Karnataka Power Transmission Corporation Limited Tender
... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Summary
For Aps To An Extent Of 5 Mva On 110 Kv Reference In Favour Of Divisional Railway Manager, Traction & Distribution, South Western Railway, Mysuru For Their Railway Traction Sub-station Proposed At Birur Railway Station In Kadur Taluk, Chikkamagaluru District.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
KPTCL//2021-22/TB/WORK_INDENT8179Bid Award Id
ViewTender No
KPTCL//2021-22/TB/WORK_INDENT8179Tender Authority
Karnataka Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://http://www.kptcl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
110 KV, 1250A, 31.5 KA Class Double Break Motor operated isolators ii) Live point Height 4600mm
1
-
230000
... More
Under hung mounting type without earth switch Note: TERMINAL CONNECTORS FOR ISOLATORS: (a) Rigid Type Terminal Connector Suitable for Drake ACSR-16 nos. (b) Flexible type Terminal Connector suitable for 63mm Aluminium Pipe-4 nos
1
-
255000
... More
CURRENT TRANSFORMER : Oil filled Current Transformers with rigid terminal connector suitable for Drake ACSR with marshalling Kiosk. (i) 110KV 31.5 KA CT of Ratio 400-200/1-1-1-1A Type-3 (required for line ) For Metering: Accuracy 0.2S, Burden 10VA For Metering: Accuracy 0.2S, Burden 5VA For Backup Protection: 5P20,Burden 30VA For Differential/ Distance Protection: PS Class, Knee Point Voltage Note: 110kv CT for 110kv RTSS bay shall be provided with Four cores. An additional metering core of 0.2S accuracy class shall be provided for dedicated metering required for RTSS. For this two separate secondary terminal boxes are to be provided. One shall accommodating the regular CT terminals and the other shall accommodate the dedicated metering core secondary terminals, so that the secondary terminal box accommodating the dedicated metering core terminals can be providing with sealing arrangements.
2
-
186000
... More
Metering Voltage Transformer - Single Phase, Oil filled outdoor type as per Technical Specification: (i) 110KV, VTs of Ratio 110KV / Sq.root 3/ 110V/ sq. root 3/110V/ sq. root 3 Core-1-Metering - 10VA, Accuracy 0.2 Core-2-Metering- 10VA, Accuracy 0.2
2
-
208000
... More
Surge Arresters (Porcelain Housing): (i)96KV, 10KA, Class-II, Metal Oxide Type Remarks: Surge Arresters are with Surge Monitors & Insulating Base
2
-
66000
... More
Relay and protection Panels a. 110KV Line - Duplex Type SCADA compatible NOTE: (1) The Accuracy class of metering core of CTs, VT and also trivector meters of control & relay panels shall be 0.2S class and 0.2 class for VTs irrespective of what has been indicated elsewhere in bidding documents. (2) The C&R Panels and associated panels shall match with the existing panels with respect to dimension,mimic etc. (3) The propsed C&R Panel shall be interfaced with existing
1
-
693000
... More
Station Structures: 110KV Side Station Structures (i) Station Structure Tower - 1T1 with peak (Unit weight = 0.952MT)
1
-
92228
... More
(ii) Station Structure Tower -1T 2 without peak. (Unit weight = 1.086MT)
1
-
105510
... More
(iii) Station Structure Beam suitable for fixing under hung isolator - 1B 1 (Unit weight = 0.552MT)
1
-
53524
... More
(iv) Station Structure Beam 1 B2 without under hung isolator (Unit weight = 0.465MT)
1
-
45324
... More
Mounting Structures: (i) Isolator: (a) For 110KV Isolators (ai) Live Point Hight 6350mm (unit Weight = 0.924MT)
2
-
178548
... More
(aii) Live Point Hight 4600mm (unit Weight = 0.741MT)
2
-
142842
... More
(ii) Current Transformers: (a) For 110KV CTs (unit Weight = 0.152MT)
2
-
54480
... More
(iii) Metering Voltage Transformers: (a)For 110KV VTs (unit Weight = 0.142MT)
2
-
27682
... More
(iv) Lighting Arresters (a) For 96KV LAs (unit Weight = 0.111MT)
2
-
21730
... More
(v) For Post Insulator of Rigid Bus (a)For 110KV side (unit Weight = 0.141MT)
6
-
82584
... More
RIGID BUS WITH TAPS & CLAMPS : (i)Aluminum Tube Conforming to 6340WP of IS5082/1969 (BS 1600- Sch.40) of following sizes. a. 75mm Size--- 110KV Side
78
-
100256.52
... More
Aluminum Tube Conforming to 6340WP of IS5082/1969 (BS 1600- Sch.40) of following sizes. b. 63mm Size connecting isolator to vertical tap -110KV side. Note: Quantity indicated is 5% more than the required assessed value & is rounded off to nearest multiple of 6, as it is generally supplied in length of 6M
36
-
42361.2
... More
(ii)a. Straight taps made of 63mm Aluminium Tube (BS-1600) of 1750mm vertical height for vertical portion and cross bus on 110KV side with rounded off end.
4
-
18896
... More
(iii)A. Post Insulator Clamp suitable for 75mm Aluminium pipe and post insulators solid core type 110KV side C. Sliding Type
6
-
8373.96
... More
B. Corona Bell Suitable for Aluminium Pipe of size a. 75mm on 110KV Side
6
-
4388.58
... More
(i)ACSR Conductor (a) Drake ACSR -- 110KV Side
100
-
28860
... More
(ii)Earth Wire: 7x3 .15mm steel with clamps & lugs / 50x6mm MS flats (As req)
50
-
3280
... More
INSULATORS: i. Post Insulators - Cylindrical Solid Core Insulators as per IS:5350, Part -II & III. For 110 KV Side -1 Unit / Stack: Post Insulators of Rigid Bus
6
-
60870.6
... More
ii. Disc Insulators String A. 11KV, 120KN Disk Insulator[a] 110KV Side Tension String : String of 8 Units (571.28x8 = 4570.24)
32
-
18280.96
... More
B. 11KV, 90KN Disc Insulator [a] 110KV Side Suspension String : String of 8 Unit (464.864x8 =3718.88)
16
-
7437.76
... More
Insulator Hardware & Clamps: i. Bolted Type tension clamp to suitable for Drake ACSR 120kN - 110KV Side
4
-
8114.92
... More
ii. Bolted type tension clamp to suit Lynx ACSR for 110KV lines
2
-
2279.88
... More
iii. Bolted type suspension clamp to suit Drake ACSR 90kN-110KV Side
2
-
2716.36
... More
iv. C Type Wedge connector (T- Type) Suitable for Drake to Drake ACSR. - 110KV Side
8
-
18850.24
... More
v. C Type Wedge connector (T-Type) Suitable for Lynx to Drake - 110KV Side.
6
-
11776.38
... More
(a) PVC insulatted aluminium power cable (AC Supply for lighting e.t.c) 70 Sq.mm 4 Core , with glands /lugs/ ferrules
200
-
71800
... More
AC Distribution Box (outdoor): i. AC Distribution Box Single Type , 6 terminals, 750x1350x300mm, 11/C of 100A, MCCB 20KA + 6 O/G MCB 16A + 1 O/G OF 100A, HRC Fuse.
1
-
59000
... More
PVC insulatted Copper Control cable (with lugs / ferrules): i. 19 Core x 2.5 sqmm
1000
-
511000
... More
ii 10 Core x 2.5 sqmm
600
-
171000
... More
iii. 4 Core x 6 sqmm
1500
-
244500
... More
iv. 4 Core x 4 sqmm
300
-
35100
... More
Materials for new bay integration to existing SCADA panel: a. Multi Functional Transducer (MFT)type : MFM- 02 PTR - 1kV-999.9kV/50-550V AC CTR: 1A-9999A/1A-5A, AUX. SUP-Self Powered Class: 0.2s, 1kWh=36000pulses
1
-
3950
... More
b. Opto Coupler (220 or 110V DC) including labour (market rate)
1
-
1280
... More
c. Contact multiplier relay (CMR)
1
-
450
... More
d. Terminal blocks (knife type)
1
-
20
... More
e. Current Cable-Copper core with 4.0sqmm cross section mutlistrand 7 core for CT Termination
10
-
2807.4
... More
f. Signal/communication Cables-Armoured copper core with 0.5sqmm cross section mutlistrand 10core
10
-
1277.5
... More
g. Voltage Cables-Copper core with 2.5sqmm cross section mutlistrand 4 core for PT Termination
10
-
1115.9
... More
h. Control Cables- copper core with 1.5sqmm cross section mutlistrand 10core
10
-
1274.5
... More
i. RJ-45 cable for Energy meter integration to DCU (market rate)
10
-
700
... More
Outdoor type meter box to house ETV meters, made of CRCA steel mounted on angle iron frame work ( Meter box suitable for fixing 3 ETV meters
1
-
6323
... More
HT ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD BIDIRECTIONAL as per KPTCL specifications (2 Meters : 01 No for Main Meter and 1 No for Check Meter)
2
-
38940
... More
Supply of Cast Iron pipe electrode of 100mm I.D, 13mm thick, 2.75mtr long: Grounding of equipments by Providing Cast iorn pipe of 100mm ID 13mm thickness 2.75 mtr. long with 2 part clamp out of G.I. Flat 50x6mm continuously welded around the pipe using cast iron welding electrodes (All material to be supplied by the contractor)
7
-
60424
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements