Military Engineer Services Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Sep 2024
Closing Date9 Oct 2024
Tender Amount₹ 47,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fix in replacement MCCB TPN 415 volts 250 Amps 50 Hz Adjustable type, with breaking capacity 25 KA ,complete all as specified and directed.

11

-

-

... More
Supply and fix in replacement MCCB TPN 415 volts 160 Amps 50 Hz Adjustable type, with breaking capacity 25 KA ,complete all as specified and directed.

12

-

-

... More
Taking down XLPE cable and high mast cable from any height of pole and removing the materials from site and making good the disturbed surfaces etc complete all as specified and directed.

2100

-

-

... More
Supply,laying,jointing,testing and commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 16 sqmm 4 core connected with aluminium lugs connected by cramping tools complete all as specified and directed. Note:- Excavation and earth work will be measured and paid separately.

650

-

-

... More
Supply,laying,jointing,testing and commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 25 sqmm 4 core connected with aluminium lugs connected by cramping tools complete all as specified and directed. Note:- Excavation and earth work will be measured and paid separately.

450

-

-

... More
All as per Srl items No.8 here-in-before but of size 50 sqmm x 3.5 core ,complete all as specified and directed.

550

-

-

... More
All as per Srl items No.8 here-in-before but of size 120 sqmm x 3.5 core ,complete all as specified and directed.

450

-

-

... More
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed.

493.5

-

-

... More
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.

180.31

-

-

... More
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.

16800

-

-

... More
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.

197.11

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.

296.39

-

-

... More
M&L for trenchless boring under road crossings/foot paths by manual / Boring machine complete all as specified and directed.

25

-

-

... More
Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed.

55

-

-

... More
Taking down outdoor type LT Panel with by disconnecting all connections very carefully with necessary switchgear deposit to MES store complete all as specified and directed.

1

-

-

... More
Supply and installation testing and and commissioning outdoor LT panel totally enclosed weather and vermin proof, suitably ventilated, 440 Volts, 50HZ,AC supply, fully compartamentalised cubical type made out of 3 mm thick CRCA sheet steel for load bearing and 2.0 mm thick non load bearing portions, protection of enclosure IP-54 as per IS-2147 of 1962 complete with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work/supports, excavation and earth work, PCC foundation etc, including the follwoing switchgear, supplied fitted and connected internally complete with bus bar all as directed :- (a) 4 Nos copper bus bar of equal size of aluminium conductor with PVC coloured heat shrinkable type sleeves contiuous rating 600 Amps with CTs , ammeter and volt meter with selector switches , set of LED type, indicating lamps R,Y,B on incoming side. (b) MCCB TPN, 415 volt adjustable type, 400 Amps with breaking capacity 36 KA- 01 No (Incoming )(Make: L&T/Schnieder/siemens) (c) MCCB TPN 415 volt 250 Amps wirh breaking capacity 36 KA-02Nos (outgoing) (Make: L&T/Schnieder/siemens) (d) MCCB TPN 415 volt 160 Amps wirh breaking capacity 36 KA-03Nos (outgoing) (Make: L&T/Schnieder/siemens) (e) MCB TPN 63 Amps Outgoing

1

-

-

... More
Supply and installation outdoor type loop in loop out junction box totally enclosed double door weather and vermin proof, suitably ventilated, 440 Volts, 50 HZ,AC supply, fully compartamentalised cubical type made out of 3 mm thick CRCA sheet steel and powder coating including suitable angle iron/flat iron frame work/supports, excavation and earth work, PCC foundation etc, including 4 Nos copper bus bar of 200 Amps with indicating lamps of R,Y,B and MCCB TPN, 415 volt adjustable type, 100 Amps with breaking capacity 25 KA- 01 No at incoming side complete all as directed.

5

-

-

... More
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I filling with charcoal dust , and common salt , including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed. Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate.

10

-

-

... More
S&F GI earth strip (32x6) mm strip with and including necessary clamps, nut bolts laid in ground complete all as specified and as directed.

73

-

-

... More
Supply,laying,jointing,testing and commissioning XLPE insulated, armoured, heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 16 sqmm 4 core connected with aluminium lugs connected by cramping , complete all as specified and directed. Note:- Excavation and earth work will be measured and paid separately.

1940

-

-

... More
Supply,laying,jointing,testing and commissioning XLPE insulated, armoured, heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 25 sqmm 4 core connected with aluminium lugs connected by cramping ,complete all as specified and directed. Note :- Excavation and earth work will be measured and paid separately.

950

-

-

... More
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed.

567

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide and depth beyond the first 1.5 mtr for foundation etc. or for shafts, well, cesspits, mainholes etc. in any type of soil for foundation and getting out and levelling of bottom surface to required level ,complete all as specified and directed.

2.16

-

-

... More
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.

226

-

-

... More
Supply and laying unreinforced precast cement concrete cable covers, Class LV, Type-1, with peak, size 250 mm x 150 mm x 40 mm conforming the IS in trenches for cable protection ,complete all as specified and directed.

13066

-

-

... More
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.

245

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.

322

-

-

... More
M&L for trenchless boring under road crossings/foot paths by manual / Boring machine complete all as specified and directed.

40

-

-

... More
Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed.

50

-

-

... More
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggaregate in kerbs/coping /bed plates and like including weathering slightly rounded or chamfered complete with necessary use and waste fo form work complete all as specified and directed.

0.49

-

-

... More
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundation mass concrete and filling including weathering slightly rounded or chamfered complete with necessary use and waste fo form work complete all as specified and directed.

1.35

-

-

... More
Supply and installation outdoor type loop in loop out junction box totally enclosed double door weather and vermin proof, suitably ventilated, 440 Volts, 50 HZ,AC supply, fully compartamentalised cubical type made out of 3 mm thick CRCA sheet steel and powder coating including suitable angle iron/flat iron frame work/supports, excavation and earth work, PCC foundation etc, including 4 Nos copper bus bar of 200 Amps with indicating lamps of R,Y,B and MCCB TPN, 415 volt adjustable type, 100 Amps with breaking capacity 25 KA- 01 No at incoming side complete all as directed and specified.

4

-

-

... More
Supply and installation bus bar chamber factory made (CPRI approvedd) front opeing out door type of size 1.2mx1.2mx0.75m made out of CRCA mild steel surface treated with insulated material polyster or with epoxy phosphatised powder incl. suitale size of copper busbar TPN including porcelain insulator post type braced/ welder with 50 mm angle iron on 4 side and grounted in cement mortar complete all as specified and directed Note : Two Nos danger notice board of size as per IS shall be provided and cost thereof shall be included in quoted rate

2

-

-

... More
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 25x4 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I filling with charcoal dust , and common salt , including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate.

16

-

-

... More
S&F in repair polycarbonate junction loop in / loop out box of internal size 250 x 210 x 115mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular/ PCC pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed.

103

-

-

... More
Supply and fix 1.5 Sqmm, single core Two runs PVC insulated and unsheathed FR cable 1100 Volts grade with multistranded copper conductor and one run of 1.5 Sqmm cable for common earth dolly drawn through heavy duty PVC conduit for street light pole including connection from kiosk box to street light fittings complete all as specified and directed.

150

-

-

... More
Dismantling of ACSR conductor from HT OH lines any size all as directed.

6.4

-

-

... More
Dismantling of LT insulator any type any capacity all as directed.

400

-

-

... More
Dismantling cross- arms of MS ,channel or angle sections & Earth Wire etc complete all as specified and directed.

6.4

-

-

... More
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.