Karnataka State Road Transport Corporation Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Road Transport Corporation - KSRTC Tender

Works
Opening Date9 Mar 2025
Closing Date21 Mar 2025
Tender Amount₹ 4,55,56,746.59 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
004 - Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cmin depth, consolidating each deposited layer byramming and watering, lead up to 50 m and lift upto1.5 m.(SRP-2023-24/V-1/7/1.9)

581.14

266

154583.24

... More
005 - Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications(SRP 2023-24/V-1/11/1.23)

91.92

2682

246529.44

... More
006 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Form work all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarseaggregates (SRP-2023-24/V-1/2.1.4/15)

38.48

6217

239230.16

... More
007 - Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including Form Work & all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates For Footing (SRP-2023-24/V-1/2.4.3/16)

128.87

6526

841015.9296

... More
008 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form Work all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Column (SRP-2023-24/V-1/2.5.2/16)

37.96

11633

441592.476

... More
009 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form Work all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof Beam & Lintel(SRP-2023-24/V-1/2.5.2/16)

90.32

10948

988895.616

... More
010 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form Work all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof Slab(SRP-2023-24/V-1/2.5.2/16)

158.28

10264

1624665.06

... More
011 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form Work all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Chejja(SRP-2023-24/V-1/2.5.2/16)

5.7

9922

56557.395

... More
012 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including Form work all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Beam (SRP-2023-24/V-1/2.3.2/16)

42.01

9720

408337.2

... More
013 - Providing and fixing flush door shutter made out of solid core blockboard type, well seasoned , chemicaly treated hard wood battens andinternal frame with minimum 45 mm wide wooden frame alrounddoor shutters covered with cross bonded wooden sheets (core veneer)hot pressed and fastened on both sides of the door useing liquidphenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.(SRP-2023-24/V-2/12.57.1/105) -do- 30 mm thick Both side teak (Ground & First Floor)

72.53

4043

293238.79

... More
014 - Providing Mathi/Nandi wood frames of doors, windows, clerestorywindows, ventilators and other frames, wrought, framed or assembledincluding making plaster groves (excluding cost of cement concrete andside clamps ), but including cost of materials, labour, usage charges complete as per specifications.(SRP-2023-24/V-2/99/12.12)(Ground & First Floor)

5.49

124202

681868.98

... More
015 - Fixing of door frame in an existing opening including embedding framein floor and walls after cutting masonry for holdfasts for embeddingholdfast in cement concrete 1:3:6 of 20mm and down size granite metalpainting two coats of coal tar to sides of frame, making good the damagesto walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(SRP-2023-24/V-2/12.51/104)(Ground & First Floor)

33

1016

33528

... More
016 - Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam (SRP 23-24/page no 104/12.55.1) vol 2(Ground & First Floor)

31.5

2366

74529

... More
017 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(SRP-2023-24/V-2/11.34.A/86) (Ground & First Floor)

3432.24

168

576616.32

... More
018 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. (SRP-2023-24/V-2/14/6.8)

269.19

7969

2145175.11

... More
019 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge Inside(SRP-2023-24/V-2/8.5.2/42) (Ground & First Floor)

3089.62

349

1078277.38

... More
020 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Out Side(SRP-2023-24/V-2/8.4.2/41)(Ground & First Floor)

2234.47

312

697154.64

... More
021 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Ceiling (SRP-2023-24/V-2/8.6.1/42) (Ground & First Floor)

1572.88

323

508040.24

... More
022 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(SRP-2023-24/V-2/12.87/109) (Ground & First Floor)

149.4

6551

978719.4

... More
023 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).(SRP-2023-24/V-2/12.85/109)(Ground & First Floor)

6.48

5719

37059.12

... More
024 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(SRP-2023-24/V-2/85/11.28)(Ground & First Floor)

1621.26

565

916011.9

... More
025 - Providing lime wash on walls with one coat with lime of approved quality to give an even shade, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(SR 2023-24/P no 44/8.22) vol 2(Ground & First Floor)

4015

10

40150

... More
026 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black,Cherry Red, Brown, Cat Eye, River Pink or equivalent.(SRP-2023-24/V-2/9.24/63)(Ground & First Floor)

1216.64

2852

3469857.28

... More
027 - Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete-Size of Tile 600x600 mm(SR 2023-24/p-61/9.17.2)vol-2(Ground & First Floor)

358.02

1175

420673.5

... More
028 - Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.(SR 2023-24/p-71/10.18)vol-2(Ground & First Floor)

140.26

3359

471133.34

... More
029 - Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.(SR 2023-24/P no 69/10.2)vol 2(Ground & First Floor)

149.92

328

49173.76

... More
030 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. buildings (SRP-2023-24/V-1/2.11 a/18) (Ground & First Floor)

63.91

89457

5717196.87

... More
031 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge(Ground & First Floor)

14708.8

113

1662094.4

... More
032 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(SR 23-24/P no 26/7.38)vol 2(Ground & First Floor)

122.04

568

69318.72

... More
033 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)(SR 2023-24/P no 26/7.39.1)vol 2 (Ground & First Floor)

14

451

6314

... More
034 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories,sealing shall be done with necessary rods etc., complete For Straight Portion (SR 2023-24/page no 71/10.15.1) vol 2(Ground & First Floor)

227.05

3989

905702.45

... More
035 - Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. (SR 2023-24 /vol 2/P 181,182/18.2)

55.52

2685

149071.2

... More
036 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(SR 2023-24/P no 191/16.9)vol 5

13

5454

70902

... More
037 - Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.(SR 2023-24/Vol 2/P no 176/17.12)

13

928

12064

... More
038 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for:PVC pipes 110mm dia., 6kg/sqcm& class 3 (SR 2023-24 P 113/10.1.7 vol 5)(Ground & First Floor)

450

411

184950

... More
039 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for:PVC pipes 160mm dia., 6kg/sqcm& class 3 (SR 2023-24 P 113/10.1.9 vol 5)(Ground & First Floor)

425

618

262650

... More
040 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (SRP-2023-24/V-2/8.40/48)(Ground & First Floor)

1120

115

128800

... More
041 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (SR 2023-24/Vol 2/page no 46/8.30)(Ground & First Floor)

5250

174

913500

... More
042 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(SR 2023-24/Vol 2/P no 50/8.51)(Ground & First Floor)

4787.68

100

478768

... More
043 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(SR 2023-24/Vol 2/p no 48/8.39)(Ground & First Floor)

2950

127

374650

... More
044 - Providing and placing on terrace(at all floor levels) polyethylene water storage tanks IS:12701 marked, with cover and suitable locking arrangements & making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank. (SR 2023-24/Vol 2 / Page no 123/13.34)(Ground & First Floor)

12000

9

108000

... More
045 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step CPVCsolvent cement, trenching, refilling & testing of joints complete as per the direction of the Engineer-in-charge. (External work) - 32mm nominal OD pipes(SR 2023-24/Vol 2/Page no122,123/13.33.3,4,5)(Ground & First Floor)

436

372

162192

... More
046 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step CPVCsolvent cement, trenching, refilling & testing of joints complete as per the direction of the Engineer-in-charge. (External work) - 25mm nominal OD pipes(SR 2023-24/Vol 2/Page no122,123/13.33.3,4,5)(Ground & First Floor)

320

296

94720

... More
047 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step CPVCsolvent cement, trenching, refilling & testing of joints complete as per the direction of the Engineer-in-charge. (External work) - 40mm nominal OD pipes(SR 2023-24/Vol 2/Page no122,123/13.33.3,4,5)

200

477

95400

... More
048 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, includes fixing the pipe with clamps 1.00 m spacing .this includes jointing of pipes and fittings with one step CPVC solvent cement & testing of joints complete. (Concealed work)-exposed on wall. - 20mm nominal OD pipes(SR 2023-24/Vol 2/page no 122/13.32.2)

50

379

18950

... More
049 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers (SR 2023-24/vol 2/P no.133/14.7.8)(Ground & First Floor)

16

3444

55104

... More
050 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid(SR 2023-24/vol 2/p-131/14.3.1)(Ground & First Floor)

16

5977

95632

... More
051 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(SR 2023-24/vol 2/p-131/14.1.1)(Ground & First Floor)

12

4884

58608

... More
052 - Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm (SR 2023-24/Vol 2/P no136/14.32.2) (Ground & First Floor)

16

1018

16288

... More
053 - Providing and fixing 100 mm sand cast Iron grating for gully trap. (SRP-2023-24/V-2/14.29/136)(Ground & First Floor)

40

47

1880

... More
054 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) (SRP-2023-24/V-2/13.4.3/117) 40 mm nominal bore

8

702

5616

... More
055 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) (SRP-2023-24/V-2/13.4.2/117) 32 mm nominal bore(Ground & First Floor)

8

598

4784

... More
056 - Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 165 mm long, weighing not less than 110 g(SRP-2023-24/V-2/13.17.3/120)(Ground & First Floor)

44

223

9812

... More
057 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (SR 2023-24/vol 2/p-60/9.11)(Ground & First Floor)

131.76

889

117134.64

... More
058 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications(SR 2023-24/vol 2/p-65/9.39)(Ground & First Floor)

407.32

1449

590206.68

... More
059 - Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. (SR 2023-24/vol 2/P 65/9.40)

256.4

932

238964.8

... More
060 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth (SR 2023-24/vol 1/page no 8/1.12)

343.75

95

32656.25

... More
061 - Hydraulic Excavator of 1.2 m3 bucket (SR 2023-24/vol 1/A 44/51)

39

1800

70200

... More
062 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore (SR 2023-24/vol 2/P 117/13.4.1)

12

549

6588

... More
063 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (SR 2023-24/vol 2/P 9/5.4)

78.94

6389

504347.66

... More
064 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including Form Work of all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates Sump Raft(SRP-2023-24/V-1/2.4.3/16)

10.6

6526

69176.448

... More
065 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including Form Work of all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates Sump Slab(SRP-2023-24/V-1/2.4.3/16)

22.32

9504

212129.28

... More
066 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. buildings all other types of structure for Sump (SRP-2023-24/V-1/2.11 a/18)

3.16

79011

249674.76

... More
067 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(SRP-2023-24/V-2/15.1/149)

580.26

817

474072.42

... More
068 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) (SR 2023-24/Vol 5/p no 139/12.1.1 to 9) 0.00 to 50.00Rmt

50

370

18500

... More
069 - Do 50.00 to 100.00Rmt

50

464

23200

... More
070 - Do 100.00 to 150.00Rmt

50

493

24650

... More
071 - Do 150.00 to 200.00Rmt

50

572

28600

... More
072 - Do 200.00 to 250.00Rmt

50

671

33550

... More
073 - Do 250.00 to 300.00Rmt

50

740

37000

... More
074 - Do 300.00 to 350.00Rmt

50

868

43400

... More
075 - Do 350.00 to 400.00Rmt

50

937

46850

... More
076 - Do 400.00 to 450.00Rmt

100

1184

118400

... More
077 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.(SR 23-24/vol 5/P no 143/12.32)

150

1933

289950

... More
078 - Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments (SR 23-24/vol 5/P no 143/12.33)

10

150

1500

... More
079 - Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge (SR 23-24/vol 5/P no 143/12.34)

1

164

164

... More
080 - Geophysical investigation at site for sinking borewells for supplyingdrinking water to the habitation either through the Hand Pump MWS orP.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergers’s method, including reconnaissance survey of geologicalformation. Geophysical investigation of existing ground water in thevicinity, its quality, quantity and acceptability of the users, indicatingthe location of the site, recommended depth of casing pipe required toseal the top unconsolidated formation including an extra depth of 1.0metre in consolidated formation for proper seating of casing pipe, depthof drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportationof instruments and accessories to work site, engaging technical personaland labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M(for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%,b) Above 30 M - 30% (Measurement of overburden is restricted to thedepth of casing pipe fixed excluding initial depth of 20M and projectionabove ground level). 2) A sum of Rs. 100/- is to be deducted for DryBorewell towards yield test.5 (SR 2023-24/vol 5/P no.140/12.4)

2

5288

10576

... More
081 - Providing and fixing PTMT stop cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 (SRP-2023-24/V-2/13.18.1/120)

50

131

6550

... More
082 - Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern(SR 2023-24/vol 2/p-132/14.5.1)

8

8642

69136

... More
083 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step CPVCsolvent cement, trenching, refilling & testing of joints complete as per the direction of the Engineer-in-charge. (External work) - 25mm nominal OD pipes(SR 2023-24/Vol 2/Page no122,123/13.33.3,4,5)

50

217

10850

... More
084 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.(SR 2023-24/vol 2/p-70/10.8)

6.75

2789

18825.75

... More
085 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form Work all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Toilet Lintel & Beam(SRP-2023-24/V-1/2.5.2/16)

2.92

10137

29601.792

... More
086 - Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary /Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery & other appurtenances required to complete the work. on ordinary/soft rock upto 300mm depth(SR 2023-24/vol-1, I no-1.13)

187.5

362

67875

... More
087 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width ) trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata -Depth exceeding 1.5 m, but not exceeding 3 m(SR 23-24/vol-1/p.no-10/I no 1.17.2)

204.98

331

67848.38

... More
088 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, Form work quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (SR 2023-24/vol-1/p.no-15/I no 2.2.3)

58.79

6842

402292.9152

... More
089 - Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

72.5

6205

449862.5

... More
090 - Providing Flush/ Ruled pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.(SR 2023-24/Vol 2/p no 44/I no-8.20)

49.08

142

6969.36

... More
091 - Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work(SR 2023-24 / vol 2/p no-13/I no 6.4)

75.77

8661

656243.97

... More
092 - Providing Tile brick masonry work 5 cm thick with common burnt clay Non Modular tile bricks of class designation 5.0 conforming to IS 2690 (Part I) in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth and upto floor I level including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(SR 2023-24/vol 2/p no 15/I no 6.21)

13.39

987

13215.93

... More
093 - Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(p-44/8.21)vol-2/23-24

687.68

26

17879.68

... More
094 - Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm(p-62/9.22.2)vol-2/23-24

213.9

1326

283631.4

... More
095 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications..(p-64/9.30)vol-2/23-24

19.95

5328

106293.6

... More
096 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) (p-46/8.33.1)vol-2/23-24

696.99

158

110124.42

... More
097 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(p-48/8.41)vol-2/23-24

150

167

25050

... More
098 - Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures )(SR 2023-24/vol2 /p-100/I no 12.18)

49.35

6576

324525.6

... More
099 - Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(p-77/11.3)vol-2/23-24

8.4

8276

69518.4

... More
100 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE Grade PE80-PN6.0 110mm dia

40

469

18760

... More
101 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE Grade PE80-PN6.0, 63mm dia

50

189

9450

... More
102 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification:-do- 30 mm thick both side commercial(p-105/12.57.3)vol-23-24

27.5

3005

82637.5

... More
103 - Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications(SR 23-24/vol 2/P no 104/I no 12.52)

14

773

10822

... More
104 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall:20 mm nominal dia Pipes(p-122/13.31.2)vol-2/23-24

150

242

36300

... More
105 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall:75 mm nominal dia Pipes(p-122/13.31.3)vol-2/23-24

150

318

47700

... More
106 - Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete(p-127/13.59)vol-2/23-24

10

220

2200

... More
107 - Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern(p-132/14.5.4)vol-2/23-24

5

18968

94840

... More
108 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps(p-132/14.7.3)vol-2/23-24

5

2345

11725

... More
109 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(p-136/14.31)vol-2/23-24

2

1220

2440

... More
110 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form Work all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Column(First Floor) (SRP-2023-24/V-1/2.5.2/16)

21.96

11749

258017.4828

... More
111 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form Work all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof Beam & Lintel (First Floor)(SRP-2023-24/V-1/2.5.2/16)

33.58

11058

371337.3782

... More
112 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form Work all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof Slab (First Floor)(SRP-2023-24/V-1/2.5.2/16)

65.15

10367

675419.8225

... More
113 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form Work all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Chejja (First Floor)(SRP-2023-24/V-1/2.5.2/16)

3

10021

30064.71

... More
114 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work..(First Floor) (SRP-2023-24/V-2/14/6.8)

209.67

8048

1687568.8323

... More
115 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. buildings (SRP-2023-24/V-1/2.11 a/18) (First Floor)

15

90351

1355273.55

... More
116 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201 1.5 sqmm(BESCOM Part-I/P-3/2.3.2)

2000

26

52000

... More
117 - Do-2.5 sqmm(BESCOM Part-I/P-3/2.3.3)

1500

42

63000

... More
118 - Do- 4 sqmm (BESCOM Part-I/P-3/2.3.4)

1000

63

63000

... More
119 - Do- 6 sqmm(BESCOM Part-I/P-3/2.3.5)

150

92

13800

... More
120 - Do- 10 sqmm(BESCOM Part-I/P-3/2.3.6)

100

167

16700

... More
121 - Do- 16 sqmm(BESCOM Part-I/P-3/2.3.7)

50

318

15900

... More
122 - Concealed Conduit System : Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick (BESCOM Part-I/P-1/1.2.1)

1000

66

66000

... More
123 - 25mm dia 2mm thick(BESCOM Part-I/P-1/1.3.2)

1000

78

78000

... More
124 - Open Conduit System :Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick (BESCOM Part-I/P-1/1.1.2)

500

81

40500

... More
125 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point above 3Mtr upto 6Mtr from tapping point to out let via switch box (BESCOM Part-I/P-3/2.2.1)

150

269

40350

... More
126 - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box (BESCOM Part-I/P-3/2.2.2)

200

379

75800

... More
127 - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box (BESCOM Part-I/P-3/2.2.3)

250

555

138750

... More
128 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2Way(BESCOM Part-I/P-5/3.3.1)

5

103

515

... More
129 - do. 3-5Way(BESCOM Part-I/P-5/3.3.2)

5

124

620

... More
130 - do. 6Way(BESCOM Part-I/P-5/3.3.3)

5

173

865

... More
131 - do. 10-12Way(BESCOM Part-I/P-5/3.3.5)

50

261

13050

... More
132 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way (BESCOM Part-I/P-5/3.4.1)

5

138

690

... More
133 - do. 3 Way(BESCOM Part-I/P-5/3.4.2)

5

159

795

... More
134 - do. 6Way(BESCOM Part-I/P-5/3.4.3)

5

220

1100

... More
135 - do. 8Way(BESCOM Part-I/P-5/3.4.4)

5

261

1305

... More
136 - do. 10-12Way (BESCOM Part-I/P-5/3.4.5)

50

319

15950

... More
137 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2Module (BESCOM Part-I/P-5/3.5.1)

10

137

1370

... More
138 - do. 3 Module (BESCOM Part-I/P-5/3.5.2)

10

161

1610

... More
139 - Do- 8 Module(BESCOM Part-I/P-5/3.5.4)

10

284

2840

... More
140 - Do- 10-12 Module (BESCOM Part-I/P-5/3.5.5)

100

344

34400

... More
141 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch(BESCOM Part-I/P-5/3.6.1 6)

500

102

51000

... More
142 - Do- 6Amps 3way socket (BESCOM Part-I/P-5/3.6.3)

300

171

51300

... More
143 - Do- Stepped Fan Regulator. (BESCOM Part-I/P-5/3.6.4)

30

357

10710

... More
144 - Do-16Amps one way switch (BESCOM Part-I/P-5/3.6.8)

20

180

3600

... More
145 - Do- 6Amps Bell push(BESCOM Part-I/P-5/3.6.9)

5

177

885

... More
146 - Do- 32Amps DP switch (BESCOM Part-I/P-5/3.6.10)

30

326

9780

... More
147 - Do- 6/16Amps universal socket (BESCOM Part-I/P-5/3.6.11)

15

236

3540

... More
148 - Do- TV/Telephone socket (BESCOM Part-I/P-5/3.6.12)

1

156

156

... More
149 - Do-RJ45/I.O.outlet Cat-6 (BESCOM Part-I/P-5/3.6.13)

100

337

33700

... More
150 - Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm(BESCOM Part-I/P-2/1.9.2)

50

22

1100

... More
151 - Do- 32mm(BESCOM Part-I/P-2/1.9.3)

20

29

580

... More
152 - Supplying and drawing UTP-CAT 6E LAN cable.(BESCOM Part-I/P-27/8.1)

2000

38

76000

... More
153 - Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc , and fixing on existing wooden or metal box using N.F. screws.(BESCOM Part-I/P-6/3.8)

5000

-

2050

... More
154 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4'- 20/22 w (BESCOM Part-I/P-34/11.3.2)

80

690

55200

... More
155 - LED Street light : .Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 70 Watts(BESCOM Part-I/P-36/11.8.3)

5

5992

29960

... More
156 - Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' /1' X 4' 34 -36watt (BESCOM Part-I/P-35/11.6.2 )

4

5898

23592

... More
157 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ LumenMaintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment& impact resistance of complete luminaire IK08. Power Factor 0.9 withmains, Surge Protection- Min 5KV along with Over voltage/ Overload,short circuit/ miss-wiring protection. Compatible for pole mauling with outerdia of 40mm to 50mm. Universal Voltage driver to operate wide voltage rangefrom 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598,M 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top accessstreet light with single screw to ensure ease of maintenance at the sight sitelocation with minimized minimal tools. LED Light fixture with ....... W SystemPower consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminairemanufacturer should have in- house facility accredited by NABL / CPRI & anyGovernment certified agency & Design & Development facility certified byISO 9001:2008. Housing with supplier word mark / name shall be Engraved /Embossing on the die cast housing / Body part Warranty of 2 Years against anymanufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 200W

2

18581

37162

... More
158 - Do-LED Floodlight 240WBESCOM Part-I/P-36/111.9.7)

2

22068

44136

... More
159 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)

25

2677

66925

... More
160 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable for operate on 230V 50Hz, AC supply complete. (15" sweep (450mm) Make: Crompton / Almonard (BESCOM Part-I/P-22/6.2.2)

2

4446

8892

... More
161 - Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.(BESCOM Part-I/P-22/6.1)

1

1492

1492

... More
162 - Fixing all types and all capacities fluorescent / CFL / false ceiling fixtures indoor on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (if required) On wall/ ceiling/ rafter/girders (BESCOM Part-I/P-45/13.7.1)

97

122

11834

... More
163 - Supplying and fixing 32mm dia class A GI pipe bracket upto 2.7 meters long for fixing MV/SV/MH/FTL street light fitting of all capacities on wall using suitable clamps, bolts and nuts and wiring using suitable capacity wires etc complete. Using 40mm dia GI pipe. (BESCOM Part-I/P-45/13.2.2)

5

1295

6475

... More
164 - Fixing a ceiling / wall mounting fan of all capacities and all types to the existing S hook together with supplying and fixing a 5 ampers ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring completely. (BESCOM Part-I/P-46/13.11)

30

315

9450

... More
165 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5Amps ceiling rose with sufficient length of 23/0.0076inch PVC insulated twin core wire of approved make. (BESCOM Part-I/P-46/13.14)

3

492

1476

... More
166 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP (BESCOM Part-I/P-13/5.17.1)

4

415

1660

... More
167 - 6-32Amps DP (BESCOM Part-I/P-13/5.17.4)

5

739

3695

... More
168 - 40Amps DP(BESCOM Part-I/P-13/5.17.5)

5

1060

5300

... More
169 - 6-32Amps TPN(BESCOM Part-I/P-13/5.17.7)

10

1717

17170

... More
170 - 40 Amps TPN((BESCOM Part-I/P-13/5.17.8)

5

3044

15220

... More
171 - Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 1- Single Door II -Double Door Ill -Double Door 4Way SP &N (BESCOM Part-I/P-13/5.18.6)

5

1524

7620

... More
172 - Do- 8Way SP &N(BESCOM Part-I/P-13/5.18.8)

2

1854

3708

... More
173 - Do- 12Way SP &N(BESCOM Part-I/P-13/5.18.9)

3

2329

6987

... More
174 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. 100Amps 25kA.(BESCOM Part-I/P-13/5.14.1)

2

6086

12172

... More
175 - Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. (BESCOM Part-I/P-14/5.34)

6

562

3372

... More
176 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (BESCOM Part-I/P-14/5.38)

6

515

3090

... More
177 - Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor.(BESCOM Part-I/P-14/5.37)

15

480

7200

... More
178 - Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs (BESCOM Part-I/P-15/5.39)

1

21640

21640

... More
179 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy (BESCOM Part-I/P-14/5.33)

2

9315

18630

... More
180 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG (BESCOM Part-I/P-15/5.42.2)

100000

-

43000

... More
181 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips (BESCOM Part-I/P-15/5.40.1)

3

2465

7395

... More
182 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm (BESCOM Part-I/P-15/5.41.1)

10

305

3050

... More
183 - Do-50x50x6mm (BESCOM Part-I/P-14/5.41.2)

10

395

3950

... More
184 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia

5

3510

17550

... More
185 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia

8

4256

34048

... More
186 - SGI/Copper strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI strip

80

82

6560

... More
187 - Do- 600 x 600 x 3 mm Copper plate

8

7421

59368

... More
188 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmm(BESCOM Part-III/P-9/32.05)

0.2

141842

28368.4

... More
189 - Do- 3.5 core 25 sqmm(BESCOM Part-III/P-9/32.07)

0.3

139549

41864.7

... More
190 - Do- 3.5 core 50 sqmm (BESCOM Part-III/P-9/32.11)

0.1

178973

17897.3

... More
191 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm(BESCOM Part-IV/P-9/ 31.05)

0.2

20886

4177.2

... More
192 - Do- 35 to 95 Sqmm(BESCOM Part-IV/P-9/ 31.06)

0.4

31139

12455.6

... More
193 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C X 4.0Sq.mm(BESCOM Part-I/P-4/2.6.3)

200

168

33600

... More
194 - Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl& Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work.7.50 HP - 90 LPM @ 165 m = 15 STG Outlet Dia - 2.00”(PWD PArt-V/P-160/15.7)

1

40810

40810

... More
195 - Do-3.00 HP - 300 LPM @ 26 m = 2 STG Outlet Dia - 2.50”(PWD PArt-V/P-159/11.1)

1

23168

23168

... More
196 - Supplying.....litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25 Litres (BESCOM Part-I/P-15/7.1.3)

1

10242

10242

... More
197 - Erection charges for fixing a …liters capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top. Up to 30 Litres (BESCOM Part-I/P-15/13.15.1)

1

664

664

... More
198 - Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode 200 L- 20 nos Tubes

1

43222

43222

... More
199 - Distribution Transformer - 3 Phase,11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 B. CABLE ENTRY TYPE 63 kVA, Aluminum Wdg, Star 2 (5 Star) (BESCOM Part-III/P-4/12.14)

1

186170

186170

... More
200 - Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977For 25/63/100 kVA 4/5 Star Rated Transformer on PSCC Pole - 9 Mtr Long, 300 Kg WL - MS (Dwg No. BESCOM/GM/QS&S/62 Dtd 24.11.2018) (BESCOM Part-III/P-4/12.16)

2

17564

35128

... More
201 - RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 (BESCOM Part-III/P-1/1.01)

2

7076

14152

... More
202 - PSCC Pole - 11 Mtr Long, 365 Kg WL for Intermediate Poles only as per REC Standards (BESCOM Part-III/P-1/ 1.09)

11

7913

87043

... More
203 - 11 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018) (BESCOM Part-III/P-1/2.01)

10

372

3720

... More
204 - 11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod) (BESCOM Part-III/P-2/6.05)

30

205

6150

... More
205 - 11 kV, 45 kN Polymeric Insulator (BESCOM Part-III/P-3/6.12)

6

186

1116

... More
206 - 11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) (BESCOM Part-III/P-8/ 24.01)

2

9450

18900

... More
207 - Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM (BESCOM Part-III/P-3/7.02)

3

46234

138702

... More
208 - Stringing of conductor Rabbit ACSR binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. (BESCOM Part-IV/P-3/ 5.17 )

3

4361

13083

... More
209 - 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)(BESCOM Part-III/P-10/36.01)

0.05

889666

44483.3

... More
210 - Load Break Switch with Panel (BESCOM Part-III/P-13/ 41.01 )

1

73239

73239

... More
211 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff HT Cable 3x95 to 150 Sqmm(BESCOM Part-IV/P-9/ 31.01 )

0.05

61322

3066.1

... More
212 - Erection of 25 to 63 kVA Transformer on Transformer Structure(BESCOM Part-IV/P-3/ 7.01 )

1

863

863

... More
213 - Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment. Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour. Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr with cement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.(BESCOM Part-IV/P2/ 4.06 )

3

30361

91083

... More
214 - Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved DrawingHard Soil (BESCOM Part-IV/P1/ 1.1.2 )

4

1132

4528

... More
215 - Digging of Pit 2.2 Mtr depth for erection of 11 Mtr Long RCC/PSCC supports as per approved DrawingHard Soil(BESCOM Part-IV/P1/1.4.2)

9

1384

12456

... More
216 - Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth(BESCOM Part-IV/P2/ 2.02 )

4

1113

4452

... More
217 - Erection of PSCC Pole 11 Mtr Long 365 Kg WL in a pit of 2.2 Mtr depth(BESCOM Part-IV/P2/ 2.04 )

9

1828

16452

... More
218 - 9 kV 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No. BESCOM/GM/QS&S/26 03 Nos Set

1

920

920

... More
219 - 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification(BESCOM Part-III/P8/ 25.01 )03 Nos Set

1

5875

5875

... More
220 - LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018)(BESCOM Part-III/P6/ 18.01 )

1

22686

22686

... More
221 - Heat Shrinkable Outdoor Type Cable Termination Kit for PILC Cable 3x95 Sqmm (BESCOM Part-III/P15/ 45.13 )

2

3976

7952

... More
222 - Heat Shrinkable Indoor Type Cable Termination Kit for PILC Cable 3x95 Sqmm(BESCOM Part-III/P15/ 45.10 )

6

3138

18828

... More
223 - Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. (BESCOM Part-IV/P12/38 )

55

987

54285

... More
224 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . 18U with 650mm depth(BESCOM Part-I/P28/8.4.5 )

1

28396

28396

... More
225 - Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel(BESCOM Part-I/P28/8.12.5 )

2

7900

15800

... More
226 - Supplying & Fixing of …mtrs Cat6 Patch Cable. 1mtr (BESCOM Part-I/P28/8.11.1 )

110

224

24640

... More
227 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e NOTE: 1) DOL- Direct Online Starter Upto 6 HP pumps

1

9550

9550

... More
228 - D0- 6 to 15 HP pumps

1

15900

15900

... More
229 - Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.(BESCOM Part-I/P14/5.31)

3

4390

13170

... More
230 - Labour charges for Erection, Electrification and ommissioning of Pumpsets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (PWD PArt-V/P-163/38)

1

6500

6500

... More
231 - Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. 62.5 KVA

1

77768

77768

... More
232 - Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Tn Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self r Control Panel: The control panel is manufactured with 14/16 gauge Running Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protection Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically the control system from sleep mode. Engine Starting -The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sees to start after remote start signal and time delay of 0- 600secs prior to shut down after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective functions include, Configurable alarm output, Emergency stop: Annunciated whenever an emergency stop signal is received by the control. Low lube oil pressure warning and Shutdown, High engine water temp warning / Shutdown, Low coolant temp warning, Sensor failure indication, Low and high battery voltage warning, Weak battery warning, Fail to start shut down, Cracking lockout: Control will not allow the starter to engage or to crank the running engine Cyclic cranking: Configurable for the number of starting cycle, (1 to 7) and duration of crank and rest periods. Alternator Protective functions includes, - High and Low AC voltage shut down, Under and Over frequency shutdown / warning, Loss of sensing voltage input shut down. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 m sound levels specified by Ministry of louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment, Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. 62.5KVA/50kw (BESCOM Part-I/P32/10.1.3)

1

641071

641071

... More
233 - Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS (BESCOM Part-I/P29/9.3.3)

2

68383

136766

... More
234 - Do 10KVA On Line UPS

1

103570

103570

... More
235 - Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries 60 /65 AH capacity.(BESCOM Part-I/P29/9.5.5)

40

6413

256520

... More
236 - Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.5 star 1.5 Ton capacity(BESCOM PART-I/6.8.5/P24)

1

56355

56355

... More
237 - Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.(BESCOM PART-I/6.22/P25)

1

4807

4807

... More
238 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable A ngle Iron support upto 3.0 Ton split/cassette type A/C.(BESCOM PART-I/6.12/P24)

1

3175

3175

... More
239 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box (BESCOM part-III/P-5/2.2.1)

20

269

5380

... More
240 - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box (BESCOM Part-III/P-5/2.2.2)

20

379

7580

... More
241 - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box (BESCOM Part-III/P-5/2.2.3)

25

570

14250

... More
242 - Concealed Conduit System : Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick (BESCOM Part-III/P-2/1.2.1)

200

66

13200

... More
243 - 25mm dia 2mm thick(BESCOM Part-III/P-2/1.2.2)

200

78

15600

... More
244 - Open Conduit System :Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick (BESCOM Part-III/P-2/1.1.2)

500

81

40500

... More
245 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2Way(BESCOM Part-III/P-8/3.3.1)

10

103

1030

... More
246 - do. 10-12Way(BESCOM Part-III/P-8/3.3.6)

10

261

2610

... More
247 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way (BESCOM Part-III/P-8/3.4.1)

50

138

6900

... More
248 - do. 10-12Way (BESCOM Part-III/P-8/3.4.6)

10

319

3190

... More
249 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module (BESCOM Part-III/P-8/3.5.1)

20

137

2740

... More
250 - Do- 10-12 Module (BESCOM Part-III/P-8/3.5.6)

20

344

6880

... More
251 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch(BESCOM Part-III/P-9/3.6.1 )

10

102

1020

... More
252 - Do- 6Amps 3way socket (BESCOM Part-III/P-9/3.6.3)

10

171

1710

... More
253 - Do- Stepped Fan Regulator. (BESCOM Part-III/P-9/3.6.4)

1

357

357

... More
254 - Do- TV/Telephone socket (BESCOM Part-III/P-9/3.6.11)

1

156

156

... More
255 - Do-RJ45/I.O.outlet Cat-6 (BESCOM Part-III/P-9/3.6.12)

100

337

33700

... More
256 - Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm(BESCOM Part-III/P-3/1.9.2)

50

22

1100

... More
257 - Do- 32mm(BESCOM Part-III/P-3/1.9.3)

20

29

580

... More
258 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 1.5 sqmm(BESCOM Part-III/P-5/2.3.2)

300

26

7800

... More
259 - Do-2.5 sqmm(BESCOM Part-III/P-5/2.3.3)

800

42

33600

... More
260 - Do- 4 sqmm (BESCOM Part-III/P-5/2.3.4)

1000

63

63000

... More
261 - Supplying and drawing UTP-CAT 6E LAN cable.(BESCOM Part-III/P-36/8.6)

2500

38

95000

... More
262 - Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc , and fixing on existing wooden or metal box using N.F. screws.(BESCOM Part-III/P-9/3.8)

6000

-

2460

... More
263 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4'- 20/22 w (BESCOM Part-III/P-43/11.3.2)

20

690

13800

... More
264 - LED Street light : .Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 70 Watts(BESCOM Part-III/P-46/11.8.3)

2

5992

11984

... More
265 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) (BESCOM Part-III/P-30/6.4.1)

10

2677

26770

... More
266 - Fixing all types and all capacities fluorescent / CFL / false ceiling fixtures indoor on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (if required) On wall/ ceiling/ rafter/girders (BESCOM Part-III/P-56/13.7.1)

20

122

2440

... More
267 - Supplying and fixing 32mm dia class A GI pipe bracket upto 2.7 meters long for fixing MV/SV/MH/FTL street light fitting of all capacities on wall using suitable clamps, bolts and nuts and wiring using suitable capacity wires etc complete. Using 40mm dia GI pipe. (BESCOM Part-III/P-56/13.2.2)

2

1295

2590

... More
268 - Fixing a ceiling / wall mounting fan of all capacities and all types to the existing S hook together with supplying and fixing a 5 ampers ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring completely. (BESCOM Part-III/P-57/13.11)

10

315

3150

... More
269 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP (BESCOM Part-III/P-17/5.18.1)

6

415

2490

... More
270 - 6-32Amps DP (BESCOM Part-III/P-17/5.18.4)

5

739

3695

... More
271 - 40Amps DP(BESCOM Part-III/P-17/5.18.5)

5

1060

5300

... More
272 - 6-32Amps TPN(BESCOM Part-III/P-17/5.18.7)

5

1717

8585

... More
273 - 40 Amps TPN((BESCOM Part-III/P-17/5.18.8)

2

3044

6088

... More
274 - Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 1- Single Door II -Double Door Ill -Double Door 4Way SP &N (BESCOM Part-III/P-18/5.19.6)

1

1524

1524

... More
275 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. 100Amps 25kA.(BESCOM Part-III/P-17/5.15.1)

1

6086

6086

... More
276 - Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. (BESCOM Part-III/P-19/5.34)

3

562

1686

... More
277 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (BESCOM Part-III/P-19/5.38)

3

515

1545

... More
278 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy (BESCOM Part-III/P-19/5.33)

1

9315

9315

... More
279 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG (BESCOM Part-III/P-20/5.42.2)

41000

-

17630

... More
280 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips (BESCOM Part-III/P-20/5.40.1)

1

2465

2465

... More
281 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm (BESCOM Part-III/P-20/5.41.1)

5

305

1525

... More
282 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia(BESCOM Part-III/P-54/12.56)

5

3510

17550

... More
283 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip (BESCOM Part-III/P-54/12.58.2)

20

82

1640

... More
284 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmm(BESCOM Part-II/P-13/32.05)

0.51

141842

72339.42

... More
285 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm(BESCOM/P-52/ 21.05)

0.51

20886

10651.86



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.