Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Water Resources Department - WRD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Feb 2025
Closing Date7 Mar 2025
Tender Amount₹ 16,93,956
Costs
EMD
₹ 33,900Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_WRD_98796_1Tender No
WRD/SMP/MD/CHANDIL/02/2024-25Tender Authority
Water Resources Department ViewPurchaser Address
-Website
http://jharkhandtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Erection of metallic pole of following lengthin cement concrete 1:3:6(1 cement:3coarse:6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc.as required(Above 6.5 metre and upto 8.0 meter)
5
3066
15330
... More
S.I.T.E of 120 W LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltsge 100-270V AC, 50HZ. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be omplete with all neccssary accessories as required(Make Havells,Philips,Surya, crompton, Bajaj only)
33
8163
269379
... More
Supply of PVC/XLPE insulated PVC sheathed heavy dutty, armoured electrical cable with aluminium conductor for working voltage up to 1100 volts.(conforms to IS:1554, Part-1), 3.5 core 35 sq. mm (Make Havells, KEI, Finolex, R R Kabel, polycab only)
230
396
91211.1
... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq. mm direct in ground including excavation, sand cushioing,protective covering and refilling the tranch etc as required.
230
207
47610
... More
Supply and fitting of Outdoor stand mounted feeder panel with 63A TPA MCB inomer, 63amp TP contactor automatic switching of liuminaries, power tool control inommer outgoing terminal etc as requried.
1
31956
31956.1
... More
Supply and fixing 6 amps to 32 amps rating, 240 volts, 10 KA,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.(6/32 amps, single pole, DP)(Make Schneider, Legrand, Havells, Anchor, ABB only)
29
182
5278
... More
Earthingwith G.I earth pipe 4.5 mtr long,4omm dia includingmaccessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. With charcoal and salt as required
2
4447
8894
... More
Painting with aluminium paint of approved brand and manufacture to give an even shade. (2 X 3.14 X 0.145 X 3.04m + 2 x 3.14 x 0.12m x 1.79m + 2 x 3.14 x 0.1 x 2.22m) x 29nos. Street existing light poles
323.59
120
38950.53
... More
Supplying ,installation testing commissining of 1200mm(48") ceiling fan 3 blades confirming to IS:374:2019 Including wiring the down rods of standerds length(up to 30 cm) with 1.5sq.mm.FR PVC insuladed,copper wire suitable for 230v 50Hz, single phase supply etc. complete as required.
2
1620
3241.58
... More
S.I.T.E of 100W LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 Protection) in existing pole/pipe for supply voltage 100-270v AC, 50Hz Luminarie shall be confirm to IS:10322 Part-5/section-5 and shall be complete with all neccssary accessories as required.
4
9523
38092
... More
supply installation testing commissining of High mast Light in mechanical work shop. Supply of 20 mtr, high mast in two section construction S355 grade as per BS-EN 10025 Top dia 150mm, bottom dia 410 mm, plate thickness 3mm, 20 mm side polygon galvanisation as per BSEN ISO 1461, base plate dia 570 mm base plate thickness 25 mm GI single spike lighting protection, maximum wind speed 47m/s with 8 nos foundation bolts of PCD 490mm TS 600/30MM Dia/850mm long, Luminaries carring Materials for 50NB ERW class B- M.S Pipe dia of carriage ring 535mm (ID) with 6 arm,welded, 2 sections having capacity up to 12 luminaries. Trailing Cable; 5 core 4 sq.mm PVC flexible copper conductor which/power tool : Double drum SWL 750 Kg with 1 HP 6 pole single speed integle motor rope : Grade AISI 316,7/19 construction , dia 6mm, BLC 2350 X 2 having 2 nos of continues rope . Aviation obstruction light : twin dome aviation obstruction light LED Type as required. (But excluding Feeder piller)
1
228060
228060.8
... More
ITC of the high mast and light fixture with the help of suitable toola and plants wiring material like PVC insulated PVC sheathed flexible cable of suitable copper conductor lugs, MCB and all labour & construction of shallow foundation with M25 grade onrete for the high mast considering safe soil bearing capacity of 10T/mtrs sq. for 20M High mast
1
120984
120984.9
... More
S.I.T.C of 240 LED Flood lighting luminarie with pressure die cast housing and toughtened glass cover (IP 66 protection) in exixting pole for supply voltage 100-270V AC, 50Hz , Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all necessary accessories as required (Make Havells, philips, Surya, Crompton, Bajaj only)
12
20788
249456
... More
Supply of PVC/XLPE insulated PVC sheathed heavy dutty, armoured electrical cable with aluminium conductor for working voltage up to 1100 volts.(conforms to IS:1554, Part-1), 3.5 core 25 sq. mm (Make Havells, KEI, Finolex, R R Kabel, polycab only)
45
321
14483.7
... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq. mm direct in ground including excavation, and refilling the tranch etc as reqd. but excluding sand cushioing and protective covering..
45
87
3915
... More
Supply and fitting of Outdoor stand mounted feeder panel with 63A TPA MCB inomer, 63 amp TP contactor automatic switching of liuminaries, power tool control inommer outgoing terminal etc as requried.
1
22415
22415.25
... More
Earthingwith G.I earth pipe 4.5 mtr long,4omm dia includingmaccessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. With charcoal and salt as required
2
4447
8894
... More
Supply and laying 8 5WG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc as required.
10
140
1400
... More
SOLAR PANEL IN ROOF TOP OF MECHANICAL OFFICE Supply installation ,testing commissioning of solar photovollaio grid corrected roof top plant confarming to MNRE specifications(a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years, (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ system must be warranted for their out peak wayy capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b)power conditioning unit (PCU) of 350-800 V DC Input Voltage range and 400V AC, Three phase,4 wire, 50Hz+/-2.5Hz output voltage suitable to generate AC. (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient tempertature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency. (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g)Connection & interconnection by supply & fixing required size XLPE insulated copper conduction 1.1 KV grade connection armoured power and cable b/wn solar moduled main power cable to grid supply PVC unit along with supplying & giving of necessary channel/conduct lays and other accessories etc as required.
3
47961
143883
... More
Add GST @18%
1
255841
255841.58
... More
Add Labour Cess @1%
1
16771
16771.84
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%