Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 1,79,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
PHC/CNT/BGM/TND/134/2021-22/WI-1689Bid Award Id
ViewTender No
PHC/CNT/BGM/TND/134/2021-22/WI-1689Tender Authority
Karnataka State Police Housing And Infrastructure Development Corporation Limited ViewPurchaser Address
-Website
http://eproc.karnataka.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 19/20mm dia 2mm thick ---- as per directions of Engineer in-charge of work.
160
-
8160
... More
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick ---- as per directions of Engineer in-charge of work.
120
-
6480
... More
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 1- Single Door II -Double Door Ill -Double Door - 4Way TP &N ---- as per directions of Engineer in-charge of work.
2
-
5300
... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 1-3Way ---- as per directions of Engineer in-charge of work.
22
-
2090
... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 4-5Way ---- as per directions of Engineer in-charge of work.
6
-
630
... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6Way ---- as per directions of Engineer in-charge of work.
4
-
500
... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8Way ---- as per directions of Engineer in-charge of work.
18
-
2610
... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12Way ---- as per directions of Engineer in-charge of work.
6
-
990
... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 16-18Way ---- as per directions of Engineer in-charge of work.
4
-
720
... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short point upto 3Mtr from tapping point to out let via switch box ---- as per directions of Engineer in-charge of work.
28
-
4480
... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- as per directions of Engineer in-charge of work.
38
-
9500
... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- as per directions of Engineer in-charge of work.
8
-
3000
... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 1.5 sqmm ---- as per directions of Engineer in-charge of work.
720
-
14760
... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 2.5 sqmm ---- as per directions of Engineer in-charge of work.
1360
-
43520
... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 4 sqmm ---- as per directions of Engineer in-charge of work.
270
-
12150
... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 6 sqmm ---- as per directions of Engineer in-charge of work.
90
-
6300
... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 1 to 3 Module ---- as per directions of Engineer in-charge of work.
22
-
2420
... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 Module ---- as per directions of Engineer in-charge of work.
6
-
750
... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 6 Module ---- as per directions of Engineer in-charge of work.
4
-
700
... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8 Module ---- as per directions of Engineer in-charge of work.
18
-
3600
... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 10-12 Module ---- as per directions of Engineer in-charge of work.
6
-
1380
... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 16-18 Module ---- as per directions of Engineer in-charge of work.
4
-
1080
... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps one way Switch ---- as per directions of Engineer in-charge of work.
148
-
10360
... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps Two way Switch ---- as per directions of Engineer in-charge of work.
4
-
380
... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps 3way socket ---- as per directions of Engineer in-charge of work.
36
-
3780
... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - Stepped Fan Regulator. ---- as per directions of Engineer in-charge of work.
14
-
4060
... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 32Amps DP switch ---- as per directions of Engineer in-charge of work.
4
-
728
... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6/16Amps universal socket ---- as per directions of Engineer in-charge of work.
4
-
648
... More
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- as per directions of Engineer in-charge of work.
52
-
5512
... More
Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- as per directions of Engineer in-charge of work.
4
-
4800
... More
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 °C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. - 48" Sweep 5 Star (1200mm) ---- as per directions of Engineer in-charge of work.
14
-
40600
... More
Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - 18W-20W (T8) Polycarbonate/OPAL Acrylic Casing ---- as per directions of Engineer in-charge of work.
28
-
11900
... More
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED modular down light 1 'x1' 34 -22watts ---- as per directions of Engineer in-charge of work.
4
-
10568
... More
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED modular down light 2'x2' /1' X 4' 34 -36watt ---- as per directions of Engineer in-charge of work.
1
-
5200
... More
Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - 18W, 6500K ---- as per directions of Engineer in-charge of work.
14
-
3570
... More
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall/ ceiling / Rafter / Girders ---- as per directions of Engineer in-charge of work.
33
-
3630
... More
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- as per directions of Engineer in-charge of work.
14
-
2100
... More
Extra length of GI pipe of class B 19mm dia for down rod. ---- as per directions of Engineer in-charge of work.
8
-
1280
... More
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. ---- as per directions of Engineer in-charge of work.
4
-
1600
... More
Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. - Remote ---- as per directions of Engineer in-charge of work.
1
-
1034
... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps DP ---- as per directions of Engineer in-charge of work.
8
-
7272
... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. - 16-25 Amps 2 pole ---- as per directions of Engineer in-charge of work.
2
-
4600
... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. - 63Amps ---- as per directions of Engineer in-charge of work.
3
-
681
... More
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) - 63Amps ---- as per directions of Engineer in-charge of work.
1
-
5300
... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu=lcs) THREE POLE FOUR POLE - 100Amps 25kA ---- as per directions of Engineer in-charge of work.
1
-
6400
... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps TPN ---- as per directions of Engineer in-charge of work.
3
-
5145
... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- as per directions of Engineer in-charge of work.
1
-
7700
... More
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter ---- as per directions of Engineer in-charge of work.
1
-
1185
... More
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- as per directions of Engineer in-charge of work.
3
-
1404
... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- as per directions of Engineer in-charge of work.
3
-
1290
... More
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. - 100Amps 4x30x6mm Aluminium Strips ---- as per directions of Engineer in-charge of work.
0.8
-
1640
... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 40x40x6mm ---- as per directions of Engineer in-charge of work.
12
-
3060
... More
Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. - 16SWG ---- as per directions of Engineer in-charge of work.
48000
-
16800
... More
Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely - 25mm ---- as per directions of Engineer in-charge of work.
22
-
616
... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. - 25x6mm Copper strip ---- as per directions of Engineer in-charge of work.
1.2
-
1149.6
... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. - 8 SWG Copper wire. ---- as per directions of Engineer in-charge of work.
12
-
1260
... More
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- as per directions of Engineer in-charge of work.
2
-
8300
... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 - 3.5 core 25 sqmm ---- as per directions of Engineer in-charge of work.
140
-
25200
... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. In existing trench/duct. On wall/Structure - 25 sqmm to 75 sqmm ---- as per directions of Engineer in-charge of work.
140
-
2170
... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc. complete.(As per Civil SR KSRB 1-2, P-7) - In soil (hard) ---- as per directions of Engineer in-charge of work.
120
-
12240
... More
Providing and laying in position 100mm dia stone ware pipe in existing trench. ---- as per directions of Engineer in-charge of work.
5
-
1075
... More
Supplying and fixing LT cast Iron pot heads suitable for 1.1KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. - 35Sqmm ---- as per directions of Engineer in-charge of work.
2
-
700
... More
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) - 50mm dia ---- as per directions of Engineer in-charge of work.
2
-
510
... More
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. - 25 sqmm Long Barrel ---- as per directions of Engineer in-charge of work.
16
-
320
... More
LED Street light : .Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 70 Watts ---- as per directions of Engineer in-charge of work.
4
-
21920
... More
Supplying and Fixing of........mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. - Using 25mm dia G.I.Pipe ---- as per directions of Engineer in-charge of work.
4
-
3100
... More
Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. - 5 KVA OFF LINE UPS Note: For item 10.2 batteries are required for backup power supply- 1) 1 KVA off line UPS one hour backup : 2 x 40 AH batteries. 2) 2 KVA off line UPS one hour backup : 3 x 80 AH batteries. 3) 5 KVA off line UPS one hour backup : 6 x 80 AH batteries. ---- as per directions of Engineer in-charge of work.
1
-
37100
... More
Supplying, installation, testing & commissioning of 12Volts ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. - 150 AH capacity ---- as per directions of Engineer in-charge of work.
6
-
135000
... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - RJ45/I.O.outlet Cat-6 ---- as per directions of Engineer in-charge of work.
14
-
2730
... More
Supplying and drawing UTP-CAT 6E LAN cable. ---- as per directions of Engineer in-charge of work.
520
-
15080
... More
Supplying & Fixing of switch mounting rack with power manager & Cable manager. - 12U with 450mm depth ---- as per directions of Engineer in-charge of work.
1
-
7600
... More
Supplying fixing of Network Switches - 24 port 10/100 Switch ---- as per directions of Engineer in-charge of work.
1
-
4000
... More
Supplying & Fixing of ... Mtrs Cat 6 Patch Cable - 2mtr ---- as per directions of Engineer in-charge of work.
12
-
2856
... More
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2Pair ---- as per directions of Engineer in-charge of work.
80
-
1160
... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - TV/Telephone socket ---- as per directions of Engineer in-charge of work.
2
-
158
... More
Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- as per directions of Engineer in-charge of work.
60
-
2100
... More
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. - 3C X 2.5Sq.mm ---- as per directions of Engineer in-charge of work.
180
-
17640
... More
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP. ---- as per directions of Engineer in-charge of work.
2
-
2760
... More
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities. ---- as per directions of Engineer in-charge of work.
1
-
745
... More
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor. ---- as per directions of Engineer in-charge of work.
2
-
800
... More
Fixing a shunt capacitor of ... KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. - 6 to 10 KVAR ---- as per directions of Engineer in-charge of work.
2
-
382
... More
Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. - 12"x12"x2" ---- as per directions of Engineer in-charge of work.
2
-
300
... More
Supplying, fixing and wiring 0 to 600Volts 96x96mm AC Voltmeter on existing panel/wood board. ---- as per directions of Engineer in-charge of work.
1
-
377
... More
Supplying, fixing and wiring 0 to 30amps Direct Reading AC analog type Ammeter ---- as per directions of Engineer in-charge of work.
1
-
387
... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- as per directions of Engineer in-charge of work.
3
-
1290
... More
Supplying and fixing cast Aluminium round or oblong type bulk head fitting with GI wire guard, glass cover with 15Watts 230V CFL lamp as required ---- as per directions of Engineer in-charge of work.
1
-
952
... More
Supplying of Single Phase Open well Mono sub pump set 1.5 HP suitable for operation on 230 volts Single phase AC supply Make- Using group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of Engineer in-charge of work.
1
-
10867
... More
Supplying and Delivery at Site 2 HP 20 Stage single phase 4 inch/100mm Submersible Pump set of approved make ISI with Motor. Suitable for operation of three Phase 50 HZ 440 Volts A.C supply fitted with required accessories complete as per the approved rate Make - Make:Kirloskar/Calama/Lubi/Atlanta/Texmo/Suguna and as per the directions of Engineer in charge of the work. ---- as per directions of Engineer in-charge of work.
1
-
19579
... More
Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure of outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor,, including cost of all materials, labour charges, HOM and testing complete as per specifications. 40mm dia. ---- as per directions of Engineer in-charge of work.
160
-
41920
... More
Supplying, installation and erection of Gate valve of 50 mm dia. ---- as per directions of Engineer in-charge of work.
1
-
1800
... More
Supplying, installation and erection of Non Return valve of 50 mm dia. ---- as per directions of Engineer in-charge of work.
1
-
1800
... More
Supplying, installation and erection of Borewell cap and clamp set. ---- as per directions of Engineer in-charge of work.
1
-
1800
... More
Supply and installation of 25 lts Water prifier as per the directions of the engineer incharge of the work ( approved make ) ---- as per directions of Engineer in-charge of work.
1
-
25000