Military Engineer Services Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date8 Feb 2023
Closing Date7 Mar 2023
Tender Amount₹ 40,29,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVN OF 250 KVA TRANSFORMER WITH ALLIED SERVICES AND UPGRADATION OF LT LINE FOR EME BN AT DIPATOLI
PROVN OF 250 KVA TRANSFORMER WITH ALLIED SERVICES AND UPGRADATION OF LT LINE FOR EME BN AT DIPATOLI
PROVN OF 250 KVA TRANSFORMER WITH ALLIED SERVICES AND UPGRADATION OF LT LINE FOR EME BN AT DIPATOLI
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply fixing and fabricating tray holding cross arms FI clamps support U clamps strips and back plates fabrication from structural steel section incl nut bolts washer bars etc of required size and thickness for supporting of cable tray by welding incl bending or welding cold or hot, drilling holes for bolt in any shape or size indicated or included of one coat primer coat under one finishing coat of black paint complete to support the cables complete all as specified and directed

8

-

-

... More
S&F connect lightening arrestor non linear, pole type MCOV 11 KV discharge capacity 65 KA, with all fittings suitable for 11 KV electric working pressure including strap, bolts, nuts and washers etc complete all as specified and directed.

1

-

-

... More
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 95 mm, complete all as specified and directed

695

-

-

... More
Material & Labour cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed

2

-

-

... More
Material & Labour cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.

1

-

-

... More
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.00 Meters long) rate include necessary excavation, earth work & PCC work complete all as specified and directed.

2

-

-

... More
S&F air break switch (GOD) vertical/horizontal, double break type triple pole mechanically operated mounted on double insulartors and steel frame with operating mechanism linked with ground level operating GI rod 25mm dia medium grade. GOD suitable for current rating upto 400 amps and suitable for HT 11 KV including connecting complete with locking arrangement complete all as specified and directed.

2

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core, complete all as specified and directed

250

-

-

... More
Supply, installation, testing and commissioning of new out door type LT feeder pillar box complete with 4 Nos heat shrinkable insulated copper bus bars of 800 Amp rating including all connections with busbar strip. Incoming : (i) MCCB four pole 415 volts, 50 Hz, 500 Amps, breaking capacity 50 KA with adjustable thermal & adjustable magnatic protection release = 01 No (ii) Phase indicator lamp RBY complete with copper control wiring = 02 set of three, (iii) Panel mounted multifunctional digital meter 3 lines LCD display in 96x96 Sqmm flush mounted case accuracy class-I. complete with all accessories including 3 Nos 200/5A CT for each phase. Outgoing :- (i) MCCB FP 415 volts, 160 Amps, breaking capacity 16 KA with adjustable thermal adjustable magnetic protection release = 06 Nos.

2

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core, complete all as specified and directed

470

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete all as specified and directed

208

-

-

... More
Excavation in trenches not exc. 1.5 m wide and not exec 1.5 mtr in deep for foundation etc or for shafts, wells, cesspits, mainholes, pierholes etc in any type of soil for foundation and getting out and levelling of bottom surface to required level complete all as specified and directed

426.8

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide and depth beyond the first 1.5 mtr for foundation ect. Or for shafts, well, cesspits, mainholes ect. In any type of soil for foundation and getting out and levelling of bottom surface to required level complete all as specified and directed

0.27

-

-

... More
Material and labour for river washed and screened, dry sand for filling in trenches/sub stations below and around underground cables for cushioning of cables etc complete all as specified and directed

118.32

-

-

... More
Returning filling including leveling, watering and well ramming soil in layers not exceeding 1.5 m above the starting level, complete all as specified and directed

281.74

-

-

... More
Removing the excavated materials not exceeding 50 m and depositing where directed at level not exceeding 1.5 m above the starting level, complete all as specified and directed

145.09

-

-

... More
Supplying and laying unreinforced precast cement concrete cable covers, Class HV, Type-1, Flat, size 300 mm x 180 mm x 40 mm in trenches for cable protection, embossed with "HT ELECTRIC" on the top surface complete all as specified and directed

3279

-

-

... More
Supplying and laying unreinforced precast cement concrete cable covers, Class LV, Type-1, Flat, size 250 mm x 150 mm x 40 mm in trenches for cable protection, embossed with "LT ELECTRIC" on the top surface complete all as specified and directed

6180

-

-

... More
S&F Cable route indicator / Marker made up of PCC Block in cement mortar (1:3:6) (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with "DANGER / 11 KV CABLE /MES or DANGER/ 11 KV HT JOINT/ MES" embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and directed.

16

-

-

... More
S&F Cable route indicator / Marker made up of PCC Block in cement mortar (1:3:6) (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with "DANGER LT CABLE " embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and directed.

26

-

-

... More
M&L for trenchless boring under road crossing/foot paths etc complete all as specified and directed.

40

-

-

... More
Supply and laying in replacement of GI pipe 80 mm bore, Light grade (for cable protection) ISI marked complete all as specified and directed.

65

-

-

... More
M&L Cement Concrete PCC (1:4:8) (40 mm graded aggregate), type D2 as concrete in foundation of Poles and filling and mass concrete etc, including formwork (as if required), complete all as specified and directed.

2.85

-

-

... More
M&L Cement Concrete PCC (1:3:6) (20 mm graded aggregate) as in coping of pole etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed

0.98

-

-

... More
M&L Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white,with letters, figures and conventional skulll and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT, 25 x 20 cm complete all as specified and directed.

4

-

-

... More
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.