Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Opening Date28 May 2021
Closing Date14 Jun 2021
Tender Amount₹ 39,66,915 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

P31-1.providing Street Light Control Phase For Street Lights In So-1 ,so-2 (csd-1) And So-3 (rsd) Areas Of Gescom In City Corporation Ballari. 2.commissioning Of New Generator And Repair Works In Renuka Nagar Wetwell In Ballari City.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Labour -Loading and Unloading

18

-

1656

... More
27901201-2 pin cross arm with pole clam

265

-

44520

... More
Labour -Fixing of 2 Pin cross arm with insulator and Braces fixing

265

-

28090

... More
27901203-4 pin cross arm with pole clam

68

-

18496

... More
Labour -Fixing of 4 Pin cross arm with insulator and Braces fixing.

68

-

7208

... More
2798001-Fish plate with necessary plates

8

-

1200

... More
Labour -Wiring of One Circuit of LT Wiring Kit

8

-

5000

... More
2811101-Guy with Complete set

8

-

7152

... More
Labour -a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing.

8

-

1400

... More
Labour -Ordinary Soil Digging

8

-

1720

... More
281683-Spiral Earth Electrode

18

-

2970

... More
Labour -providing spiral earth electrode type earthing along with pole (without charcoal, salt etc.,)

18

-

1098

... More
283003-1.1kV Pin Insulator (Shell on

255

-

4590

... More
283053-1.1kV Pin Insulator (G.I Pin

255

-

7650

... More
283158-NO.8 Strain Insulator

324

-

5184

... More
284108-Rabbit ACSR Conductor

9890

-

360985

... More
Labour -Stringing of conductor wren, squirrel, weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.

9890

-

28384.3

... More
200105-RCC Pole-9.0M Long,145 kg WL

25

-

156450

... More
Labour -Ordinary Soil Digging

25

-

10400

... More
27901201-2 pin cross arm with pole clam

300

-

50400

... More
Labour -Fixing of 2 Pin cross arm with insulator and Braces fixing

300

-

31800

... More
27901203-4 pin cross arm with pole clam

25

-

6800

... More
Labour -Fixing of 4 Pin cross arm with insulator and Braces fixing.

25

-

2650

... More
2811101-Guy with Complete set

10

-

8940

... More
Labour -Ordinary Soil Digging

10

-

2150

... More
281683-Spiral Earth Electrode

25

-

4125

... More
Labour -providing spiral earth electrode type earthing along with pole (without charcoal, salt etc.,)

25

-

1525

... More
283003-1.1kV Pin Insulator (Shell on

500

-

9000

... More
283053-1.1kV Pin Insulator (G.I Pin

500

-

15000

... More
283158-NO.8 Strain Insulator

150

-

2400

... More
284108-Rabbit ACSR Conductor

10000

-

365000

... More
Labour -Stringing of conductor wren, squirrel, weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.

10000

-

28700

... More
289027-PVC Wire-25 Sq.mm

25

-

807.75

... More
14 778040-PVC Pipe-40 mm dia

500

-

23000

... More
280012- LT 2 pin cross arm with GI pole clam

383

-

44045

... More
Labour -Fixing of 2 Pin cross arm with insulator and Braces fixing

383

-

40598

... More
27901203-4 pin cross arm with pole clam

460

-

40020

... More
Labour -Fixing of 4 Pin cross arm with insulator and Braces fixing.

460

-

48760

... More
283003-1.1kV Pin Insulator (Shell on

360

-

6480

... More
283053-1.1kV Pin Insulator (G.I Pin

360

-

10800

... More
283158-NO.8 Strain Insulator

490

-

7840

... More
284105-Weasel ACSR Conductor

33600

-

724080

... More
Labour -Stringing of conductor wren, squirrel, weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.

33600

-

70560

... More
Supply of LED Streetlight luminaire with pressure die cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare Diffuser with Injection moulded polycarbonate materail,delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%. maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminare > IK08. Power Factor >0.9 with mains Current should not be greater than 0.1A to 0.7A & Surge Protection- Min 4KV along with Over voltage/Overload, short circuit/ miswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Over load & Short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 40W System Power consumption. LED Efficiency>130lm/w at 1W & Fixture Efficiency >80lm/w with nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED source manufacture.& Cree/Nichia/lumileds/osram make LED source. PWD ELE SR 2019-20 Page No-67 Sl .No-12.8.2 LED street light 40W

144

-

498355.2

... More
Wiring for lighting / power circuit using one of pvc insulated 1100v grade stranded aluminum unsheathed wire single core cable in open or concealed system of wiring . PWD Ele SR 2019-20, 12 Sqmm Page No-7 I.No-2.7.1

990

-

12236.4

... More
Supplying and fixing using a mm dia class A GI pipe bracket upto 2.0 mtrs long bent at suitable and fixing to this bracket 1x40w/2x40w fluirescent tubes street light fittings of all capacities to GI or CI or rail OR RCC pole /wall using suitable clamps, bolts and nuts, and wiring using suitable capacity wires. 12 Sqmm Page No-79 I.No-14.1

144

-

114948

... More
Supplying, installing, testing and commissioning of Diesel Generator set 40KVA/32KW with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 /ISO 8528 & IS 1002 / ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger,Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation.Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation. Alternator: Alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H.Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts: PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2line alphanumeric LCD display with LED Backlight.Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. Theenclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment.Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. 40KVA/32kw

1

-

491104

... More
Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility.

1

-

92185

... More
Supply of LED Streetlight luminaire with pressure die cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare Diffuser with Injection moulded polycarbonate materail,delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%. maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminare > IK08. Power Factor >0.9 with mains Current should not be greater than 0.1A to 0.7A & Surge Protection- Min 4KV along with Over voltage/Overload, short circuit/ miswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Over load & Short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 120 W System Power consumption. LED Efficiency>130lm/w at 1W & Fixture Efficiency >80lm/w with nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED source manufacture.& Cree/Nichia/lumileds/osram make LED source

4

-

37904

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 PWD Ele 2019-20 (p, no 41 I no.6.4.7) 3.5 Core 50Sqmm

80

-

24720

... More
Supplying and fixing using a 25mm dia class A GI pipe bracket upto 2.0 mtrs long bent at suitable and fixing to this bracket 1x40w/2x40w fluirescent tubes street light fittings of all capacities to GI or CI or rail OR RCC pole /wall using suitable clamps, bolts and nuts, and wiring using suitable capacity wires

3

-

2394.75

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) PWD Ele 2019-20 (p, no-26 I no.5.14.1) 100 Amps 25KA

2

-

9331.8

... More
Open Conduit System Supplying heavy gauge PVC conduit pipe 25 mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws

50

-

3347.5

... More
Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit /casing caping using 1100V grade copper conductor flexible Multi stand FRLS PVC insulated to 2x1.5 sqmm cable confirming to the GTP with a 6 Amps flush type S.P control switch shall be fixed on existing Plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood / PVC round block complete for each outlet.

10

-

2832.5

... More
Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be firmly /surface/flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs, Machine/NF screws . 10-12Way

2

-

370.8

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box

2

-

566.5

... More
Supplying and fixing of modular switch / Socket / stepped electronic fan regulator / dimmer / telephone socket etc on existing modular switch plate. Is 3854 and IS 1293. Using Group- A Materials. 6Amps one way switch

5

-

360.5

... More
6 Amps 3 way 5 pin Socket

2

-

123.6

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 PWD Ele 2019-20 (p, no 40 I no.6.4.3] 3.5 Core 25 Sqmm

100

-

15450

... More
Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 PWD Ele 2019-20 (p, no 6, I.no, 2.5.9] 4Core*2.5 Sqmm

90

-

10660.5

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required Confirming to IEC 60898 40Amps DP

9

-

12384.72

... More
Supplying and Laying double walled cottrgated [DWC] HDPE pipe including all necessary connecting sockets / couplings / tees / bends/End-caps of same materials in existing trench as per IS 14930 part- 11 suitable for drawing under Ground cables. [p, no, 63 I no, 7.20.5] 90mm OD / 76mmmm ID

26

-

8864.18

... More
Labour charges for laying of 1x1 KV class UG cable in existing trench GI pipe/stoneware pipe/ on wall / on pole as required. on the wall/ strecture 25 sqmm to 75 sqmm.

180

-

2874.6

... More
Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. [PWD Ele 2019-20 p, no, 31 I no, 5.44.4] 600x600x170mm

1

-

12443.43

... More
Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 12 mm dia.

2

-

6179.38

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. [PWD Ele 2019-20 P.44 Item no 6.18.3] 8 SWG GI wire

50

-

978.5

... More
KSRB 2-2.2 : Earthwork excavation for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(b) / 2.3.5

6.78

-

3196.43

... More
KSRB 4-1.2 : Providing in position plain cement concrete or mix M10 with OPC cement @ 220 kgs with 40mm and down size graded granite metal coarse aggregates @ 0.892 cum and fine aggregates @ 0.465 cum machine mixed, concrete laid in layers not exceeding 15 cms thick well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specification. Specification No. KBS 4.1, 4.2

3.6983

-

20394.65

... More
KSRB 5.3-3: Providing and constructing granite/trap/ basalt size stone masonry in basement with cement mortar 1:6, edges of stones chistle dressed in courses not less than 15 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13

1.6524

-

10165.48

... More
KSRB 4.1.5 : Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300 kgs with 20mm and down size graded granite metal coarse aggregates @ 0.69cum and fine aggregates @ 0.430 cum machine mixed, concrete laid in layers not exceeding 15 cms thick well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specification.

2.3804

-

13574.35

... More
KSRB 2-3:Filling available excavated earth (excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with alead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications. Specifications No. KBS 2.9

24.78

-

5229.82

... More
KSRB 6-6.2 : Providing and constructing burnt brick masonry with approved quality of non- modular bricks of standard size of class designation 75 (Machine moulded Wirecut bricks) with cement mortar 1 :6 for basement and superstructure with cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 complete

2.3063

-

13151.79

... More
KSRB 4.9.2: providing TMT Steel Reinforcement For RCC Work including straighting KBS 4.63 (P W D KCSR 2018-19 ) pg no 18

0.1068

-

7884.23

... More
KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators weighing 21kg/sqm using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12

300

-

29925

... More
KSRB 7.4 : Providing and fixing 1mm thick M.S. sheet garage door with frame and diagonal braces of size 40x40x6 mm angle Iron, using M.S. flats 30x6 mm for diagonal braces and central cross pieces 3.15mm thick M.S. Gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc., including applying a priming coat of red lead paint cost of materials, labour, HOM of machinery complete as per specifications. 1 double leaf door of size 2.4x2.4m. Specification No. KBS 7.9 / 7.12

2.52

-

5643.92

... More
CGI Sheets (PWD BCSR 2018-19 ) code 0864 pg no X

540

-

19224

... More
KSRB 15.3.1 Providing 12mm thick cement plaster in single coat with cement mortar 1:3, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications

17.028

-

3736.79

... More
Digging of trench of 0.6 mtr deep and 0.5 wide refilling the trench to the required grond level and consolidating etc., complete (as civil SR KSRB 1-2,P7) In soil hard

40

-

4202.4

... More
30HP FCMA Starter or Suitable - Supply and Delivery at site push button operated, fully automatic air break contactor front operated FCMA Starter with thermal over load relay and delay timer in sheet housing of Havells/BCH/C&S/ABB or any other make certified by the BIS along with suitable capacity air break contractor with HRC fuse for make and break. The starter should have the following. 100 Amps 4 P On load Change over Switch - 100 A, reputed make fuse base with link - 40A, 3P Power contactor - 32A, 3P Power contactor -. Over load relay of suitable rating - Star Delta timer- Phase failure relay with Dry Run Preventorr of Minilec / Proke DV's make or any other make certified by the BIS Auto/manual selector switch.- Push Button ( Stop/Start)-6 Nos Motor On/Off/Trip Indicating lamps, RED, GREEN and AMBER LAMP of rating 230 volts AC of BCH / C & S make or any other make certified by the BIS - The pumps shall be controlled by the automatic liquid level controller while the pumps run in auto mode. The electrodes shall be fixed in the wet well and the connection from the electrode shall be made to individual control panel through the cable duct. Necessary control wiring shall be made so that the pump starts / stops on auto mode. Note: The Starter shall be suitable for Six starts per hour.For Half Peak/Peak Flow Pumpsets: FCMA Starter or Suitable, It Installation & Commissioning, Packing & Freight Charges Included

1

-

120000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.