Military Engineer Services Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical Goods and Equipments
Electrical and Electronics
Water Storage And Supply
Eprocure
Opening Date17 Oct 2024
Closing Date14 Nov 2024
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for taking up/ down of GI pipes including all fitting from trenches/walls /floors and connections etc complete all as specified and directed at site.

-

-

-

... More
15 mm bore dia

292

-

-

... More
20 mm bore dia

298

-

-

... More
25 mm bore dia

426

-

-

... More
40 mm bore dia

374

-

-

... More
50 mm bore dia

600

-

-

... More
80 mm bore dia

315

-

-

... More
100 mm bore dia

225

-

-

... More
CI/DI 100 mm bore dia

220

-

-

... More
Relaying only GI tubes any grade in trenches materials obtained from Item No.4 here-in-before after cleaning or rerunning the old screw threads with replacement of unsv fittings and fixtures for following size of complete as directed.

-

-

-

... More
15 mm dia

32

-

-

... More
20 mm dia

28

-

-

... More
25 mm dia

36

-

-

... More
40 mm dia

24

-

-

... More
50 mm dia

150

-

-

... More
S&F tubes,' medium grade', galvanized, with all fittings; laid in trenches of following sizes:

-

-

-

... More
15 mm bore dia

260

-

-

... More
20 mm bore dia

270

-

-

... More
25 mm bore dia

390

-

-

... More
40 mm bore dia

350

-

-

... More
50 mm bore dia

450

-

-

... More
80 mm bore dia

315

-

-

... More
100 mm bore dia

225

-

-

... More
S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, for following bore dia for the following bore dia : (Note : Gate valve fixed and removed at different places.)

-

-

-

... More
15 mm dia

50

-

-

... More
20 mm dia

30

-

-

... More
25 mm dia

40

-

-

... More
40 mm dia

15

-

-

... More
50 mm dia

15

-

-

... More
M&L for Bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc.)Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) all as specified and as directed , upt 150mm bore dia collars, caps and plugs

350

-

-

... More
M&L for Rubber gasket joint for flange joint all as specified and as directed , upt 150mm bore dia

25

-

-

... More
S&F replacement cast iron sluice valve with flanged ends, confirming to IS-780 type PN-1.6 cast iron body with CI wheel brass spindle, joints with rubber gaskets including bolts nuts and washers complete with ISI mark size 100 mm CI line in position, all as specified and directed.

8

-

-

... More
Description all as per Item No. 8 above but size 80mm bore pipe

5

-

-

... More
Construction of Brick masonary valve pit chamber of size 1200mmx1200mmx1200mm (internal dimension) including necessary excavtion and earth work in any type of soil,angle iron frame ms sheet cover with locking arrangements incl painting two coats symthetic enamel paint over a coat of red oxide primer complete all as specified.

8

-

-

... More
Construction of Brick masonary valve pit chamber of size 900mmx900mmx900mm(internal dimension) including necessary excavtion and earth work in any type of soil,angle iron frame ms sheet cover with locking arrangements incl painting two coats symthetic enamel paint over a coat of red oxide primer complete all as specified.

9

-

-

... More
Supply and laid Ductile iron pipe S/S including special Class "k-7" 100 mm dia complete all as specified and directed by EIC.

220

-

-

... More
M&L for dismantling of 50 HP capacity motor from 3 phase centrifugal pump set & segregating to its parts for repairs and M & L rewinding of motor with super enameled copper wire of same wire gauge of existing wire including varnishing, turning and polishing to the shaft and / or rotor, including replacement of suitable bearing and spare parts ( if required ) etc incl removing old unsv burnt wire complete & refitting motor after completion of work including testing of motor of following capacity complete all as specified and directed by Engr-in-charge Note : (i) S&F cost ' of bearing and terminal plate, shaft sleave impetor set will be measured and paid seperately against supply only under below respective items .ii) Rate for transport site to work shop and work shop to site are deemed to be included in the quoted rates.

2

-

-

... More
Supply only ball bearing suitable for 50 HP motor complete all as specified & directed at site.

2

-

-

... More
Supply only coupling suitable for 50 HP Pump set including necessary nuts, bolts, washers, rubber bush etc complete all as specified and directed at site.Note : the rate quoted above are deemed to be included the cost of minor alteration to the shaft of the Pump set for fixing of above coupling complete

2

-

-

... More
Supply only terminal plate with brass nuts,washers suitable for 3 phase 50 HP pump motor complete all as specified and directed at site.

2

-

-

... More
Supply only shaft sleeve suitable for centrifugal pump set of capacity 50 HP complete all as specified and directed at site.

2

-

-

... More
Supply only Impeller set suitable for centrifugal pump set of capacity 50 HP complete all as specified and directed at site.

1

-

-

... More
M&L for dismantling centrifugal pump and motor 50 HP three phase from foundation with base plate, nut, bolt, to shift safe place and cleaning pump motor part with greasing, oiling, gland dori, air release valve, pipe and minor repair and fixing in new foundation with new nut, bolt, elect connection complete with running condition without vibrating the foundation complete all as specified and as directed by Engr-in-charge.

2

-

-

... More
S&F in repair, star delta starter fully automatic suitable for electric pumpset motors 50 HP cap 3 phase 415volts, comprising of main star delta starter with 'D' range contractor & electric star delta timer in S.S. enclosure complete all as specified & directed by Engineer-in-charge. Make : C&S , L&T / Siemens of equivalent size and specification.

1

-

-

... More
M&L for seven stage cleaning and sterilization of inside the RCC/Underground/semi underground/Over head tanks/ Sedmentation / clear water sumps of following capacity as mentioned against Ser Item No 23.02 & 23.03 through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: Any E-in-C branch approved ageny :- (a). First Stage is to drain out the water by using exit valve or our own high capacity dewatering system or by own arrangement approved by Engr -in -Charge. (b). Second stage is cleaning all the algae formation and removing the accumulated silt from bottom bed and side walls by brushing with nylon brush or scrubbing the walls of the tanks or removing other sticky or foreign materials from adhering surfaces and washing inside surfaces with TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company. (c). Third stage is fresh water cleaning by high speed jet pump with a pressure of 5 psi (d). Fourth stage and first bacteria screening and degermification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified branded halogen compound. (e). Fifth stage is cleaning the floor of water tank by heavy duty industrial vacuum cleaner. (f) . Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree within the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65 . NOTE:- (i) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69 BEFORE CLEANING, (ii) PAINTINGS OF INFORMATION BOARD - AFTER COMPLETION OF CLEANING OF EVERY TANK WITH TWO COATS SYNTHETIC ENAMEL PAINT (1ST GRADE QUALITY) (A) INCLUDING WRITING LETTERS & FIGURES BOLDLY AND SOLIDLY (B) TANK CLEANED ON _____( DATE OF CLEANING) & (C) CA NUMBER (D) NAME OF CONTRACTOR

-

-

-

... More
(E) NAME OF AGE E/M WITH PHONE NUMBER (F) NAME OF JE E/M WITH PHONE NUMBER (G) HAVING A HEIGHT OF ALL LETTERS 10 CM WITH OBLITERATING THE OLD ONE AND (H) PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. (iii) ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE.) (iv) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID ENTERING SCALES AND THE SAME SHALL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE PROVISION . (v) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM 03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (vii) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. (viii) Every stage of cleaning shall be videographed along with photos clearly depicting the below. Tank wise compact disk with photos and videos will be submitted along with the PVs & bills for processing the payment:- (a) Equipment & manpower involved in cleaning (b) Chemical and quantity involved in cleaning THE WORK SHALL BE CARRIED THROUGH SPECIALIZED AGENCIES APPROVED BY E-IN-C BRANCH/ CENTRAL COMMAND.

-

-

-

... More
Inside overhead reservoir of capacity 25000 gallons .

1

-

-

... More
Inside UG/Semi UG Sump reservoir capacity of 20000-30000 gallons

1

-

-

... More
S&F in replacement Tyre Type Automatic Flexible Cushion Couplings – TC Series of TC/P/014 and TC/Q/013 suitable for centrifugal pump sets.

2

-

-

... More
S&F in replacement GREASED AND GRAPHITED Gland packing made from natural fiber, lubricated and graphited used in centrifugal pumps size of 10mm and 12mm.

30

-

-

... More
S&F in replacement, to water level indicator for over head tanks including replacement of brass pully copper float steel wire rope of required size etc. including painting of water level indicator and making good of water level indicator and marking distinctively the scale of water level by synthetic enamel paint all as directed by engineer in charge.

2

-

-

... More
M&L for repair existing leakage of GI pipe line 15 to 25 mm by welding or cutting and making threading for insertion nipple, socket, union socket, pipe piece up to 01 mtr for any place complete all as specified and directed by Engineer-in-charge.

25

-

-

... More
M&L for repair existing leakage of GI pipe line 40 to 80 mm by welding or cutting and making threading for insertion nipple, socket, union socket pipe piece up to 01 mtr for any place ie. Pokaran/Gomat/Khetolai/Lathi/Nachna complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
M&L for repair existing leakage of CI pipe line 100 mm by excavation, cutting of pipe for insertion new pipe, if required change the joint, MS round plate clip set for any size of pipe at any place complete all as specified and directed by Engineer-in-charge.

10

-

-

... More
S&F in repair, Brass foot valve ball type heavy duty suitable for 100 mm bore pipe line including dismantling of old unserviciable foot valve any type and make from suction pipe of pumpset at any place complete all as specified and directed by Engineer-in-charge. Note : (a) The rate quoted for above item are deemed to be included the cost of minor repair/alteration to the pipe or fixing of above foot valve complete. (b) The all complaint should be done within two days of any place/location other wise Rs. 500/- panality recovered from the contractor.

2

-

-

... More
M&L for spray painting of Pump & Electric motor at site with one coat of weather proof grey synthetic enamel paint after removing all dust rust carbon and oily spots, including well preparation of surfaces and writing / marking SM / MES No as 25 mm stencil with white paint complete all as specified including painting of suction & delivery pipe lines inside the pump house and arrow marking of water direction all as specified and directed for pump set rating of 20 HP to 75 HP at any place complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
Taking down old starter and S&F of soft starter variable frequency drive type panel suitable for 50 HP centrifugal pump motor set 3 phase, 415 volt, 50 HP/37 KW alongwith suitable contactor rating , over load relay fitted on CRCA sheet box including connecting copper wire 25 sqmm single core of suitable length for connecting from starter to pump-motor set complete all as specified & directed. Make : Make: L&T/Hitachi/Danfoss/ABB/Siemens (a) VFD drive 50HP/37KW (b) AUX. Contactor 9A with 2NO+2NC For Logic-02 (c) Start/Stop Push Button-02 (d) Ampere Meter-01 (e) Volt Meter-01 (f) Aluminium Bus Bar 400A (30 x 10mm) TPN-03 (g) MCCB Incomer 160A/4P-01 (h) Termical block + wiring (j) Cable Duct (k) R, Y, B Indicating LED Lamp-03 (l) Indicating LED Lamp-On. Off & Trip-03 (m) Sheet: CRCA Sheet Steel 2mm Powder Coated (n) Potentio Meter-01 (o) MCB 6A for logic-04 (p) Cooling Fan-01 (q) Insulator one lot (r) Gasket -A lot (s) Control T/F: 440/220VAC-01 Note : Old starter will be deposted in MES Yard Jamshedpur

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.