Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bengaluru Water Supply And Sewerage Board - BWSSB Tender

Opening Date12 Nov 2023
Closing Date8 Dec 2023
Tender Amount₹ 50,77,613.52 
Notes
Download

Costs

Summary

Tender For The Work Of Overhauling, Servicing, Testing And Commissioning Of 5 Mva Transformer Bearing Sl.no.2800055931 Of Cwss Stage-i Pumping Station At T.k. Halli And 5 Mva Power Transformer Bearing Sl.no.2800055926 Which Brought From Taverekere Pumping Station During Emergency At T.k. Halli

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Loading of the transformer tank with active parts and accessories at Stage 2 & 3 Substation at T K Halli.

34

-

-

... More
Transportation of transformer using 21 MT to 40 MT Truck & Trailer up to 250km. From T K Halli to Factory .

240

-

-

... More
Unloading of the faulty transformer tank with active parts and accessories at Firm's site.

34

-

-

... More
Dismantling transported Transformer for joint inspection at repairer's premises including all activities such as opening of top cover, de-tanking of core and winding, separation of HV/LV coils, conducting preliminary test required for assessment of repair work to be undertaken, dismantling core etc., in the presence of BWSSB authorized representative.66/11kV Class – 5 MVA

2

-

-

... More
Cleaning, repairing and painting inside the transformer tank with hot oil bath and acid proof epoxy paint and painting outside the tank with enamel paint after thoroughly cleaning including the cost of material the painting of radiator at firm. 66/11 kV class - 5 MVA

2

-

-

... More
Reconditioning of accessories like Radiators, Conservator by hot air circulation along with pressure test of radiators and reconditioning of Transformer mounted mechanical relays 110 kV and above class Transformer

2

-

-

... More
Rubberized corksheet/Neotrene rubber gaskets as necessary, for complete Transformer 110kV and below Class

2

-

-

... More
Drying of Power Transformers Drying of Power Transformer at factory: Drying of active parts of Transformer in Oven 110kV and below class Transformer

2

-

-

... More
Tanking the assembly (repaired Transformer) giving connection providing new gasket, insulating materials confirming to IS putting back the cover tignting the fixtures, fixing the bushing etc, including the cost of all materials like gasket, insulating material, bold and nut etc and labour other accessories as repaired works to facilitate the testing.66/11kV Class - 8 MVA

2

-

-

... More
Supply of EHV Grade Electrol Oil

18000

-

-

... More
Filling of oil to main tank and OLTC tank, filtering the oil including filtering till attainment of prescribed BDV value including labour, filtering equipment along with accessories.

15850

-

-

... More
Work of repairing of diverter switch and replacement of resistance upto 66KV/6.6KV 8MVA Transformer as specified below: Removing the supply connection of diverter switch draining out the diluted oil of OLTC chamber, removing the diverter switch one by one carefully by using tripped and chain pulley block. Dismantling the diverter switch unit, removing the worn-out resistance from the diverter switch Supply and fixing of new resistance of same capacity as original to the diverter switch without disturbing the other running equipment, cleaning the diverter switch housing chamber to remove the carbon deposit, lowering the repaired diverter switch inside the housing chamber and aligning the centre shaft by using link nut, bolt and washers tighting of resistor conductors carefully without causing damaged to the nearby the contact refilling the good quality high BDV value insulation oil to the diverter switch housing chamber (oil will be supplied by the department) adjusting the micro switch NO, NC contacts and lifting liver for its proper function and covering the chamber by fixing the lid on the top. Testing the operation of tap changing system by giving upto 440 Volts supply from tap position 1 to 25 after satisfactory charging over all 25 taps in forward and reverse direction.

4

-

-

... More
Work of repairs/servicing and overhauling of on load tap changer (OLTC) of upto 66KV/6.6KV 8MVA transformer as specified below: Painting of transformer including platform CTS etc., with one cost of red oxide to the rusted portion of transformer, 2 coats of M/s grey enamel paint, RYB color paint to CT caps for identification etc., Rates should quote inclusive of cleaning of the transformer of all sizes.

2

-

-

... More
Test to be carried out on Power Transformers. Testing the power transformer for IR Values, voltage Ratio at all taps, short circuit test, magnetic balance, Magnetizing current measurement at rated voltage from LV side. - for 8 MVA Power Transformer at Factory after repair of the transformer.

2

-

-

... More
Loading of the repaired transformer tank with active parts and accessories at Firm's site.

50

-

-

... More
Transportation of transformer using 21 MT to 40 MT Truck & Trailer up to 250km. From factory to T K Halli.

220

-

-

... More
Unloading of the repaired transformer tank with active parts and accessories at Stage 2 & 3 Substation at T K Halli.

50

-

-

... More
Assembly of transformer parts like bushing, radiators, draining oil from the transformer etcfor the total weight of the transformer. Weight of 8 MVA power transformer - 22.5 MT

13.6

-

-

... More
WTI with 4 contacts, 15 meters capillary length with built in CCU RTD and external remote indicator, range 0-150 deg C, with SCADA compatibility)

2

-

-

... More
OTI with 2 contacts, 15 meters capillary length with built in CCU, RTD and external remote indicator range 0-150 deg C, with SCADA compatibility

2

-

-

... More
Main Tank Conservator Power Transformer:MOG

2

-

-

... More
Transformer Mounted Protection in Transformer: Buchhloz Relay

2

-

-

... More
Transformer Mounted Protection in Transformer:Oil Surge Relay

2

-

-

... More
Transformer Mounted Protection in Transformer: Pressure Relief Device (PRD or PRV)

2

-

-

... More
Dehydrating Silicagel Breather Assembly.

4

-

-

... More
Moving the (faulty) transformer from the plinth. Weight of 5 MVA power transformer - 22.5 MT Distance to be moved -50 m 22.5 MT x 50 m = 1125 MT/m

2250

-

-

... More
Test to be carried out on Power Transformers. Testing the power transformer for IR Values, voltage Ratio at all taps, short circuit test, magnetic balance, Magnetizing current measurement at rated voltage from LV side. - for 8 MVA Power Transformer at Factory after repair of the transformer.

2

-

-

... More
Wiring of Transformer marshaling box, bucholtz relay, fixing Thermometer, OLTC up to control panel and assisting in testing and commissioning by RT/MT Firm engineers. 5 MVA to 6.3/8 MVA Power Transformer

2

-

-

... More
Bushing for power transformer condenser type OIP bushing for power transformer - 72.5 kV/800Amps

6

-

-

... More
Terminal connector Clamps for Bushings for Power Transformer: Suitable for 72.5kV class bushing to suit Twin Moose / Single Drake Conductor.

6

-

-

... More
Conventional Bushing with metal parts for Power Transformers

8

-

-

... More
Control Valves for Power Transformers: Drain Valve (100mm to 200mm Siz) suitable for: 110 kv and below class

6

-

-

... More
Top / Bottom Filter Valve (50mm to 100mm size) suitable for: 110 kv and below class Transformers

6

-

-

... More
Marshalling Box (With IP 55 degree of protection, TBs, Earthing Arrangement, mounting arrangements for various components etc.,)

2

-

-

... More
Terms and Conditions

-

-

-

... More
All the works should be carried out as per KTPP Act and as per specification or as directed by the Engineer- in-charge.

-

-

-

... More
Rates quoted above are including clearance of the site (prior to commencement of work and its completion) in all conditions of site, moisture, weather etc.

-

-

-

... More
The Board reserves the right to bifurcate the work and entrust if warranted and if found expedient and advantageous to the Board of lowest approved rates.

-

-

-

... More
The BWSSB reserves the right to accept or reject any OR all of the tenders without assigning any reason.

-

-

-

... More
Rates should be Exclusive of all taxes, insurance and freight charges.

-

-

-

... More
Rates should be quoted by the contractor/firm on Item war basis both in figures and in words.

-

-

-

... More
The payment will be made after completion of work.

-

-

-

... More
The firm should upload turnover certificate which is counter signed by chartered accountant.

-

-

-

... More
The firm should have requisite man power, machineries at their disposal to complete the work within the stipulated period, the necessary documents should be enclosed.

-

-

-

... More
The firm has to upload "Form of tender" in the standard format or otherwise the tender will be liable for rejection.

-

-

-

... More
Rates are Exclusive of GST & other taxes & duties.

-

-

-

... More
Signature of the Contractor

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.