labour, curing, complete as per specifications etc with all lead and lift complete & as directed by engineer-in-charge.

80.16

-

30455.99

... More
Providing 20mm thick cement plaster in single coat with cement mortar 1:6, to stone masonry and concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications etc with all lead and lift complete & as directed by engineer-in-charge.

180.44

-

47834.64

... More
Providing, supplying, fabricating and installation of Structural Steel Girder for 3MT Gantry Girders for chain & pulley arragement as per relevant IS specifications etc with all lead and lift complete & as directed by engineer-in-charge.(The Design of 3MT Gantry girder should be get it approved from competent authority before execution)

1215.98

-

123677.33

... More
Providing all Electrification works to Pumphouse with complete all lead and for all lifts complete & as directed by engineer-in-charge.

1

-

81845

... More
Supplying, & Fixing CI puddle flanges confirming to IS 7181-1986 with latest ammendements in position for R C C walls aligning including hoisting and conveying them to work spot etc complete all lead and for all lifts complete & as directed by engineer-in-charge. For 250 mm dia CI puddle pipe for fixing sludge pipe

4

-

27653.8

... More
Supplying of S&S RCC spun pipes Np-3 class conforming to Is 458-1988with latest amendments and conveying to worksite rolling ad lowering into trenches laying ture to line and level including loadn and unloading at both distinations and jointing to pipes and specials (excluding cost of specials) including perfect linking of joints with jack to correct position including cost of jointing materials, ie rubber rings confirming to Is for S&S RCC pipes with all lead and lifts andas directed and givign necessary hydraulic test to the required pressure as per Iss and testing and commissioning. etc complete all lead and for all lifts complete & as directed by engineer-in-charge. 300 mm dia RCC, S&S, NP-3 pipe

56.4

-

101395.92

... More
Earth work excavatoin for water Supply pipe line trenches beyond 600mm Trenches width as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work complete with complete all lead and for all lifts complete & as directed by engineer-in-charge. By Mechanical means For 0 to 2.0 mtr depth - In In Ordinary / All soils / Hard soil. For PWRM, PWRM-Ips, Distribution network.

56185.25

-

6496138.6

... More
-do- For 0 to 2.0 mtr depth- Ordinary rock comprising of lime stone, sand stone, hard laterite, fissured rock, conglomerate or other soft or disintegarted rock which may be querried or split with crow bars. Boulders which do not require blassting having max. Dia in any direction of more than 300mm; found lying loose on the surface or embedded in river bed, soil, talus, slope wash and terrace material of dissimilar origin - with all lead and lift complete & as directed by engineer-in-charge. For PWRM, PWRM-Ips, Distribution network.

38037.89

-

5864301.5

... More
-do- For 0 to 2.0 mtr depth- Hard rock - Any rock or cement concrete or RCC, excavation by using mechanical plant / machinery with all lead and lift complete & as directed by engineer-in-charge

36603.75

-

33153114.49

... More
Providing, laying, spreading and compacting specified graded, gravel or any other sourse material 60% and crushed stone aggregates of granite / trap / basalt 40% in sub-base course close grading-1 including premixing the material at OMC in mechanical mixer (Pug mill), carriage of mixed material, sperading in uniform layers with motor grader on prepared base and compacting with power roller to achive the desired density incluiding all materials, labour,HOM lighting, gurding, barricading and maintenance of diversion complete as per specifications with all lead and lift complete & as directed by engineer-in-charge. For Cement concrete road

9683.74

-

15561479.67

... More
Earth work excavation by manual means for pipeline trenches (except building works) including depositing on bank with all lead including shoring, strutting, barricading, danger lightining and using sight rails and boning rods at every 100 meters, wherever necessary as directed in the starta with all lead and lift complete & as directed by engineer-in-charge - In all soils mixed wit boulders upto 30cms. Size and exclusive of disintegarted rock For 0 to 2 mtr depth, For PWGM, Distribution

5802.25

-

1627531.12

... More
-do- For 0 to 2 mtr depth - disintegrated rock, soft rock, soft shale, medium hard rock compresing of lime stone, sand stone, hard shale, schiest, fissured rock without resorting to blasting- with all lead and lift complete & as directed by engineer-in-charge For PWGM, Distribution

4385.96

-

2779821.45

... More
-do- For 0 to 2 mtr depth -In hard rock by chistelling - with all lead and lift complete & as directed by engineer-in-charge For PWGM, Distribution

3974.6

-

10148664.15

... More
Manufacturing, providing, transporting, rolling, lowering, laying & Jointing, testing, commissioning of ERW (Electric Resisance Welded)/SAW (Sub-merged Arc Welded) MS pipes (Fe-410 grade) conforiming to IS 3589-2001 with latest amendments including perfect linking and welding of joints to correct position including cost and conveyance of pipes and materials with all lead and lift, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both a factory and sit etc complete as per detailed specifications. With inside CM 1:1.5 lining of minimum 10mm thick upto 610mm OD & minimum 12 mm thick upto 610mm OD and outside minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangement for procuring water for testing) -with all lead and lift complete & as directed by engineer-in-charge 610 mm dia, 5.6 mm thick

15

-

113835.9

... More
-do-508 mm dia, 5.6 mm thick

435

-

2763381

... More
-do- 457 mm dia 5.6 mm thick

600

-

3473400

... More
-do- 406 mm dia 5.6 mm thick

710

-

3671268

... More
-do- 355 mm dia 5.6 mm thick

2370

-

10953855.6

... More
-do- 273.1 mm dia 5.6 mm thick

2200

-

8168160

... More
-do- 219 mm dia 5.6 mm thick

5220

-

16367884.2

... More
Supplying and fixing of DI specials with ISI mark confirming to IS 9523/2000 suitable for jointing 100 mm to 600 mm dia DI pipes coated with rust prevention coating s as below : I) External coating : a) Metalic zink with finishing layer of bituminious as per Annexure A of IS :9523 / 2000 b) Zink rich paint with finishing layer of bituminious as per Annexure A of IS :9523 / 2000, c) Bituminous paint as per Annexure C of IS :9523 / 2000, II) Internal Lining : a) Portland Cement ( with or without additives) morter as per Annexure – B Of IS : 9523/2000 b) Cement Morter with coat as per Annexure B Of IS : 9523/2000, c) Bituminous paint as per Annexure C of IS :9523 / 2000 etc with all lead and lift complete & as directed by engineer-in-charge.

5000

-

412200

... More
Manufacturing,providing,transporting,rolling,lowering,laying and joining, testing and commissioning of MS specials of minimum 8mm thick conforming to IS 7322:1985 with latest amendments, perfect linking and welding of joints to correct position including cost and conveyance of material with all lead and lifts, cost of labour and giving satisfactory hydraulic test as per IS 3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc.complete as per detailed specification with inside lining two coats of food grade epoxy painting of approval make with each coat of 250 micron,thick(After dry) over one coat of food grade epoxy primer of approved make with minimum of 50 microns thick and outside 25mm thick coating in CM 1:3 by providing 50*50mm wel mesh including loading and unloading of pipe for the following category to suit MS Pipe. Tje weight of the MS shell only be considered before lining and coating for arriving at the rate. The thickness of plate will be specified etc with all lead and lift complete & as directed by engineer-in-charge. For upto 500 mm dia

10500

-

1832355

... More
Supply and delivery to work site, loading, unloading, stacking and fixing of Resilient seated soft sealing Sluice Valves with body, bonnet of Ductile Iron of grade GGG40/50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/ DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings (minimum 2 'O' rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS etc with all lead and lift complete & as directed by engineer-in-charge. DI 80mm dia Sluice valve PN 16 (For air valve)

12

-

103832.76

... More
-do- DI 100mm dia Sluice valve PN 16 (For scoure) & air valve - with all lead and lift complete & as directed by engineer-in-charge.

15

-

164438.4

... More
-do- DI 200mm dia Sluice valve PN 16 (For scoure & line) - with all lead and lift complete & as directed by engineer-in-charge.

5

-

152055.3

... More
-do- DI 250mm dia Sluice valve PN 16 (For scoure & line) -with all lead and lift complete & as directed by engineer-in-charge.

5

-

228856

... More
-do- DI 400mm dia Scour valve PN 16 (For line) -with all lead and lift complete & as directed by engineer-in-charge.

2

-

270546.72

... More
-do- DI 450mm dia Scour valve PN 16 (For line) -with all lead and lift complete & as directed by engineer-in-charge.

2

-

369219.2

... More
-do- DI 500mm dia Scour valve PN 16 (For line)-with all lead and lift complete & as directed by engineer-in-charge.

1

-

232818.68

... More
Supply, conveying to work site, loading, unloading, stacking and fixing of single chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/50. All internal parts such as float, shell etc., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside colour bule RAL5005. The valves shall have drain plug of not less than 15 mm nominal pipe thread complete with all lead and lifts. the valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation -with all lead and lift complete & as directed by engineer-in-charge-DI Air Valve 80mm dia PN 16

12

-

305145.96

... More
-do- DI Air Valve 100mm dia PN 16 - with all lead and lift complete & as directed by engineer-in-charge

12

-

460681.44

... More
Supply and delivery of Woltman model with removal mechanism water meters confirming to ISO 4064 part I,II,III class B or IS 779 and IS 2373 with life cycle test certificate from FCRI/ NABL accredited lab. The water meters shall have magnetic drivers or mechanical drivers and shall be versatile for installation in any position. The meters shall be hydrodynamically, hydrostatically balanced. The runner, runner chamber, pointer of the meter shall be as per ISO 4064 class B specification. Dry dial excavated counter housing fully protected against flooding ensuring easy reading in all climates. etc with all lead and lift complete & as directed by engineer-in-charge. Flow meter - 600mm dia

1

-

336407.14

... More
-do- Flow meter - 500mm dia - with all lead and lift complete & as directed by engineer-in-charge

1

-

336407.14

... More
-do- Flow meter - 400mm dia- with all lead and lift complete & as directed by engineer-in-charge

2

-

543490.08

... More
-do- Flow meter - 300mm dia - with all lead and lift complete & as directed by engineer-in-charge

2

-

331372.12

... More
-do- Flow meter - 250mm dia - with all lead and lift complete & as directed by engineer-in-charge

6

-

595898.1

... More
-do- Flow meter - 200mm dia- with all lead and lift complete & as directed by engineer-in-charge

4

-

182708.6

... More
RCC Shaft Wall: - Providing and laying vibrated M 25 design mix for RCC work (Excluding cost of reinforcement) with 20 mm and down size of approved gradation hard broken granite, trap, basalt or any other approved hard aggregate including cost and conveyance of all materials with all lead and lifts including weigh batch plant mixing, plywood/steel form work, centering, scaffolding, curing, plastering & smooth finishing the exposed faces in C.M. 1:3, 12mm thick as per designs etc., complete for RCC Shaft.(Cement 360 kgs) with all lead and lift complete & as directed by engineer-in-charge. For Upto GL and 6 Mtr. height, for OHT's MT & Z-1 to Z-7

575.58

-

8629809.08

... More
-do- Above 6 Mtr. upto 9 Mtr. Height -with all lead and lift complete & as directed by engineer-in-charge.for OHT's MT & Z-1 to Z-7

241.47

-

3738820.06

... More
Providing and laying vibrated M 30 design mix for RCC work (excluding cost of reinforcement) with 20 mm and down size of approved gradation hard broken granite, trap, basalt or any other approved hard aggregate including cost and conveyance of all materials with all lead & lift plywood / steel form work, centering scaffolding, plastering and smooth finishing the exposed faces in CM 1:3 12mm thick and CM plastering 1:3 proportion 20 mm thick for inside with an admixture of water proof compund of requisite proportion of approved quality inculding weigh batch plant mixing, curing etc., and reservoir given satisfactory water proof tesing as per directions, etc., complete for conical shell portion, bottom dome/slab, sidewall and ribs over the staging (Contractor will make his own arrangements or procuring waterfor testing) (cement 400 kgs) with all lead and lift complete & as directed by engineer-in-charge. For Bottom ring beam, Platform - 4, Conical wall of Tank,Middle Ring Beam,Platform - 5 alround,Side wall of Tank, For 10LL-Ohts

330.99

-

6831358.88

... More
Top Dome: - Providing and laying vibrated M 30 design mix for RCC work (excluding cost of reinforcement) with 20 mm and down size of approved gradation hard broken granite, trap, basalt or any other approved hard aggregate including cost and conveyance of all materials with all lead & lift above staging including weigh batch plant mixing, centering, plywood/steel form work, scaffolding, tamping, curing, cement mortar plastering 1:3 proporation 12mm thick for both inside & outside surface etc, complete for Top dome/slab. (cement 400 kgs) with all lead and lift complete & as directed by engineer-in-charge. For Top dome, top Ring Beam,Platform - 6 Alround,

43.11

-

1033615.28

... More
Providing and fixing 1mm thick M.S.Sheet garage door with frame and diagoal bracess of size 40x40x6mm angle iron, 3.15mm thick M.S.gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc including applying a priming coat of red lead plaint cost of materials, labour, HOM of machinery complete as per specifications. Double leaf door of size 2.4 x 2.4 M. with all lead and lift complete & as directed by engineer-in-charge - For Door-All Oht's

33.6

-

98168.11

... More
Providing 2 coats of water proof cement painting of approved quility colure and shade over one coat of primer including scraping faces, with wire brushes etc,. before removal of scaffolding for new RCC Over Head Tanks and cleaning of paint stains where ever necesary with all lead and lift complete & as directed by engineer-in-charge. For TOP DOME, TOP RING BEAM, WALK WAY AT TOP BEAM,WALK WAY AT TOP BEAM SIDE,SIDE WALL,MIDDLE RING BEAM,WALK WAY AT MIDDLE BEAM,WALK WAY AT MIDDLE BEAM SIDE,CONICAL WALL,BOTTOM DOME OUTSIDE,SHAFT INSIDE,SHAFT OUTSIDE,Painting to Landing

1411.74

-

308324.02

... More
RCC Finial :- Providing and fixing R.C.C. finial and ventialators as per approved design and specification with form work and protected with wire mesh. The plinth to be of RCC circular pillars and canopy with an ornamental finish at top. The first 22.50cm height to be covered with RCC panelling as per detailed drawing with all lead and lift complete & as directed by engineer-in-charge. For tanks above 10 LL capacity- For 10LL-oht's

2

-

15348.12

... More
Gauge:- Providing and fixing guage with iron sheet of 3 mm to 4 mm thickness, 0.23 Mtr. width with copper floats indicators and flexible nylon wires, painting figures with approved enamelled paint with all lead and lifts etc., complete. Enamelled gauge plate. 0 to 4.5 Mtr. depth with all lead and lift complete & as directed by engineer-in-charge. For tanks above 10 LL capacity

7

-

72835.14

... More
Lightining Arrester- Supplying and fixing lightening arrestor of aluminium strip 25 mm x 3 mm size including finial and grounding, aluminium strip is to be embeded in one of the columns in an independent GI conduit of 40 mm dia pipe suitably jointed by collars with all specials with all lead and lift complete & as directed by engineer-in-charge. For For tanks above 6 Mtr. upto 9 Mtr. staging

2

-

27474.02

... More
Puddle Flanges:- Supplying & Fixing CI puddle flanges confirming to IS 7181-1986 with latest amendments, in position for RCC walls including hoisting and conveying them to work spot with all lead and lift complete & as directed by engineer-in-charge. CI 600mm dia - Inlet, two-Outlets, one-extra for future use.

3

-

110594.46

... More
-do- CI 250mm dia - Overflow, Washout - with all lead and lift complete & as directed by engineer-in-charge.

11

-

107013.28

... More
CI Pipes - Supplying, laying of CI flanged pipe true to line / hoisting of CI flanged pipe confirming to IS 7181-1986 with latest amendments in position and aligning to correct plumb including cost of jointing material conveying to work spot with all lead and lift complete & as directed by engineer-in-charge. CI 600mm dia - Inlet, two-Outlets, one-extra for future use.

60

-

1592239.8

... More
-do- CI 250mm dia - Overflow, Washout - with all lead and lift complete & as directed by engineer-in-charge.

217.5

-

1508645.25

... More
Supply and delivery to work site, loading, unloading, stacking and fixing of Resilient seated soft sealing Sluice Valves with body, bonnet of Ductile Iron of grade GGG40/50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/ DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings (minimum 2 'O' rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS etc, with all lead and lift complete & as directed by engineer-in-charge. DI Sluice Valve -600 mm dia PN 10

3

-

699085.53

... More
Providing Duck foot bend confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc with all lead and lift complete & as directed by engineer-in-charge. CI 600 mm dia

3

-

54000

... More
-do- CI 250 mm dia - with all lead and lift complete & as directed by engineer-in-charge.

11

-

121000

... More
Supplying & fixing of 5/8x4" size blots and nuts with washers with all lead and lift complete & as directed by engineer-in-charge. For Ohts, Sumps etc

5450

-

599500

... More
Supplying & fixing of 7/8x5" size blots and nuts with washers with washers with all lead and lift complete & as directed by engineer-in-charge.For Ohts, Sumps etc

5450

-

817500

... More
Supplying & fixing of Rubber insertions with all lead and lift complete & as directed by engineer-in-charge.

3000

-

225000

... More
Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220 kgs with 40mm and down size graded granite metal coarse aggregates @ 0.892 cum and fine aggregates @ 0.456cum, machine mixed, concrete laid in layers not exceeding 15cms well compacted in foundation including cost of all materials, labour, HOM of machinery, curing complete as per specifications with all lead and lift complete & as directed by engineer-in-charge. For OHT's

77.33

-

430981.74

... More
Providing and laying in position plain cement concrete of nomninal mix 1:2:4 with OPC cement @ 240 Kgs with 20mm and down size graded granite coarse aggregates @ 0.69 cum and fine aggregate @ 0.459cum, machine mixed, concrete laid in layers not exceeding 15cm thcik well compacted, in foundation, plinth and cills, including cost of all materials, labours, HOM of machinery,curing complete as per specification with all lead and lift complete & as directed by engineer-in-charge. For OHT's

77.33

-

455312.85

... More
-do- Above 9 Mtr. upto 12 Mtr. Height - with all lead and lift complete & as directed by engineer-in-charge, For all Oht's

197.03

-

3147339.49

... More
-do- Above 12 Mtr. upto 15 Mtr. Height - with all lead and lift complete & as directed by engineer-in-charge For all Oht's

85.85

-

1413455.86

... More
Providing and laying vibrated M 30 design mix for RCC work (excluding cost of reinforcement) with 20 mm and down size of approved gradation hard broken granite, trap, basalt or any other approved hard aggregate including cost and conveyance of all materials with all lead & lift plywood / steel form work, centering scaffolding, plastering and smooth finishing the exposed faces in CM 1:3 12mm thick and CM plastering 1:3 proportion 20 mm thick for inside with an admixture of water proof compund of requisite proportion of approved quality inculding weigh batch plant mixing, curing etc., and reservoir given satisfactory water proof tesing as per directions, etc., complete for conical shell portion, bottom dome/slab, sidewall and ribs over the staging (Contractor will make his own arrangements or procuring waterfor testing) (cement 400 kgs) with all lead and lift complete & as directed by engineer-in-charge. For Bottom ring beam, Platform - 4, Conical wall of Tank,Middle Ring Beam,Platform - 5 alround,Side wall of Tank, for 15LL all Oht's

1653.72

-

43922125.17

... More
Top Dome :- Providing and laying vibrated M 30 design mix for RCC work (excluding cost of reinforcement) with 20 mm and down size of approved gradation hard broken granite, trap, basalt or any other approved hard aggregate including cost and conveyance of all materials with all lead & lift above staging including weigh batch plant mixing, centering, plywood/steel form work, scaffolding, tamping, curing, cement mortar plastering 1:3 proporation 12mm thick for both inside & outside surface etc, complete for Top dome/slab. (cement 400 kgs) with all lead and lift complete & as directed by engineer-in-charge. For Top dome, top Ring Beam,Platform - 6 Alround,

423.9

-

12537495.31

... More
Providing 2 coats of water proof cement painting of approved quility colure and shade over one coat of primer including scraping faces, with wire brushes etc,. before removal of scaffolding for new RCC Over Head Tanks and cleaning of paint stains where ever necesary with all lead and lift complete & as directed by engineer-in-charge. For TOP DOME, TOP RING BEAM, WALK WAY AT TOP BEAM,WALK WAY AT TOP BEAM SIDE,SIDE WALL,MIDDLE RING BEAM,WALK WAY AT MIDDLE BEAM,WALK WAY AT MIDDLE BEAM SIDE,CONICAL WALL,BOTTOM DOME OUTSIDE,SHAFT INSIDE,SHAFT OUTSIDE,Painting to Landing, For 15LL-all Oht's

13894.03

-

3584798.68

... More
RCC Finial :- Providing and fixing R.C.C. finial and ventialators as per approved design and specification with form work and protected with wire mesh. The plinth to be of RCC circular pillars and canopy with an ornamental finish at top. The first 22.50cm height to be covered with RCC panelling as per detailed drawing with all lead and lift complete & as directed by engineer-in-charge. For tanks above 10 LL capacity.

6

-

69066.54

... More
Lightining Arrester:- Supplying and fixing lightening arrestor of aluminium strip 25 mm x 3 mm size including finial and grounding, aluminium strip is to be embeded in one of the columns in an independent GI conduit of 40 mm dia pipe suitably jointed by collars with all specials with all lead and lift complete & as directed by engineer-in-charge. For For tanks above 6 Mtr. upto 9 Mtr. staging

3

-

86604.96

... More
Puddle Flanges:- Supplying & Fixing CI puddle flanges confirming to IS 7181-1986 with latest amendments, in position for RCC walls including hoisting and conveying them to work spot with all lead and lift complete & as directed by engineer-in-charge. CI 300mm dia - two-Outlets, one-extra for future use.for 15LL-all oht's

12

-

150691.32

... More
-do- CI 200mm dia - Washout - with all lead and lift complete & as directed by engineer-in-charge.

14

-

105175.56

... More
CI Pipes:- Supplying, laying of CI flanged pipe true to line / hoisting of CI flanged pipe confirming to IS 7181-1986 with latest amendments in position and aligning to correct plumb including cost of jointing material conveying to work spot with all lead and lift complete & as directed by engineer-in-charge. CI 300mm dia - two-Outlets, one-extra for future use.

216

-

1905269.04

... More
-do- CI 200mm dia - Washout - with all lead and lift complete & as directed by engineer-in-charge.

259

-

1355199.37

... More
Supply and delivery to work site, loading, unloading, stacking and fixing of Resilient seated soft sealing Sluice Valves with body, bonnet of Ductile Iron of grade GGG40/50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/ DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings (minimum 2 'O' rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS etc, with all lead and lift complete & as directed by engineer-in-charge. DI Sluice Valve -300 mm dia PN 10

19

-

1225835.35

... More
-do- DI Sluice Valve -200 mm dia PN 10- with all lead and lift complete & as directed by engineer-in-charge.

6

-

182466.36

... More
Providing Duck foot bend confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc with all lead and lift complete & as directed by engineer-in-charge. CI 300 mm dia

12

-

180000

... More
-do- CI 200 mm dia - with all lead and lift complete & as directed by engineer-in-charge.

14

-

133000

... More
Supply and delivery to work site, loading, unloading, stacking and fixing of Resilient seated soft sealing Sluice Valves with body, bonnet of Ductile Iron of grade GGG40/50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/ DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings (minimum 2 'O' rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS etc, with all lead and lift complete & as directed by engineer-in-charge. DI Sluice Valve -450 mm dia PN 10

1

-

184609.6

... More
Lightining Arrester:- Supplying and fixing lightening arrestor of aluminium strip 25 mm x 3 mm size including finial and grounding, aluminium strip is to be embeded in one of the columns in an independent GI conduit of 40 mm dia pipe suitably jointed by collars with all specials with all lead and lift complete & as directed by engineer-in-charge. For For tanks above 6 Mtr. upto 9 Mtr. staging

2

-

32980.54

... More
Lightining Arrester- Supplying and fixing lightening arrestor of aluminium strip 25 mm x 3 mm size including finial and grounding, aluminium strip is to be embeded in one of the columns in an independent GI conduit of 40 mm dia pipe suitably jointed by collars with all specials with all lead and lift complete & as directed by engineer-in-charge. For For tanks above 6 Mtr. upto 9 Mtr. staging

1

-

19245.55

... More
-do- DI Sluice Valve -200 mm dia PN 10- with all lead and lift complete & as directed by engineer-in-charge.

18

-

547399.08

... More
Gauge- Providing and fixing guage with iron sheet of 3 mm to 4 mm thickness, 0.23 Mtr. width with copper floats indicators and flexible nylon wires, painting figures with approved enamelled paint with all lead and lifts etc., complete. Enamelled gauge plate. 0 to 3.5 Mtr. depth with all lead and lift complete & as directed by engineer-in-charge.For Sump-1.6LL

1

-

6583.18

... More
Puddle Flanges - Supplying & Fixing CI puddle flanges confirming to IS 7181-1986 with latest amendments, in position for RCC walls including hoisting and conveying them to work spot with all lead and lift complete & as directed by engineer-in-charge. For 150mm dia - Inlet, two Outlets future extra, Overflow, Washout, For Sump-1.6LL

5

-

24729.85

... More
Providing all Electrification works to Pumphouse with complete all lead and for all lifts complete & as directed by engineer-in-charge. For PH at IPS

1

-

37630

... More
Manufacturing, providing, transporting, rolling, lowering, laying & Jointing, testing, commissioning of ERW (Electric Resisance Welded)/SAW (Sub-merged Arc Welded) MS pipes (Fe-410 grade) conforiming to IS 3589-2001 with latest amendments including perfect linking and welding of joints to correct position including cost and conveyance of pipes and materials with all lead and lift, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both a factory and sit etc complete as per detailed specifications. With inside CM 1:1.5 lining of minium 10mm thick upto 610mm OD & minimum 12 mm thick beyond 610mm OD and outside minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangement for procuring water for testing) etc Complete with all lead and lift complete & as directed by engineer-in-charge. For MS 273.10 mm dia - 5.6mm thick

100

-

371280

... More
Supplying HDPE pipes conforming to IS 4984:1995 with latest amendments and conveying to work site including loading and unloading at both destination and rolling, lowering into trenches, laying true to line and jointing of pipes and specials by electrofusion welding, as per standerd procedure and guide lines including encasing the pipe around to a depth not less than 15cms with cleaned soft gravel or selected earth available from the excavation etc., complete giving hydraulic test as per relevant IS Specification with all lead and lift including , testing and commissioning. The rate is inclusive of required specials and fittings, Ms flanges with nuts and bolts etc, complete (Contractor will make his own arrangement for procuring water for testing) Upto 110mm dia,Coils shall be used etc with all lead and lift complete & as directed by engineer-in-charge. For HDPE PE-100 PN 8-75mm dia

50968

-

10775654.56

... More
-do- For HDPE PE-100 PN 8-90mm dia -- with all lead and lift complete & as directed by engineer-in-charge.

11849

-

3321393.19

... More
-do- For HDPE PE-100 PN 8-110mm dia -- with all lead and lift complete & as directed by engineer-in-charge.

7902

-

3081621.96

... More
-do- For HDPE PE-100 PN 8-125mm dia -- with all lead and lift complete & as directed by engineer-in-charge.

7308

-

3548253.24

... More
-do- For HDPE PE-100 PN 8-140mm dia -- with all lead and lift complete & as directed by engineer-in-charge.

4616

-

2818760.4

... More
-do- For HDPE PE-100 PN 8-160mm dia -- with all lead and lift complete & as directed by engineer-in-charge.

5620

-

4262264.2

... More
-do- For HDPE PE-100 PN 8-180mm dia -- with all lead and lift complete & as directed by engineer-in-charge.

3524

-

3291239.8

... More
-do- For HDPE PE-100 PN 8-200mm dia -- with all lead and lift complete & as directed by engineer-in-charge.

4514

-

5172908.58

... More
-do- For HDPE PE-100 PN 8 - For Rider lines of 75mm dia HDPE pipe proposed parallel to 200 to 400 mm dia pipe line- with all lead and lift complete & as directed by engineer-in-charge.

15533

-

3283986.86

... More
Supplying,laying,jointing ,testing and commissioning of G.I. Pipes conforming to IS 1239:1990 with latest amendments, including fixing Collars, Elbows, Tees, bends, Glad Cocks and other Fittings (Excluding Cost of Specials) with Cuts and Threads wherever necessary including conveying the materials to workspot, including testing for water tightness with all lead and lifts etc complete (Contractor shall make his own arrangements for procuring water for testing) with all lead and lift complete & as directed by engineer-in-charge. For GI - 80mm dia Pipe - Heavy duty

7611

-

5301518.16

... More
-do- GI 100mm dia Pipe - Heavy duty - with all lead and lift complete & as directed by engineer-in-charge.

7611

-

7549959.78

... More
Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments etc with all lead and lift complete & as directed by engineer-in-charge.For GI 80mm dia Heavy duty Collars

1903

-

560281.26

... More
-do- GI 100mm dia Pipe - Heavy duty Collars- with all lead and lift complete & as directed by engineer-in-charge.

1903

-

702892.08

... More
Providing wrought mild steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments etc with all lead and lift complete & as directed by engineer-in-charge.For GI 80mm dia Heavy duty Union

700

-

296023

... More
-do- GI 100mm dia Pipe - Heavy duty Union- with all lead and lift complete & as directed by engineer-in-charge.

700

-

318500

... More
Providing wrought mild steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any etc with all lead and lift complete & as directed by engineer-in-charge.For GI 80mm dia Heavy duty Elbow

500

-

152560

... More
-do- GI 100mm dia Pipe - Heavy duty Elbow- with all lead and lift complete & as directed by engineer-in-charge.

500

-

179325

... More
Providing wrought mild steel (galvanized) GI bend confirming to IS 1239-II, 1991 with latest amendments if any etc with all lead and lift complete & as directed by engineer-in-charge.For GI 80mm dia Heavy duty Bend

600

-

215190

... More
-do- GI 100mm dia Pipe - Heavy duty Bend- with all lead and lift complete & as directed by engineer-in-charge.

600

-

263370

... More
Providing wrought mild steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any etc with all lead and lift complete & as directed by engineer-in-charge.For GI 80mm dia Heavy duty Tee

650

-

206680.5

... More
-do- GI 100mm dia Pipe - Heavy duty Tee- with all lead and lift complete & as directed by engineer-in-charge.

650

-

288795

... More
Providing wrought mild steel (galvanized) GI socket confirming to IS 1239-II, 1991 with latest amendments if any with all lead and lift complete & as directed by engineer-in-charge.For GI 80mm dia Heavy duty Socket

500

-

165945

... More
-do- GI 100mm dia Pipe - Heavy duty Socket- with all lead and lift complete & as directed by engineer-in-charge.

500

-

206090

... More
Supplying DI pipes conforming to IS 8329:2000 with latest amendments and conveying to work site, rolling and lowering into trenches,laying true to line,level and perfect linking at joints,testing and commissioning including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of DI pipes and specials,(excluding cost of special) with rubber gaskets including cleaning of socket and spigot ends with soap solution and applying soft soap to the spigot and socket ends before insertion of rubber gaskets,jacking and fixing in perfect condition including cost of soap solution,soft soap, waste etc.,and giving necessary hydraulic tests to the required pressure as per IS Specification with all lead and lift including cost of jointing material. (Contractor will make his own arrangement for procuring water for testing) with all lead and lift complete & as directed by engineer-in-charge.DI 200mm dia K7 Class Pipes

5668

-

10585273.4

... More
-do- DI 250mm dia K7 Class Pipes- with all lead and lift complete & as directed by engineer-in-charge.

5095

-

12388900.1

... More
-do- DI 300mm dia K7 Class Pipes- with all lead and lift complete & as directed by engineer-in-charge.

3563

-

10971082.71

... More
-do- DI 350mm dia K7 Class Pipes- with all lead and lift complete & as directed by engineer-in-charge.

272

-

1042442.72

... More
Supply and delivery to work site, loading, unloading, stacking and fixing of Resilient seated soft sealing Sluice Valves with body, bonnet of Ductile Iron of grade GGG40/50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face dimensions as per BS 5163-89/IS 14846-2000/ DIN 3202 F4/F5. The stem sealing should be with Toroidal sealing rings (minimum 2 'O' rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers as per relevant IS etc with all lead and lift complete & as directed by engineer-in-charge. DI Sluice Valve 50mm dia PN 10

25

-

147046.5

... More
-do-DI Sluice Valve 80mm dia PN 10- with all lead and lift complete & as directed by engineer-in-charge.

105

-

908536.65

... More
-do-DI Sluice Valve 100mm dia PN 10- with all lead and lift complete & as directed by engineer-in-charge.

90

-

986630.4

... More
Supply, conveying to work site, loading, unloading, stacking and fixing of single chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/50. All internal parts such as float, shell etc., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside colour bule RAL5005. The valves shall have drain plug of not less than 15 mm nominal pipe thread complete with all lead and lifts. the valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation with all lead and lift complete & as directed by engineer-in-charge. DI Air Valve 50mm dia PN 10

25

-

413535

... More
-do-DI Air Valve 80mm dia PN 10- with all lead and lift complete & as directed by engineer-in-charge.

25

-

581029.25

... More
Providing and laying reinforeced cement concrete pipe NP 3 for culvert incluiding pointing ends , and fixing collars with cement mortor 1:2 incluiding cost of all materials, labour, curing completewith all lead and lift complete & as directed by engineer-in-charge. RCC 300mm NP-3 Pipes

500

-

820080

... More
PROVIDING HOUSE SERVICE CONNECTIONS - DOMESTIC HSC - Supply and installation of water connections to individual houses upto water meter point (which shall be fixed about one meter from customer boundary) and includes civil works like Earthwork excavation for the pipeline trenches for laying of MDPE/GI pipes for the house connections in all types of soils, disintegrated rock, soft rock, hard rock, including cutting of any road using machine cutter, crossing drains, compound, cutting any surfaces along the pipelines such as tiles/floor/concrete/ or any other surfaces using machine cutter, boring the wall surfaces comprising of BBM or SSM for conveying the pipelines to customer property, restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open etc. complete. Supply and laying of MDPE PE-80, PN 12.5 pipes with specials such as Electrofusion tapping Tee or saddles Virgin compounded PE 100 material, black colour of pressure rating PN 16 / SDR 11 or higher grade of approved make conforming to standard specification with brass cutter, flow regulator, water tight cap with “O” ring, long spigot, cutting edges for making hole / tipping suitable to HDPE distribution mains by electrofusion welding as per BS EN 12201 – 3 & EN 1555-3 Standards. The product should be treated to comply with BS 6920 for drinking water service in WRC – NSF, UK and DVGW certificate, Germany, Tapping Tee or Saddles with coupler and compression fitting with cost of GI pipes all specials such as GI tee, GI elbow, GI coupler, stopper etc and brass or SS tap (as shown in Fig No. 2.1, 2.2 & 2.3 in BOARD SR) for the following diameters with all lead and lift etc with all lead and lift complete & as directed by engineer-in-charge. DOMESTIC HSC - Supplying and fixing of multijet class B inferential type, AMR compatable water meters with IP 68 protection totalizer conforming to IS 779 with its latest amendments of following size to servicw connection incluiding conveying and fixing of necessary GI specials etc with all lead and lift complete & as directed by engineer-in-charge. DOMESTIC HSC - Supplying and fixing of HDPE Water box with locking arrangements to protect the Water meter of class "B" Multijet type of size 15 to 32 mm including HDPE box with base dia 300mm x lid dia 200mm X Height 250mm with openable lid and the cover is buried below GL with lid flush with GL including earth work excavation for 600mm X 600mm and base sand filling for 100mm thick over which the cover is placed and enclosed by PCC 1:2:4 using 12-20mm BG jelly for an height of 150mm and refilling with excavated earth for balance 100mm height, disposal of excess earth (as per drawing enclosed) etc with all lead and lift complete & as directed by engineer-in-charge. For 15mm dia connection

6750

-

57537000

... More
PROVIDING HOUSE SERVICE CONNECTIONS - NON-DOMESTIC HSC - Supply and installation of water connections to individual houses upto water meter point (which shall be fixed about one meter from customer boundary) and includes civil works like Earthwork excavation for the pipeline trenches for laying of MDPE/GI pipes for the house connections in all types of soils, disintegrated rock, soft rock, hard rock, including cutting of any road using machine cutter, crossing drains, compound, cutting any surfaces along the pipelines such as tiles/floor/concrete/ or any other surfaces using machine cutter, boring the wall surfaces comprising of BBM or SSM for conveying the pipelines to customer property, restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open etc. complete. Supply and laying of MDPE PE-80, PN 12.5 pipes with specials such as Electrofusion tapping Tee or saddles Virgin compounded PE 100 material, black colour of pressure rating PN 16 / SDR 11 or higher grade of approved make conforming to standard specification with brass cutter, flow regulator, water tight cap with “O” ring, long spigot, cutting edges for making hole / tipping suitable to HDPE distribution mains by electrofusion welding as per BS EN 12201 – 3 & EN 1555-3 Standards. The product should be treated to comply with BS 6920 for drinking water service in WRC – NSF, UK and DVGW certificate, Germany, Tapping Tee or Saddles with coupler and compression fitting with cost of GI pipes all specials such as GI tee, GI elbow, GI coupler, stopper etc and brass or SS tap (as shown in Fig No. 2.1, 2.2 & 2.3) with all lead and lift etc with all lead and lift complete & as directed by engineer-in-charge. NON-DOMESTIC HSC - Supplying and fixing of multijet class B inferential type, AMR compatable water meters with IP 68 protection totalizer conforming to IS 779 with its latest amendments of following size to servicw connection incluiding conveying and fixing of necessary GI specials etc with all lead and lift complete & as directed by engineer-in-charge. NON-DOMESTIC HSC - Supplying and fixing of HDPE Water box with locking arrangements to protect the Water meter of class "B" Multijet type of size 15 to 32 mm including HDPE box with base dia 300mm x lid dia 200mm X Height 250mm with openable lid and the cover is buried below GL with lid flush with GL including earth work excavation for 600mm X 600mm and base sand filling for 100mm thick over which the cover is placed and enclosed by PCC 1:2:4 using 12-20mm BG jelly for an height of 150mm and refilling with excavated earth for balance 100mm height, disposal of excess earth (as per drawing enclosed) etc with all lead and lift complete & as directed by engineer-in-charge. For 20mm dia connection

327

-

3204273

... More
PROVIDING HOUSE SERVICE CONNECTIONS - COMMERCIAL-HSC - Supply and installation of water connections to individual houses upto water meter point (which shall be fixed about one meter from customer boundary) and includes civil works like Earthwork excavation for the pipeline trenches for laying of MDPE/GI pipes for the house connections in all types of soils, disintegrated rock, soft rock, hard rock, including cutting of any road using machine cutter, crossing drains, compound, cutting any surfaces along the pipelines such as tiles/floor/concrete/ or any other surfaces using machine cutter, boring the wall surfaces comprising of BBM or SSM for conveying the pipelines to customer property, restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open etc. complete. Supply and laying of MDPE PE-80, PN 12.5 pipes with specials such as Electrofusion tapping Tee or saddles Virgin compounded PE 100 material, black colour of pressure rating PN 16 / SDR 11 or higher grade of approved make conforming to standard specification with brass cutter, flow regulator, water tight cap with “O” ring, long spigot, cutting edges for making hole / tipping suitable to HDPE distribution mains by electrofusion welding as per BS EN 12201 – 3 & EN 1555-3 Standards. The product should be treated to comply with BS 6920 for drinking water service in WRC – NSF, UK and DVGW certificate, Germany, Tapping Tee or Saddles with coupler and compression fitting with cost of GI pipes all specials such as GI tee, GI elbow, GI coupler, stopper etc and brass or SS tap (as shown in Fig No. 2.1, 2.2 & 2.3) with all lead and lift etc with all lead and lift complete & as directed by engineer-in-charge. COMMERCIAL HSC - Supplying and fixing of multijet class B inferential type, AMR compatable water meters with IP 68 protection totalizer conforming to IS 779 with its latest amendments of following size to servicw connection incluiding conveying and fixing of necessary GI specials etc with all lead and lift complete & as directed by engineer-in-charge. COMMERCIAL HSC - Supplying and fixing of HDPE Water box with locking arrangements to protect the Water meter of class "B" Multijet type of size 15 to 32 mm including HDPE box with base dia 300mm x lid dia 200mm X Height 250mm with openable lid and the cover is buried below GL with lid flush with GL including earth work excavation for 600mm X 600mm and base sand filling for 100mm thick over which the cover is placed and enclosed by PCC 1:2:4 using 12-20mm BG jelly for an height of 150mm and refilling with excavated earth for balance 100mm height, disposal of excess earth (as per drawing enclosed) etc with all lead and lift complete & as directed by engineer-in-charge. For 25mm dia connection

664

-

8750192

... More
PROVIDING HOUSE SERVICE CONNECTIONS - DOMESTIC-WITH GI PIPE- HSC - at Hillock : - Supply and installation of water connections to individual houses upto water meter point (which shall be fixed about one meter from customer boundary) and includes civil works like Earthwork excavation for the pipeline trenches for laying of GI pipes for the house connections in all types of soils, disintegrated rock, soft rock, hard rock, including cutting of any road using machine cutter, crossing drains, compound, cutting any surfaces along the pipelines such as tiles/floor/concrete/ or any other surfaces using machine cutter, boring the wall surfaces comprising of BBM or SSM for conveying the pipelines to customer property, restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open etc. complete. Supply and laying of 15 mm dia GI pipe of Medium Duty with specials such as 65x65x15 mm dia G.I Pipe tapping tee of Heavy Duty conforming to standard specification with brass cutter, flow regulator, cutting edges for making hole / tipping suitable to GI distribution mains by threading & Plumbing as per IS 1239 with latest amendments Standards with required numbers of 15mm dia GI Nipple, GI elbows, GI Collar, GI Union, GI Coupler, Brass ferrule ,as per the drawing enclosed with a CC block of required size and with brass or SS tap (as shown in Fig) The product should be treated to comply with BS 6920 for drinking water service in WRC – NSF, UK and DVGW certificate, Germany, Tapping Tee or Saddles with coupler etc with all lead and lift complete & as directed by engineer-in-charge. DOMESTIC-WITH GI PIPE- HSC - :- Supplying and fixing multijet class B inferential type, AMR compatable water meters with IP 68 protection totalizer confirming to IS 779 with its latest amendments of following size to service connections including conveying and fixing of necessary G.I specials etc with all lead and lift complete & as directed by engineer-in-charge. DOMESTIC-WITH GI PIPE- HSC :- Supply and fixing of HDPE water meter box to protect the water meter of Class ‘B’ Multijet type of size 15 to 32 mm including HDPE box with base dia 300mm x lid dia 200mm x height 250mm with openable lid and the cover is buried below GL with lid flush with GL including earth work excavation for 600mm x 600mm and base sand filling for 100mm thick over which the cover is placed and enclosed by PCC 1:3:6 using 12-20mm BG jelly for an height of 150mm and refilling with excavated earth for balance 100mm height, disposal of excess earth (as per drawing enclosed) etc with all lead and lift complete & as directed by engineer-in-charge. For 15mm dia- upto & above 10mt length

1417

-

9098557

... More
Construction of 13 MLD capacity Micro Screen Filtration Plant : Dismantling and demolition of defunct WTP including all components, along with cutting of trees, jungle clearing etc if any with all lead and lift complete & as directed by engineer-in-charge

1

-

857143

... More
AERATOR Adequate aeration system need to be incorporated to aerate water before it enters the filtration unit. The aerator shall be of cascade type, rectangular or circular in structure with minimum 4 steps & a collecting channel around, duly constructed to ensure nappe flow of cascade. It shall be designed to ensure maximum aeration efficiency in accordance with site conditions prevailing year round. Structure shall be of RCC with M30 concrete mix and designed for a contact area of 715 m3/hr flow of water. The minimum thickness of M30 concrete for the trays shall be 150mm and minimum thickness of M30 proportion for the steining of the inlet well and the footing shall be 150mm. Both the surfaces of the concrete are to be plastered with C.M. 1:3, 12mm thick with admixer of water W.P.C in requisite proportion for plastering to water surfaces.The steps and walkway surface shall be finished smooth with coat of approved colour to be decided by etc if any with all lead and lift complete & as directed by engineer-in-charge.

1

-

957963

... More
RAW WATER CHANNEL & BY-PASS CHANNEL ARRANGEMENT There shall be a raw water channel from the Aerator to flash mixer to carry 715 m3/hr of water. A venturiflume/weir shall be provided in the raw water channel with necessary accessories to measure the flow of raw water entering the Flash mixer. The venturiflume/v-notch/weir shall be suitably designed to indicate or measure the actual flow. The raw water channel shall be of RCC M30 proportion mix with a minimum concrete thickness of 150mm for walls and floor. The internal surface of the raw water channel shall be finished with smooth and straight with coat of approved colour to be decided by the Engineer-in-charge. The surfaces of the concrete are to be plastered with cement mortar 1:3, 12 mm thick with admixture of water proof compound in requisite proportion for plastering to water surfaces suitable to carry with bypass arrangement channels with required lengths and numbers etc if any with all lead and lift complete & as directed by engineer-in-charge.

1

-

327420

... More
FLASH MIXER: The flash mixer shall be for the capacity of 13 ML in 20 Hrs. Provisions shall be made for an outlet of 13 ML in 20 Hrs. to connect the Lamella settler. The flash mixer should be designed for a detention period of 30 seconds. The flash mixer chamber shall be of RCC circular type minimum 1.8m dia and to be constructed with M30 proportion concrete mix. The minimum thickness of concrete of 150mm shall be provided to both wall and foundation of the flash mixer. Both the surfaces of concrete are to be plastered with CM 1:3 with 12mm thick with admixture of compound in requisite proportion for plastering for water faces. A platform of 1.20 Mtr width shall be provided so as to seat the motor and gear box assembly. Suitable HP TEFC motor with starter and all accessories with GI hood cover shall be provided. A suitable worm reduction Gear box for the requirement with necessary couplings including V-Pulley, drive arrangements shall be provided. The paddles shall be with MS radial type turbine paddles with necessary top and bottom bearings assembly with SS shaft and MS base frame, including brass insertions, channels etc necessary anti-corrosive paint shall be provided to all the MS parts etc if any with all lead and lift complete & as directed by engineer-in-charge.

1

-

396163

... More
Lamella Plate Settler Water from floculator enters the Lamella settler from the top. Lamella settler shall have 2 units one for equalising chamber & other lamella plates chamber. The water exits from the bottom in the equalising tank & raises over the plate in the lamella plate chamber. The tank shall be constructed with M30 proportion concrete mix conforming to IS456:2000 and 3370. The minimum thickness of concrete wall should be 200mm. System shall be designed for the flow rate of 876 m3/hr flowrates, along with all necessary accessories such as SS frame for Plates, Sludge Pit, connecting pipe line for sludge pit, sluice valve, interconnecting piping, etc. complete in all respects for adequate performance of clarification system with all lead and lift.etc complete as directed by the engineer incharge. Plate Settler Type of Plates: Flat Deg. Of inclination: 55 Tank MOC: Civil M30 Plates MOC: FRP (Isopthalic) etc if any with all lead and lift complete & as directed by engineer-in-charge.

1

-

13846000

... More
INTERMEDIATE SUMP: Construction of 225 m3 intermediate tank to hold the outlet of lamella settler water for a minimum period of 15 minutes. The tank shall be circular in shape constructed to collect water from the outlet of lamella settler, and shall be constructed with M30 proportion concrete mix conforming to IS456:2000 and 3370. The minimum thickness of concrete wall should be 200mm. The exposed surface shall be painted with WPC painting of approved colour and shade over one coat of primer, with all lead and lift complete as per specification etc if any with all lead and lift complete & as directed by engineer-in-charge.

1

-

2695000

... More
FEED PUMPING SYSTEM: Providing and fixing commissioning of Centrifugal Pumpset of for total flow of 670 m3/hr capacity (100% x 2 nos.) with 15 MWC head, as per IS: 1520-1660, IS-9079, IS: 325 for as per vendor design and process requirement, along with all necessary accessories such as ELCB, MCB, electrical wiring from MCB to motors, suction and delivery header piping along with necessary flow control valves, check valves etc. complete in all respect. (50% x 3 nos.) Casing: Cast iron as per IS: 210: Back pull out type/double suction/Horizontal split casing. Impeller: CF8M Impeller Ring: CF8M Shaft: High Tensile steel –EN8 or SS 410 Shaft Sleeve: SS/Bronze Bearings: Heavy duty Ball/Roller Bearing Drive Motor: IEC 60034 / IS 12615 Base Plate: Cast Iron with all lead and lift.etc complete as directed by the engineer incharge. Impeller shall be made in single piece and shall be securely keyed to the shaft. Measure is to prevent loosening during operation including the rotation in the reverse direction shall be provided. Replaceable shaft sleeves shall be provided the shaft where it passes through the stuffing box. Pump shall be provided with flexible coupling. Common base plate shall be provided for pump and motor. Suitable holes shall be provided grouting and these shall be so located that the base can be grouted in place without disturbing the pump and the motor etc if any with all lead and lift complete & as directed by engineer-in-charge.

2

-

2093000

... More
ACTIVE MEDIA FILTERS: Providing and fixing commissioning of active media filter vessel battery for 670 cu.m/h flow rate as under specification: Vessel Specifications: M.O.C.: Carbon Steel IS 2062 Type: Down flow Max. Filtration Velocity: 16.0 m/hr per vessel Backwash Flow: 40 to 50 m3/hr Internal Diameter: 1600mm Height on straight: 1500 mm Bed depth: 600 mm Vessel Thickness: As per IS 2825 Max. Pressure drop: 0.5 bar. Feed pressure: 1.5 bar Design pressure: 6.0 bar Media (Type & Depth): a) Bottom Layer Gravel : 150 mm b) Top Layer Active Media : 450 mm Media Specifications: Active Media Grade:0.4 – 1.0 mm Type: Activated Media Density: 1.25 gm/cm3 Specific Weight Specific Weight: 1250 kg/m3 Roundness: Greater than 0.6 Coeff. Of Uniformity:1.5 – 1.7 Cross Sectional Ratio: 2.4 Specific Gravity: 2.5 etc if any with all lead and lift complete & as directed by engineer-in-charge.

24

-

38220000

... More
3-WAY FLOW CONTROL VALVES : Providing and fixing commissioning of high quality, hydraulically actuated, 3-way flow control valves for flow regulation during filtration & backwashing modes of active media filters. Complete with all necessary accessories such as PU tubings, PU connectors, Victaulic coupling connectors etc. These should be diaphragm actuated, compact 3 port valves. The diaphragm actuator plug assembly keeps the supply port closed while the opening of the backwash port and vice versa. Size: 3"X3", Double Chambered type with dynamic seal Flow Pattern: Angle/Globe Control Chamber Displacement Volume: 0.34-1.055 litres Operating Pressure: 0.7 - 10 bar Max. Temperature: 65 degrees Celsius End Connection: Grooved Material of Construction Body, Partition Wall & Lower Adaptor: Polyamide 6 – 30GF Diaphragm: NR-AL52 Nylon fabric reinforced Seats, Diaphragm Washer: Brass Plu, Plug Washer: Acetal copolymer Stopper Disc: PVC-U Spring: Stainless steel AISI 302 Shaft: Stainless steel – AISI 303 Seals, O Rings: NBR External bolts, studs, nuts & disks: Stainless Steel with all lead and lift.etc complete etc if any with all lead and lift complete & as directed by engineer-in-charge.

48

-

1646400

... More
ISOLATION VALVES : 80 NB Providing and fixing of Butterfly valves for isolation and flow control in Active Media Filter. The isolation valves shall confirm to the following specifications. Size: 3" Valve type: Butterfly Construction: Wafer type Design std: API609 CAT A Testing std: API 598 Pressure rating: PN10 Flange std: ANSI B 16.5 150# Material of Construction Body: Cast Iron Disc: SGI Seat: EPDM Shaft: SS 410 Operator: Lever with all lead and lift.etc etc if any with all lead and lift complete & as directed by engineer-in-charge.

24

-

137760

... More
SLUICE VALVES : 400 NB Supply,delivery to worksite,loading,unloading,stacking and fixing of Resilient seated soft sealing Sluice Valves with body,bonnet of ductile iron of minimum grade GGG40,wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vaccum tight and 100% leak proof with face dimentions as per BS 5163-89/IS 14846-2000 / DIN 3202 F4/F5.The stem sealing rings(minimum 2 " O" rings).All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage.The valves shall be supplied with suitable size galvanized bolts and nuts of required numbers,etc.complete with all lead and lifts. 400mm dia DI SLV PN-10 Sluice Valves etc if any with all lead and lift complete & as directed by engineer-in-charge.

3

-

346500

... More
ISOLATION VALVES : 400 NB Providing and fixing of Butterfly valves for isolation at Pump discharge piping manifoldsThe isolation valves shall confirm to the following specifications. Size: 16" Valve type: Butterfly Construction: Wafer type Design std: API609 CAT A Testing std: API 598 Pressure rating: PN10 Flange std: ANSI B 16.5 150# Material of Construction Body: Cast Iron Disc: SGI Seat: EPDM Shaft: SS 410 Operator: Lever with all lead and lift.etc complete as directed by the engineer incharge.

2

-

78400

... More
ISOLATION VALVES : 100 NB Providing and fixing of Butterfly valves for isolation and flow control in Security FIlter manifolds. The isolation valves shall confirm to the following specifications. Size: 4" Valve type: Butterfly Construction: Wafer type Design std: API609 CAT A Testing std: API 598 Pressure rating: PN16 Flange std: ANSI B 16.5 150# Material of Construction Body: Cast Iron Disc: SGI Seat: EPDM Shaft: SS 410 Operator: Lever with all lead and lift.etc complete as directed by the engineer incharge.

24

-

216720

... More
MICRO SCREEN FILTER Providing and fixing of online self-cleaning screen type Micro Screen Filter for total flow of 670 cu.m/hr flow rate , as per following specifications: Flow per filter: 168 m3/hr Filtration Degree: 7 micron Design Pressure: 6 bar Design Differential Pressure at 50% clogged condition:0.5 bar Cleaning mechanism: Suction scanner type Operating Voltage: 230 VAC Control Voltage: 24 VAC/24 VDC MOC - Housing & Lid: CS IS 2062 Epoxy Coated MOC - Screen: SS 316 Seals & Gaskets: NBR Max. water rejection: 0.7% of service flow with all lead and lift.etc etc if any with all lead and lift complete & as directed by engineer-in-charge.

4

-

7980000

... More
ISOLATION VALVES : 200 NB : Providing and fixing of Butterfly valves for isolation and flow control in Active Media Filter. The isolation valves shall confirm to the following specifications. Size: 8" Valve type: Butterfly Construction: Wafer type Design std: API609 CAT A Testing std: API 598 Pressure rating: PN10 Flange std: ANSI B 16.5 150# Material of Construction Body: Cast Iron Disc: SGI Seat: EPDM Shaft: SS 410 Operator: Lever with all lead and lift.etc complete etc if any with all lead and lift complete & as directed by engineer-in-charge.

8

-

148400

... More
NON RETURN VALVES (CHECK VALVES): 200 NB Providing and fixing commissioning of high quality non return valves (check valves) at feed pump delivery header. The non-return valves shall confirm to the following specifications: Size: 8" Valve type:Check Valve Construction: Wafer type Design std: API 6D Pressure rating: PN10 Flange std: ANSI B 16.5 150# Material of Construction Body: Mild Steel Disc: Carbon Steel Seat: EPDM Operator: Self - with all lead and lift.etc complete as directed by the engineer incharge.

4

-

67760

... More
NON RETURN VALVES (CHECK VALVES): 400 NB Providing and fixing commissioning of high quality non return valves (check valves) at feed pump delivery header. The non-return valves shall confirm to the following specifications: Size: 16" Valve type:Check Valve Construction: Wafer type Design std: API 6D Pressure rating: PN10 Flange std: ANSI B 16.5 150# Material of Construction Body: Mild Steel Disc: Carbon Steel Seat: EPDM Operator: Self with all lead and lift.etc complete as directed by the engineer incharge.

2

-

58800

... More
AIR AND VACUUM RELEASE VALVES Providing and fixing commissioning of high quality Air & Vacuum Valve so as to discharge air during the filling or charging of the system, and intake air into the system during system drainage. As the system starts to fill, the valve shall function according to the following stages: ·        Entrapped air is released by the valve. ·        The liquid enters the valve lifting the float and sealing the valve. When internal pressure falls below atmospheric pressure (negative pressure): ·        The float will immediately drop away from the orifice. ·        Air will intake into the system. The air and vacuum release valves shall confirm to the following specifications. Working pressure range: 0.2 bar – 10.0 bar Testing pressure: 16.0 bar Working Temperature: 60 degrees Celsius Material of Construction Body: High tensile, UV Resistant, Engineering Plastic Internals:Corrosion resistant- with all lead and lift.etc complete as directed by the engineer incharge.

4

-

16800

... More
DIFFERENTIAL PRESSURE SWITCH Providing and fixing commissioning of differential pressure switch across the battery of active media filter for sensing drop in pressure across the filter battery and feedback to control panel. The Differential pressure switch should be an analogue type differential pressure indicator to be used to sense differential pressure build up across the pre filtration and media filtration system, independently. The differential pressure switch must be of heavy duty diaphragm type confirming to the following specifications including with all lead and lift.etc complete as directed by the engineer incharge. Differential Pressure Range:0-50" H2O (0-125 mbar) to 0-30 PSI Accuracy :�5% F.S. Max. Working Pressure : 1,000 PSIG (70 bar) Operating Temp. : -40� F To +200� F (-40�C to +93�C) Body Material: Aluminum, Brass, 316/316L Internal Materials: 316 Stainless Steel Elastomers : Buna-N (Std), Viton, Neoprene, Ethylene-Propylen Switch Mounting : Pre-set in Tube, Flat Pack, Din Connector Process Connections: 1/8" FNPT Bottom Connections etc if any with all lead and lift complete & as directed by engineer-in-charge.

1

-

16800

... More
SOLENOID COILS Providing and fixing of electrical solenoid coils for hydraulic circuit regulation. The solenoid coil should be a compact 3-Way Latching Solenoid Pilot Valve, comprised of two main components: 1.      A dry solenoid actuator and 2.      A 3-way hydraulic pilot valve. The actuator is neutralized from water damages by an isolating membrane, which hermetically isolates it from the water. The coil should consume power only when switching positions, using a very short electric impulse. The hydraulic base should feature a manual override and consist of a bracket for attaching to the valve or to a solenoid manifold. The solenoid coil shall confirm to the following specifications: Operating Pressure Range: 0-10 bar Base Port: 1/8” NPT Base Orifice Diameter: 2.2 mm Base Flow Factor: a) Pressure port Kv = 0.12 m3/h @ 1 bar ΔP; Cv = 0.14 GPM @1 psi ΔP b) Exhaust port Kv = 0.14 m3/h @ 1 bar ΔP; Cv = 0.16 GPM @1 psi ΔP. Actuator Casing: Nylon Seals and Isolating Membrane: NBR Wetted parts: Nylon Base: Nylon Voltage Range: 12-50 VDC. Coil Resistance: 4.2 Ω Pulse Width: 20-100 mSec Required Capacitor: 4700µF Operation Modes (electrical connections): a) + Red & - Black: Solenoid vents b) + Black & - Red: Solenoid pressurizes with all lead and lift.etc complete as directed by the engineer incharge.

24

-

201600

... More
INTERCONNECTING WATER PIPING Providing and fixing commissioning of interconnecting piping for security filter along with suitable flanges & counter flanges of ANSI B16.5 #150 class along with necessary nuts, bolts and gaskets, complete in all respects. The water piping shall be sized for a maximum velocity of 2.4m/s and pressure drop limited to 4m WC per 100m equivalent length. However, gravity lines and pumps suction line, shall be sized for a maximum velocity of 1.5 m/s. All piping, fitting and accessories shall be designed to withstand the maximum pressure in the corresponding line that may occur in the system under normal condition any exigencies. Pipes MOC: M.S. Tube Heavy Class-C ERW I.S. 1239/ 1964 Joints & Flanges: Screwed Unions, Slip on flanges Sealing Material: Non-Hardening Lubricant, 3mm, 3-ply, Rubber insertion All piping shall be black steel unless otherwise stated and from standard manufactures. Pipes shall be given one primary coat of red oxide paint before being installed except for insulted pipes. Pipe shall be sloping towards drain points. Fittings shall be new and from standard manufactures. Fittings shall be of malleable casting and of pressure ratings suitable for the piping system. Fittings used on welded piping shall be of the weld able type. Flanges shall be new and from standard manufacturers. Supply of flanges shall include bolts, washers etc. as require. Use of flanges made from plates will not be permitted. All pipes and fittings, valves, flanges etc. shall conform to piping element specification MSD— Tee-off connections shall be through reducing tees upto 150mm, otherwise ferrules welded to the main pipe shall be used. Drilling and tapping of the walls of the main pipes, shall be through unions/screwed flange upto 50mm dia and welded flanges for larger diameter. All equipment and valve connections, or connection to any other two or more meeting pipes, shall be through unions/ screwed flange upto 50mm dia and welded flanges for larger diameters. All welding shall be done by qualified (I.T.I – 6GR Grade) welders and shall strictly conform to BIS code of practice for manual metallic welding of Mild Steel. All weld joints shall be die penetrant tested and shall be hydro tested for any leakages. including with all lead and lift.etc complete as directed by the engineer incharge.

1

-

3842300

... More
PRESSURE GAUGE Providing commissioning of high quality, industrial grade pressure gauges at various locations for measurement of pressure. The pressure gauge shall be filled with glycerine for adequate dampening. Dial Size: 6” Range: 0 – 10 bar with all lead and lift.etc complete as directed by the engineer incharge.

6

-

21000

... More
CONTROL SYSTEM Providing commissioning of PLC based control panel for controlling Filtration and Backwashing sequence of Media Filters. The Panel shall comprise of PLC, HMI Screen, inbuilt transformer, contactors, relay, safety fuses etc complete in all respects to work on single phase 230 VAC and step it down to 24 VDC which is the required control voltage. The panel should be programmable with focus on ease of use, for changing flushing frequency, flushing duration, DP values, dwell times, master valve control etc. The panel shall be made of high quality weather resistant enclosure. The panel shall be connected with adequate lengths of high quality 0.75 sq. mm copper control cables to the external instrumentation such as DP switch & Solenoid coil. including with all lead and lift.etc complete as directed by the engineer incharge.

1

-

1029000

... More
FILTER SHED Construction of suitable foundation & building with brick wall for Filtration plant 0f 15 mtr x 25 mtr including earth work excavation in all soils , providing and laying PCC of M-10 and raft of M-20 garde. Self supported Galvalume sheet of BMT 0.7 mm as per site condition, minimum height of 4 mtrs from the Finished floor level. Necessary illumination points inside of 6 twin fluorescent tubes, and outside Six MV/SV lamps of 140 watts, with extra power points 1 mtr. wide projection on all sides to protect the plant from Rain & Sunlight etc if any with all lead and lift complete & as directed by engineer-in-charge.

1

-

4410000

... More
RAW WATER PUMPING MACHINERY AT HEAD WORKS -Raw water submersible Pumpsets: Supply & delivery at site brand new, best efficient make vertical suspended raw water submersible pumpsets pumps conforming relevant standards and the followS a)Duty Condition: Capable of delivering 125 LPS of Turbid water containing turbidity upto 4000ppm against a total head of 115 m during solo operation and capable of delivering 250 lps against a total head of 115 m during parallel operation,b) Speed: Duty condition should be met at 1500 RPM.(Syn),c) Shutt off head: Min 110 % & Max 130 % of the specified head, d) Material of construction-Motor Casing, Oil Chamber :Cast Iron (FG 260 as per IS 210 or GG25 or EN-JL1040),Motor ‘s (Squirrel Cage) Rotor:Copper Bar only,Mechanical Seals: • Primary (Inboard) : Silicon Carbide v/s Silicon Carbide or Tungsten Carbide v/s Tungsten Carbide •Secondary (Outboard): Carbon v/s Cast Chrome Molybdenum Steel or Carbon v/s Silicon Carbide or Tungsten Carbide, Elastomers:O” rings of Viton Bellows of either Viton OR Nitrile,Fasteners: Stainless Steel,Pump (Bowl) Casing:Cast Steel – ASTM A 216, GR WCB,Impeller :Cast Austenitic Stainless Steel (SS 316 or CF 8M or 1.4406), Wearing Rings : Cast Austenitic Stainless Steel (SS 316 or CF 8M or 1.4406, Pump-Motor Shaft: Stainless Steel (SS 410 or SS 430 or 1.4021 or 1.4460),Suction Strainer: Stainless Steel 202, Portable Stand( Suspended stool) : MS (C15) Fabricated with Epoxy Coating, Delivery pipes of 300 mm dia, 8 mm thick , MS pipes of suspension length 18 mtrs approx( including the pump and motor), MOTOR: The submersible motor shall be dry, squirrel cage type suitable for 3 phase, 50 cycles, 415 volts AC supply suitable complete confirming to ISS:325/1976 shall be of such capacity to provide under working site condition a power more than the maximum power required by the pump. Continuous duty with class 'F' insulation. Winding of the motor shall be impregnated by resin. Motor shall have integral cable entry port better starting torque characteristics. The enclosure for motor shall be IP-68. Each phase of the motor provided with thermic switches of Bi-metalic electro-mechanical temperature detectors. The motor shall operate satisfactorily at all operating levels at Javkwell. The motor shall be sealed against entry of liquid being pumped by using two mechanical seals. Motor pump should have the following in built protection connections,l) Thermistors protection connection against over heating of motor by thermister embedded in each phase,2) Sensor monitor connection against entry of liquid in the oil chamber by the moisture sensor provided inside the oil chamber,3) Reverse rotation protection connection device which trips the motor in case of reverse rotation due to wrong electrical connection,4) Bearing temperature sensor for protection from overheating of Bearings,5) Moisture sensor for detection of leakage in stator housing,6) The motor shall be suitable for starting the pumpset with suitable starter, Note:- Submersible pumpset should be installed in the jackwell and will be submerged. Hence, the pumpset should suit above system,Orientation:Vertical, Installed by:Portable Stand (Vertical),Suitable BTD's shall be provided for bearing temperature indication for both DE and NDE side and shall be terminated in terminal box for connection to SCADA system/ temperature scanner-etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

12808119

... More
ACCESSORIES FOR PUMP: M.S Chain-8 mm thick -etc with all lead and lift complete & as directed by engineer-in-charge.

105

-

132720

... More
DOUBLE FLANGED PIPES & SPECIALS :Supply & delivery at site brand new best indegenous make double flanged Mild Steel 8.00 mm thick pipes & specials suitable for test pressure equivalent to twice the working pressure. The pipes should be coated with food grade epoxy primar coat of 45 microns thick and two coats of food grade nonphelic/nontoxic Berger/ poladian/ Akzo Noble make epoxy paint of 80 microns thick each coat inside and anticorrossive paint outside. The Pipes should be tested as per IS 3589/1966. The Welding should be done as per IS 2825-1969. The thickness of flanges should conform to IS 6392-1971. The specials should conform to ANSI 16.9-For delivery side :Minimum 300 mm dia or suitable size MS flanged pipes-etc with all lead and lift complete & as directed by engineer-in-charge.

90

-

353430

... More
-do- Minimum 250mm x 350mm dia or suitable size flanged concentric reducers --etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

30759

... More
-do- Minimum 350mm dia or suitable size flanged radial bend etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

6846

... More
For Delivery Manifold : Supply & delivery at site brand new best indegenous make M.S. pipe manifold of 8 mm wall thickness and 600 mm dia or suitable size flanged pipe etc with all lead and lift complete & as directed by engineer-in-charge.

30

-

186450

... More
-do- For Minimum 600 mm dia blank flange - etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

7312

... More
-do- For Minimum 350 mm x 600 mmx 600 mm dia or suitable size flanged Tee etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

110661

... More
-do- For Minimum 600x600x150mm dia or suitable size flanged Teewith radial branch for pressure relief valve etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

33707

... More
-do- For Minimum 150mm dia 'B' class GI pipe of any Board approved make for connecting outlet of pressure releif valve etc with all lead and lift complete & as directed by engineer-in-charge.

10

-

6630

... More
Sluice valve :Supply, & delivery of resilient sealed soft sealing sluice valves with body, bonnet of ductile iron of Grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of Vacuum tight and 100% leak proff with face dimensions as per BS 5163-89/ IS 14846-2000/ DIN3202 F4\f5 . The stem Sealing should be with Torodial sealing rings ( Minimum 2 O-rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The Valves shall be supplied with suitable size galvanised bolts and nuts of requied numbers of GKW/KITO/NLXO/TECHMAN any other equivalent international approved brand-a)Diameter - 350mm,b)Working pressure-16 kg/cm2, Material for component Parts,Body and bonnet : Ductile cast iron of grade GGG50,Stem : AISI 410 Stainless Steel IS 6603 Gr. 12 Cr12,Wedge: Ductile iron GGG50 Rubber lined with EPDM,Wedge nut: Bronze,Bolts and nuts: Stainless steel,Bonnet Gasket: EPDM-etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

376462.71

... More
-do- DI 150 mm dia Sluice valve PN 16 without actuator-etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

21477.17

... More
Ductile Iron check valves without damper arrangement: DI Double flanged tilting disk swing check valves with slanted seat or with stright disc with metallice corrosion proff and wear resistant seal faces with nickel overlay micro finished with body and disc in DI grade GGG50 shaft of stainless steel and bearing of zinc free bronze and surface protection with epoxy liquid of GSK quality-a) Diameter-350 mm,b)Working pressure 16 kg/cm2,Material of construction:Body : Ductile cast iron grade GGG50 / SG iron 500/12, Disc:Ductile cast iron grade GGG50 / SG iron 500/12 with valcanised rubber, Shaft : Stainless steel,Coating : Double coating of epoxy liquid lacquer inside and outside of GSK quality -etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

759505.11

... More
Pressure guage:Supply and delivery at site any Board approved make glycerene filled Stainless steel pressure gauge of 150mm dia suitable for the above pumpsets with nipple, stop cock & two way cock for cleaning & necessary length of copper tubing suitable for mounting on the delivery of pump- etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

6000

... More
CONTROL SWITCH GEAR PANELS:Supply and delivery at site brand new any Board approved make floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 440 volts AC supply fitted with the follows-450 Amps MCCB with current setting range of 400-630 Amps of any other Board approved make of 50 kA breaking capacity with U/V release, shunt release and suitable thermal release -3 Nos,3 No. Micro processor based Earth leakage relay with resin cast CBCT of Proke's dv's /or any Board approved make., U/V/O/V numeric relay with negative phase sequence protection of Proke's dv's /or any other Board approved make or equivalent- 3 Nos,Phase indicating lamps with switches of any Board approved make- 3 sets,Panel mounting version digital Micro processor based type Multi function meter for measuring current, Voltage, P.F, energy etc., of any Board approved make or equivalent. With RS 485 port- 3 Nos,MS air insulated bus bar chamber with 4 Nos 800 Amps 25 MVA Air insulated bus bar made of high conductivity, high strength aluminium alloy complying with the requirements of grade E91 E of IS 5082, suitably braced with non-hygroscopic SMS supports. Provision shall be made in the bus bar chamber for 3 incoming and 9 outgoing feeders. The bus bar chamber should be of adequate capacity to handle the incoming and out-going cables and for fixing the switchgears as per requirement-1 No, 500 Amps load break switch unit conforming to the latest ISS for Motor circuit of any Board approved make. 3 No, 160 Amps TPN switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for Capacitor circuit of any Board approved make. 3 No,32 Amps DP load break heavy duty switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for lighting circuit of any Board approved make. 3No, Set of cable entries and terminals suitable for numbers, type and size of aluminium conductor power cables, etc,2 nos. of Aux. relay VAA-33 for alarm and trip system of WTI and OTI for each transformer, NOTE:1) The panel board shall be complete with all other required fittings, and shall be fabricated using 2mm thick sheet steel and wiring shalll be done using suitable size copper cable/copperwire painted with two coats of a highly corrosion resistant primer applied wet on wet and a finishing coat of synthetic enamel paint of the ash greay shade, 2) H.R.C. fuse link rated not less than 1.5 times the rated current of the capacitor bank shall be provided in the suitable Amps capacity switch fuse unit for capacitor circuit,3) The internal wiring shall be done using adequate size insulated electro tinned copper strip or cable of 1.1 KV grade, 4) Any discrepancies are noticed apart from tender specification, suitable action as per tender condition will be taken against the tenderer including black listing of the tenderer,5) Any discrepancies are noticed apart from tender specification, suitable action as per tender condition will be taken against the tenderer including black listing of the tenderer,6) The Bus bar chamber should be of adequate size to accommodate all incoming, outgoing cables and required switchgears etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

463016

... More
11 kV group VCB Panel -11KV SWITCH GEAR PANEL:( 1 incoming breaker ,3 Nos of outgoing load break switch) Supply and delivery at site brand new any Board approved make 11 kV, 350 MVA weather proof outdoor KIOSK with IP54 or better protection grade with 3ph ,50 cycle VCB panel conforming to IEC-56 suitable for outdoor installation with incorporating the following accessories including loading & unloading, Transportation. Necessary adopter panel shall be supplied along with breaker panel, 1 No of incoming Breaker panel consiting of 1 No. of 11kV TP Vacuum circuit breaker, horizontal drawout type suitable for rated current 800A and short time rating of 25 kA for 3 seconds of any Board approved make fitted with the following 1 No. of 230 volts AC 50Hz or 110 V D.C.universal motor charged spring closing mechanism, 1 No. of mechanical on/off indicator,1 No. of 110VDC closing coil, 1 No. of 110VDC shunt trip,1 No. of close/trip control switch of Alstom make,1 set of space heaters with switch, 1 No. of Local/remote selector switch,1 set of castell type mechanical interlocks,1 No. of mechanical Stroke counter,1 No. of 15A, 230V, AC SP socket with switch,1 set of Red/Green indicating lamps for circuit breaker on/off indication of LED type of Board approved make,1 No. of amber lamp for trip on fault indication of LED type of Board approved make,1 No. of white lamp with push button for on demand trip circuit healthy indication of LED type of Board approved make,1 No. of Blue lamp for spring charged indicator of LED type,1 No. of panel illuminating lamp with door limit switch of Board approved make,3 Nos. of Resin cast type twin secondary current transformers conforming to IS 2705, ratio 100/5-5A , class 5P10/class 1.0 accuracy with 15 VA burden for protection and class 1.0 accuracy for metering suitable to withstand short time rating of 25 KA for 3 seconds,3 No. Single Ph, resin cast drawout type potential transformer conforming to IS 3156 ratio 11 KV/ /3 /110V/ /3 Class 0.50 accuracy, 100VA Ph burden, complete with HT and LT fuses and connected to incoming side of the breaker and to the common bus,3 Nos. Terminal connectors for CT's,3 Nos. Terminal connectors for PT's,3Nos of Flexible connectors for connection between breaker & CT's,1set of 6N/O +6N/C spare auxiliary contactors,1 No. of Digital type any Board approved make Ammeter to read R, Y, B, phase currents,1 No. of Digital type any Board approved make Voltmeter to read Voltages,1 No. of Multi function meter for mearuement of current , voltage, P.F, KWH, KVAR etc., of any approved make or equivalent with RS 485, 1 No. of Electronic type, Trivector meter of class 0.2 accuracy with RS 485 port,1 No. Numerical U/V/O/V relay with negative phase sequence protection,1 No. High speed numerical master tripping relay, 1 No. Trip circuit supervision relay,1 No of Numerical overcurrent and Earthfault relay,4 Nos. of 1 foundation bolts,12 window annuciator panel for braker on/ off/ trip/ healthy / relays trip etc,3 Nos of Outgoing Breaker panel with necessary interlocks each comprising of 3 Nos of load break switch Panel-Supply, erection, electrification and commissioning at site brand new any Board approved make load break switch panel suitable for out door unit for operating on 11 kV , 50 Hz 3 phase AC supply. The panelshall consists of the following equipments as details below-a) On load 630 amps air break switch with fuse trip mechanism and tripping circuit suitable for 3 phase, 11 kV, 50 Hz AC supply,b) Suitable capacity HRC fuses with trip arrangements,c) Bus bar of adquate capacity,d) Panel shall be provided adequate space for accomadation of incoming and outgoing cables Note:1. The vaccum circuit breaker is required for installation in the solidly earthed system 3 phase 50 Hz 11 KV AC supply,2. The auxiliary switches with minimum no. of 10 normally opened and 10 normally closed contacts for indication control interlock with Isolator protection etc., shall be provided,3. The breaker is required for installation at a site whose altitude does not exceed 900 mtrs. & the maximum ambient air temperature does not exceed 45 degree C, 4. The equipments should also include suitable size 33KV panel to mount volt meter, Ammeter frequency meter, Kilowatt hour meter protective relays suitable control wiring from CTs, PTs, and switchgear should be brought to the panel, which is to be erected in the pump house,5. The tenderer should calculate the fault level as per the single line diagram furnished and propose the vacuum circuit breaker accordingly,CODE & STANDARDS:Vacuum circuit breaker IS 13118-1991, 2516 BS 5311 & IEC 56,Panel IS 3427 1969,Current Transformer IS 2705 1981,Voltage Transformer IS 3156 1978-etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

817600

... More
Transformer:Supply, erection, electrification and commissioning at site, brand new any other Board approved make oil immersed naturally cooled continuous duty with Copper winding 400 kVA 11 kV/433 volts 3 Ph 50 Hz Dyn 11 vector group distribution transformer conforming to IS1180 or its latest amendments fitted with the following and suitable for outdoor installation. The no load losses and full load losses shall be as per level 3 standards (5 Star Rating)a) Dehydrating breather,b) Oil conservator,c) Drain plug for conservator,d) Off ciruit tap changer -5 TO +5 % in step of 2.5%,e) Thermometer pack with the thermometer,f) Base channel - 2 Nos,g) Lifting lugs 2 Nos,h) Flat rollers,i) Connecting pipes,j) Oil guage - 1 No,k) Filter valve,m) Air release plug - 1 No,n) Filter cum drain valve,o) Winding temperature indication with alarm and trip contacts,p)Oil temperature indication with alarm and trip contacts,q) Residual oil drain plug,r) Explosion vent,s) Detachable Radiators,t) Bushing for high voltage side,u) Cable box for low voltage side,v) Double float gas actuated Buccholz's relay with alarm and trip contacts,w) Earthing terminals,x)Marshalling Box,y) Oil filling hole with cap,The transformer shall be fitted with all other standard fittings and painted with high grey paint to shade No. 631 of ISS & shall be supplied with first filling of transformer oil etc., complete (test certificate shall be furnished)- etc with all lead and lift complete & as directed by engineer-in-charge.

6

-

6774720

... More
LIGHTENING ARRESTORS: Supply and delivery at site brand new best indegeneous make 9kV 5 kA valve type metal oxide lighting arrestors (distribution type) for providing surge protection on the high voltage side of the transformer conforming to the latest ISS 3070-etc with all lead and lift complete & as directed by engineer-in-charge. (Each consisting of set of 3 Nos)

7

-

14490

... More
11 KV GANG OPERATED DISCONNECTING SWITCHES:Supply and delivery at site brand new Best indegeneous make triple pole horizontal type suitable for outdoor installation air break gang operated off load isolator with earth blade 11 KV 400 Amps. 250 MVA triple pole, gang operated three insulator stock per pole, tilting type double break per phase air break isolator.Switch suitable for operation 3 phase, 50 c/s, 11000 Volts AC supply horizontal mounting type for outdoor installation conforming to the latest ISS 1818 along with all the required accessories. The isolator shall be complete with a) GI operating down pipe complete with handle pad lock key and arching horns, handle earthing wire etc., complete,b) Auxillary switch with 8 auxillary contacts, 4 for making contacts at circuit opening and 4 at circuit closing-etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

52635

... More
Horn Gap Fuses : Supply and delivery at site brand new best indegeneous make horizontal mounting suitable for outdoor installation 11 KV, 3 phase, 50 c/s 200 amps 250 MVA capacity high voltage horn gap fuse units with suitable capacity fuse along with operating hickery rod for operations of fuses from ground etc., complete with all the standard fittings -with all lead and lift complete & as directed by engineer-in-charge. (Each consisting of set of 3 Nos)

4

-

14000

... More
Digital softstarter-Supply, delivery and commissing at site brand new board approved make or equivalent floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 400/440 volts AC supply fitted with the following,450 amps MCCB or suitable with fixed and moving contracts fitted with U/V release, shunt release and with suitable thermal release.- 1 Nos,Multi parameter such as current, kwhr, Voltage, KVA reading digital meter of prok devices or any other Board approved make - 1 Nos,Phase indicating lamps with switches of L&T/ BCH/ GE make or any other make approved by the Board - 1 set,The soft starter shall have a facilitty to start the sewage pumpsets by reducing the starting current less than 1.5 to 2 times the full load current. It shall have bulit in facilities such as SPP, Over Voltage, Under voltage, Kick start for pump jam conditions , overload, overcurrent etc., for protection of the pumpsets. The starting current shall be controlled by three phase thyristors. suitable for minimum 250 kW motors,The starter shall be provided with suitable Amps by pass contactor if not built-in in the starter-1 No,The panel shall be provided with cooling fan, louvers with fine mesh to facilitate the cooling of thyristors/ soft starter,The panel should be adequate size to accomadate all incoming, outgoing cable and required switchgear and other accessories,Digital P.F.Meter of any Board approved make,Control supply voltage will be 230 volts AC,Alarm hooter, Suitable size cable gland for I/c & O/G cables,Space heaters with switch, plug and socket, panel lamp working on 230 V AC,Bus bars should be of Aluminium/Copper,NOTE for soft starters,1.The soft starter shall be rated equivalent to the motor rated power and shall be capable of operating satisfactorily with the motor under the various loading and starting conditions of the motor over the entire range of operation,2. The soft starter shall reduce, the starting current of the motor atleast to 60% of the direct line starting current of the motor. The soft starter shall have facility to further reduce the current upto 50% of the direct on line starting current if the motor and the pump torque speed curve permits,3. The soft starter shall work on the principle of unsaturated core in the working zone and shall not lead to generation of Harmonics,4. Soft starter shall be so rated as to allow two consecutive starts from cold or one hot start per hour,5. Soft starter shall be designed for supply voltage of '+OR -10% AND Frequency Variation of +OR - 3% or a combination of both,6. The winding of the soft starter shall be with insulation class "F"and maximum temp of winding shall be limited to that of class "B",7. The soft starter shall be housed in a sheet steel enclosure of thickness not less than 14 guage and painted with corrosion resistive paint such as epoxy of Polyurethene. The degree of protection shall be IP 41,8.The starter shall not contain any active electronic components,9. The starter shall have a built in facility for run bypass so that the incoming voltage to the motor is equal to the supply voltage,10. The Soft starter unit should be Air cooled,11. The soft starter shall be dust and vermin proof and suitable for indoor mounting-with all lead and lift complete & as directed by engineer-in-charge.

3

-

1405350

... More
Power Capacitors: Supply and delivery at site brand new best indegeneous make 3 phase, 50 c/s 440 volts suitable KVAR All Polypropelene type power capacitor conforming to the latest ISS 2834 suitable for indoor installations at a site whose altitude is 50-Note:- The capacitor is required to keep the total power factor of the installation at not less than 0.95 lagging-with all lead and lift complete & as directed by engineer-in-charge.

324

-

72900

... More
Main side cable:- Supply and delivery at site brand new Iany Board approved make Aluminium standard conductors PVC insulated ,sheathed steel tape/wire armoured, XLPE insulated , PVC tape innersheathed, 1.1 KV class UG Cable conforming to the latest ISS 1554.The length of the cable supplied shall be as per site conditions. The quantity indicated is only approximate and the successful bidder shall measure the quantity required at site before procurement of cable. with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x 185 sq mm

400

-

434400

... More
Load side cable:- Supply and delivery at site brand new Iany Board approved make Aluminium standard conductors PVC insulated ,sheathed steel tape/wire armoured, XLPE insulated , PVC tape innersheathed, 1.1 KV class UG Cable conforming to the latest ISS 1554.The length of the cable supplied shall be as per site conditions. The quantity indicated is only approximate and the successful bidder shall measure the quantity required at site before procurement of cable-with all lead and lift complete & as directed by engineer-in-charge. For 3 x 240 Sq mm

150

-

179400

... More
-do- For 3 x 120 Sq mm -with all lead and lift complete & as directed by engineer-in-charge.

30

-

18600

... More
11 KV HT XLPE CABLE: Supply and delivery of aluminium XLPE HT cable earthed, glavanised steel flat strip armoured for the purpose of connecting from metering cubical to pole structure and from there to breaker panel of any Board approved make. The length of the cable supplied shall be as per site conditions. The quantity indicated is only approximate and the successful bidder shall measure the quantity required at site before procurement of cable-with all lead and lift complete & as directed by engineer-in-charge.For 3 x 120 sqmm

80

-

93760

... More
PRESSURE RELIEF VALVES:Supply, delivery and erection of site brand new DOROT(S-300 series)/BERMAD/ ERHALD/ SINGER make pressure relief valve of 150mm dia with the following specifications. (PN 16),1)Valve should have direct sealing diaphragm activated by line pressure and controlled by 2 way diaphragm operated adjustable pilot valve, 2) Valve should be installed on a Tee junction, which should modulates automatically to maintain present inlet pressure and releive the excess pressure out of the network,MATERIAL OF CONSTRUCTION :1) Body and Bonnet - Ductile Iron ISO 1083 Grade 450-10, 2)Diaphragm - Natural rubber (standard), 3)Spring - SS 302,4) Pilot valve - Brass ISO 426,5) Coating - Electrically applied over baked polyster, The outlet of pressure sustaining valve should be connected to sump using MS pipes and fittings with all lead and lift complete & as directed by engineer-in-charge.

1

-

219520

... More
Supply of of 11 kV HT Metering Panel with 3 CTs 3 PTs for 3 phase 4 wire metering with transparent cover TTB, with Cu Bus bars (HT Metering Box fabricated out of 3mm MS sheet duly epoxy powder coated with HT Electronic Tri-Vector Meter of Class-0.2 class with ABT features & DLMS protocol with ToD with all single ratio CTs of suitable class, ratio, burden for 3 phase 4 wire metering with load break switch. as per ESCOM specifications with all lead and lift complete & as directed by engineer-in-charge.

2

-

376584

... More
FIRE FIGHTING EQUIPMENTS :Supply and delivery at site brand new fire extinguishers consisting of 2 Nos. of 2 kg capacity cylindrical type carbon di-oxide gas pressure type suitable for 25 to 35 feet range operation with initial charge and suitable brackets as per fire extinguishers regulations.- 2 Nos, b) Supplying and fixing of first aid box comprising of the standard medicines to be provided in the first aid box to give first aid treatment - 1 No c) Providing shock treatment chart on wall with inside plastic sheet cover and ply wood backplate frame work complete, d) Supply one set of fire buckets (4 Nos) with round bottom made of GI sheets 24 SWG 9 ltrs. capacity painted inside white and outside red with a word `fire' on the face of the bucket along with stand to hang the buckets, e) Supplying rubber gloves, electrical quality, tested to 22KV - 1 Pair, f) Supplying and fixing of Danger/No Admission/No Smoking Board made out of MS sheet metal with two coats of non-corrosive enamelled paint with all lead and lift complete & as directed by engineer-in-charge.

3

-

30000

... More
TOOL KIT :- Supply and delivery at site best any Board approved make and other reputed make tool sets for operation and maintenance of the above pumpsets comprising of the following. a) Double end spanner 1/4" to 1"- 1 set, b) Screw driver insulated 11" - 1 No, c) Screw driver insulated 8" - 1 No, d) Cutting puller insulated 8" - 1 No, e) Hammer with handle 1 Kg - 1 No, f) Pipe wrench 24" -1 No, g) Pipe wrench 18" -1 No, h) Pipe wrench 12" -1 No,i) Hammer with handle 5Kgs -1 No,j) Grease gun - 1 No,k) Ring spanners 1/4" to 1" - 1 set, l) Supply of Testing Equipment (oil testing kit, Motorised megger of 5 kV, Manual megger of 1 kV, Digital multimeter, Tong tester)-with all lead and lift complete & as directed by engineer-in-charge.

3

-

30000

... More
Manufacture, supply and commission Electromagnetic Flow Meter (EMF), for Raw/Pure water with accuracy 0.5% of measured value & protection as per given specifications for Nominal Diameter Flowmeter. Including sensor, transmitter surge arrestor, cable GI duct if suitable size for 25 mtrs. sensor, transmitter surge arrestor, 25 Mtrs / each flow meter, including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes etc., as may be required at site & based on technical specifications below: A) Mandatory Accessories: 1) The sensor should be as per IP-68 protection & with flanges of up to PN 10 rating from CS-1 No. 2) The sensor coil housing shall be IP-68.This protected against external magnetic field. 3) The transmitter shall have one current 4 m A-20 mA output -4) The current output shall be galvanically / optically isolated. It shall be fitted with switched mode power supply capability 85-260 V & 45-65 Hz to cope with power transients without damage. 5) Signal & power cables shall be of 50 Mtrs length/each. 6) Conduit pipe ( PVC Plumbing schedule 4 ) 25 mm diameter with suitable rating of cable with digging, laying & concealed the duct - 25 mtrs/each. 7) UPS working on 230 V AC, 50 Hz power supply suitable for 12 hrs continuous operation-1 No. 8) Data storage capacity with built in or separate for date time, actual flow rate, totaliser & error messages if any with storage capacity of 120 days at 1 hour interval data logging-1 No. 9) 21",80 column Dot matrix printer of EPSON, WIPRO, or Hewlett Packard make with printer interface unit for printing of stored data as per 8 )-1 No. 10) Proper earthing shall be provided for protection against high voltage surge. 11) Suitable over voltage protection unit for protection of instrument from higher voltage (upto 275 V-300 V AC)-with all lead and lift complete & as directed by engineer-in-charge. For 600 mm dia

1

-

525000

... More
ERECTION OF CAPACITORS : Formation of suitable CC foundation in CC 1:2:4 using all the required materials such as cement, sand,jelly etc., complete and erection of the capacitor on the above foundation using the required materials etc., complete including the cost of all the materials - (3 banks)- with all lead and lift complete & as directed by engineer-in-charge.

1

-

5000

... More
ERECTION OF 3 No. TRANSFORMER and Sub station:(11 kV) Erection of substation structure fabricated out of beams erection of substation equipments such as two pole structure, iron channels , strain insulator, pin insulators, fixing of Isolators with earth switch, lighting arrestor ACSR, bus conductor etc., complete including painting the structure with best quality weather proof approved paint over a coat of anticorrosive primer, providing and fixing of anticlimbing device danger board, etc., complete including providing necessary foundation for the pole structure in CC 1:3:6 including the cost of all materials etc., complete. including erection of load break switch panel and metering cubicle panels with necessary foundation and other equipments which are not specifically indicated with all lead and lift etc., complete. Formation of suitable elevated platform in size stone masonry in CM 1:6 using all the required materials such as cement, sand, jelly etc., complete and with MS rail embeded on the top of the platform, hoisting the load break switch panels, transformer etc for the erection on the above platform and erection of the panels on the platform including the cost of all the materials required labour etc., complete with supply and spreading of 40 mm down size jelly all round the substation.Construction of platform with size stone, cement concert for erection of Transformer, Braeker panel and Metering cubicle .Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour. Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6.Providing and Laying cement concrete slab 1.5x1.5x0.10Mtr with cement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely-with all lead and lift complete & as directed by engineer-in-charge.

6

-

669900

... More
INSTALLATION OF STARTERS:Formation of suitable foundation CC 1:2:4 using all the required materials such as cement, sand, jelly etc., complete and erection of switch gears and starters on the above foundation using the required materials such as bolts, nuts washers with all lead and lift complete & as directed by engineer-in-charge.

3

-

24600

... More
Erection of Control Panel Board( 415V) on CC foundation including formation of CC foundation in CC 1:2:4 prop. using all the required materials such as cement, jelly etc., complete including erection of the panel board, on CC foundation using reqired materials such as MS channel bolts, nuts, washers etc., complete. with all lead and lift with all lead and lift complete & as directed by engineer-in-charge.

1

-

8200

... More
LAYING OF CABLE: The works shall include digging of trenches size of 0.60 Mtrs. deep & 1.0 Mtrs. wide providing providing sand bedding to the cables laying the cable in trench providing cable marking bricks refilling, consolidation the soil etc., complete including the cost of all the materials required for laying the cable as per IE rules labour with all lead and lift with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x 185 Sqmm -1.1 KV Class cable (mtr of 3 run)

100

-

16300

... More
-do- For 3 x 120 Sqmm 11 KV Class-with all lead and lift complete & as directed by engineer-in-charge.

40

-

6520

... More
LAYING IN G.I. PIPE: Running the cable in 2.9 mm thick suitable size GI pipe above the grand using all the required materials such as GI pipe clamps, bolts, nuts, washers etc., for fixing the GI pipes to the pole including the cost of these mateials labour with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x 185 Sqmm 1.1 KV Class cable (mtr of 3 run)

300

-

62400

... More
-do- For 3 x 120 Sqmm 11 KV Class-with all lead and lift complete & as directed by engineer-in-charge.

40

-

8320

... More
Laying of load side cable:- Running the cable in existing ducts including properly securing cable in position etc., complete using all the required materials ith all lead and lift complete & as directed by engineer-in-charge. For 3 x 240 Sqmm (mtr of 2 run)

150

-

5700

... More
-do- For 3 x 70 Sqmm -with all lead and lift complete & as directed by engineer-in-charge.

30

-

1140

... More
Cable Terminations: Termination of cable using Alluminium/copper lugs to the terminal end for solderless crimping to aluminimum conductors by adopting crimping tool-with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x 185 Sqmm 1.1 KV Class cable (main side cable)

27

-

9153

... More
-do- For 3 x 240 Sqmm 1.1 KV Class cable (load side cable) -with all lead and lift complete & as directed by engineer-in-charge.

24

-

11496

... More
-do- For 3 x 120 Sqmm 1.1 KV Class cable (capacitor cable)-with all lead and lift complete & as directed by engineer-in-charge.

6

-

1182

... More
Erection of pumpsets: Erection of the raw water submersible pumpset on the floor with necessary formation of machine foundation using suitable size MS channels, cross girder, plate girder, nuts & bolts, washers etc., complete. Lowering of Pumpsets, delivery pipe assembly into Jackwell and fixing of pumpset in position true to line vertically, maintaining the alignment, dynamic balancing and linking to delivery line proper packing of the hole after laying the pipe with CC 1:2:4 etc., complete. The work also includes providing necessary anti vibration mounts, Bolts, nuts fixing of sutiable clamps etc., including necessary civil works. The pumpset shall be mounted vertically and the discharge head of the pumps shall be connected to the the pipes, valves and delivery manifold which shall be mounted in the ground floor of pumphouse. The work includes erection of lifting chain and other accessories of the pumpset etc.,which are required for operation of the pumpset satisfactorily-with all lead and lift complete & as directed by engineer-in-charge.

3

-

60000

... More
Earthing : Maintenance free earthing system to be installed for the protection including formation of suitable size pit in all soils. The earthing system shall consist of EARTH ELECTRODE : Earth electrode shall be MS material subsequent hot dip galvanisation of minimum 250 microns / GI tubes to ensure maximum conductivity. The technology shall be either pipe in pipe or pipe in flat. The space in between shall be filled with high conductive compound which resist the corroision. The length of the electrode shall be 3 mtrs .Minimum of 50 mm dia electrode shall be provided for pipe in pipe technology,EARTH ENHANCEMENT COMPOND/Back fill compound: The compound used for backfilling the earth shall enhance the earth material conductivity . The compoundshall reduce the resistivity of the earth to less than 1 ohms. The compond shall be highly conductive and contain homogenous mixture of chemicals. It shall be environmental friendly, non corrosive, not explosive, not cause burns and irritation to eye, skin etc. The compond shall not contain bentonite, salt , charcoal and other dissolvable materials. The compound shall be insoluable in water and shall retain its moisture property upto the life of the electrode. The life of the electrode and pit shall not be less than 25 years without any maintainence. The quantity of compound shall not be less than 50 kgs/ pit- EARTH PIT CHAMBER: The earth pit chamber size shall be 300 mm x 300 mm x 5 mm concrete chamber with concrete slab or cover, TESTING POINT: Earth pit testing point shall be provided at the suitable location and above ground level,Testing shall be done after completion of installation. Final grid resistance of each area shall be measured and shall be within 1 ohm,NOTE:-1) All the equipments, such as switchgears, transformers lighting arrestors shall be earthed by two seperate and distinct connection as per IE rules and as required by electrical inspectorate without any extra cost,2) Necessary soil testing shall be carried out by the contractor at his own cost before carrying out the work,3) Since, the earthing points of different equipments and fault level are interconnected , the contractor shall submit the calculations for no of pits required before executing the work, 4) The work also includes connecting the common point of earthing to the earth pit with necessary coupler/ Extothermic welding as per IE rules, NOTE:- All the equipments, such as switchgears, transformers lighting arrestors shall be earthed by two seperate and distinct connection with the earth cover as per IE rules and as required by electrical inspectorate without any extra cost, with all lead and lift complete & as directed by engineer-in-charge.

48

-

600000

... More
Supply and fixing of GI earthing strip 50mm x 6 mm size for equipment earthing of transformer switch gear, meters motors lighting arrestors etc., The strips shall be laid and connected to the earth pit . The Strips shall be sleeved and protected aganist mechanical damages-with all lead and lift complete & as directed by engineer-in-charge.

380

-

76760

... More
LAYING AND JOINTING OF MS PIPES AND SPECIALS:Laying and jointing of MS pipes and specials for delivery connections of the pump using suitable size bolts, nuts, packing etc., complete including fixing of all types of valves, gauges, strainers, delivery & suction manifold. The work shall include providing pipe supports, thrusts block in CC 1:2:4 prop., wherever necessary upto the end of the delivery manIfold, using all the requied materials such as sand, cement jelly including making holes in sump, pump house for laying suction and devliery pipes, packing of holes with CC 1:2:4 etc with all lead and lift complete & as directed by engineer-in-charge. NOTE: The tenderer should furnish the layout drawing showing the position of valves, Tees, Pipes, providing for future pumpsets etc., and obtain approval from the Chief Engineer before taking up erection work.

1

-

10000

... More
Servicing and commissioning: The pumpsets along with all other elecrical equipments shall be serviced and commissioned in the presence of the Engineer-in-charge of work including trail running for a period of 90 days. The work shall include the following-Providing operating and maintenance manuals of the pumps and allied equipments to the operating personnel-Giving trail run of the pumpsets for a period of 90 days from the date of successful commissioning,The contractor should employ personnel to operate & maintain the pumpset and accessories during the trial run period and should train the Board/Municipal Staff to operate the pumpsets,1.The energy and water will be provided by the Board free of cost, 2. The pumpsets along with all the electrical equipments shall be commissioned only when the performance of switch gears, relays are wittnessed by the Executive Engineer in charge of the work and Asst. Executive Engineer (Electrical) of the Board- with all lead and lift complete & as directed by engineer-in-charge.

2

-

128000

... More
Cable End Seals:- Supply and fixing of 1.1 KV Indoor and outdoor type RAYCHEM/M SEAL /or any other Board approved make heat shrinkable /Push On type cable end seals with all required materials including copper lugs and terminals.,etc suitable with all lead and lift complete & as directed by engineer-in-charge. For 3 X 120 sqmm, 11 KV XLPE cable, outdoor earthed type- with all lead and lift complete & as directed by engineer-in-charge.

1

-

5470

... More
-do- for 3 x 120 sqmm, 11 KV XLPE cable indoor earthed type-with all lead and lift complete & as directed by engineer-in-charge.

12

-

62208

... More
TWO POLE STRUCTURE:Fabrication supply and delivery at site brand new best indegeneous make pole structure comprising of 175 mmx90 mm I-Section girders 9 m long,75mm x 40 mm size channels, 35 x 35 x 5 mm braces of required Nos., 11 KV pin insulators, 11 KV strain insulator,The work shall include design fabrication, supply and installation of out door sub-station structure as per the layout drawing enclosed which includes the following,a) Fabrication of the sub-station structure using the materials like galvanised mild steel section, channels, angles, flats, plates,rounds etc., for supporting isolator drop out lift of fuses.11 KV strain insulators, 11 KV support insulators for establishment, b)Installation of the sub-structure on CC foundation including providing concrete foundation in CC 1:2:4 using all the required materials such as 20 mm size jelly, sand, cement etc complete, c) Supply and fixing of 11 KV support insulators using all the required materials,d) Supply and fixing of 1.5 inch dia IPS aluminium tube for bus conductors or by using Rabbit ACSR conductors using all the required materials, with provision for extending the bus bar on both sides for future expansion,e) Fixing of disconnecting switches and drop out lift of fuse unit using all the required materials,f) Providing jump connections using Rabbit ACSR between the structure and HT bushings of the power transformer, g) Providing galvanised MS covers for static shield of the sub-station switch yard, NOTE:1)The work shall be complete enclosed using all the required materials,2)The following shall form the basis of design,a) The structure shall be designed so as to enable the structure to withstand without any injury or permanent deflection, test loads, equivalent to the respective working loads multipled by the fator of safety of 25,b) The ratio of effective length to the appropriate radius of gyration shall not exceed the following. i) For members having calculated stresses 200 ii) Redundents 250,3) The steel used for fabrication shall be of mild steel quality confirming to IS 226,4) Strain plates of suitable dimensions for engaging the U clamps of the strain insulator assembly shall be adequate strength,5) Necessary holes, U bolts shakles etc., for taking the ground wire clamps handling devices shall be provided,6) All the joints of the structure shall be made by using standard galvanised 16 mm dia bolts and nuts spring washers (3.5 to 4 mm thick squate in section and electric galvanised)-with all lead and lift complete & as directed by engineer-in-charge.

2

-

85600

... More
Chain linked wire fencing:- Supply and providing chain linked wire fencing for 11 kV transformer sub-station. The chain linked fencing should be with 2"x2"x8 SWG wire welded to angle iron frames of size 2.5 Mx2.5M using angle of 50x50x6MM. The frame be fixed to the supporting channels spaced at 2.5M of size 100x50mm 3.1 M height fixed in CC (1:2:4) at bottom etc.,including cost of all materials transportation and labour for fixing, silver painting etc., complete with door of 2.5M size at suitable places(including all taxes) Chain linked fencing shall be erected upon size stone masonry structure. The work includes providing & constructing granite/trap/basalt size stone masonry (0.45m wide, for aheight of 0.30m) in foundation cement mortor 1:6 stone hammer dressed in courses not less than 20 cm high, bond stones at two m apart and over plain cement concrete of mix M15 with OPC cement @240kgs, with 40mm and down size graded granite metal coarse aggregates @0.878 cum and fine aggregates @ 0.459 cum machine mixed concrete laid in layers not exceeding 15 cms thick, well compacted, in foundation and plinth for a thickness of 0.15 cm for foundation and 0.10 for coping including cost of all materials, labour, HOM of machinery, curing - with all lead and lift complete & as directed by engineer-in-charge.

80

-

280000

... More
Providing and fixing insulating mats with glowing strips for 1100 Volts - with all lead and lift complete & as directed by engineer-in-charge.

16

-

29184

... More
Pumps: Supply & delivery at site brand new, best efficient make approved by the Board horizontal split case centrifugal pump conforming to the latest IS 1520 & IS 5120 and the following description,a) Duty condition: Capable of delivering 113 LPS of Treated water containing turbidity upto 100 ppm against a total head of 116 mt,b) Speed: Duty condition should be met at 1450 RPM,c) Shutt off head: Min 110 % & Max 130 % of the specified head,d) Material of construction, 1) Casing- Cast Iron, 2) Impellor - CF 8 M,3)Shaft- Stainless steel shaft- SS 410, 4)Stuffing Box- Graphite Asbestos packing, 5)Wear Rings- CF 8M, 6)Gland- Cast Iron, 7) Inter Stage Ring- Phosphor Bronze, 8) Shaft Sleeve & Nuts- SS 410,9) Neck ring- CF 8M, e)Driving end bearing: Grease lubricated roller/ball/ journal bearing,f) Non driving end bearing: Grease lubricated deep groove ball bearing as well as journal bearing or deep groove ball bearng only,g) Coupling: Suitable size vibration proof flexible coupling with coupling guard, as recommended by the manufacturer of pump, for coupling to motor, h)Base plate: Heavy duty common CI/MS base plate for pump and motor wth suitable I section girders, channels, plates, bolts & nuts etc,NOTE: (1) The duty condition of the pump should be at BEP or to the left of the BEP,(2) The pump is required to work at an altitude of 800m. above MSL and at a max. ambient temperature of 45 degree C,(3) The Board reserves the right to select any stipulated make of pump. Horizantal Motor: Supply & delivery at site brand new, High efficient minimum 250 kW or suitable HP ABB/Marathon/Jyoti/Bharath Bijlee /CGL /or equivalent make Horizontal Foot mounted TEFC, squirrel cage induction 1500 RPM (syn)motor for continuous duty conforming to IEC :60034/IS 12615 for operation on 3 ph, 50 Hz. 430 volts. The efficieny valves of the motor shall be as per IE2,Protection : IP 55, cooling method: IC 411, Insulation: `F' class class with temp. rise restricted to class B, Ambient temperature: Upto 45 Degree C, Cushion: 15 % more than maximum power required by the pump and capable of providing rated output upto + or - 10% voltage variation and/or + or - 3% frequency variation or combination of Both, Driving end bearing: Grease lubricated roller bearing, Non driving end bearing: Grease lubricated ball bearing-with all lead and lift complete & as directed by engineer-in-charge.

3

-

7008179.25

... More
DOUBLE FLANGED PIPES & SPECIALS : Supply & delivery at site brand new best indegenous make double flanged Mild Steel 8.00 mm thick pipes & specials suitable for test pressure equivalent to twice the working pressure. The pipes should be coated with food grade epoxy primar coat of 45 microns thick and two coats of food grade nonphelic/nontoxic Berger/ poladian/ Akzo Noble make epoxy paint of 80 microns thick each coat inside and anticorrossive paint outside. The Pipes should be tested as per IS 3589/1966. The Welding should be done as per IS 2825-1969. The thickness of flanges should conform to IS 6392-1971. The specials should conform to ANSI 16.9-with all lead and lift complete & as directed by engineer-in-charge.For delivery side :Minimum 150 mm dia or suitable size flanged pipes.

20

-

90580

... More
-do- Minimum 100mm dia 'B' class GI pipe of TATA or any other approved make for connecting outlet of pressure releif valve to jackwell - with all lead and lift complete & as directed by engineer-in-charge

50

-

37650

... More
-do- Approximate 150 x 600 mm or suitable size flanged concentric reducers -with all lead and lift complete & as directed by engineer-in-charge

2

-

25518

... More
Delivery Manifold :Supply & delivery at site brand new best indepenous make M.S. pipe manifold of 8mm wall thickness and 600mm dia- with all lead and lift complete & as directed by engineer-in-charge

50

-

349800

... More
Minimum 600x600x100mm dia or suitable size flanged Tee with radial branch for installing pressure relief valve - with all lead and lift complete & as directed by engineer-in-charge.

1

-

35467

... More
Minimum 600X600x100 mm dia or suitable size flanged Tee with radial branch- with all lead and lift complete & as directed by engineer-in-charge

2

-

78564

... More
Minimum 600 mm dia MS blank flange of thickness as per IS- with all lead and lift complete & as directed by engineer-in-charge

1

-

9525

... More
For suction side: Minimum 200 mm dia or suitable size flanged pipes - with all lead and lift complete & as directed by engineer-in-charge

20

-

104360

... More
Minimum 200 mm dia 90 deg bend - with all lead and lift complete & as directed by engineer-in-charge

2

-

13156

... More
Minimum 200 x 150 mm or suitable size flanged eccentric reducers - with all lead and lift complete & as directed by engineer-in-charge.

2

-

28074

... More
Minimum 200 mm dia or suitable size HGC/ Ball foot valve of any Board approved make with all lead and lift complete & as directed by engineer-in-charge.

2

-

330000

... More
Dismantling joint:Providing, installing at site of works and testing Dismantling joints in pump delivery pipe line complete, suitable for following specifications and confirming to detailed specifications.a) Diameter -150 mm,b) Working pressure -16 kg/cm2 - with all lead and lift complete & as directed by engineer-in-charge

2

-

80216

... More
Sluice valve :Supply, & delivery of resilient sealed soft sealing sluice valves with body, bonnet of ductile iron of Grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of Vacuum tight and 100% leak proff with face dimensions as per BS 5163-89/ IS 14846-2000/ DIN3202 F4\f5 . The stem Sealing should be with Torodial sealing rings ( Minimum 2 O-rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The Valves shall be supplied with suitable size galvanised bolts and nuts of requied numbers of GKW/KITO/NLXO/TECHMAN any other equivalent international approved brand -a)Diameter -150 mm,b) Working pressure -16 kg/cm2, Material of construction:Body : Ductile cast iron grade GGG50 / SG iron 500/12, Disc: Ductile cast iron grade GGG50 / SG iron 500/12 with valcanised rubber,Shaft : Stainless steel,Coating : Double coating of epoxy liquid lacquer inside and outside of GSK quality-with all lead and lift complete & as directed by engineer-in-charge

3

-

64431.51

... More
-do- 100mm dia sluice valve without actuator -with all lead and lift complete & as directed by engineer-in-charge

1

-

12278.07

... More
Ductile Iron check valves without damper arrangement: DI Double flanged tilting disk swing check valves with slanted seat or with stright disc with metallice corrosion proff and wear resistant seal faces with nickel overlay micro finished with body and disc in DI grade GGG50 shaft of stainless steel and bearing of zinc free bronze and surface protection with epoxy liquid of GSK quality a)Diameter -150 mm,b)Working pressure -16 kg/cm2,Material of construction:Body : Ductile cast iron grade GGG50 / SG iron 500/12, Disc:Ductile cast iron grade GGG50 / SG iron 500/12 with valcanised rubber,Shaft : Stainless steel,Coating :Double coating of epoxy liquid lacquer inside and outside of GSK quality-with all lead and lift complete & as directed by engineer-in-charge

3

-

77669.94

... More
Pressure guage:Supply and delivery at site any Board approved make glycerene filled Stainless steel pressure gauge of 150mm dia suitable for the above pumpsets with nipple, stop cock & two way cock for cleaning & necessary length of copper tubing suitable for mounting on the delivery of pump with all lead and lift complete & as directed by engineer-in-charge

3

-

6000

... More
CONTROL SWITCH GEAR PANELS :Supply and delivery at site brand new any Board approved make floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 440 volts AC supply fitted with the following,450 Amps MCCB with current setting range of 400-630 Amps of any other Board approved make of 50 kA breaking capacity with U/V release, shunt release and suitable thermal release -3 Nos,3 No. Micro processor based Earth leakage relay with resin cast CBCT of Proke's dv's /or any Board approved make, U/V/O/V numeric relay with negative phase sequence protection of Proke's dv's /or any other Board approved make or equivalent- 3 Nos,Phase indicating lamps with switches of any Board approved make- 3 sets,Panel mounting version digital Micro processor based type Multi function meter for measuring current, Voltage, P.F, energy etc., of any Board approved make or equivalent. With RS 485 port- 3 Nos,MS air insulated bus bar chamber with 4 Nos 800 Amps 25 MVA Air insulated bus bar made of high conductivity, high strength aluminium alloy complying with the requirements of grade E91 E of IS 5082, suitably braced with non-hygroscopic SMS supports. Provision shall be made in the bus bar chamber for 3 incoming and 9 outgoing feeders. The bus bar chamber should be of adequate capacity to handle the incoming and out-going cables and for fixing the switchgears as per requirement-1 No,500 Amps load break switch unit conforming to the latest ISS for Motor circuit of any Board approved make. 3 No,160 Amps TPN switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for Capacitor circuit of any Board approved make. 3 No,32 Amps DP load break heavy duty switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for lighting circuit of any Board approved make. 3No,Set of cable entries and terminals suitable for numbers, type and size of aluminium conductor power cables, etc,2 nos. of Aux. relay VAA-33 for alarm and trip system of WTI and OTI for each transformer.NOTE:1) The panel board shall be complete with all other required fittings, and shall be fabricated using 2mm thick sheet steel and wiring shalll be done using suitable size copper cable/copperwire painted with two coats of a highly corrosion resistant primer applied wet on wet and a finishing coat of synthetic enamel paint of the ash greay shade,2) H.R.C. fuse link rated not less than 1.5 times the rated current of the capacitor bank shall be provided in the suitable Amps capacity switch fuse unit for capacitor circuit.,3) The internal wiring shall be done using adequate size insulated electro tinned copper strip or cable of 1.1 KV grade,4) Any discrepancies are noticed apart from tender specification, suitable action as per tender condition will be taken against the tenderer including black listing of the tenderer,5) The Bus bar chamber should be of adequate size to accommodate all incoming, outgoing cables and required switchgears,6) The internal wiring shall be done using adequate size insulated electro tinned copper strip or cable of 1.1 KV grade,7) Any discrepancies are noticed apart from tender specification, suitable action as per tender condition will be taken against the tenderer including black listing of the tenderer.8) The Bus bar chamber should be of adequate size to accommodate all incoming, outgoing cables and required switchgears - with all lead and lift complete & as directed by engineer-in-charge.

1

-

463016

... More
11 kV group VCB Panel-11KV SWITCH GEAR PANEL:( 1 incoming breaker ,3 Nos of outgoing load break switch) Supply and delivery at site brand new any Board approved make 11 kV, 350 MVA weather proof outdoor KIOSK with IP54 or better protection grade with 3ph ,50 cycle VCB panel conforming to IEC-56 suitable for outdoor installation with incorporating the following accessories including loading & unloading, Transportation. Necessary adopter panel shall be supplied along with breaker panel-1 No of incoming Breaker panel consiting of 1 No. of 11kV TP Vacuum circuit breaker, horizontal drawout type suitable for rated current 800A and short time rating of 25 kA for 3 seconds of any Board approved make fitted with the following 1 No. of 230 volts AC 50Hz or 110 V D.C.universal motor charged spring closing mechanism,1 No. of mechanical on/off indicator,1 No. of 110VDC closing coil,1 No. of 110VDC shunt trip,1 No. of close/trip control switch of Alstom make,1 set of space heaters with switch,1 No. of Local/remote selector switch,1 set of castell type mechanical interlocks,1 No. of mechanical Stroke counter,1 No. of 15A, 230V, AC SP socket with switch,1 set of Red/Green indicating lamps for circuit breaker on/off indication of LED type of Board approved make,1 No. of amber lamp for trip on fault indication of LED type of Board approved make,1 No. of white lamp with push button for on demand trip circuit healthy indication of LED type of Board approved make,1 No. of Blue lamp for spring charged indicator of LED type,1 No. of panel illuminating lamp with door limit switch of Board approved make,3 Nos. of Resin cast type twin secondary current transformers conforming to IS 2705, ratio 100/5-5A , class 5P10/class 1.0 accuracy with 15 VA burden for protection and class 1.0 accuracy for metering suitable to withstand short time rating of 25 KA for 3 seconds,3 No. Single Ph, resin cast drawout type potential transformer conforming to IS 3156 ratio 11 KV/ /3 /110V/ /3 Class 0.50 accuracy, 100VA Ph burden, complete with HT and LT fuses and connected to incoming side of the breaker and to the common bus,3 Nos. Terminal connectors for CT's,3 Nos. Terminal connectors for PT's,3Nos of Flexible connectors for connection between breaker & CT's,1set of 6N/O +6N/C spare auxiliary contactors,1 No. of Digital type any Board approved make Ammeter to read R, Y, B, phase currents,1 No. of Multi function meter for mearuement of current , voltage, P.F, KWH, KVAR etc., of any approved make or equivalent with RS 485,1 No. of Electronic type, Trivector meter of class 0.2 accuracy with RS 485 port,1 No. Numerical U/V/O/V relay with negative phase sequence protection,1 No. High speed numerical master tripping relay, 1 No. Trip circuit supervision relay,1 No of Numerical overcurrent and Earthfault relay,4 Nos. of 1 foundation bolts,12 window annuciator panel for braker on/ off/ trip/ healthy / relays trip etc,3 Nos of Outgoing Breaker panel with necessary interlocks each comprising of 3 Nos of load break switch Panel,Supply, erection, electrification and commissioning at site brand new any Board approved make load break switch panel suitable for out door unit for operating on 11 kV , 50 Hz 3 phase AC supply. The panelshall consists of the following equipments as details below,a) On load 630 amps air break switch with fuse trip mechanism and tripping circuit suitable for 3 phase, 11 kV, 50 Hz AC supply,b) Suitable capacity HRC fuses with trip arrangements,c) Bus bar of adquate capacity,d) Panel shall be provided adequate space for accomadation of incoming and outgoing cables,NOTE:-1. The vaccum circuit breaker is required for installation in the solidly earthed system 3 phase 50 Hz 11 KV AC supply.2. The auxiliary switches with minimum no. of 10 normally opened and 10 normally closed contacts for indication control interlock with Isolator protection etc., shall be provided,3. The breaker is required for installation at a site whose altitude does not exceed 900 mtrs. & the maximum ambient air temperature does not exceed 45 degree C.4. The equipments should also include suitable size 33KV panel to mount volt meter, Ammeter frequency meter, Kilowatt hour meter protective relays suitable control wiring from CTs, PTs, and switchgear should be brought to the panel, which is to be erected in the pump house.5. The tenderer should calculate the fault level as per the single line diagram furnished and propose the vacuum circuit breaker accordingly.CODE & STANDARDS:Vacuum circuit breaker IS 13118-1991, 2516 BS 5311 & IEC 56, Panel IS 3427 1969,Current Transformer IS 2705 1981.Voltage Transformer IS 3156 1978 - with all lead and lift complete & as directed by engineer-in-charge.

1

-

817600

... More
11 KV GANG OPERATED DISCONNECTING SWITCHES:Supply and delivery at site brand new Best indegeneous make triple pole horizontal type suitable for outdoor installation air break gang operated off load isolator with earth blade 11 KV 400 Amps. 250 MVA triple pole, gang operated three insulator stock per pole, tilting type double break per phase air break isolator,Switch suitable for operation 3 phase, 50 c/s, 11000 Volts AC supply horizontal mounting type for outdoor installation conforming to the latest ISS 1818 along with all the required accessories. The isolator shall be complete with a) GI operating down pipe complete with handle pad lock key and arching horns, handle earthing wire etc., complete.b) Auxillary switch with 8 auxillary contacts, 4 for making contacts at circuit opening and 4 at circuit closing etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

52635

... More
Digital softstarter:Supply, delivery and commissing at site brand new board approved make or equivalent floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 400/440 volts AC supply fitted with the following: 450 amps MCCB or suitable with fixed and moving contracts fitted with U/V release, shunt release and with suitable thermal release.- 1 Nos,Multi parameter such as current, kwhr, Voltage, KVA reading digital meter of prok devices or any other Board approved make - 1 Nos,Phase indicating lamps with switches of L&T/ BCH/ GE make or any other make approved by the Board - 1 set,The soft starter shall have a facilitty to start the sewage pumpsets by reducing the starting current less than 1.5 to 2 times the full load current. It shall have bulit in facilities such as SPP, Over Voltage, Under voltage, Kick start for pump jam conditions , overload, overcurrent etc., for protection of the pumpsets. The starting current shall be controlled by three phase thyristors. suitable for minimum 250 kW motors,The starter shall be provided with suitable Amps by pass contactor if not built-in in the starter-1 No,The panel shall be provided with cooling fan, louvers with fine mesh to facilitate the cooling of thyristors/ soft starter,The panel should be adequate size to accomadate all incoming, outgoing cable and required switchgear and other accessories,Digital P.F.Meter of any Board approved make,Control supply voltage will be 230 volts AC,Alarm hooter, Suitable size cable gland for I/c & O/G cables,Space heaters with switch, plug and socket, panel lamp working on 230 V A.C,Bus bars should be of Aluminium/Copper,NOTE for soft starters:1.The soft starter shall be rated equivalent to the motor rated power and shall be capable of operating satisfactorily with the motor under the various loading and starting conditions of the motor over the entire range of operation,2. The soft starter shall reduce, the starting current of the motor atleast to 60% of the direct line starting current of the motor. The soft starter shall have facility to further reduce the current upto 50% of the direct on line starting current if the motor and the pump torque speed curve permits,3. The soft starter shall work on the principle of unsaturated core in the working zone and shall not lead to generation of Harmonics.4. Soft starter shall be so rated as to allow two consecutive starts from cold or one hot start per hour.5. Soft starter shall be designed for supply voltage of '+OR -10% AND Frequency Variation of +OR - 3% or a combination of both.6. The winding of the soft starter shall be with insulation class "F" and maximum temp of winding shall be limited to that of class "B".8. The starter shall not contain any active electronic components.9. The starter shall have a built in facility for run bypass so that the incoming voltage to the motor is equal to the supply voltage.10. The Soft starter unit should be Air cooled.11. The soft starter shall be dust and vermin proof and suitable for indoor mounting etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

1405350

... More
Power Capacitors: Supply and delivery at site brand new best indegeneous make 3 phase, 50 c/s 440 volts suitable KVAR All Polypropelene type power capacitor conforming to the latest ISS 2834 suitable for indoor installations at a site whose altitude is 50 -Note:- The capacitor is required to keep the total power factor of the installation at not less than 0.95 lagging - etc with all lead and lift complete & as directed by engineer-in-charge.

324

-

72900

... More
Main side cable:- Supply and delivery at site brand new Iany Board approved make Aluminium standard conductors PVC insulated ,sheathed steel tape/wire armoured, XLPE insulated , PVC tape innersheathed, 1.1 KV class UG Cable conforming to the latest ISS 1554.The length of the cable supplied shall be as per site conditions. The quantity indicated is only approximate and the successful bidder shall measure the quantity required at site before procurement of cable etc with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x 185 sq mm

400

-

434400

... More
Load side cable:- Supply and delivery at site brand new Iany Board approved make Aluminium standard conductors PVC insulated ,sheathed steel tape/wire armoured, XLPE insulated , PVC tape innersheathed, 1.1 KV class UG Cable conforming to the latest ISS 1554.The length of the cable supplied shall be as per site conditions. The quantity indicated is only approximate and the successful bidder shall measure the quantity required at site before procurement of cable etc with all lead and lift complete & as directed by engineer-in-charge. For 3 x 240 Sq mm

150

-

179400

... More
-do- For 3 x 120 Sq mm with all lead and lift complete & as directed by engineer-in-charge.

30

-

18600

... More
11 KV HT XLPE CABLE:Supply and delivery of aluminium XLPE HT cable earthed, glavanised steel flat strip armoured for the purpose of connecting from metering cubical to pole structure and from there to breaker panel of any Board approved make. The length of the cable supplied shall be as per site conditions. The quantity indicated is only approximate and the successful bidder shall measure the quantity required at site before procurement of cable with all lead and lift complete & as directed by engineer-in-charge. For 3 x 120 sqmm

80

-

93760

... More
PRESSURE RELIEF VALVES :Supply, delivery and erection of site brand new DOROT( S-300 series)/BERMAD/ ERHALD/ SINGER make pressure relief valve of 100mm dia with the following specifications (PN 16) 1. Valve should have direct sealing diaphragm activated by line pressure and controlled by 2 way diaphragm operated adjustable pilot valve.2. Valve should be installed on a Tee junction, which should modulates automatically to maintain present inlet pressure and releive the excess pressure out of the network.MATERIAL OF CONSTRUCTION :1) Body and Bonnet - Ductile Iron ISO 1083 Grade 450-10, 2)Diaphragm - Natural rubber (standard).3) Spring - SS 302, 4) Pilot valve - Brass ISO 426, 5) Coating - Electrically applied over baked polyster,6) End connection - Flanges BS or IS,The outlet of pressure sustaining valve should be connected to sump using MS pipes and fittings - with all lead and lift complete & as directed by engineer-in-charge.

1

-

199520

... More
Manufacture, supply and commission Electromagnetic Flow Meter (EMF), for Raw/Pure water with accuracy 0.5% of measured value & protection as per given specifications for Nominal Diameter Flowmeter. Including sensor, transmitter surge arrestor, cable GI duct if suitable size for 25 mtrs. sensor, transmitter surge arrestor, 25 Mtrs / each flow meter, including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes etc., as may be required at site & based on technical specifications below: A) Mandatory Accessories: 1) The sensor should be as per IP-68 protection & with flanges of up to PN 10 rating from CS-1 No. 2) The sensor coil housing shall be IP-68.This protected against external magnetic field. 3) The transmitter shall have one current 4 m A-20 mA output- 4) The current output shall be galvanically / optically isolated. It shall be fitted with switched mode power supply capability 85-260 V & 45-65 Hz to cope with power transients without damage. 5) Signal & power cables shall be of 50 Mtrs length/each. 6) Conduit pipe ( PVC Plumbing schedule 4 ) 25 mm diameter with suitable rating of cable with digging, laying & concealed the duct - 25 mtrs/each. 7) UPS working on 230 V AC, 50 Hz power supply suitable for 12 hrs continuous operation-1 No. 8) Data storage capacity with built in or separate for date time, actual flow rate, totaliser & error messages if any with storage capacity of 120 days at 1 hour interval data logging-1 No. 9) 21",80 column Dot matrix printer of EPSON, WIPRO, or Hewlett Packard make with printer interface unit for printing of stored data as per 8 )-1 No. 10) Proper earthing shall be provided for protection against high voltage surge. 11) Suitable over voltage protection unit for protection of instrument from higher voltage (upto 275 V-300 V AC) -600 mm dia - etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

525000

... More
ERECTION OF CAPACITORS:Formation of suitable CC foundation in CC 1:2:4 using all the required materials such as cement, sand,jelly etc., complete and erection of the capacitor on the above foundation using the required materials etc., complete including the cost of all the materials - ( 3 banks)- etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

5000

... More
INSTALLATION OF STARTERS Formation of suitable foundation CC 1:2:4 using all the required materials such as cement, sand, jelly etc., complete and erection of switch gears and starters on the above foundation using the required materials such as bolts, nuts washers etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

24600

... More
Erection of Control Panel Board (415V) on CC foundation including formation of CC foundation in CC 1:2:4 prop. using all the required materials such as cement, jelly etc., complete including erection of the panel board, on CC foundation using reqired materials such as MS channel bolts, nuts, washers etc., complete. with all lead and lift etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

8200

... More
LAYING OF CABLE: The works shall include digging of trenches size of 0.60 Mtrs. deep & 1.0 Mtrs. wide providing providing sand bedding to the cables laying the cable in trench providing cable marking bricks refilling, consolidation the soil etc., complete including the cost of all the materials required for laying the cable as per IE rules labour etc.,with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x 185 Sqmm 1.1 KV Class cable (mtr of 3 run)

100

-

16300

... More
-do- For 3 x 120 Sqmm 11 KV Class -with all lead and lift complete & as directed by engineer-in-charge.

40

-

6520

... More
LAYING IN G.I. PIPE: Running the cable in 2.9 mm thick suitable size GI pipe above the grand using all the required materials such as GI pipe clamps, bolts, nuts, washers etc., for fixing the GI pipes to the pole including the cost of these mateials labour ,with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x 185 Sqmm 1.1 KV Class cable (mtr of 3 run)

300

-

62400

... More
-do- For 3 x 120 Sqmm 11 KV Class -with all lead and lift complete & as directed by engineer-in-charge.

40

-

8320

... More
Laying of load side cable:- Running the cable in existing ducts including properly securing cable in position etc., complete using all the required materials with all lead and lift complete & as directed by engineer-in-charge. For 3 x 240 Sqmm (mtr of 2 run)

150

-

5700

... More
-do- For 3 x 70 Sqmm 11 KV Class -with all lead and lift complete & as directed by engineer-in-charge.

30

-

1140

... More
Cable Terminations: Termination of cable using Alluminium/copper lugs to the terminal end for solderless crimping to aluminimum conductors by adopting crimping tool with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x185 Sqmm 1.1 KV Class cable (main side cable)

27

-

9153

... More
'-do- For 3 x 240 Sqmm 11 KV Class cable (load side cable)-with all lead and lift complete & as directed by engineer-in-charge.

24

-

11496

... More
-do- For 3x 120 Sqmm 1.1 KV Class cable (capacitor cable)-with all lead and lift complete & as directed by engineer-in-charge.

6

-

1182

... More
Erection of pumpsets: Erection of the raw water submersible pumpset on the floor with necessary formation of machine foundation using suitable size MS channels, cross girder, plate girder, nuts & bolts, washers etc., complete. Lowering of Pumpsets, delivery pipe assembly into Jackwell and fixing of pumpset in position true to line vertically, maintaining the alignment, dynamic balancing and linking to delivery line proper packing of the hole after laying the pipe with CC 1:2:4 etc., complete. The work also includes providing necessary anti vibration mounts, Bolts, nuts fixing of sutiable clamps etc., including necessary civil works. The pumpset shall be mounted vertically and the discharge head of the pumps shall be connected to the the pipes, valves and delivery manifold which shall be mounted in the ground floor of pumphouse. The work includes erection of lifting chain and other accessories of the pumpset etc.,which are required for operation of the pumpset satisfactorily - with all lead and lift complete & as directed by engineer-in-charge.

3

-

60000

... More
LAYING AND JOINTING OF MS PIPES AND SPECIALS:Laying and jointing of MS pipes and specials for delivery connections of the pump using suitable size bolts, nuts, packing etc., complete including fixing of all types of valves, gauges, strainers, delivery & suction manifold. The work shall include providing pipe supports, thrusts block in CC 1:2:4 prop., wherever necessary upto the end of the delivery manIfold, using all the requied materials such as sand, cement jelly including making holes in sump, pump house for laying suction and devliery pipes, packing of holes with CC 1:2:4 etc., complete. (all lead and lift) (NOTE: The tenderer should furnish the layout drawing showing the position of valves, Tees, Pipes, providing for future pumpsets etc., and obtain approval from the Chief Engineer before taking up erection work) with all lead and lift complete & as directed by engineer-in-charge.

1

-

10000

... More
Cable End Seals:- Supply and fixing of 1.1 KV Indoor and outdoor type RAYCHEM/M SEAL /or any other Board approved make heat shrinkable /Push On type cable end seals with all required materials including copper lugs and terminals.,etc.,complete. Suitable with all lead and lift complete & as directed by engineer-in-charge. For 3 X 120 sqmm, 11 KV XLPE cable, outdoor earthed type

1

-

5470

... More
-do- For 3 X 120 sqmm, 11 KV XLPE cable indoor earthed type - with all lead and lift complete & as directed by engineer-in-charge.

12

-

62208

... More
Pumps: Supply & delivery at site brand new, best efficient make approved by the Board horizontal split case centrifugal pump conforming to the latest IS 1520 & IS 5120 and the following description a) Duty condition: Capable of delivering 35.97 LPS of Treated water containing turbidity upto 10 ppm against a total head of 35 m, b) Speed: Duty condition should be met at 1450 RPM, c) Shutt off head: Min 110 % & Max 130 % of the specified head.d) Material of construction: 1)Casing- Cast Iron, 2)Impellor - CF 8M, 3)Shaft- Stainless steel shaft- SS 410,4) Stuffing Box- Graphite Asbestos packing, 5) Wear Rings- CF 8M, 6)Gland- Cast Iron, 7)Inter Stage Ring- Phosphor Bronze, 8) Shaft Sleeve & Nuts- SS 410, 9)Neck ring- CF 8M, e)Driving end bearing: Grease lubricated roller/ball/ journal bearing, f) Non driving end bearing: Grease lubricated deep groove ball bearing as well as journal bearing or deep groove ball bearng only, g)Coupling: Suitable size vibration proof flexible coupling with coupling guard, as recommended by the manufacturer of pump, for coupling to motor, h)Base plate: Heavy duty common CI/MS base plate for pump and motor wth suitable I section girders, channels, plates, bolts & nuts etc. NOTE: (1) The duty condition of the pump should be at BEP or to the left of the BEP.(2) The pump is required to work at an altitude of 800m. above MSL and at a max. ambient temperature of 45 degree C,(3) The Board reserves the right to select any stipulated make of pump - etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

200000

... More
Motor: Supply & delivery at site brand new, best efficient minimum 30 HP or suitable HP ABB/Marathon/Jyoti/Bharath Bijlee /CGL /or equivalent make Horizontal Foot mounted TEFC, squirrel cage induction 1500 RPM (syn)motor for continuous duty conforming to IS 4691 and IS 325 for operation on 3 ph, 50 Hz. 430 volts,a) Protection: IP 55,b) Insulation: `F' class, e) Ambient temperature: Upto 45 Degree C,d) Cushion: 15 % more than maximum power required by the pump and capable of providing rated output upto + or - 10% voltage variation and/or + or - 3% frequency variation or combination of Both e) Driving end bearing: Grease lubricated roller bearing f) Non driving end bearing: Grease lubricated ball bearing - etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

250000

... More
DOUBLE FLANGED PIPES & SPECIALS :Supply & delivery at site brand new best indegenous make double flanged Mild Steel 8.00 mm thick pipes & specials suitable for test pressure equivalent to twice the working pressure. The pipes should be coated with food grade epoxy primar coat of 45 microns thick and two coats of food grade nonphelic/nontoxic Berger/ poladian/ Akzo Noble make epoxy paint of 80 microns thick each coat inside and anticorrossive paint outside. The Pipes should be tested as per IS 3589/1966. The Welding should be done as per IS 2825-1969. The thickness of flanges should conform to IS 6392-1971. The specials should conform to ANSI 16.9 -etc with all lead and lift complete & as directed by engineer-in-charge. For Suction Connections: Minimum 150 mm dia or suitable size flanged pipes

15

-

53250

... More
-do- For Minimum 150 mm dia or suitable size flanged 900 Radial Bend - etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

7500

... More
-do- For Minimum 150 mm dia Flanged foot valve - etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

17000

... More
-do- For delivery side :Minimum 150 mm dia or suitable size flanged pipes - etc with all lead and lift complete & as directed by engineer-in-charge.

25

-

88750

... More
-do- For Minimum 50mm dia 'B' class GI pipe of TATA or any other approved make for connecting outlet of pressure releif valve to jackwell - etc with all lead and lift complete & as directed by engineer-in-charge.

80

-

41120

... More
-do- Minimum 150x100mm or suitable size flanged reducer -etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

7000

... More
-do- For Delivery Manifold :'Supply & delivery at site brand new best indegenous make M.S. pipe manifold of 8mm wall thickness and 300 mm dia.-etc with all lead and lift complete & as directed by engineer-in-charge.

50

-

190000

... More
-do- For Minimum 300x 300x100mm dia or suitable size flanged Tee with radial branch for installing pressure relief valve - etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

4500

... More
-do- For Minimum 300X 300x 100 mm dia or suitable size flanged Tee with radial branch - etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

13000

... More
-do- For Minimum 300 mm dia MS blank flange of thickness as per IS- etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

6500

... More
Dismantling joint - Providing, installing at site of works and testing Dismantling joints in pump delivery pipe line complete, suitable for following specifications and confirming to detailed specifications-a) Diameter -100 mm b)Working pressure -10 kg/cm2 -etc with all lead and lift complete & as directed by engineer-in-charge.

4

-

30000

... More
Sluice valve: Supply, & delivery of resilient sealed soft sealing sluice valves with body, bonnet of ductile iron of Grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of Vacuum tight and 100% leak proff with face dimensions as per BS 5163-89/ IS 14846-2000/ DIN3202 F4\f5 . The stem Sealing should be with Torodial sealing rings ( Minimum 2 O-rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The Valves shall be supplied with suitable size galvanised bolts and nuts of requied numbers of GKW/ KITO/NLXO/TECHMAN any other equivalent international approved brand.a) Diameter -100 mm,b)Working pressure - 10 kg/cm2,Material for component Parts Body and bonnet : Ductile cast iron of grade GGG50,Stem : AISI 410 Stainless Steel IS 6603 Gr. 12 Cr12,Wedge: Ductile iron GGG50 Rubber lined with EPDM,Wedge nut: Bronze,Bolts and nuts: Stainless steel, Bonnet Gasket: EPDM - etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

24313

... More
-do- For 50mm dia Sluice Valve -etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

6522.45

... More
Ductile Iron check valves without damper arrangement: DI Double flanged tilting disk swing check valves with slanted seat or with stright disc with metallice corrosion proff and wear resistant seal faces with nickel overlay micro finished with body and disc in DI grade GGG50 shaft of stainless steel and bearing of zinc free bronze and surface protection with epoxy liquid of GSK quality.a) Diameter - 100 mm,b) Working pressure-10 kg/cm2,Material of construction: Body : Ductile cast iron grade GGG50 / SG iron 500/12,Disc: Ductile cast iron grade GGG50 / SG iron 500/12 with valcanised rubber,Shaft : Stainless steel,Coating : Double coating of epoxy liquid lacquer inside and outside of GSK quality --etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

29926.44

... More
Pressure Gauge :Supply and delivery at site Air master/Gurusons/Forbes Marshal make glycerene filled Stainless steel pressure gauge of 50mm dia suitable for the above pumpsets with nipple, stop cock & two way cock for cleaning & necessary length of copper tubing - etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

4000

... More
11 KV GANG OPERATED DISCONNECTING SWITCHES:Supply and delivery at site brand new Best indegeneous make triple pole horizontal type suitable for outdoor installation air break gang operated off load isolator with earth blade 11 KV 400 Amps. 250 MVA triple pole, gang operated three insulator stock per pole, tilting type double break per phase air break isolator,Switch suitable for operation 3 phase, 50 c/s, 11000 Volts AC supply horizontal mounting type for outdoor installation conforming to the latest ISS 1818 along with all the required accessories. The isolator shall be complete with a) GI operating down pipe complete with handle pad lock key and arching horns, handle earthing wire etc complete,b) Auxillary switch with 8 auxillary contacts, 4 for making contacts at circuit opening and 4 at circuit closing - etc with all lead and lift complete & as directed by engineer-in-charge. (Each consisting of set of 3 Nos)

1

-

15637

... More
Horn Gap Fuses : Supply and delivery at site brand new best indegeneous make horizontal mounting suitable for outdoor installation 11 KV, 3 phase, 50 c/s 200 amps 250 MVA capacity high voltage horn gap fuse units with suitable capacity fuse along with operating hickery rod for operations of fuses from ground etc complete with all the standard fittings-etc with all lead and lift complete & as directed by engineer-in-charge. (Each consisting of set of 3 Nos)

1

-

827

... More
CONTROL SWITCH GEAR PANELS:Supply and delivery at site brand new any Board approved make floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 440 volts AC supply fitted with the following:125 Amps MCCB with current setting range of 50-125Amps of any other Board approved make of 50 kA breaking capacity with U/V release, shunt release and suitable thermal release -1 Nos,1 No. Micro processor based Earth leakage relay with resin cast CBCT of Proke's dv's /or any Board approved make, Micro processor based U/V/O/V relay with negative phase sequence protection of Proke's dv's /or any other Board approved make or equivalent- 1 Nos,Phase indicating lamps with switches of any Board approved make- 1 sets,Panel mounting version digital Micro processor based type Multi function meter for measuring current, Voltage, P.F, energy etc., of any Board approved make or equivalent.- 1 Nos.MS air insulated bus bar chamber with 4 Nos 200 Amps 25 MVA Air insulated bus bar made of high conductivity, high strength aluminium alloy complying with the requirements of grade E91 E of IS 5082, suitably braced with non-hygroscopic SMS supports. Provision shall be made in the bus bar chamber for 1 incoming and 5 outgoing feeders. The bus bar chamber should be of adequate capacity to handle the incoming and out-going cables and for fixing the switchgears as per requirement-1 No,Heavy duty triple pole change over fuse switch of 100 Amps, comprising of two switches mounted on common chasis, complete with handle assembly door interlock and pad locking arrangement with mechanical linkage shorting links and Suitable Amps, HRC fuses in sheet metal enclosure of board approved make conforming to the latest IS 4064 Controls and switchegear make - 1No,32 Amps TPN switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for Capacitor circuit of any Board approved make. 2 No,32 Amps DP load break heavy duty switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for lighting circuit of any Board approved make. 2 No.Set of cable entries and terminals suitable for numbers, type and size of aluminium conductor power cables, etc.2 nos. of Aux. relay VAA-33 for alarm and trip system of WTI and OTI for each transformer,Note:1) The panel board shall be complete with all other required fittings, and shall be fabricated using 2mm thick sheet steel and wiring shalll be done using suitable size copper cable/copper wire painted with two coats of a highly corrosion resistant primer applied wet on wet and a finishing coat of synthetic enamel paint of the ash greay shade.2) H.R.C. fuses links suitable for motor duty shall be provided to 500 Amps change over switch fuse unit.3) H.R.C. fuse link rated not less than 1.5 times the rated current of the capacitor bank shall be provided in the suitablecapacity switch fuse unit for capacitor circuit,4) The internal wiring shall be done using adequate size insulated electro tinned copper strip or cable of 1.1 KV grade.5) Any discrepancies are noticed apart from tender specification, suitable action as per tender condition will be taken against the tenderer including black listing of the tenderer.6) The Bus bar chamber should be of adequate size to accommodate all incoming, outgoing cables and required switchgears - etc complete with all the standard fittings-etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

68500

... More
Digital softstarter:Supply, delivery and commissing at site brand new board approved make or equivalent floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 400/440 volts AC supply fitted with the following: 320 amps MCCB or suitable with fixed and moving contracts fitted with U/V release, shunt release and with suitable thermal release.- 1 Nos,Multi parameter such as current, kwhr, Voltage, KVA reading digital meter of prok devices or any other Board approved make - 1 Nos,Phase indicating lamps with switches of L&T/ BCH/ GE make or any other make approved by the Board - 1 set,The soft starter shall have a facilitty to start the sewage pumpsets by reducing the starting current less than 1.5 to 2 times the full load current. It shall have bulit in facilities such as SPP, Over Voltage, Under voltage, Kick start for pump jam conditions , overload, overcurrent etc., for protection of the pumpsets. The starting current shall be controlled by three phase thyristors.The starter shall be provided with 63Amps by pass contactor if not built-in in the starter-1 No,The panel shall be provided with cooling fan, louvers with fine mesh to facilitate the cooling of thyristors/ soft starter.The panel should be adequate size to accomadate all incoming, outgoing cable and required switchgear and other accessories.Digital P.F.Meter of any Board approved make,Control supply voltage will be 230 volts AC,Alarm hooter, Suitable size cable gland for I/c & O/G cables,Space heaters with switch, plug and socket, panel lamp working on 230 V AC,Bus bars should be of Aluminium/Copper,NOTE:1.The soft starter shall be rated equivalent to the motor rated power and shall be capable of operating satisfactorily with the motor under the various loading and starting conditions of the motor over the entire range of operation.2. The soft starter shall reduce, the starting current of the motor atleast to 60% of the direct line starting current of the motor. The soft starter shall have facility to further reduce the current upto 50% of the direct on line starting current if the motor and the pump torque speed curve permits.3. The soft starter shall work on the principle of unsaturated core in the working zone and shall not lead to generation of Harmonics.4. Soft starter shall be so rated as to allow two consecutive starts from cold or one hot start per hour.5. Soft starter shall be designed for supply voltage of '+OR -10% AND Frequency Variation of +OR - 3% or a combination of both.6. The winding of the soft starter shall be with insulation class "F" and maximum temp of winding shall be limited to that of class "B".7. The soft starter shall be housed in a sheet steel enclosure of thickness not less than 14 guage and painted with corrosion resistive paint such as epoxy of Polyurethene. The degree of protection shall be IP 41.8. The starter shall not contain any active electronic components.9. The starter shall have a built in facility for run bypass so that the incoming voltage to the motor is equal to the supply voltage.10. The Soft starter unit should be Air cooled.11. The soft starter shall be dust and vermin proof and suitable for indoor mounting-etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

200000

... More
Power Capacitors: Supply and delivery at site brand new best indegeneous make 3 phase, 50 c/s 440 volts 2 banks of 13 KVAR or suitble KVAR Alluminium Polypropelene type power capacitor conforming to the latest ISS 2834 suitable for indoor installations at a site whose altitude is 50,Note:- The capacitor is required to keep the total power factor of the installation at not less than 0.95 lagging-etc with all lead and lift complete & as directed by engineer-in-charge

26

-

16640

... More
TWO POLE STRUCTURE: Fabrication supply and delivery at site brand new best indegeneous make pole structure comprising of 175 mmx90 mm I-Section girders 9 m long,75mm x 40 mm size channels, 35 x 35 x 5 mm braces of required Nos., 11 KV pin insulators, 11 KV strain insulator The work shall include design fabrication, supply and installation of out door sub-station structure as per the layout drawing enclosed which includes the following.a) Fabrication of the sub-station structure using the materials like galvanised mild steel section, channels, angles, flats, plates, rounds etc., for supporting isolator drop out lift of fuses. 11 KV strain insulators, 11 KV support insulators for establish,b) Installation of the sub-structure on CC foundation including providing concrete foundation in CC 1:2:4 using all the required materials such as 20 mm size jelly, sand, cement etc,c) Supply and fixing of 11 KV support insulators using all the required materials.d) Supply and fixing of 1.5 inch dia IPS aluminium tube for bus conductors or by using Rabbit ACSR conductors using all the required materials, with provision for extending the bus bar on both sides for future expansion.e) Fixing of disconnecting switches and drop out lift of fuse unit using all the required materials.f) Providing jump connections using Rabbit ACSR between the structure and HT bushings of the power transformer.g) Providing galvanised MS covers for static shield of the sub-station switch yard.NOTE:1) The work shall be complete enclosed using all the required materials.2) The following shall form the basis of design:a) The structure shall be designed so as to enable the structure to withstand without any injury or permanent deflection, test loads, equivalent to the respective working loads multipled by the fator of safety of 25.b) The ratio of effective length to the appropriate radius of gyration shall not exceed the following. i) For members having calculated stresses 200 ii) Redundents 250,3) The steel used for fabrication shall be of mild steel quality confirming to IS 226.4)Strain plates of suitable dimensions for engaging the U clamps of the strain insulator assembly shall be adequate strength,5) Necessary holes, U bolts shakles etc., for taking the ground wire clamps handling devices shall be provided.6) All the joints of the structure shall be made by using standard galvanised 16 mm dia bolts and nuts spring washers (3.5 to 4 mm thick squate in section and electric galvanised) -etc with all lead and lift complete & as directed by engineer-in-charge

1

-

38900

... More
Main side cable:- Supply and delivery at site brand new any Board approved make 3 1/2 x 75 sqmm Aluminum conductors PVC sheathed 1.1 KV class UG Cable conforming to the latest ISS 1554 -etc with all lead and lift complete & as directed by engineer-in-charge

100

-

27000

... More
Load side cable:- Supply and delivery at site brand new Iany Board approved make Aluminium standard conductors PVC insulated ,sheathed steel tape/wire armoured, PVC outer sheated 1.1 KV class UG Cable conforming to the latest ISS 1554--etc with all lead and lift complete & as directed by engineer-in-charge. For 3 x 50Sq mm (load side)

50

-

10200

... More
-do- For 4 x16 Sq mm (for capacitor circuit) - etc with all lead and lift complete & as directed by engineer-in-charge.

20

-

3000

... More
11 KV HT XLPE CABLE:Supply and delivery of aluminium XLPE HT cable earthed, glavanised steel flat strip armoured for the purpose of connecting from metering cubical to pole structure and from there to breaker panel of any Board approved make. The length of the cable supplied shall be as per site conditions. The quantity indicated is only approximate and the successful bidder shall measure the quantity required at site before procurement of cable -- etc with all lead and lift complete & as directed by engineer-in-charge. For 3 x 95 sqmm

50

-

33800

... More
ERECTION OF CAPACITORS:Formation of suitable CC foundation in CC 1:2:4 using all the required materials such as cement, sand,jelly etc., complete and erection of the capacitor on the above foundation using the required materials etc., complete including the cost of all the materials - 2 banks of 80 kVAr - etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

2000

... More
ERECTION OF TRANSFORMER and Sub station:Erection of substation structure fabricated out of beams erection of substation equipments such as two pole structure, iron channels , strain insulator, pin insulators, fixing of Isolators with earth switch, lighting arrestor ACSR, bus conductor etc., complete including painting the structure with best quality weather proof approved paint over a coat of anticorrosive primer, providing and fixing of anticlimbing device danger board, etc., complete including providing necessary foundation for the pole structure in CC 1:3:6 including the cost of all materials etc., complete. including erection of load break switch panel and metering cubicle panels with necessary foundation and other equipments which are not specifically indicated with all lead and lift etc., complete. Formation of suitable elevated platform in size stone masonry in CM 1:6 using all the required materials such as cement, sand, jelly etc., complete and with MS rail embeded on the top of the platform, hoisting the load break switch panels, transformer etc for the erection on the above platform and erection of the panels on the platform including the cost of all the materials required labour etc., complete with supply and spreading of 40 mm down size jelly all round the substation- etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

54331

... More
INSTALLATION OF STARTERS:Formation of suitable foundation CC 1:2:4 using all the required materials such as cement, sand, jelly etc., complete and erection of switch gears and starters on the above foundation using the required materials such as bolts, nuts washers - etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

16400

... More
Erection of Control Panel Board on CC foundation including formation of CC foundation in CC 1:2:4 prop. using all the required materials such as cement, jelly etc., complete including erection of the panel board, on CC foundation using reqired materials such as MS channel bolts, nuts, washers .- etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

8200

... More
Erection of pumpsets:-Formation of suitable block machine foundation in CC 1:2:4 confirming to the latest ISS 2974 using all the required materials such as cement, sand, jelly etc., complete including necessary earth work refilling curing etc., complete. Erection of the pumpset mounted on the common baseplate on the above foundation using the required material such as foundation bolts, key locks, self interlocking bolts, washer etc., complete levelling, aligning of the pumpsets on the foundation grounding and dynamic balancing using all the required materials including excavation for foundation making pump pits, dewatering - etc with all lead and lift complete & as directed by engineer-in-charge.

2

-

300000

... More
LAYING OF CABLE: LAYING IN TRENCHES:-The works shall include digging of trenches size of 0.60 Mtrs. deep & 1.0 Mtrs. wide providing providing sand bedding to the cables laying the cable in trench providing cable marking bricks refilling, consolidation the soil etc., complete including the cost of all the materials required for laying the cable as per IE rules labour etc with all lead and lift completeetc with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x 75 Sqmm 1.1 KV Class cable

75

-

10350

... More
-do- For 3 x 95 Sqmm 11 KV Class -etc with all lead and lift complete & as directed by engineer-in-charge.

30

-

4140

... More
LAYING IN G.I. PIPE: Running the cable in 2.9 mm thick suitable size GI pipe above the grand using all the required materials such as GI pipe clamps, bolts, nuts, washers etc., for fixing the GI pipes to the pole including the cost of these mateials labour etc with all lead and lift complete & as directed by engineer-in-charge -For 3.5 x 75 Sqmm 1.1 KV Class cable

25

-

5200

... More
-do- For 3 x 95 Sqmm 11 KV Class -etc with all lead and lift complete & as directed by engineer-in-charge.

20

-

4160

... More
Laying of load side cable:- Running the cable in existing ducts including properly securing cable in position etc., complete using all the required materials etc with all lead and lift complete & as directed by engineer-in-charge. For 3 x 50 Sqmm (load side cable)

30

-

1140

... More
-do- For 4 x 16 Sqmm (Capacitor cable)-etc with all lead and lift complete & as directed by engineer-in-charge.

10

-

360

... More
Cable Terminations: Termination of cable using Alluminium/copper lugs to the terminal end for solderless crimping to aluminimum conductors by adopting crimping tool etc with all lead and lift complete & as directed by engineer-in-charge. For 3.5 x50 Sqmm 1.1 KV Class cable (main side cable)

4

-

248

... More
-do- For 3 x 70 Sqmm 1.1 KV Class cable (load side cable)-etc with all lead and lift complete & as directed by engineer-in-charge.

4

-

248

... More
-do- For 3 x 6 Sqmm 1.1 KV Class cable (capacitor cable)-etc with all lead and lift complete & as directed by engineer-in-charge.

4

-

24

... More
LAYING AND JOINTING OF MS PIPES AND SPECIALS:Laying and jointing of MS pipes and specials for suction & delivery connections of the pump using suitable size bolts, nuts, packing etc., complete including fixing of all types of valves, gauges, strainers, delivery & suction manifold. The work shall include providing pipe supports, thrusts block in CC 1:2:4 prop., wherever necessary upto the end of the delivery manIfold, using all the requied materials such as sand, cement jelly including making holes in sump, pump house for laying suction and devliery pipes, packing of holes with CC 1:2:4 -NOTE: The tenderer should furnish the layout drawing showing the position of valves, Tees, Pipes, providing for future pumpsets etc., and obtain approval from the Chief Engineer before taking up erection work - etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

18200

... More
PRESSURE RELIEF VALVES :Supply, delivery and erection of site brand new DOROT(S-300 series)/BERMAD/ ERHALD/ SINGER make pressure relief valve of 50mm dia with maximum permisable pressure 6 Kg/cm2 with the following specifications (PN 10) 1)Valve should have direct sealing diaphragm activated by line pressure and controlled by 2 way diaphragm operated adjustable pilot valve.2) Valve should be installed on a Tee junction, which should modulates automatically to maintain present inlet pressure and releive the excess pressure out of the network.MATERIAL OF CONSTRUCTION :1) Body and Bonnet - Ductile Iron ISO 1083 Grade 450-10. 2)Diaphragm - Natural rubber (standard).3) Spring - SS-302, 4)Pilot valve - Brass ISO 426, 5)Coating - Electrically applied over baked polyster. 6)End connection - Flanges BS or IS.The outlet of pressure sustaining valve should be connected to sump using MS pipes and fittings - etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

128500

... More
Servicing and commissioning: The pumpsets along with all other elecrical equipments shall be serviced and commissioned in the presence of the Engineer-in-charge of work including trail running for a period of 90 days. The work shall include the following, Providing operating and maintenance manuals of the pumps and allied equipments to the operating personnel.Giving trail run of the pumpsets for a period of 90 days from the date of successful commissioning.The contractor should employ personnel to operate & maintain the pumpset and accessories during the trial run period and should train the Board/Municipal Staff to operate the pumpsets.NOTE: 1)The energy and water will be provided by the Board free of cost. 2) The pumpsets along with all the electrical equipments shall be commissioned only when the performance of switch gears, relays are wittnessed by the Executive Engineer in charge of the work and Asst. Executive Engineer (Electrical) of the Board - etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

36000

... More
Chain linked wire fencing:- Supply and providing chain linked wire fencing for 11 kV transformer sub-station. The chain linked fencing should be with 2"x2"x8 SWG wire welded to angle iron frames of size 2.5 Mx2.5M using angle of 50x50x6MM. The frame be fixed to the supporting channels spaced at 2.5M of size 100x50mm 3.1 M height fixed in CC (1:2:4) at bottom etc.,including cost of all materials transportation and labour for fixing, silver painting etc., complete with door of 2.5M size at suitable places- Chain linked fencing shall be erected upon size stone masonry structure. The work includes providing & constructing granite/trap/basalt size stone masonry (0.45m wide, for aheight of 0.30m) in foundation cement mortor 1:6 stone hammer dressed in courses not less than 20 cm high, bond stones at two m apart and over plain cement concrete of mix M15 with OPC cement @240kgs, with 40mm and down size graded granite metal coarse aggregates @0.878 cum and fine aggregates @ 0.459 cum machine mixed concrete laid in layers not exceeding 15 cms thick, well compacted, in foundation and plinth for a thickness of 0.15cm for foundation and 0.10 for coping including cost of all materials, labour, HOM of machinery, curing etc with all lead and lift complete & as directed by engineer-in-charge.

10

-

33000

... More
Cable End Seals:- Supply and fixing of 1.1 KV Indoor and outdoor type RAYCHEM/M SEAL /or any other Board approved make heat shrinkable /Push On type cable end seals with all required materials including copper lugs and terminals., etc with all lead and lift complete & as directed by engineer-in-charge. For 3 X 95 sqmm, 11 KV XLPE cable, outdoor earthed type

1

-

4544

... More
'-do- For 3 X 95 sqmm, 11 KV XLPE cable indoor earthed type -etc with all lead and lift complete & as directed by engineer-in-charge.

3

-

12921

... More
Providing insulating mats with glowing strips for 1100 Volts - etc with all lead and lift complete & as directed by engineer-in-charge.

30

-

55920

... More
FIRE FIGHTING EQUIPMENTS :Supply and delivery at site brand new fire extinguishers consisting of 2 Nos. of 2 kg capacity cylindrical type carbon di-oxide gas pressure type suitable for 25 to 35 feet range operation with initial charge and suitable brackets as per fire extinguishers regulations.- 2 Nos, b) Supplying and fixing of first aid box comprising of the standard medicines to be provided in the first aid box to give first aid treatment - 1 No, c) Providing shock treatment chart on wall with inside plastic sheet cover and ply wood backplate frame work complete.d) Supply one set of fire buckets (4 Nos) with round bottom made of GI sheets 24 SWG 9 ltrs. capacity painted inside white and outside red with a word `fire' on the face of the bucket along with stand to hang the buckets. e) Supplying rubber gloves, electrical quality, tested to 22KV - 1 Pair, f) Supplying and fixing of Danger/No Admission/No Smoking Board made out of MS sheet metal with two coats of non-corrosive enamelled paint -etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

10000

... More
TOOL KIT :- Supply and delivery at site best any Board approved make and other reputed make tool sets for operation and maintenance of the above pumpsets comprising of the following a) Double end spanner 1/4" to 1" 1 set,b) Screw driver insulated 11" - 1 No, c) Screw driver insulated 8" - 1 No, d) Cutting puller insulated 8" - 1 No,e) Hammer with handle 1 Kg - 1 No, f) Pipe wrench 24" 1 No, g) Pipe wrench 18" 1 No, h) Pipe wrench 12" - 1 No, i) Hammer with handle 5Kgs - 1 No, j) Grease gun - 1 No, k) Ring spanners 1/4" to 1" - 1 set, l) Supply of Testing Equipment (oil testing kit, Motorised megger of 5 kV, Manual megger of 1 kV, Digital multimeter, Tong tester) -etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

10000

... More
Transformer : Supply, erection, electrification and commissioning at site, brand new any other Board approved make oil immersed naturally cooled continuous duty with Copper winding 400 kVA 11 kV/433 volts 3 Ph 50 Hz Dyn 11 vector group distribution transformer conforming to IS1180 or its latest amendments fitted with the following and suitable for outdoor installation. The no load losses and full load losses shall be as per level 5 standards.(5 Star Rating)a) Dehydrating breather,b) Oil conservator, c) Drain plug for conservator, d) Off ciruit tap changer -5 TO +5 % in step of 2.5%, e) Thermometer pack with the thermometer,f) Base channel - 2 Nos,g) Lifting lugs 2 Nos,h) Flat rollers,i) Connecting pipes,j) Oil guage - 1 No.k) Filter valve,m) Air release plug - 1 No,n) Filter cum drain valve,o) Winding temperature indication with alarm and trip contacts,p)Oil temperature indication with alarm and trip contacts,q) Residual oil drain plug,r) Explosion vent,s) Detachable Radiators,t) Bushing for high voltage side,u) Cable box for low voltage side,v) Double float gas actuated Buccholz's relay with alarm and trip contacts,w) Earthing terminals,x)Marshalling Box,y) Oil filling hole with cap,The transformer shall be fitted with all other standard fittings and painted with high grey paint to shade No. 631 of ISS & shall be supplied with first filling of transformer oil etc., complete (test certificate shall be furnished) --etc with all lead and lift complete & as directed by engineer-in-charge.

1

-

129099

... More
Operation and maintenance of Bulk and Distribution water supply scheme including Head works, Raw Water, Pure water Pumping machinaries, Rising main, existing and proposed WTPs, feeder mains, OHTs, Distribution system, pumping stations etc for 1st year during defect liability period including cost of manpower, consumables, minor and major repairs etc complete.

1

-

7339672

... More
Operation and maintenance of Bulk and Distribution water supply scheme including Head works, Raw Water, Pure water Pumping machinaries, Rising main, existing and proposed WTPs, feeder mains, OHTs, Distribution system, pumping stations etc for 2nd year including cost of manpower, consumables, minor and major repairs etc complete.

1

-

8730189

... More
Operation and maintenance of Bulk and Distribution water supply scheme including Head works, Raw Water, Pure water Pumping machinaries, Rising main, existing and proposed WTPs, feeder mains, OHTs, Distribution system, pumping stations etc for 3rd year including cost of manpower, consumables, minor and major repairs etc complete.

1

-

9166699

... More
Operation and maintenance of Bulk and Distribution water supply scheme including Head works, Raw Water, Pure water Pumping machinaries, Rising main, existing and proposed WTPs, feeder mains, OHTs, Distribution system, pumping stations etc for 4th year including cost of manpower, consumables, minor and major repairs etc complete.

1

-

9625034

... More
Operation and maintenance of Bulk and Distribution water supply scheme including Head works, Raw Water, Pure water Pumping machinaries, Rising main, existing and proposed WTPs, feeder mains, OHTs, Distribution system, pumping stations etc for 5th year including cost of manpower, consumables, minor and major repairs etc complete.

1

-

10106285



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.