Bangalore University Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bangalore University Tender

Works
Opening Date29 Oct 2024
Closing Date19 Nov 2024
Tender Amount₹ 2,82,085.36 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick -do- 30 mm thick Both side teak (P.No. 105, 12.57.1, V-2, SR:2023-24)

3.2

4447

14231.36

... More
code05 - Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (P.No. 104, 12.54, V-2, SR:2021-22)

11.6

349

4057.68

... More
code06 - Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.- with one side prelam (P.No. 104, 12.55.2, V-2, SR:2023-24)

3.12

2244

7001.28

... More
code07 - Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.47, V-2, 8.34.1 PWD SR:2021-22)

16

58

932.8

... More
code08 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.48, V-2, 8.40 PWD SR:2023-24)

17.28

126

2185.92

... More
code09 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, V-2, 8.2.1 PWD SR:2023-24)

16.8

324

5451.6

... More
code10 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (P.No.48, V-2, 8.39 PWD SR:2023-24)

28.8

139

4023.36

... More
code11 - Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, havingtensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (P.No. 149, 15.2, V-2, SR:2023-24)

137.84

810

111746.888

... More
code12 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregate (P.No.15,2.1.4,V-1,SR:2023-24)

5

6838

34193.5

... More
code13 - Supplying of 1.1 KV LT UG cable XLPE or Heat esistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity as per IS-3975 (P.No. 13 of 81, Sl. No. 207, I. 32.11) (BESCOM SR 2023-24)3.5 core 50 sq mm

0.095

180

17.1

... More
code14 - Labour Charges for laying of 1.1 kv class UG cable in existing trench GI pipe /stone ware pipe/on wall/on pole as required. 25 sq mm to 75 sq mm (P.41, I. 6.5.2) (PWD ELE SR 2019-20) In existing trench

48

15

744

... More
code15 - Labour Charges for laying of 1.1 kv class UG cable in existing trench GI pipe /stone ware pipe/on wall/on pole as required. 25 sq mm to 75 sq mm (P.41, I. 6.5.2) (PWD ELE SR 2019-20) On wall/Structure

32

35

1120

... More
code16 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work (P.06 1.6) (PWD civil vol -01 SR 2023-24)

48

484

23232

... More
code17 - Supplying and fixing L.T cast iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc., (P No. 42 I. 6.10.3) (PWD ELE. SR 2019-20) 25 sq mm

2

350

700

... More
code18 - Supplying and fixing of porcelein fuse channel with cutout on existing wooden/panel using ecessary nuts, bolts and washers. (P.No. 14 of 105, Sl. No. 207, I. 32.11) (PWD Ele SR 2023-24)

6

691

4146

... More
code19 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P. No. 5 of 105 I. 2.3.2, 2.3.3, 2.3.4) (PWD ELE. SR 2023-24)4 Sq mm

90

59

5310

... More
code20 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (P. No. 8 of 105 I. 3.5.5, 3.5.6) (PWD ELE. SR 2023-24) 8 module

4

284

1136

... More
code21 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (P. No. 8 of 105 I. 3.5.5, 3.5.6) (PWD ELE. SR 2023-24)10-12 module

6

344

2064

... More
code22 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P. No. 9 of 105 I. 3.6.1, 3.6.3, 3.6.4, 3.6.7,3.6.9, 3.6.10) (PWD ELE. SR 2023-24)6Amps one way Switch

40

102

4080

... More
code23 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P. No. 9 of 105 I. 3.6.1, 3.6.3, 3.6.4, 3.6.7,3.6.9, 3.6.10) (PWD ELE. SR 2023-24) 6Amps 3way socket

8

171

1368

... More
code24 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P. No. 9 of 105 I. 3.6.1, 3.6.3, 3.6.4, 3.6.7,3.6.9, 3.6.10) (PWD ELE. SR 2023-24)Stepped fan Regulator

4

357

1428

... More
code25 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P. No. 9 of 105 I. 3.6.1, 3.6.3, 3.6.4, 3.6.7,3.6.9, 3.6.10) (PWD ELE. SR 2023-24)16Amps one way switch

2

180

360

... More
code26 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P. No. 9 of 105 I. 3.6.1, 3.6.3, 3.6.4, 3.6.7,3.6.9, 3.6.10) (PWD ELE. SR 2023-24)16Amps universal socket

2

236

472

... More
code27 - Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (P. No. 43 of 105 I. 11.3.2, 11.3.3) (PWD ELE. SR 2023-24)

6

690

4140

... More
code28 - Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. (P. No. 56 of 105 I. 13.7) (PWD ELE. SR 2023-24)

6

122

732

... More
code29 - LT 3 Phase 4 wire CT operated DLMS Complaint Energy meter, 1.0 Accuracy class (Used for LT-2, LT-3 & LT-5 installations upto 25 HP/18KW) (Item No. 53.04) (ESCOM SR 2023-24)

1

3396

3396

... More
code30 - Supplying, Wiring & Fixing Earth electrode for Grounding conduits,I.C.cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr. Long buried in a pit..The pit should be filled with equal proportion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size asper ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 12mm dia. (P. No. 54 of 105 I. 12.56) (PWD ELE. SR 2023-24)

2

3510

7020

... More
code31 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. (P. No. 46 of 105 I.11.8.4, 11.8.6) (PWD ELE. SR 2023-24) 90watts

2

8860

17720

... More
code32 - Supplying and fixing …mm dia class GI Pipe bracket upto 2.7 mtrs long terminated with reducing collar of 40x25mm to which extra pipe of 175 mm length is fixed for fixing SV street light fitting of all capacities on rail/RCC/wall /tubular pole sing suitable clamps, bolts , nuts and wiring using suitable capacity wires. (P. No. 56 of 105 I.13.1.1) (PWD ELE. SR 2023-24)

2

978

1956

... More
code33 - Fixing SVL flood light fitting over existing pole including clamps, bolts, nuts and wiring using suitable capacity wires. (P. No. 56 of 105 I.13.5) (PWD ELE. SR 2023-24)

2

162

324



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.