Military Engineer Services Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 58,140Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_667336_2Tender No
8300/3263/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M& L for steel work as in roof trusses (framed), post,trussed, purlins, crane gantries ,rail,rafter, heavy bracket framing (beam, tee, angle, channel or flat sections) distance pieces, cleats,fastening including fabrication and fixing conforming to Fe-410-W(Gde E-250) quality-A complete all as specified & directed. Note: Drawing & design shall be approved by GE.
1500
-
-
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
186
-
-
Dismantling of plain or corrugated steel sheeting (including ridge) any gauge, thickness roof coverings complete all as specified and as directed.
45
-
-
S & F for0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and as directed.
45
-
-
Dismantling of AC/ translucent sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed.
417
-
-
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
373.54
-
-
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of a colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screws complete all as specified and as directed.
44.16
-
-
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust,etc.complete with & including brushing neat cement slurry (@ 3 Kg of cement per Sqm) for bonding of old concrete surface to new concrete, complete all as specified and as directed.
169
-
-
M&L for 75 mm thick plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in PCC flooring finish even and smooth without using extra cement,complete all as specified and directed.
140
-
-
M&L for machine cut kota stone slab flooring 18mm -20 mm thick of size not less than 575 mm X 575 mm, over laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing with Beewax polish over & including 20 mm thick screed bed in CM (1:4) complete all as specifed & directed.
29
-
-
M&L for machine cut kota stone slab in skirtings,riser of steps ,dado & pillar 16 mm to 18 mm thick, laid and jointed with grey cement slurry pointed with cloured cement to match the shade of the slab including grinding rubbing & polishing with Beewax polish over and including 10 mm thick backing coat in CM (1:4) etc complete all as specifed & directed.
3.5
-
-
Taking down cement or cement lime plaster at any position including raking out joints, hacking for key and scrubbing down with water and removal of rubbish off from site complete all as directed by Engr-in-Charge.
463.45
-
-
M&L for 15mm thick rendering (external) on brick or concrete surface in cement mortar 1:4, mixed with & including water proffing compound as per manufacturer instructions finishing surface even and smooth without using extra cement complete all as specified and directed.
177.64
-
-
M&L for 10mm thick rendering (internal) on brick or concrete surface in cement mortar 1:6, finishing surface even and smooth without using extra cement complete all as specified and directed.
293.81
-
-
M&L for preparation of new plastered surfaces of walls using sand paper and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
177.64
-
-
M&L for preparation of newly plastered surface of wall and applying two coats of oil emulsion distemper(OBD) over a coat of alkali resistant primer and a layer of wall care putty (not less than 2.0 mm thick ) to make entire surface free from undulations complete all as specified and directed.
293.81
-
-
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) etc including builders hardware etc & making good disturbed surface of wall with CM 1:3 complete all as specified and directed
15
-
-
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware etc & making good disturbed surface of wall with CM 1:3 complete all as specified and directed
15
-
-
Forming jambs, etc, in CM 1:4 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed
33.68
-
-
S &F powder coated aluminium work for doors, windows, ventilators shutters (fixed /sliding track two or three track) and partitions frames with extruded built up standard sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with sealent with wall, i.e. at top, bottom and sides including cleat angle, C.P. brass/ stainless steel screws, all complete all as specified and directed.
155
-
-
S&F powder coating of any colour (thickness or powder coating not less than 50 micron) anodised , windows, ventilators shutters , fixed type without sash bar ,aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings such as peg stays 150mm long (1No.),100mm long hinges type B-21 (2Nos), suitable handle(02 Nos.) in each door top rail guide rail etc. complete all as specified and directed.
10
-
-
S&F for powder coated aluminium Deco grills size 4mmx4mm, 10mm thick and aperture not exeeding 50 mm X 75 mm width and including fixing with U-aluminium channel, with steel screw and tint match for windows, ventilators etc. with& including aluminium fittings such as locking arrangement complete all as specified and as directed.
42.8
-
-
S &F powder coating aluminium section minimum weight @1.10 Kg/m of any colour for doors, windows, ventilators shutters(fixed/sliding track two or three track) and partitions frames with extruded built up standard sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with sealent with wall, i.e. at top, bottom and sides including cleat angle, C.P. brass/ stainless steel screws,glazing clips rubber neoprene packing, hangles two Nos in each doors ,hinge,aluminium snap beading screws etc , all complete all as specified and directed.
11
-
-
S&F of brass mortice lock, vertical type, size 100 mm long four levers (ISI marked) complete all as specified and directed.
6
-
-
S & F Aluminium anodised handles of extruded section and fixed 150 mm long complete all as specified & directed.
12
-
-
S & F Aluminium anodised barrel tower bolts of extruded section and fixed 150 mm long complete all as specified & directed. .
12
-
-
M & L for 4.0 mm thick plain sheet glass ordinary quality and glazing with oil putty exceeding 0.50 Sqm in each pane,complete all as specified and as directed by Engineer-in-Charge .
13.96
-
-
M & L for 3mm thick plain sheet glass ordinary quality and glazing with oil putty not exceeding 0.50 Sqm in each pane,complete all as specified and as directed by Engineer-in-Charge .
2
-
-
S & F for Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
5
-
-
Dismantling wall and ceiling boarding, any description, fixed in any position with nails/screws complete all as specified and directed.
140
-
-
S & F for providing aluminium snap grid frame work for false ceiling system with size 605 mm x 605 mm, consisting of main runner of size 36.5 mm x 25 mm x 1.4 mm (weight not less than @ 0.24 Kg/Rm) and cross Tee of size 23.5 mm x 36.4 mm x 1.4 mm (weight not less than @ 0.191 Kg/Rm). The snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40 mm X 25 mm X 2 mm (weight not less than @ 0.36 Kg/Rm).The snap grid shall be fixed to ceiling supporting hangers consisting of 2 mm dia mild steel wire /GI wire, J-bolts ,nuts and washers as per manufacturer's instructions and complete all as specified and directed by Engr-in-Charge.
140
-
-
M & L for 4.0 mm thick Non asbestos fibre cement building boards fixed in ceiling flat or sloping fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed by Engr-in-Charge.
140
-
-
M&L for demolition of cement concrete (un reinforced)in ground floor & paving of any thickness (above or below ground level )by mechanical tools and removing excavated material exceeding 1.50 km and not exceeding 5.0 km complete all as specified and directed
3.75
-
-
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed
50
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the all rubbish off from the premises complete all as specified and directed.
356.5
-
-
M&L for coloured ceramic glazed tiles 375x250x7mm/ 450x350x7mm thick, laid in vertical surface as in dado/skirting etc over & including 10 mm thick rendering in CM 1:4, set & jointed in neat cement slurry & pointed in white or coloured cement complete all as specified and directed.
116.5
-
-
M&L for joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc over & including 15mm thick screed bed in CM 1:6, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
7
-
-
M&L for 9-10mm thick coloured vitrified ceramic tiles( dark shade) polished area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm as in floors,set & jointed in neat cement slurry and pointed in coloured cement to match, over & including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
110
-
-
M & L for 9mm to 10mm thick coloured vitrified ceramic tiles( dark shade) polished area of each tiles not exceeding 0.36 sqm ,as in vertical surface such as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles, over & including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
6
-
-
M&L for coloured non digital paver vetrified exterior tiles 10 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.18 sqm in floors etc over & including 15mm thick screed bed in CM 1:6, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
117
-
-
Cutting chases, pinning in to in brick wall , making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth complete all as specified and directed.
13.5
-
-
Taking up or down steel tubing and connections of 15 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed. Note :Cutting chases, pinning in making good to facings where required for concealed water tubing include in unit quoted rate by bidder,not any claim entertained on this account at later stage.
25
-
-
S&F for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick walls for concealed water tubing and making good the surface in cement mortar 1:3 complete all as specified & directed.
25
-
-
S & F in repair vitreous China wash basin, any colour, flat back size 550 mm X 400 mm including 32mm brass chromium plated waste coupling , 32 mm bore PVC waste pipe, chromium plated Grating including cutting for & pinning in ends of bracket or errecting bracket & PCC 1:2:4 ,type B-1(using 20 mm graded crushed stone aggregate) for embedding brackets & making good disturbed surface with CM 1:3 complete all as specified and directed.
1
-
-
S & F vitreous China angle back of size 430mm X370 mm X340 mm (minimum) urinals with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)(back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe etc.complete all as specified and as directed
1
-
-
S&F WC squatting pan " Orissa Pattern" of size 580 mm X 440 mm white with integral foot rest including cast iron "P" or "S" trap, front or back inlet and making connection to trap & to flushing cistern complete including taking down existing pan & making good disturbed surface complete all as specified & directed.
1
-
-
S & F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including all standard accessories such as inlet ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set & making good disturbed surface with CM 1:3 complete all as specified and directed.
1
-
-
S&F in repair stop cock 15mm bore chromium plated with long shank fancy type cast copper alloy, screwed down high pressure, screwed both ends for iron pipe or for brass ferrule fixed concealed in wall etc complete all as specified and directed.
6
-
-
S&F in repair 15mm bore long body (weight not less than 400 gm) bib tap, cast copper alloy, CP fancy type with crutch or butterfly handle, screw down, screwed for iron pipe or for brass ferrule including flange complete all as specified and directed
1
-
-
S&F in repair pillar taps fancy type, cast copper alloy with capstan head, chromium plated, screwed down with or without lettered 'Hot' or 'Cold' with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed.
1
-
-
S & F in repair Grating doom 100mm dia of PTMT (minimum weight 25gms) complete all as specified and directed by Engineer-in- Charge.
2
-
-
S&F in repair for PVC connection 15 mm dia size with PTMT nuts of length 450 mm complete all as specified and directed.
3
-
-
S&F in repair for towel rail aluminium anodised towel rail , 20 mm dia 600 mm long between bracket ,fixed with and including chromium plated brass screw & wooden /plastic cleats complete set all as specified and directed.
1
-
-
S&F in repair for chromium plated soap tray of size 160 mm X 160 mm X 90 mm fixed with brass screw & wooden /plastic cleats complete set all as specified and directed.
1
-
-
S&F in repair PVC flexible waste pipe of dia 32 mm fixed to WHB etc complete 32mm all as specified and as directed.
2
-
-
S & F 110 mm dia PVC(SWR) WC connector with lip ring, complete all as directed and as specified.
1
-
-
S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf, 12cm wide with chromium plated bracket guard and railing 60cm long complete set complete all as specified and directed.
1
-
-
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces and apply two coats of distemper oil emulsion (OBD) over a coat of alkali resistant primer and a layer of wall care putty (not less than 2.0 mm thick ) complete all as specified and directed.
160
-
-
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces of wall and applying two or more coats of acrylic smooth exterior paint of required shade new work (two or more coats applied @ 1.67 Ltr/10 Sqm and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm complete all as specified and directed.
45
-
-
S&F 5.5 mm thick glass sheet is ground or obscured or frosted glass pin headed type in squares/ rectangular exceeding 0.5 Sqm in each pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete all as specified & directed.
10.8
-
-
M&L for 18 to 20 mm thick granite slab (or any type) table rubbed and pre mirror polished in steps,jambs, pillar,window cill,cooking platforms and like in cement mortar1:4, set & jointed in neat cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and polished , over & including 15 mm thick rendering in cement mortar(1:4) etc including dismantling of exsting slab complete all as specifed and as directed.
8
-
-
S&F for two way surgical Scrub sink 1500mm length and width 600mm-800mm, height 800mm-900mm as suitable at user requirement . Double Bay Scrub Station is attached with infrared photo sensor Digital timer has defined timer interval 1,3,5 and 10 minutes. 2 No. Mixture valve and 3 Nos. Solenoid valves are provided along with manual option foot/knees operated mechanism. The Anti-splash metal body, corrosion resistance and easy cleaning, construction is made of stainless steel 304 Grade with polished finished thickness 1.5mm. The Scrub Station Double Tap is provided with front access panel. Size: 1500x600x800 mm User: Two Tap : Foot/Sensor Operated
1
-
-
S&F for Hermetically sealed manual siding hoispital door (Nexon) 1500 x 2000mm, track high grade aluminium extrusion profile to carry any door weight, door core of 60mm thick surrounded by 2.5mm thick high grade aluminium extrusion profile with netural anodising of 1.5 microns finish, gaskets with stainless steel nexon lever handle on both side to easy door opening and closing, using high quality double glazed flush vision window of 300mm x300mm view size, sound reducing door upto 28 db suitable for operation theaters incl stainless steel guard column of 100mm dia with 8mm heavy base plate at both side fo free passage to protect door from moving medical equipment and trolleys etc all as specified.
2
-
-
S&F for Hermetically sealed manual siding hospital door (Nexon) 1200 x2000mm track high grade aluminium extrusion profile to carry and door weight, door core of 60mm thick surrounded by 2.5mm thick high grade aluminium extrusion profile with netural anodising of 1.5 microns finish, gaskets with stainless steel nexon lever handle on both side to easy door opening and closing, using high quality double glazed flush vision window of 300mm x 300mm view size, sound reducing door upto 28 db suitable for operation theaters incl stainless steel guard column of 100mm dia with 8mm heavy base plate at both side of free passage to protect door from moving medical equipment and trolleys etc all as specified.
2
-
-
Taking down carefully unserveciable/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets ,light fittings etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
66
-
-
M & L for point wiring for one light/exhaust fan point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc.,including cutting holes for sitches,sockets, regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note : Proper colour coding to be adopted & making good disturb surface with cement motrar with 1:4 or to match with existing finishes.
37
-
-
All as per item No .69 here-in-before but 3 pin socket outlet 5 Amp socket outlet on same board. Controlled by one, one way switch
5
-
-
All as per item No .69 here-in-before but 3/5 pin socket outlet 5 Amp socket outlet on independent board.
7
-
-
M&L for point wiring FRLSH cable PVC for 5 amp /15 amp 3 pin socket power point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 2.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall & 2.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc., including cutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note : Proper colour coding to be adopted & making good disturb surface with cement motrar with 1:4 or to match with existing finishes.
17
-
-
S & F switch piano flush button single pole one way 5 Amp complete all as specified and as directed.
42
-
-
S & F socket outlet polycarbonate 2 in 1, 3 pin, 5Amp flush type, universal, complete all as specified & as directed
5
-
-
S & F Switch socket combination 2 in 1, 3 pin, 5Amp flush type, universal, complete all as specified & as directed
7
-
-
S & F Switch socket combination 2 in 1, 3 pin, 5Amp & 15/16 Amp, flush type, universal, complete all as specified.
17
-
-
S&F fan regulator electronic, step type hum free, socket type, suitable for ceiling fans of any capacity, pre wired 230 volts AC 50 HZ supply 100/120 Watt complete all as specified & as directed
4
-
-
S & F ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified & as directed
33
-
-
S & F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked), complete all as specified.
6
-
-
S & F in repair sheet metal enclosures for DBs when MCBs to be used in tipple pole and neutral (TPN) double door 415 volts, 4 way, with magnetic locking system including necessary provision for inserting the the DBs in wall & suitable rated amp bus bar and neutral link (ISI marked) complete all as specified and as directed.
1
-
-
S & F in repair sheet metal enclosures for DBs when MCBs to be used in single pole and neutral (SPN) double door 240 volts, 8 way, with magnetic locking system including necessary provision for inserting the the DBs in wall & suitable rated amp bus bar and neutral link (ISI marked) complete all as specified and as directed.
4
-
-
S&F miniature circuit breaker (MCB) 415 V , breaking capacity 10 KA, 'C' curve of TPN/FP ( tripple poles and neutral/four pole) and current carrying capacity 100 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
1
-
-
S&F in repair miniature circuit breaker (MCB) 240V, braking capacity 10 KA ,'C' curve of single poles and neutral and current carrying capacity 32amp/40 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
4
-
-
S&F 240V 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
42
-
-
M & L Sub main wiring with two runs of single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 25 mm dia/appropriate dia with accessories & fittings complete and making good disturbed surface wall including taking down existing sub main wiring complete all as specified and as directed. Note : - Two runs of 6.0 Sqmm cable and one run of earth wire 6.0 sqmm & conduit shall be measured as one unit length and extra length of cable required for connection to MCBs shall be deemed to be include in unit rate quoted by bidder.
70
-
-
Supply, laying ,jointing and testing LT cable, XLPE Insulated ,armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq.mm.,4.0 core including taking down of existing cable complete all as specified & directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item, if required. (2) All Necessary T & P required shall be arranged by the Contractor.
60
-
-
Supply, laying ,jointing and testing LT cable, XLPE Insulated ,armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq.mm.,2.0 core complete all as specified & directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item. (2) All Necessary T & P required shall be arranged by the Contractor.
60
-
-
Supply and spreading clean, dry, fine river sand for under ground(UG) electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
13.37
-
-
Supplying & Laying un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
990
-
-
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh, charcoal & salt, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally & angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including making good disturbed surface of wall ,floors etc.including taking down/dismantling of existing earthing complete all as directed.
Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre.
(ii) Earth filling shall be done by vegetable soil.
(iii) Soil should be free from stone, boulders, aggregate, gravels etc.
4
-
-
Excavation in trenches in soft/loose of soil not exceeding 0.45 metre deep and not exceeding 0.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed.
35.56
-
-
Returning, filling in, including spreading, levelling, watering & well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
21.33
-
-
Removing excavated soil not exceeding 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
14.22
-
-
Supply and laying for 40 mm dia HDPE pipe of pressure rating 6 Kgf/sq.cm fixed with all necessary fittings for cable protection in walls, ceiling, floors, road etc complete all as specified and directed by Engineer-in-Charge.
12
-
-
Taking down ceiling fan/exhaust fan of any sweep after disconnecting all necessary electrical connctions from ceiling rose to fan complete all as specified and directed.
4
-
-
Labour only for the refixing ceiling fan/exhaust fan after servicing /repairing/overhauling by cleaning/greasing /oiling etc. including provision of connecting ceiling fan/exhaust fan to ceiling rose including three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection and preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying one coat of synthetic enamel (white shade) paint and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-charge.
4
-
-
Supply, installation, commissioning and testing Split type wall mounted Air Conditioner, electric driven, single phase, 230 Volts, 50 Hz of capacity 2.0 TR with high efficiency rotary type sealed compressor unit complete with PCB board and with cordless remote control unit operation system with refrigerant gas,BEE minimum 4 star rating, EER 3.2,AC supply complete including copper pipe insulation etc and above complete all as specified and directed with comprising of following .:- (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water.
(b) Out door unit comprising of Compressor with motor, air cooled copper condenser with fan and motor unit shall be installed out side the building/ on roof.
(c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable.
(d) Making good the disturbed surface to match the existing surface after plugging the hole etc.
(e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly 2.0 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer shall in quoted rate under this item.
Make: Blue star/Daikin/Hitchi/Carrier
2
-
-
Supply , installation/ fix for 5 KVA capacity Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and as directed.
Make: V-Guard/Crompton/Usha/Bajaj
2
-
-
S & F sheet metal enclosures with socket plug top and MCBs having single pole and nutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp ,"C" series, breaking capacity 10 KA, 240 V complete all as specified and as directed.
2
-
-
M & L for sub main wiring with Two RUNS of single core 4 Sq.mm for main wire and one run of single core 4 Sq.mm as earth wire of multi stranded copper conductor FRLSH PVC insulated unsheathed cable conforming to IS : 694 drawn through and including concealed in PVC coduit conforming to IS : 9537 ( Part-3) and ISI marked not lass than 25 mm dia medium grade and all accessories conforming to IS specification complete all as specified and directed.
Note:- Two runs of 4 Sqmm cable, one run of earth wire 4 Sqmm and one run of conduit shall be measured as one unit length & extra length of cable required for connectrion to MCB shall be deemed to be include the unit quoted rate by bidder
40
-
-
S & F sheet metal enclosures for DBs when MCBs to be used in single pole and neutral (SPN) double door 240 volts, 4 way, with magnetic locking system including necessary provision for inserting the the DBs in wall & suitable rated amp bus bar and neutral link (ISI marked) complete all as specified and as directed.
1
-
-
Supply and fixing miniature circuit breaker (MCB) of single poles and neutral (SPN), 'C' Curve, 240 Volt, breaking capacity 10 KA and current carrying capacity 63A Amp in the MCB DB with connection testing and commissioning complete all as specified and as directed.
2
-
-
Supply, laying , jointing & testing 1100 Volt XLPE insulated,screened ,PVC bedded, galvanised steel strip or wire armoured, electirc power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 10 Sq mm 2.0 core complete all as specified and directed.
90
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%